Preview only show first 10 pages with watermark. For full document please download

Public Address Amplifier

   EMBED


Share

Transcript

PUBLIC ADDRESS SERIES 6000 Installation and User Instructions AMPLIFIER Cover Models: Two Zone Mixer Amplifier Two Zone Power Amplifier PA 6030 PAB6120 PA 6060 PAB6240 PA 6120 PAB6480 1 WARNING:THIS APPLIANCE MUST BE EARTHED RISK OF ELECTRIC SHOCK DO NOT OPEN IMPORTANT The wires in the mains lead are coloured in accordance with the following code: Green and Yellow: Earth (E) Blue: Neutra (N) Brown : Live (L) As the colours of the wires in the mains lead of this apparatus may not correspond with the coloured markings identifying the terminals in your plug proceed as follows: The wire which is coloured green and yellow must be connected to the terminal which is marked by the letter E or by the safety earth symbol or coloured green and yellow. The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black. The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red. If a 13 Amp (B.S.1363) plug or any other type of plug is used,a 5 Amp fuse must be fitted either in the plug or at the distribution board. GENERAL INSTALLATION DO NOT run microphone cables near mains, data, telephone or 100V line cables. DO NOT run 100V line cables near data, telephone or other low voltage cables. DO NOT exceed 90% of the amplifiers output power when using 100V line (speech only). DO NOT exceed 70% of the amplifiers output power when using 100V line (high level background music). DO NOT use re-entrant horn loudspeakers for background music unless the loudspeaker has been specifically designed for this purpose. AVOID jointing the microphone cable, when this is unavoidable make sure a good screened connector is used, e.g. XLR. ALWAYS use a balanced or floating low impedance microphone terminating into a balanced input on long microphone cable runs. 2 ALWAYS use a mains grade double insulated cable for the loudspeaker cable runs. ENSURE that all loudspeakers are in-phase. ENSURE that there are no short circuits on the loudspeaker line before connecting to the amplifier. FRONT PANEL Two Zone Mixer Amplifier 11 1 2 3 4 5 6 1. Mic1 Volume Control 2. Mic2 Volume Control 3. Mic3 Volume Control 4. Mic4 Volume Control 5. Line Volume Control 6. Aux / CD Selector Switch 7 8 9 12 10 7. Master Tone Control (Bass) 8. Master Tone Control (Treble) 9. Master Volume Control 10. Power On / Off switch 11. Power On / Off indicator LED 12. Output level indicator LED REAR PANEL 18 19 20 21 22 23 24 PHANTOM LINE MIC PHANTOM LINE MIC 25 26 28 29 27 230V~ 115V~ 600 Apparatus delivered Connected for 230v~ 1V 8 1W + P MONITOR OUTPUT MUSIC/SPEECH DC 24V + COM 8 100V COM ~ TEL/EMER 100V MIC 4 2 0 PRE OUT LINE FUSE 1 ~ 3 1. Earth Connection Screw 2. DC power supply terminals 3. Loudspeaker output terminals 4. Power input (RCA phono) 5. Tape output (2X RCA phono) 6. CD input (2X RCA phono) 7. Aux input (2X RCA phono) 8. Mic4 input (XLR-phone / balanced) 5 6 7 8 MIC 3 9 10 11 12 SENS VR SENS VR MIC 2 MIC 1 13 14 15 16 17 16. Mic1 input Sens. control 17. Mic1 input (DIN / balanced) 18. AC fuse holder 19. Mains voltage (115V/ 230V) selector switch 20. Mains input socket 21. Pre output (RCA phono) 22. Mic4 (Line/Phantom/Mic) selector switch. 23. Mic3 (Line/Phantom/Mic) selector switch. 3 9. Mic4 input (DIN / balanced) 10. Mic3 input (XLR-phone / balanced) 11. Mic3 input (DIN / balanced) 12. Mic2 input (XLR / balanced) 13. Mic2 input Sens. control 14. Mic2 input (DIN / balanced) 15. Mic1 input (XLR / balanced) FRONT PANEL 24. Monitor output Level control 25. Monitor output terminals 26. Priority switch terminals 27. TEL/EMER input terminals 28. TEL/EMER input level control 29. Chime On/Off switch Two Zone Power Amplifier (120W & 240W) 1 2 1. Power On / Off switch 2. Power On / Off indicator LED 3. Output level indicator LED REAR PANEL 11 12 13 14 230V~ 115V~ Apparatus delivered Connected for 230v~ OUTPUT INPUT LINE FUSE MASTER VR 