Puhy-p-ygm-a Databook

   EMBED


Share

Transcript

Y-8˜14(R410A) 2- 3 1. Specifications PUHY-P200YGM-A (-BS) Y-8˜14(R410A) Model name Capacity Cooling Heating *1 kW 22.4 25.0 *1 BTU/h 76,400 85,300 *1 kcal/h 20,000 3N ~ 380/400/415V 50/60Hz Power source Power input Current kW 6.14 5.98 A 10.3 / 9.8 / 9.4 10.0 / 9.5 / 9.2 Propeller fan x 1 Type x Quantity Airflow rate Fan m3/min 200 kW 0.38 Motor output Type Hermetic Compressor Motor output Crankcase heater kW 4.7 kW 0.045 x 1 Salt resistant fin Heat exchanger R410A / MEL56 Refrigerant / Lubricant External finish mm External dimension H x W x D Pre-coated galvanized sheets (+ powder coating for –BS type) 1,840 x 990 x 840 4.15MPa High pressure protection Over current protection / Over heat protection Protection Compressor devices Fan Thermal switch Over current protection / Thermal protection Inverter Refrigerant High press. pipe piping diameter Low press. pipe ø9.52 Flare ø19.05 Brazed 50~130% of outdoor unit capacity Total capacity Indoor unit Model P20~P250 / 1~13 Model / Quantity Noise level *2 56 / 56 dB Net weight kg 218 Cooling Operating temperature range Heating Indoor : 15˚CWB ~ 24˚CWB Outdoor: -5˚CDB ~ 43˚CDB (0˚CDB ~ 43˚CDB, when the outdoor unit is at a lower position) Indoor : 15˚CDB ~ 27˚CDB Outdoor: -20˚CWB ~ 15.5˚CWB Note: *1. Cooling/Heating capacity indicates the maximum value at operation under the following condition. Indoor : 27˚CDB / 19.5˚CWB Outdoor : 35˚CDB Indoor : 27˚CDB / 19˚CWB Outdoor : 35˚CDB Pipe length : 5m Height difference : 0m Indoor : 20˚CDB Outdoor : 7˚CDB / 6˚CWB Pipe length : 7.5m Height difference : 0m *2. It is measured in anechoic room. ** Installation/foundation work, electrical connection work, duct work, insulation work, power source switch, and other items shall be referred to the Installation Manual. Ref.: M-WYNCO-6927&6940 2- 4 PUHY-P250YGM-A (-BS) Model name Heating *1 kW 28.0 31.5 *1 BTU/h 95,500 107,500 *1 kcal/h 25,000 3N ~ 380/400/415V 50/60Hz Power source Power input Current kW 7.72 7.62 A 13.0 / 12.3 / 11.9 12.8 / 12.2 / 11.7 Propeller fan x 1 Type x Quantity Airflow rate Fan m3/min 200 kW 0.38 Motor output Type Hermetic Compressor Motor output Crankcase heater kW 6.7 kW 0.045 x 1 Salt resistant fin Heat exchanger R410A / MEL32 Refrigerant / Lubricant External finish mm External dimension H x W x D Pre-coated galvanized sheets (+ powder coating for –BS type) 1,840 x 990 x 840 4.15MPa High pressure protection Over current protection / Over heat protection Protection Compressor devices Fan Thermal switch Over current protection / Thermal protection Inverter Refrigerant High press. pipe piping diameter Low press. pipe ø9.52 Flare (ø12.7 for over 90m) ø22.2 Brazed 50~130% of outdoor unit capacity Total capacity Indoor unit Model P20~P250 / 1~16 Model / Quantity Noise level Y-8˜14(R410A) Capacity Cooling *2 57 / 57 dB Net weight 233 kg Cooling Operating temperature range Indoor : 15˚CWB ~ 24˚CWB Outdoor: -5˚CDB ~ 43˚CDB (0˚CDB ~ 43˚CDB, when the outdoor unit is at a lower position) Heating Indoor : 15˚CDB ~ 27˚CDB Outdoor: -20˚CWB ~ 15.5˚CWB Note: *1. Cooling/Heating capacity indicates the maximum value at operation under the following condition. Indoor : 27˚CDB / 19.5˚CWB Outdoor : 35˚CDB Indoor : 27˚CDB / 19˚CWB Outdoor : 35˚CDB Pipe length : 5m Height difference : 0m Indoor : 20˚CDB Outdoor : 7˚CDB / 6˚CWB Pipe length : 7.5m Height difference : 0m *2. It is measured in anechoic room. ** Installation/foundation work, electrical connection work, duct work, insulation work, power source switch, and other items shall be referred to the Installation Manual. Ref.: M-WYNCO-6928&6941 2- 5 PUHY-P300YGM-A (-BS) Y-8˜14(R410A) Model name Capacity Cooling Heating *1 kW 33.5 37.5 *1 BTU/h 114,300 127,900 *1 kcal/h 30,000 3N ~ 380/400/415V 50/60Hz Power source Power input Current kW 9.57 9.10 A 16.1 / 15.3 / 14.7 15.3 / 14.5 / 14.0 Propeller fan x 1 Type x Quantity Airflow rate Fan m3/min 200 kW 0.38 Motor output Type Hermetic Compressor Motor output Crankcase heater kW 8.0 kW 0.045 x 1 Salt resistant fin Heat exchanger R410A / MEL32 Refrigerant / Lubricant External finish mm External dimension H x W x D Pre-coated galvanized sheets (+ powder coating for –BS type) 1,840 x 990 x 840 4.15MPa High pressure protection Over current protection / Over heat protection Protection Compressor devices Fan Thermal switch Over current protection / Thermal protection Inverter Refrigerant High press. pipe piping diameter Low press. pipe ø9.52 Flare (ø12.7 for over 40m) ø22.2 Brazed 50~130% of outdoor unit capacity Total capacity Indoor unit Model P20~P250 / 1~19 Model / Quantity Noise level *2 59 / 59 dB Net weight 233 kg Cooling Operating temperature range Heating Indoor : 15˚CWB ~ 24˚CWB Outdoor: -5˚CDB ~ 43˚CDB (0˚CDB ~ 43˚CDB, when the outdoor unit is at a lower position) Indoor : 15˚CDB ~ 27˚CDB Outdoor: -20˚CWB ~ 15.5˚CWB Note: *1. Cooling/Heating capacity indicates the maximum value at operation under the following condition. Indoor : 27˚CDB / 19.5˚CWB Outdoor : 35˚CDB Indoor : 27˚CDB / 19˚CWB Outdoor : 35˚CDB Pipe length : 5m Height difference : 0m Indoor : 20˚CDB Outdoor : 7˚CDB / 6˚CWB Pipe length : 7.5m Height difference : 0m *2. It is measured in anechoic room. ** Installation/foundation work, electrical connection work, duct work, insulation work, power source switch, and other items shall be referred to the Installation Manual. Ref.: M-WYNCO-6929&6942 2- 6 PUHY-P350YGM-A (-BS) Model name Heating *1 kW 40.0 45.0 *1 BTU/h 136,500 153,500 *1 kcal/h 35,000 3N ~ 380/400/415V 50/60Hz Power source Power input Current kW 11.39 11.02 A 19.2 / 18.2 / 17.6 18.6 / 17.6 / 17.0 Propeller fan x 1 Type x Quantity Fan Airflow rate m3/min 200 Motor output kW 0.38 Type Hermetic Compressor Motor output Crankcase heater kW 9.6 kW 0.045 x 1 Salt resistant fin Heat exchanger R410A / MEL32 Refrigerant / Lubricant External finish mm External dimension H x W x D Pre-coated galvanized sheets (+ powder coating for –BS type) 1,840 x 990 x 840 4.15MPa High pressure protection Over current protection / Over heat protection Protection Compressor devices Fan