Preview only show first 10 pages with watermark. For full document please download

Pumy-p-vhmb Databook

   EMBED


Share

Transcript

Artwork (2-1 to 2-100):Artwork 24/08/2009 14:51 Page 7 S SERIES DATA G6 OUTDOOR UNITS I.S SERIES 1. SPECIFICATIONS........................................................................................................................................... 2 - 8 2. EXTERNAL DIMENSIONS .............................................................................................................................. 2 - 12 3. CENTER OF GRAVITY ................................................................................................................................... 2 - 13 4. ELECTRICAL WIRING DIAGRAMS ................................................................................................................ 2 - 14 5. REFRIGERANT CIRCUIT DIAGRAMS ........................................................................................................... 2 - 16 6. SOUND LEVELS ............................................................................................................................................. 2 - 17 7. CAPACITY TABLES ........................................................................................................................................ 2 - 18 7-1. Correction by temperature ....................................................................................................................... 2 - 18 7-2. Correction by total indoor......................................................................................................................... 2 - 20 7-3. Correction by refrigerant piping length..................................................................................................... 2 - 22 7-4. Correction at frost and defrost ................................................................................................................. 2 - 23 7-5. Operation temperature range .................................................................................................................. 2 - 23 8. OPTIONAL PARTS.......................................................................................................................................... 2 - 24 8-1. JOINT ...................................................................................................................................................... 2 - 24 8-2. HEADER .................................................................................................................................................. 2 - 25 OUTDOOR UNITS 2-7 Artwork (2-1 to 2-100):Artwork 24/08/2009 14:51 Page 8 1. SPECIFICATIONS DATA G6 I.SSPECIFICATIONS 1. SERIES S Model Power source PUMY-P100YHMB PUMY-P125YHMB 3-phase 4-wire 380-400-415V 50Hz 3-phase 4-wire 380-400-415V 50Hz Cooling capacity *1 kW 11.2 14.0 (Nominal) *1 kcal / h 9,600 12,000 47,800 *1 BTU / h 38,200 Power input kW 3.30 4.27 Current input A 5.28-5.02-4.84 6.83-6.49-6.26 COP kW / kW Temp. range of Indoor W.B. cooling Outdoor D.B. 3.39 3.28 15 to 24degC(59 to 75degF) 15 to 24degC(59 to 75degF) -5 to 46degC(23 to 115degF) -5 to 46degC(23 to 115degF) 10 to 46degC(50 to 115degF) : in case of connecting PKFY-P15/P20/P25 type indoor unit. 10 to 46degC(50 to 115degF) : in case of connecting PKFY-P15/P20/P25 type indoor unit. Heating capacity *2 kW 12.5 16.0 (Nominal) *2 kcal / h 10,800 13,800 54,600 Temp. range of *2 BTU / h 42,700 Power input kW 3.63 4.29 Current input A 5.81-5.52-5.32 6.87-6.52-6.29 COP kW / kW Indoor D.B. W.B. heating Outdoor Indoor unit Total capacity connectable Model / Quantity 3.44 3.73 15 to 27degC(59 to 81degF) 15 to 27degC(59 to 81degF) -15 to 15degC(5 to 59degF) -15 to 15degC(5 to 59degF) 50 to 130 % of outdoor unit capacity 50 to 130 % of outdoor unit capacity P15 to P125 / 1 to 8 P15 to P140 / 1 to 10 Sound pressure level (measured in anechoic room) dB Refrigerant Liquid pipe mm(in.) piping diameter Gas pipe mm(in.) FAN Type x Quantity Air flow rate 49 / 51 50 / 52 9.52(3/8) Flare 9.52(3/8) Flare 15.88(5/8) Flare 15.88(5/8) Flare Propeller fan x 2 Propeller fan x 2 m3 / min L/s cfm Control, Driving mechanism Motor output Compressor Type x Quantity Manufacture 3,532 3,532 DC-control, Direct-driven by motor 0.06 x 2 0.06 x 2 0 Pa (0 mmH2O) 0 Pa (0 mmH2O) Inverter scroll hermetic compressor Inverter scroll hermetic compressor MITSUBISHI ELECTRIC CORPORATION MITSUBISHI ELECTRIC CORPORATION Starting method Inverter Inverter Motor output kW 1.9 2.4 Case heater kW - - FV50S FV50S Lubricant External finish External dimension HxWxD Protection devices Galvanized steel sheets Galvanized steel sheets mm 1,350 x 950 x 330 1,350 x 950 x 330 in. 53-3/16 x 37-7/16 x 13 53-3/16 x 37-7/16 x 13 High pressure sensor, High pressure switch at 4.15MPa (601 psi) High pressure sensor, High pressure switch at 4.15MPa (601 psi) High pressure protection Inverter circuit (COMP. / FAN) Compressor Fan motor Refrigerant Type x original charge Over-heat protection,Over-current protection Over-heat protection,Over-current protection Discharge thermo protection,Over-current protection Discharge thermo protection,Over-current protection Over-heat protection,Voltage protection Over-heat protection,Voltage protection R410A x 8.5kg (19lbs) R410A x 8.5kg (19lbs) LEV circuit LEV circuit Control Net weight kg(lbs) Heat exchanger 142(312) 142(312) Salt-resistant cross fin & copper tube Salt-resistant cross fin & copper tube HIC circuit (HIC: Heat Inter-Changer) Defrosting method Drawing Standard attachment 100 1,667 DC-control, Direct-driven by motor kW External static press. 