1 2 3 4 BALANCED 5 UNBALANCED 6 7 8 BALANCED 9 10 1. Earth Connection Screw 8. Input Socket (2X RCA phnon) 2. DC power supply terminals 9. Input Socket (XLR / balanced) 3. Loudspeaker output terminals 10. Input Socket (phone / balanced) 4. Master Volume control 11. AC fuse holder 4 3 5. Output Socket (Phone / balanced) 12. Mains voltage (115V / 230V) Selector Switch 6. Output Socket (XLR / balanced) 13. Mains input socket 7. Output Socket (2X RCA phono) 14. Priority switch terminals FRONT PANEL Two Zone Power Amplifier (480W) 1 2 3 1. Power On / Off switch 2. Power On / Off indicator LED 3. Output level indicator LED REAR PANEL 11 13 12 LINE FUSE 250V T10.0A OUTPUT MASTER VR 1 2 3 4 BALANCED 5 6 INPUT UNBALANCED 7 1. Earth Connection Screw 8. Input Socket (2X RCA phnon) 2. DC power supply terminals 9. Input Socket (XLR / balanced) 5 8 BALANCED 9 10 3. Loudspeaker output terminals 10. Input Socket (phone / balanced) 4. Master Volume control 11. AC fuse holder 5. Output Socket (Phone / balanced) 12. Mains input socket 6. Output Socket (XLR / balanced) 13. Priority switch terminals 7. Output Socket (2X RCA phono) +12V (50mA) SW CHIME ON/OFF CONTROL VCA CHIME SIGNAL +VCC Pre AMP MIC1 MASTER VOX MUTE Pre AMP VOLUME CONTROL +VCC LINK Pre ANP Pre AMP MIC2 MUTE LINE OUT RELAY PRIORITY +VCC SYSTEM CONTROL Pre OUT 100V POWER IN 8OHM Pre AMP COM MIC3 MUTE RECTIFIER +VCC TRANS. FUSE FUSE Pre AMP 115V/230V DC24V MIC4 MUTE 600OHM MOH DRIVER COM 8OHM Pre AMP Pre AMP AUX CD TEL MUTE VOX BUS 6 PA6120 VR STAND ALDNE BALANCED IN MASTER SLAVE Pre AMP SELECT POWER AMP Pre AMP BALANCED OUT RELAY SPEECH ONLY TRANS. 100V 8OHM UNBALANCED IN COM Pre AMP UNBALANCED OUT RECTIFIER TRANS. FUSE FUSE 115V/230V SW CONTROL POIORITY DC24V PAB6120/6240 GND GND 115V~ 230V~ 600 Apparatus delivered Connected for 230v~ PHANTOM LINE MIC 1V 8 1W + MONITOR OUTPUT MUSIC/SPEECH DC 24V + COM 8 100V P ~ 0 ~ PHANTOM LINE MIC TEL/EMER PRE OUT COM 100V LINE FUSE MIC 4 7 MIC 3 SENS VR SENS VR MIC 2 MIC 1 115V~ 230V~ Apparatus delivered Connected for 230v~ OUTPUT INPUT LINE FUSE MASTER VR BALANCED UNBALANCED BALANCED Mains Connection The supply transformer has been designed for use on either 115Vac or 230Vac, selected by slide switch on rear panel. The amplifier is factory set at 230Vac mains voltage. Battery Connection (24Vdc) When using external batteries, earth the amplifier via the screw terminal because of the high voltages present. Electrical stability of the system is increased by earthing the case. NOTE: The connection cable must be fitted with an in-line fuse. quick blow type (30W : 5A, 60W : 8A, 120W : 15A, 240W : 20A, 480W : 40A). When Connecting batteries please ensure correct polarity. Microphone Connection Mic1~4 inputs are balanced standard 1/4” stereo jack, DIN and XLR Socket on the rear panel (With selectable phantom power). Wiring is as follows: XLR (Balanced Operation) Pin1 : Screen 2 Pin2 : Signal (live) 1 3 Pin3 : Signal (return) DIN (Balanced operation) Pin1 : Signal (live) Pin2 : GND Pin3 : Signal (Return) 3 Pin4 : Priority Control 8 1 5 2 4 Pin5 : GND 1/4” Stereo Jack Plug (Balanced operation) Tip : Signal (live) Ring : Signal (Return) Sleeve : Screen Priority Microphone Mic1 input has VOX priority which will override Mic2~4 and Line input signals but NOT the TEL / EMER input. Mic2 input which will override Mic3~4 and Line input signals but NOT the TEL/EMER and Mic1 Inputs. Mic3 input which will override Mic4 and Line input Signals but NOT the TEL/EMER Mic1 and Mic2 Inputs. Mic4 input which will override Line input Signals only but NOT the TEL/EMER Mic1, Mic2, and Mic3 Inputs. Mic3~4 input are (DIN, phone / XLR) with Selectable phantom power located on the rear panel and wire as above. Mic1~2 input are with Selectable phantom power located on the PCB (sw401, sw402) Chime on/off 1. Switching the manual priority terminals on the rear panel will activate the chime function. 