Prices as of April 15, 2015. Check Web site for most current prices. Discrete Input Terminals PX-144 $34.00 General Specifications Four-point, 24VDC Discrete Input Terminal The PX-144 (type 1) DC Input Terminal provides four electrically isolated 24VDC sinking inputs with LED status. For use with 3-wire and 2-wire sensors. Operating Temp Storage Temp Relative Humidity Environment Air Mounting/ Orientation Restrictions Vibration Shock Noise Immunity LED Input 1 LED Input 2 LED Input 3 LED Input 4 Input 1 1 5 +24VDC 2 6 3 4 7 Input 3 1 5 2 6 3 7 4 8 Input 2 +24VDC 3Wire 0V Input 4 8 PX-144 32 to 131 °F (0 to 55 °C) 13 to 185 °F (-25 to 85 °C) 5% to 95%, non-condensing No corrosive gases permitted 35mm DIN rail/None conforms to EN 60068-2-6 conforms to EN 60068-2-27/ EN 60068-2-29 conforms to EN 61000-6-2/ EN61000-6-4 Protection Class Weight Dimensions (WxHxD) Adjacent Mounting on Bus Terminals with Power Contact Adjacent Mounting on Bus Terminals without Power Contact Passes Terminal Bus Power IP20 Passes PE Bus No 55g 12mm x 100mm x 68.8 mm (0.47 in x 3.94 in x 2.71 in) Yes, DC only No Company Information Terminal Specifications Inputs Per Terminal Input Type Input Data Bytes Used Input Power Source Current Consumption (from Terminal Power Bus) Operating Voltage Rating Peak Voltage Rating ON Voltage Level OFF Voltage Level Minimum ON Current Maximum OFF Current Current Consumption (from I/O Bus) Electrical Isolation Heat Dissipation OFF to ON Response ON to OFF Response Status Indicators 4 Sinking 1/2 byte (4 bits) 24VDC provided via terminal power bus 5mA typical 24VDC (-15%/+20%) 30VDC 15 to 30 VDC -3 to +5 VDC 50mA 100mA 5mA typical 500Vms (I/O bus/field potential) 1W max 3ms 3ms 4, indicates input is ON Eight-point, 24VDC Discrete Input Terminal The PX-148 (type 1) DC Input Terminal provides eight electrically isolated 24VDC sinking inputs with LED status. Operating Temp Storage Temp Relative Humidity Environment Air Mounting/ Orientation Restrictions Vibration Shock Noise Immunity Signal LED Signal LED 2 4 6 8 1 3 5 7 Input 1 Input 3 Input 5 Input 7 PX-148 1 5 2 6 3 7 4 8 Input 2 Input 4 Input 6 Input 8 24 VDC Power Supply + – Connect power supply common (–) to same common as terminal power bus Protection Class Weight Dimensions (WxHxD) 32 to 131 °F (0 to 55 °C) 13 to 185 °F (-25 to 85 °C) 5% to 95%, non-condensing No corrosive gases permitted 35mm DIN rail/None conforms to EN 60068-2-6 conforms to EN 60068-2-27/ EN 60068-2-29 conforms to EN 61000-6-2/ EN61000-6-4 IP20 55g 12mm x 100mm x 68.8 mm (0.47 in x 3.94 in x 2.71 in) Adjacent Mounting on Bus Terminals Yes, DC only with Power Contact Adjacent Mounting on Bus Terminals No without Power Contact Passes Terminal Yes Bus Power Do-More T1H PLC DirectLOGIC PLCs Overview DirectLOGIC DL05/06 DirectLOGIC DL105 DirectLOGIC DL205 DirectLOGIC DL305 Universal Field I/O Terminal Specifications Inputs Per Terminal Input Type Input Data Bytes Used Input Power Source Current Consumption (from Terminal Power Bus) Operating Voltage Rating Peak Voltage Rating ON Voltage Level OFF Voltage Level Minimum ON Current Maximum OFF Current Current Consumption (from I/O Bus) Electrical Isolation Heat Dissipation OFF to ON Response ON to OFF Response Status Indicators 8 Sinking 1 byte Requires external 24VDC power source 2mA + load, typical 24VDC (-15%/+20%) 30VDC 15 to 30 VDC -3 to +5 VDC 2mA 1.5 mA 5mA typical 500Vms (I/O bus/field potential) 1W max 3ms 3ms 8, indicates input is ON No Passes PE Bus Agency Approvals* UL/cUL File No. E157382, CE *To obtain the most current agency approval information, see the Agency Approval Checklist section on the specific part number’s web page. www.automationdirect.com/fieldIO Do-More H2 PLC Productivity 3000 see the Agency Approval Checklist section on the specific part number’s web page. General Specifications Do-More PLCs Overview Productivity Controller Overview Yes Agency Approvals* UL/cUL File No. E157382, CE $55.00 CLICK PLC DirectLOGIC DL405 *To obtain the most current agency approval information, PX-148 Control Systems Overview Book 1 (14.3) Universal Field I/O eFD-31 Software C-More HMI C-More Micro HMI ViewMarq Industrial Marquees Other HMI Communications Appendix Book 1 Terms and Conditions Prices as of April 15, 2015. Check Web site for most current prices. Discrete Input Terminals PX-149 $95.00 General Specifications Operating Temp Storage