100 1,667 - - Auto-defrost mode (Reversed refrigerant cycle) Auto-defrost mode (Reversed refrigerant cycle) External YHM-BK01-B328 YHM-BK01-B328 Wiring YHM-RG79-V705 YHM-RG79-V705 Document Installation Manual Installation Manual Accessory Grounded lead wire x 2 Grounded lead wire x 2 Optional parts Remarks Joint: CMY-Y62-G-E Joint: CMY-Y62-G-E Header: CMY-Y64/68-G-E Header: CMY-Y64/68-G-E * Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual. * Due to continuing improvement, above specifications may be subject to change without notice. Notes : Unit converter *1.Nominal cooling conditions(subject to JIS B8615-1) kcal =kW x 860 Indoor : 27degCDB/19degCWB(81degFDB/66degFWB), Outdoor : 35degCDB(95degFDB) BTU/h =kW x 3,412 Pipe length : 7.5m(24-9/16ft.), Level difference : 0m(0ft.) cfm =m3/min x 35.31 lb =kg / 0.4536 *2.Nominal heating conditions(subject to JIS B8615-1) Indoor : 20degCDB(68degFDB), Outdoor : 7degCDB/6degCWB(45degFDB/43degFWB) Pipe length : 7.5m(24-9/16ft.), Level difference : 0m(0ft.) *Above specification data is subject to rounding variation. OUTDOOR UNITS 2-8 Artwork (2-1 to 2-100):Artwork 24/08/2009 14:51 Page 9 1. SPECIFICATIONS DATA G6 Model PUMY-P140YHMB 3-phase 4-wire 380-400-415V 50Hz Cooling capacity *1 kW (Nominal) *1 kcal / h 13,300 *1 BTU / h 52,900 Power input kW Current input A COP kW / kW Temp. range of Indoor W.B. cooling Outdoor D.B. S Power source 15.5 5.32 8.51-8.09-7.80 2.91 15 to 24degC(59 to 75degF) -5 to 46degC(23 to 115degF) 10 to 46degC(50 to 115degF) : in case of connecting PKFY-P15/P20/P25 type indoor unit. Heating capacity *2 kW (Nominal) *2 kcal / h 15,500 *2 BTU / h 61,400 Power input kW Current input A COP kW / kW Temp. range of Indoor D.B. heating Outdoor W.B. Indoor unit Total capacity connectable Model / Quantity 18.0 5.32 8.51-8.09-7.80 3.38 15 to 27degC(59 to 81degF) -15 to 15degC(5 to 59degF) 50 to 130 % of outdoor unit capacity P15 to P140 / 1 to 12 Sound pressure level (measured in anechoic room) dB Refrigerant Liquid pipe mm(in.) piping diameter Gas pipe mm(in.) FAN Type x Quantity Air flow rate 51 / 53 9.52(3/8) Flare 15.88(5/8) Flare Propeller fan x 2 m3 / min 100 L/s 1,667 cfm Control, Driving mechanism Motor output kW External static press. Compressor 3,532 DC-control, Direct-driven by motor 0.06 x 2 0 Pa (0 mmH2O) Type x Quantity Inverter scroll hermetic compressor Manufacture MITSUBISHI ELECTRIC CORPORATION Starting method Inverter Motor output kW Case heater kW 2.9 - Lubricant FV50S External finish Galvanized steel sheets External dimension HxWxD Protection devices mm 1,350 x 950 x 330 in. 53-3/16 x 37-7/16 x 13 High pressure sensor, High pressure switch at 4.15MPa (601 psi) High pressure protection Inverter circuit (COMP. / FAN) Compressor Fan motor Refrigerant Over-heat protection,Over-current protection Discharge thermo protection,Over-current protection Over-heat protection,Voltage protection Type x original charge R410A x 8.5kg (19lbs) Control Net weight LEV circuit kg(lbs) Heat exchanger 142(312) Salt-resistant cross fin & copper tube HIC circuit (HIC: Heat Inter-Changer) Defrosting method Drawing Standard attachment Auto-defrost mode (Reversed refrigerant cycle) External YHM-BK01-B328 Wiring YHM-RG79-V705 Document Installation Manual Accessory Grounded lead wire x 2 Optional parts Joint: CMY-Y62-G-E Header: CMY-Y64/68-G-E Remarks * Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual. * Due to continuing improvement, above specifications may be subject to change without notice. Notes : Unit converter *1.Nominal cooling conditions(subject to JIS B8615-1) kcal =kW x 860 Indoor : 27degCDB/19degCWB(81degFDB/66degFWB), Outdoor : 35degCDB(95degFDB) BTU/h =kW x 3,412 Pipe length : 7.5m(24-9/16ft.), Level difference : 0m(0ft.) cfm =m3/min x 35.31 lb =kg / 0.4536 *2.Nominal heating conditions(subject to JIS B8615-1) Indoor : 20degCDB(68degFDB), Outdoor : 7degCDB/6degCWB(45degFDB/43degFWB) Pipe length : 7.5m(24-9/16ft.), Level difference : 0m(0ft.) *Above specification data is subject to rounding variation. OUTDOOR UNITS 2-9 Artwork (2-1 to 2-100):Artwork 24/08/2009 14:51 Page 10 1. SPECIFICATIONS DATA G6 S Model Power source PUMY-P100VHMB PUMY-P125VHMB 1-phase 220-230-240V 50Hz / 1-phase 220V 60Hz 1-phase 220-230-240V 50Hz / 1-phase 220V 60Hz Cooling capacity *1 kW 11.2 14.0 (Nominal) *1 kcal / h 9,600 12,000 47,800 *1 BTU / h 38,200 Power input kW 3.34 4.32 Current input A 15.4-14.8-14.1 / 15.4 20.0-19.1-18.3 / 20.0 COP kW / kW Temp. range of Indoor W.B. cooling Outdoor D.B. 3.35 3.24 15 to 24degC(59 to 75degF) 15 to 24degC(59 to 75degF) -5 to 46degC(23 to 115degF) -5 