Thermal switch Over current protection / Thermal protection Inverter Refrigerant High press. pipe piping diameter Low press. pipe ø12.7 Flare ø28.58 Brazed 50~130% of outdoor unit capacity Total capacity Indoor unit Model P20~P250 / 1~20 Model / Quantity Noise level Y-8˜14(R410A) Capacity Cooling *2 60 / 60 dB Net weight 233 kg Cooling Operating temperature range Indoor : 15˚CWB ~ 24˚CWB Outdoor: -5˚CDB ~ 43˚CDB (0˚CDB ~ 43˚CDB, when the outdoor unit is at a lower position) Heating Indoor : 15˚CDB ~ 27˚CDB Outdoor: -20˚CWB ~ 15.5˚CWB Note: *1. Cooling/Heating capacity indicates the maximum value at operation under the following condition. Indoor : 27˚CDB / 19.5˚CWB Outdoor : 35˚CDB Indoor : 27˚CDB / 19˚CWB Outdoor : 35˚CDB Pipe length : 5m Height difference : 0m Indoor : 20˚CDB Outdoor : 7˚CDB / 6˚CWB Pipe length : 7.5m Height difference : 0m *2. It is measured in anechoic room. ** Installation/foundation work, electrical connection work, duct work, insulation work, power source switch, and other items shall be referred to the Installation Manual. Ref.: M-WYNCO-6930&6943 2- 7 2- 8 Y-8˜14(R410A) Y-8˜14(R410A) 2- 9 2. Capacity Table 2-1. Correction by temperature • Standard Specifications PUHY-P200YGM PU(H)Y-P250YGM Capacity kW 22.4 28.0 Input kW 6.14 7.72 Capacity at 100% indoor units running 1.4 1.3 1.2 Ratio 24˚CWB 1.1 22˚CWB 1.0 20˚CWB 18˚CWB 0.9 Indoor Temperature(˚CWB) 16˚CWB 0.8 15˚CWB 0.7 0.6 0.5 -5 0 5 10 15 20 25 30 35 40 45 Outdoor Temperature (˚CDB) Power Input at 100% indoor units running 1.4 1.3 24˚CWB 22˚CWB 20˚CWB 18˚CWB 16˚CWB 15˚CWB 1.2 1.1 Ratio Y-8˜14(R410A) Cooling 1.0 Indoor Temperature(˚CWB) 0.9 0.8 0.7 0.6 0.5 -5 0 5 10 15 20 25 30 35 40 45 Outdoor Temperature (˚CDB) Ref: cap&inpc-p200-250 2- 10 Heating PUHY-P200YGM PUHY-P250YGM Capacity kW 25.0 31.5 Input kW 5.98 7.62 Y-8˜14(R410A) • Standard Specifications Capacity at 100% indoor units running 1.3 15˚CDB 1.2 1.1 Ratio 1.0 20˚CDB 0.9 0.8 Indoor Temperature(˚CDB) 25˚CDB 0.7 27˚CDB 0.6 0.5 0.4 -20 -15 -10 -5 0 5 10 15 Outdoor Temperature (˚CWB) Power Input at 100% indoor units running 1.3 1.2 1.1 Indoor Temperature(˚CDB) 15˚CDB Ratio 1.0 0.9 0.8 20˚CDB 0.7 25˚CDB 0.6 27˚CDB 0.5 0.4 -20 -15 -10 -5 0 5 10 15 Outdoor Temperature (˚CWB) Ref: cap&inph-p200-250 2- 11 • Standard Specifications PUHY-P300YGM PU(H)Y-P350YGM Capacity kW 33.5 40.0 Input kW 9.57 11.39 Capacity at 100% indoor units running 1.4 1.3 1.2 Ratio 24˚CWB 1.1 22˚CWB 1.0 20˚CWB 18˚CWB 0.9 Indoor Temperature(˚CWB) 16˚CWB 0.8 15˚CWB 0.7 0.6 0.5 -5 0 5 10 15 20 25 30 35 40 45 Outdoor Temperature (˚CDB) Power Input at 100% indoor units running 1.4 1.3 24˚CWB 22˚CWB 20˚CWB 18˚CWB 16˚CWB 15˚CWB 1.2 1.1 Ratio Y-8˜14(R410A) Cooling 1.0 0.9 Indoor Temperature(˚CWB) 0.8 0.7 0.6 0.5 -5 0 5 10 15 20 25 30 35 40 45 Outdoor Temperature (˚CDB) Ref: cap&inpc-p300-400 2- 12 Heating PUHY-P300YGM PUHY-P350YGM Capacity kW 37.5 45.0 Input kW 9.10 11.02 Y-8˜14(R410A) • Standard Specifications Capacity at 100% indoor units running 1.3 1.2 15˚CDB 1.1 Ratio 1.0 20˚CDB 0.9 0.8 Indoor Temperature(˚CDB) 25˚CDB 0.7 27˚CDB 0.6 0.5 0.4 -20 -15 -10 -5 0 5 10 15 Outdoor Temperature (˚CWB) Power Input at 100% indoor units running 1.3 1.2 1.1 Indoor Temperature(˚CDB) Ratio 1.0 15˚CDB 0.9 0.8 0.7 20˚CDB 0.6 25˚CDB 0.5 0.4 -20 27˚CDB -15 -10 -5 0 5 10 15 Outdoor Temperature (˚CWB) Ref: cap&inph-p300-400 2- 13 2-2. Correction by total indoor PUHY-P200YGM 1) Capacity 30.0 Capacity(kW) 20.0 Cooling 15.0 10.0 5.0 100 150 200 250 300 Total capacity of indoor units Ref: pl-puhy200ygmc 2) Input 7.00 Input(kW) 6.00 Heating 5.00 4.00 Cooling 3.00 2.00 100 150 200 250 300 Ref: pl-puhy200ygmi Total capacity of indoor units PU(H)Y-P250YGM 1) Capacity 35.0 Heating Capacity(kW) 30.0 Cooling 25.0 20.0 15.0 10.0 100 150 200 250 300 350 Total capacity of indoor units 400 Ref: pl-puhy250ygmc 2) Input 8.00 Heating 7.00 Input(kW) Y-8˜14(R410A) Heating 25.0 6.00 Cooling 5.00 4.00 3.00 100 150 200 250 Total capacity of indoor units 2- 14 300 350 400 Ref: pl-puhy250ygmi PUHY-P300YGM 1) Capacity 40.0 Y-8˜14(R410A) Capacity(kW) 35.0 Cooling Heating 30.0 25.0 20.0 15.0 100 150 200 250 300 Total capacity of indoor units 350 400 450 Ref: pl-puhy300ygmc 2) Input 10.00 9.00 Input(kW) 8.00 Heating 7.00 6.00 Cooling 5.00 4.00 3.00 100 150 200 250 300 350 400 450 Ref: pl-puhy300ygmi Total capacity of indoor units PU(H)Y-P350YGM 1) Capacity 50.0 45.0 Capacity(kW) 40.0 Cooling Heating 35.0 30.0 25.0 20.0 15.0 10.0 100 150 200 250 300 350 400 Total capacity of indoor units 450 500 550 Ref: pl-puhy350ygmc 2) Input 12.00 11.00 Capacity(kW) 10.00 9.00 Heating 8.00 7.00 6.00 Cooling 5.00 4.00 100 150 200 250 300 350 Total capacity of indoor units 2- 15 400 450 500 550 Ref: pl-puhy350ygmi 2-3. Correction by refrigerant piping length Y-8˜14(R410A) Due to the extension of refrigerant piping, a decrease of cooling/heating capacity happens. The actual capacity is considered by multiplying the correction factor according to the equivalent length of the refrigerant piping shown at the table below. 2- 16 2-4. Correction at frosting and defrosting Due to frosting at the outdoor heat exchanger and the automatical defrosting operation, the heating capacity of the outdoor unit should be considered by multiplying the correction factor which shown in the table below. PU(H)Y-P200, 250YGM Outdoor inlet air temp (ßCWB) Correction factor 6 4 2 1 0 -2 -4 -6 -8 -10 -20 1.0 0.95 0.84 0.83 0.83 0.87 0.90 0.95 0.95 0.95 0.95 Ref.: def-ygmp200-250 PUHY-P300YGM Outdoor inlet air temp (ßCWB) Correction factor 6 4 2 1 0 -2 -4 -6 -8 -10 -20 1.0 0.93 0.82 0.80 0.82 0.86 0.90 0.90 0.95 0.95 0.95 Ref.: def-ygmp300 PU(H)Y-P350YGM Outdoor inlet air temp (ßCWB) Correction factor 6 4 2 1 0 -2 -4 -6 -8 -10 -20 1.0 0.93 0.85 0.83 0.84 0.86 0.90 0.90 0.95 0.95 0.95 Ref.: def-ygmp350 2- 17 Y-8˜14(R410A) Table of correction factor 2-5. Operation limit • Cooling Y-8˜14(R410A) Indoor temperature (˚CWB) 30 25 20 15 10 5 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 Outdoor temperature (˚CDB) * The operation temperature of outdoor unit is limited into 0~43˚CDB when the outdoor unit is at a postion lower than the indoor units. • Heating Indoor temperature (˚CDB) 30 25 20 15 10 5 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 30 35 40 45 50 Outdoor temperature (˚CWB) • Cooling Indoor temperature (˚CWB) 30 25 20 15 10 5 -20 -15 -10 -5 0 5 10 15 20 25 Outdoor temperature (˚CDB) Ref.: ol-ygmc * The operation temperature of outdoor unit is limited into 0~43˚CDB when the outdoor unit is at a postion lower than the indoor units. 