PS-RM-48V Rack Mount Power Supply 48V 1¾" 19" AC IN D C D C O U T O U T CAUTION AC INPUT 115/230VAC 50/60 HZ RISK OF ELECTRIC SHOCK UNIT TO BE SERVICED BY QUALIFIED PERSONN EL ONLY Description: The 48V Rack Mount Power Supply PS-RM-48V is designed to provide power to Telemetrics robotics systems. It produces enough power to operate multiple 48V Pan/Tilt heads, auxiliary robotics devices such as trolley, televator, teleglide, etc., cameras, large teleprompters and confidence monitors. The power supply is available as a basic single and optional dual configuration to satisfy specific customer requirements. The single model has one DC output, which can deliver 250 W of power. The dual model has 2 DC outputs, each one capable of providing 250 W of power. If only one output on the dual model is used, it can deliver up to 500 W of power at this output. If only one output is used and the power consumption does not exceed 250 W, the dual model will operate as a fully redundant power supply. Specifications Features:     Power factor correction. 250W Output Power (single). 2 X 250W or 1 X 500W Output Power (dual). Redundancy (250W, dual).    Active Current Sharing (dual). Over-current, over-voltage and thermal protection AC, DC and FAN monitoring. Specifications Maximum Cable Distances      1500 feet 900 feet 500 feet 300 feet* 200 feet* P/T P/T + Camera (40 W) P/T + Televator + Camera (40 W) P/T + Televator + Camera (40 W) + Teleprompter (80 W) P/T + Televator + Camera (40 W) + Teleprompter (80 W) + Confidence Monitor (40 W) Specifications Specifications: OUTPUT: Voltage: INPUT: Voltage: Frequency: Current: 48 V DC (adjusted to 50 V DC typical) Current: 5 A (single) 2 x 5 A or 10 A (dual) Power: 250 W (single) 2 x 250 W or 500 W (dual) Total Regulation: ± 2% max (line and load) Turn-on delay: 2.0 s max Temperature Coefficient: ± 0.02%/°C Overvoltage Protection: 115 ± 5% Short Circuit Protection: Continuous Connector: XLR-7 F, female 85 - 264 V AC 47 - 63 Hz 2.8 A max at 115 V AC (single) 1.4 A max at 230 V AC (single) 5.6 A max at 115 V AC (dual) 2.8 A max at 230 V AC (dual) Inrush Current: 40 A max at 264 V AC (single) 80 A max at 264 V AC (dual) Power Inlet: IEC 60320/C14 *Use with dual PS to 1 P/T head. MECHANICAL: Dimensions: 19.0”W x 1.75”H x 11.5”D (10.5” behind rack) (48.3 x 4.4 x 29.2 cm) Weight: 7.0 lbs (3.2 kg) ENVIRONMENTAL: Operating Temperature: 0°C to 40°C Storage Temperature: -40°C to 85°C Humidity: 5% to 95% RH, non-condensing Models: Description Model Number Rack Mount Single Power Supply Rack Mount Dual Power Supply Option PS-RM-48V-1 PSO-RM-48V-2 10/07 printed in U.S.A. Eng # 55927 Specifications and features subject to change without notice. 6 Leighton Place Mahwah, New Jersey, U.S.A. 07430 Phone: (201)848-9818 Fax: (201)848-9819 www.telemetricsinc.com PS-RM-48V Rack Mount Power Supply 48V Basic Connection Diagrams Teleprompter CA-PWR-7XLR* * For max cable length refer to Table 1-A or Table 1-B LP Pan/Tilt PT-LP-S3-48 TALLY PROM PT CC1 EXT/CC LENS CAME RA VID EO G ENLOCK VIDEO PRO MPT GENLOC K SERI AL ETHERN ET PO WER AUX Rack Mount Power Supply 48V PS-RM-48V-1 (Table 1-A) or PS-RM-48V-1 + PSO-RM-48V-2 (Table 1-B) Elevating Pedestal EP-PT-S2 Figure 1 CA-PWR-7XLR* * For max cable length refer to Table 1-A Teleprompter Teleprompter LP Pan/Tilt PT-LP-S3-48 TALLY PROMPT CC 1 EXT/ CC LENS C AMERA VI DEO CA-PWR-7XLR* LP Pan/Tilt PT-LP-S3-48 TALLY PROMPT CC 1 EXT/ CC LENS CAMERA VI DEO GENLOC K GENLO CK VI DEO PROMP T SERIAL ETHERNET POW ER VI DEO SERIAL ETHERNET POW ER PROM PT G ENLOCK AUX G ENLOCK AUX * For max cable length refer to Table 1-A Elevating Pedestal EP-PT-S2 Elevating Pedestal EP-PT-S2 Rack Mount Power Supply 48V PS-RM-48V-1 + PSO-RM-48V-2 (Table 1-A) Figure 2 LP Pan/Tilt PT-LP-S3-48 CA-PWR-7XLR (100 feet max) CA-PWR-7XLR (100 feet max) CA-PWR-7XLR* CA-PWR-7XLR (100 feet max) * For max cable length refer to Table 1-A or Table 1-C A LY T PROM PT CC1 LP Pan/Tilt PT-LP-S3-48 EX T/CC LENS CAMERA VIDEO GEN O L CK VIDEO SERIA L ETHERNET POW ER PROM PT GENLOCK LP Pan/Tilt PT-LP-S3-48 AUX TALLY PROMPT CC 1 EXT/ CC 48V Power Adapter PS-PA-48V Rack Mount Power Supply 48V PS-RM-48V-1 (Table 1-A) or PS-RM-48V-1 + PSO-RM-48V-2 (Table 1-C) LENS CAMERA VI DEO GENLO CK VI DEO PROM PT G ENLOCK SERIAL ETHERNET POW ER AUX TALLY PROM PT CC1 EXT/CC LENS CAMER A VIDE O G ENLOCK VIDEO PRO MPT GENLOC K SERI AL ETHERN ET PO WER AUX Figure 3 CA-PWR-7XLR* * For max cable length refer to Table 1-A or Table 1-B CA-PWR-CMTR (50 feet max) CA-PWR-CMTR (50 feet max) CA-PWR-CMTR (50 feet max) Compact Pan/Tilt PT-CP-S2** Rack Mount Power Supply 48V PS-RM-48V-1 (Table 1-A) or PS-RM-48V-1 + PSO-RM-48V-2 (Table 1-B) 48V Power Converter PS-PC-24/12V Compact Pan/Tilt PT-CP-S2** Figure 4 Compact Pan/Tilt PT-CP-S2** Specifications and features subject to change without notice. 