Discrete Input Terminals PX-144
$34.00
General Specifications
Four-point, 24VDC Discrete Input Terminal The PX-144 (type 1) DC Input Terminal provides four electrically isolated 24VDC sinking inputs with LED status. For use with 3-wire and 2-wire sensors.
Operating Temp Storage Temp Relative Humidity Environment Air Mounting/ Orientation Restrictions Vibration Shock Noise Immunity
LED Input 1
LED Input 2
LED Input 3
LED Input 4
Input 1
1
5
+24VDC 2
6
3
4
7
Input 3
1
5
2
6
3
7
4
8
Input 2 +24VDC 3Wire
0V Input 4
8
PX-144
32 to 131 °F (0 to 55 °C) 13 to 185 °F (-25 to 85 °C) 5% to 95%, non-condensing No corrosive gases permitted 35mm DIN rail/None conforms to EN 60068-2-6 conforms to EN 60068-2-27/ EN 60068-2-29 conforms to EN 61000-6-2/ EN61000-6-4
Protection Class Weight Dimensions (WxHxD) Adjacent Mounting on Bus Terminals with Power Contact Adjacent Mounting on Bus Terminals without Power Contact Passes Terminal Bus Power
IP20
Passes PE Bus
No
55g 12mm x 100mm x 68.8 mm (0.47 in x 3.94 in x 2.71 in) Yes, DC only
No
Company Information
Terminal Specifications Inputs Per Terminal Input Type Input Data Bytes Used Input Power Source Current Consumption (from Terminal Power Bus) Operating Voltage Rating Peak Voltage Rating ON Voltage Level OFF Voltage Level Minimum ON Current Maximum OFF Current Current Consumption (from I/O Bus) Electrical Isolation Heat Dissipation OFF to ON Response ON to OFF Response Status Indicators
4 Sinking 1/2 byte (4 bits) 24VDC provided via terminal power bus 5mA typical 24VDC (-15%/+20%) 30VDC 15 to 30 VDC -3 to +5 VDC 50mA 100mA 5mA typical 500Vms (I/O bus/field potential) 1W max 3ms 3ms 4, indicates input is ON
Eight-point, 24VDC Discrete Input Terminal The PX-148 (type 1) DC Input Terminal provides eight electrically isolated 24VDC sinking inputs with LED status.
Operating Temp Storage Temp Relative Humidity Environment Air Mounting/ Orientation Restrictions Vibration Shock Noise Immunity
Signal LED
Signal LED
2 4 6 8
1 3 5 7
Input 1 Input 3 Input 5 Input 7
PX-148
1
5
2
6
3
7
4
8
Input 2 Input 4 Input 6 Input 8
24 VDC Power Supply
+ – Connect power supply common (–) to same common as terminal power bus
Protection Class Weight Dimensions (WxHxD)
32 to 131 °F (0 to 55 °C) 13 to 185 °F (-25 to 85 °C) 5% to 95%, non-condensing No corrosive gases permitted 35mm DIN rail/None conforms to EN 60068-2-6 conforms to EN 60068-2-27/ EN 60068-2-29 conforms to EN 61000-6-2/ EN61000-6-4 IP20 55g 12mm x 100mm x 68.8 mm (0.47 in x 3.94 in x 2.71 in)
Adjacent Mounting on Bus Terminals Yes, DC only with Power Contact Adjacent Mounting on Bus Terminals No without Power Contact Passes Terminal Yes Bus Power
Do-More T1H PLC DirectLOGIC PLCs Overview DirectLOGIC DL05/06 DirectLOGIC DL105 DirectLOGIC DL205 DirectLOGIC DL305
Universal Field I/O
Terminal Specifications Inputs Per Terminal Input Type Input Data Bytes Used Input Power Source Current Consumption (from Terminal Power Bus) Operating Voltage Rating Peak Voltage Rating ON Voltage Level OFF Voltage Level Minimum ON Current Maximum OFF Current Current Consumption (from I/O Bus) Electrical Isolation Heat Dissipation OFF to ON Response ON to OFF Response Status Indicators
8 Sinking 1 byte Requires external 24VDC power source 2mA + load, typical 24VDC (-15%/+20%) 30VDC 15 to 30 VDC -3 to +5 VDC 2mA 1.5 mA 5mA typical 500Vms (I/O bus/field potential) 1W max 3ms 3ms 8, indicates input is ON
No Passes PE Bus Agency Approvals* UL/cUL File No. E157382, CE *To obtain the most current agency approval information,
see the Agency Approval Checklist section on the specific part number’s web page.
www.automationdirect.com/fieldIO
Do-More H2 PLC
Productivity 3000
see the Agency Approval Checklist section on the specific part number’s web page.
General Specifications
Do-More PLCs Overview
Productivity Controller Overview
Yes
Agency Approvals* UL/cUL File No. E157382, CE
$55.00
CLICK PLC
DirectLOGIC DL405
*To obtain the most current agency approval information,
PX-148
Control Systems Overview
Book 1 (14.3)
Universal Field I/O
eFD-31
Software C-More HMI C-More Micro HMI ViewMarq Industrial Marquees Other HMI Communications Appendix Book 1 Terms and Conditions
Prices as of April 15, 2015. Check Web site for most current prices.
