PROTECTOR® SERIES
Standby Generators Liquid-Cooled Gaseous Engine
Protector ® Series
Protector® Series
1 of 11
Standby Power Rating
INCLUDES: • Two Line LCD Multilingual Digital Evolution™ Controller (English/Spanish/French/Portuguese) with external viewing window for easy indication of generator status and breaker position.
Model RG025 (Aluminum - Bisque) - 25 kW 60 Hz Model RG030 (Aluminum - Bisque) - 30 kW 60 Hz Model RG036 (Aluminum - Bisque) - 36 kW 60 Hz Model RG045 (Aluminum - Bisque) - 45 kW 60 Hz Model RG060 (Aluminum - Bisque) - 60 kW 60 Hz
• Capability to be installed with 18" (457mm) of a building* • True Power™ Electrical Technology • Isochronous Electronic Governor • Sound Attenuated Enclosure • Closed Coolant Recovery System • Smart Battery Charger • UV/Ozone Resistant Hoses • ±1% Voltage Regulation • Natural Gas or LP Operation • 5 Year Limited Warranty • UL 2200 Listed
*Built in the USA using domestic and foreign parts
Note: 25-45 kW units are field convertible between natural gas or liquid propane. 60 kW units are built per fuel requirement and are not convertible.
*Only if located away from doors, windows, and fresh air intakes, and unless otherwise directed by local codes. Applicable for 25kW and 30kW units only.
Meets EPA Emission Regulations 25, 30 & 45 kW CA/MA emissions compliant 36 & 60 kW not for sale in CA / MA
FEATURES ¡ INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC’S success in “IMPROVING POWER BY DESIGN.” But it doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance.
¡ TEST CRITERIA: a PROTOTYPE TESTED a SYSTEM TORSIONAL TESTED
a NEMA MG1-22 EVALUATION a MOTOR STARTING ABILITY
¡ SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. Digital voltage regulation at ±1%. ¡ SINGLE SOURCE SERVICE RESPONSE from Generac’s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. ¡ G ENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility.
ISO 9 0 0 1: 2008
Protector ® Series 2 of 11
25 • 30 • 36 • 45 • 60 kW
application & engineering data
GENERATOR SPECIFICATIONS
ENGINE SPECIFICATIONS: 25 & 30 kW
Type
Synchronous
Make
Rotor Insulation Class
H
Model
Stator Insulation Class
H
Cylinders
Telephone Interference Factor (TIF)
<50
Generac In-line 4
Displacement (Liters)
1.5
Alternator Output Leads 1-Phase
4 wire
Bore (in/mm)
3.05/77.4
Alternator Output Leads 3-Phase
6 wire
Stroke (in/mm)
3.13/79.5
Bearings
Sealed Ball
Compression Ratio
Coupling
Flexible Disc
Intake Air System
Excitation System
Direct
VOLTAGE REGULATION
Lifter Type
Hydraulic
ENGINE SPECIFICATIONS: 36, 45 & 60 kW
Type
Electronic
Sensing
Single Phase
Regulation
± 1%
Make Model Cylinders Displacement (Liters)
GOVERNOR SPECIFICATIONS Type
Electronic
Frequency Regulation
Isochronous
Steady State Regulation
± 0.25%
12 Volt 15 Amp - 25 & 30 kW 12 Volt 30 Amp - 36, 45 & 60 kW
Static Battery Charger
2 Amp
Recommended Battery (battery not included)
Group 26, 525CCA
System Voltage
12 Volts
GENERATOR FEATURES Revolving field heavy duty generator Directly connected to the engine Operating temperature rise 120 °C above a 40 °C ambient Class H insulation is NEMA rated All models fully prototyped tested
ENCLOSURE FEATURES
In-line 4 2.4 3.41/86.5
Stroke (in/mm)
3.94/100
Compression Ratio
Lifter Type
9.5:1 Naturally Aspirated (36 & 45 kW) or Turbocharged/Aftercooled (60 kW) Hydraulic
ENGINE LUBRICATION SYSTEM Oil Pump Type
Gear
Oil Filter Type
Full flow spin-on cartridge
Crankcase Capacity (qt/l)
4/3.8 - 25, 30, 36 & 45 kW 5.25/4.96 - 60 kW
ENGINE COOLING SYSTEM Type Water Pump Fan Speed (rpm)
Aluminum weather protective enclosure
Ensures protection against mother nature. Electrostatically applied textured epoxy paint for added durability.