Temp Relative Humidity Environment Air Mounting/ Orientation Restrictions Vibration Sixteen-point, 24VDC Discrete Input Terminal The PX-149 (type 1) DC Input Terminal provides sixteen electrically isolated 24VDC sinking inputs with LED status. Shock Noise Immunity PX-149 1 Input LED 1 3 10 3 4 11 12 4 5 5 6 13 6 7 14 15 16 7 8 1 9 10 11 2 13 14 15 16 2 9 2 Input LED Input 1 Input 2 9 2 10 3 11 4 12 5 13 6 14 7 15 8 16 Input 3 Input 4 Input 5 Input 6 Input 7 Input 8 8 1 9 2 10 3 11 4 5 12 13 6 14 7 15 8 16 24 VDC Power Supply + Input 9 – Input 10 Input 11 Connect power supply common (–) to same common as terminal power bus Input 12 Input 13 Input 14 Input 15 Input 16 Protection Class Weight Dimensions (WxHxD) 32 to 131 °F (0 to 55 °C) 13 to 185 °F (-25 to 85 °C) 5% to 95%, non-condensing Input Power Source Current Consumption 35mm DIN rail/None (from Terminal Power Bus) Operating Voltage Rating conforms to EN 60068-2-6 Peak Voltage Rating conforms to EN 60068-2-27/ ON Voltage Level EN 60068-2-29 OFF Voltage Level conforms to EN 61000-6-2/ EN61000-6-4 Minimum ON Current Maximum OFF Current IP20 Current Consumption 60g (from I/O Bus) No corrosive gases permitted 12mm x 100mm x 68.8 mm (0.47 in x 3.94 in x 2.71 in) Adjacent Mounting on Bus Terminals Yes, DC only with Power Contact Adjacent Mounting on Bus Terminals without Power Contact Passes Terminal Bus Power Passes PE Bus Agency Approvals* Terminal Specifications Inputs Per Terminal Input Type Input Data Bytes Used Electrical Isolation Heat Dissipation OFF to ON Response ON to OFF Response Status Indicators 16 Sinking 2 bytes Requires external 24VDC power source NA 24VDC (-15%/+20%) 30VDC 11 to 30 VDC -3 to +5 VDC 2mA 40mA 20mA typical 500Vms (I/O bus/field potential) 1W max 3ms 3ms 16, indicates input is ON No Yes No UL/cUL File No. E157382, CE *To obtain the most current agency approval information, see the Agency Approval Checklist section on the specific part number’s web page. PX-172-1 $36.00 General Specifications Two-point, 120-230 VAC Discrete Input Terminal The PX-172-1 (type 2) DC Input Terminal provides two electrically isolated 120-230 VAC inputs with LED status. For use with 4-wire, 3-wire and 2-wire devices. Operating Temp Storage Temp Relative Humidity Environment Air Mounting/ Orientation Restrictions Vibration Shock Noise Immunity LED Input 2 LED Input 1 Input 1 120230 VAC 3Wire 0V PE 1 2 5 6 3 7 4 8 Input 2 120230 VAC 0V 4Wire PE Note: Terminal PX-908 is recommended to isolate terminal power or use PX-970 to supply and isolate power. PX-172-1 Protection Class Weight Dimensions (WxHxD) Adjacent Mounting on Bus Terminals with Power Contact Adjacent Mounting on Bus Terminals without Power Contact Passes Terminal Bus Power Passes PE Bus Agency Approvals* 32 to 131 °F (0 to 55 °C) 13 to 185 °F (-25 to 85 °C) 5% to 95%, non-condensing Terminal Specifications Inputs Per Terminal Input Type Input Data Bytes Used 2 NA 1/4 byte (2 bits) Input Power Source Requires external 120-230 VAC power source. PX-908 terminal recommended to provide power to the terminal power bus. No corrosive gases permitted 35mm DIN rail/None conforms to EN 60068-2-6 conforms to EN 60068-2-27/ EN 60068-2-29 conforms to EN 61000-6-2/ EN61000-6-4 IP20 60g 12mm x 100mm x 68.8 mm (0.47 in x 3.94 in x 2.71 in) Yes, AC only Current Consumption (from Terminal Power Bus) Operating Voltage Rating Peak Voltage Rating ON Voltage Level OFF Voltage Level Minimum ON Current Maximum OFF Current Current Consumption (from I/O Bus) Electrical Isolation No Yes Heat Dissipation OFF to ON Response ON to OFF Response Status Indicators 6mA typical 120 to 230 VAC 260VAC 79 to 260 VAC 0 to 40 VAC 250mA 500mA 3mA typical 500Vms (I/O bus/field potential) 1W max 10ms 10ms 2, indicates input is ON Yes UL/cUL File No. E157382, CE *To obtain the most current agency approval information, see the Agency Approval Checklist section on the specific part number’s web page. Book 1 (14.3) eFD-32 Universal Field I/O 1-800-633-0405 Prices as of April 15, 2015. Check Web site for most current prices. Discrete Input Terminals PX-172-2 $36.00 General Specifications Two-point, 120 VAC/VDC Discrete Input Terminal The PX-172-2 (type 2) DC Input Terminal provides two electrically isolated 120 VAC/VDC inputs with LED status. For use with 4-wire, 3-wire and 2-wire devices. Operating Temp Storage Temp Relative Humidity Environment Air