Preview only show first 10 pages with watermark. For full document please download

Ptu300 Order Form Global

   EMBED


Share

Transcript

Order form Purchaser Valid from March 2016 Order no. Combined Pressure, Humidity and Temperature Transmitter PTU301 For Wall Mounting 1 1 2 3 4 5 6 7 8-10 Vaisala Combined Pressure, Humidity and Temperature Transmitter PTU300 1 Transmitter type PTU301 for wall mounting 1 Pressure range 500...1100 hPa Class A / one sensor 500...1100 hPa Class B / one sensor 500...1100 hPa Class A / two sensors 500...1100 hPa Class B / two sensors 50...1100 hPa One sensor, class B only 50...1100 hPa Two sensors, class B only Wall mount probe fixed with short cable Probe holder plate recommended in selection 17 Additional temperature probe No probe Display No display Graphical display with keypad Power supply 10...35 VDC, 24 VAC 10...35 VDC, 24 VAC with galvanic isolation Universal AC power (100....240 VAC) Universal AC power (100....240 VAC) + US power cord Universal AC power (100....240 VAC) + UK power cord Universal AC power (100....240 VAC) + AUS power cord Universal AC power (100....240 VAC) + EURO power cord External US AC-adapter (for LAN/WLAN interface in USA and Canada) Not IP65 Output signal RS232C only, no analog outputs 4... 20 mA RS232C + Analog outputs (Ch1 & Ch2, optional Ch3 ) 0... 20 mA RS232C + Analog outputs (Ch1 & Ch2, optional Ch3 ) 0... 1 V RS232C + Analog outputs (Ch1 & Ch2, optional Ch3 ) 0... 5 V RS232C + Analog outputs (Ch1 & Ch2, optional Ch3 ) 0... 10 V RS232C + Analog outputs (Ch1 & Ch2, optional Ch3 ) Parameter and scaling for No Analog output RH (0...100 %RH) analog output (Ch1, Ch2, Ch3 ) T (range: see below) Td (-20...100 °C) (-4...+212 °F) Tdf (-20...100 °C) (-4...+212 °F) a (0...600 g/m3) (0...262 gr/ft3) Tw (0...100 °C) (+32...+212 °F) x (0...500 g/kg d.a) (0...3500 gr/lb) h (-40...1500 kJ/kg) (-9.5...+652.6 Btu/lb) pw (0…1000 hPa) (0…14.5 psi) pws (0…1000 hPa) (0…14.5 psi) dT (-10...+50 °C) (14...+122 °F) P (pressure range: selection in step 2) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 0 1 PRICE 0 1 2 3 4 5 6 A 8 0 0 1 A B C D E F G K 0 1 2 3 4 5 A B C D E F G H J K L M A A B C D E F G H J K L M P Define quantity for Ch1:_______________ Ch2:______________ X X X Define scale for Ch1:_______________ Ch2:______________ Ch3:______________ Channel 1 Note: - If any analog outputs selected, please specify at least Ch1 & Ch2 parameters and scalings Channel 2 - 3rd analog output (Ch3) is not possible with two pressure sensors or an optional module Channel 3 only for pressure (optional) Analog output range No temperature output Mandatory if no analog T outputs selected (-40...+140 °F) for temperature -40...+60 °C (-4...+140 °F) -20...+60 °C (+32...+140 °F) 0...+60 °C special range :_______________________________ Output format Standard Output units Metric Non-metric Optional module No module Mandatory with two pressure sensors or 3rd analog output Relay output Not possible with universal AC power module Note: Up to one optional RS485 serial interface (galvanically isolated) module can be LAN (Ethernet) interface + 2 m cable (RJ45) Please see note *) below, not possible with D9-adapter and 8-pole connectors selected WLAN (Wireless Ethernet) interface + antenna With short cable probe only, not possible with D9-adapter and 8-pole connectors Data logger module Cable bushings Cable gland M20*1.5 Note: The universal AC power Conduit fitting NPT1/2" must not be connected 8-pole