to 46degC(23 to 115degF) 10 to 46degC(50 to 115degF) : in case of connecting PKFY-P15/P20/P25 type indoor unit. 10 to 46degC(50 to 115degF) : in case of connecting PKFY-P15/P20/P25 type indoor unit. Heating capacity *2 kW 12.5 16.0 (Nominal) *2 kcal / h 10,800 13,800 54,600 Temp. range of *2 BTU / h 42,700 Power input kW 3.66 4.33 Current input A 16.9-16.2-15.5 / 16.9 20.0-19.1-18.3 / 20.0 COP kW / kW Indoor D.B. W.B. heating Outdoor Indoor unit Total capacity connectable Model / Quantity 3.42 3.69 15 to 27degC(59 to 81degF) 15 to 27degC(59 to 81degF) -15 to 15degC(5 to 59degF) -15 to 15degC(5 to 59degF) 50 to 130 % of outdoor unit capacity 50 to 130 % of outdoor unit capacity P15 to P125 / 1 to 8 P15 to P140 / 1 to 10 Sound pressure level (measured in anechoic room) dB Refrigerant Liquid pipe mm(in.) piping diameter Gas pipe mm(in.) FAN Type x Quantity Air flow rate 49 / 51 50 / 52 9.52(3/8) 9.52(3/8) 15.88(5/8) 15.88(5/8) Propeller fan x 2 Propeller fan x 2 m3 / min L/s cfm Control, Driving mechanism Motor output Compressor Type x Quantity Manufacture 3,532 3,532 DC-control, Direct-driven by motor 0.06 x 2 0.06 x 2 0 Pa (0 mmH2O) 0 Pa (0 mmH2O) Inverter scroll hermetic compressor Inverter scroll hermetic compressor MITSUBISHI ELECTRIC CORPORATION MITSUBISHI ELECTRIC CORPORATION Starting method Inverter Inverter Motor output kW 2.2 2.9 Case heater kW - - FV50S x 2.3L FV50S x 2.3L Lubricant External finish External dimension HxWxD Protection devices Galvanized steel sheets Galvanized steel sheets mm 1,350 x 950 x 330 1,350 x 950 x 330 in. 53-3/16 x 37-7/16 x 13 53-3/16 x 37-7/16 x 13 High pressure sensor, High pressure switch at 4.15MPa (601 psi) High pressure sensor, High pressure switch at 4.15MPa (601 psi) High pressure protection Inverter circuit (COMP. / FAN) Compressor Fan motor Refrigerant Type x original charge Over-heat protection,Over-current protection Over-heat protection,Over-current protection Discharge thermo protection,Over-current protection Discharge thermo protection,Over-current protection Over-heat protection,Voltage protection Over-heat protection,Voltage protection R410A x 8.5kg (19lbs) R410A x 8.5kg (19lbs) LEV circuit LEV circuit Control Net weight kg(lbs) Heat exchanger 129(284) 129(284) Salt-resistant cross fin & copper tube Salt-resistant cross fin & copper tube HIC circuit (HIC: Heat Inter-Changer) Defrosting method Drawing Standard attachment 100 1,667 DC-control, Direct-driven by motor kW External static press. 100 1,667 - - Auto-defrost mode (Reversed refrigerant cycle) Auto-defrost mode (Reversed refrigerant cycle) External VHM-BK01-B434 VHM-BK01-B434 Wiring VHM-RG79-V708 VHM-RG79-V708 Document Installation Manual Installation Manual Accessory Grounded lead wire x 2 Grounded lead wire x 2 Optional parts Remarks Joint: CMY-Y62-G-E Joint: CMY-Y62-G-E Header: CMY-Y64/68-G-E Header: CMY-Y64/68-G-E * In case of connecting Fresh air intake type indoor unit PEFY-P-VHM-E-F, only one indoor unit can be connected with one PUMY. * Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual. * Due to continuing improvement, above specifications may be subject to change without notice. Notes : Unit converter *1.Nominal cooling conditions(subject to JIS B8615-1) kcal =kW x 860 Indoor : 27degCDB/19degCWB(81degFDB/66degFWB), Outdoor : 35degCDB(95degFDB) BTU/h =kW x 3,412 Pipe length : 7.5m(24-9/16ft.), Level difference : 0m(0ft.) cfm =m3/min x 35.31 lb =kg / 0.4536 *2.Nominal heating conditions(subject to JIS B8615-1) Indoor : 20degCDB(68degFDB), Outdoor : 7degCDB/6degCWB(45degFDB/43degFWB) Pipe length : 7.5m(24-9/16ft.), Level difference : 0m(0ft.) *Above specification data is subject to rounding variation. OUTDOOR UNITS 2 - 10 Artwork (2-1 to 2-100):Artwork 24/08/2009 14:51 Page 11 1. SPECIFICATIONS DATA G6 Model PUMY-P140VHMB 1-phase 220-230-240V 50Hz / 1-phase 220V 60Hz Cooling capacity *1 kW (Nominal) *1 kcal / h 13,300 *1 BTU / h 52,900 Power input kW Current input A COP kW / kW Temp. range of Indoor W.B. cooling Outdoor D.B. S Power source 15.5 5.35 24.7-23.6-22.7 / 24.7 2.9 15 to 24degC(59 to 75degF) -5 to 46degC(23 to 115degF) 10 to 46degC(50 to 115degF) : in case of connecting PKFY-P15/P20/P25 type indoor unit. Heating capacity *2 kW (Nominal) *2 kcal / h 15,500 *2 BTU / h 61,400 Power input kW Current input A COP kW / kW Temp. range of Indoor D.B. heating Outdoor W.B. Indoor unit Total capacity connectable Model / Quantity 18.0 5.58 25.8-24.7-23.6 / 25.8 3.23 15 to 27degC(59 to 81degF) -15 to 15degC(5 to 59degF) 50 to 130 % of outdoor unit capacity P15 to P140 / 1 to 12 Sound pressure level (measured in anechoic room) dB Refrigerant Liquid pipe mm(in.) piping diameter Gas pipe mm(in.) FAN Type x Quantity Air flow rate 51 / 53 9.52(3/8) 15.88(5/8) Propeller fan x 2 m3 / min 100 L/s 1,667 cfm Control, Driving mechanism Motor output kW External static press. Compressor 3,532 DC-control, Direct-driven by motor 0.06 x 2 0 Pa (0 mmH2O) Type x Quantity Inverter scroll hermetic compressor Manufacture MITSUBISHI ELECTRIC CORPORATION Starting method Inverter Motor output kW Case heater kW Lubricant 3.3 FV50S x 2.3L External finish