2- 18 3. Sound Levels PUHY-P200YGM Measurement condition 250Hz 62 58 56 dB(A) 500Hz 1000Hz 2000Hz 4000Hz 8000Hz 52.5 49.5 50 41.5 38 56 90 OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20 Pa 1m Measurement location 125Hz 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 20 10 Y-8˜14(R410A) 1m 63Hz NC-30 Approximate minimum audible limit on continuous noise 63 125 250 NC-20 500 1000 2000 4000 8000 OCTAVE BAND CENTER FREQUENCIES (Hz) Ref.: h200ygm-WYNB0-3270 PU(H)Y-P250YGM Measurement condition 125Hz 250Hz 58.5 55.5 dB(A) 500Hz 1000Hz 2000Hz 4000Hz 8000Hz 53 49.5 49 49 43 57 90 OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20 Pa Measurement location 1m 1m 63Hz 62.5 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 Approximate minimum audible limit on continuous noise 63 125 250 NC-20 500 1000 2000 4000 8000 OCTAVE BAND CENTER FREQUENCIES (Hz) Ref.: h250ygm-WYNB0-3271 2- 19 PUHY-P300YGM Measurement location 1m 1m 125Hz 250Hz 65 61 58 500Hz 1000Hz 2000Hz 4000Hz 8000Hz 55 51.5 51 51 45.5 dB(A) 59 90 OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20 Pa Y-8˜14(R410A) Measurement condition 63Hz 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 Approximate minimum audible limit on continuous noise 63 125 250 NC-20 500 1000 2000 4000 8000 OCTAVE BAND CENTER FREQUENCIES (Hz) Ref.: h300ygm-WYNB0-3272 PU(H)Y-P350YGM Measurement condition 125Hz 250Hz 63 64 57.5 500Hz 1000Hz 2000Hz 4000Hz 8000Hz 55 50.5 50.5 54 dB(A) 50 60 90 OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20 Pa Measurement location 1m 1m 63Hz 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 Approximate minimum audible limit on continuous noise 63 125 250 NC-20 500 1000 2000 4000 8000 OCTAVE BAND CENTER FREQUENCIES (Hz) Ref.: h350ygm-WYNB0-3274 2- 20 A 80 A 132 136 136 146 12 5 Note1.Use the opening at the bottom of the unit when running the power supply line from the front or from the side of the unit. Note2.Please refer to the next page for information regarding necessary spacing around the unit and foundation work. Ref: ygm-W656818 1/2 80 –Y 20 70 553 117 Left side view Air outlet 117 80 135 Service panel 100 Refrig. service valve (Liquid) X Refrig. service valve(Gas) 37 Knockout hole 40 45 Knockout hole 2X2-14X20 0val hole (Mounting hole) ø27 Knockout hole Air inlet ø62 Knockout hole Changeable to ø27,ø33 by using attached conduit mounting plate 37 Air inlet Cross section X – X Cross section Y • Refrigerant (Gas) conn. pipe......1 pc. (P200type:Packaged in the accessory kit) (P250,P300,P350type:Already installed on the unit) • Packing for conn. pipe................1 pc. (P200type:Not attached) (P250,P300,P350type:Attached near the ball valve) • Conduit mounting plate ø33, ø27..............................1 pc.Each • Tapping screw M4......................2 pcs. Model 200 250 300 350 166 Knockout hole 768 ø53 57 Conn. pipe(Liquid) 200: ø9.52 250: ø9.52 300: ø9.52 350: ø12.7 65 160 280 Y 134 100 67 207 83 67 160 Front view Knockout hole Top view 990 900(mounting pitch) 207 67 840 X 45 877 1840 ø27 Knockout hole 235 Conn. pipe(Gas) 200: ø19.05 250: ø22.2 300: ø22.2 350: ø28.58 10 90 44 150 2- 21 11 78 16 845(mounting pitch) 16 265 1575 Y PU(H)Y-P200,250,300,350YGM-A(-BS) Y-8˜14(R410A) 494 4. External Dimensions Unit : mm 2- 22 A B B A Ref: ygm-W656818 1/2 1000 Wall height 450 A 450 A A Wall height A Wall height M10 Anchor Bolt Corner No restrictions on wall height A A Wall height B ❈ B ❈ 1000 450 ❈ A 450 A 450 A B A Wall height Wall height B B 1000 450 A 1Space required for collective installation and continuous installation: When installing several units, provide the space between each block considering passage for air and people. 2Open in two directions. 3In case of wall height exceeds total height of unit, add dimension (h= wall height - total height of unit) to ❈ marked dimension. 4If there is a wall at both the front and the rear of the unit, install up to four units consecutively in the side direction and provide a space of 1000 mm or more as inlet space/passage space for each four units. ✻ In case of collective installation and continuous installation 1When building the foundation, give full attention to the floor strength, drain water disposal , piping and wiring routes. 2Be sure that the corners are firmly seated. If the corners are not firmly seated, the installation feet may be bent. 3When down piping and down wiring are performed, be sure that foundation and base work does not block the base through holes. 2.Foundation work No restrictions on wall height A H H' 1Wall heights of the front and the back sides shall be within total height of unit. 2When wall height exceeds total height of unit, add dimension to 450 of the following figure. h= wall height - total height of unit. 450 450 [When inlet air enters from right and left sides of unit] Front 450 450 1Since the service from the back of unit is required, provide the back space 450 mm or above as the front. ✻ In case of single installation [Basic rules for spacing the unit] 450 450 h H 450 1.Space required around unit 450 A A B (Unit : mm) B Must be open A Front 450 ❈ Wall height 450 900 450 450 900 450 Y-8˜14(R410A) Spacing of PU(H)Y-P200,250,300,350YGM-A(-BS) 2- 23 PE 60A PUHY-P400YGM-A blue Ref: Y-p200~400ygm-W274627 40A PU(H)Y-P350YGM-A PU(H)Y-P200,P250,P300YGM-A 30A N L3 black L3 N L2 white L2 M2 M1 TB3 M1 S M2 TB7 L1 Breakers for wiring Breakers for current leakage 50/60Hz 380/400/415V Power source 3N~ shield shield 21S 4b ✻4 SV 5b TB1 (Terminal Block) L1 red INDOOR/ OUTDOOR TRANSMISSION LINE CENTRAL CONTROL TRANSMISSION LINE CH11 21S 4a ✻5 21S 4c SV 5c SV1 63H1 52 C1 CN20 45 CN21 1 2 3 blue 123 X01 X02 X03 X06 