Protector® Series

   EMBED


Share

Transcript

PROTECTOR® SERIES Standby Generators Liquid-Cooled Gaseous Engine Protector ® Series Protector® Series 1 of 11 Standby Power Rating INCLUDES: • Two Line LCD Multilingual Digital Evolution™ Controller (English/Spanish/French/Portuguese) with external viewing window for easy indication of generator status and breaker position. Model RG025 (Aluminum - Bisque) - 25 kW 60 Hz Model RG030 (Aluminum - Bisque) - 30 kW 60 Hz Model RG036 (Aluminum - Bisque) - 36 kW 60 Hz Model RG045 (Aluminum - Bisque) - 45 kW 60 Hz Model RG060 (Aluminum - Bisque) - 60 kW 60 Hz • Capability to be installed with 18" (457mm) of a building* • True Power™ Electrical Technology • Isochronous Electronic Governor • Sound Attenuated Enclosure • Closed Coolant Recovery System • Smart Battery Charger • UV/Ozone Resistant Hoses • ±1% Voltage Regulation • Natural Gas or LP Operation • 5 Year Limited Warranty • UL 2200 Listed *Built in the USA using domestic and foreign parts Note: 25-45 kW units are field convertible between natural gas or liquid propane. 60 kW units are built per fuel requirement and are not convertible. *Only if located away from doors, windows, and fresh air intakes, and unless otherwise directed by local codes. Applicable for 25kW and 30kW units only. Meets EPA Emission Regulations 25, 30 & 45 kW CA/MA emissions compliant 36 & 60 kW not for sale in CA / MA FEATURES ¡  INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC’S success in “IMPROVING POWER BY DESIGN.” But it doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. ¡ TEST CRITERIA: a PROTOTYPE TESTED a SYSTEM TORSIONAL TESTED a NEMA MG1-22 EVALUATION a MOTOR STARTING ABILITY ¡  SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. Digital voltage regulation at ±1%. ¡  SINGLE SOURCE SERVICE RESPONSE from Generac’s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. ¡  G ENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. ISO 9 0 0 1: 2008 Protector ® Series 2 of 11 25 • 30 • 36 • 45 • 60 kW application & engineering data GENERATOR SPECIFICATIONS ENGINE SPECIFICATIONS: 25 & 30 kW Type Synchronous Make Rotor Insulation Class H Model Stator Insulation Class H Cylinders Telephone Interference Factor (TIF) <50 Generac In-line 4 Displacement (Liters) 1.5 Alternator Output Leads 1-Phase 4 wire Bore (in/mm) 3.05/77.4 Alternator Output Leads 3-Phase 6 wire Stroke (in/mm) 3.13/79.5 Bearings Sealed Ball Compression Ratio Coupling Flexible Disc Intake Air System Excitation System Direct VOLTAGE REGULATION Lifter Type Hydraulic ENGINE SPECIFICATIONS: 36, 45 & 60 kW Type Electronic Sensing Single Phase Regulation ± 1% Make Model Cylinders Displacement (Liters) GOVERNOR SPECIFICATIONS Type Electronic Frequency Regulation Isochronous Steady State Regulation ± 0.25% 12 Volt 15 Amp - 25 & 30 kW 12 Volt 30 Amp - 36, 45 & 60 kW Static Battery Charger 2 Amp Recommended Battery (battery not included) Group 26, 525CCA System Voltage 12 Volts GENERATOR FEATURES Revolving field heavy duty generator Directly connected to the engine Operating temperature rise 120 °C above a 40 °C ambient Class H insulation is NEMA rated All models fully prototyped tested ENCLOSURE FEATURES In-line 4 2.4 3.41/86.5 Stroke (in/mm) 3.94/100 Compression Ratio Lifter Type 9.5:1 Naturally Aspirated (36 & 45 kW) or Turbocharged/Aftercooled (60 kW) Hydraulic ENGINE LUBRICATION SYSTEM Oil Pump Type Gear Oil Filter Type Full flow spin-on cartridge Crankcase Capacity (qt/l) 4/3.8 - 25, 30, 36 & 45 kW 5.25/4.96 - 60 kW ENGINE COOLING SYSTEM Type Water Pump Fan Speed (rpm) Aluminum