Preview only show first 10 pages with watermark. For full document please download

Prt-400 Datasheet

   EMBED


Share

Transcript

GigaVUE-420 Data Sheet www.gigamon.com The Smart Route To Visibility™ Gigamon Systems Mgmnt N(b) T(a) IN/OUT IN/OUT T(b) IN/OUT 2 3 4 Giga PORT Product Description Giga TAP-Tx Split Ratio :70/30 GigaTAP-BPC ByPass Tap Giga LI NK - Cu FRONT Giga LI NK - S R Link RDY 1 Giga TAP-Sx Link RDY Console Pwr Link RDY IN OUT INLINE TOOL N(a) IN/OUT Link RDY OUT OUT IN IN IN OUT NETWORK M/S Rdy Giga LI NK - E R BACK GigaVUE-420 CU: modular base unit with a fixed management module containing 4 10/100/1000 Ethernet copper ports, a 10/100/1000 Ethernet management port, and a Cisco compatible serial port. Base unit expandable up to 20GbE ports using 4 optional modules in front, and up to 4 optional 10GbE Ethernet modules in the rear. The front slots accept GigaPORT, GigaTAP-Tx, GigaTAP-BPC and/or GigaTAP-SX/LX/ZX port expansion modules. The rear slots accept 10GbE GigaLINK-XR, 10GbE GigaLINK-CU modules as 10GbE stacking/network/tool ports. All open front and rear expansion slots require blank covers installed to maintain proper system cooling and product warranty. Power: dual redundant hot swappable load-sharing AC or DC power supplies. Cooling: dual redundant hot swappable, field replacable, & GigaLINK-SFP+ cooling fans. GigaVUE-420 FO: similar to GigaVUE-420 CU but with 4 fiber optic GbE ports instead. *See ordering information on page 2. Included Accessories Size and Weight Dimensions Rack mount kit with front and rear rack mounting brackets; Two North American AC modular power cords for AC unit; serial console cable (Cisco compatible). Height: 1.75in Width: 17.31in Depth: 23.50in Power Supplies Two redundant, load sharing, hot-swappable modules (AC or DC). *See Electrical Characteristics below. Weight System: Approx. 30.8lbs Shipping: Approx. 45lbs *Add 2 inches (5.1cm) to depth when 10GigaTAP module is installed. Standard Ports and Expansions Electrical Characteristics Power Supply Types: Dual 1+1 redundant hot swappable power supplies, AC or DC. Heat/Power Dissipation: Fully populated 20+4 port system with all ports at 100% traffic load: nominally 160Watts/546 BTU/hr Voltage: AC power modules: 100 to 240V AC. Fuse rating: internally protected, not user accessible. DC power modules: -36 to -72V DC. Inputs reverse polarity protected. For DC source: optional external fuse rating: 6 Amps Slow-Blo. Current (nominal): 1.45A @ 110V AC 3.33A @ -48V DC Current (surge): 5A @ 110V AC GigaVUE-420 CU base unit: 4 Ethernet 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE802.3ab 1000Base-T Gbps Ethernet). GigaVUE-420 FO base unit: 4Gbps Fiber Optic Ethernet ports (IEEE 802.3z). All base unit include: • (1) 10/100/1000 Base-T RJ45 Ethernet management port • (1) RS-232 console port with RJ45 connector, Cisco compatible. • All Ethernet ports and management port support Auto-MDIX, auto-negotiation. • Front expansion slots: four, each accommodate a single GigaPORT, GigaTAP-Tx, GigaTAP-BPC, GigaTAP-SX/LX/ZX module. • Rear expansion slots: four 10Gbps Ethernet GigaLINK expansion slots, accommodates up to four GigaLINK-CU, GigaLINK-SFP+, or GigaLINK-XR (IEEE 802.3ae) modules, or up to two 10GigaTAP-XR modules. Optional Modules Frequency: 50/60 Hz for AC Mounting Mounts in an EIA-standard 19 inch or 24 inch telco rack or equipment cabinet. Front and rear mounting brackets included. • Four-port GbE modules: GigaPORT, GigaTAP-TX, GigaTAP-SX/LX/ZX, GigaTAP-BPC • Ten-port GbE modules: GigaLINK-CU, GigaLINK-XR, 10GigaTAP-XR. • [NEW] GigaLINK-SFP+ Copyright © 2011 Gigamon, LLC. All rights reserved. Gigamon, GigaVUE, GigaSMART, G-TAP, Flow Mapping, Data Access Network, and Intelligent Data Access Networking are registered trademarks of Gigamon, LLC and/or affiliates in the United States and certain other countries. Citrus, and The Smart Route To Visibility are trademarks of Gigamon. All other trademarks are the property of their respective owners. Gigamon® | 598 Gibraltar Drive Milpitas, CA 95035 | PH 408.263.2022 | www.gigamon.com 1 GigaVUE-420 Data Sheet www.gigamon.com The Smart Route To Visibility™ Safety UL 60950-1; CSA C22.2 EN 60950-1 Emissions FCC Part 15, class A; VCCI class A; EN55022/CISPR-22 class A; Australia/New Zealand AS/NZS CISPR-22 class A; CE Mark EN 55022 class A Order Code Description GVS-421 GigaVUE-420 chassis with four (4) GbE copper ports, dual 1+1 redundant hot swap AC power supplies GVS-422 GigaVUE-420 chassis with four (4) GbE fiber ports, dual 1+1 redundant hot swap AC power supplies GVS-423 Immunity GigaVUE-420 chassis with four (4) GbE copper ports, dual 1+1 redundant hot swap DC power supplies ETSI EN 300 386 V1.3.2, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-3-2 Standards and Protocols Ordering Information IEEE 802.1Q VLAN, IEEE 802.3 10Base-T, IEEE 802.3u 100BaseTX, IEEE 802.3ab 1000Base-T, IEEE 802.3z 1000Base-X, RFC 783 TFTP, RFC 791 IP, RFC 793 TCP, RFC 826 ARP, RFC 854 Telnet, RFC 768 UDP, RFC 792 ICMP, SNMP v1/v2c, RFC 2131 DHCP client, RFC 1492 TACACS+ Management User interface: GUI and/or command line interface CLI; out of band management (serial RS-232C port); telnet, SSH2 through Ethernet management port. RADIUS, TACACS+ support, user group Environment RoHS compliance • All GigaVUE-420 products are RoHS compliant. Operating temperature • 32ºF to 104ºF (0ºC to 40ºC) Operating relative humidity • 20% to 80%, non-condensing GVS-424 GigaVUE-420 chassis with four (4) GbE fiber ports, dual 1+1 redundant hot swap DC power supplies PRT-400 GigaPORT 4-port expansion module SFP-502 SFP, Multimode 850nm SFP-503 SFP, Single Mode 1310nm SFP-504 SFP, Single Mode 1550nm TAP-201 GigaTAP-Tx copper UTP link TAP expansion module TAP-241 GigaTAP-BPC copper in-line bypass TAP expansion module TAP-202 GigaTAP-Sx, multimode, 850nm TAP expansion module TAP-203 GigaTAP-Lx, singlemode, 1310nm TAP expansion module TAP-204 GigaTAP-Zx, singlemode, 1550nm TAP expansion module TAP-GV4-X25B10 10GigaTAP-SR, 10Gbps TAP, multimode, 850nm, LC, 50/50 TAP-GV4-X35C10 10GigaTAP-LR, 10Gbps TAP, singlemode, 1310nm, LC, 50/50 TAP-GV4-X45D10 10GigaTAP-ER, 10Gbps TAP, singlemode, 1550nm, LC, 50/50 GLK-311 GigaLINK-Cu, 10Gigabit copper port module Non-operating/storage temperature GLK-320 GigaLINK-SFP+, empty SFP+ cage, 10 Gig port module • -4ºF to 158ºF (-20ºC to 70ºC) GLK-322 GigaLINK-SR -SFP+, MM 850 10 Gig port module Non-operating/storage relative humidity • 15% to 85%, non-condensing GLK-323 GigaLINK-LR -SFP+, SM 1310 10 Gig port module GLK-324 GigaLINK-ER -SFP+, SM 1550 10 Gig port module GLK-325 GigaLINK-SFP+ LRM, SM 1310 10 Gig port module CBL-005 Stacking Cable, CX4 copper cable, 5 meters CBL-015 Stacking Cable, CX4 copper cable, 15 meters SVC-000 2nd year Standard hardware and software maintenance SVC-001 1st year Premium maintenance upgrade (24x7) SVC-002 2nd year Premium hardware and software maintenance Altitude • Up to 15,000ft. (4.6km) Air flow • Front bottom (cold) to top rear (hot). Performance Port to port throughput: Wire speed per port, no degradation when filters/maps are applied. (24x7) Packet Latency:(typical) 10Gbps to 10Gbps : 3.1 microseconds 1Gbps to 1Gbps : 10.5 