X07 X08 X09 F01 250VAC 6.3A T detection circuit detection circuit detection circuit 21 3 2 1 CNL black 21 LD1 1 1 1 Unit address setting ~ + ~ ~ - 1 2 3 CNS2 blue black ZNR14 1 2 CNS1 blue C15 52C1 R11 R12 Refer to the service handbook about the switch operations. SWU3 SWU2 SWU1 ✻1 10 10 10 10 SW5 SW4 SW3 SW2 SW1 2 1 0 10 1 3 2 1 R23 CNH CNTYP4 CNTYP5 3 2 1 R22 Control circuit board (MAIN BOARD) CN01 1 2 3 63HS 1 2 3 63LS OFF ON OFF ON OFF ON OFF ON OFF ON 1 DS1 (Diode stack) red X11 CN02 8 7 6 5 4 3 2 1 CNTYP1 red 21 TH8 TH7 TH6 TH5 TH11 F02 250VAC 6.3A T ACNF1 (Noise Filter) red L1 white L2 black L3 blue N E 1 CN32 2 3 1 CN33 2 3 4 5 6 1 CN36 2 3 4 5 6 7 8 9 1 2 CN35 3 red 1 2 CN38 3 green 3 CN52C 1 yellow 2 X52 Inverter controller box Z20 red white black DCL1 CNLVB red 123456 LEV1 C12 C11 1 1 2 3 + + R14 R13 5 6 7 8 1 2 3 CNVCC1 4 1 2 3 CNRS3B 4 5 6 7 CNAC3 2 3 black 1 5 6 7 CNRS3A 4 12V CN51 1 CN3N 3 blue 2 CN3S 3 2 red 1 3 CN3D 2 5 4 3 2 1 DCCT1 1234 ✻3 black red C14 T01 (Transfomer) Trouble Compressor ON/OFF N P ✻1 or STEP DEMAND 4 3 2 1 ACCT-U IPM1 ON OFF U V 12 12 L2 CNL2 CNFG blue 1 2 3 4 5 6 7 8 14 1 14 9 9 1 1 CN15V2 CNDR2 1 2 3 CNDC2 4 black 1 2 3 4 1 SW1 ON 4 SW2 1 CNCT OFF 1 2 CNTH green THHS1 1 2 3 4 6 LED1 operation LED2 error F01 250VAC 2A T 1 12345 OFF ON Power circuit board 1 (INV BOARD) CNVCC1 12345678 CNAC2 F02 700VDC 2A T 4 3 CNCT2 2 blue 1 L1 12 CNL1 1 FILTER 2 3 BOARD 4 5 6 7 CNOUT CNIN blue 8 green CNDC1 black CNDR1 W white black ACCT-W SW2 red CNVDC ACCT1 123 4 6 5 4 3 2 1 Gate amp board 1 (G/A BOARD) CN15V1 CNDC2 1 2 CNTR 3 1 LED1 operation LED2 error FAN control board (FAN BOARD) CNINV 1 2 3 4 5 CNRS2 6 7 ✻2 ) AUTO CHANGEOVER HEAT/COOL SNOW Compressor ON/OFF NIGHT MODE 2 1 CNFAN X01 red 3 CNFG 1 blue 2 CNRS1 1234567 MF3 2 3 2 3 U V W MF W MC1 U Motor (Compressor) V Fan motor (Heat exchanger) 1 CN04 1 Fan motor (Radiator panel) ✻4 ✻4 Earth terminal Function device Choke coil (Transmission) Low pressure sensor High pressure sensor High pressure switch Radiator panel temp. detect bypass outlet temp.detect at Sub-cool coil liquid outlet temp.detect at Sub-cool coil OA temp.detect Pipe temp.detect (Hex outlet) Discharge pipe temp. detect Electronic expansion valve (SC coil) Solenoid valve (Heat exchanger capacity control) Solenoid valve (Discharge-suction bypass) ✻5 4-way valve Appliance “✻3” and “✻4” do not exsist. All exists “✻2”,“✻3”,“✻4” and “✻5” do not exsist. OFF ON ON/OFF Compressor MODE OFF 1-2P OPEN SHORT ON NIGHT CN3D SHORT 75% 50% OPEN 100% 0% Auto changeover:OFF NOTE:The broken lines indicate field wiring. HEAT COOL CN3N 1-2P OPEN SHORT SHORT Auto changeover:ON OPEN CN3N 1-3P ✻2:Auto changeover (CN3N 1-2P,1-3P) OPEN SHORT CN3D 1-2P CN3D 1-3P SW4-7:ON (STEP DEMAND) SHORT OPEN 1-3P CN3D ✻1: Function according to switch operation. (SW4-7,CN3D 1-2P,and CN3D 1-3P) SW4-7:OFF (Compressor ON/OFF and NIGHT MODE) PUY-P250,P300,P350YGM-A “✻2”,“✻4” and “✻5” do not exsist. PUY-P200YGM-A PUHY-P400YGM-A PUHY-P250,P300,P350YGM-A “✻4” do not exsist. PUHY-P200YGM-A Model name < Difference of appliance > Z20 L1,L2 63LS 63HS 63H1 THHS1 TH8 TH7 TH6 TH5 TH11 LEV1 SV5c SV5b SV1 21S4c 21S4b 21S4a Crank case heater (Compressor) Magnetic contactor (Inverter main circuit) MF1 CH11 DC reactor (Power factor improvement) 52C1 ✻3 DC Current Sensor DCL1 DCCT1 Name AC Current Sensor Symbol ACCT1 Thermistor Y-8˜14(R410A) red white black < Symbol explanation > 5. Electrical Wiring Diagram PU(H)Y-P200, 250, 300, 350YGM-A(-BS) 2- 24 Ref: rcd-200~350ygmhp TH6 HEX F SV5b TH5 HEX B TH8 SCC 21S4b TH11 CJ1 63H LEV1 CP2 ST3 63HS COMP O/S 21S4a ST8 ST4 CP1 SV1 Drier TH7 ST7 ST6 ACC ST2 63LS CJ2 ST1 Y-8˜14(R410A) BV2 BV1 6. Refrigerant Circuit Diagram And Thermal Sensor PUHY-P200, 250, 300, 350YGM-A(-BS) 2- 25 SV5b Ref:rcd-200~350ygmco TH6 HEX F TH5 HEX B TH8 SCC TH11 CJ1 63H LEV1 CP2 ST3 COMP O/S 63HS ST8 ST4 CP1 SV1 Drier TH7 ST7 ST6 ACC ST2 63LS CJ2 Y-8˜14(R410A) 21S4b BV2 ST1 BV1 PUY-P250, 350YGM-A(-BS) 2- 26 Y-8˜14(R410A) Y-16(R410A) 2- 27 1. Specifications PUHY-P400YGM-A (-BS) Model name Capacity Cooling Heating *1 kW 45.0 50.0 *1 BTU/h 153,500 170,500 *1 kcal/h 40,000 3N ~ 380/400/415V 50/60Hz Power source Y-16(R410A) Power input Current kW 13.42 12.43 A 22.6 / 21.5 / 20.7 20.9 / 19.9 / 19.2 Propeller fan x 1 Type x Quantity Airflow rate Fan m3/min 240 kW 0.64 Motor output Type Hermetic Compressor Motor output Crankcase heater kW 9.7 kW 0.045 x 1 Salt resistant fin Heat exchanger R410A / MEL32 Refrigerant / Lubricant External finish mm External dimension H x W x D Pre-coated galvanized sheets (+ powder coating for –BS type) 1,840 x 1,290 x 840 4.15MPa High pressure protection Over current protection / Over heat protection Protection Compressor devices Fan Thermal switch Over current protection / Thermal protection Inverter Refrigerant High press. pipe piping diameter Low press. pipe ø12.7 Flare ø28.58 Brazed 50~130% of outdoor unit capacity Total capacity Indoor unit Model P20~P250 / 1~22 Model / Quantity Noise level *2 61 / 61 dB Net weight 275 kg Cooling Operating temperature range Heating Indoor : 15˚CWB ~ 24˚CWB Outdoor: -5˚CDB ~ 43˚CDB (0˚CDB ~ 43˚CDB, when the outdoor unit is at a lower position) Indoor : 15˚CDB ~ 27˚CDB Outdoor: -20˚CWB ~ 15.5˚CWB Note: *1. Cooling/Heating capacity indicates the maximum value at operation under the following condition. Indoor : 27˚CDB / 19.5˚CWB Outdoor : 35˚CDB Indoor : 27˚CDB / 19˚CWB Outdoor : 35˚CDB Pipe length : 5m Height difference : 0m Indoor : 20˚CDB Outdoor : 7˚CDB / 6˚CWB Pipe length : 7.5m Height difference : 0m *2. It is measured in anechoic room. ** Installation/foundation work, electrical connection work, duct work, insulation work, power source switch, and other items shall be referred to the Installation Manual. Ref.: M-WYNCO-6931&6944 2- 28 2. Capacity Table Cooling • Standard Specifications PUHY-P400YGM Capacity kW 45.0 Input kW 13.42 Y-16(R410A) Capacity at 100% indoor units running 1.4 1.3 1.2 Ratio 24˚CWB 1.1 22˚CWB 1.0 20˚CWB 18˚CWB 0.9 Indoor Temperature(˚CWB) 16˚CWB 0.8 15˚CWB 0.7 0.6 0.5 -5 0 5 10 15 20 25 30 35 40 45 Outdoor Temperature (˚CDB) Power