Mounting/ Orientation Restrictions Vibration Shock Noise Immunity LED Input 2 LED Input 1 Input 1 120 VAC/ VDC 3Wire 0V PE 1 2 5 6 3 7 4 8 Input 2 120 VAC/ VDC 0V 4Wire PE Note: Terminal PX-908 is recommended to isolate terminal power or use PX-970 to supply and isolate power. PX-172 32 to 131 °F (0 to 55 °C) 13 to 185 °F (-25 to 85 °C) 5% to 95%, non-condensing Company Information Terminal Specifications Inputs Per Terminal Input Type Input Data Bytes Used 2 NA 1/4 byte (2 bits) Input Power Source Requires external 120 VAC/VDC power source. PX-908 terminal recommended to provide power to the terminal power bus. No corrosive gases permitted 35mm DIN rail/None conforms to EN 60068-2-6 conforms to EN 60068-2-27/ EN 60068-2-29 conforms to EN 61000-6-2/ EN61000-6-4 Protection Class Weight Dimensions (WxHxD) Adjacent Mounting on Bus Terminals with Power Contact Adjacent Mounting on Bus Terminals without Power Contact Passes Terminal Bus Power IP20 Passes PE Bus Yes 60g 12mm x 100mm x 68.8 mm (0.47 in x 3.94 in x 2.71 in) Yes, 120 VAC/VDC only No Yes Current Consumption (from Terminal Power Bus) Operating Voltage Rating Peak Voltage Rating ON Voltage Level OFF Voltage Level Minimum ON Current Maximum OFF Current Current Consumption (from I/O Bus) Electrical Isolation Heat Dissipation OFF to ON Response ON to OFF Response Status Indicators 6mA typical Control Systems Overview CLICK PLC Do-More PLCs Overview Do-More H2 PLC Do-More T1H PLC 120 VAC/VDC 140 VAC/VDC 80 to 140 VAC/VDC 0 to 40 VAC/VDC 250mA 500mA DirectLOGIC PLCs Overview 3mA typical DirectLOGIC DL205 500Vms (I/O bus/field potential) 1W max 10ms 10ms 2, indicates input is ON DirectLOGIC DL05/06 DirectLOGIC DL105 DirectLOGIC DL305 DirectLOGIC DL405 Productivity Controller Overview Productivity 3000 Agency Approvals* UL/cUL File No. E157382, CE *To obtain the most current agency approval information, Universal Field I/O see the Agency Approval Checklist section on the specific part number’s web page. Software C-More HMI C-More Micro HMI ViewMarq Industrial Marquees Other HMI Communications Appendix Book 1 Terms and Conditions Book 1 (14.3) www.automationdirect.com/fieldIO Universal Field I/O eFD-33 Prices as of April 15, 2015. Check Web site for most current prices. Discrete Output Terminals PX-244-1 $51.00 General Specifications Four-point, 0.5 A, 24VDC Discrete Output Terminal The PX-244-1 (type 1) DC Output Terminal provides four 24VDC 0.5 A short-circuit protected sourcing outputs with LED status. For use with 3-wire and 2-wire devices. Operating Temp Storage Temp Relative Humidity Environment Air Mounting/ Orientation Restrictions Vibration Shock Noise Immunity LED Output 1 LED Output 2 LED Output 3 LED Output 4 Output 1 L 1 2 0V Output 3 5 6 3 7 4 8 Output 2 + 24VDC 0V 3Wire Output 4 Protection Class Weight Dimensions (WxHxD) Adjacent Mounting on Bus Terminals with Power Contact Adjacent Mounting on Bus Terminals without Power Contact Passes Terminal Bus Power Passes PE Bus Agency Approvals* 32 to 131 °F (0 to 55 °C) 13 to 185 °F (-25 to 85 °C) 5% to 95%, non-condensing No corrosive gases permitted 35mm DIN rail/None conforms to EN 60068-2-6 conforms to EN 60068-2-27/ EN 60068-2-29 conforms to EN 61000-6-2/ EN61000-6-4 IP20 60g 12mm x 100mm x 68.8 mm (0.47 in x 3.94 in x 2.71 in) Yes, DC only No Yes Terminal Specifications Outputs Per Terminal Commons Per Terminal Output Type Output Data Bytes Used Output Power Source Current Consumption (from Load Voltage) Operating Voltage Maximum Load Current On Voltage Drop 30mA typical 24VDC ( -15%/+20%) 0.5 A per channel (Short-Circuit Protected) 0.4 VDC @ 0.5 A Maximum Leakage Current 300mA Maximum Inrush Current Maximum Short-Circuit Voltage Load Type Current Consumption (from I/O Bus) Reverse Voltage Protection Electrical Isolation Heat Dissipation OFF to ON Response UL/cUL File No. E157382, CE ON to OFF Response Status Indicators *To obtain the most current agency approval information, PX-244-1 4 2 Sourcing 1/2 byte (4 bits) 24VDC provided via terminal power bus No 1.5 A 35V Resistive, inductive, lamp 9mA typical No 500Vms (I/O bus/field potential) 1W max 100ms max 20ms max 4, indicates output is ON see the Agency Approval Checklist section on the specific part number’s web page. PX-244-2 $61.00 General Specifications Four-point, 2A, 24VDC Discrete Output Terminal The PX-244-2 (type 1) DC Output Terminal provides four 24VDC 