Discrete Input Terminals PX-149
$95.00
General Specifications Operating Temp Storage Temp Relative Humidity Environment Air Mounting/ Orientation Restrictions Vibration
Sixteen-point, 24VDC Discrete Input Terminal The PX-149 (type 1) DC Input Terminal provides sixteen electrically isolated 24VDC sinking inputs with LED status.
Shock Noise Immunity
PX-149 1
Input LED 1 3
10
3
4
11 12
4 5
5
6
13
6
7
14 15 16
7 8 1
9 10 11 2 13 14 15 16
2
9
2
Input LED
Input 1 Input 2
9
2
10
3
11
4
12
5
13
6
14
7
15
8
16
Input 3 Input 4 Input 5 Input 6 Input 7 Input 8
8
1
9
2
10
3
11
4 5
12 13
6
14
7
15
8
16
24 VDC Power Supply +
Input 9
–
Input 10 Input 11
Connect power supply common (–) to same common as terminal power bus
Input 12 Input 13 Input 14 Input 15 Input 16
Protection Class Weight Dimensions (WxHxD)
32 to 131 °F (0 to 55 °C) 13 to 185 °F (-25 to 85 °C) 5% to 95%, non-condensing
Input Power Source Current Consumption 35mm DIN rail/None (from Terminal Power Bus) Operating Voltage Rating conforms to EN 60068-2-6 Peak Voltage Rating conforms to EN 60068-2-27/ ON Voltage Level EN 60068-2-29 OFF Voltage Level conforms to EN 61000-6-2/ EN61000-6-4 Minimum ON Current Maximum OFF Current IP20 Current Consumption 60g (from I/O Bus) No corrosive gases permitted
12mm x 100mm x 68.8 mm (0.47 in x 3.94 in x 2.71 in)
Adjacent Mounting on Bus Terminals Yes, DC only with Power Contact Adjacent Mounting on Bus Terminals without Power Contact Passes Terminal Bus Power Passes PE Bus Agency Approvals*
Terminal Specifications Inputs Per Terminal Input Type Input Data Bytes Used
Electrical Isolation Heat Dissipation OFF to ON Response ON to OFF Response Status Indicators
16 Sinking 2 bytes Requires external 24VDC power source NA 24VDC (-15%/+20%) 30VDC 11 to 30 VDC -3 to +5 VDC 2mA 40mA 20mA typical 500Vms (I/O bus/field potential) 1W max 3ms 3ms 16, indicates input is ON
No
Yes No UL/cUL File No. E157382, CE
*To obtain the most current agency approval information,
see the Agency Approval Checklist section on the specific part number’s web page.
PX-172-1
$36.00
General Specifications
Two-point, 120-230 VAC Discrete Input Terminal The PX-172-1 (type 2) DC Input Terminal provides two electrically isolated 120-230 VAC inputs with LED status. For use with 4-wire, 3-wire and 2-wire devices.
Operating Temp Storage Temp Relative Humidity Environment Air Mounting/ Orientation Restrictions Vibration Shock Noise Immunity
LED Input 2
LED Input 1
Input 1 120230 VAC 3Wire
0V PE
1 2
5 6
3
7
4
8
Input 2 120230 VAC 0V
4Wire
PE
Note: Terminal PX-908 is recommended to isolate terminal power or use PX-970 to supply and isolate power.
PX-172-1
Protection Class Weight Dimensions (WxHxD) Adjacent Mounting on Bus Terminals with Power Contact Adjacent Mounting on Bus Terminals without Power Contact Passes Terminal Bus Power Passes PE Bus Agency Approvals*
32 to 131 °F (0 to 55 °C) 13 to 185 °F (-25 to 85 °C) 5% to 95%, non-condensing
Terminal Specifications Inputs Per Terminal Input Type Input Data Bytes Used
2 NA 1/4 byte (2 bits)
Input Power Source
Requires external 120-230 VAC power source. PX-908 terminal recommended to provide power to the terminal power bus.
No corrosive gases permitted 35mm DIN rail/None conforms to EN 60068-2-6 conforms to EN 60068-2-27/ EN 60068-2-29 conforms to EN 61000-6-2/ EN61000-6-4 IP20 60g 12mm x 100mm x 68.8 mm (0.47 in x 3.94 in x 2.71 in) Yes, AC only
Current Consumption (from Terminal Power Bus) Operating Voltage Rating Peak Voltage Rating ON Voltage Level OFF Voltage Level Minimum ON Current Maximum OFF Current Current Consumption (from I/O Bus) Electrical Isolation
No
Yes
Heat Dissipation OFF to ON Response ON to OFF Response Status Indicators
6mA typical 120 to 230 VAC 260VAC 79 to 260 VAC 0 to 40 VAC 250mA 500mA 3mA typical 500Vms (I/O bus/field potential) 1W max 10ms 10ms 2, indicates input is ON
Yes UL/cUL File No. E157382, CE
*To obtain the most current agency approval information,
see the Agency Approval Checklist section on the specific part number’s web page.
Book 1 (14.3)
eFD-32
Universal Field I/O
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
Discrete Input Terminals PX-172-2
$36.00
General Specifications
Two-point, 120 VAC/VDC Discrete Input Terminal The PX-172-2 (type 2) DC Input Terminal provides two electrically isolated 120 VAC/VDC inputs with LED status. For use with 4-wire, 3-wire and 2-wire devices.