Input at 100% indoor units running 1.4 1.3 24˚CWB 22˚CWB 20˚CWB 18˚CWB 16˚CWB 15˚CWB 1.2 Ratio 1.1 1.0 0.9 Indoor Temperature(˚CWB) 0.8 0.7 0.6 0.5 -5 0 5 10 15 20 25 30 35 40 45 Outdoor Temperature (˚CDB) Ref: cap&inpc-p300-400 2- 29 Heating • Standard Specifications PUHY-P400YGM kW 50.0 Input kW 12.43 Y-16(R410A) Capacity Capacity at 100% indoor units running 1.3 1.2 15˚CDB 1.1 Ratio 1.0 20˚CDB 0.9 0.8 Indoor Temperature(˚CDB) 25˚CDB 0.7 27˚CDB 0.6 0.5 0.4 -20 -15 -10 -5 0 5 10 15 Outdoor Temperature (˚CWB) Power Input at 100% indoor units running 1.3 1.2 1.1 Indoor Temperature(˚CDB) Ratio 1.0 15˚CDB 0.9 0.8 0.7 20˚CDB 0.6 25˚CDB 0.5 0.4 -20 27˚CDB -15 -10 -5 0 5 10 15 Outdoor Temperature (˚CWB) Ref: cap&inph-p300-400 2- 30 2-2. Correction by total indoor PUHY-P400YGM 1) Capacity 55.0 Capacity(kW) 50.0 45.0 Heating 40.0 Cooling 35.0 30.0 20.0 150 200 250 300 350 400 450 Total capacity of indoor units 500 Capacity(kW) 600 Ref: pl-puhy400ygmc 2) Input 15.00 14.00 13.00 12.00 11.00 10.00 9.00 8.00 7.00 6.00 5.00 550 Heating Cooling 150 200 250 300 350 400 Total capacity of indoor units 2- 31 450 500 550 600 Ref: pl-puhy400ygmi Y-16(R410A) 25.0 2-3. Correction by refrigerant piping length Y-16(R410A) Due to the extension of refrigerant piping, a decrease of cooling/heating capacity happens. The actual capacity is considered by multiplying the correction factor according to the equivalent length of the refrigerant piping shown at the table below. 2- 32 2-4. Correction at frosting and defrosting Due to frosting at the outdoor heat exchanger and the automatical defrosting operation, the heating capacity of the outdoor unit should be considered by multiplying the correction factor which shown in the table below. Table of correction factor 6 4 2 1 0 -2 -4 -6 -8 -10 -20 1.0 0.95 0.90 0.87 0.88 0.89 0.90 0.95 0.95 0.95 0.95 Outdoor inlet air temp (˚CWB) Correction factor Ref.: def-ygmp400 Y-16(R410A) 2-5. Operation limit • Cooling Indoor temperature (˚CWB) 30 25 20 15 10 5 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 Outdoor temperature (˚CDB) * The operation temperature of outdoor unit is limited into 0~43˚CDB when the outdoor unit is at a postion lower than the indoor units. • Heating Indoor temperature (˚CDB) 30 25 20 15 10 5 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 Outdoor temperature (˚CWB) Ref.: ol-ygmhp 2- 33 3. Sound Levels PUHY-P400YGM 63Hz 67.5 Measurement condition 250Hz dB(A) 500Hz 1000Hz 2000Hz 4000Hz 8000Hz 68.5 60.05 58.5 54.5 50.5 48.5 43 61 90 OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20µPa Measurement location 1m Y-16(R410A) 1m 125Hz 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 Approximate minimum audible limit on continuous noise 63 125 250 NC-20 500 1000 2000 4000 8000 OCTAVE BAND CENTER FREQUENCIES (Hz) Ref.: h400ygm-WYNB0-3275 2- 34 145 5 Ref: ygm-W656819 1/2 Note1.Use the opening at the bottom of the unit when running the power supply line from the front or from the side of the unit. Note2.Please refer to the next page for information regarding necessary spacing around the unit and foundation work. • Refrigerant (Gas) conn. pipe......1 pc. (Already installed on the unit) • Packing for conn. pipe................1 pc. (Attached near the ball valve) • Conduit mounting plate ø53, ø46.............................1 pc.Each • Tapping screw M4.....................2 pcs. Cross section Y – Y 12 166 Conn. pipe(Liquid) ø12.7 503 37 115 Left side view Air outlet 115 80 135 Knockout hole 37 40 45 Refrig. service valve(Gas) 100 Refrig. service valve (Liquid) X Service panel Knockout hole 2X2-14X20 Oval hole (Mounting hole) ø27 Knockout hole Air inlet 80 ø62 Knockout hole to ø46,ø53 by using X Changeable attached conduit mounting plate Air inlet Cross section X – 20 70 80 57 Conn. pipe(Gas) ø28.58 1068 89 65 160 Y 134 100 Knockout hole 280 ø53 ø27 Knockout hole 235 68 83 355 67 160 Front view Knockout hole Top view 1290 1200(mounting pitch) 355 68 X 45 877 1840 Y 44 150 840 11 78 16 845(mounting pitch) 16 265 1575 2- 35 10 PUHY-P400YGM-A(-BS) Y-16(R410A) 644 4. External Dimensions Unit : mm A 450 450 2- 36 B B A Ref: ygm-W656819 2/2 1000 Wall height 1000 A 450 A 450 No restrictions on wall height A A Wall height M10 Anchor Bolt Corner Wall height A Wall height A B ❈ B ❈ 1000 450 ❈ A 450 A B A Wall height Wall height 450 A 450 A 1000 B B 1Space required for collective installation and continuous installation: When installing several units, provide the space between each block considering passage for air and people. 2Open in two directions. 3In case of wall height exceeds total height of unit, add dimension (h=wall height -total height of unit) to ❈ marked dimension. 4If there is a wall at both the front and the rear of the unit, install up to four units consecutively in the side direction and provide a space of 1000 mm or more as inlet space/passage space for each four units. ✻ In case of collective installation and continuous installation 1When building the foundation, give full attention to the floor strength, drain water disposal , piping and wiring routes. 2Be sure that the corners are firmly seated. If the corners are not firmly seated, the installation feet may be bent. 3When down piping and down wiring are performed, be sure that foundation and base work does not block the base through holes. 