connector with 5m cable spare cable: 212142 through the 8-pole connector 8-pole counter connector with screw terminals spare connector: 212416 or D9 adapter D9-adapter Only for RS232C, RS485 and DC supply Pressure fitting Barbed fitting for 1/8" hose Quick connector with shutoff valve for 1/8" hose Transmitter installation Normal mounting Wall mounting plate item: 214829 Pole installation kit item: 215108 Pole installation kit with Rain Shield item: 215109 DIN rail kit item: 215094 Probe holder plate Recommended with short cable probe Humidity sensor General purpose and high chemical concentrations HUMICAP180R Composite sensor with chemical purge option HUMICAP180RC General purpose HUMICAP180 Composite sensor with chemical purge option HUMICAP180C Sensor protection PPS plastic grid & stainless steel netting spare: DRW010281SP PPS plastic grid spare: DRW010276SP Sintered stainless steel filter spare: HM47280SP Stainless steel grid spare: HM47453SP Vaporized hydrogen peroxide (VHP) resistant filter spare: 231865 Probe installation accessories No probe installation accessories User's Guide language No User's Guide English pdf user guides available at: French www.vaisala.com/ptu300 Japanese PC Accessories No Service cable for PC, RS232 (D9 female connector) item: 19446ZZ MI70LINK software for Windows® with RS232 service cable item: 215005 Service cable for PC, USB item: 219685 MI70LINK software for Windows® with USB service cable item: 219916 Calibration ISO9001 compliant factory calibration service item: PTUCALA Special calibration See separate order form service item: 223937 Special 11 12 13 14 15 16 17 18 19 20 21 22 23 *) Note! Simultaneous installation of LAN and Universal AC-power is possible only with a short cable probe. A B F K X 1 A B 0 1 2 4 5 6 A B C D E 1 2 A B C D E F A C 1 4 B C D E G 0 A B D J 0 1 2 3 4 A X TOTAL QTY TOTAL VALUE Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Example of order code with typical settings: PTU300 1 1 A 0 1 A 1 B C P B 1 A 0 A 1 A A B 0 B 0 A End customer: Order form Purchaser Valid from March 2016 Order no. Combined Pressure, Humidity and Temperature Transmitter PTU303 For General Use 1 Vaisala Combined Pressure, Humidity and Temperature Transmitter PTU300 for general use Transmitter type PTU303 2 Pressure range 500...1100 hPa Class A / one sensor 500...1100 hPa Class B / one sensor 500...1100 hPa Class A / two sensors 500...1100 hPa Class B / two sensors 50...1100 hPa One sensor, class B only 50...1100 hPa Two sensors, class B only 3 Probe cable length 2 m cable, +80 °C 5 m cable, +80 °C 10 m cable, +80 °C 20 m cable, +80 °C 4 Additional temperature probe No probe 5 Display No display Graphical display with keypad 6 Power supply 10...35 VDC, 24 VAC 10...35 VDC, 24 VAC with galvanic isolation Universal AC power (100....240 VAC) Universal AC power (100....240 VAC) + US power cord Universal AC power (100....240 VAC) + UK power cord Universal AC power (100....240 VAC) + AUS power cord Universal AC power (100....240 VAC) + EURO power cord External US AC-adapter (for LAN/WLAN interface in USA and Canada) Not IP65 7 Output signal RS232C only, no analog outputs RS232C + Analog outputs (Ch1 & Ch2, optional Ch3 ) 4... 20 mA RS232C + Analog outputs (Ch1 & Ch2, optional Ch3 ) 0... 20 mA RS232C + Analog outputs (Ch1 & Ch2, optional Ch3 ) 0... 1 V RS232C + Analog outputs (Ch1 & Ch2, optional Ch3 ) 0... 5 V RS232C + Analog outputs (Ch1 & Ch2, optional Ch3 ) 0... 