2. Depending on the position of the “chime” switch on the rear of the amplifier. switching on Microphone 1~4 (DIN Socket) will activate the chime (Ding-Dong attention signal, preceding a call). The default Volume of the chime is set at 8dB(40V). Which will be Sufficient in most applications. If required the Volume Can be altered by adjusting the potention meter (VR303, Chime) on the main PCB of the unit. Telephone/Emergency Connection The emergency input is for emergency announcements / signals and is not affected by the master volume control. The volume can be setted by the volume control on the rear panel (can not be set to zero). The emergency input has the highest priority, all other inuts will be overruled. Monitor output (MOH) Connection Two monitor outputs are provided on the rear panel. (i) 600 / 1V. to feed an EPABX system. Output level adjustable. Please consult your EPABX handbook to utilise this facility. (ii) 8 , 1W for monitoring applications. Line (Aux/CD) Connection The equipment provides an auxiliary input which may be used for connecting other signal sources such as a Radio Tuner, CD or Cassette player. A slide switch is located on the front panel for selection of, Aux and CD. The line level Control operates on each of the input sources. To operate select the desired music source using the slide switch and turn the “Line” control clockwise to increase the volume or anticlockwise to reduce the volume. The Aux / CD input sockets are standard RCA phono, two sockets are supplied and these are linked together internally, this allows stereo signal source to be used without the need to 9 obtain a special lead, however you may wish to check with the manufacturer of the signal source to ensure that no damage will result if the left and right output channels are put in parallel. RCA Phono plug connections Sleeve- Screen Pin- Signal Tape Output Connection These standard RCA phono sockets provide a mixed output suitable for connection to a tape or Cassette recorder. Power in and pre out Connects the mixer/preamplifier stage to the power amplifier stage. The connecting link must be plugged in for normal operation as a mixer/amplifier. If a compressor/limiter, equalizer, or other external signal processor is used in the sound system, connect the “PRE OUT’ to the input of the external processor and the output of the processor to “POWER IN” In the signal chain, “PRE OUT” is after the tone controls and the master volume control. Loudspeaker Connection Note: Use only 100V or 70V (Selectable) Line Loudspeakers Two loudspeaker outputs are provided. The output marked ‘Music/speech gives an output at all times, reproducing any signal input into the amplifier. The output marked ‘Speech Only’ will only reproduce a signal during a priority condition, therefore an output from this connection will be present when Microphone is in a priority condition. this means that only the ‘Ding Dong’ chime and the signal from one of these microphone inputs will be presented to this output. Low Impedance (8 ) This output allows connection of standard low impedance loudspeakers, the minimum load impedance must be 8 , when two or more loudspeakers are use ensure that they are wired in such a way that the load impedance is between 8 and 16 . Connecting a Mixer Amplifier to a Power Amplifier These amplifier can be connected using phono to phono leads from the mixer amplifier PRE out to the power amplifier input phono socket. further power amplifier Can be connected by connecting from the output of first power amplifier to the input of the second. up to three power amplifier can be connected in this way. If the Two Zone feature is required. the manual priority terminals must be used. connecting the priority terminals from the mixer amplifier to the first power amplifier. up to three power amplifier can be connected in this way. VCA noise gate The mixer amplifier are equipped with a VOX in master section. The input level which is required to open the noise gate (S601 on the VR PCB-fixed on the front panel). When using the noise gate ( on ) then the S/N ratio can get more than 75dB for MIC inputs and 80dB for Aux / CD inputs. 