Fan Diameter (in/mm)
Enclosed critical grade muffler
Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
Fan Mode
Small, compact, attractive
Makes for an easy, eye appealing installation.
SAE
Sound attenuated enclosure ensures quiet operation.
Closed Belt driven 2484 - 25 & 30 kW 1865 - 36 & 45 kW 2100 - 60 kW 17.7/449.6 (25 & 30 kW) or 22/558.8 (36, 45 & 60 kW) Pusher (25 & 30 kW) or Puller (36, 45 & 60 kW)
FUEL SYSTEM Fuel Type Carburetor
Natural gas, propane vapor Down Draft
Secondary Fuel Regulator
Standard
Fuel Shut Off Solenoid
Standard
Operating Fuel Pressure
(All ratings in accordance with BS5514, ISO3046, ISO8528, SAE J1349 and DIN6271)
Generac
Bore (in/mm)
Intake Air System
ELECTRICAL SYSTEM Battery Charge Alternator
11:1 Naturally Aspirated
5-14" water column/9-26 mm HG
LP Fuel Pressure
11 - 14" Water Column
NG Fuel Pressure
5 - 14" Water Column
operating data
GENERATOR OUTPUT VOLTAGE/kW - 60 Hz
RG025
RG030
RG036
RG045
RG060
kW LPG
Amp LPG
kW Nat. Gas
Amp Nat. Gas
CB Size (Both)
120/240 V, 1Ø, 1.0 pf
25
104
25
104
125
120/208 V, 3Ø, 0.8 pf
25
87
25
87
100
120/240 V, 3Ø, 0.8 pf
25
75
25
75
90
120/240 V, 1Ø, 1.0 pf
30
125
30
125
150
120/208 V, 3Ø, 0.8 pf
30
104
30
104
125
120/240 V, 3Ø, 0.8 pf
30
90
30
90
100
120/240 V, 1Ø, 1.0 pf
36
150
36
150
175
120/208 V, 3Ø, 0.8 pf
36
125
36
125
150
120/240 V, 3Ø, 0.8 pf
36
108
36
108
125
277/480 V, 3Ø, 0.8 pf
36
54
36
54
60
120/240 V, 1Ø, 1.0 pf
45
188
45
188
200
120/208 V, 3Ø, 0.8 pf
45
156
45
156
175
120/240 V, 3Ø, 0.8 pf
45
135
45
135
150
277/480 V, 3Ø, 0.8 pf
45
68
45
68
80
120/240 V, 1Ø, 1.0 pf
60
250
60
250
300
120/208 V, 3Ø, 0.8 pf
60
208
60
208
250
120/240 V, 3Ø, 0.8 pf
60
180
60
180
200
277/480 V, 3Ø, 0.8 pf
60
90
60
90
100
SURGE CAPACITY IN AMPS
RG025
RG030
RG036
RG045
RG060
3 of 11
ENGINE FUEL CONSUMPTION Voltage Dip @ < .4 pf 15%
30%
120/240 V, 1Ø
65
170
120/208 V, 3Ø
80
130
120/240 V, 3Ø
69
112
120/240 V, 1Ø
75
120/208 V, 3Ø 120/240 V, 3Ø
Natural Gas
Propane
(ft³/hr)
(m³ /hr)
(gal/hr)
(l/hr)
(ft³/hr)
22
0.6
0.2
0.8
8.0
25% of rated load
93
2.6
0.7
2.8
27
50% of rated load
140
4
1.2
4.8
45
180
75% of rated load
180
5.1
1.7
6.4
60
96
155
100% of rated load
221
6.3
2.1
7.9
75
83
134
Exercise cycle
22
0.6
0.2
0.8
8.0
120/240 V, 1Ø
105
240
25% of rated load
93
2.6
0.7
2.8
27
120/208 V, 3Ø
44
130
50% of rated load
140
4
1.2
4.8
45
120/240 V, 3Ø
38
115
75% of rated load
180
5.1
1.7
6.5
60
277/480 V, 3Ø
20
60
100% of rated load
221
6.3
2.1
7.9
75
120/240 V, 1Ø
105
240
Exercise cycle
63
1.8
0.6
2.5
23
120/208 V, 3Ø
44
130
25% of rated load
194
5.5
2.2
8.3
78
120/240 V, 3Ø
38
115
50% of rated load
332
9.4
3.5
13.6
179
277/480 V, 3Ø
20
60
75% of rated load
479
13
5
18
216
120/240 V, 1Ø
140
320
100% of rated load
626
17
6.4
24
231
120/208 V, 3Ø
70
210
Exercise cycle
83
2.2
0.8
3.1
30
120/240 V, 3Ø
61
182
25% of rated load
315
8.9
3.1
11.7
111
277/480 V, 3Ø
30
91
50% of rated load
501
14
5
18.8
177.7
75% of rated load
692
19.6
7
26
249
100% of rated load
836
23.7
8.6
32.7
309.5
Exercise cycle RG025
RG030
RG036
RG045
Note: Fuel pipe must be sized for full load.
