Preview only show first 10 pages with watermark. For full document please download

Pxi Module Map - Microwave Journal

   EMBED


Share

Transcript

HIGH DENSITY 46 9 Features Configurations Relay Type 40-110/120 40-125 40-140A/141 40-142 40-143 40-145 l Medium Power 40-146 40-148 16 or 32 x SPDT 16 or 32 x 16 or 24 x 50, 75 or 100 x 50 x 48 or 50, 75 or 25 or 32, 48 or 16 x Shielded SPST 16 or Shielded SPST or 50 x Shielded 64 x 100 x SPST 50 x or 64 x SPDT 24 x DPST SPST DPST SPST SPDT (NO or NC) DPST SPDT Pickering Instrumentation Reed Max Switch Voltage Max Switch/Carry Current 40-115 Pickering Instrumentation Reed 150VDC/100VAC 0.25A/1A 1A 40-132 8 or 13 x DPDT 16 or 16 or 16 or 16, 25 12, 16 16 32 or 26 x 32 x 19 x or 32 or 19 x 39 x SPDT SPST DPST x SPST x DPST SPST SPST 40-136 Electro-mechanical 40-137 40-138 40-139 80xSPST, 40x DPST, 52xSPDT or 26xDPDT 60-103B, 18-Slot LXI Modular Chassis Both chassis now feature front panel display of IP address Electro-mechanical 110VDC/ 250VAC 200V 2A 1 Mix of SPST, DPST, SPDT & DPDT Relays Pickering Reed 300VDC/250VAC 1A 1 3 l High Density l Versatile Mixed l Low Cost Version Power Relay Relay Configs of 40-138 l Power Reed Relays 40-131 220VDC/ 125VAC 0.25A/1A 6 l Low Cost Relay For Medium Power 40-130 Electro-mechanical 150VDC/100VAC 1A/1.2A 6 2 l Pin Compatible With 40-140A/141/143 1A/2.5A or 1A/2A 300VDC/250VAC 5A 4 relays, microwave relays and programmable resistors as shown above. This gives the user enormous flexibility to define a switching/ T&M system which exactly meets their requirements. All of the modules illustrated are compliant to the PXI architecture and therefore can also be used in any PXI or PXIe Hybrid chassis. For example, a 60-103B chassis can be fitted with a combination of high density relay modules, matrix modules, multiplexers, power Features Model Family 40-150/151 40-155/156 l High Power l High Density l SPST or DPST l High Current 8 or 12 x DPST 8 or 16 x SPDT 125VDC/ 250VAC 35VDC/ 250VAC Configurations 10 x DPST l Very High Power l 50A Peak l Suitable For Automotive Test Current Max Switch/Carry Current 10A 2 l High Voltage Reed Relays 3 l High Voltage Power Relays 40-161 40-170 40-180 40-181 40-182 40-183 40-310 40-330 2 x SPST or 2 x DPST 2 or 4x SPST 2x SPDT 3 or 6 x SPST 6 x SPST 8 or 16 x SPST 12, 18 or 24 x SPST 125VDC/ 250VAC 5A 3 l 120A Peak Current 10, 12, 16 x SPST or 6, 12 x SPDT Electro-mechanical Max Switch Voltage 2A Rhodium Reed Electromechanical Solid State 300VDC/ 250VAC 30VDC/ 270VAC 14VDC or 28VDC 200VDC/ AC peak 40VDC/ AC peak 16A 30A 20A or 40A 10A 40A 8A 1000VDC/1000VAC peak 0.5A 5A 40-510/511/512/513 40-515/516/517 40-505 40-506 40-507 40-508 40-509 Configurations Single 8x8, 16x4 or Dual 8x4, 2-Pole Single 42x4, 1-Pole Single 32x6, 1-Pole Single 25x8, 1-Pole Single 18x12, 1-Pole Single 14x16, 1-Pole Instrumentation Reed Electro-mechanical 150VDC/100VAC 300VDC/250VAC 1A/1.2A 2A Max Switch/Carry Current 3 40-521 40-522 40-523/524 40-525 40-527 40-528A 40-529A Single 16x8 or 32x4, 2-Pole Dual 12x8, 1 or 2-Pole or 1-Pole Shielded Single 44x4, 1-Pole, 2-Pole, 