2A short-circuit protected sourcing outputs with LED status. Operating Temp Storage Temp Relative Humidity Environment Air Mounting/ Orientation Restrictions Vibration Shock Noise Immunity LED Output 1 LED Output 2 LED Output 3 LED Output 4 Output 1 0V 0V Output 3 1 5 2 6 3 7 4 8 PX- 244-2 Output 2 0V L 0V Output 4 L Protection Class Weight Dimensions (WxHxD) Adjacent Mounting on Bus Terminals with Power Contact Adjacent Mounting on Bus Terminals without Power Contact Passes Terminal Bus Power Passes PE Bus Agency Approvals* 32 to 131 °F (0 to 55 °C) 13 to 185 °F (-25 to 85 °C) 5% to 95%, non-condensing No corrosive gases permitted 35mm DIN rail/None conforms to EN 60068-2-6 conforms to EN 60068-2-27/ EN 60068-2-29 conforms to EN 61000-6-2/ EN61000-6-4 IP20 60g 12mm x 100mm x 68.8 mm (0.47 in x 3.94 in x 2.71 in) Yes, DC only No Terminal Specifications Outputs Per Terminal Commons Per Terminal Output Type Output Data Bytes Used Output Power Source Current Consumption (from Load Voltage) Operating Voltage Maximum Load Current On Voltage Drop No UL/cUL File No. E157382, CE *To obtain the most current agency approval information, 30mA typical 24VDC ( -15%/+20%) 2A per channel (Short-Circuit Protected) 0.14 VDC @ 2A Maximum Leakage Current 60mA Maximum Inrush Current Maximum Short-Circuit Voltage Load Type Current Consumption (from I/O Bus) Reverse Voltage Protection Electrical Isolation Yes 4 4 Sourcing 1/2 byte (4 bits) 24VDC provided via terminal power bus Heat Dissipation OFF to ON Response 35A 52V Resistive, inductive, lamp 9mA typical Yes 500Vms (I/O bus/field potential) 1W max 160ms typ, 300ms max ON to OFF Response 10ms min, 80ms max Status Indicators 4, indicates output is ON see the Agency Approval Checklist section on the specific part number’s web page. Book 1 (14.3) eFD-34 Universal Field I/O 1-800-633-0405 Prices as of April 15, 2015. Check Web site for most current prices. Discrete Output Terminals PX-248 $63.00 General Specifications Eight-point, 0.5 A, 24VDC Discrete Output Terminal The PX-248 (type 1) DC Output Terminal provides eight 24VDC 0.5 A short-circuit protected sourcing outputs with LED stat us. Operating Temp Storage Temp Relative Humidity Environment Air Mounting/ Orientation Restrictions Vibration Shock Noise Immunity Signal LED Signal LED 2 4 6 8 1 3 5 7 Output 1 1 Output 3 2 Output 5 3 Output 7 4 5 6 7 8 (–) Output 2 Output 4 L L Output 6 Output 8 Connect common (–) to same common as terminal power bus PX-248 Protection Class Weight Dimensions (WxHxD) Adjacent Mounting on Bus Terminals with Power Contact Adjacent Mounting on Bus Terminals without Power Contact Passes Terminal Bus Power Passes PE Bus Agency Approvals* 32 to 131 °F (0 to 55 °C) 13 to 185 °F (-25 to 85 °C) 5% to 95%, non-condensing No corrosive gases permitted 35mm DIN rail/None conforms to EN 60068-2-6 conforms to EN 60068-2-27/ EN 60068-2-29 conforms to EN 61000-6-2/ EN61000-6-4 IP20 70g 12mm x 100mm x 68.8 mm (0.47 in x 3.94 in x 2.71 in) Yes, DC only Company Information Terminal Specifications Outputs Per Terminal Commons Per Terminal Output Type Output Data Bytes Used Output Power Source Current Consumption (from Load Voltage) Operating Voltage Maximum Load Current 24VDC ( -15%/+20%) 0.5 A per channel (Short-Circuit Protected) 0.4 VDC @ 0.5 A Maximum Inrush Current 1.5 A Max. Short-Circuit Voltage Load Type Current Consumption (from I/O Bus) Reverse Voltage Protection 35V Electrical Isolation Yes Heat Dissipation OFF to ON Response ON to OFF Response Status Indicators UL/cUL File No. E157382, CE 60mA + load typical On Voltage Drop Maximum Leakage Current 300mA No No 8 Field wired Sourcing 1 byte 24VDC provided via terminal power bus Resistive, inductive, lamp 18mA typical Yes 500Vms (I/O bus/field potential) 1W max 100ms max 20ms max 8, indicates output is ON General Specifications Sixteen-point, 0.5 A, 24VDC Discrete Output Terminal The PX-249 (type 1) DC Output Terminal provides sixteen 24VDC 0.5 A short-circuit protected sourcing outputs with LED status. Operating Temp Storage Temp Relative Humidity Environment Air Mounting/ Orientation Restrictions Vibration Shock PX-2 249 49 1 2 3 4 5 6 7 8 Output LED 1 2 9 10 11 12 13 14 1 15 1 16 1 3 4 5 6 7 Output 1 Output 2 9 2 10 3 11 4 12 5 13 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8 6 14 7 15 8 16 Noise Immunity Output LED 8 1 9 2 10 3 11 4 5 12 13 6 14 7 15 8 16 9 