Galvanized steel sheets External dimension HxWxD Protection devices mm 1,350 x 950 x 330 in. 53-3/16 x 37-7/16 x 13 High pressure sensor, High pressure switch at 4.15MPa (601 psi) High pressure protection Inverter circuit (COMP. / FAN) Compressor Fan motor Refrigerant Over-heat protection,Over-current protection Discharge thermo protection,Over-current protection Over-heat protection,Voltage protection Type x original charge R410A x 8.5kg (19lbs) Control Net weight LEV circuit kg(lbs) Heat exchanger 129(284) Salt-resistant cross fin & copper tube HIC circuit (HIC: Heat Inter-Changer) Defrosting method Drawing Standard attachment Auto-defrost mode (Reversed refrigerant cycle) External VHM-BK01-B434 Wiring VHM-RG79-V708 Document Installation Manual Accessory Grounded lead wire x 2 Optional parts Joint: CMY-Y62-G-E Header: CMY-Y64/68-G-E Remarks * In case of connecting Fresh air intake type indoor unit PEFY-P-VHM-E-F, only one indoor unit can be connected with one PUMY. * Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual. * Due to continuing improvement, above specifications may be subject to change without notice. Notes : Unit converter *1.Nominal cooling conditions(subject to JIS B8615-1) kcal =kW x 860 Indoor : 27degCDB/19degCWB(81degFDB/66degFWB), Outdoor : 35degCDB(95degFDB) BTU/h =kW x 3,412 Pipe length : 7.5m(24-9/16ft.), Level difference : 0m(0ft.) cfm =m3/min x 35.31 lb =kg / 0.4536 *2.Nominal heating conditions(subject to JIS B8615-1) Indoor : 20degCDB(68degFDB), Outdoor : 7degCDB/6degCWB(45degFDB/43degFWB) Pipe length : 7.5m(24-9/16ft.), Level difference : 0m(0ft.) *Above specification data is subject to rounding variation. OUTDOOR UNITS 2 - 11 150 FREE Over 150 10 Over Service space 500 Over Front piping hole (Knockout) Front trunking hole (Knockout) 92 n92 40 65 45 Power supply wiring hole (2- 27Knockout) Piping Knockout Hole Details Air intake Handle for moving Refrigerant GAS pipe connection(FLARE) 15.88(5/8 inch) Refrigerant LIQUID pipe connection(FLARE) 9.52(3/8 inch) 1·····Indication of STOP VALVE connection location. Example of Notes Over 1000 Over 10 3 FOUNDATION BOLTS 4 PIPING-WIRING DIRECTIONS 19 92 75 55 n92 40 65 45 Right trunking hole (Knockout) Power supply wiring hole (2- 27Knockout) FOUNDATION 30 Over Over 500 Right piping hole (Knockout) 63 23 27 92 73 Over 10 55 27 Less than 92 92 40 Rear piping hole (Knockout) Rear trunking hole (Knockout) 330 Handle for moving Side Air Intake Power supply wiring hole (2- 27Knockout) Handle for moving Handle for moving Side Air Intake Rear Air Intake Dimensions of space needed Please secure the unit The diagram below shows a Piping and wiring connections for service access are firmly with 4 foundation (M10) can be made from 4 directions: basic example. shown in the below diagram. bolts.(Bolts and washers must front, right, rear and below. Explantion of particular details is be purchased locally.) given in the installation manuals etc. 2 SERVICE SPACE 1350 0 3 7 322 220 5 600 Installation Feet 145 56 70 145 5 4 Drain hole 1 (5- 33) 71 5 7 1 2-U Shaped notched holes (Foundation Bolt M10) Ground for the power supply ("GR"marking position) 950 Air Discharge 2-12 36 Oval holes (Foundation Bolt M10) 1 Rear Air Intake Terminal block Left·········For the power supply Center····For the transmission line Right·······For concentration control 2 1 Handle for moving Service panel Ground for the transmission line Ground for concentration control ( 42 37 71 635 371 417 1 FREE SPACE (Around the unit) 73 63 23 73 63 23 55 27 Bottom piping hole (Knockout) Rear piping cover Front piping cover 1088 30 23 219 81 56 53 19 370 28 1 423 OUTDOOR UNITS 1 507 ) S Artwork (2-1 to 2-100):Artwork 24/08/2009 14:51 Page 12 2. EXTERNAL DIMENSIONS DATA G6 2. EXTERNAL DIMENSIONS PUMY-P100,125,140YHMB PUMY-P100,125,140VHMB Unit : mm 2 - 12 Artwork (2-1 to 2-100):Artwork 24/08/2009 14:51 Page 13 3. CENTER OF GRAVITY DATA G6 3. CENTER OF GRAVITY S PUMY-P100,125,140YHMB PUMY-P100,125,140VHMB X G G Z Model W D H X Y Z PUMY-P100VHMB-E PUMY-P125VHMB-E PUMY-P140VHMB-E PUMY-P100YHMB-E PUMY-P125YHMB-E PUMY-P140YHMB-E 950 330 1350 620 185 500 Y OUTDOOR UNITS 2 - 13 Artwork (2-1 to 2-100):Artwork 24/08/2009 14:51 Page 14 4. ELECTRICAL WIRING DIAGRAMS DATA G6 4. ELECTRICAL WIRING DIAGRAMS S PUMY-P100,125,140YHMB 1 CNF2 7 (WHT) CN3D CN3S CN3N (WHT) (RED) (BLU) 1 3 1 3 1 LED3 X502 X503 X504 21S4 SW1 SW8 SW2 CN4 CN2 (WHT) 1 (WHT) 7 1 2 2 LED2 LED1 CN102 (WHT) 1 CN41 CN40 4 (WHT) (WHT) 1 4 1 4 4 F2 SV1 1 2 7 CNS1 CNS2 (RED) (YLW) 1 SS 2 1 CNAC 1 2 1 2 (RED) (WHT) 1 SV2 2 1 SV1 3 (BLU) (WHT) SW6 SW4 SW3 SW7 1 CN51 5 (WHT) F1 1 21S4 3 (GRN) SWU2 SWU1 SW5 3 1 3 63L (RED) 3 63H (YLW) TRANS 1 CNDC (PNK) 1 52C 3 (BLK) t 1 3 2 t 2 2 M-NET P.B. TB-U TB-L3 TB-L2 TB-L1 + FOR CENTRALIZED CONTROL DC 30V(Non-polar) CB1 TB-N1 + 3 CK CB2 2 2 N. F. CNAC1 (WHT) 1 TB1 L1 L2 L3 N CNCT (RED) 1 2 1 3 CNAC2 3 (RED) LI1 LO1 RED LI2 U U LO2 WHT BLK LI3 U LO3 BLK BLU NI U NO BLU U GD3 2 CNDC 1 (PNK) 2 3 3 ACL3 WHT - 1 CNL (BLU) WHT WHT 1 BLK BLK 1 MODEL SELECT 1:ON 0:OFF SW4 MODELS 1 2 3 4 5 6 PUMY-P100YHMB 1 1 0 0 1 0 PUMY-P125YHMB 1 1 0 0 0 1 PUMY-P140YHMB 