6 Leighton Place Mahwah, New Jersey, U.S.A. 07430 Phone: (201)848-9818 Fax: (201)848-9819 www.telemetricsinc.com ** Applicable also to PT-HP-S2. PS-RM-48V Rack Mount Power Supply 48V Power Cable Distance Capability Power cables are used to deliver power from the power supply to the P/T heads in three different ways: 1) Using direct connections - i.e. connecting each power supply output to a 48V P/T head as illustrated in Figures 1 and 2. The maximum length for each cable can be determined from Table 1, column A, based on the total power consumption of the P/T head and all other devices, attached to it such as televator, camera, lens, viewfinder, teleprompter, etc. For distances 400 feet and shorter, more power can be delivered by using a dual power supply to power a single 48V P/T head. To determine the maximum cable length in this case, please refer to Table 1, column B. 2) Using 48V Power Adapter PS-PA-48V as shown in Figure 3. This configuration allows up to three 48V P/T heads to be powered from one power supply unit. The maximum length of the cable from the power supply to the power adapter can be determined from Table 1, column A (for single power supply) or Table 1, column C (for dual power supply), based on the total power at the input of the breakout box. To calculate that power, add the maximum power consumption of all P/T heads, cameras, etc. and multiply the result by 1.1. 3) Using 48V Power Converter PS-PC-24/12V as shown in Figure 4. This configuration allows up to three 24V P/T heads to be powered from one power supply unit. The power converter converts 48V down to 24V and 12V for the P/T heads and the cameras respectively. The maximum length of the cable from the power supply to the power converter can be determined from Table 1, column A (for single power supply) or Table 1, column B (for dual power supply), based on the total power at the input of the converter. To calculate that power, add the maximum power consumption of all P/T heads, cameras, etc. and multiply the result by 1.2. Table 1 Cable Model Number CA-PWR-7XLR-6 CA-PWR-7XLR-10 CA-PWR-7XLR-25 CA-PWR-7XLR-50 CA-PWR-7XLR-75 CA-PWR-7XLR-100 CA-PWR-7XLR-125 CA-PWR-7XLR-150 CA-PWR-7XLR-200 CA-PWR-7XLR-250 CA-PWR-7XLR-300 CA-PWR-7XLR-400 CA-PWR-7XLR-500 CA-PWR-7XLR-600 CA-PWR-7XLR-700 CA-PWR-7XLR-800 CA-PWR-7XLR-900 CA-PWR-7XLR-1000 CA-PWR-7XLR-1250 CA-PWR-7XLR-1500 Max. Delivered Power (W) A B C 225 290 447 224 290 446 222 290 440 220 290 430 218 290 420 215 290 411 213 290 401 210 290 391 205 290 372 201 280 333 196 260 277 186 208 208 166 166 166 138 138 138 118 118 118 104 104 104 92 92 92 83 83 83 66 66 66 55 55 55 P/T Head EP-PT-S2 Televator EPT Telepod ECM-PT-S2 External Camera Mount EWM-PT-S2 Elevating Wall Mount CTS-S2 Servo Trolley TG-TRO1 Compact Teleglide TG-XXX Teleglide (other models) 1. Calculate total power consumption: For Figure 1 and 2: PTOTAL = PP/T + PTELEVATOR + PCAM + PLENS + PVF + PPROMPT + … For Figure 3: PTOTAL = (PP/T1 + PCAM1 + PP/T2 + PCAM2 + PP/T3 + P CAM3 + ...)x1.1 For Figure 4: PTOTAL = (PP/T1 + PCAM1 + PP/T2 + PCAM2 + PP/T3 + P CAM3 + ...)x1.2 2. In Table 1 find a cable with PDELIVERED MAX > PTOTAL Use column A for:   Single power supply (all configurations) Dual power supply to two P/T heads (Figure 2). Use column B for:   Dual power supply to one P/T head (Figure 1) Dual power supply to 48V Power Converter (Figure 4). Use column C for: Table 2 Telemetrics Robotic Device To determine maximum cable length  Typical Power Consumption 50 W 75 W 50 W 100 W 75 W 35 W 50 W consult factory Dual power supply to 48V Power Adapter (Figure 3). Note: For distances 500 feet or longer use only column A (Single power supply or dual power supply to two P/T heads). Specifications and features subject to change without notice. 6 Leighton Place Mahwah, New Jersey, U.S.A. 07430 Phone: (201)848-9818 Fax: (201)848-9819 www.telemetricsinc.com