2.Foundation work No restrictions on wall height A H H' 1Wall heights of the front and the back sides shall be within total height of unit. 2When wall height exceeds total height of unit, add dimension to 450 of the following figure. h=wall height -total height of unit. 450 450 [When inlet air enters from right and left sides of unit] Front 1Since the service from the back of unit is required, provide the back space 450 mm or above as the front. ✻ In case of single installation [Basic rules for spacing the unit] 1.Space required around unit 450 450 h H 450 450 450 900 450 450 A A B (Unit : mm) B Must be open A Front 450 ❈ Wall height 450 900 Y-16(R410A) Spacing of PUHY-P400YGM-A(-BS) 2- 37 M1 S M2 TB7 PE 60A PUHY-P400YGM-A blue Ref: Y-p200~400ygm-W274627 40A PU(H)Y-P350YGM-A PU(H)Y-P200,P250,P300YGM-A 30A N L3 black L3 N L2 white L2 M2 M1 TB3 L1 Breakers for wiring Breakers for current leakage 50/60Hz 380/400/415V Power source 3N~ shield shield 21S 4b ✻4 SV 5b TB1 (Terminal Block) L1 red INDOOR/ OUTDOOR TRANSMISSION LINE CENTRAL CONTROL TRANSMISSION LINE CH11 21S 4a ✻5 21S 4c SV 5c SV1 63H1 52 C1 CN20 45 CN21 1 2 3 blue 123 X01 X02 X03 X06 X07 X08 X09 F01 250VAC 6.3A T detection circuit detection circuit detection circuit CNL black 3 2 1 21 LD1 1 1 1 Unit address setting ~ + ~ ~ - 1 2 3 CNS2 blue black ZNR14 1 2 CNS1 blue C15 52C1 R11 R12 Refer to the service handbook about the switch operations. SWU3 SWU2 SWU1 ✻1 10 10 10 10 SW5 SW4 SW3 SW2 SW1 2 1 0 10 1 3 2 1 R23 CNH CNTYP4 CNTYP5 3 2 1 R22 Control circuit board (MAIN BOARD) CN01 21 1 2 3 63HS 1 2 3 63LS OFF ON OFF ON OFF ON OFF ON OFF ON 1 DS1 (Diode stack) red X11 CN02 8 7 6 5 4 3 2 1 CNTYP1 red 21 F02 250VAC 6.3A T ACNF1 (Noise Filter) red L1 white L2 black L3 blue N E 1 CN32 2 3 1 CN33 2 3 4 5 6 1 CN36 2 3 4 5 6 7 8 9 1 2 CN35 3 red 1 2 CN38 3 green 3 CN52C 1 yellow 2 X52 Inverter controller box TH8 TH7 TH6 TH5 TH11 red white black DCL1 CNLVB red 123456 LEV1 C12 C11 1 1 2 3 + + R14 R13 5 6 7 8 1 2 3 CNVCC1 4 1 2 3 CNRS3B 4 5 6 7 CNAC3 2 3 black 1 5 6 7 CNRS3A 4 12V CN51 1 CN3N 3 blue 2 CN3S 3 2 red 3 CN3D 2 1 5 4 3 2 1 DCCT1 1234 ✻3 black red C14 T01 (Transfomer) Trouble Compressor ON/OFF N P ✻1 or STEP DEMAND 4 3 2 1 ACCT-U IPM1 ON OFF U V 12 12 L2 CNL2 CNFG blue 1 2 3 4 5 6 7 8 14 1 14 9 1 CN15V2 CNDR2 1 9 1 2 3 CNDC2 4 black 1 2 3 4 1 SW1 ON 4 SW2 1 CNCT OFF 1 2 CNTH green THHS1 1 2 3 4 6 LED1 operation LED2 error F01 250VAC 2A T 1 12345 OFF ON Power circuit board 1 (INV BOARD) CNVCC1 12345678 CNAC2 F02 700VDC 2A T 4 3 CNCT2 2 blue 1 L1 12 CNL1 1 FILTER 2 3 BOARD 4 5 6 7 CNOUT CNIN blue 8 green CNDC1 black CNDR1 W white black ACCT-W SW2 red CNVDC ACCT1 123 4 6 5 4 3 2 1 Gate amp board 1 (G/A BOARD) CN15V1 CNDC2 1 2 CNTR 3 1 LED1 operation LED2 error FAN control board (FAN BOARD) CNINV 1 2 3 4 5 CNRS2 6 7 ✻2 ) AUTO CHANGEOVER HEAT/COOL SNOW Compressor ON/OFF NIGHT MODE 2 1 CNFAN X01 red 3 CNFG 1 blue 2 CNRS1 1234567 MF3 2 3 2 3 U V W MF W MC1 U Motor (Compressor) V Fan motor (Heat exchanger) 1 CN04 1 Fan motor (Radiator panel) Function device Appliance “✻3” and “✻4” do not exsist. PUY-P200YGM-A 1-2P ON/OFF ON OFF 1-3P OPEN SHORT SHORT 75% 50% 100% 0% NOTE:The broken lines indicate field wiring. HEAT COOL CN3N 1-2P OPEN SHORT Auto changeover:OFF SHORT Auto changeover:ON OPEN CN3N 1-3P ✻2:Auto changeover (CN3N 1-2P,1-3P) OPEN SHORT OPEN SW4-7:ON (STEP DEMAND) CN3D 1-2P CN3D 1-3P OFF MODE NIGHT SHORT ON OPEN CN3D Compressor CN3D ✻1: Function according to switch operation. (SW4-7,CN3D 1-2P,and CN3D 1-3P) SW4-7:OFF (Compressor ON/OFF and NIGHT MODE) PUY-P250,P300,P350YGM-A “✻2”,“✻4” and “✻5” do not exsist. All exists “✻2”,“✻3”,“✻4” and “✻5” do not exsist. PUHY-P400YGM-A PUHY-P250,P300,P350YGM-A “✻4” do not exsist. PUHY-P200YGM-A Model name < Difference of appliance > Earth terminal Choke coil (Transmission) Low pressure sensor High pressure sensor High pressure switch Radiator panel temp. detect bypass outlet temp.detect at Sub-cool coil liquid outlet temp.detect at Sub-cool coil OA temp.detect Pipe temp.detect (Hex outlet) Discharge pipe temp. detect Electronic expansion valve (SC coil) Solenoid valve (Heat exchanger capacity control) Solenoid valve (Discharge-suction bypass) Z20 ✻4 ✻4 ✻5 4-way valve L1,L2 63LS 63HS 63H1 THHS1 TH8 TH7 TH6 TH5 TH11 LEV1 SV5c SV5b SV1 21S4c 21S4b 21S4a Crank case heater (Compressor) Magnetic contactor (Inverter main circuit) MF1 CH11 DC reactor (Power factor improvement) 52C1 ✻3 DC Current Sensor DCL1 DCCT1 Name AC Current Sensor Symbol ACCT1 Thermistor Z20 Y-16(R410A) red white black < Symbol explanation > 5. Electrical Wiring Diagram PUHY-P400YGM-A(-BS) 2- 38 Ref: rcd-400ygmhp HEX F2 TH6 SV5b SV5c 21S4c HEX F1 TH5 HEX B 21S4b TH8 SCC ST6 CP3 COMP TH11 O/S LEV1 CJ1 63H 63HS 21S4a CP1 ST9 ST8 CJ2 Drier SV1 TH7 ST11 ACC ST10 Y-16(R410A) 63LS ST2 ST1 BV2 BV1 6. Refrigerant Circuit Diagram And Thermal Sensor PUHY-P400YGM-A(-BS) Y-20˜26(R410A) 2- 39 1. Specifications PUHY-P500YGM-A (-BS) Model name Capacity Cooling Heating *1 kW 56.0 63.0 *1 BTU/h 191,100 215,000 *1 kcal/h 50,000 3N ~ 380/400/415V 50/60Hz Power source Power input Current kW 15.59 15.89 A 26.3 / 25.0 / 24.0 26.8 / 25.4 / 24.5 Propeller fan x 2 Type x Quantity Airflow rate Fan m3/min 400 kW 0.38 x 2 Y-20˜26(R410A) Motor output Type Hermetic Compressor Motor output Crankcase heater kW 8.2 + 5.3 kW 0.045 x 2 Salt resistant fin Heat exchanger R410A / MEL32 Refrigerant / Lubricant External finish mm External dimension H x W x D Pre-coated galvanized sheets (+ powder coating for –BS type) 1,840 x 1,990 x 840 4.15MPa High pressure protection Over current protection / Over heat protection Protection Compressor devices Fan Thermal switch Over current protection / Thermal protection Inverter Refrigerant High press. pipe piping diameter Low press. pipe ø15.88 Flare ø28.58 Brazed 50~130% of outdoor unit capacity Total capacity Indoor unit Model P20~P250 / 1~24 Model / Quantity Noise level *2 60 / 61 dB Net weight 455 kg Cooling Operating temperature range Indoor : 15˚CWB ~ 24˚CWB Outdoor: -5˚CDB ~ 43˚CDB (0˚CDB ~ 43˚CDB, when the outdoor unit is at a lower position) Heating Indoor : 15˚CDB ~ 27˚CDB Outdoor: -20˚CWB ~ 15.5˚CWB Note: *1. Cooling/Heating capacity indicates the maximum value at operation under the following condition. Indoor : 27˚CDB / 19.5˚CWB Outdoor : 35˚CDB Indoor : 27˚CDB / 19˚CWB Outdoor : 35˚CDB Pipe length : 5m Height difference : 0m Indoor : 20˚CDB Outdoor : 7˚CDB / 6˚CWB Pipe length : 7.5m Height difference : 0m *2. It is measured in anechoic room. ** Installation/foundation work, electrical connection work, duct work, insulation work, power source switch, and other items shall be referred to the Installation Manual. Ref.: M-WYNCO-6933&6946 2- 40 PUHY-P650YGM-A (-BS) Model name Capacity Cooling Heating *1 kW 73.0 81.5 *1 BTU/h 249,000 278,000 *1 kcal/h 65,000 3N ~ 380/400/415V 50/60Hz Power source Power input Current kW 19.65 