1-Pole Shielded or 46x4, 1-Pole Single 32x4, 1-Pole Matrix With Switched Loop-Thru Single 64x2, 1-Pole Single 32x4 1-Pole Single 16x8, 1-Pole 40-500 40-501 Single 32x8, 1-Pole Electro-mechanical 300VDC/250VAC 60V 100V 2A 0.5A 0.15A 1A/ 1.25A 40-530 Single 64x4, 1-Pole 150VDC/100VAC 0.5A/1A 2 l Ultra High Density l 256 Crosspoints Pickering Instrumentation Reed 300VDC/250VAC 1 l Fast Operate Time l Long Service Life Single 24x8, 1 or 2-Pole or 1-Pole Shielded 2A 1 1 l 2A Maxtrix l 128 Crosspoints 40-518A/519A Electro-mechanical 150VDC/100VAC Solid State 11 4 3 l Ultra High Density l 1-Pole Shielded Reed Version Available 40-533A 40-531/532 Single 64x4 1 or 2-Pole Single 32x8 or Dual 16x8, 1 or 2-Pole Instrumentation Reed l Highest Density in 1-Slot l 528 Crosspoints 1 4 l Ultra High Density 40-534A 40-538 40-535/536/537 40-540 40-541 40-542 40-575 40-576 40-577 40-578 40-579 Dual 32x4, 1 or 2-Pole Single 55x8, 1-Pole Single 92x4, 44x8, Shielded 44x8 or Dual 44x4, 1-Pole Single 132x4, 1-Pole Single 66x8, 1-Pole Single 33x16, 1-Pole Single 85x4, 1-Pole Single 66x6, 1-Pole Single 50x8, 1-Pole Single 36x12, 1-Pole Single 28x16, 1-Pole Pickering Instrumentation Reed 1 5 l Highest Density Single Slot 3U 2 Amp Matrices l Up To 448 Crosspoints l High Density l 2 Amp 40-582 40-584 40-585 40-586A 40-587A 40-545/546/547/548 40-549 Single 33x8, 2-Pole Single 16x16, 2-Pole Single 128x2, 1-Pole Single 64x4, 1-Pole Single 32x8, 1-Pole Single 16x16, 1-Pole Single 10x4, 10x8, 20x4 or Dual 10x4, 1-Pole Single 16x4, 8x8, 8x4 or Dual 8x4, 1-Pole Electro-mechanical 300VDC/250VAC 2A 1A 2A Features 9 1 16 l Low Density, Low Cost l Differential Thermal l Low Cost l Single and Dual Configs Offset <1.5µV l 2A Switching 24 l Very High Density l Wide Range of Configurations 40-630/632 40-620 40-635 Configurations Between Single 64:1 1-Pole, & Single 16:1 4-Pole Single 23:1 1-Pole Low Thermal EMF MUX Between Single 64:1 1-Pole & 4-Bank 8:1 2-Pole Between Single Between Single 128:1 1-Pole & 160:1 1-Pole & 8-Bank 8:1 2-Pole 20-Bank 4:1 2-Pole Electro-mechanical Pickering Instrumentation Reed Max Switch Voltage Pickering Instrumentation Reed 40-610 2 2 l Multiple Configs l Configurable l High Speed, Long Life l Equivalent to 40-612 Model Family Relay Type 40-615 40-680 40-682 Between Single 160:1 1-Pole & 20-Bank 8:1 1-Pole 40-683 40-616 40-617 Solid State 100V 300VDC/250VAC 150VDC/100VAC 15V 40V 100V 100V 0.5A/1A 2A 1A/1.2A 20mA 250mA 125mA 1A 2 1 l High Density l Low Cost 40-670A Single 94:1 1-Pole or 47:1 2-Pole Pickering Reed 1A/1.2A l Wide Range of Configurations 40-640 Between Single 128:1 16-Bank 18-Bank 1-Pole & 8-Bank 8:1 5:1, 3:1, 2-Pole 1-Pole 1-Pole 6 16 l Configurable with l High Density inter-bank relays 150VDC/100VAC Max Switch/Carry Current 2 Between Single 198:1 1-Pole & Single 5:1 32-Pole 29 29 l High Density MUX in Pickering BRIC format 1 l Power MUX in Pickering BRIC format l 5A Power MUX 6 1 l High Density l 5A Power MUX 1 4 l Configurable l High Density l High Density l 2-Pole Switching l 2-Pole Switching l 1-Pole Switching 1 l Power & Sense MUX l High Density l 2-Pole 