1 1 0 0 1 1 CNAC1 3 (WHT) ACL2 + + GD1 RED ACL1 RED U L2-A2 Conv.B. WHT GRN/YLW POWER SUPPLY 3N~ 400V 50Hz WHT 3 1 N-IN S L2-OU + TB-C1 TB-P2 L1-IN + RED YLW BLK WHT RED BLU - 2 BLK + X52A BLK W MC WHT V MS 3~ RED U L3-A2 M1 M2 RED YLW 2 - RS TB7 2 TB-W TB-V + RED TO INDOOR UNIT CONNECTING WIRES DC 30V(Non-polar) 2 CN4 1 (WHT) 2 CN5 1 (RED) BLK 2 L3-OU S CN7 (WHT) 7 1 3 1 CN2 CN7 (WHT) (WHT) RED L1-A1 M1 M2 1 CN2 4 (WHT) TP1 BLK CN1 (WHT) 1 5 7 3 P. B. RED 2 RED TB3 4 RED MF2 MS 3~ t 1 3 1 4 1 2 2 1 63HS TH7/6 TH3 TH4 (WHT) (RED) (WHT) (WHT) X501 CNF1 7 (WHT) L1-A2 t 1 L1-OU C. B. MF1 MS 3~ 63H 63L 63HS TH7 TH6 TH3 TH4 BLK CK-OU NAME Terminal Block Terminal Block Terminal Block Motor For Compressor Fan Motor Solenoid Valve High Pressure Switch Low Pressure Switch High Pressure Sensor Solenoid Valve Thermistor Thermistor Thermistor Thermistor Rush Current Protect Resistor Reactor Main Smoothing Capacitor Capacitor Power Circuit Board Connection Terminal Connection Terminal Connection Terminal Connection Terminal Connection Terminal Relay Noise Filter Circuit Board Connection Terminal Connection Terminal Connection Terminal Converter Circuit Board Connection Terminal Connection Terminal Connection Terminal Connection Terminal Connection Terminal Connection Terminal Controller Circuit Board Switch Switch Switch Switch Switch Switch Switch Switch Switch Switch Connector Connector Connector Connector Connector LED LED Fuse Relay M-NET Power Circuit Board Connection Terminal X505 SYMBOL TB1 TB3 TB7 MC MF1,MF2 21S4 63H 63L 63HS SV1 TH3 TH4 TH6 TH7 RS ACL1~ACL4 CB1,CB2 CK P.B. TB-U/V/W TB-L1/L2/L3 TB-P2 TB-C1 TB-N1 X52A N.F. LO1/LO2/LO3/NO LI1/LI2/LI3/NI GD1,GD3 CONV.B. L1-A1/IN L1-A2/OU L2-A2/OU L3-A2/OU N-IN CK-OU C.B. SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 SWU1 SWU2 SS CN3D CN3S CN3N CN51 LED1,LED2 LED3 F1,F2 X501~X505 M-NET P.B. TP1 ACL4 Cautions when Servicing • ! WARNING: When the main supply is turned off, the voltage [570 V] in the main capacitor will drop to 20 V in approx. 5 minutes (input voltage: 400 V). When servicing, make sure that LED1 and LED2 on the outdoor circuit board goes out, and then wait for at least 5 minute. • Components other than the outdoor board may be faulty: Check and take corrective action, referring to the service manual. Do not replace the outdoor board without checking. NOTES: 1.Refer to the wiring diagrams of the indoor units for details on wiring of each indoor unit. Self-diagnosis function The indoor and outdoor units can be diagnosed automatically using the self-diagnosis switch (SW1), LED1 and LED2 (LED indication) found on the multi-controller of the outdoor unit. LED indication : Set all contacts of SW1 to OFF. • During normal operation The LED indicates the drive state of the controller in the outdoor unit. Bit Indication 1 Compressor operated 2 3 4 5 6 7 8 52C 21S4 SV1 (SV2) — — Always lit [Example] When the compressor and SV1 are turned on during cooling operation. 1 23 45 67 8 • When fault requiring inspection has occurred, the LED alternately indicates the inspection code and the location of the unit in which the fault has occurred. OUTDOOR UNITS 2 - 14 Artwork (2-1 to 2-100):Artwork 24/08/2009 14:51 Page 15 4. ELECTRICAL WIRING DIAGRAMS DATA G6 PUMY-P100,125,140VHMB S MULTI. B. MF1 MS 3~ t CNF1 7 (WHT) 1 MF2 MS 3~ t t t 3 1 TRANS 7 X501 X502 X503 X504 F2 2 2 SV1 SW4 SW3 SW7 4 1 M-NET P.B. LED1 LED2 1 CN2 4 (WHT) TP1 BLK CN1 5 (WHT)1 CN102 (WHT) 1 4 CN40 CN41 (WHT) (WHT) 1 1 4 4 2 4 2 P. B. TH8 2 YLW 2 + U YLW V S MS 3~ BLU WHT TABP1 RED U N. F. NO - + 2 1 2 2 3 1 W MC BLK E2 1 P N1 N2 BLK POWER SUPPLY ~/N 230V 50Hz TB1 RED L 1 Io 6 RED WHT ACTM BLK U BLU N I L2 2 2 CNAC1 (WHT) L1 RED + 3 CN5 (RED) 2 4 DCL 1 LI FOR CENTRALIZED CONTROL DC 30V(Non-polar) RED M2 2 WHT CE + RED TB7 M1 t TABS WHT CN52C (BLK) TO INDOOR UNIT CONNECTING WIRES DC 30V(Non-polar) 7 1 CN3 2 (WHT) 1 CN5 2 (RED) 1 CN4 2 (WHT) TABN TABP DS2 + LO S 3 52C RED IPM TABT BLU CNAC2 (RED) CN2 (WHT) DS3 + WHT TABN2 6 1 7 CNDC (PIN) 2 1 TABP2 M2 CNAF (WHT) RED TABU WHT TABV BLK TABW 2 M1 RED TABN1 BLK 1 TB3 RED 4 N U EI BLU 1 MODEL SELECT 1:ON 0:OFF SW4 MODELS 1 2 3 4 5 6 PUMY-P100VHMB 0 1 0 0 1 0 PUMY-P125VHMB 0 1 0 0 0 1 PUMY-P140VHMB 0 1 0 0 1 1 GRN/YLW Cautions when Servicing ! 2 2 CNS1 CNS2 (RED) (YLW) 1 SS 2 1 CNAC 1 2 1 2 (RED) (WHT) 1 SV2 2 1 SV1 3 (BLU) (WHT) SW6 SW1 SW8 SW2 CN4 CN2 (WHT) 1 (WHT) 7 1 2 LED3 21S4 SWU2 SWU1 SW5 6 1 CN51 5 (WHT) F1 1 21S4 3 (GRN) CNLVB (RED) 3 1 3 1 1 3 63L (RED) 1 1 CNDC (PNK) 1 52C 3 (BLK) 1 3 63H (YLW) 3 2 CN3D CN3S CN3N (WHT) (RED) (BLU) 1 3 1 4 1 2 2 1 63HS TH7/6 TH3 TH4 (WHT) (RED) (WHT) (WHT) CNF2 7 (WHT) 1 63H 63L 63HS TH7 TH6 TH3 TH4 NAME Terminal Block Terminal Block Terminal Block Motor For Compressor Fan Motor Solenoid Valve High Pressure Switch Low Pressure Switch High Pressure Sensor Solenoid Valve Thermistor Thermistor Thermistor Thermistor Thermistor Reactor Active Filter Module Main Smoothing Capacitor Power Circuit Board Connection Terminal Connection Terminal Connection Terminal Connection Terminal Diode Bridge Power Module Noise Filter Circuit Board Connection Terminal Connection Terminal Connection Terminal 52C Relay Controller Circuit Board Switch Switch Switch Switch Switch Switch Switch Switch Switch Switch Connector (Symbol of Board is CNLVB) SS Connector CN3D Connector CN3S Connector CN3N Connector CN51 Connector LED1,LED2 LED LED3 LED Fuse F1,F2 X501~505 Relay M-NET P.B. M-NET Power Circuit Board TP1 ConnectionTerminal X505 SYMBOL TB1 TB3 TB7 MC MF1,MF2 21S4 63H 63L 63HS SV1 TH3 TH4 TH6 TH7 TH8 DCL ACTM CE P.B. TABU/V/W TABS/T TABP1/P2/P TABN1/N2/N DS2,DS3 IPM N.F. LI/LO NI/NO EI,E2 52C C.B. SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 SWU1 SWU2 CNLVB WARNING: When the main supply is turned off, the voltage [340 V] in the main capacitor will drop to 20 V in approx. 