19.82 A 33.1 / 31.5 / 30.3 33.4 / 31.7 / 30.6 Propeller fan x 2 Type x Quantity Airflow rate Fan m3/min 400 kW 0.38 x 2 Motor output Type Compressor Motor output Crankcase heater kW 10.9 + 5.3 kW 0.045 x 2 Salt resistant fin Heat exchanger R410A / MEL32 Refrigerant / Lubricant External finish mm External dimension H x W x D Pre-coated galvanized sheets (+ powder coating for –BS type) 1,840 x 1,990 x 840 4.15MPa High pressure protection Over current protection / Over heat protection Protection Compressor devices Fan Thermal switch Over current protection / Thermal protection Inverter Refrigerant High press. pipe piping diameter Low press. pipe ø15.88 Flare ø28.58 Brazed 50~130% of outdoor unit capacity Total capacity Indoor unit Model P20~P250 / 1~32 Model / Quantity Noise level Y-20˜26(R410A) Hermetic *2 62 / 62.5 dB Net weight 455 kg Cooling Operating temperature range Indoor : 15˚CWB ~ 24˚CWB Outdoor: -5˚CDB ~ 43˚CDB (0˚CDB ~ 43˚CDB, when the outdoor unit is at a lower position) Heating Indoor : 15˚CDB ~ 27˚CDB Outdoor: -20˚CWB ~ 15.5˚CWB Note: *1. Cooling/Heating capacity indicates the maximum value at operation under the following condition. Indoor : 27˚CDB / 19.5˚CWB Outdoor : 35˚CDB Indoor : 27˚CDB / 19˚CWB Outdoor : 35˚CDB Pipe length : 5m Height difference : 0m Indoor : 20˚CDB Outdoor : 7˚CDB / 6˚CWB Pipe length : 7.5m Height difference : 0m *2. It is measured in anechoic room. ** Installation/foundation work, electrical connection work, duct work, insulation work, power source switch, and other items shall be referred to the Installation Manual. Ref.: M-WYNCO-6936&6949 2- 41 2- 42 Y-20˜26(R410A) 2. Capacity Table 2-1. Correction by temperature Cooling • Standard Specifications PUHY-P500YGM PUHY-P650YGM Capacity kW 56.0 73.0 Input kW 15.59 19.65 Capacity at 100% indoor units running 1.4 1.3 Ratio 24˚CWB 1.1 22˚CWB 1.0 20˚CWB 18˚CWB 0.9 Indoor Temperature(˚CWB) 16˚CWB 0.8 15˚CWB 0.7 0.6 0.5 -5 0 5 10 15 20 25 30 35 40 45 Outdoor Temperature (˚CDB) Power Input at 100% indoor units running 1.4 1.3 24˚CWB 22˚CWB 20˚CWB 18˚CWB 16˚CWB 15˚CWB 1.2 Ratio 1.1 1.0 0.9 Indoor Temperature(˚CWB) 0.8 0.7 0.6 0.5 -5 0 5 10 15 20 25 30 35 40 45 Outdoor Temperature (˚CDB) Ref: cap&inpc-p450-650 2- 43 Y-20˜26(R410A) 1.2 Heating • Standard Specifications PUHY-P500YGM PUHY-P650YGM Capacity kW 63.0 81.5 Input kW 15.89 19.82 Capacity at 100% indoor units running 1.3 1.2 Ratio 1.0 20˚CDB 0.9 0.8 Indoor Temperature(˚CDB) 25˚CDB 27˚CDB 0.7 0.6 0.5 0.4 -20 -15 -10 -5 0 5 10 15 Outdoor Temperature (˚CWB) Power Input at 100% indoor units running 1.3 1.2 1.1 Indoor Temperature(˚CDB) 1.0 15˚CDB Ratio Y-20˜26(R410A) 15˚CDB 1.1 0.9 0.8 20˚CDB 0.7 25˚CDB 0.6 27˚CDB 0.5 0.4 -20 -15 -10 -5 0 5 10 15 Outdoor Temperature (˚CWB) Ref: cap&inph-p450-650 2- 44 2-2. Correction by total indoor PUHY-P500YGM Capacity(kW) 1) Capacity 70.0 65.0 60.0 55.0 50.0 45.0 40.0 35.0 30.0 25.0 20.0 Heating Cooling 200 250 300 350 400 450 500 550 600 Total capacity of indoor units 650 700 Y-20˜26(R410A) Capacity(kW) 800 Ref: pl-puhy500ygmc 2) Input 17.00 16.00 15.00 14.00 13.00 12.00 11.00 10.00 9.00 8.00 7.00 6.00 750 Heating Cooling 200 250 300 350 400 450 500 550 600 650 700 750 800 Ref: pl-puhy500ygmi Total capacity of indoor units PUHY-P650YGM Capacity(kW) 1) Capacity 90.0 85.0 80.0 75.0 70.0 65.0 60.0 55.0 50.0 45.0 40.0 35.0 30.0 Heating Cooling 300 350 400 450 500 550 600 650 700 750 Total capacity of indoor units 800 550 600 650 700 750 Total capacity of indoor units 800 850 900 Capacity(kW) 1000 Ref: pl-puhy650ygmc 2) Input 20.00 19.00 18.00 17.00 16.00 15.00 14.00 13.00 12.00 11.00 10.00 9.00 8.00 950 Heating Cooling 300 350 400 450 500 2- 45 850 900 950 1000 Ref: pl-puhy650ygmi 2-3. Correction by refrigerant piping length Y-20˜26(R410A) Due to the extension of refrigerant piping, a decrease of cooling/heating capacity happens. The actual capacity is considered by multiplying the correction factor according to the equivalent length of the refrigerant piping shown at the table below. 2- 46 2-4. Correction at frosting and defrosting Due to frosting at the outdoor heat exchanger and the automatical defrosting operation, the heating capacity of the outdoor unit should be considered by multiplying the correction factor which shown in the table below. Y-20˜26(R410A) 2-5. Operation limit • Cooling Indoor temperature (˚CWB) 30 25 20 15 10 5 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 Outdoor temperature (˚CDB) * The operation temperature of outdoor unit is limited into 0~43˚CDB when the outdoor unit is at a postion lower than the indoor units. • Heating Indoor temperature (˚CDB) 30 25 20 15 10 5 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 Outdoor temperature (˚CWB) Ref.: ol-ygmhp 2- 47 3. Sound Levels PUHY-P500YGM Measurement condition dB(A) 63Hz 125Hz 250Hz 50Hz 67 61.5 60.5 500Hz 1000Hz 2000Hz 4000Hz 8000Hz 58 53.5 50.5 48 43 60 60Hz 68 65 60.5 59 54 51.5 49 43.5 61 50Hz 60Hz Y-20˜26(R410A) Measurement location 1m 1m OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20µPa 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 Approximate minimum audible limit on continuous noise 63 125 250 NC-20 500 1000 2000 4000 8000 OCTAVE BAND CENTER FREQUENCIES (Hz) Ref.: h500ygm-WYNB0-3277 PUHY-P650YGM Measurement condition dB(A) 63Hz 125Hz 250Hz 50Hz 69.5 63 61.5 500Hz 1000Hz 2000Hz 4000Hz 8000Hz 59.5 54.5 52.5 54 47 62 60Hz 65 67 62 59.5 55 53 54.5 49 62.5 50Hz 60Hz Measurement location 1m 1m OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20µPa 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 Approximate minimum audible limit on continuous noise 63 125 250 NC-20 500 1000 2000 4000 8000 OCTAVE BAND CENTER FREQUENCIES (Hz) Ref.: h650ygm-WYNB0-3280 2- 48 4. External Dimensions Unit : mm Ref: ygm-W656820 1/2 Y-20˜26(R410A) 2- 49 2- 50 A 450 B B A A Ref: ygm-W656820 2/2 1000 Wall height 1000 Wall height M10 Anchor Bolt Corner Wall height A Wall height A B ❈ B ❈ 1000 450 ❈ A Wall height 450 A B B A 1000 Wall height 450 A B 450 A 1Space required for collective installation and continuous installation: When installing several units, provide the space between each block considering passage for air and people. 