10 Power amplifier setting SW403 100m V 500m V SW404 1V SW401 PAB-1 Input Sensitivity Setting The amplifier has three ( 1V, 500mV, 100mV) Selectable input Sensitivity located on the PCB (SW401). The sensitivity of amplifier are factory Set to 500mV. Amplifier Settings (connecting more power amplifiers) (mode selector switch located on the PCB) (SW403) (SW404) (AMPLIFIER) STAND ALONE MASTER SLAVE Single unit operation For single unit operation, set the mode selector switch (SW403,SW404) Located on the PCB to the “ STAND ALONE” position. Three unit operation For two or three unit operation, one unit must be designated the master unit, this can be done by the mode selector switch to the “ MASTER “ position. All other units must be switched to “SLAVE” mode. Series 6000 Type Model Supply Mains Voltage Battery Voltage Output power Max : Rated : Outputs Inputs Frequency response Total harmonic distortion Signal to noise ratio Tone Controls Controls Indicators AC power consumption DC power consumption Technical Specifications TWO ZONE Mixer Amplifier PA 6030 PA 6060 PA 6120 AC 115V / 230V , 50 / 60Hz ± 10% Switchable DC 24V (MAX 10% diviation) 45W 90W 180W 30W 60W 120W Speaker outputs: Music/speech: 8 ,100V(70V/100V Selectable) Speech: 100V (70V/100V Selectable) Tape output: 350mV 4.7K Pre output: 1V, 600 MoH output: 8 I watt / 600 ,1V balanced. Mic1/2:Sens. Adj (1mV~200mV),250 balanced with phantom power selectable. Mic3/4:Mic - 1mV, 250 ,balanced without phantom power. Phantom - 1mV, 250 ,balanced with phantom power. Line - 100mV, 47K ,balanced without phantom power. CD:500mV,47K ,unbalanced Aux:200mV,47K ,unbalanced TEL : 0.1~1V,600 ,adjustable, balanced Power in:1V,47K ,unbalanced Mic1~Mic4: 60Hz ~ 15KHz ± 3dB Aux/CD : 50Hz ~ 20KHz ± 3dB TEL : 100Hz ~ 15KHz ± 3dB Less than1% at 1KHz,rated power All Volume Controls C.C.W. : 80dB below rated power Mic1 ~ 4 : 60dB below rated power TEL : 70dB below rated power Line (Aux/CD) : 70dB below rated power Bass : ±10 dB at 100Hz Treble: ±10 dB at 10KHz Mic1~Mic4 volume control Line(Aux/CD) volume control Master volume control TEL input level control MOH output level control Tone controls (Bass,Treble) Chime on/off switch Line / phantom / mic selector switch AC 115V / 230V voltage Selector switch Power indicator (LED),output level indicators (5 LEDS) 90 watts 170 watts 360 watts 2A 4A 8A 11 Chime Priority Two tone chime (Ding-done attention signal preceding a call). Priority level (Using for Mic1~4, the 5 pole DIN connector) Tel / Emer Mic1 Mic2 Mic3 Mic4 Aux/CD 6 5 4 3 2 1 Priority level (Using for “priority” screw terminal) Tel / Emer Mic1 Mic2 Mic3 Mic4 Aux/CD 6 2 2 2 2 1 88 ×430 ×300 mm Approx 7.0kg Approx 8.5kg Approx Black Table top or 19” rack mountable Dimentions ( H ×W ×D ) Weight Color Mounting options Series 6000 Supply Output power 10.0kg Technical Specifications Type Model Mains Voltage Battery Voltage Max : Rated : Outputs Inputs Frequency response Total harmonic distortion Signal to noise ratio Controls Indicators AC power consumption DC power consumption Dimentions ( H ×W ×D ) Weight Color Mounting options TWO ZONE Power Amplifier PAB 6120 PAB 6240 PAB6480 AC 115V / 230V , 50 / 60Hz ± 10% switchable AC 230V , 50Hz ± 10% DC 24V (MAX 10% deviation) 180W 360W 720W 120W 240W 480W Speaker outputs: Music/speech: 8 ,100V(70V/100V Selectable) Speech: 100V (70V/100V Selectable) Line output: 1V, 600 Line input : 1V, 47K Line input : 1V, 47K (Balanced & Unbalanced) 50Hz ~ 20KHz ± 3dB Less than 1% at 1KHz,rated power. 80dB below rated power. Master volume control. Master volume control. AC 115V / 230V Voltage selector switch. Power indicator (LED),output level indicators (5 LEDS) 360 watts 760 watts 1500watts 8A 16 A 32 A 88 ×430 ×300 mm 133 x 430 x 365 mm Approx 10.0kg Approx 13.0kg Approx. 25.0kg Black Table top or 19” rack mountable. 12