10 V 8-10 Parameter and scaling for No Analog output analog output (Ch1, Ch2, Ch3 ) RH (0...100 %RH) T (range: see below) Td (-20...100 °C) (-4...+212 °F) Tdf (-20...100 °C) (-4...+212 °F) a (0...600 g/m3) (0...262 gr/ft3) Tw (0...100 °C) (+32...+212 °F) x (0...500 g/kg d.a) (0...3500 gr/lb) h (-40...1500 kJ/kg) (-9.5...+652.6 Btu/lb) pw (0…1000 hPa) (0…14.5 psi) pws (0…1000 hPa) (0…14.5 psi) dT (-10...+50 °C) (14...+122 °F) P (pressure range: selection in step 2) 1 2 3 3 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 0 1 1 2 3 4 5 6 B C D P 0 0 1 A B C D E F G K 0 1 2 3 4 5 A B C D E F G H J K L M A A B C D E F G H J K L M P Define quantity for Ch1:_______________ Ch2:______________ X X X Define scale for Ch1:_______________ Ch2:______________ Ch3:______________ Channel 1 Note: - If any analog outputs selected, please specify at least Ch1 & Ch2 parameters and scalings Channel 2 - 3rd analog output (Ch3) is not possible with two pressure sensors or an optional module Channel 3 only for pressure (optional) Analog output range No temperature output Mandatory if no analog T outputs selected A (-40...+140 °F) for temperature -40...+60 °C B (-4...+140 °F) -20...+60 °C F (+32...+140 °F) 0...+60 °C K special range :_______________________________ X Output format Standard 1 Output units Metric A Non-metric B Optional module No module Mandatory with two pressure sensors or 3rd analog output 0 Relay output Not possible with universal AC power module 1 Note: Up to one optional RS485 serial interface (galvanically isolated) 2 module can be LAN (Ethernet) interface + 2 m cable (RJ45) Not possible with D9-adapter and 8-pole connectors 4 selected WLAN (Wireless Ethernet) interface + antenna Not possible with D9-adapter and 8-pole connectors 5 Data logger module 6 Cable bushings Cable gland M20*1.5 A Note: The universal AC power Conduit fitting NPT1/2" B must not be connected 8-pole connector with 5m cable spare cable: 212142 C through the 8-pole connector 8-pole counter connector with screw terminals spare connector: 212416 D or D9 adapter D9-adapter Only for RS232C, RS485 and DC supply E Pressure fitting Barbed fitting for 1/8" hose 1 Quick connector with shutoff valve for 1/8" hose 2 Transmitter installation Normal mounting A Wall mounting plate item: 214829 B Pole installation kit separate delivery if 20 m probe item: 215108 C Pole installation kit with Rain Shield separate delivery if 20 m probe item: 215109 D DIN rail kit item: 215094 E General purpose and high chemical concentrations Humidity sensor HUMICAP180R A Composite sensor with chemical purge option HUMICAP180RC C General purpose HUMICAP180 1 Composite sensor with chemical purge option HUMICAP180C 4 spare: DRW010281SP Sensor protection PPS plastic grid & stainless steel netting B spare: DRW010276SP PPS plastic grid C spare: HM47280SP Sintered stainless steel filter D Stainless steel grid spare: HM47453SP E Vaporized hydrogen peroxide (VHP) resistant filter spare: 231865 G Probe installation No kit 0 Duct Installation kit spare: 210697 1 accessories Cable Gland AGRO, M20x1.5 with split seal spare: HMP247CG 2 A User's Guide language No User's Guide B English pdf user guides available at: D French www.vaisala.com/ptu300 J Japanese No PC Accessories 0 Service cable for PC, RS232 (D9 female connector) item: 19446ZZ 1 MI70LINK software for Windows® with RS232 service cable item: 215005 2 Service cable for PC, USB item: 219685 3 MI70LINK software for Windows® with USB service cable item: 219916 4 service item: PTUCALA