Preview only show first 10 pages with watermark. For full document please download

Psc-60 Series

   EMBED


Share

Transcript

MEAN WELL 60W Single Output with Battery Charger(UPS Function) PSC-60 SERIES PSC-60 60 Watt Battery s Charger e r i e s Power Supply Measures: 5.00 x 3.00 x 1.22” ■ � �   L-Bracket and cover available (PSC-60x-C, x=A,B) �       �        �   �    �    �­  Bauar t gepruft Sicherheit egel ma ge od o s be wac g www. tuv.com ID 2000000000 SPECIFICATION  ”   Ÿ“† ¡“Ÿ † Ÿ–   MODEL OUTPUT CH1 CH2 CH1 CH2 DC VOLTAGE 13.8V 13.8V 27.6V 27.6V RATED CURRENT 2.8A 1.5A 1.4A 0.75A CURRENT RANGE 0 ~ 4.3A -------- 0 ~ 2.15A -------- RATED POWER 59.34W RIPPLE & NOISE (max.) Note.2 120mVp-p -------- ±0.5% -------- LOAD REGULATION ±0.5% -------- ±0.5% -------- Note.4 800ms, 50ms/230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE 50ms/230VAC 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz 1600ms, 50ms/115VAC at full load 10ms/115VAC at full load 127 ~ 370VDC 84% EFFICIENCY (Typ.) 84% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.6A/115VAC 1A/230VAC COLD START 30A/115VAC 60A/230VAC LEAKAGE CURRENT <1mA / 240VAC OVERLOAD 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1:14.49 ~ 18.63V CH1:28.98 ~ 37.26V BATTERY CUT OFF Protection type : Hiccup mode, recovers automatically after fault condition is removed 21±1V 10.5±0.5V AC OK TTL open collector output, ON : AC OK ; OFF : AC Fail ; Ice : max. 30mA@ 50VDC BATTERY LOW VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE NOTE -------- -------- WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT OTHERS -------- ±0.5% WORKING TEMP. (Note 7) 240mVp-p LINE REGULATION OVER VOLTAGE EMC -------- CH1: 24 ~ 29V ±1.0% CH1: 12 ~ 15V VOLTAGE TOLERANCE Note.3 ±1.0% PROTECTION FUNCTION 59.34W VOLTAGE ADJ. RANGE SETUP, RISE TIME INPUT PSC-60B PSC-60A OUTPUT NUMBER TTL open collector output, ON : Battery Low ; OFF : Battery OK ; Ice : max. 30mA@ 50VDC Battery low voltage : < 11V -20 ~ +70℃ (Refer to "Derating Curve") Battery low voltage : < 22V 20 ~ 90% RH non-condensing -20 ~ +85℃, 10 ~ 95% RH ±0.03%/℃ (0~50℃) on CH1 output 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE EMC EMISSION I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC IMMUNITY MTBF Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A DIMENSION PACKING 589.7K hrs min. MIL-HDBK-217F (25℃) PCB:101.6*50.8*29mm (L*W*H) ; Enclosed type:103.4*62*37mm (L*W*H) PCB:0.13Kg; 96pcs/13.5Kg/0.89CUFT ; Enclosed type:0.29Kg; 45pcs/14Kg/0.67CUFT €‚ƒ   ­„…†    ­‡℃ € ­€ˆ‰  ­ Š‹    ­Œ       €‰Ž‘ € „€ƒ   †     € Ž€’     €ƒ‚      € ‡€Š“Š†Š­   € ”€Š“Š      € ‘€ƒ            •€ – —      „”˜„”    “€ƒ •    –  €        – † ™– š    €›œ   € € ž File Name:PSC-60-SPEC 2015-08-06 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: http://power.sager.com/mean-well-PSC-60-power-supply.html (866) 588-1750 p o w e r @ s a g e r. c o m h t t p : / / p o w e r. s a g e r. c o m MEAN WELL PSC-60 SERIES 60 Watt Battery Charger Power Supply PSC-60 s e r5.00 i e sx 3.00 x 1.22” Measures: 60W Single Output with Battery Charger(UPS Function) Mechanical Specification Unit:mm 101.6 3.175 95.25 HS2 50.8 44.45 FS1 3 2 1 Cover: No.998A -T 3.175 M2 AC FUSE T2.5A/250V SVR1 1 2 3 4 5 6 CN1 CN2 HS1 M1 3 max. 29 4-ψ3.3 Mylar film                   Pin No. 1 2 3 Assignment AC/N No Pin AC/L Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent 18 14.5 AC Input Connector (CN1) : JST B3P-VH or equivalent 4.2 L-Bracket: No.998A -D 12. 