2 minutes (input voltage: 240 V). When servicing, make sure that LED1, LED2 on the outdoor circuit board goes out, and then wait for at least 1 minute. Components other than the outdoor board may be faulty: Check and take corrective action, referring to the service manual. Do not replace the outdoor board without checking. NOTES: 1.Refer to the wiring diagrams of the indoor units for details on wiring of each indoor unit. Self-diagnosis function The indoor and outdoor units can be diagnosed automatically using the self-diagnosis switch (SW1) and LED1, LED2 (LED indication) found on the multi-controller of the outdoor unit. LED indication : Set all contacts of SW1 to OFF. [Example] · During normal operation When the compressor and The LED indicates the drive state of the controller in the outdoor unit. SV1 are turned on during cooling 8 Bit 1 2 3 4 5 6 7 operation. 1 2 3 4 5 6 7 8 Indication Compressor operated 52C 21S4 SV1 (SV2) — — Always lit When fault requiring inspection has occurred The LED alternately indicates the inspection code and the location of the unit in which the fault has occurred. OUTDOOR UNITS 2 - 15 Strainer OUTDOOR UNITS Low pressure switch (63L) Strainer Capillary tube 4-way valve Solenoid valve (SV1) Outdoor unit Indoor unit Capacity P100, P125, P140 P125, P140 P63, P80, P100 P20, P25, P32, P40, P50 Item ø 9.52 <3/8">Flare ø 9.52 <3/8">Flare ø 15.88 <5/8">Flare ø 15.88 <5/8">Flare ø 12.7 <1/2">Flare ø 6.35 <1/4">Flare Thermistor (TH3) Distributor Thermistor (TH7) Gas pipng Heatsink thermistor (TH8) Discharge thermistor (TH4) Compressor Strainer Oil separator Check valve High pressure switch (63H) Liquid piping Refrigerant pipng specifications Refrigerant Liquid pipe <3/8> Strainer Service port Stop valve Accumulator Check valve Thermistor (TH6) Refrigerant Gas pipe <5/8> Service port Stop valve Pressure sensor (63HS) Refrigerant flow in cooling Refrigerant flow in heating S Artwork (2-1 to 2-100):Artwork 24/08/2009 14:51 Page 16 5. REFRIGERANT CIRCUIT DIAGRAMS DATA G6 5. REFRIGERANT CIRCUIT DIAGRAMS PUMY-P100,125,140YHMB PUMY-P100,125,140VHMB 2 - 16 Artwork (2-1 to 2-100):Artwork 24/08/2009 14:51 Page 17 6. SOUND LEVELS DATA G6 6. SOUND LEVELS Sound level of PUMY-P140YHMB,VHMB Measurement condition PUMY-P100,125,140YHMB PUMY-P100,125,140VHMB S 90 Cooling Heating 85 80 Octave band sound level (dB) 75 Microphone 1m Unit 1.5m 70 NC-70 65 60 NC-60 55 50 NC-50 45 40 NC-40 35 30 NC-30 25 20 Approximate minimum audible limit on continuous noise 15 10 Overall Ground 63 NC-20 NC-10 125 250 500 1K 2K Octave band central frequency (Hz) 4K 8K 63Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz dB(A) Cooling 57.2 51.7 49.9 49.8 45.5 41.1 35.9 37.1 51.0 Heating 60.9 55.4 52.1 51.4 47.5 43.2 37.1 40.3 53.0 - - - - - - - - - Low Noise Mode 50/60Hz * When Low Noise Mode is set, the A/C system's capacity is limited. The system could return to normal operation from Low Noise Mode automatically in the case that the operation condition is severe. Sound level of PUMY-P100YHMB,VHMB 90 Cooling Heating 85 80 Octave band sound level (dB) 75 70 NC-70 65 60 NC-60 55 50 NC-50 45 40 NC-40 35 30 NC-30 25 20 Approximate minimum audible limit on continuous noise 15 10 Overall 63 NC-20 NC-10 125 250 500 1K 2K Octave band central frequency (Hz) 4K 8K 63Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz dB(A) Cooling 55.2 49.7 47.9 47.8 43.5 39.1 33.9 35.1 49.0 Heating 58.9 53.4 50.1 49.4 45.5 41.2 35.1 38.3 51.0 - - - - - - - - - Low Noise Mode 50/60Hz * When Low Noise Mode is set, the A/C system's capacity is limited. The system could return to normal operation from Low Noise Mode automatically in the case that the operation condition is severe. Sound level of PUMY-P125YHMB,VHMB 90 Cooling Heating 85 80 Octave band sound level (dB) 75 70 NC-70 65 60 NC-60 55 50 NC-50 45 40 NC-40 35 30 NC-30 25 20 Approximate minimum audible limit on continuous noise 15 10 Overall 63 NC-20 NC-10 125 250 500 1K 2K Octave band central frequency (Hz) 4K 8K 63Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz Cooling 56.2 50.7 48.9 48.8 44.5 40.1 34.9 36.1 50.0 Heating 59.9 54.4 51.1 50.4 46.5 42.2 36.1 39.3 52.0 - - - - - - - - - Low Noise Mode 50/60Hz dB(A) * When Low Noise Mode is set, the A/C system's capacity is limited. The system could return to normal operation from Low Noise Mode automatically in the case that the operation condition is