Transcript
www.neophotonics.com
VER 000 / 300108
PTB3830-553(4)3W-LC/PC(+) 1.25Gbps 40km Single Fiber BiDi SFP Transceiver 1 Features 1.2 Transceiver unit with 1490nm DFB Laser diode transmitter 1310nm InGaAs PIN photodiode receiver 1.3 Compliant with SFP MSA and SFF-8472 with LC receptacle 1.4 Digital diagnostic monitoring and external calibration 1.5 Hot-pluggable 1.6 Metal enclosure for lower EMI 1.7 +3.3V Single power supply 1.8 LVPECL logic interface simplifies interface to external circuitry 1.9 LVTTL logic level RX LOS 1.10 With pull de-latch 1.11 Operate typical data rate:1.25Gb/s; 1.12 Operate temperature from -40 to 85°C or -5 to 70°C 1.13 40 km reach with 9/125 µm single mode fiber (SMF) 1.14 Complies with RoHS directive (2002/95/EC)
2 Applications 2.2 Point to Point FTTH Application 2.3 Fiber Channel 2.4 Gigabit Ethernet
3 General The optical transceiver is compliant with the Small Form-Factor Pluggable (SFP) Multi-Source Agreement (MSA) and SFF-8472. It offers previously unavailable system cost, upgrade, and reliability benefits by virtue of being hot-pluggable. The optical transceiver is ROHS compliant, each of the components is lead-free.
1 of 11 NeoPhotonics Corporation 2911 Zanker Road San Jose, CA 95134, USA Tel: 408.232.9200 Fax: 408.456.2971 Email:
[email protected]
NeoPhotonics China PHOTON BLD, 12th South Keji Rd. South Hi-Tech Industrial Park, P.C.: 518057 Shenzhen, China Tel: +86 755 26748283(7) Fax: +86 755 26748186 Email:
[email protected]
PTB3830-553(4)3W-LC/PC(+) 1.25Gbps 40km Single Fiber BiDi SFP Transceiver
RD+/LOS
Post Amp
PINTIA WDM
TD+/TxDis TxFault
LD Driver
LD Temp
Vcc SDA
EEPROM Memory
SCL
A/D convertor Digital Diagnostic Monitoring Interface
Fig 1 Block Diagram
The module provides digital diagnostic information of its operating conditions and status, including transmitting power, laser bias current, module temperature, and supply voltage. Calibration and alarm/warning threshold data are written and stored in internal memory (EEPROM). The memory map is compatible with SFF-847, as shown in Fig. 2.
2 wire address 1010000X (A0h) 0 Serial ID Defined by SFP MSA (96 bytes) 95 Vendor Specific (32 bytes) 127 Reserved (128 bytes) 255
2 wire address 1010001X (A2h) 0 Alarm and Warning Thresholds (56 bytes) 55 Cal Constants (40 bytes) 95 Real Time Diagnostic Interface (24 bytes) 119 Vendor Specific (8 bytes) 127 User Writable EEPROM (120 bytes) 247 Vendor Specific (8 bytes) 255
Fig 2 EEPROM Information
The diagnostic data are raw A/D values and must be converted to real world units using calibration constants stored in EEPROM locations 56 – 95 in A2h. 2 of 11 NeoPhotonics Corporation 2911 Zanker Road San Jose, CA 95134, USA Tel: 408.232.9200 Fax: 408.456.2971 Email:
[email protected]
NeoPhotonics China PHOTON BLD, 12th South Keji Rd. South Hi-Tech Industrial Park, P.C.: 518057 Shenzhen, China Tel: +86 755 26748283(7) Fax: +86 755 26748186 Email:
[email protected]
PTB3830-553(4)3W-LC/PC(+) 1.25Gbps 40km Single Fiber BiDi SFP Transceiver
4 Performance Specifications 4.1 Absolute Maximum Ratings Parameter
Symbol
Min.
Max.
Unit
Note
Storage Temperature
Tst
-40
+85
°C
-
Operating Case Temperature
Tc
-5
+70
-40
85
-
GND
Vcc
V
-
Vcc-Vee
-0.5
+3.6
V
-
Input Voltage Power Supply Voltage
1
°C
2
4.2 Recommended Operating Conditions Parameter
Symbol
Min.