10 11 12 13 14 15 16 Output 9 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 (+) L L If external power supply, connect common (–) to same common as terminal power bus Protection Class Weight Dimensions (WxHxD) Adjacent Mounting on Bus Terminals with Power Contact Adjacent Mounting on Bus Terminals without Power Contact Passes Terminal Bus Power Passes PE Bus Agency Approvals* 32 to 131 °F (0 to 55 °C) 13 to 185 °F (-25 to 85 °C) 5% to 95%, non-condensing No corrosive gases permitted Terminal Specifications Outputs Per Terminal Commons Per Terminal Output Type Output Data Bytes Used Output Power Source Current Consumption (from Load Voltage) Operating Voltage conforms to EN 60068-2-6 conforms to EN 60068-2-27/ Maximum Load Current EN 60068-2-29 conforms to EN 61000-6-2/ On Voltage Drop 35mm DIN rail/None EN61000-6-4 IP20 70g 12mm x 100mm x 68.8 mm (0.47 in x 3.94 in x 2.71 in) Yes, DC only Maximum Inrush Current Max. Short-Circuit Voltage Load Type Current Consumption (from I/O Bus) Reverse Voltage Protection Electrical Isolation Yes Heat Dissipation OFF to ON Response ON to OFF Response Status Indicators UL/cUL File No. E157382, CE Do-More T1H PLC DirectLOGIC PLCs Overview DirectLOGIC DL05/06 DirectLOGIC DL205 DirectLOGIC DL305 DirectLOGIC DL405 Productivity Controller Overview 35mA + load typical ViewMarq Industrial Marquees 24VDC ( -15%/+20%) 0.5 A per channel (Short-Circuit Protected) 0.12 VDC @ 0.5 A C-More HMI C-More Micro HMI Other HMI Communications Appendix Book 1 3.5 A 36V Resistive, inductive, lamp 45mA typical Yes 500Vms (I/O bus/field potential) 1W max 0.45 ms 3.3 ms 16, indicates output is ON see the Agency Approval Checklist section on the specific part number’s web page. Book 1 (14.3) Universal Field I/O Universal Field I/O Software *To obtain the most current agency approval information, www.automationdirect.com/fieldIO Do-More H2 PLC 16 Field wired Sinking 2 bytes Requires external 24VDC power source Maximum Leakage Current 75mA No No Do-More PLCs Overview Productivity 3000 see the Agency Approval Checklist section on the specific part number’s web page. $89.00 CLICK PLC DirectLOGIC DL105 *To obtain the most current agency approval information, PX-249 Control Systems Overview eFD-35 Terms and Conditions Prices as of April 15, 2015. Check Web site for most current prices. Discrete Relay Output Terminals PX-272-1 $68.00 General Specifications Two-point, 0-230 VAC/VDC Discrete Solid State Relay Output Terminal The PX-272-1 (type 2) Solid State Relay Output Terminal provides two 230 VAC/ VDC 0.3 A outputs with LED status. For use with 4-wire, 3-wire and 2-wire devices. Operating Temp Storage Temp Relative Humidity Environment Air Mounting/ Orientation Restrictions Vibration Shock Noise Immunity LED Output 2 LED Output 1 Output 1 L 230 VAC / VDC 3Wire 0V PE PX X-27 -272-1 2-1 - 1 2 5 6 3 7 4 8 Output 2 230 VAC / VDC 0V 4Wire PE Note: Terminal PX-908 is recommended to isolate terminal power or use PX-970 to supply and isolate power. Protection Class Weight Dimensions (WxHxD) Adjacent Mounting on Bus Terminals with Power Contact Adjacent Mounting on Bus Terminals without Power Contact Passes Terminal Bus Power Passes PE Bus Agency Approvals* 32 to 131 °F (0 to 55 °C) Terminal Specifications 13 to 185 °F (-25 to 85 °C) Outputs Per Terminal Commons Per Terminal 5% to 95%, non-condensing Output Type No corrosive gases permitted 35mm DIN rail/None conforms to EN 60068-2-6 conforms to EN 60068-2-27/ EN 60068-2-29 conforms to EN 61000-6-2/ EN61000-6-4 Output Data Bytes Used Output Power Source 2 2 Solid State Relay (DC sourcing only) 1/4 byte (2 bits) 230 VAC/VDC provided via terminal power bus Current Consumption (ON resistance max (from Terminal Power Bus) 100mV) + load Operating Voltage 0 to 230 VAC/VDC (DC 100Hz) Maximum Load Current 0.3 A per point IP20 Maximum Leakage Current < 1mA (off state) 55g Maximum Inrush Current 0.5 A for 20s, 1.5 A for 100ms Contact Resistance 2.1 V, typical 3.2 V, max. Surge Voltage Protection Load Type Current Consumption (from I/O Bus) From 400VAC 12mm x 100mm x 68.8 mm (0.47 in x 3.94 in x 2.71 in) Yes, 230 VAC/VDC only No Electrical Isolation Yes Heat Dissipation Switch-ON Time Yes Switch-OFF Time UL/cUL File No. E157382, CE Switch-ON Delay *To obtain the most current agency approval information, Switch-OFF Delay see the Agency Approval Checklist section on the specific Status