weather protective enclosure Ensures protection against mother nature. Electrostatically applied textured epoxy paint for added durability. Fan Diameter (in/mm) Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. Fan Mode Small, compact, attractive Makes for an easy, eye appealing installation. SAE Sound attenuated enclosure ensures quiet operation. Closed Belt driven 2484 - 25 & 30 kW 1865 - 36 & 45 kW 2100 - 60 kW 17.7/449.6 (25 & 30 kW) or 22/558.8 (36, 45 & 60 kW) Pusher (25 & 30 kW) or Puller (36, 45 & 60 kW) FUEL SYSTEM Fuel Type Carburetor Natural gas, propane vapor Down Draft Secondary Fuel Regulator Standard Fuel Shut Off Solenoid Standard Operating Fuel Pressure (All ratings in accordance with BS5514, ISO3046, ISO8528, SAE J1349 and DIN6271) Generac Bore (in/mm) Intake Air System ELECTRICAL SYSTEM Battery Charge Alternator 11:1 Naturally Aspirated 5-14" water column/9-26 mm HG LP Fuel Pressure 11 - 14" Water Column NG Fuel Pressure 5 - 14" Water Column operating data GENERATOR OUTPUT VOLTAGE/kW - 60 Hz RG025 RG030 RG036 RG045 RG060 kW LPG Amp LPG kW Nat. Gas Amp Nat. Gas CB Size (Both) 120/240 V, 1Ø, 1.0 pf 25 104 25 104 125 120/208 V, 3Ø, 0.8 pf 25 87 25 87 100 120/240 V, 3Ø, 0.8 pf 25 75 25 75 90 120/240 V, 1Ø, 1.0 pf 30 125 30 125 150 120/208 V, 3Ø, 0.8 pf 30 104 30 104 125 120/240 V, 3Ø, 0.8 pf 30 90 30 90 100 120/240 V, 1Ø, 1.0 pf 36 150 36 150 175 120/208 V, 3Ø, 0.8 pf 36 125 36 125 150 120/240 V, 3Ø, 0.8 pf 36 108 36 108 125 277/480 V, 3Ø, 0.8 pf 36 54 36 54 60 120/240 V, 1Ø, 1.0 pf 45 188 45 188 200 120/208 V, 3Ø, 0.8 pf 45 156 45 156 175 120/240 V, 3Ø, 0.8 pf 45 135 45 135 150 277/480 V, 3Ø, 0.8 pf 45 68 45 68 80 120/240 V, 1Ø, 1.0 pf 60 250 60 250 300 120/208 V, 3Ø, 0.8 pf 60 208 60 208 250 120/240 V, 3Ø, 0.8 pf 60 180 60 180 200 277/480 V, 3Ø, 0.8 pf 60 90 60 90 100 SURGE CAPACITY IN AMPS RG025 RG030 RG036 RG045 RG060 3 of 11 ENGINE FUEL CONSUMPTION Voltage Dip @ < .4 pf 15% 30% 120/240 V, 1Ø 65 170 120/208 V, 3Ø 80 130 120/240 V, 3Ø 69 112 120/240 V, 1Ø 75 120/208 V, 3Ø 120/240 V, 3Ø Natural Gas Propane (ft³/hr) (m³ /hr) (gal/hr) (l/hr) (ft³/hr) 22 0.6 0.2 0.8 8.0 25% of rated load 93 2.6 0.7 2.8 27 50% of rated load 140 4 1.2 4.8 45 180 75% of rated load 180 5.1 1.7 6.4 60 96 155 100% of rated load 221 6.3 2.1 7.9 75 83 134 Exercise cycle 22 0.6 0.2 0.8 8.0 120/240 V, 1Ø 105 240 25% of rated load 93 2.6 0.7 2.8 27 120/208 V, 3Ø 44 130 50% of rated load 140 4 1.2 4.8 45 120/240 V, 3Ø 38 115 75% of rated load 180 5.1 1.7 6.5 60 277/480 V, 3Ø 20 60 100% of rated load 221 6.3 2.1 7.9 75 120/240 V, 1Ø 105 240 Exercise cycle 63 1.8 0.6 2.5 23 120/208 V, 3Ø 44 130 25% of rated load 194 5.5 2.2 8.3 78 120/240 V, 3Ø 38 115 50% of rated load 332 9.4 3.5 13.6 179 277/480 V, 3Ø 20 60 75% of rated load 479 13 5 18 216 120/240 V, 1Ø 140 320 100% of rated load 626 17 6.4 24 231 120/208 V, 3Ø 70 210 Exercise cycle 83 2.2 0.8 3.1 30 120/240 V, 3Ø 61 182 25% of rated load 315 8.9 3.1 11.7 111 277/480 V, 3Ø 30 91 50% of rated load 501 14 5 18.8 177.7 75% of rated load 692 19.6 7 26 249 100% of rated load 836 23.7 8.6 32.7 309.5 Exercise cycle RG025 RG030 RG036 RG045 Note: Fuel pipe must be sized for full load. Exercise cycle 105 2.9 1.1 4.2 40 For Btu content, multiply ft³/hr x 2520 (LP) or ft³/hr x 1000 (NG) 25% of rated load 390.6 11 4 15 143.5 50% of rated load 610.8 17 6.5 24.5 231.6 For megajoule content, multiply m³/hr x 93.15 (LP) or m³/hr x 37.26 (NG) Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCAQMD permitting purposes. RG060 Protector ® Series 25 • 30 • 36 • 45 • 60 kW 75% of rated load 