Operating Temp Storage Temp Relative Humidity Environment Air Mounting/ Orientation Restrictions Vibration Shock Noise Immunity
LED Input 2
LED Input 1
Input 1 120 VAC/ VDC 3Wire
0V PE
1 2
5 6
3
7
4
8
Input 2 120 VAC/ VDC 0V
4Wire
PE
Note: Terminal PX-908 is recommended to isolate terminal power or use PX-970 to supply and isolate power.
PX-172
32 to 131 °F (0 to 55 °C) 13 to 185 °F (-25 to 85 °C) 5% to 95%, non-condensing
Company Information
Terminal Specifications Inputs Per Terminal Input Type Input Data Bytes Used
2 NA 1/4 byte (2 bits)
Input Power Source
Requires external 120 VAC/VDC power source. PX-908 terminal recommended to provide power to the terminal power bus.
No corrosive gases permitted 35mm DIN rail/None conforms to EN 60068-2-6 conforms to EN 60068-2-27/ EN 60068-2-29 conforms to EN 61000-6-2/ EN61000-6-4
Protection Class Weight Dimensions (WxHxD) Adjacent Mounting on Bus Terminals with Power Contact Adjacent Mounting on Bus Terminals without Power Contact Passes Terminal Bus Power
IP20
Passes PE Bus
Yes
60g 12mm x 100mm x 68.8 mm (0.47 in x 3.94 in x 2.71 in) Yes, 120 VAC/VDC only
No
Yes
Current Consumption (from Terminal Power Bus) Operating Voltage Rating Peak Voltage Rating ON Voltage Level OFF Voltage Level Minimum ON Current Maximum OFF Current Current Consumption (from I/O Bus) Electrical Isolation Heat Dissipation OFF to ON Response ON to OFF Response Status Indicators
6mA typical
Control Systems Overview CLICK PLC Do-More PLCs Overview Do-More H2 PLC Do-More T1H PLC
120 VAC/VDC 140 VAC/VDC 80 to 140 VAC/VDC 0 to 40 VAC/VDC 250mA 500mA
DirectLOGIC PLCs Overview
3mA typical
DirectLOGIC DL205
500Vms (I/O bus/field potential) 1W max 10ms 10ms 2, indicates input is ON
DirectLOGIC DL05/06 DirectLOGIC DL105
DirectLOGIC DL305 DirectLOGIC DL405 Productivity Controller Overview Productivity 3000
Agency Approvals* UL/cUL File No. E157382, CE *To obtain the most current agency approval information,
Universal Field I/O
see the Agency Approval Checklist section on the specific part number’s web page.
Software C-More HMI C-More Micro HMI ViewMarq Industrial Marquees Other HMI Communications Appendix Book 1 Terms and Conditions
Book 1 (14.3)
www.automationdirect.com/fieldIO
Universal Field I/O
eFD-33
Prices as of April 15, 2015. Check Web site for most current prices.
Discrete Output Terminals PX-244-1
$51.00
General Specifications
Four-point, 0.5 A, 24VDC Discrete Output Terminal The PX-244-1 (type 1) DC Output Terminal provides four 24VDC 0.5 A short-circuit protected sourcing outputs with LED status. For use with 3-wire and 2-wire devices.
Operating Temp Storage Temp Relative Humidity Environment Air Mounting/ Orientation Restrictions Vibration Shock Noise Immunity
LED Output 1
LED Output 2
LED Output 3
LED Output 4
Output 1
L
1 2
0V Output 3
5 6
3
7
4
8
Output 2 + 24VDC 0V
3Wire
Output 4
Protection Class Weight Dimensions (WxHxD) Adjacent Mounting on Bus Terminals with Power Contact Adjacent Mounting on Bus Terminals without Power Contact Passes Terminal Bus Power Passes PE Bus Agency Approvals*
32 to 131 °F (0 to 55 °C) 13 to 185 °F (-25 to 85 °C) 5% to 95%, non-condensing No corrosive gases permitted 35mm DIN rail/None conforms to EN 60068-2-6 conforms to EN 60068-2-27/ EN 60068-2-29 conforms to EN 61000-6-2/ EN61000-6-4 IP20 60g 12mm x 100mm x 68.8 mm (0.47 in x 3.94 in x 2.71 in) Yes, DC only
No
Yes
Terminal Specifications Outputs Per Terminal Commons Per Terminal Output Type Output Data Bytes Used Output Power Source Current Consumption (from Load Voltage) Operating Voltage Maximum Load Current On Voltage Drop
30mA typical 24VDC ( -15%/+20%) 0.5 A per channel (Short-Circuit Protected) 0.4 VDC @ 0.5 A
Maximum Leakage Current 300mA Maximum Inrush Current Maximum Short-Circuit Voltage Load Type Current Consumption (from I/O Bus) Reverse Voltage Protection Electrical Isolation
Heat Dissipation OFF to ON Response UL/cUL File No. E157382, CE ON to OFF Response Status Indicators *To obtain the most current agency approval information,
PX-244-1
4 2 Sourcing 1/2 byte (4 bits) 24VDC provided via terminal power bus
No
1.5 A 35V Resistive, inductive, lamp 9mA typical No 500Vms (I/O bus/field potential) 1W max 100ms max 20ms max 4, indicates output is ON
see the Agency Approval Checklist section on the specific part number’s web page.