Exercise cycle
105
2.9
1.1
4.2
40
For Btu content, multiply ft³/hr x 2520 (LP) or ft³/hr x 1000 (NG)
25% of rated load
390.6
11
4
15
143.5
50% of rated load
610.8
17
6.5
24.5
231.6
For megajoule content, multiply m³/hr x 93.15 (LP) or m³/hr x 37.26 (NG) Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCAQMD permitting purposes.
RG060
Protector ® Series
25 • 30 • 36 • 45 • 60 kW
75% of rated load
824
23
8.8
33
314
100% of rated load
1051
29.8
11
42
400
STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice.
Protector ® Series
25 • 30 • 36 • 45 • 60 kW ENGINE COOLING Air flow (inlet air including alternator and combustion air in cfm/cmm)
4 of 11
operating data
System coolant capacity (gal/liters) Heat rejection to coolant (BTU per hr/MJ per hr)
25 kW
30 kW
36 kW
45 kW
60 kW
2490/70.5
2490/70.5
2725/77.2
2725/77.2
3280/92.9
2/7.6
2/7.6
2.5/9.5
2.5/9.5
2.5/9.5
112,000/118.2
135,000/142.4
193,000/203.6
193,000/203.6
270,000/284.9
Maximum operation air temperature on radiator (°C/°F)
60/140
Maximum ambient temperature (°C/°F)
50/122
COMBUSTION REQUIREMENTS Flow at rated power (cfm/cmm)
62/1.8
72/2
144/4.1
144/4.1
180/5.1
Sound output in dB(A) at 23 ft (7 m) with generator in exercise mode*
59
59
61
61
65
Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load*
72
73
70
73
72
SOUND EMISSIONS
*Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters.
EXHAUST Exhaust flow at rated output (cfm/cmm) Exhaust temperature at muffler outlet (°C/°F)
203/5.7
237/6.7
300/8.5
420/11.9
494/14
593/1100
610/1130
579/1075
593/1100
566/1050
ENGINE PARAMETERS Rated Synchronous rpm
3600
POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration............................................................................................................3% for every 10 °C above 25 °C or 1.65% for every 10 °F above 77 °F Altitude Deration (25, 30, 36 & 45 kW)................................................................................1% for every 100 m above 183 m or 3% for every 1000 ft above 600 ft Altitude Deration (60 kW) ................................................................................................. 1% for every 100 m above 915 m or 3% for every 1000 ft above 3000 ft
CONTROLLER FEATURES 2-Line Plain Text LCD Display.........................................................................................................................................Simple user interface for ease of operation. Mode Switch: Auto ...............................................................................................................................................Automatic Start on Utility failure. 7 day exerciser Off............................................................................................................................Stops unit. Power is removed. Control and charger still operate. Manual.......................................................................................... Start with starter control, unit stays on. If utility fails, transfer to load takes place. Programmable start delay between 10-30 seconds............................................................................................................................................................. Standard Engine Start Sequence...................................................................................................................... Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration) Engine Warm-up...................................................................................................................................................................................................................... 5 sec Engine Cool-Down...................................................................................................................................................................................................................1 min Starter Lock-out.................................................................................................................................Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger......................................................................................................................................................................................................... Standard Automatic Voltage Regulation with Over and Under Voltage Protection................................................................................................................................. Standard Automatic Low Oil Pressure Shutdown................................................................................................................................................................................ Standard Overspeed Shutdown............................................................................................................................................................................................... Standard, 72 Hz High Temperature Shutdown................................................................................................................................................................................................ Standard