824 23 8.8 33 314 100% of rated load 1051 29.8 11 42 400 STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice. Protector ® Series 25 • 30 • 36 • 45 • 60 kW ENGINE COOLING Air flow (inlet air including alternator and combustion air in cfm/cmm) 4 of 11 operating data System coolant capacity (gal/liters) Heat rejection to coolant (BTU per hr/MJ per hr) 25 kW 30 kW 36 kW 45 kW 60 kW 2490/70.5 2490/70.5 2725/77.2 2725/77.2 3280/92.9 2/7.6 2/7.6 2.5/9.5 2.5/9.5 2.5/9.5 112,000/118.2 135,000/142.4 193,000/203.6 193,000/203.6 270,000/284.9 Maximum operation air temperature on radiator (°C/°F) 60/140 Maximum ambient temperature (°C/°F) 50/122 COMBUSTION REQUIREMENTS Flow at rated power (cfm/cmm) 62/1.8 72/2 144/4.1 144/4.1 180/5.1 Sound output in dB(A) at 23 ft (7 m) with generator in exercise mode* 59 59 61 61 65 Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load* 72 73 70 73 72 SOUND EMISSIONS *Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. EXHAUST Exhaust flow at rated output (cfm/cmm) Exhaust temperature at muffler outlet (°C/°F) 203/5.7 237/6.7 300/8.5 420/11.9 494/14 593/1100 610/1130 579/1075 593/1100 566/1050 ENGINE PARAMETERS Rated Synchronous rpm 3600 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration............................................................................................................3% for every 10 °C above 25 °C or 1.65% for every 10 °F above 77 °F Altitude Deration (25, 30, 36 & 45 kW)................................................................................1% for every 100 m above 183 m or 3% for every 1000 ft above 600 ft Altitude Deration (60 kW) ................................................................................................. 1% for every 100 m above 915 m or 3% for every 1000 ft above 3000 ft CONTROLLER FEATURES 2-Line Plain Text LCD Display.........................................................................................................................................Simple user interface for ease of operation. Mode Switch: Auto ...............................................................................................................................................Automatic Start on Utility failure. 7 day exerciser Off............................................................................................................................Stops unit. Power is removed. Control and charger still operate. Manual.......................................................................................... Start with starter control, unit stays on. If utility fails, transfer to load takes place. Programmable start delay between 10-30 seconds............................................................................................................................................................. Standard Engine Start Sequence...................................................................................................................... Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration) Engine Warm-up...................................................................................................................................................................................................................... 5 sec Engine Cool-Down...................................................................................................................................................................................................................1 min Starter Lock-out.................................................................................................................................Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger......................................................................................................................................................................................................... Standard Automatic Voltage Regulation with Over and Under Voltage Protection................................................................................................................................. Standard Automatic Low Oil Pressure Shutdown................................................................................................................................................................................ Standard Overspeed Shutdown............................................................................................................................................................................................... Standard, 72 Hz High Temperature Shutdown................................................................................................................................................................................................ Standard Overcrank Protection........................................................................................................................................................................................................... Standard Safety Fused....................................................................................................................................................................................................................... Standard Failure to Transfer Protection............................................................................................................................................................................................... Standard Low Battery Protection......................................................................................................................................................................................................... Standard 50 Event Run Log................................................................................................................................................................................................................ Standard Future Set Capable Exerciser............................................................................................................................................................................................... Standard Incorrect Wiring Protection.................................................................................................................................................................................................. Standard Internal Fault Protection...................................................................................................................................................................................................... Standard Common External Fault Capability....................................................................................................................................................................................... Standard Governor Failure Protection................................................................................................................................................................................................. Standard Model # G006463-4 available accessories Product Description Mobile Link™ Generac's Mobile Link allows you to check the status of your generator from anywhere that you have access to an Internet connection from a PC or with any smart device. You will even be notified when a change in the generator’s status occurs via e-mail or text message. Note: Harness Adapter Kit required. Available in the U.S. only. Harness Adapter Kit The Harness Adapter Kit is required to make liquid-cooled units compatible with Mobile Link™. Cold Weather Kit If the temperature regularly falls below 32 °F (0 °C), install a cold weather kit to maintain optimal battery temperature. Kit consists of battery warmer with thermostat built into the wrap. G005616-0 - 36, 45 & 60 kW Extreme Cold Weather Kit Recommended where the temperature regularly falls below 32 °F (0 °C) for extended periods of time. For liquid cooled units only. G005651-0 Base Plug Kit Add base plugs to the base of the generator to keep out debris. G005703-0 - Bisque Paint Kit If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. Scheduled Maintenance Kit The Liquid-Cooled Scheduled Maintenance Kits offer all the hardware necessary to perform complete maintenance on Generac liquid-cooled generators. G006664-0 Local Wireless Monitor Completely wireless and battery powered, Generac's wireless remote monitor provides you with instant status information without ever going outside. G006665-0 Wireless Remote Extension Harness Recommended for use with the Wireless Remote on units up to 60 kW, required for use on units 70 kW or greater. G006873-0 Smart Management Module (50 Amps) Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its power management capabilities. It provides additional power management flexibility not found in any other power management system. G006510-0 E-Stop E-stop allows for immediate fuel shutoff and generator shutdown in the event of an emergency. G006478-0 G006175-0 - 25 & 30 kW G005630-1 - 36, 45 & 60 kW G006174-0 - 25 & 30 kW G006176-0 - 25 & 30 kW G006172-0 - 36 & 45 kW G006171-0 - 60 kW Protector ® Series 25 • 30 • 36 • 45 • 60 kW 5 of 11 LEFT SIDE VIEW TOP VIEW RADIATOR/EXHAUST DISCHARGE AIR (BOTH SIDES) EXHAUST MUFFLER ENCLOSED WITHIN GENERATOR ENCLOSURE RADIATOR/EXHAUST DISCHARGE AIR REMOVE COVER FOR ACCESS TO RADIATOR FILL CAP BATTERY 12V GROUP 26 NEGATIVE GROUND P/N: 077483 RIGHT DOOR RIGHT DOOR OIL FILTER OIL DRAIN HOSE RADIATOR DRAIN HOSE RIGHT DOOR RIGHT DOOR OIL FILL CAP OIL DIP STICK RIGHT DOOR FAN BELT BATTERY ENCLOSURE MATERIAL ST ST AL AL 1.5L/25KW 1.5L/30KW 1.5L/25KW 1.5L/30KW 366 [807] 352 [777] 406 [895] 392 [865] WEIGHT GENSET ONLY KG [LBS] WEIGHT DATA LIFTING PROVISION (4 PLACES) SEE NOTES 5, 8 AND CENTER OF GRAVITY DIMENSIONS. 978 (38.5) OVERALL HEIGHT 30 [66] 30 [66] 30 [66] 30 [66] WEIGHT SHIPPING SKID KG [LBS] 396 [873] 382 [843] 436 [961] 422 [931] 48 (1.8) Drawing #0K8420-B (1 of 2) 47.6 (2.9) 783 (30.7) VISE ACTION LATCH, ONE PER DOOR, ONE LIFT-OFF DOOR PER SIDE OF GENERATOR. RIGHT SIDE VIEW 1490 (57.6) 630 (24.8) DOOR TYP FUEL LINE CONNECTION 3/4" NPT FEMALE COUPLING 44 (1.7) 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1092 (43") WIDE X 1887 (74.3") LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: - SEE SPECIFICATION SHEET OR OWNERS MANUAL - ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS THE STUB-UP AREAS AS FOLLOWS: - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. - LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7. EXHAUST SYSTEM MAXIMUM BACK PRESSURE: 24 INCHES H2O. 8. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 9. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 10. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 11. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. 12. EXHAUST MUFFLER ENCLOSED WITHIN GENERATOR ENCLOSURE, REMOVE ENCLOSURE TO ACCESS EXHAUST MUFFLER. NOTES: CIRCUIT BREAKER NEUTRAL AND CUSTOMER CONNECTION OPENING DIMENSIONS: MM [INCH] CUSTOMER ACCESS ASSEMBLY, CONTROL PANEL ACCESS, BATTERY CHARGER LOCATED WITHIN SEE NOTE 4 CIRCUIT BREAKER SEE NOTE 3 REAR ENCLOSURE COVER PANEL SEE NOTE 4 SHIPPING WEIGHT KG [LBS] REAR VIEW EITHER DOOR MUFFLER REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. RIGHT DOOR SEE NOTE 12 SPARK PLUGS AIR CLEANER ELEMENT RIGHT DOOR ENGINE/KW 665.5 [26.2"] CENTER OF GRAVITY (SEE NOTE 5) 1.5L EITHER DOOR SERVICE ITEM 6 of 11 AIR INTAKE (BOTH SIDES) Protector ® Series 25 & 30 kW installation layout 45 (1.8) TYP 13.5 X 29.5 MOUNTING SLOTS 4X LEFT SIDE VIEW 1580 (62.2) 1345 (60.8) TOP VIEW 1380 (54.3) TYP MOUNTING SLOT CENTERS 50 (1.9) 226 (8.9) 100 (3.9) STUB-UP AREA 51 (2.0) DIMENSIONS: MM [INCH] 9 (.4) 104.5 (4.1) STUB-UP AREA 27 (1.0) TYP 674 (26.5) REAR VIEW 776 (30.6) 723 (28.5) TYP MOUNTING SLOT CENTERS 735 (28.9) installation layout Drawing #0K8420-B (2 of 2) Protector ® Series REMOVABLE STUB-UP COVER 96 (3.8) *NOTE - STUB-UP AREA FOR HIGH AND LOW VOLTAGE CONNECTIONS. CIRCUIT BREAKER, NEUTRAL AND CUSTOMER CONNECTION OPENING. 25 & 30 kW 7 of 11 187 [7.4] RADIATOR/EXHAUST DISCHARGE AIR EXHAUST MUFFLER ENCLOSED WITHIN GENERATOR ENCLOSURE 443 [17.5] AL ST AL 2.4L 45KW 2.4L 60KW 2.4L 60KW AL ST ST 2.4L 45KW 2.4L 36KW 2.4L 36KW ENCLOSURE MATERIAL ENGINE/KW WEIGHT DATA 558 [1230] 582 [1283] 572 [1260] 596 [1313] 545 [1202] 569 [1255] WEIGHT GENSET ONLY KG [LBS] 1170 [46.1] OVERALL HEIGHT 44 [98] 44 [98] 44 [98] 44 [98] 44 [98] 44 [98] WEIGHT SHIPPING SKID KG [LBS] 888 [35.0] OVERALL WIDTH REAR VIEW REMOVE COVER FOR ACCESS TO LUBE OIL MAINTAINER SUPPLY TANK REFERENCE OWNERS MANUAL REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. LEFT SIDE ROOF TOP BATTERY LUBE OIL MAINTAINER SUPPLY TANK FILL CAP CIRCUIT BREAKER SEE NOTE 3 749.3 [29.5] CENTER OF GRAVITY (SEE NOTE 5) DRIVE BELT SEE NOTE 11 EITHER SIDE MUFFLER FAN BELT LEFT SIDE SEE NOTE 11 SPARK PLUGS LEFT SIDE LEFT SIDE AIR CLEANER ELEMENT LEFT SIDE ROOF TOP RADIATOR FILL CAP RADIATOR DRAIN HOSE RIGHT SIDE RIGHT SIDE OIL FILTER OIL DRAIN HOSE OIL DIP STICK COOLANT RECOVERY BOTTLE 50 1000 [39.4] [2.0] FUEL LINE CONNECTION LEFT SIDE VIEW 3/4" NPT FEMALE COUPLING BATTERY 12V GROUP 26 NEGATIVE GROUND P/N: 077483 TOP VIEW REMOVE COVER FOR ACCESS TO RADIATOR FILL CAP AIR INTAKE (BOTH SIDES) RIGHT SIDE OIL FILL CAP Drawing #0K8636-B (1 of 2) 58 [2.3] TYP 602 [1328] 626 [1381] 616 [1358] 640 [1411] 590 [1300] 613 [1353] SHIPPING WEIGHT KG [LBS] DIMENSIONS: MM [INCH] CUSTOMER ACCESS ASSEMBLY, CONTROL PANEL ACCESS, BATTERY CHARGER 46.5 LOCATED WITHIN [1.83] SEE NOTE 4 REAR ENCLOSURE COVER PANEL SEE NOTE 4 1950 [76.8] OVERALL LENGTH RIGHT SIDE VIEW 1857 [73.1] TYP 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194MM (47") WIDE X 2256MM (88.8") LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: - SEE SPECIFICATION SHEET OR OWNERS MANUAL - ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS THE STUB-UP AREAS AS FOLLOWS: - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. - LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. 