Indicators part number’s web page. Resistive, inductive 10mA 500Vms (I/O bus/field potential) 2500VDC (1 min.) 1W max 4 to 6 ms 0.05 to 0.1 ms 320ms 6.2 ms 2, indicates output is ON Book 1 (14.3) eFD-36 Universal Field I/O 1-800-633-0405 Prices as of April 15, 2015. Check Web site for most current prices. Discrete Relay Output Terminals PX-272-2 $53.00 General Specifications Operating Temp Two-point, 230VAC / 30VDC Storage Temp Discrete Relay Output Terminal Relative Humidity The PX-272-2 (type 2) Relay Output Terminal provides two 230VAC / 30VDC 5A outputs with LED status. For use with 4-wire, 3-wire and 2-wire devices. Environment Air Mounting/ Orientation Restrictions Vibration Shock Noise Immunity LED Output 1 Output 1 1 5 L 2 3Wire 6 3 4 230VAC or 30VDC 7 8 PX- 272-2 0V PE LED Output 2 1 2 5 6 3 7 4 8 Output 2 230VAC or 30VDC 0V 4Wire PE Note: Terminal PX-908 is recommended to isolate terminal power or use PX-970 to supply and isolate power. Protection Class Weight Dimensions (WxHxD) Adjacent Mounting on Bus Terminals with Power Contact Adjacent Mounting on Bus Terminals without Power Contact Passes Terminal Bus Power Passes PE Bus Agency Approvals* Company Information Terminal Specifications 13 to 185 °F (-25 to 85 °C) Outputs Per Terminal Commons Per Terminal 5% to 95%, non-condensing Output Type 32 to 131 °F (0 to 55 °C) No corrosive gases permitted 35mm DIN rail/None conforms to EN 60068-2-6 conforms to EN 60068-2-27/ EN 60068-2-29 conforms to EN 61000-6-2/ EN61000-6-4 IP20 85g 12mm x 100mm x 68.8 mm (0.47 in x 3.94 in x 2.71 in) Yes, 230VAC or 30VDC only No Output Data Bytes Used Output Power Source Current Consumption (from Terminal Power Bus) Operating Voltage Maximum Load Current Maximum Load Current with Resistive Load Maximum Load Current with Inductive Load, coswⱷ=0.4, L/R=7ms Minimum Load (approximate) Load Type Switching Times Yes Yes UL/cUL File No. E157382, CE *To obtain the most current agency approval information, see the Agency Approval Checklist section on the specific part number’s web page. Contact Material Current Consumption (from I/O Bus) Electrical Isolation Heat Dissipation Switching Frequency at Maximum Contact Load Maximum Contact Resistance Minimum Insulation Resistance 2 2 SPST Relay, normally open contact (DC sourcing only) 1/4 byte (2 bits) 230VAC/30VDC provided via terminal power bus CLICK PLC (ON resistance typ 2.4 V, max 3.2 V) + load Do-More T1H PLC 230VAC/30VDC 5A per point Do-More PLCs Overview Do-More H2 PLC DirectLOGIC PLCs Overview AC: 5A @230VAC, 1250VA DC: 5A @ 30VDC, 150W DirectLOGIC DL05/06 AC: 2A @230VAC DC: 2A @ 30VDC DirectLOGIC DL105 10mA @ 5VDC (as supplied) 100mA @ 20VDC (after approx. ≥ 100mA has been switched at least once) DirectLOGIC DL205 Reaction Time: 10ms max. Release Time; 4ms max. Bounce Time: 5ms max. DirectLOGIC DL405 Resistive, inductive, lamp Silver Cadmium Oxide 80mA 500Vms (I/O bus/field potential) 2500VDC (1 min.) 1W max 10/minute DirectLOGIC DL305 Productivity Controller Overview Productivity 3000 Universal Field I/O Software < 30mV C-More HMI 100MV @ 500VDC C-More Micro HMI switching Mechanical Operating Life 20,000,000 operations Electrical Operating Life Control Systems Overview Minimum 100,000 switching operations with resistive loads Test Voltage Between Open 750V for 1 minute Contacts 2, indicates output is ON Status Indicators ViewMarq Industrial Marquees Other HMI Communications Appendix Book 1 Terms and Conditions Book 1 (14.3) www.automationdirect.com/fieldIO Universal Field I/O eFD-37 Prices as of April 15, 2015. Check Web site for most current prices. Discrete Combination Terminal PX-549 $98.00 General Specifications Eight inputs/Eight outputs, 24VDC Discrete Input/Output Terminal The PX-549 (type 1) DC Input/Output Terminal provides eight 24VDC inputs and eight 24VDC 0.5 A outputs with reverse polarity protection and LED status. Operating Temp Storage Temp Relative Humidity Environment Air Mounting/ Orientation Restrictions Vibration Shock Noise Immunity Input LED PX-549 Output LED 1 9 10 11 12 13 14 15 16 2 1 2 3 4 9 10 11 12 3 4 5 6 7 8 5 6 7 13 14 15 16 1 Input 1 Input 2 Input 3 1 2 Input 4 Input 5 2 3 3 Input 6 4 4 5 Input 7 Input 8 5 6 6 7 7 8 8 8 1 9 2 10 3 11 4 5 12 13 6 14 7 15 8 16 Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8 24VDC Power Supply + – Connect power supply common (–) to same common as terminal power bus