PX-244-2
$61.00
General Specifications
Four-point, 2A, 24VDC Discrete Output Terminal The PX-244-2 (type 1) DC Output Terminal provides four 24VDC 2A short-circuit protected sourcing outputs with LED status.
Operating Temp Storage Temp Relative Humidity Environment Air Mounting/ Orientation Restrictions Vibration Shock Noise Immunity
LED Output 1
LED Output 2
LED Output 3
LED Output 4
Output 1 0V 0V Output 3
1
5
2
6
3
7
4
8
PX- 244-2
Output 2 0V
L
0V Output 4
L
Protection Class Weight Dimensions (WxHxD) Adjacent Mounting on Bus Terminals with Power Contact Adjacent Mounting on Bus Terminals without Power Contact Passes Terminal Bus Power Passes PE Bus Agency Approvals*
32 to 131 °F (0 to 55 °C) 13 to 185 °F (-25 to 85 °C) 5% to 95%, non-condensing No corrosive gases permitted 35mm DIN rail/None conforms to EN 60068-2-6 conforms to EN 60068-2-27/ EN 60068-2-29 conforms to EN 61000-6-2/ EN61000-6-4 IP20 60g 12mm x 100mm x 68.8 mm (0.47 in x 3.94 in x 2.71 in) Yes, DC only
No
Terminal Specifications Outputs Per Terminal Commons Per Terminal Output Type Output Data Bytes Used Output Power Source Current Consumption (from Load Voltage) Operating Voltage Maximum Load Current On Voltage Drop
No UL/cUL File No. E157382, CE
*To obtain the most current agency approval information,
30mA typical 24VDC ( -15%/+20%) 2A per channel (Short-Circuit Protected) 0.14 VDC @ 2A
Maximum Leakage Current 60mA Maximum Inrush Current Maximum Short-Circuit Voltage Load Type Current Consumption (from I/O Bus) Reverse Voltage Protection Electrical Isolation
Yes
4 4 Sourcing 1/2 byte (4 bits) 24VDC provided via terminal power bus
Heat Dissipation OFF to ON Response
35A 52V Resistive, inductive, lamp 9mA typical Yes 500Vms (I/O bus/field potential) 1W max 160ms typ, 300ms max
ON to OFF Response
10ms min, 80ms max
Status Indicators
4, indicates output is ON
see the Agency Approval Checklist section on the specific part number’s web page.
Book 1 (14.3)
eFD-34
Universal Field I/O
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
Discrete Output Terminals PX-248
$63.00
General Specifications
Eight-point, 0.5 A, 24VDC Discrete Output Terminal The PX-248 (type 1) DC Output Terminal provides eight 24VDC 0.5 A short-circuit protected sourcing outputs with LED stat us.
Operating Temp Storage Temp Relative Humidity Environment Air Mounting/ Orientation Restrictions Vibration Shock Noise Immunity
Signal LED
Signal LED
2 4 6 8
1 3 5 7
Output 1
1
Output 3
2
Output 5
3
Output 7
4
5 6 7 8
(–)
Output 2 Output 4
L L
Output 6 Output 8
Connect common (–) to same common as terminal power bus
PX-248
Protection Class Weight Dimensions (WxHxD) Adjacent Mounting on Bus Terminals with Power Contact Adjacent Mounting on Bus Terminals without Power Contact Passes Terminal Bus Power Passes PE Bus Agency Approvals*
32 to 131 °F (0 to 55 °C) 13 to 185 °F (-25 to 85 °C) 5% to 95%, non-condensing No corrosive gases permitted 35mm DIN rail/None conforms to EN 60068-2-6 conforms to EN 60068-2-27/ EN 60068-2-29 conforms to EN 61000-6-2/ EN61000-6-4 IP20 70g 12mm x 100mm x 68.8 mm (0.47 in x 3.94 in x 2.71 in) Yes, DC only
Company Information
Terminal Specifications Outputs Per Terminal Commons Per Terminal Output Type Output Data Bytes Used Output Power Source Current Consumption (from Load Voltage) Operating Voltage Maximum Load Current
24VDC ( -15%/+20%) 0.5 A per channel (Short-Circuit Protected) 0.4 VDC @ 0.5 A
Maximum Inrush Current
1.5 A
Max. Short-Circuit Voltage Load Type Current Consumption (from I/O Bus) Reverse Voltage Protection
35V
Electrical Isolation
Yes
Heat Dissipation OFF to ON Response ON to OFF Response Status Indicators
UL/cUL File No. E157382, CE
60mA + load typical
On Voltage Drop Maximum Leakage Current 300mA
No
No
8 Field wired Sourcing 1 byte 24VDC provided via terminal power bus
Resistive, inductive, lamp 18mA typical Yes 500Vms (I/O bus/field potential) 1W max 100ms max 20ms max 8, indicates output is ON
General Specifications
Sixteen-point, 0.5 A, 24VDC Discrete Output Terminal The PX-249 (type 1) DC Output Terminal provides sixteen 24VDC 0.5 A short-circuit protected sourcing outputs with LED status.