Typ.
Max.
Unit
Note
Power Supply Voltage
Vcc
+3.135
+3.3
+3.465
V
-
Case Temperature (Operating)
TC
-5
25
+70
-40
25
85
-
1250
-
Data Rate
-
1
°C
2
Mb/s
-
4.3 Transmitter E-O Characteristics (Tc=-5 to 70°C for PT3830-5533W-LC/PC(+) and Tc=-40 to 85°C for PT3830-5543W-LC/PC(+), Vcc=3.135 to 3.465V unless otherwise specified) Parameter
Symbol
Min.
Typ.
Max.
Unit
Note
λ
1480
1490
1500
nm
-
∆λ
-
-
1
nm
-
Side Mode Suppression Ratio
SMSR
30
-
-
dB
-
Average Optical Output Power
Po
-3
-
2
dBm
-
-45
dBm
Center Wavelength Spectral Width (-20dB)
Average Launch Power of OFF Transmitter Extinction Ratio
Er
6
-
-
dB
-
Power Supply Current
Icc
-
70
170
mA
3
Transmitter Enable Voltage
VEN
0
-
0.8
V
-
Transmitter Disable Voltage
VD
2.0
-
Vcc
V
-
Input Differential Impedance
ZIN
80
120
Ohm
-
Single Ended Data Input Swing
Vpp
250
1200
mV
-
Optical Eye
-
IEEE 802.3ah Compatible
4
3 of 11 NeoPhotonics Corporation 2911 Zanker Road San Jose, CA 95134, USA Tel: 408.232.9200 Fax: 408.456.2971 Email:
[email protected]
NeoPhotonics China PHOTON BLD, 12th South Keji Rd. South Hi-Tech Industrial Park, P.C.: 518057 Shenzhen, China Tel: +86 755 26748283(7) Fax: +86 755 26748186 Email:
[email protected]
PTB3830-553(4)3W-LC/PC(+) 1.25Gbps 40km Single Fiber BiDi SFP Transceiver
4.4 Receiver O-E Characteristics (Tc=-5 to 70°C for PT3830-5533W-LC/PC(+) and Tc=-40 to 85°C for PT3830-5543W-LC/PC(+), Vcc=3.135 to 3.465V unless otherwise specified) Parameter
Symbol
Min.
Typ.
Max.
Unit
Note
-
1260
1310
1360
nm
-
Sensitivity
Pr
-
-
-19.5
dBm
5
Saturation
Ps
-3
-
-
dBm
5
-12
dB
-
Operate Wavelength
Receiver Reflectance LOS Asserted
-
-45
-
-
dBm
High
LOS De-Asserted
-
-
-
-19.5
dBm
level:
LOS Hysteresis
-
0.5
-
4
dB
Alarm
Power Supply Current
Icc
-
80
130
mA
3
Single Ended Data Output Swing
VPP
185
-
1000
mV
-
LOS Low Voltage
VLout
0
-
0.8
V
-
LOS High Voltage
VHout
2.0
-
Vcc
V
-
Notes: 1
For PTB3830-5533W-LC/PC(+)
2
For PTB3830-5543W-LC/PC(+)
3
The current excludes the output load current.
4
Eye mask diagram with at least 10% margin
5
Minimum Sensitivity and saturation levels for a 27-1 NRZ PRBS. BER≤10-12, 1.25Gpbs, ER=6dB