7 2-M 2-M 95 3L =4 3 78 2-ψ DC Output Connector (CN2) : JST B6P-VH or equivalent Assignment Bat. Low AC OK Battery - Pin No. Assignment 4 Battery + 5 DC Output + 6 DC Output COM 3.5 Mating Housing JST VHR or equivalent Terminal 2-M JST SVH-21T-P1.1 or equivalent 10 3.4 3L 37 Pin No. 1 2 3 =4 55 24 30.8 .2 5 62 : Grounding Required Block Diagram AC OK Bat. Low ALARM CIRCUIT I/P EMI FILTER RECTIFIERS & FILTER POWER SWITCHING RECTIFIERS & FILTER DETECTION CIRCUIT FG O.L.P. CONTROL O.V.P. +V -V Bat. + Bat. Battery Charger & Back Up Control File Name:PSC-60-SPEC 2015-08-06 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: http://power.sager.com/mean-well-PSC-60-power-supply.html (866) 588-1750 p o w e r @ s a g e r. c o m h t t p : / / p o w e r. s a g e r. c o m MEAN WELL PSC-60 SERIES 60 Watt Battery Charger Power Supply PSC-60 s e r5.00 i e sx 3.00 x 1.22” Measures: 60W Single Output with Battery Charger(UPS Function) Output Derating Output Derating VS Input Voltage 100 100 PCB only 90 80 80 Enclosed tpye 70 LOAD (%) LOAD (%) 60 40 20 -20 0 10 20 30 35 40 50 60 60 50 40 70 (HORIZONTAL) 90 95 100 AMBIENT TEMPERATURE (℃) 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz Suggested Application 1.Backup connection for AC interruption (1) Please refer to the Fig1.1 for suggested connection. The power supply charges the battery and provides energy to the load at the same time when the AC main is OK. The battery starts to supply power to the load when the AC mains fails. + A : 12V B : 24V Battery BatBat+ DC+ DC- + - Load Fig 1.1 Suggested system connection 2.Alarm Signal for AC OK and Battery Low (1) Alarm Signal is sent out through " AC OK " & " Battery Low " pins. (2) An external voltage source is required for this function. The maximum applied voltage is 50V and the maximum sink current is 30mA. (3) Table2.1 explains the alarm function built in the power supply Function AC OK Battery Low Description Output of alarm The signal is "Low" when the power supply turns on Low (0.3V max. at 30mA) The signal turns to be "High" when the power supply turns OFF High or open(External applied voltage 50V max.) The signal is "Low" when the voltage of battery is under A:11V, B:22V Low (0.3V max. at 30mA) The signal is "High" when the voltage of battery is above A:11V, B:22V High or open(External applied voltage 50V max.) Table 2.1 Explanation of Alarm Signal AC OK (Battery low) R V Pin6 DC output com External voltage and R (The max. Sink is 30mA and 50V) Fig 2.2 Internal circuit of AC OK (Battery Low) File Name:PSC-60-SPEC 2015-08-06 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: http://power.sager.com/mean-well-PSC-60-power-supply.html (866) 588-1750 p o w e r @ s a g e r. c o m h t t p : / / p o w e r. s a g e r. c o m