severe. OUTDOOR UNITS 2 - 17 Artwork (2-1 to 2-100):Artwork 24/08/2009 14:51 Page 18 7. CAPACITY TABLES DATA G6 7-1. Correction by temperature CITY MULTI could have various capacities at different designing temperatures. Using the nominal cooling/heating capacity values and the ratios below, the capacity can be found for various temperatures. kW Nominal Cooling kcal/h Capacity Btu/h Input kW PUMYNominal kW Cooling kcal/h Capacity Btu/h Input kW P100YHMB P125YHMB 11.2 14.0 9,600 12,000 38,200 47,800 3.30 4.27 P140YHMB 15.5 13,300 52,900 5.32 1.4 Indoor Temperature 1.3 Ratio of cooling capacity PUMY- 1.2 22°CWB 72°FWB 1.1 20°CWB 68°FWB 18°CWB 64°FWB 1.0 16°CWB 61°FWB 0.9 Ratio of power input 1.2 1.1 22°CWB 72°FWB 1.0 20°CWB 68°FWB 18°CWB 64°FWB 0.9 16°CWB 61°FWB 0.8 0.7 0.6 0.5 0.4 -5 23 kW Nominal Heating kcal/h Capacity Btu/h Input kW PUMYNominal kW Heating kcal/h Capacity Btu/h Input kW P100YHMB P125YHMB 12.5 16.0 10,800 13,800 42,700 54,600 3.63 4.29 P140YHMB 18.0 15,500 61,400 5.32 0 32 5 41 10 15 20 25 30 35 50 59 68 77 86 95 Ratio of cooling capacity and power input 40 45 °CDB 104 113 °FDB Outdoor temperature 1.3 1.2 Ratio of heating capacity PUMY- 15°CDB 59°FDB 1.1 20°CDB 68°FDB 1.0 0.9 25°CDB 77°FDB 0.8 0.7 0.6 Indoor Temperature 1.0 Ratio of power input S 7. CAPACITY TABLES 15°CDB 59°FDB 0.9 20°CDB 68°FDB 0.8 0.7 25°CDB 77°FDB 0.6 0.5 0.4 -20 -4 -15 5 -10 -5 0 5 14 23 32 41 Ratio of heating capacity and power input OUTDOOR UNITS 10 15 °CWB 50 59 °FWB Outdoor temperature 2 - 18 Artwork (2-1 to 2-100):Artwork 24/08/2009 14:51 Page 19 7. CAPACITY TABLES Nominal Cooling kcal/h Capacity Btu/h Input kW PUMYNominal kW Cooling kcal/h Capacity Btu/h Input kW P100VHMB P125VHMB 11.2 14.0 9,600 12,000 38,200 47,800 3.34 4.32 P140VHMB 15.5 13,300 52,900 5.35 1.4 Indoor Temperature S kW 1.3 Ratio of cooling capacity PUMY- DATA G6 1.2 22°CWB 72°FWB 1.1 20°CWB 68°FWB 18°CWB 64°FWB 1.0 16°CWB 61°FWB 0.9 Ratio of power input 1.2 1.1 22°CWB 72°FWB 1.0 20°CWB 68°FWB 18°CWB 64°FWB 0.9 16°CWB 61°FWB 0.8 0.7 0.6 0.5 0.4 -5 23 Nominal Heating kcal/h Capacity Btu/h Input kW PUMYNominal kW Heating kcal/h Capacity Btu/h Input kW P100VHMB P125VHMB 12.5 16.0 10,800 13,800 42,700 54,600 3.66 4.33 P140VHMB 18.0 15,500 61,400 5.58 5 41 10 15 20 25 30 35 50 59 68 77 86 95 Ratio of cooling capacity and power input 40 45 °CDB 104 113 °FDB Outdoor temperature 1.3 1.2 Ratio of heating capacity kW 15°CDB 59°FDB 1.1 20°CDB 68°FDB 1.0 0.9 25°CDB 77°FDB 0.8 0.7 0.6 Indoor Temperature 1.0 Ratio of power input PUMY- 0 32 15°CDB 59°FDB 0.9 20°CDB 68°FDB 0.8 0.7 25°CDB 77°FDB 0.6 0.5 0.4 -20 -4 -15 5 -10 -5 0 5 14 23 32 41 Ratio of heating capacity and power input OUTDOOR UNITS 10 15 °CWB 50 59 °FWB Outdoor temperature 2 - 19 Artwork (2-1 to 2-100):Artwork 24/08/2009 14:51 Page 20 7. CAPACITY TABLES DATA G6 CITY MULTI system have different capacities and inputs when many combinations of indoor units with different total capacities are connected. Using following tables, the maximum capacity can be found to ensure the system is installed with enough capacity for a particular application. PUMY-P100,125YHMB 17.0 Capacity(kW) 15.0 13.0 11.0 9.0 Input(kW) 7.0 4.0 2.0 P100 Cooling Heating P125 Cooling Heating 0.0 40 60 80 100 120 140 160 180 Total capacity of indoor units PUMY-P140YHMB 19.0 Capacity(kW) 17.0 15.0 13.0 11.0 9.0 Input(kW) S 7-2. Correction by total indoor 4.0 2.0 P140 Cooling Heating 0.0 60 80 100 120 140 160 180 200 Total capacity of indoor units OUTDOOR UNITS 2 - 20 Artwork (2-1 to 2-100):Artwork 24/08/2009 14:51 Page 21 7. CAPACITY TABLES DATA G6 PUMY-P100,125VHMB S 17.0 Capacity(kW) 15.0 13.0 11.0 9.0 Input(kW) 7.0 4.0 2.0 P100 Cooling Heating P125 Cooling Heating 0.0 40 60 80 100 120 140 160 180 Total capacity of indoor units PUMY-P140VHMB 19.0 Capacity(kW) 17.0 15.0 13.0 11.0 Input(kW) 9.0 4.0 2.0 P140 Cooling Heating 0.0 60 80 100 120 140 160 180 200 Total capacity of indoor units OUTDOOR UNITS 2 - 21 Artwork (2-1 to 2-100):Artwork 24/08/2009 14:51 Page 22 7. CAPACITY TABLES DATA G6 CITY MULTI systems can have extended piping lengths if certain limitations are followed, but cooling/heating capacity could be reduced. Using following correction factor by equivalent piping length shown at 7-3-1 and 7-3-2, capacity can be found. 7-3-3 shows how to obtain the equivalent piping length. 7-3-1. Cooling capacity correction PUMY-P140YHMB,VHMB PUMY-P100YHMB,VHMB 1 0.95 Tota l 0.9 Cooling capacity correction factor Cooling capacity correction factor 1 0.95 cap acit y of indo or u 0.85 nit 0.8 Tot a l ca 0.8 pac ity of i ndo or uni t 0.75 0.7 0.65 0.9 0.85 0.75 0 10 20 30 40 50 60 Piping equivalent length (m) 70 0.7 0.65 80 0 10 20 30 40 50 60 Piping equivalent length (m) 70 80 PUMY-P125YHMB,VHMB Cooling capacity correction factor 1 0.95 Tot a l ca 0.9 pac 0.85 ity of i ndo or u 0.8 nit 0.75 0.7 0.65 0 10 20 30 40 50 60 Piping equivalent length (m) 70 80 70 80 7-3-2. Heating capacity correction PUMY-P100,125,140YHMB,VHMB 1 Heating capacity correction factor S 7-3. Correction by refrigerant piping length 0.95 0.9 0.85 0.8 0.75 0.7 0.65 0 10 20 30 40 50 60 Piping equivalent length (m) 