11. EXHAUST MUFFLER AND FAN BELT ENCLOSED WITHIN GENERATOR ENCLOSURE, VICE ACTION LATCH, REMOVE FRONT PANEL TO ACCESS. ONE PER DOOR, ONE LIFT OFF DOOR PER SIDE 758 [29.8] OF GENERATOR DOOR TYP NOTES: 8 of 11 RADIATOR/EXHAUST DISCHARGE AIR (BOTH SIDES) 2.4L EITHER SIDE SERVICE ITEM Protector ® Series 36 & 45 kW installation layout 50 [2.0] TYP 13.5 X 29.5 MOUNTING SLOTS 4X LEFT SIDE VIEW 1950 [76.8] 1750 [68.9] TYP MOUNTING SLOT CENTERS TOP VIEW 1733 [68.2] 12 [.5] 217 [8.5] DIMENSIONS: MM [INCH] 25 [1.0] TYP 162 [6.4] *STUB-UP AREA 9 [.4] 162 [6.4] *STUB-UP AREA 850 [33.5] REAR VIEW 888 [35.0] 838 [33.0] TYP MOUNTING SLOT CENTERS 51 [2.0] 786 [30.9] installation layout Drawing #0K8636-B (2 of 2) Protector ® Series 116 [4.6] REMOVABLE STUB-UP COVER *NOTE - STUB-UP AREA FOR HIGH AND LOW VOLTAGE CONNECTIONS. CIRCUIT BREAKER, NEUTRAL AND CUSTOMER CONNECTION OPENINGS. 36 & 45 kW 9 of 11 RADIATOR/EXHAUST DISCHARGE AIR EXHAUST MUFFLER ENCLOSED WITHIN GENERATOR ENCLOSURE TOP VIEW DRIVE BELT ENCLOSURE MATERIAL ST AL ENGINE/KW 2.4L 60KW 2.4L 60KW WEIGHT DATA 582 [1283] 558 [1230] 44 [98] 44 [98] WEIGHT SHIPPING SKID KG [LBS] REAR VIEW 888 [35.0] OVERALL WIDTH WEIGHT GENSET ONLY KG [LBS] 1170 [46.1] OVERALL HEIGHT CIRCUIT BREAKER SEE NOTE 3 REMOVE COVER FOR ACCESS TO LUBE OIL MAINTAINER SUPPLY TANK REFERENCE OWNERS MANUAL REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. LEFT SIDE ROOF TOP BATTERY LUBE OIL MAINTAINER SUPPLY TANK FILL CAP SEE NOTE 11 EITHER SIDE MUFFLER FAN BELT LEFT SIDE SEE NOTE 11 SPARK PLUGS LEFT SIDE LEFT SIDE RADIATOR FILL CAP AIR CLEANER ELEMENT LEFT SIDE ROOF TOP RADIATOR DRAIN HOSE COOLANT RECOVERY BOTTLE LEFT SIDE RIGHT SIDE OIL FILTER OIL DIP STICK OIL DRAIN HOSE RIGHT SIDE OIL FILL CAP FUEL LINE CONNECTION 3/4" NPT FEMALE COUPLING 1000 [39.4] 683.3 [26.9] CENTER OF GRAVITY LEFT SIDE VIEW 50 [2.0] 167 [6.6] BATTERY 12V GROUP 26 NEGATIVE GROUND P/N: 077483 REMOVE COVER FOR ACCESS TO RADIATOR FILL CAP AIR INTAKE (BOTH SIDES) 2.4L EITHER SIDE SERVICE ITEM 602 [1328] 626 [1381] SHIPPING WEIGHT KG [LBS] DIMENSIONS: MM [INCH] CUSTOMER ACCESS ASSEMBLY, CONTROL PANEL ACCESS, BATTERY CHARGER LOCATED WITHIN SEE NOTE 4 REAR ENCLOSURE COVER PANEL SEE NOTE 4 RIGHT SIDE VIEW 1950 [76.8] OVERALL LENGTH 1857 [73.1] 758 [29.8] DOOR TYP 58 [2.3] TYP VICE ACTION LATCH, ONE PER DOOR, ONE LIFT OFF DOOR PER SIDE OF GENERATOR 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194MM (47") WIDE X 2256MM (88.8") LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE, AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: - SEE SPECIFICATION SHEET OR OWNERS MANUAL - ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS THE STUB-UP AREAS AS FOLLOWS: - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. - LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. 6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. 11. EXHAUST MUFFLER AND FAN BELT ENCLOSED WITHIN GENERATOR ENCLOSURE, REMOVE FRONT PANEL TO ACCESS. NOTES: 10 of 11 357 [14.0] RADIATOR/EXHAUST DISCHARGE AIR (BOTH SIDES) Protector ® Series 60 kW installation layout Drawing #0L2090-B (1 of 2) 50 [2.0] TYP 13.5 X 29.5 MOUNTING SLOTS 4X LEFT SIDE VIEW 1950 [76.8] 1750 [68.9] TYP MOUNTING SLOT CENTERS TOP VIEW 1733 [68.2] 12 [.5] 217 [8.5] 162 [6.4] *STUB-UP AREA 25 [1.0] TYP 51 [2.0] DIMENSIONS: MM [INCH] 9 [.4] 162 [6.4] *STUB-UP AREA 786 [30.9] REAR VIEW 838 [33.0] TYP MOUNTING SLOT CENTERS 888 [35.0] 850 [33.5] installation layout Drawing #0L2090-B (2 of 2) ©2017 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0L0037SBY-J 1/13/17 Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com Protector ® Series 116 [4.6] REMOVABLE STUB-UP COVER *NOTE - STUB-UP AREA FOR HIGH AND LOW VOLTAGE CONNECTIONS. CIRCUIT BREAKER, NEUTRAL AND CUSTOMER CONNECTION. 60 kW 11 of 11