Preview only show first 10 pages with watermark. For full document please download

Psa- … Power Supply Systems

   EMBED


Share

Transcript

PSA- … Power Supply Systems Controller 1 PCA 02 3 RU Sub-rack 6 RU Sub-rack Rectifiers: 23 GR 60 or 25 GR 48 Max. output at 230 VAC 3 RU: max. 75 A / 48 VDC or 69 A / 60VDC 6 RU: max. 150 A / 48 VDC or 138 A / 60VDC Max. output at 120 VAC: 3 RU: max. 37.5 A / 48 VDC or 34.5 A / 60 VDC 6 RU: max. 75 A / 48 VDC or 69 A / 60 VDC (depending on type of rectifier) (depending on type of rectifier) (depending on type of rectifier) (depending on type of rectifier) The INDUSTRONIC PSA systems are complete power supply systems ready to use. Based on the latest technology they are modularly designed and are thus highly flexible and adaptable to all requirements. Made up of a sub-rack comprising a controller and one to three rectifiers, with the option of an additional sub-rack with up to three more rectifiers, they are available in all sizes and capacities for both 60 VDC and 48 VDC. Due to the excellent emergency operating features of the individual rectifiers the risk of complete failure of the power supply system is absolutely minimized. The hot-plug-in design allows for easy substitution of rectifiers during operation. The controller used to control the rectifiers offers a multitude of monitoring functions. These can be effectively handled via the integrated display and keys of the controller. Doc. no. DAT-309-799-100 • Rev. 7 • EN • 10.10.2011 © INDUSTRONIC Subject to technical modifications 1/4 Block diagram 23 GR 60 or 25 GR 48 X300 X200 X100 23 GR 60 or 25 GR 48 X301 X201 23 GR 60 or 25 GR 48 X101 X302 X202 X102 1 PCA 02 USB X2 Controller X306:10 X304:10 L- RS 232 X305:10 X306:2 X304:2 L+ L+ X220: L X220: N X221: L X221: N X305:2 X222: L X222: N PE PE Backplane PE bolt X1 X1 Connection card X9 X1 X7 X8 L L L N N N X7:1,2,3: Fault power supply || X7:4,5,6: Mains failure X8:1,2: Battery voltage X8:5,6: Activation deep discharge relay (optional) X9 (RJ45): For measuring extension X10 (RJ45): System-bus for power supply extension X4 Measuring extension for measurements (temperature, battery balance, load voltage) and separate fault monitoring (potential-free contacts) K7 Doc. no. DAT-309-799-100 • Rev. 7 • EN • 10.10.2011 © INDUSTRONIC X2: K8 K9 K10 29,30 Further monitoring K6 Further monitoring Further monitoring K5 Further monitoring 7,8 Further monitoring 1,2,3 Further monitoring K4 Battery unbalance failure K3 Battery Temperature indication output Common failure K2 Mains failure X1: K1 Further monitoring RJ45 L- Subject to technical modifications 2/4 Construction Components Mechanical data  1 control unit 1 PCA 02 (Art. no. 008-302-010)  1 to 2 racks (Art. no. 031-001-180)  1 to 6 rectifiers: 23 GR 60 (Art. no. 008-201-056) 25 GR 48 (Art. no. 008-201-057)  Optional: measuring extension (Art. no. 309-799-125)  Optional: Unbalance set (Art. no. 309-799-126)  Height x Width x depth 3/6 RU, 19", 310 mm (12 1/4")  Connection 1 ph, optional 3 ph  IU characteristics acc. to DIN 41772/41773  DC current and voltage