L L Protection Class Weight Dimensions (WxHxD) Adjacent Mounting on Bus Terminals with Power Contact Adjacent Mounting on Bus Terminals without Power Contact Passes Terminal Bus Power Passes PE Bus 32 to 131 °F (0 to 55 °C) 13 to 185 °F (-25 to 85 °C) 5% to 95%, non-condensing No corrosive gases permitted 35mm DIN rail/None Terminal Specifications Inputs/Outputs Per Terminal 8 sinking inputs / 8 sourcing outputs Data Bytes Used Input/Output Power Source 1 byte (inputs) / 1 byte (outputs) Requires external 24VDC power source Operating Voltage Rating 24VDC (-15%/+20%) conforms to EN 60068-2-6 conforms to EN 60068-2-27/ EN 60068-2-29 conforms to EN 61000-6-2/ EN61000-6-4 Current Consumption 25mA typical (from I/O Bus) Current Consumption 15mA + load typical (from Terminal Power Bus) IP20 Electrical Isolation 60g 12mm x 100mm x 68.8 mm (0.47 in x 3.94 in x 2.71 in) Yes, DC only 500Vms (I/O bus/field potential) 1W max 8 input and 8 output, indicates ON Heat Dissipation Status Indicators Input Specifications Peak Voltage Rating ON Voltage Level OFF Voltage Level No Minimum ON Current Minimum OFF Current Yes Current Consumption (from I/O Bus) No Agency Approvals* UL/cUL File No. E157382, CE OFF to ON Response ON to OFF Response *To obtain the most current agency approval information, see the Agency Approval Checklist section on the specific part number’s web page. 30VDC 15 to 30 VDC -3 to +5 VDC 2mA 40mA 3mA typical 3ms 3ms Output Specifications Max. Load Current per Output On Voltage Drop Maximum Leakage Current 0.5 A (Short-Circuit Protected) Maximum Inrush Current 2A 0.14 VDC @ 2A 5mA Maximum Short-Circuit 45V Voltage Resistive, inductive, lamp Load Type Reverse Voltage Protection Yes OFF to ON Response 50ms ON to OFF Response 75ms Book 1 (14.3) eFD-38 Universal Field I/O 1-800-633-0405 Prices as of April 15, 2015. Check Web site for most current prices. System Installation and Removal Bus Coupler and Bus Terminal Installation Bus Coupler Installation: 2 1. Attach a Bus Coupler by snapping it onto 35mm DIN rail and securing it into position using the DIN rail locking wheel (where applicable) located on the left side of the coupler. Insert unit using tongue and groove ntil molded guide and press gently until it becomes firmly seated on DIN rail. ra ail. Where applicable, rotate Locking Wheel to lock Bus Coupler Bus Terminal Installation: 2.  To add a bus terminal, insert unit onto right side of Bus Coupler using the tongue and groove at the top and bottom of the unit, pressing gently until it snaps onto the DIN rail. A proper connection cannot be made by sliding the units together on the DIN rail. When correctly installed, no significant gap can be seen between the attached units. Bus connection is made through the six slide contacts located on the upper right side of the units. Add up to 64 bus terminals per Bus Coupler, including a bus end terminal. 1 Align tab with molded guide Wiring Connections Wire connection is made through a spring clamp style terminal. This terminal is designed for a single-conductor solid or stranded wire. Wire connection is made by firmly pushing the screwdriver into the screwdriver slot, inserting the wire into the wire slot and removing the screwdriver, locking the wire into position. S Screwdriver Slot S Wire Slot Removing Bus Coupler and Bus Terminals Wiring Specifications Connection Type Spring Clamp Terminals Wire Gauge/Wire Cross Section* 28-14 AWG / 0.08 - 2.5 mm2 Screwdriver Width 2.5 mm (0.10) such as our TW-SD-MSL-2 Wire Stripping Length 8mm * For Thermocouple terminals, a thermocouple extension wire is recommended Where applicable, rotate Locking Wheel to unlock Bus Coupler A locking mechanism prevents individual units from being pulled off. For bus terminal removal, pull the orange DIN rail release tab firmly to unlatch the unit from the rail. If attached to other terminal units, slide unit forward until released. For Bus Couplers with locking wheels, release the DIN rail locking wheel, then pull firmly on DIN rail release tab. Firmly pull DIN Rail Release Tab to unlatch unit from rail. Book 1 (14.3) eFD-24 Universal Field I/O 1-800-633-0405 Prices as of April 15, 2015. Check Web site for most current prices. Installation Considerations Company Information Control Systems Overview Terminal Dimensions and Spacing Requirements CLICK PLC 1.4” 35mm min Use the following diagrams to make