Overcrank Protection........................................................................................................................................................................................................... Standard Safety Fused....................................................................................................................................................................................................................... Standard Failure to Transfer Protection............................................................................................................................................................................................... Standard Low Battery Protection......................................................................................................................................................................................................... Standard 50 Event Run Log................................................................................................................................................................................................................ Standard Future Set Capable Exerciser............................................................................................................................................................................................... Standard Incorrect Wiring Protection.................................................................................................................................................................................................. Standard Internal Fault Protection...................................................................................................................................................................................................... Standard Common External Fault Capability....................................................................................................................................................................................... Standard Governor Failure Protection................................................................................................................................................................................................. Standard
Model #
G006463-4
available accessories
Product
Description
Mobile Link™
Generac's Mobile Link allows you to check the status of your generator from anywhere that you have access to an Internet connection from a PC or with any smart device. You will even be notified when a change in the generator’s status occurs via e-mail or text message. Note: Harness Adapter Kit required. Available in the U.S. only.
Harness Adapter Kit
The Harness Adapter Kit is required to make liquid-cooled units compatible with Mobile Link™.
Cold Weather Kit
If the temperature regularly falls below 32 °F (0 °C), install a cold weather kit to maintain optimal battery temperature. Kit consists of battery warmer with thermostat built into the wrap.
G005616-0 - 36, 45 & 60 kW
Extreme Cold Weather Kit
Recommended where the temperature regularly falls below 32 °F (0 °C) for extended periods of time. For liquid cooled units only.
G005651-0
Base Plug Kit
Add base plugs to the base of the generator to keep out debris.
G005703-0 - Bisque
Paint Kit
If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure.
Scheduled Maintenance Kit
The Liquid-Cooled Scheduled Maintenance Kits offer all the hardware necessary to perform complete maintenance on Generac liquid-cooled generators.
G006664-0
Local Wireless Monitor
Completely wireless and battery powered, Generac's wireless remote monitor provides you with instant status information without ever going outside.
G006665-0
Wireless Remote Extension Harness
Recommended for use with the Wireless Remote on units up to 60 kW, required for use on units 70 kW or greater.
G006873-0
Smart Management Module (50 Amps)
Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its power management capabilities. It provides additional power management flexibility not found in any other power management system.
G006510-0
E-Stop
E-stop allows for immediate fuel shutoff and generator shutdown in the event of an emergency.
G006478-0
G006175-0 - 25 & 30 kW G005630-1 - 36, 45 & 60 kW G006174-0 - 25 & 30 kW
G006176-0 - 25 & 30 kW G006172-0 - 36 & 45 kW G006171-0 - 60 kW
Protector ® Series
25 • 30 • 36 • 45 • 60 kW
5 of 11
LEFT SIDE VIEW
TOP VIEW
RADIATOR/EXHAUST DISCHARGE AIR (BOTH SIDES)
EXHAUST MUFFLER ENCLOSED WITHIN GENERATOR ENCLOSURE
RADIATOR/EXHAUST DISCHARGE AIR
REMOVE COVER FOR ACCESS TO RADIATOR FILL CAP
BATTERY 12V GROUP 26 NEGATIVE GROUND P/N: 077483
RIGHT DOOR RIGHT DOOR
OIL FILTER OIL DRAIN HOSE RADIATOR DRAIN HOSE RIGHT DOOR
RIGHT DOOR
OIL FILL CAP OIL DIP STICK
RIGHT DOOR
FAN BELT BATTERY
ENCLOSURE MATERIAL ST ST AL AL
1.5L/25KW 1.5L/30KW 1.5L/25KW 1.5L/30KW
366 [807]
352 [777]
406 [895]
392 [865]
WEIGHT GENSET ONLY KG [LBS]
WEIGHT DATA
LIFTING PROVISION (4 PLACES) SEE NOTES 5, 8 AND CENTER OF GRAVITY DIMENSIONS.