microseconds Copyright © 2011 Gigamon, LLC. All rights reserved. Gigamon, GigaVUE, GigaSMART, G-TAP, Flow Mapping, Data Access Network, and Intelligent Data Access Networking are registered trademarks of Gigamon, LLC and/or affiliates in the United States and certain other countries. Citrus, and The Smart Route To Visibility are trademarks of Gigamon. All other trademarks are the property of their respective owners. Gigamon® | 598 Gibraltar Drive Milpitas, CA 95035 | PH 408.263.2022 | www.gigamon.com 2 GigaVUE-420 Data Sheet www.gigamon.com The Smart Route To Visibility™ Front Module Information GigaPORT expansion module GigaTAP-TX dual tap module Front Plug-in Module Specifications GigaTAP-BPC bypass TAP module Giga TAP-Sx UT INLINE TOOL N(a) N(b) T(a) T(b) IN/OUT IN/OUT IN/OUT IN/OUT INO OUT OUT IN IN IN Giga TAP-Tx OUT NETWORK Giga PORT Ports GigaTAP-SX/LX/ZX dual TAP module (MM or SM) SplitR atio :70/30 GigaTAP-BPC ByPass Tap Four, each can be set as Four RJ-45 ports organized Four optical splitter ports. Four RJ-45 ports organized RJ-45 Ethernet (10/100/1000 as two pairs; each pair taps Module taps two GbE MM network pair and in-line Base-T), or GbE SX/LX with a single10/100/1000 Base-T or SM FDX fibers. Split ratio bypass pair; network pair taps multimode or singlemode FDX Ethernet UTP link 70/30 a single10/100/1000 Base-T FDX Ethernet UTP link. In-line SFP module(s) bypass link connects to in-line tool Link Tap Mechanism Not recommended for link Relays open link for tapping Passive optical splitters taps Relays open link for tapping Relays close link for power Power fail does not impact Relays close link for power fail fail link restore link status link restore Maximum two FDX UTP Maximum two FDX fiber inks Maximum one FDX UTP links links tapped per module tapped per module tapped per module and one tapping Power Fail Protection No power fail link restore Total Links Tapped Per Module pair in-line tool links Physical Characteristics Dimensions Weight Optional Accessories 1.50(h) x 3.25(w) x 10.62(d) 1.50(h) x 3.25(w) x 10.62(d) 1.50(h) x 3.25(w) x 10.62(d) 1.50(h) x 3.25(w) x 10.62(d) inches (3.9 x 8.3 x 26.7cm) inches (3.9 x 8.3 x 26.7cm) inches (3.9 x 8.3 x 26.7cm) inches (3.9 x 8.3 x 26.7cm) 1lb. 2oz. (0.55kg) 1lb. 1oz. (0.5kg) 1lb. 9oz. (0.7kg) 1lb. 1oz. (0.5kg) SFP (optical transceiver): -SX 850nm (550m) -LX 1310nm (10km) -ZX 1550nm (40km) *Performance throughput, environment, safety, emissions, immunity, & standards/protocols for modules are the same as the specifications on page 2 Copyright © 2011 Gigamon, LLC. All rights reserved. Gigamon, GigaVUE, GigaSMART, G-TAP, Flow Mapping, Data Access Network, and Intelligent Data Access Networking are registered trademarks of Gigamon, LLC and/or affiliates in the United States and certain other countries. Citrus, and The Smart Route To Visibility are trademarks of Gigamon. All other trademarks are the property of their respective owners. Gigamon® | 598 Gibraltar Drive Milpitas, CA 95035 | PH 408.263.2022 | www.gigamon.com 3 GigaVUE-420 Data Sheet www.gigamon.com The Smart Route To Visibility™ Rear Module Information GigaLINK-SFP+ (10Gigabit optical module) GigaLINK-CU (10Gigabit copper module) 10GigaTAP-SR/LR/ER (10Gigabit optical tap module) Rear 10Gbps Ethernet Plug-in Module Specifications Link RDY LINK OUT GigaLINK -SFP + Connectivity/Distance SFP+ (10GbE optical transceiver) -SR 850nm (300m) PWR OUT IN Optional: stacking cable: A pair of internal passive optical CX4 copper cable splitters (50/50 split ratio) tap a -LR 1310nm (2km standard, -5m (standard) 10km special order) -1 or 10 or 15m -ER 1550 nm (40km standard, LINK IN (special order) 10Gigabit full duplex fiber link Three types of 10GE fiber links supported: 80km special order) -SR 850nm multimode -LR 1310nm singlemode -ER 1550nm singlemode Ports 1 x 10GbE 1 x 10GbE Taps a single Full Duplex 10GbE SFP+ fiber optic port copper CX4 port Fiber Link. Requires two 10Gbps port slots Physical Characteristics Dimensions 1.5(h) x 1.3(w) x 5.0(d) inches 1.5(h) x 1.3(w) x 4.9(d) 1.5(h) x 2.75(w) x 7.3(d) inches (3.8 x 3.3 x 12.7cm) inches (3.8 x 7.0 x 18.2cm) (3.8 x 3.3 x 12.4cm) *Performance throughput, environment, safety, emissions, immunity, & standards/protocols for modules are the same as the specifications on page 2 Copyright © 2011 Gigamon, LLC. All rights reserved. Gigamon, GigaVUE, GigaSMART, G-TAP, Flow Mapping, Data Access Network, and Intelligent Data Access Networking are registered trademarks of Gigamon, LLC and/or affiliates in the United States and certain other countries. Citrus, and The Smart Route To Visibility are trademarks of Gigamon. All other trademarks are the property of their respective owners. Gigamon® | 598 Gibraltar Drive Milpitas, CA 95035 | PH 408.263.2022 | www.gigamon.com 4 GigaVUE-420 Data Sheet www.gigamon.com The Smart Route To Visibility™ Optical Transceiver Specifications (SFP) Description GIGABIT-SX SFP GIGABIT-LX SFP GIGABIT-ZX SFP SFP+ With one 1000Base-SX port; With one 1000Base-LX port; With one 1000Base-ZX port; designed With one 1000Base-ZX port; designed designed for short-distance designed for long-distance for long-distance signal mode 1550nm for long-distance signal mode 1550nm (<550m max.) multimode 850nm singlemode 1310nm fiber fiber connectivity fiber connectivity fiber connectivity connectivity, will support multimode fiber connectivity to limited distances SFP Port One 1000Base-SX port (IEEE One 1000Base-LX port One 1000Base-ZX port (no IEEE 802.3z Type 1000Base-SX, (IEEE 802.3z Type standard exists for 1550nm optics) 850nm multimode) Duplex: full 1000Base-LX, 1310nm Duplex: full Connectors: LC singlemode) Connectors: LC Duplex: full Connectors: LC Physical Characteristics Dimensions: Dimensions: Dimensions: 0.486(h) x 0.54(w) x 2.24(d) 0.486(h) x 0.54(w) x 2.24(d) 0.486(h) x 0.54(w) x 2.24(d) inches inches inches (1.23 x 1.37 x 5.69cm) (1.23 x 1.37 x 5.69cm) (1.23 x 1.37 x 5.69cm) Weight: 0.04lb. (0.02kg) Weight: 0.04lb. (0.02kg) Weight: 0.04lb. (0.02kg) Optical Power & Tx: -9.5 to -3 Rx: -20 to 0 Sensitivity Tx: -9.5 to -3 Tx: 0 to +5 Rx: -19 to 0 Rx sensitivity: -23 to 0 Cabling 62.5/125 μm or 50/125 μm Low metal content, single- Low metal content, singlemode fiber- (core/cladding) diameter, mode fiber-optic, complying optic, complying with ITU-T G.652 and graded-index, low metal content, with ITU-T G.652 and ISO/ ISO/IEC 793-2 Type B1 multimode fiber optic, complying IEC 793-2 Type B1 with ITU-T G.651 and ISO/ IEC 793-2 Type A1b or A1a, Respectively Maximum Distance 220 meters (62.5μm core, 160 10km (singlemode fiber) 80km (singlemode fiber) MHz/km) 275 meters (62.5μm core, 200 MHz/km) 500 meters (50μm core, 400 MHz/km) 550 meters (50μm core, 500 MHz/ km) Copyright © 2011 Gigamon, LLC. All rights reserved. Gigamon, GigaVUE, GigaSMART, G-TAP, Flow Mapping, Data Access Network, and Intelligent Data Access Networking are registered trademarks of Gigamon, LLC and/or affiliates in the United States and certain other countries. Citrus, and The Smart Route To Visibility are trademarks of Gigamon. All other trademarks are the property of their respective owners. Gigamon® | 598 Gibraltar Drive Milpitas, CA 95035 | PH 408.263.2022 | www.gigamon.com 5