6 EEPROM Information 5.1 EEPROM Serial ID Memory Contents (A0h) Addr.
(decimal)
Field Size
Name of Field
(Bytes)
Content
Content
(Hex)
(Decimal)
Description
0
1
Identifier
03
3
SFP
1
1
Ext. Identifier
04
4
MOD4
2
1
Connector
07
7
LC
3-10
8
Transceiver
00 00 00 40 00 00 00 00
00 00 00 64 00 00 00 00
Transmitter Code
11
1
Encoding
01
1
8B10B
12
1
BR, nominal
0C
12
1.25Gbps
13
1
Reserved
00
0
-
14
1
28
40
40km
15
1
Length (9um)
FF
255
40km
16
1
Length (50um)
00
0
-
17
1
00
0
-
Length (9um)-km
Length (62.5um)
4 of 11 NeoPhotonics Corporation 2911 Zanker Road San Jose, CA 95134, USA Tel: 408.232.9200 Fax: 408.456.2971 Email:
[email protected]
NeoPhotonics China PHOTON BLD, 12th South Keji Rd. South Hi-Tech Industrial Park, P.C.: 518057 Shenzhen, China Tel: +86 755 26748283(7) Fax: +86 755 26748186 Email:
[email protected]
PTB3830-553(4)3W-LC/PC(+) 1.25Gbps 40km Single Fiber BiDi SFP Transceiver
18
1
Length (copper)
00
0
-
19
1
Reserved
00
0
-
4E 45 4F 50 48 4F 54 4F 4E 49 43 53 20 20 20 20
78 69 79 80 72 79 84 79 78 73 67 83 32 32 32 32
‘NEOPHOTONICS’ (ASCⅡ)
20-35
16
Vendor name
36
1
Reserved
00
0
-
37-39
3
Vendor OUI
00 00 00
000
-
80 84 66 51 56 51 48 45 53 53 xx 51 87 76 67 xx
‘PTB3830-55x3WLC(+)’ (ASCⅡ)
40-55
16
Vendor PN
50 54 42 33 38 33 30 2D 35 35 xx 33 57 4C 43 xx
56-59
4
Vendor rev
00 00 00 20
00 00 01 32
“000” (ASCⅡ)
60-61
2
Wavelength
05 D2
05 210
1490
62
1
Reserved
00
0
-
63
1
CC BASE
-
-
64
1
Reserved
00
0
65
1
Options
1A
26
66
1
BR, max
00
0
-
67
1
BR, min
00
0
-
68-83
16
Vendor SN
-
-
ASCⅡ
84-91
8
Vendor date
-
-
92
1
DDM Type
58
88
93
1
94
1
95
1
96-255
160
Enhanced Option SFF-8472 Compliance CC EXT
Check sum of bytes 0 62
Year (2 bytes), Month (2 bytes), Day (2 bytes)
External Calibrated LOS, TX_FAULT and
B0
176
Alarm/warning flags implemented
02
2
-
-
SFF-8472 Rev9.5 Check sum of bytes 64 94
Vendor spec
5 of 11 NeoPhotonics Corporation 2911 Zanker Road San Jose, CA 95134, USA Tel: 408.232.9200 Fax: 408.456.2971 Email:
[email protected]
NeoPhotonics China PHOTON BLD, 12th South Keji Rd. South Hi-Tech Industrial Park, P.C.: 518057 Shenzhen, China Tel: +86 755 26748283(7) Fax: +86 755 26748186 Email:
[email protected]
PTB3830-553(4)3W-LC/PC(+) 1.25Gbps 40km Single Fiber BiDi SFP Transceiver
5.2 Alarm and Warning Thresholds (Serial ID A2H): PTB3830-5533W-LC/PC(+)
Temp (℃)
Voltage (V)
Bias (mA)
TX Power (dBm)
RX Power (dBm)
High Alarm
90
3.6
90
2
-3
Low Alarm
-20
3
0
-3
-22
High Warning
70
3.5
70
1
-5
Low Warning
-15
3.1
0
-2
-20
Temp (℃)
Voltage (V)
Bias (mA)
TX Power (dBm)
RX Power (dBm)
High Alarm
105
3.6
90
2
-3
Low Alarm
-45
3
0
-3
-22
High Warning
85
3.5
70
1
-5
Low Warning
-40
3.1
0
-2
-20
Parameter(Unit)
PTB3830-5543W-LC/PC(+)
Parameter(Unit)
5.3 Digital Diagnostic Monitor Accuracy Parameter
Unit
Accuracy
Tx Optical Power
dB
±3
Rx Optical Power
dB
±3
Bias Current
%
±10
%
±3
℃
±3
Power
Supply
Voltage Internal Temperature
Range Po: -3~2dBm, Recommended operation conditions Pi: -19.5~-3dBm, Recommended operation conditions Id: 1-100mA, Recommended operating conditions Recommended operating conditions Recommended operating conditions
Calibration External
External
External External External
6 of 11 NeoPhotonics Corporation 2911 Zanker Road San Jose, CA 95134, USA Tel: 408.232.9200 Fax: 408.456.2971 Email:
[email protected]
NeoPhotonics China PHOTON BLD, 12th South Keji Rd. South Hi-Tech Industrial Park, P.C.: 518057 Shenzhen, China Tel: +86 755 26748283(7) Fax: +86 755 26748186 Email:
[email protected]
PTB3830-553(4)3W-LC/PC(+) 1.25Gbps 40km Single Fiber BiDi SFP Transceiver
7 Pin Definitions 6.1 Pin Diagram
20
VeeT
1
VeeT
19
TD-
2
Tx Fault
18
TD+
3
Tx Disable
17
VeeT
4
MOD-DEF(2)
16
VccT
5
MOD-DEF(1)
15
VccR
6
MOD-DEF(0)
14
VeeR
7
Rate Select
13
RD+
8
LOS
12
RD-
9
VeeR
11
VeeR
10
VeeR
Bottom of Board (as viewed thru top of board)
Top of Board
6.2 Pin Descriptions Pin#
Name
Function
Notes
1
VeeT
Transmitter Ground
-
2
TX Fault
Transmitter Fault Indication
Note 1
3
TX Disable
Transmitter Disable
Note 2, Module disables on high or open
4
MOD-DEF2
Module Definition 2
Note 3, 2 wire serial ID interface
5
MOD-DEF1
Module Definition 1
Note 3, 2 wire serial ID interface
6
MOD-DEF0
Module Definition 0
Note 3, Grounded in Module
7
Rate Select
Not use
-
8
LOS
Loss of Signal
Note 4
9
VeeR
Receiver Ground
Note 5
10
VeeR
Receiver Ground
Note 5
11
VeeR
Receiver Ground
Note 5
12
RD-
Inv. Received Data Out
Note 6
13
RD+
Received Data Out
Note 6
14
VeeR
Receiver Ground
Note 5
15
VccR
Receiver Power
Note 7, 3.3V± 5%
16
VccT
Transmitter Power
Note 7, 3.3V± 5%
17
VeeT
Transmitter Ground
Note 5
7 of 11 NeoPhotonics Corporation 2911 Zanker Road San Jose, CA 95134, USA Tel: 408.232.9200 Fax: 408.456.2971 Email:
[email protected]
NeoPhotonics China PHOTON BLD, 12th South Keji Rd. South Hi-Tech Industrial Park, P.C.: 518057 Shenzhen, China Tel: +86 755 26748283(7) Fax: +86 755 26748186 Email:
[email protected]
PTB3830-553(4)3W-LC/PC(+) 1.25Gbps 40km Single Fiber BiDi SFP Transceiver
Pin#
Name
Function
Notes
18
TD+
Transmit Data In
Note 8
19
TD-
Inv. Transmit Data In
Note 8
20
VeeT
Transmitter Ground
Note 5
Notes: 1. TX Fault is an open collector/drain output, which should be pulled up with a 4.7K–10KΩ resistor on the host board. Pull up voltage between 2.0V and VccT, R+0.3V. When high, output indicates a laser fault of some kind. Low indicates normal operation. In the low state, the output will be pulled to < 0.8V. 2. TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module with a 4.7–10 KΩ resistor. Its states are: Low (0 – 0.8V):
Transmitter on
(>0.8, < 2.0V):
Undefined
High (2.0 – 3.465V):
Transmitter Disabled
Open:
Transmitter Disabled
3. Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7K – 10KΩ resistor on the host board. The pull-up voltage shall be VccT or VccR. Mod-Def 0 is grounded by the module to indicate that the module is present Mod-Def 1 is the clock line of two wire serial interface for serial ID Mod-Def 2 is the data line of two wire serial interface for serial ID 4. LOS (Loss of Signal) is an open collector/drain output, which should be pulled up with a 4.7K – 10KΩ resistor. Pull up voltage between 2.0V and VccT, R+0.3V. When high, this output indicates the received optical power is below the worst-case receiver sensitivity (as defined by the standard in use). Low indicates normal operation. In the low state, the output will be pulled to < 0.8V. 5. VeeR and VeeT may be internally connected within the SFP module. 6. RD-/+: These are the differential receiver outputs. They are AC coupled 100Ω differential lines which should be terminated with 100Ω (differential) at the user SERDES. The AC coupling is done inside the module and is thus not required on the host board. 7. VccR and VccT are the receiver and transmitter power supplies. They are defined as 3.3V ±5% at the SFP connector pin. Maximum supply current is 300mA. Recommended host board power supply filtering is shown below. Inductors with DC resistance of less than 1Ω should be used in order to maintain the required voltage at the SFP input pin with 3.3V supply voltage. When the recommended supply filtering network is used, hot plugging of the SFP transceiver module will result in an inrush current of no more than 30 mA greater than the steady state value. VccR and VccT may be internally connected within the SFP transceiver module. 8. TD-/+: These are the differential transmitter inputs. They are AC-coupled, differential lines with 100Ω differential termination inside the module. The AC coupling is done inside the module and is thus not required on the host board.