978 (38.5) OVERALL HEIGHT
30 [66]
30 [66]
30 [66]
30 [66]
WEIGHT SHIPPING SKID KG [LBS]
396 [873]
382 [843]
436 [961]
422 [931]
48 (1.8)
Drawing #0K8420-B (1 of 2)
47.6 (2.9)
783 (30.7)
VISE ACTION LATCH, ONE PER DOOR, ONE LIFT-OFF DOOR PER SIDE OF GENERATOR.
RIGHT SIDE VIEW
1490 (57.6)
630 (24.8) DOOR TYP
FUEL LINE CONNECTION 3/4" NPT FEMALE COUPLING
44 (1.7)
1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1092 (43") WIDE X 1887 (74.3") LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: - SEE SPECIFICATION SHEET OR OWNERS MANUAL - ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS THE STUB-UP AREAS AS FOLLOWS: - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. - LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7. EXHAUST SYSTEM MAXIMUM BACK PRESSURE: 24 INCHES H2O. 8. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 9. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 10. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 11. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. 12. EXHAUST MUFFLER ENCLOSED WITHIN GENERATOR ENCLOSURE, REMOVE ENCLOSURE TO ACCESS EXHAUST MUFFLER.
NOTES:
CIRCUIT BREAKER NEUTRAL AND CUSTOMER CONNECTION OPENING
DIMENSIONS: MM [INCH]
CUSTOMER ACCESS ASSEMBLY, CONTROL PANEL ACCESS, BATTERY CHARGER LOCATED WITHIN SEE NOTE 4
CIRCUIT BREAKER SEE NOTE 3
REAR ENCLOSURE COVER PANEL SEE NOTE 4
SHIPPING WEIGHT KG [LBS]
REAR VIEW
EITHER DOOR
MUFFLER
REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS.
RIGHT DOOR SEE NOTE 12
SPARK PLUGS
AIR CLEANER ELEMENT RIGHT DOOR
ENGINE/KW
665.5 [26.2"] CENTER OF GRAVITY (SEE NOTE 5)
1.5L EITHER DOOR
SERVICE ITEM
6 of 11
AIR INTAKE (BOTH SIDES)
Protector ® Series
25 & 30 kW installation layout
45 (1.8) TYP
13.5 X 29.5 MOUNTING SLOTS 4X
LEFT SIDE VIEW
1580 (62.2)
1345 (60.8)
TOP VIEW
1380 (54.3) TYP MOUNTING SLOT CENTERS
50 (1.9)
226 (8.9)
100 (3.9) STUB-UP AREA
51 (2.0)
DIMENSIONS: MM [INCH]
9 (.4)
104.5 (4.1) STUB-UP AREA
27 (1.0) TYP
674 (26.5)
REAR VIEW
776 (30.6)
723 (28.5) TYP MOUNTING SLOT CENTERS
735 (28.9)
installation layout Drawing #0K8420-B (2 of 2)
Protector ® Series
REMOVABLE STUB-UP COVER
96 (3.8)
*NOTE - STUB-UP AREA FOR HIGH AND LOW VOLTAGE CONNECTIONS. CIRCUIT BREAKER, NEUTRAL AND CUSTOMER CONNECTION OPENING.
25 & 30 kW
7 of 11
187 [7.4]
RADIATOR/EXHAUST DISCHARGE AIR
EXHAUST MUFFLER ENCLOSED WITHIN GENERATOR ENCLOSURE
443 [17.5]
AL ST AL
2.4L 45KW 2.4L 60KW 2.4L 60KW
AL ST
ST
2.4L 45KW
2.4L 36KW 2.4L 36KW
ENCLOSURE MATERIAL
ENGINE/KW
WEIGHT DATA
558 [1230]
582 [1283]
572 [1260]
596 [1313]
545 [1202]
569 [1255]
WEIGHT GENSET ONLY KG [LBS]
1170 [46.1] OVERALL HEIGHT
44 [98]
44 [98]
44 [98]
44 [98]
44 [98]
44 [98]
WEIGHT SHIPPING SKID KG [LBS]
888 [35.0] OVERALL WIDTH REAR VIEW
REMOVE COVER FOR ACCESS TO LUBE OIL MAINTAINER SUPPLY TANK REFERENCE OWNERS MANUAL
REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS.