display  Voltage monitoring (battery, load, overvoltage/undervoltage)  Battery deep discharge (optional)  Common failure indication output  Mains failure  Temperature compensation of battery voltage  Battery balance monitoring (optional)  Battery availability test - total battery (optional)  Battery discharge protection control (optional)  Common failure indication output  Mains failure  Rectifier failure  Battery unbalance (optional)  Load voltage error (optional)  Temperature failure (optional)  Battery failure (optional) Functions Control and monitoring functions Failure monitoring Additional measuring extension (Art. no. 309-799-125) Additional control and monitoring functions Additional failure monitoring Doc. no. DAT-309-799-100 • Rev. 7 • EN • 10.10.2011 © INDUSTRONIC Subject to technical modifications 3/4 Systems Type Input (nom.) Output (nom.) RU Controller Rectifier Sub-rack 230 VAC input / 60 VDC output PSA- 230/60/23 230 VAC / 8 A 60 VDC / 23 A 3 1 x 1 PCA 02 1 x 23 GR 60 1 PSA- 230/60/46 230 VAC / 16 A 60 VDC / 46 A 3 1 x 1 PCA 02 2 x 23 GR 60 1 PSA- 230/60/69 230 VAC / 24 A 60 VDC / 69 A 3 1 x 1 PCA 02 3 x 23 GR 60 1 PSA- 230/60/92 230 VAC / 32 A 60 VDC / 92 A 6 1 x 1 PCA 02 4 x 23 GR 60 2 PSA- 230/60/115 230 VAC / 40 A 60 VDC / 115 A 6 1 x 1 PCA 02 5 x 23 GR 60 2 PSA- 230/60/138 230 VAC / 48 A 60 VDC / 138 A 6 1 x 1 PCA 02 6 x 23 GR 60 2 120 VAC input / 60 VDC output PSA- 120/60/11 120 VAC / 8 A 60 VDC / 11.5 A 3 1 x 1 PCA 02 1 x 23 GR 60 1 PSA- 120/60/23 120 VAC / 16 A 60 VDC / 23 A 3 1 x1 PCA 02 2 x 23 GR 60 1 PSA- 120/60/35 120 VAC / 24 A 60 VDC / 34.5 A 3 1 x 1 PCA 02 3 x 23 GR 60 1 PSA- 120/60/46 120 VAC / 32 A 60 VDC / 46 A 6 1 x 1 PCA 02 4 x 23 GR 60 2 PSA- 120/60/58 120 VAC / 40 A 60 VDC / 57.5 A 6 1 x 1 PCA 02 5 x 23 GR 60 2 PSA- 120/60/69 120 VAC / 48 A 60 VDC / 69 A 6 1 x 1 PCA 02 6 x 23 GR 60 2 230 VAC input / 48 VDC output PSA- 230/48/25 230 VAC / 8 A 48 VDC / 25 A 3 1 x 1 PCA 02 1 x 25 GR 48 1 PSA- 230/48/50 230 VAC / 16 A 48 VDC / 50 A 3 1 x 1 PCA 02 2 x 25 GR 48 1 PSA- 230/48/75 230 VAC / 24 A 48 VDC / 75 A 3 1 x 1 PCA 02 3 x 25 GR 48 1 PSA- 230/48/100 230 VAC / 32 A 48 VDC / 100 A 6 1 x 1 PCA 02 4 x 25 GR 48 2 PSA- 230/48/125 230 VAC / 40 A 48 VDC / 125 A 6 1 x 1 PCA 02 5 x 25 GR 48 2 PSA- 230/48/150 230 VAC / 48 A 48 VDC / 150 A 6 1 x 1 PCA 02 6 x 25 GR 48 2 120 VAC input / 48 VDC output PSA- 120/48/12 120 VAC / 8 A 48 VDC / 12.5 A 3 1 x 1 PCA 02 1 x 25 GR 48 1 PSA- 120/48/25 120 VAC / 16 A 48 VDC / 25 A 3 1 x 1 PCA 02 2 x 25 GR 48 1 PSA- 120/48/37 120 VAC / 24 A 48 VDC / 37.5 A 3 1 x 1 PCA 02 3 x 25 GR 48 1 PSA- 120/48/50 120 VAC / 32 A 48 VDC / 50 A 6 1 x 1 PCA 02 4 x 25 GR 48 2 PSA- 120/48/62 120 VAC / 40 A 48 VDC / 62.5 A 6 1 x 1 PCA 02 5 x 25 GR 48 2 PSA- 120/48/75 120 VAC / 48 A 48 VDC / 75 A 6 1 x 1 PCA 02 6 x 25 GR 48 2 ® INDUSTRONIC Industrie-Electronic GmbH & Co. KG Carl-Jacob-Kolb-Weg 1 97877 Wertheim / Germany Tel.: +49 9342 871-0 Fax: +49 9342 871-565 [email protected] www.industronic.com Doc. no. DAT-309-799-100 • Rev. 7 • EN • 10.10.2011 © INDUSTRONIC Subject to technical modifications 4/4