Calibration ISO9001 compliant factory calibration A Special calibration See separate order form service item: 223937 X TOTAL QTY TOTAL VALUE Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Special 11 12 13 14 15 16 17 18 19 20 21 22 23 Example of order code with typical settings: PTU300 3 1 B 0 1 A 1 B C P B 1 A 0 A 1 A A B 0 B 0 A End customer: PRICE Order form Purchaser Valid from March 2016 Order no. Combined Pressure, Humidity and Temperature Transmitter PTU307 For High Humidities 1 1 2 3 4 5 6 7 8-10 2 3 4 5 Vaisala Combined Pressure, Humidity and Temperature Transmitter PTU300 7 Transmitter type PTU307 with warmed probe 7 Pressure range 500...1100 hPa Class A / one sensor 1 500...1100 hPa Class B / one sensor 2 500...1100 hPa Class A / two sensors 3 500...1100 hPa Class B / two sensors 4 50...1100 hPa One sensor, class B only 5 50...1100 hPa Two sensors, class B only 6 Probe cable length 2m cable, +120 °C E 5 m cable, +120 °C F (dew point probe) 10 m cable, +120 °C G 20 m cable, +120 °C R Additional temperature probe No probe 0 (dew point probe only) Note: RH and T are 2 m cable 1 available only if additional 5 m cable 2 temperature probe is selected 10 m cable 3 20 m cable 7 Display No display 0 Graphical display with keypad 1 Power supply 10...35 VDC, 24 VAC 10...35 VDC, 24 VAC with galvanic isolation Universal AC power (100....240 VAC) Universal AC power (100....240 VAC) + US power cord Universal AC power (100....240 VAC) + UK power cord Universal AC power (100....240 VAC) + AUS power cord Universal AC power (100....240 VAC) + EURO power cord External US AC-adapter (for LAN/WLAN interface in USA and Canada) Not IP65 Output signal RS232C only, no analog outputs 4... 20 mA RS232C + Analog outputs (Ch1 & Ch2, optional Ch3 ) 0... 20 mA RS232C + Analog outputs (Ch1 & Ch2, optional Ch3 ) 0... 1 V RS232C + Analog outputs (Ch1 & Ch2, optional Ch3 ) 0... 5 V RS232C + Analog outputs (Ch1 & Ch2, optional Ch3 ) 0... 10 V RS232C + Analog outputs (Ch1 & Ch2, optional Ch3 ) Parameter and scaling for No Analog output RH (0...100 %RH) analog output (Ch1, Ch2, Ch3 ) Only with additional T probe T (range: see below) Only with additional T probe Td (-20...100 °C) (-4...+212 °F) Tdf (-20...100 °C) (-4...+212 °F) a (0...600 g/m3) (0...262 gr/ft3) Only with additional T probe Tw (0...100 °C) (+32...+212 °F) Only with additional T probe x (0...500 g/kg d.a) (0...3500 gr/lb) h (-40...1500 kJ/kg) (-9.5...+652.6 Btu/lb) Only with additional T probe pw (0…1000 hPa) (0…14.5 psi) pws (0…1000 hPa) (0…14.5 psi) Only with additional T probe dT (-10...+50 °C) (14...+122 °F) Only with additional T probe P (pressure range: selection in step 2) 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 1 A B C D E F G K 0 1 2 3 4 5 A B C D E F G H J K L M A A B C D E F G H J K L M P Define quantity for Ch1:_______________ Ch2:______________ X X X Define scale for Ch1:_______________ Ch2:______________ Ch3:______________ Channel 1 Note: - If any analog outputs selected, please specify at least Ch1 & Ch2 parameters and scalings Channel 2 Channel 3 only for pressure (optional) - 3rd analog output (Ch3) is not possible with two pressure sensors or an optional module Analog output range No temperature output Mandatory if no analog T outputs selected A (-40...+140 °F) for temperature -40...+60 °C B (-4...+140 °F) -20...+60 °C F (+32...+140 °F) K 0...