sure the Protos X system can be installed in your application. Protos X terminals require 35mm DIN rail for mounting; there are no orientation restrictions. Do-More PLCs Overview 0.8” 20mm min Do-More H2 PLC To ensure proper airflow for cooling purposes, units should be spaced, at a minimum, as shown. It is also important to check the Protos X dimensions against the conditions required for your application. Do-More T1H PLC 0.8” 20mm min 1.4” 35mm min DirectLOGIC PLCs Overview DirectLOGIC DL05/06 DirectLOGIC DL105 1.4” 35mm min DirectLOGIC DL205 DirectLOGIC DL305 1.4” 35mm min DirectLOGIC DL405 Productivity Controller Overview Productivity 3000 See the Enclosures section for an enclosure that may be suitable for your application Universal Field I/O Software C-More HMI PX-TCP2 PX-TCP1 / X MOD PX-MOD PX PX-903 903 PX-902 Standard Terminal C-More Micro HMI ViewMarq Industrial Marquees Ethernet TCP/IP COM 1 2 3 4 ERROR WDG Us GNDs G 100 mm [3.94”] 4”] I/I/O /O RUN I/I/O /O ERR 5 1 5 Up 2 6 2 6 GNDp 3 7 3 7 4 8 4 8 TM DIP 1 2 3 4 5 6 7 8 PE PE 1 2 ON 44 m mm m [1.73”] 3”] PX-TCP1 PX TCP11 PX-903 24 5 mm 24.5 [.96”] [ 96 96”]] Terms and Conditions PX-902 P X-90 02 0 2 27.5 mm [.96”] [.96 ] 12 mm [.47”] 68.8 mm [2.71”] Book 1 (14.3) www.automationdirect.com/fieldIO Communications Appendix Book 1 PE PPEE .PE 51 mm m [2.01”]] 100 mm [3.94”] + + ON 1 2 3 4 5 6 7 8 9 10 ON TCP2 PX-TCP2 1 + + TM Other HMI 24V 0V 24VV 00V Universal Field I/O eFD-25 TM Prices as of April 15, 2015. Check Web site for most current prices. Installation Considerations Terminal Types 8 TYPE 2 Terminal power bus contact Terminal power bus contact 1 5 2 6 3 7 4 8 TYPE 3 I/O Bus contacts I/O Bus contacts T Terminal p power bus pass b th h through Terminal power bus contact Terminal T power p bus pass b through th h Terminal power bus contact Terminal PE bus contact Type 1: This terminal passes the terminal power bus from the preceding terminal to the next terminal and therefore it must be mounted to a preceding terminal that passes bus power. 1 5 2 6 3 7 4 8 Terminal power bus pass through Terminal power bus pass through Terminal PE bus pass through Type 2: This terminal passes the terminal power bus and PE from the preceding terminal to the next terminal and therefore it must be preceded by a terminal that passes both terminal power bus and PE. TYPE 4 I/O Bus contacts I/O B conta 1 5 1 5 2 6 2 6 3 7 4 8 3 7 4 8 Note, bus contacts do not exist on this module Note, bus and pass through contacts do not exist on this module Type 3: This terminal does not pass the terminal power bus or PE and can be preceded by any terminal, however it will interrupt the terminal power bus and PE. Five Basic Terminal Types PX-970 P PX X-970 TYPE 3 I/O Bus contacts I/O Bus contacts Terminal power bus pass through Terminal power bus pass through Terminal PE bus pass through inal passes the us and PE from the al to the next termiit must be precedhat passes both us and PE. TYPE 4 1 5 1 5 2 6 2 6 3 7 4 8 3 7 4 8 Note, bus contacts do not exist on this module Note, bus and pass through contacts do not exist on this module Type 3: This terminal does not pass the terminal power bus or PE and can be preceded by any terminal, however it will interrupt the terminal power bus and PE. TYPE 5 I/O Bus contacts PX-970 P PX X-970 I/O Bus contacts Terminal power bus supply Terminal power bus supply Terminal power bus supply Type 4: This terminal requires external voltage connection and supplies the terminal power bus to terminals located to its right. The terminals to its right must support the same power bus of 120/230 VAC or 24VDC. This terminal will not pass terminal power or PE from any preceding terminals. Note, bus and pass through contacts do not exist on this module Type 5: This terminal is used to separate the terminal power bus and PE from other terminals and can mounted next to any terminal. Book 1 (14.3) eFD-26 Universal Field I/O Termi power bus su Termi power bus su Termi power bus su Type 4: This terminal requires exte nal voltage connection and supplie the terminal power bus to terminal located to its right. The terminals t right must support the same powe bus of 120/230 VAC or 24VDC. Th terminal will not pass terminal pow or PE from any preceding terminal Protos XTM is a trademark of Automationdirect.com Incorporated 5 7 TM TYPE 1 PE 2 6 Protos X Five Basic Terminal Ty 1-800-633-0405