40-613 40-570 40-571 40-650 40-651 40-655 40-656 40-657 40-658 40-659 Single 158:1 1-Pole or Single 79:1 2-Pole 8 Basic Configs from Single 128:1 1-Pole to 8-Bank 8:1 2-Pole 5 Basic Configs from Single 64:1 2-Pole to 16-Bank 4:1 2-Pole Max. config. between 6:1 160-Pole & 96:1 10-Pole with switched loop-thru Max. config. between 6:1 48-Pole & 48:1 6-Pole with loop-thru Single 16:1, 2-Pole 48:1, 2-Bank 24:1, 4-Bank 11:1 or 8-Bank 5:1 1-Pole 7-Bank 4:1, 2-Pole Single 38:1, 2-Pole 8-Bank 8:1, 4-Bank 16:1, 2-Bank 32:1 or Single 64:1 Dual 18:1, 2-Pole 8-Bank 8:1, 2-Pole 150VDC/100VAC Electro-mechanical 300VDC/250VAC 1A 100VDC/100VAC peak 2A 1A 125VDC/250VAC 110VDC/250VAC 3A Instrumentation Reed 220VDC/125VAC 5A 110VDC/250VAC l 1 or 2-Pole Power MUX l 10A or 8A Current Handling 40-660 Single 10:1, 1-Pole 2 l High Speed, Long Life l High Inrush Current l High Voltage l Hot Switch 750V 40-665 Single 10:1, 2-Pole 40-666 Single 18:1, 1-Pole Electro-mechanical 200VDC/240VAC 300VDC/250VAC 1A/2A 2A 2A 4 3 1 40-612 Electro-mechanical 0.5A Features 8 l Terminated Channels l High Performance l High Performance l Low Cost 40-880 Model Family Impedance 40-870 Dual, Quad, Hex or Octal SPDT Max Frequency 6GHz l High Density l Low Cost 40-710 75Ω 75Ω 1 to 2.5GHz 1.2GHz 2 125VDC/250VAC 10A 8A 10A 40-877 40-837 50Ω 40-750 75Ω 4 50Ω Single or Dual 2x2 8x2 6GHz 2.5GHz 1.5GHz l Low Loss Expansion Options l X and Y Isolation Switching 40-726A 40-727/728/729 75Ω 50Ω 8x9 500MHz 12 l Easy Y-Axis LoopThru 40-725 Single 4x4 500MHz l X and Y Isolation Switching 75Ω 50Ω 12x8 250MHz 300MHz 2 4 l Terminated Channels l High Performance 40-881 300MHz 12 l High Performance l Low Cost 40-882 75Ω 40-872 1x or 2x SP6T Terminated 100MHz 4 l Terminated Channels 40-832 50Ω 16x4, 16x2 or 8x4 250MHz 6 Single 12x2 or 6x4, 1-Pole Electro-mechanical 40V 1000VDC/AC peak 10A 40A 5A BRIC™ Matrix Modules BRIC Matrix Modules 40-667 6 100+ l High Voltage 1-Pole Power MUX 40-331 Single 6:1 or Dual 3:1, 1-Pole Single 12:1 or 24:1 1-Pole Single 24:1, Dual 12:1, Quad 6:1, Hex 4:1, Octal 3:1 or Twelve 2:1 Solid State Rhodium Reed Electro-mechanical 40V 10A 40A 1000VDC/1000VAC peak 0.5A Features 40-560A Model Family 40-320 200V 100+ l Integrated PXI Matrix With Built In High Perfomance Bus l Highest Quality Reed Relays 40-561A Configurations Pickering Instrumentation Reed Relay Type 40-562A 40-563A Pickering Instrumentation Reed (1-pole available with shielded reed) Max Switch Voltage 5A l Available as 2, 4 or 8 Slot PXI Modules l x4, x8, x16 & x32 Options 184x4 to 92x8 to 46x16 to 60x8 to 30x16 to 88x4 to 44x8 to 22x16 to 1104x4, 552x8, 276x16, 360x8, 180x16, 528x4, 264x8, 132x16, 1-Pole 1-Pole 1-Pole 1, 2-Pole 1, 2-Pole 1, 2-Pole 1, 2-Pole 1, 2-Pole 10x32 to 60x32, 1-Pole 64x8 to 384x8, 1-Pole Instrumentation Reed Solid State 150VDC/100VAC Max Switch/Carry Current 40V 0.5A 1A/1.2A 0.25A 2A Matrix Modules BRICBRIC™ Matrix Modules 92 2A SCALABLE MATRIX MICROWAVE SWITCHING 1x, 2x, 3x or 4x SP4T Terminated 1x, 2x or 4x SP4T 8 l 3GHz Bandwidth l Terminated Com. 40-873 40-874 50Ω 1x or 2x SP4T Terminated 1x, 2x or 4x SP4T