LEFT SIDE ROOF TOP
BATTERY LUBE OIL MAINTAINER SUPPLY TANK FILL CAP
CIRCUIT BREAKER SEE NOTE 3
749.3 [29.5] CENTER OF GRAVITY (SEE NOTE 5)
DRIVE BELT SEE NOTE 11
EITHER SIDE
MUFFLER FAN BELT
LEFT SIDE SEE NOTE 11
SPARK PLUGS
LEFT SIDE
LEFT SIDE
AIR CLEANER ELEMENT
LEFT SIDE ROOF TOP
RADIATOR FILL CAP
RADIATOR DRAIN HOSE
RIGHT SIDE
RIGHT SIDE
OIL FILTER OIL DRAIN HOSE
OIL DIP STICK
COOLANT RECOVERY BOTTLE
50 1000 [39.4] [2.0] FUEL LINE CONNECTION LEFT SIDE VIEW 3/4" NPT FEMALE COUPLING
BATTERY 12V GROUP 26 NEGATIVE GROUND P/N: 077483 TOP VIEW
REMOVE COVER FOR ACCESS TO RADIATOR FILL CAP
AIR INTAKE (BOTH SIDES)
RIGHT SIDE
OIL FILL CAP
Drawing #0K8636-B (1 of 2)
58 [2.3] TYP
602 [1328]
626 [1381]
616 [1358]
640 [1411]
590 [1300]
613 [1353]
SHIPPING WEIGHT KG [LBS]
DIMENSIONS: MM [INCH]
CUSTOMER ACCESS ASSEMBLY, CONTROL PANEL ACCESS, BATTERY CHARGER 46.5 LOCATED WITHIN [1.83] SEE NOTE 4
REAR ENCLOSURE COVER PANEL SEE NOTE 4
1950 [76.8] OVERALL LENGTH RIGHT SIDE VIEW
1857 [73.1] TYP
1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194MM (47") WIDE X 2256MM (88.8") LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: - SEE SPECIFICATION SHEET OR OWNERS MANUAL - ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS THE STUB-UP AREAS AS FOLLOWS: - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. - LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. 11. EXHAUST MUFFLER AND FAN BELT ENCLOSED WITHIN GENERATOR ENCLOSURE, VICE ACTION LATCH, REMOVE FRONT PANEL TO ACCESS. ONE PER DOOR, ONE LIFT OFF DOOR PER SIDE 758 [29.8] OF GENERATOR DOOR TYP
NOTES:
8 of 11
RADIATOR/EXHAUST DISCHARGE AIR (BOTH SIDES)
2.4L EITHER SIDE
SERVICE ITEM
Protector ® Series
36 & 45 kW installation layout
50 [2.0] TYP
13.5 X 29.5 MOUNTING SLOTS 4X
LEFT SIDE VIEW
1950 [76.8]
1750 [68.9] TYP MOUNTING SLOT CENTERS
TOP VIEW
1733 [68.2]
12 [.5]
217 [8.5]
DIMENSIONS: MM [INCH]
25 [1.0] TYP
162 [6.4] *STUB-UP AREA
9 [.4]
162 [6.4] *STUB-UP AREA
850 [33.5]
REAR VIEW
888 [35.0]
838 [33.0] TYP MOUNTING SLOT CENTERS
51 [2.0]
786 [30.9]
installation layout Drawing #0K8636-B (2 of 2)
Protector ® Series
116 [4.6]
REMOVABLE STUB-UP COVER
*NOTE - STUB-UP AREA FOR HIGH AND LOW VOLTAGE CONNECTIONS. CIRCUIT BREAKER, NEUTRAL AND CUSTOMER CONNECTION OPENINGS.