2Open in two directions. 3In case of wall height exceeds total height of unit,add dimension (h=wall height -total height of unit) to ❈ marked dimension. 4If there is a wall at both the front and the rear of the unit, install up to three units consecutively in the side direction and provide a space of 1000 mm or more as inlet space/passage space for each three units. ✻ In case of collective installation and continuous installation 1When building the foundation, give full attention to the floor strength, drain water disposal , piping and wiring routes. 2Be sure that the corners are firmly seated.If the corners are not firmly seated, the installation feet may be bent. 3When down piping and down wiring are performed, be sure that foundation and base work does not block the base through holes. 2.Foundation work No restrictions on wall height A 450 H H’ 1Wall heights of the front and the back sides shall be within total height of unit. 2When wall height exceeds total height of unit, add dimension to 450 of the following figure. h=wall height -total height of unit. [When inlet air enters from right and left sides of unit] Front 450 450 1Since the service from the back of unit is required, provide the back space 450 mm or above as the front. ✻ In case of single installation [Basic rules for spacing the unit] 1.Space required around unit 450 450 h H 450 450 450 900 450 A 450 A B (Unit : mm) B Must be open A Front 450 ❈ Wall height 450 900 Y-20˜26(R410A) Spacing of PUHY-P500,650YGM-A(-BS) 50/60Hz 380/400/415V Power source 3N~ SV 5b PE V U MC2 W 1 CN32 2 3 1 CN33 2 3 4 5 6 1 2 CN34 3 red 4 5 6 1 CN36 2 3 4 5 6 7 8 9 1 2 CN35 3 red 1 2 CN38 3 green CN21 1 2 3 blue 52C2 51C2 F11 AC660V 50A F detection circuit detection circuit F02 250VAC 6.3A T CN52C 1 yellow 2 X52 3 ACNF1 (Noise Filter) red L1 white L2 black L3 blue N E red Motor (Compressor) F12 AC660V 50A F blue 52 C1 white Ref: Y-p450~650ygm-W274629 PUHY-P550,P600,P650YGM-A 75A PUHY-P450,500YGM-A 60A N L3 black N L2 white L3 M1 M2 TB3 M1 S M2 TB7 L2 shield shield 21S 4b SV 5c SV1 3 2 1 3 2 L1 CH11 21S 4a SV3 21S 4c 63H2 63H1 black 123 45 X01 X02 X03 X05 X06 X07 X08 X09 CN20 F01 250VAC 6.3A T 2 1 CN01 63HS CNL black 3 2 1 LD1 1 1 1 1 Unit address setting SWU2 SWU1 ✻1 ~ ~ - ~ + black red DS1 (Diode stack) 1 2 3 CNS2 blue ZNR14 1 2 CNS1 blue C15 R23 3 2 1 52C1 R11 R12 Refer to the service handbook about the switch operations. 2 1 0 SWU3 10 10 10 10 10 SW5 SW4 SW3 SW2 SW1 1 2 1 R22 CNH CNTYP4 CNTYP5 3 2 1 1 2 3 63LS 1 2 3 red white black Control circuit board (MAIN BOARD) CN13 4 3 2 1 TH12 TH11 red white black OFF ON OFF ON OFF ON OFF ON OFF ON CN02 detection circuit 8 7 6 5 4 3 2 1 2 1 TH8 TH7 TH6 TH5 CNTYP1 red Z20 DCL1 CNLVB red 123456 LEV1 C12 C11 + + R14 R13 1 2 3 CNVCC1 4 5 6 7 8 1 2 3 CNRS3B 4 5 6 7 CNAC3 2 black 3 1 1 2 3 CNRS3A 4 5 6 7 2 1 CNRT1 4 3 red 5 1 2 CNOUT1 3 yellow 4 5 6 12V CN51 CN3N 3 blue 21 CN3S 3 2 red 1 1 3 CN3D 2 5 4 3 2 1 ) DCCT1 1234 black red C14 T01 (Transfomer) Trouble Compressor ON/OFF N P ✻1 4 3 2 1 ACCT-U IPM1 ON OFF U red CNVDC ACCT1 123 V 1 2 14 1 14 9 9 1 1 1 2 3 4 1 2 3 4 1 CNDC1 black CNDR1 W CN15V2 CNDR2 CNDC2 black CNVCC1 12345678 CNOUT2 1 2 3 4 543 2 1 X2 SW1 F01 250VAC 2A T 1 12 345 ON OFF ON OFF 1 2 3 4 CNCT 6 1 2 CNTH green CNCH 2 3 blue 1 1 CN52F 2 yellow 3 2 1 CNFAN X01 red 3 CNFG 1 blue 2 CNRS1 1234567 52F 52 C2 W 3 3 CN04 V U W U V 1 2 3 1 2 CH12 1 2 4 2 3 CN05 1 A1 A1 MF3 52F A2 13 14 4 5 A2 52C2 1 95 96 51C2 CN52C2 2 blue 3 THHS1 SW2 1 LED1 operation LED2 error 4 CNRT2 X3 X1 1 CN51C2 2 3 RELAY-BOARD1 Power circuit board 1 (INV BOARD) CNAC2 F02 700VDC 2A T 4 3 CNCT2 2 blue 1 L1 1 2 L2 CNL1 1 2 1 2 3 4 5 6 7 8 CNL2 1 FILTER 2 3 BOARD 4 5 6 CNIN 7 CNOUT blue 8 green CNFG blue ACCT-W white black SW2 4 6 5 4 3 2 1 Gate amp board 1 (G/A BOARD) CN15V1 CNDC2 1 2 CNTR 3 1 LED1 operation LED2 error FAN control board (FAN BOARD) CNINV ✻2 or STEP DEMAND 1 2 3 4 5 CNRS2 6 7 AUTO CHANGEOVER HEAT/COOL SNOW Compressor ON/OFF NIGHT MODE Fan motor (Heat exchanger) U VMC1 W Motor (Compressor) Fan motor MF1 (Heat exchanger) MF2 Name Low pressure sensor Choke coil (Transmission) Function device L1,L2 Z20 OFF SHORT 75% 50% 0% SHORT 100% OPEN OFF NOTE:The broken lines indicate field wiring. HEAT COOL CN3N 1-2P OPEN SHORT Auto changeover:OFF SHORT Auto changeover:ON OPEN CN3N 1-3P ✻2:Auto changeover (CN3N 1-2P,1-3P) OPEN SHORT CN3D 1-2P CN3D 1-3P SW4-7:ON (STEP DEMAND) SHORT ON ON OPEN MODE OPEN ON/OFF 1-3P NIGHT 1-2P Compressor CN3D CN3D ✻1: Function according to switch operation. (SW4-7,CN3D 1-2P,and CN3D 1-3P) SW4-7:OFF (Compressor ON/OFF and NIGHT MODE) Earth terminal High pressure sensor 63LS High pressure switch bypass outlet temp.detect at Sub-cool coil Radiator panel temp. detect liquid outlet temp.detect at Sub-cool coil OA temp.detect Pipe temp.detect (Hex outlet) Discharge pipe temp. detect Electronic expansion valve (SC coil) Solenoid valve (Heat exchanger capacity control) Solenoid valve (Discharge-suction bypass) 4-way valve Crank case heater (Compressor) Fan motor (Radiator panel) Magnetic contactor (Fan motor) Overload relay (No.2 Compressor) Magnetic contactor (No.2 Compressor) Magnetic contactor (Inverter main circuit) DC reactor (Power factor improvement) DC Current Sensor AC Current Sensor 63HS 63H1,2 THHS1 TH8 TH7 TH6 TH5 TH11,12 LEV1 SV5b,c SV1,3 21S4a,b,c CH11,12 MF3 52F 51C2 52C2 52C1 DCL1 DCCT1 ACCT1 Symbol < Symbol explanation > Thermistor 1 TB1 (Terminal Block) L1 red INDOOR/ OUTDOOR TRANSMISSION LINE CENTRAL CONTROL TRANSMISSION LINE Breakers for wiring Breakers for current leakage 2- 51 Y-20˜26(R410A) Inverter controller box 5. Electrical Wiring Diagram PUHY-P500, 650YGM-A(-BS) 2- 52 SV5b Ref: rcd-450~650ygmhp TH6 HEX1b (F) HEX1a (F) HEX2b (B) 21S4b SV5c 21S4c TH5 HEX2a (B) 21S4a TH8 63H1 O/S SCC COMP 1 TH11 CV1 CP1 CP3 ST9 LEV1 ST8 Oil Tank CP2 ST6 SV1 ST5 63HS CJ1 CJ3 TH7 63H2 O/S Drier ST7 CV2 SV3 COMP 2 TH12 ACC ST13 ST12 ST11 ST10 Y-20˜26(R410A) 63LS CJ2 ST2 ST1 BV2 BV1 6. Refrigerant Circuit Diagram And Thermal Sensor PUHY-P500, 650YGM-A(-BS)