Terminated 6GHz 4 18 l High Performance l Low Cost 40-876 75Ω 40-834 40-875 40-835 40-740/745/746 75Ω 50Ω 75Ω 50Ω or 75Ω 1x or 2x SP8T Fault Insertion Modules 12 l Up to 2GHz Bandwidth l Wider Choice of l Wide Connector Choice Connector Types 1x SP16T l Wider Choice of Connector Types 40-747/748/749 50Ω 4 4 l Very High Density l Low Cost 40-778 75Ω 50Ω l Choice of Bandwidths l Choice of Connector Types 40-755 75Ω 12 30 40-780 50Ω 50Ω l Extended Life & Low Cost Options l Faster Operate Time 40-782 75Ω l Remote Mount Versions l Terminated Options Dual SP8T 4 or 10off SP4T 5 or 10off SP4T Single, Dual, Triple or Quad SPDT Single or Dual Transfer Switch 1GHz to 2GHz Up to 2GHz 2GHz 1.8GHz 500MHz Up to 65GHz Up to 40GHz 40-786 75Ω Single or Dual SP6T & SP4T OPTICAL SWITCHING 6GHz, 18GHz, 26.5GHz, 40GHz Up to 40GHz 4GHz TELECOMS/DIFFERENTIAL SWITCHING 22 l High Density 2-Pole Matrix l 60W Switching Features 40-565A 40-566A 40-568 40-596 40-567 Configurations 24 to 192x8 2-Pole 55 to 385x4 2-Pole 75 to 600x4 1-Pole 58 to 464x6 1-Pole 44 to 352x8 1-Pole Relay Type 40-597 40-598 32 to 256x12 24 to 192x16 1-Pole 1-Pole Electro-mechanical Max Switch Voltage 20GHz l Available as 2, 4 or 8 Slot 3U PXI Modules Model Family 200VDC/140VAC 100VDC/70VAC Max Switch/Carry Current 2A Amplifier & Attenuator Modules 83 ARINC 608A 70 l Very High Density 1-Pole Matrix l x4, x6, x8, x12 & x16 Options USB Switch 15 PROGRAMMABLE ATTENUATORS N 20 EW 13 FAULT INSERTION SWITCHES 50Ω Single, Dual or Triple SP6T MUX USB, Avionics Switch Modules USB,Communications Communications & Avionics& Switching Modules 56 l 20GHz Bandwidth 40-785A 50Ω 1xSP16T 2xSP8T or 4xSP4T 3 35 40-784 SP4T, SP8T, 2xSP4T or SP4T Terminated 3GHz Fault Insertion Modules FAULT INSERTION MATRICES Single 8x2, 1-Pole N 20 EW 13 RF MULTIPLEXER 3 l Expandable l Expandable l High Performance 40-884 9 or 17 x SPDT 1 to 2GHz 8 40-332 200V 10A N 20 EW 12 l High Performance l Compact 50Ω Quad SPDT 2.7GHz 1 40-754 50Ω Triple or Hex SPDT 3GHz 4 l Multiple Connector Options 40-830 50Ω Configurations 7 5A 213 RF MATRIX N 20 EW 12 4 Single 6x2, 1-Pole 40-555 HIGH DENSITY SCALABLE MATRIX RF & Microwave SwitchModules Modules RF & Microwave RF SPDT SWITCH 40-554 Solid State HIGH VOLTAGE 40-611 Pickering Instrumentation Reed 0.5A/1.2A 1 l Versatile - Many Possible Configurations l Software Configurable 40-675 40-553 2 l High Voltage Power Matrix N 20 EW 13 N 20 EW 12 7 Single 8x4, 2-Pole 3 l High Speed, Long Service Life l High Inrush Current 125VDC/250VAC 2A HIGH POWER MUX N 20 EW 13 N 20 EW 13 10 40-551 Single 8x4, 8x2 or 4x4 1-Pole (8x4 loop-thru option) 187 HIGH DENSITY MUX 1 l High Density l 10 Amp 40-550 110VDC/250VAC Multiplexer Modules Multiplexer Modules LOW DENSITY MUX 2 l 2-Pole l 5 Amp Electro-mechanical 150VDC/100VAC 0.5A 4 l High Density l 5 Amp 40-581 Pickering Instrumentation Reed 1A 4 l Highest Density 1-Slot 2 Amp Matrices HIGH VOLTAGE N 20 EW 12 N 20 EW 12 N 20 EW 13 1 l FlexBus Architecture l X and Y Loop-Thru l Reed Relay Matrix Single 12x4, 12x8, 24x4 or Dual 12x4, 1 or 2-Pole or 1-Pole Shielded Relay Type 10 l 2A Matrix