36 & 45 kW
9 of 11
RADIATOR/EXHAUST DISCHARGE AIR
EXHAUST MUFFLER ENCLOSED WITHIN GENERATOR ENCLOSURE
TOP VIEW
DRIVE BELT
ENCLOSURE MATERIAL ST AL
ENGINE/KW 2.4L 60KW 2.4L 60KW
WEIGHT DATA
582 [1283] 558 [1230]
44 [98]
44 [98]
WEIGHT SHIPPING SKID KG [LBS]
REAR VIEW
888 [35.0] OVERALL WIDTH
WEIGHT GENSET ONLY KG [LBS]
1170 [46.1] OVERALL HEIGHT
CIRCUIT BREAKER SEE NOTE 3
REMOVE COVER FOR ACCESS TO LUBE OIL MAINTAINER SUPPLY TANK REFERENCE OWNERS MANUAL
REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS.
LEFT SIDE ROOF TOP
BATTERY LUBE OIL MAINTAINER SUPPLY TANK FILL CAP
SEE NOTE 11
EITHER SIDE
MUFFLER FAN BELT
LEFT SIDE SEE NOTE 11
SPARK PLUGS
LEFT SIDE
LEFT SIDE
RADIATOR FILL CAP AIR CLEANER ELEMENT
LEFT SIDE ROOF TOP
RADIATOR DRAIN HOSE COOLANT RECOVERY BOTTLE
LEFT SIDE RIGHT SIDE
OIL FILTER
OIL DIP STICK OIL DRAIN HOSE
RIGHT SIDE
OIL FILL CAP
FUEL LINE CONNECTION 3/4" NPT FEMALE COUPLING
1000 [39.4]
683.3 [26.9] CENTER OF GRAVITY
LEFT SIDE VIEW
50 [2.0]
167 [6.6] BATTERY 12V GROUP 26 NEGATIVE GROUND P/N: 077483
REMOVE COVER FOR ACCESS TO RADIATOR FILL CAP
AIR INTAKE (BOTH SIDES)
2.4L EITHER SIDE
SERVICE ITEM
602 [1328]
626 [1381]
SHIPPING WEIGHT KG [LBS]
DIMENSIONS: MM [INCH]
CUSTOMER ACCESS ASSEMBLY, CONTROL PANEL ACCESS, BATTERY CHARGER LOCATED WITHIN SEE NOTE 4
REAR ENCLOSURE COVER PANEL SEE NOTE 4
RIGHT SIDE VIEW
1950 [76.8] OVERALL LENGTH
1857 [73.1]
758 [29.8] DOOR TYP
58 [2.3] TYP
VICE ACTION LATCH, ONE PER DOOR, ONE LIFT OFF DOOR PER SIDE OF GENERATOR
1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194MM (47") WIDE X 2256MM (88.8") LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: - SEE SPECIFICATION SHEET OR OWNERS MANUAL - ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS THE STUB-UP AREAS AS FOLLOWS: - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. - LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. 11. EXHAUST MUFFLER AND FAN BELT ENCLOSED WITHIN GENERATOR ENCLOSURE, REMOVE FRONT PANEL TO ACCESS.
NOTES:
10 of 11
357 [14.0]
RADIATOR/EXHAUST DISCHARGE AIR (BOTH SIDES)
Protector ® Series
60 kW installation layout
Drawing #0L2090-B (1 of 2)
50 [2.0] TYP
13.5 X 29.5 MOUNTING SLOTS 4X
LEFT SIDE VIEW
1950 [76.8]
1750 [68.9] TYP MOUNTING SLOT CENTERS
TOP VIEW
1733 [68.2]
12 [.5]
217 [8.5]
162 [6.4] *STUB-UP AREA
25 [1.0] TYP
51 [2.0]
DIMENSIONS: MM [INCH]
9 [.4]
162 [6.4] *STUB-UP AREA
786 [30.9]
REAR VIEW
838 [33.0] TYP MOUNTING SLOT CENTERS 888 [35.0]
850 [33.5]
installation layout Drawing #0L2090-B (2 of 2)
©2017 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0L0037SBY-J 1/13/17
Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com
Protector ® Series
116 [4.6]
REMOVABLE STUB-UP COVER
*NOTE - STUB-UP AREA FOR HIGH AND LOW VOLTAGE CONNECTIONS. CIRCUIT BREAKER, NEUTRAL AND CUSTOMER CONNECTION.
60 kW
11 of 11