8 of 11 NeoPhotonics Corporation 2911 Zanker Road San Jose, CA 95134, USA Tel: 408.232.9200 Fax: 408.456.2971 Email:
[email protected]
NeoPhotonics China PHOTON BLD, 12th South Keji Rd. South Hi-Tech Industrial Park, P.C.: 518057 Shenzhen, China Tel: +86 755 26748283(7) Fax: +86 755 26748186 Email:
[email protected]
PTB3830-553(4)3W-LC/PC(+) 1.25Gbps 40km Single Fiber BiDi SFP Transceiver
7 Mechanical Specifications
(Unit mm /inch)
LC Receptacle
8 Recommended Circuit VCC 10uF
0.1uF 1uH
RES
Vcc_T 0.1uF RES Tx_Disable Tx_Fault Z=50 ohms
TD+
Z=50 ohms
TD-
C R
Laser Driver &eye safety circuitry
C Protocol
IC
Vcc_R
SerDes IC 10uF
R
0.1uF
Z=50 ohms
RD+
Z=50 ohms
RD-
AMPLIFICATION &QUANTIZATION
C
VCC RES
C
RES
RES
REF_RATE
RES Rx_LOS
mod_def2 mod_def1 mod_def0
PLD/PAL
EEPROM
VEER
NOTE: 4.7K ohms
1000ppm, e.g. soldering material, or the terminals, Pins of electronic components, or pads of printed circuit board, exempted by RoHS(2002/95/EC) directive. Other materials (excluded exempted material) comply with threshold value of RoHS banned substance in homogenous material. 10.2. RoHS-6 compliant product: Qualified as RoHS compliant and lead-free product based on lead-free soldering process, all materials (excluded exempted material) comply with threshold value of RoHS banned substance in homogenous material.
10 of 11 NeoPhotonics Corporation 2911 Zanker Road San Jose, CA 95134, USA Tel: 408.232.9200 Fax: 408.456.2971 Email: [email protected]
NeoPhotonics China PHOTON BLD, 12th South Keji Rd. South Hi-Tech Industrial Park, P.C.: 518057 Shenzhen, China Tel: +86 755 26748283(7) Fax: +86 755 26748186 Email: [email protected]
PTB3830-553(4)3W-LC/PC(+) 1.25Gbps 40km Single Fiber BiDi SFP Transceiver
11 Ordering Information Part Number
Operating Case Temperature
RoHS Compliant
PTB3830-5533W-LC/PC
-5 ~ +70°C
RoHS-5
PTB3830-5543W-LC/PC
-40 ~ +85°C
RoHS-5
PTB3830-5533W-LC/PC+
-5 ~ +70°C
RoHS-6
PTB3830-5543W-LC/PC+
-40 ~ +85°C
RoHS-6
11 of 11 NeoPhotonics Corporation 2911 Zanker Road San Jose, CA 95134, USA Tel: 408.232.9200 Fax: 408.456.2971 Email: [email protected]
NeoPhotonics China PHOTON BLD, 12th South Keji Rd. South Hi-Tech Industrial Park, P.C.: 518057 Shenzhen, China Tel: +86 755 26748283(7) Fax: +86 755 26748186 Email: [email protected]