Operating Temp Storage Temp Relative Humidity Environment Air Mounting/ Orientation Restrictions Vibration Shock
PX-2 249 49 1 2 3 4 5 6 7 8
Output LED 1
2
9 10 11 12 13 14 1 15 1 16 1
3
4
5
6
7
Output 1 Output 2
9
2
10
3
11
4
12
5
13
Output 3 Output 4 Output 5 Output 6 Output 7 Output 8
6
14
7
15
8
16
Noise Immunity
Output LED
8
1
9
2
10
3
11
4 5
12 13
6
14
7
15
8
16
9 10 11 12 13 14 15 16
Output 9 Output 10
Output 11 Output 12 Output 13 Output 14 Output 15 Output 16
(+)
L L If external power supply, connect common (–) to same common as terminal power bus
Protection Class Weight Dimensions (WxHxD) Adjacent Mounting on Bus Terminals with Power Contact Adjacent Mounting on Bus Terminals without Power Contact Passes Terminal Bus Power Passes PE Bus Agency Approvals*
32 to 131 °F (0 to 55 °C) 13 to 185 °F (-25 to 85 °C) 5% to 95%, non-condensing No corrosive gases permitted
Terminal Specifications Outputs Per Terminal Commons Per Terminal Output Type Output Data Bytes Used Output Power Source
Current Consumption (from Load Voltage) Operating Voltage conforms to EN 60068-2-6 conforms to EN 60068-2-27/ Maximum Load Current EN 60068-2-29 conforms to EN 61000-6-2/ On Voltage Drop 35mm DIN rail/None
EN61000-6-4 IP20 70g
12mm x 100mm x 68.8 mm (0.47 in x 3.94 in x 2.71 in) Yes, DC only
Maximum Inrush Current Max. Short-Circuit Voltage Load Type Current Consumption (from I/O Bus) Reverse Voltage Protection Electrical Isolation
Yes
Heat Dissipation OFF to ON Response ON to OFF Response Status Indicators
UL/cUL File No. E157382, CE
Do-More T1H PLC DirectLOGIC PLCs Overview DirectLOGIC DL05/06
DirectLOGIC DL205 DirectLOGIC DL305 DirectLOGIC DL405 Productivity Controller Overview
35mA + load typical
ViewMarq Industrial Marquees
24VDC ( -15%/+20%) 0.5 A per channel (Short-Circuit Protected) 0.12 VDC @ 0.5 A
C-More HMI C-More Micro HMI
Other HMI Communications Appendix Book 1
3.5 A 36V Resistive, inductive, lamp 45mA typical Yes 500Vms (I/O bus/field potential) 1W max 0.45 ms 3.3 ms 16, indicates output is ON
see the Agency Approval Checklist section on the specific part number’s web page.
Book 1 (14.3)
Universal Field I/O
Universal Field I/O Software
*To obtain the most current agency approval information,
www.automationdirect.com/fieldIO
Do-More H2 PLC
16 Field wired Sinking 2 bytes Requires external 24VDC power source
Maximum Leakage Current 75mA
No
No
Do-More PLCs Overview
Productivity 3000
see the Agency Approval Checklist section on the specific part number’s web page.
$89.00
CLICK PLC
DirectLOGIC DL105
*To obtain the most current agency approval information,
PX-249
Control Systems Overview
eFD-35
Terms and Conditions
Prices as of April 15, 2015. Check Web site for most current prices.
Discrete Relay Output Terminals PX-272-1
$68.00
General Specifications
Two-point, 0-230 VAC/VDC Discrete Solid State Relay Output Terminal The PX-272-1 (type 2) Solid State Relay Output Terminal provides two 230 VAC/ VDC 0.3 A outputs with LED status. For use with 4-wire, 3-wire and 2-wire devices.
Operating Temp Storage Temp Relative Humidity Environment Air Mounting/ Orientation Restrictions Vibration Shock Noise Immunity
LED Output 2
LED Output 1
Output 1
L
230 VAC / VDC 3Wire
0V PE
PX X-27 -272-1 2-1 -
1 2
5 6
3
7
4
8
Output 2 230 VAC / VDC
0V
4Wire
PE
Note: Terminal PX-908 is recommended to isolate terminal power or use PX-970 to supply and isolate power.
Protection Class Weight Dimensions (WxHxD) Adjacent Mounting on Bus Terminals with Power Contact Adjacent Mounting on Bus Terminals without Power Contact Passes Terminal Bus Power Passes PE Bus Agency Approvals*
32 to 131 °F (0 to 55 °C)
Terminal Specifications
13 to 185 °F (-25 to 85 °C)
Outputs Per Terminal Commons Per Terminal
5% to 95%, non-condensing
Output Type
No corrosive gases permitted 35mm DIN rail/None conforms to EN 60068-2-6 conforms to EN 60068-2-27/ EN 60068-2-29 conforms to EN 61000-6-2/ EN61000-6-4
Output Data Bytes Used Output Power Source
2 2 Solid State Relay (DC sourcing only) 1/4 byte (2 bits) 230 VAC/VDC provided via terminal power bus
Current Consumption (ON resistance max (from Terminal Power Bus) 100mV) + load Operating Voltage
0 to 230 VAC/VDC (DC 100Hz)
Maximum Load Current
0.3 A per point
IP20
Maximum Leakage Current < 1mA (off state)
55g
Maximum Inrush Current
0.5 A for 20s, 1.5 A for 100ms
Contact Resistance
2.1 V, typical 3.2 V, max.
Surge Voltage Protection Load Type Current Consumption (from I/O Bus)
From 400VAC
12mm x 100mm x 68.8 mm (0.47 in x 3.94 in x 2.71 in) Yes, 230 VAC/VDC only
No
Electrical Isolation Yes
Heat Dissipation Switch-ON Time Yes Switch-OFF Time UL/cUL File No. E157382, CE Switch-ON Delay *To obtain the most current agency approval information, Switch-OFF Delay see the Agency Approval Checklist section on the specific Status Indicators part number’s web page.