With up to 224 Crosspoints Model Family Max Switch Voltage 2 5 HIGH POWER (2 Amp to 40 Amp) N 20 EW 13 HIGH DENSITY (256 to 528 Crosspoints) N 20 EW 13 3 l 2-Amp l 2-Pole l Reed Relay Matrix 86 MEDIUM DENSITY (128 to 256 Crosspoints) N 20 EW 13 LOW DENSITY (<128 Crosspoints) Features 34 Features l High Density Fault Insertion Breakout Matrix l Available With 2 or 3 Pin Breakout 40-592A Dual 31x4 to Dual 124x4 Fault Matrix, 2-Pin Breakout Dual 6x4 to Dual 30x4 Fault Matrix, 3-Pin Breakout 74, 64 or 32 Channels, 1 or 2 Fault Bus (4 or 8 Fault Input) 6 Signal Channels, 2 Fault Buses (2 Fault Inputs) Electro-mechanical Electro-mechanical Solid State 150VDC/100VAC 125VDC/250VAC 165VDC/115VAC 40VDC/AC pk 200VDC/AC pk 1A/1.2A 10A(matrix) 8A(breakout) 2A Dual 20x4 to Dual 80x4 Fault Matrix, 3-Pin Breakout Dual 20x4 to Dual 160x4 Fault Matrix, 3-Pin Breakout Pickering Instrumentation Reed Max Switch Voltage Max Switch/Carry Current 40-191 40A 40-192 2 2 40-193 40-194 7 Signal Channels, 1 or 2 Fault Buses (1 or 2 Fault Input) 40-195 40-196 22 or 11 Signal Channel Pairs, 8 or 4 Fault Inputs 2 2 l 1A - For Avionics l 5A - For Avionics l 2A - High Density /Automotive /Automotive l Low Cost l High Power 40-190B Dual 31x4 to Dual 248x4 Fault Matrix, 2-Pin Breakout Relay Type l High Density 4 2 l High Power l High Inrush Current Rating 40-595A Model Family Configurations 6 l Power Fault Insertion Breakout Matrix l 5A - High Density l Low Cost 40-197 2 l 10 Amp l High Density 40-198 10 or 5 Signal 34 or 16 Signal 20 Signal Channels, Channel Pairs, 10 Channels, 4 Fault 1 or 2 Fault Buses or 5 Fault Inputs Buses (8 Fault Inputs) (3 or 6 Fault Input) 10 Signal Channels, 1 or 2 Fault Buses (1 or 2 Fault Input) 10A 16VDC 20A (1A min) 150VDC/100VAC 110VDC/100VAC 300VDC/250VAC 110VDC/250VAC 125VDC/250VAC 1A 5A 2A 5A 10A 20A Features Model Family Configurations Number of Channels Resolution l Fixed Value Resistor Modules l User Specified Values 40-280 40-281 40-282 Fixed Value Dual Fixed Value Selectable Selectable Potential Resistors Resistors Divider 24 or 48 12 or 24 ─ Accuracy User Specified Resistance Range User Specified 12 or 24 l Additional Relay Option to Extend Resistance Range 40-290 40-291 Programmable Resistor 8 l Up to 15W l High Density Programmable Resistor Resistor Load l Custom Options Available 8 l High Density Potentiometer Module l Custom Options Available 40-295 Programmable Load Resistor 40-296 Programmable Resistor 1 40-260 Programmable Potentiometer 1 10 or 18 5 or 10 5 or 10 3 or 6 5 or 9 2 or 4 2 or 4 1 or 3 3 16-Bit 8-Bit 8-Bit 8-Bit 12-Bit 16-Bit 24-Bit 8-Bit 12-Bit 16-Bit 24-Bit <10mΩ 0.5Ω to 32kΩ 0.5Ω to 128Ω 40Ω to 295Ω, 10Ω to 2.56kΩ ±0.5% (±1% >1MΩ) 0 to 255Ω 0 to 4kΩ 0 to 65kΩ ±0.5% (±1% >1MΩ) 0 to 16MΩ 0 to 255Ω 0 to 4kΩ 0 to 65kΩ 0.1% 0 to 16MΩ 40-261 90Ω to 8kΩ PT100 RTD Simulator PT1000 RTD Simulator Strain Gauge Simulator <15mΩ <8mΩ 10Ω to 36kΩ 6 <90mΩ 0.1% 90Ω to 250Ω 900Ω to 2500Ω <2mΩ <25mΩ 0.03% 0.06% 350Ω Bridge 3kΩ Bridge High Density Precision Programmable Resistor 18 9 6 1Ω 0.25Ω 0.125Ω Resolution ±0.2% 1Ω to 230Ω 2Ω to 13.5kΩ 3Ω to 1.5MