Transcript
GigaVUE-420 Data Sheet www.gigamon.com The Smart Route To Visibility™
Gigamon Systems
Mgmnt
N(b)
T(a)
IN/OUT
IN/OUT
T(b) IN/OUT
2
3
4
Giga PORT
Product Description
Giga TAP-Tx
Split Ratio :70/30
GigaTAP-BPC
ByPass Tap
Giga LI NK - Cu
FRONT
Giga LI NK - S R
Link RDY
1
Giga TAP-Sx
Link RDY
Console
Pwr
Link RDY
IN
OUT
INLINE TOOL
N(a) IN/OUT
Link RDY
OUT
OUT
IN
IN
IN
OUT
NETWORK
M/S Rdy
Giga LI NK - E R
BACK
GigaVUE-420 CU: modular base unit with a fixed management module containing 4 10/100/1000 Ethernet copper ports, a 10/100/1000 Ethernet management port, and a Cisco compatible serial port. Base unit expandable up to 20GbE ports using 4 optional modules in front, and up to 4 optional 10GbE Ethernet modules in the rear. The front slots accept GigaPORT, GigaTAP-Tx, GigaTAP-BPC and/or GigaTAP-SX/LX/ZX port expansion modules. The rear slots accept 10GbE GigaLINK-XR, 10GbE GigaLINK-CU modules as 10GbE stacking/network/tool ports. All open front and rear expansion slots require blank covers installed to maintain proper system cooling and product warranty. Power: dual redundant hot swappable load-sharing AC or DC power supplies. Cooling: dual redundant hot swappable, field replacable, & GigaLINK-SFP+ cooling fans. GigaVUE-420 FO: similar to GigaVUE-420 CU but with 4 fiber optic GbE ports instead. *See ordering information on page 2.
Included Accessories
Size and Weight Dimensions
Rack mount kit with front and rear rack mounting brackets; Two North American AC modular power cords for AC unit; serial console cable (Cisco compatible).
Height: 1.75in Width: 17.31in Depth: 23.50in
Power Supplies Two redundant, load sharing, hot-swappable modules (AC or DC). *See Electrical Characteristics below.
Weight System: Approx. 30.8lbs Shipping: Approx. 45lbs
*Add 2 inches (5.1cm) to depth when 10GigaTAP module is installed.
Standard Ports and Expansions
Electrical Characteristics Power Supply Types:
Dual 1+1 redundant hot swappable power supplies, AC or DC.
Heat/Power Dissipation: Fully populated 20+4 port system with all ports at 100% traffic load: nominally 160Watts/546 BTU/hr
Voltage: AC power modules: 100 to 240V AC. Fuse rating: internally protected, not user accessible. DC power modules: -36 to -72V DC. Inputs reverse polarity protected. For DC source: optional external fuse rating: 6 Amps Slow-Blo.
Current (nominal): 1.45A @ 110V AC 3.33A @ -48V DC Current (surge): 5A @ 110V AC
GigaVUE-420 CU base unit: 4 Ethernet 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE802.3ab 1000Base-T Gbps Ethernet). GigaVUE-420 FO base unit: 4Gbps Fiber Optic Ethernet ports (IEEE 802.3z). All base unit include:
• (1) 10/100/1000 Base-T RJ45 Ethernet management port • (1) RS-232 console port with RJ45 connector, Cisco compatible. • All Ethernet ports and management port support Auto-MDIX, auto-negotiation. • Front expansion slots: four, each accommodate a single GigaPORT, GigaTAP-Tx, GigaTAP-BPC, GigaTAP-SX/LX/ZX module. • Rear expansion slots: four 10Gbps Ethernet GigaLINK expansion slots, accommodates up to four GigaLINK-CU, GigaLINK-SFP+, or GigaLINK-XR (IEEE 802.3ae) modules, or up to two 10GigaTAP-XR modules.
Optional Modules
Frequency: 50/60 Hz for AC
Mounting Mounts in an EIA-standard 19 inch or 24 inch telco rack or equipment cabinet. Front and rear mounting brackets included.
• Four-port GbE modules: GigaPORT, GigaTAP-TX, GigaTAP-SX/LX/ZX, GigaTAP-BPC • Ten-port GbE modules: GigaLINK-CU, GigaLINK-XR, 10GigaTAP-XR. • [NEW] GigaLINK-SFP+
Copyright © 2011 Gigamon, LLC. All rights reserved. Gigamon, GigaVUE, GigaSMART, G-TAP, Flow Mapping, Data Access Network, and Intelligent Data Access Networking are registered trademarks of Gigamon, LLC and/or affiliates in the United States and certain other countries. Citrus, and The Smart Route To Visibility are trademarks of Gigamon. All other trademarks are the property of their respective owners.
Gigamon® | 598 Gibraltar Drive Milpitas, CA 95035 | PH 408.263.2022 | www.gigamon.com
1
GigaVUE-420 Data Sheet www.gigamon.com The Smart Route To Visibility™
Safety
UL 60950-1; CSA C22.2 EN 60950-1
Emissions
FCC Part 15, class A; VCCI class A; EN55022/CISPR-22 class A; Australia/New Zealand AS/NZS CISPR-22 class A; CE Mark EN 55022 class A
Order Code
Description
GVS-421
GigaVUE-420 chassis with four (4) GbE copper ports, dual 1+1 redundant hot swap AC power supplies
GVS-422
GigaVUE-420 chassis with four (4) GbE fiber ports, dual 1+1 redundant hot swap AC power supplies
GVS-423
Immunity
GigaVUE-420 chassis with four (4) GbE copper ports, dual 1+1 redundant hot swap DC power supplies
ETSI EN 300 386 V1.3.2, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-3-2
Standards and Protocols
Ordering Information
IEEE 802.1Q VLAN, IEEE 802.3 10Base-T, IEEE 802.3u 100BaseTX, IEEE 802.3ab 1000Base-T, IEEE 802.3z 1000Base-X, RFC 783 TFTP, RFC 791 IP, RFC 793 TCP, RFC 826 ARP, RFC 854 Telnet, RFC 768 UDP, RFC 792 ICMP, SNMP v1/v2c, RFC 2131 DHCP client, RFC 1492 TACACS+
Management
User interface: GUI and/or command line interface CLI; out of band management (serial RS-232C port); telnet, SSH2 through Ethernet management port. RADIUS, TACACS+ support, user group
Environment RoHS compliance
• All GigaVUE-420 products are RoHS compliant. Operating temperature • 32ºF to 104ºF (0ºC to 40ºC) Operating relative humidity • 20% to 80%, non-condensing
GVS-424
GigaVUE-420 chassis with four (4) GbE fiber ports, dual 1+1 redundant hot swap DC power supplies
PRT-400
GigaPORT 4-port expansion module
SFP-502
SFP, Multimode 850nm
SFP-503
SFP, Single Mode 1310nm
SFP-504
SFP, Single Mode 1550nm
TAP-201
GigaTAP-Tx copper UTP link TAP expansion module
TAP-241
GigaTAP-BPC copper in-line bypass TAP expansion module
TAP-202
GigaTAP-Sx, multimode, 850nm TAP expansion module
TAP-203
GigaTAP-Lx, singlemode, 1310nm TAP expansion module
TAP-204
GigaTAP-Zx, singlemode, 1550nm TAP expansion module
TAP-GV4-X25B10
10GigaTAP-SR, 10Gbps TAP, multimode, 850nm, LC, 50/50
TAP-GV4-X35C10
10GigaTAP-LR, 10Gbps TAP, singlemode, 1310nm, LC, 50/50
TAP-GV4-X45D10
10GigaTAP-ER, 10Gbps TAP, singlemode, 1550nm, LC, 50/50
GLK-311
GigaLINK-Cu, 10Gigabit copper port module
Non-operating/storage temperature
GLK-320
GigaLINK-SFP+, empty SFP+ cage, 10 Gig port module
• -4ºF to 158ºF (-20ºC to 70ºC)
GLK-322
GigaLINK-SR -SFP+, MM 850 10 Gig port module
Non-operating/storage relative humidity • 15% to 85%, non-condensing
GLK-323
GigaLINK-LR -SFP+, SM 1310 10 Gig port module
GLK-324
GigaLINK-ER -SFP+, SM 1550 10 Gig port module
GLK-325
GigaLINK-SFP+ LRM, SM 1310 10 Gig port module
CBL-005
Stacking Cable, CX4 copper cable, 5 meters
CBL-015
Stacking Cable, CX4 copper cable, 15 meters
SVC-000
2nd year Standard hardware and software maintenance
SVC-001
1st year Premium maintenance upgrade (24x7)
SVC-002
2nd year Premium hardware and software maintenance
Altitude • Up to 15,000ft. (4.6km) Air flow • Front bottom (cold) to top rear (hot).
Performance Port to port throughput: Wire speed per port, no degradation when filters/maps are applied.
(24x7)
Packet Latency:(typical) 10Gbps to 10Gbps : 3.1 microseconds 1Gbps to 1Gbps : 10.5 microseconds Copyright © 2011 Gigamon, LLC. All rights reserved. Gigamon, GigaVUE, GigaSMART, G-TAP, Flow Mapping, Data Access Network, and Intelligent Data Access Networking are registered trademarks of Gigamon, LLC and/or affiliates in the United States and certain other countries. Citrus, and The Smart Route To Visibility are trademarks of Gigamon. All other trademarks are the property of their respective owners.
Gigamon® | 598 Gibraltar Drive Milpitas, CA 95035 | PH 408.263.2022 | www.gigamon.com
2
GigaVUE-420 Data Sheet www.gigamon.com The Smart Route To Visibility™
Front Module Information GigaPORT expansion module
GigaTAP-TX dual tap module
Front Plug-in Module Specifications
GigaTAP-BPC bypass TAP module
Giga TAP-Sx
UT
INLINE TOOL
N(a)
N(b)
T(a)
T(b)
IN/OUT
IN/OUT
IN/OUT
IN/OUT
INO
OUT
OUT
IN
IN
IN
Giga TAP-Tx
OUT
NETWORK
Giga PORT
Ports
GigaTAP-SX/LX/ZX dual TAP module (MM or SM)
SplitR atio :70/30
GigaTAP-BPC
ByPass Tap
Four, each can be set as
Four RJ-45 ports organized
Four optical splitter ports.
Four RJ-45 ports organized
RJ-45 Ethernet (10/100/1000
as two pairs; each pair taps
Module taps two GbE MM
network pair and in-line
Base-T), or GbE SX/LX with
a single10/100/1000 Base-T
or SM FDX fibers. Split ratio
bypass pair; network pair taps
multimode or singlemode
FDX Ethernet UTP link
70/30
a single10/100/1000 Base-T FDX Ethernet UTP link. In-line
SFP module(s)
bypass link connects to in-line tool
Link Tap Mechanism
Not recommended for link
Relays open link for tapping
Passive optical splitters taps
Relays open link for tapping
Relays close link for power
Power fail does not impact
Relays close link for power fail
fail link restore
link status
link restore
Maximum two FDX UTP
Maximum two FDX fiber inks
Maximum one FDX UTP links
links tapped per module
tapped per module
tapped per module and one
tapping
Power Fail Protection
No power fail link restore
Total Links Tapped Per Module
pair in-line tool links
Physical Characteristics Dimensions Weight Optional Accessories
1.50(h) x 3.25(w) x 10.62(d)
1.50(h) x 3.25(w) x 10.62(d)
1.50(h) x 3.25(w) x 10.62(d)
1.50(h) x 3.25(w) x 10.62(d)
inches (3.9 x 8.3 x 26.7cm)
inches (3.9 x 8.3 x 26.7cm)
inches (3.9 x 8.3 x 26.7cm)
inches (3.9 x 8.3 x 26.7cm)
1lb. 2oz. (0.55kg)
1lb. 1oz. (0.5kg)
1lb. 9oz. (0.7kg)
1lb. 1oz. (0.5kg)
SFP (optical transceiver): -SX 850nm (550m) -LX 1310nm (10km) -ZX 1550nm (40km)
*Performance throughput, environment, safety, emissions, immunity, & standards/protocols for modules are the same as the specifications on page 2
Copyright © 2011 Gigamon, LLC. All rights reserved. Gigamon, GigaVUE, GigaSMART, G-TAP, Flow Mapping, Data Access Network, and Intelligent Data Access Networking are registered trademarks of Gigamon, LLC and/or affiliates in the United States and certain other countries. Citrus, and The Smart Route To Visibility are trademarks of Gigamon. All other trademarks are the property of their respective owners.
Gigamon® | 598 Gibraltar Drive Milpitas, CA 95035 | PH 408.263.2022 | www.gigamon.com
3
GigaVUE-420 Data Sheet www.gigamon.com The Smart Route To Visibility™
Rear Module Information GigaLINK-SFP+ (10Gigabit optical module)
GigaLINK-CU (10Gigabit copper module)
10GigaTAP-SR/LR/ER (10Gigabit optical tap module)
Rear 10Gbps Ethernet Plug-in Module Specifications Link RDY
LINK
OUT
GigaLINK -SFP +
Connectivity/Distance
SFP+ (10GbE optical transceiver) -SR 850nm (300m)
PWR
OUT IN
Optional: stacking cable:
A pair of internal passive optical
CX4 copper cable
splitters (50/50 split ratio) tap a
-LR 1310nm (2km standard,
-5m (standard)
10km special order)
-1 or 10 or 15m
-ER 1550 nm (40km standard,
LINK IN
(special order)
10Gigabit full duplex fiber link Three types of 10GE fiber links supported:
80km special order)
-SR 850nm multimode -LR 1310nm singlemode -ER 1550nm singlemode
Ports
1 x 10GbE
1 x 10GbE
Taps a single Full Duplex 10GbE
SFP+ fiber optic port
copper CX4 port
Fiber Link. Requires two 10Gbps port slots
Physical Characteristics Dimensions
1.5(h) x 1.3(w) x 5.0(d) inches
1.5(h) x 1.3(w) x 4.9(d)
1.5(h) x 2.75(w) x 7.3(d) inches
(3.8 x 3.3 x 12.7cm)
inches
(3.8 x 7.0 x 18.2cm)
(3.8 x 3.3 x 12.4cm)
*Performance throughput, environment, safety, emissions, immunity, & standards/protocols for modules are the same as the specifications on page 2
Copyright © 2011 Gigamon, LLC. All rights reserved. Gigamon, GigaVUE, GigaSMART, G-TAP, Flow Mapping, Data Access Network, and Intelligent Data Access Networking are registered trademarks of Gigamon, LLC and/or affiliates in the United States and certain other countries. Citrus, and The Smart Route To Visibility are trademarks of Gigamon. All other trademarks are the property of their respective owners.
Gigamon® | 598 Gibraltar Drive Milpitas, CA 95035 | PH 408.263.2022 | www.gigamon.com
4
GigaVUE-420 Data Sheet www.gigamon.com The Smart Route To Visibility™
Optical Transceiver Specifications (SFP)
Description
GIGABIT-SX SFP
GIGABIT-LX SFP
GIGABIT-ZX SFP
SFP+
With one 1000Base-SX port;
With one 1000Base-LX port;
With one 1000Base-ZX port; designed
With one 1000Base-ZX port; designed
designed for short-distance
designed for long-distance
for long-distance signal mode 1550nm
for long-distance signal mode 1550nm
(<550m max.) multimode 850nm
singlemode 1310nm fiber
fiber connectivity
fiber connectivity
fiber connectivity
connectivity, will support multimode fiber connectivity to limited distances
SFP Port
One 1000Base-SX port (IEEE
One 1000Base-LX port
One 1000Base-ZX port (no IEEE
802.3z Type 1000Base-SX,
(IEEE 802.3z Type
standard exists for 1550nm optics)
850nm multimode) Duplex: full
1000Base-LX, 1310nm
Duplex: full
Connectors: LC
singlemode)
Connectors: LC
Duplex: full Connectors: LC
Physical Characteristics
Dimensions:
Dimensions:
Dimensions:
0.486(h) x 0.54(w) x 2.24(d)
0.486(h) x 0.54(w) x 2.24(d)
0.486(h) x 0.54(w) x 2.24(d) inches
inches
inches
(1.23 x 1.37 x 5.69cm)
(1.23 x 1.37 x 5.69cm)
(1.23 x 1.37 x 5.69cm)
Weight: 0.04lb. (0.02kg)
Weight: 0.04lb. (0.02kg)
Weight: 0.04lb. (0.02kg)
Optical Power & Tx: -9.5 to -3 Rx: -20 to 0 Sensitivity
Tx: -9.5 to -3
Tx: 0 to +5
Rx: -19 to 0
Rx sensitivity: -23 to 0
Cabling
62.5/125 μm or 50/125 μm
Low metal content, single-
Low metal content, singlemode fiber-
(core/cladding) diameter,
mode fiber-optic, complying
optic, complying with ITU-T G.652 and
graded-index, low metal content,
with ITU-T G.652 and ISO/
ISO/IEC 793-2 Type B1
multimode fiber optic, complying
IEC 793-2 Type B1
with ITU-T G.651 and ISO/ IEC 793-2 Type A1b or A1a, Respectively
Maximum Distance
220 meters (62.5μm core, 160
10km (singlemode fiber)
80km (singlemode fiber)
MHz/km) 275 meters (62.5μm core, 200 MHz/km) 500 meters (50μm core, 400 MHz/km) 550 meters (50μm core, 500 MHz/ km)
Copyright © 2011 Gigamon, LLC. All rights reserved. Gigamon, GigaVUE, GigaSMART, G-TAP, Flow Mapping, Data Access Network, and Intelligent Data Access Networking are registered trademarks of Gigamon, LLC and/or affiliates in the United States and certain other countries. Citrus, and The Smart Route To Visibility are trademarks of Gigamon. All other trademarks are the property of their respective owners.
Gigamon® | 598 Gibraltar Drive Milpitas, CA 95035 | PH 408.263.2022 | www.gigamon.com
5