+60 °C special range :_______________________________ X Output format Standard 1 Output units Metric A Non-metric B Optional module No module Mandatory with two pressure sensors or 3rd analog output 0 Relay output Not possible with universal AC power module 1 Note: Up to one optional RS485 serial interface (galvanically isolated) 2 module can be LAN (Ethernet) interface + 2 m cable (RJ45) Not possible with D9-adapter and 8-pole connectors 4 selected WLAN (Wireless Ethernet) interface + antenna Not possible with D9-adapter and 8-pole connectors 5 Data logger module 6 Cable bushings Cable gland M20*1.5 A B Note: The universal AC power Conduit fitting NPT1/2" 8-pole connector with 5m cable spare cable: 212142 C must not be connected 8-pole counter connector with screw terminals spare connector: 212416 D through the 8-pole connector D9-adapter Only for RS232C, RS485 and DC supply E or D9 adapter Pressure fitting Barbed fitting for 1/8" hose 1 Quick connector with shutoff valve for 1/8" hose 2 Transmitter installation Normal mounting A Wall mounting plate item: 214829 B Pole installation kit separate delivery if 20 m probe item: 215108 C Pole installation kit with Rain Shield separate delivery if 20 m probe item: 215109 D DIN rail kit item: 215094 E Humidity sensor Composite sensor HUMICAP180RC B Composite sensor with chemical purge HUMICAP180RC C Composite sensor HUMICAP180C 3 Composite sensor with chemical purge HUMICAP180C 4 Sensor protection PPS plastic grid & stainless steel netting spare: DRW010281SP B PPS plastic grid spare: DRW010276SP C Sintered stainless steel filter spare: HM47280SP D Stainless steel grid spare: HM47453SP E Vaporized hydrogen peroxide (VHP) resistant filter spare: 231865 G Probe installation No kit 0 accessories Duct Installation kit spare: 210697 1 Cable Gland AGRO spare: HMP247CG 2 2 x Duct installation kits spare: 210697 + 215003 6 User's Guide language No User's Guide A English B French D pdf user guides available at: Japanese J www.vaisala.com/ptu300 PC Accessories No 0 Service cable for PC, RS232 (D9 female connector) item: 19446ZZ 1 MI70LINK software for Windows® with RS232 service cable item: 215005 2 Service cable for PC, USB item: 219685 3 MI70LINK software for Windows® with USB service cable item: 219916 4 Calibration ISO9001 compliant factory calibration service item: PTUCALA A Special calibration See separate order form service item: 223937 X TOTAL QTY TOTAL VALUE Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Special 11 12 13 14 15 16 17 18 19 20 21 22 23 Example of order code with typical settings: PTU300 7 1 E 1 1 A 1 B C P B 1 A 0 A 1 A B B 0 B 0 A End customer: PRICE Order form Purchaser Valid from March 2016 Order no. Combined Pressure and Temperature Transmitter PTU30T For Pressure and Temperature Measurement 1 1 2 3 4 5 6 7 8-10 11 12 13 14 15 16 17 18 19 20 21 22 23 Vaisala Combined Pressure and Temperature Transmitter PTU300 Transmitter type PTU30T for pressure and temperature only Pressure range 500...1100 hPa Class A / one sensor 500...1100 hPa Class B / one sensor 500...1100 hPa Class A / two sensors 500...1100 hPa Class B / two sensors 50...1100 hPa One sensor, class B only 50...1100 hPa Two sensors, class B only Temperature probe length 2m cable 5 m cable 10 m cable Additional temperature probe No probe Display No display Graphical display with keypad Power supply 10...35 VDC, 24 VAC 10...35 VDC, 24 VAC with galvanic isolation Universal AC power (100....240 VAC) Universal AC power (100....240 VAC) + US power cord Universal AC power (100....240 VAC) + UK power cord Universal AC power (100....240 VAC) + AUS power cord Universal AC power (100....240 VAC) + EURO power cord External US AC-adapter (for LAN/WLAN interface in USA and Canada) Not IP65 Output signal RS232C only, no analog outputs 4... 