Resistive, inductive 10mA 500Vms (I/O bus/field potential) 2500VDC (1 min.) 1W max 4 to 6 ms 0.05 to 0.1 ms 320ms 6.2 ms 2, indicates output is ON
Book 1 (14.3)
eFD-36
Universal Field I/O
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
Discrete Relay Output Terminals PX-272-2
$53.00
General Specifications
Operating Temp
Two-point, 230VAC / 30VDC Storage Temp Discrete Relay Output Terminal Relative Humidity The PX-272-2 (type 2) Relay Output Terminal provides two 230VAC / 30VDC 5A outputs with LED status. For use with 4-wire, 3-wire and 2-wire devices.
Environment Air Mounting/ Orientation Restrictions Vibration Shock Noise Immunity
LED Output 1
Output 1 1
5
L 2
3Wire
6
3
4
230VAC or 30VDC
7
8
PX- 272-2
0V PE
LED Output 2
1 2
5 6
3
7
4
8
Output 2 230VAC or 30VDC
0V
4Wire
PE
Note: Terminal PX-908 is recommended to isolate terminal power or use PX-970 to supply and isolate power.
Protection Class Weight Dimensions (WxHxD) Adjacent Mounting on Bus Terminals with Power Contact Adjacent Mounting on Bus Terminals without Power Contact Passes Terminal Bus Power Passes PE Bus Agency Approvals*
Company Information
Terminal Specifications
13 to 185 °F (-25 to 85 °C)
Outputs Per Terminal Commons Per Terminal
5% to 95%, non-condensing
Output Type
32 to 131 °F (0 to 55 °C)
No corrosive gases permitted 35mm DIN rail/None conforms to EN 60068-2-6 conforms to EN 60068-2-27/ EN 60068-2-29 conforms to EN 61000-6-2/ EN61000-6-4 IP20 85g 12mm x 100mm x 68.8 mm (0.47 in x 3.94 in x 2.71 in) Yes, 230VAC or 30VDC only
No
Output Data Bytes Used Output Power Source Current Consumption (from Terminal Power Bus) Operating Voltage Maximum Load Current Maximum Load Current with Resistive Load Maximum Load Current with Inductive Load, coswⱷ=0.4, L/R=7ms Minimum Load (approximate) Load Type Switching Times
Yes Yes UL/cUL File No. E157382, CE
*To obtain the most current agency approval information,
see the Agency Approval Checklist section on the specific part number’s web page.
Contact Material Current Consumption (from I/O Bus) Electrical Isolation Heat Dissipation Switching Frequency at Maximum Contact Load Maximum Contact Resistance Minimum Insulation Resistance
2 2 SPST Relay, normally open contact (DC sourcing only) 1/4 byte (2 bits) 230VAC/30VDC provided via terminal power bus
CLICK PLC
(ON resistance typ 2.4 V, max 3.2 V) + load
Do-More T1H PLC
230VAC/30VDC 5A per point
Do-More PLCs Overview Do-More H2 PLC
DirectLOGIC PLCs Overview
AC: 5A @230VAC, 1250VA DC: 5A @ 30VDC, 150W
DirectLOGIC DL05/06
AC: 2A @230VAC DC: 2A @ 30VDC
DirectLOGIC DL105
10mA @ 5VDC (as supplied) 100mA @ 20VDC (after approx. ≥ 100mA has been switched at least once)
DirectLOGIC DL205
Reaction Time: 10ms max. Release Time; 4ms max. Bounce Time: 5ms max.
DirectLOGIC DL405
Resistive, inductive, lamp
Silver Cadmium Oxide 80mA 500Vms (I/O bus/field potential) 2500VDC (1 min.) 1W max 10/minute
DirectLOGIC DL305
Productivity Controller Overview Productivity 3000 Universal Field I/O Software
< 30mV
C-More HMI
100MV @ 500VDC
C-More Micro HMI
switching Mechanical Operating Life 20,000,000 operations
Electrical Operating Life
Control Systems Overview
Minimum 100,000 switching operations with resistive loads
Test Voltage Between Open 750V for 1 minute Contacts 2, indicates output is ON Status Indicators
ViewMarq Industrial Marquees Other HMI Communications Appendix Book 1 Terms and Conditions
Book 1 (14.3)
www.automationdirect.com/fieldIO
Universal Field I/O
eFD-37
Prices as of April 15, 2015. Check Web site for most current prices.
Discrete Combination Terminal PX-549
$98.00
General Specifications
Eight inputs/Eight outputs, 24VDC Discrete Input/Output Terminal The PX-549 (type 1) DC Input/Output Terminal provides eight 24VDC inputs and eight 24VDC 0.5 A outputs with reverse polarity protection and LED status.