7-3-3. How to obtain the equivalent piping length 1. PUMY-P100, 125, 140YHMB, VHMB Equivalent length = (Actual piping length to the farthest indoor unit) + (0.30 x number of bends on the piping) m OUTDOOR UNITS 2 - 22 Artwork (2-1 to 2-100):Artwork 24/08/2009 14:51 Page 23 7. CAPACITY TABLES DATA G6 7-4. Correction at frost and defrost Table of correction factor at frosting and defrosting Outdoor inlet air temp. °C Outdoor inlet air temp. °F PUMY-P100, 125, 140YHMB PUMY-P100, 125, 140VHMB 6 43 1.0 1.0 4 39 0.98 0.98 2 36 0.855 0.855 1 34 0.85 0.85 0 32 0.845 0.845 -2 28 0.89 0.89 -4 25 0.90 0.90 -6 21 0.95 0.95 -8 18 0.95 0.95 -10 14 0.95 0.95 -20 -4 - 7-5. Operation temperature range • Cooling Indoor temperature °FWB°CWB 86 30 77 25 68 20 59 15 50 10 41 5 -20 -4 -15 5 -10 14 -5 23 0 32 5 41 10 50 15 59 20 68 25 77 30 86 35 95 40 104 45 113 50 122 °CDB °FDB Outdoor temperature * 10 to 40°CDB (50 to 115°FDB): in case of connecting PKFY-P15/P20/P25 type indoor unit. • Heating Indoor temperature °FDB °CDB 86 30 77 25 68 20 59 15 50 10 41 5 -20 -4 -15 5 -10 14 -5 23 0 32 5 41 10 50 15 59 20 68 25 77 30 86 35 95 40 104 45 113 50 122 °CWB °FWB Outdoor temperature OUTDOOR UNITS 2 - 23 S Due to frost at the outdoor heat exchanger and the automatical defrosting operation, the heating capacity of the outdoor unit should be considered by multiplying the correction factor which shown in the table below. Artwork (2-1 to 2-100):Artwork 24/08/2009 14:51 Page 24 8. OPTIONAL PARTS DATA G6 8-1. JOINT CITY MULTI piping can be easily installed with joints and headers provided by MITSUBISHI ELECTRIC CORP.. There is one set of piping joints. Details for installing the joint sets are found in System Design 3, or their own Installation Manual. CMY-Y62-G-E mm 1. Specification 45 83 Pipe cover (External view : 83X81X44) Inner Diameter 81 100 9.52 Reducer (Accessory): B 9.52 Note) Connection only to downstream units Inner Diameter 9.52 A (Inner Diameter) 12.7 19.05 80 B (Outer Diameter) 9.52 15.88 Inner Diameter 19.05 C (Inner Diameter) 6.35 12.7 12.7 15.88 Outer Diameter 80 75 107 Pipe cover (External view : 75X100X44) Inner Diameter 19.05 1 15.88 Note) Connection only to downstream units C Inner Diameter Number of reducers 2 1 19.05 22.22 For gas pipe: Outer Diameter Inner Diameter 80 105 40 D 2. External drawing For liquid pipe: A Accessory Inner Diameter Main Details 2 ports One for each liquid and gas pipe Phosphorus deoxidized copper C1220T-OL (JIS H3300) Foamed polyethylene (one for each liquid and gas pipe) 10 reducers of 7 types (Refer to the external drawing for details.) Inner Diameter Items Number of ports Number of branch joints Pipe material Insulation material Reducer 50 S 8. OPTIONAL PARTS 80 D (Outer Diameter) 9.52 15.88 19.05 19.05 Number of reducers 2 1 1 2 150 100 OUTDOOR UNITS 2 - 24 Artwork (2-1 to 2-100):Artwork 24/08/2009 14:51 Page 25 8. OPTIONAL PARTS DATA G6 8-2. HEADER CMY-Y64-G-E mm 1. Specification Items Number of ports Number of branch joints Pipe material Insulation material Reducer Cap Main Accessory Details 3 ~ 4 ports One for each liquid and gas pipe Phosphorus deoxidized copper C1220T-OL (JIS H3300) Foamed polyethylene 7 reducers of 5 types 2 caps of 2 different types for each liquid and gas pipe 4 caps in total 2. External drawing For liquid pipe: Reducer (Accessory): 9.52(Inner Diameter) A 12.7(Inner Diameter) B 350 80 B B B Dimension table B A Symbol A 60 For gas pipe: 60 60 A 50 B Number of reducers 1 2 6.35 2 9.52 6.35 9.52 360 22.2(Inner Diameter) 80 19.05(Inner Diameter) C (Inner Diameter) 15.88 9.52 69 20 D (Outer Diameter) 19.05 12.7 15 129 B (Outer Diameter) 15.88 12.7 C 60 Inner Diameter (mm) A (Inner Diameter) 19.05 15.88 D 114 10 59 10 D Dimension table D D D C Symbol C 60 Number of reducers 1 1 60 C 60 60 D 60 Inner Diameter (mm) 12.7 15.88 CMY-Y68-G-E mm 1. Specification Items Number of ports Number of branch joints Pipe material Insulation material Reducer Cap Main Accessory Details 5 ~ 8 ports One for each liquid and gas pipe Phosphorus deoxidized copper C1220T-OL (JIS H3300) Foamed polyethylene 3 reducers of 3 types 3 caps for each liquid and gas pipe 6 in total 2. External drawing For liquid pipe: Reducer (Accessory): 60 A B A 60 60 A B A 60 555 60 B A 60 60 80 Dimension table 75 Symbol A B A (Inner Diameter) 19.05 12.7 B (Outer Diameter) 15.88 9.52 Number of reducers 1 1 Inner Diameter (mm) 6.35 9.52 C For gas pipe: D B A A 55.6 115.6 156 A B 52 622 12.7(Inner Diameter) A Insulation material (Accessory) 80 Insulation material (Accessory) 22.2(Inner Diameter) 19.05(Inner Diameter) C (Inner Diameter) 15.88 C C D C 60 60 63.8 128.8 156 52 622 C C D D D C C C 60 60 60 600 60 60 Number of reducers 1 Dimension table Symbol 120 D (Outer Diameter) 19.05 C D OUTDOOR UNITS Inner Diameter (mm) 12.7 15.88 2 - 25 S CITY MULTI piping can be easily installed with joints and headers provided by MITSUBISHI ELECTRIC CORP.. There are two sets of headers for piping. Details for installing the header sets are found in System Design 3, or their own Installation Manual. Artwork (2-1 to 2-100):Artwork 24/08/2009 14:51 Page 26 DATA G6 2 - 26