20 mA RS232C + Analog outputs (Ch1 & Ch2, optional Ch3 ) 0... 20 mA RS232C + Analog outputs (Ch1 & Ch2, optional Ch3 ) 0... 1 V RS232C + Analog outputs (Ch1 & Ch2, optional Ch3 ) 0... 5 V RS232C + Analog outputs (Ch1 & Ch2, optional Ch3 ) 0... 10 V RS232C + Analog outputs (Ch1 & Ch2, optional Ch3 ) Parameter and scaling for No Analog output analog output (Ch1, Ch2, Ch3 ) T (T range: selection in step 11) P (pressure range: selection in step 2) 2 3 T T 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 0 1 0 A 0 1 2 3 4 5 6 H J K 0 0 1 A B C D E F G K 0 1 2 3 4 5 A A A C C P Special Define scale for Ch1:_______________ Ch2:______________ Ch3:______________ X X X Channel 1 only for T Note: - If any analog outputs selected, please specify at least Ch1 & Ch2 parameters and scalings Channel 2 only for T - 3rd analog output (Ch3) is not possible with two pressure sensors or an optional module Channel 3 only for pressure (optional) Analog output range No temperature output Mandatory if no analog T outputs selected A (-40...+140 °F) for temperature -40...+60 °C B (-4...+140 °F) -20...+60 °C F (+32...+140 °F) K 0...+60 °C special range for T (Ch1 & Ch2) :_______________________________ X Output format Standard 1 Output units Metric A Non-metric B Optional module No module Mandatory with two pressure sensors or 3rd analog output 0 Not possible with universal AC power module Relay output 1 Note: Up to one optional RS485 serial interface (galvanically isolated) 2 Not possible with D9-adapter and 8-pole connectors module can be LAN (Ethernet) interface + 2 m cable (RJ45) 4 selected Not possible with D9-adapter and 8-pole connectors WLAN (Wireless Ethernet) interface + antenna 5 Data logger module 6 Cable bushings Cable gland M20*1.5 A B Note: The universal AC power Conduit fitting NPT1/2" must not be connected 8-pole connector with 5m cable spare cable: 212142 C through the 8-pole connector 8-pole counter connector with screw terminals spare connector: 212416 D Only for RS232C, RS485 and DC supply or D9 adapter D9-adapter E Pressure fitting Barbed fitting for 1/8" hose 1 Quick connector with shutoff valve for 1/8" hose 2 Transmitter installation Normal mounting A Wall mounting plate item: 214829 B Pole installation kit item: 215108 C Pole installation kit with Rain Shield item: 215109 D DIN rail kit item: 215094 E Humidity sensor No humidity sensor 0 Sensor protection No sensor protection A Probe installation accessories No probe installation accessories 0 User's Guide language No User's Guide A English B French D pdf user guides available at: Japanese J www.vaisala.com/ptu300 PC Accessories No 0 Service cable for PC, RS232 (D9 female connector) item: 19446ZZ 1 MI70LINK software for Windows® with RS232 service cable item: 215005 2 Service cable for PC, USB item: 219685 3 MI70LINK software for Windows® with USB service cable item: 219916 4 Calibration ISO9001 compliant factory calibration A service item: PTUCALA Special calibration See separate order form service item: 223937 X TOTAL QTY TOTAL VALUE Selections in bold are included in the prices of the basic versions. Selections in italic are available at an extra price. Example of order code with typical settings: PTU300 T 1 H 0 1 A 1 C C P B 1 A 0 A 1 A 0 A 0 B 0 A End customer: PRICE