Operating Temp Storage Temp Relative Humidity Environment Air Mounting/ Orientation Restrictions Vibration Shock Noise Immunity
Input LED
PX-549
Output LED
1
9 10 11 12 13 14 15 16
2
1 2
3
4
9 10 11 12
3 4 5 6 7 8
5
6
7
13 14 15 16
1
Input 1 Input 2 Input 3
1
2
Input 4 Input 5
2
3
3
Input 6
4
4
5
Input 7 Input 8
5
6
6
7
7
8
8
8
1
9
2
10
3
11
4 5
12 13
6
14
7
15
8
16
Output 1 Output 2
Output 3 Output 4 Output 5 Output 6 Output 7 Output 8
24VDC Power Supply
+ – Connect power supply common (–) to same common as terminal power bus
L L
Protection Class Weight Dimensions (WxHxD) Adjacent Mounting on Bus Terminals with Power Contact Adjacent Mounting on Bus Terminals without Power Contact Passes Terminal Bus Power Passes PE Bus
32 to 131 °F (0 to 55 °C) 13 to 185 °F (-25 to 85 °C) 5% to 95%, non-condensing No corrosive gases permitted 35mm DIN rail/None
Terminal Specifications Inputs/Outputs Per Terminal
8 sinking inputs / 8 sourcing outputs
Data Bytes Used Input/Output Power Source
1 byte (inputs) / 1 byte (outputs) Requires external 24VDC power source
Operating Voltage Rating
24VDC (-15%/+20%)
conforms to EN 60068-2-6 conforms to EN 60068-2-27/ EN 60068-2-29 conforms to EN 61000-6-2/ EN61000-6-4
Current Consumption 25mA typical (from I/O Bus) Current Consumption 15mA + load typical (from Terminal Power Bus)
IP20
Electrical Isolation
60g 12mm x 100mm x 68.8 mm (0.47 in x 3.94 in x 2.71 in) Yes, DC only
500Vms (I/O bus/field potential) 1W max 8 input and 8 output, indicates ON
Heat Dissipation Status Indicators
Input Specifications
Peak Voltage Rating ON Voltage Level OFF Voltage Level No Minimum ON Current Minimum OFF Current Yes Current Consumption (from I/O Bus) No Agency Approvals* UL/cUL File No. E157382, CE OFF to ON Response ON to OFF Response
*To obtain the most current agency approval information,
see the Agency Approval Checklist section on the specific part number’s web page.
30VDC 15 to 30 VDC -3 to +5 VDC 2mA 40mA 3mA typical 3ms 3ms
Output Specifications Max. Load Current per Output On Voltage Drop Maximum Leakage Current
0.5 A (Short-Circuit Protected)
Maximum Inrush Current
2A
0.14 VDC @ 2A 5mA
Maximum Short-Circuit 45V Voltage Resistive, inductive, lamp Load Type Reverse Voltage Protection Yes OFF to ON Response
50ms
ON to OFF Response
75ms
Book 1 (14.3)
eFD-38
Universal Field I/O
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
System Installation and Removal Bus Coupler and Bus Terminal Installation Bus Coupler Installation:
2
1. Attach a Bus Coupler by snapping it onto 35mm DIN rail and securing it into position using the DIN rail locking wheel (where applicable) located on the left side of the coupler.
Insert unit using tongue and groove ntil molded guide and press gently until it becomes firmly seated on DIN rail. ra ail. Where applicable, rotate Locking Wheel to lock Bus Coupler
Bus Terminal Installation: 2. To add a bus terminal, insert unit onto right side of Bus Coupler using the tongue and groove at the top and bottom of the unit, pressing gently until it snaps onto the DIN rail. A proper connection cannot be made by sliding the units together on the DIN rail. When correctly installed, no significant gap can be seen between the attached units. Bus connection is made through the six slide contacts located on the upper right side of the units. Add up to 64 bus terminals per Bus Coupler, including a bus end terminal.
1
Align tab with molded guide
Wiring Connections Wire connection is made through a spring clamp style terminal. This terminal is designed for a single-conductor solid or stranded wire. Wire connection is made by firmly pushing the screwdriver into the screwdriver slot, inserting the wire into the wire slot and removing the screwdriver, locking the wire into position. S Screwdriver Slot S Wire Slot
Removing Bus Coupler and Bus Terminals
Wiring Specifications Connection Type
Spring Clamp Terminals
Wire Gauge/Wire Cross Section*
28-14 AWG / 0.08 - 2.5 mm2
Screwdriver Width
2.5 mm (0.10) such as our TW-SD-MSL-2
Wire Stripping Length
8mm
* For Thermocouple terminals, a thermocouple extension wire is recommended
Where applicable, rotate Locking Wheel to unlock Bus Coupler
A locking mechanism prevents individual units from being pulled off. For bus terminal removal, pull the orange DIN rail release tab firmly to unlatch the unit from the rail. If attached to other terminal units, slide unit forward until released. For Bus Couplers with locking wheels, release the DIN rail locking wheel, then pull firmly on DIN rail release tab.
Firmly pull DIN Rail Release Tab to unlatch unit from rail. Book 1 (14.3)
eFD-24
Universal Field I/O
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
Installation Considerations
Company Information Control Systems Overview
Terminal Dimensions and Spacing Requirements
CLICK PLC
1.4” 35mm min
Use the following diagrams to make sure the Protos X system can be installed in your application. Protos X terminals require 35mm DIN rail for mounting; there are no orientation restrictions.
Do-More PLCs Overview
0.8” 20mm min
Do-More H2 PLC
To ensure proper airflow for cooling purposes, units should be spaced, at a minimum, as shown. It is also important to check the Protos X dimensions against the conditions required for your application.
Do-More T1H PLC
0.8” 20mm min
1.4” 35mm min
DirectLOGIC PLCs Overview DirectLOGIC DL05/06 DirectLOGIC DL105
1.4” 35mm min
DirectLOGIC DL205 DirectLOGIC DL305
1.4” 35mm min
DirectLOGIC DL405 Productivity Controller Overview Productivity 3000
See the Enclosures section for an enclosure that may be suitable for your application
Universal Field I/O Software C-More HMI
PX-TCP2
PX-TCP1 / X MOD PX-MOD
PX PX-903 903
PX-902
Standard Terminal
C-More Micro HMI ViewMarq Industrial Marquees
Ethernet TCP/IP COM
1 2 3 4
ERROR WDG
Us GNDs G
100 mm [3.94”] 4”]
I/I/O /O RUN I/I/O /O ERR
5
1
5
Up
2
6
2
6
GNDp
3
7
3
7
4
8
4
8
TM
DIP
1 2 3 4 5 6 7 8
PE PE
1 2
ON
44 m mm m [1.73”] 3”]
PX-TCP1 PX TCP11
PX-903
24 5 mm 24.5 [.96”] [ 96 96”]]
Terms and Conditions
PX-902 P X-90 02 0 2
27.5 mm [.96”] [.96 ]
12 mm [.47”]
68.8 mm [2.71”]
Book 1 (14.3)
www.automationdirect.com/fieldIO
Communications Appendix Book 1
PE PPEE
.PE
51 mm m [2.01”]]
100 mm [3.94”]
+ +
ON
1 2 3 4 5 6 7 8 9 10 ON
TCP2 PX-TCP2
1
+ +
TM
Other HMI
24V 0V
24VV 00V
Universal Field I/O
eFD-25
TM
Prices as of April 15, 2015. Check Web site for most current prices.
Installation Considerations Terminal Types
8
TYPE 2
Terminal power bus contact Terminal power bus contact
1
5
2
6
3
7
4
8
TYPE 3
I/O Bus contacts
I/O Bus contacts
T Terminal p power bus pass b th h through
Terminal power bus contact
Terminal T power p bus pass b through th h
Terminal power bus contact Terminal PE bus contact
Type 1: This terminal passes the terminal power bus from the preceding terminal to the next terminal and therefore it must be mounted to a preceding terminal that passes bus power.
1
5
2
6
3
7
4
8
Terminal power bus pass through Terminal power bus pass through Terminal PE bus pass through
Type 2: This terminal passes the terminal power bus and PE from the preceding terminal to the next terminal and therefore it must be preceded by a terminal that passes both terminal power bus and PE.
TYPE 4
I/O Bus contacts
I/O B conta
1
5
1
5
2
6
2
6
3
7
4
8
3
7
4
8
Note, bus contacts do not exist on this module
Note, bus and pass through contacts do not exist on this module
Type 3: This terminal does not pass the terminal power bus or PE and can be preceded by any terminal, however it will interrupt the terminal power bus and PE.
Five Basic Terminal Types
PX-970 P PX X-970
TYPE 3
I/O Bus contacts
I/O Bus contacts
Terminal power bus pass through Terminal power bus pass through Terminal PE bus pass through
inal passes the us and PE from the al to the next termiit must be precedhat passes both us and PE.
TYPE 4
1
5
1
5
2
6
2
6
3
7
4
8
3
7
4
8
Note, bus contacts do not exist on this module
Note, bus and pass through contacts do not exist on this module
Type 3: This terminal does not pass the terminal power bus or PE and can be preceded by any terminal, however it will interrupt the terminal power bus and PE.
TYPE 5
I/O Bus contacts
PX-970 P PX X-970
I/O Bus contacts
Terminal power bus supply Terminal power bus supply
Terminal power bus supply
Type 4: This terminal requires external voltage connection and supplies the terminal power bus to terminals located to its right. The terminals to its right must support the same power bus of 120/230 VAC or 24VDC. This terminal will not pass terminal power or PE from any preceding terminals.
Note, bus and pass through contacts do not exist on this module
Type 5: This terminal is used to separate the terminal power bus and PE from other terminals and can mounted next to any terminal.
Book 1 (14.3)
eFD-26
Universal Field I/O
Termi power bus su
Termi power bus su
Termi power bus su
Type 4: This terminal requires exte nal voltage connection and supplie the terminal power bus to terminal located to its right. The terminals t right must support the same powe bus of 120/230 VAC or 24VDC. Th terminal will not pass terminal pow or PE from any preceding terminal
Protos XTM is a trademark of Automationdirect.com Incorporated
5
7
TM
TYPE 1
PE 2
6
Protos X Five Basic Terminal Ty
1-800-633-0405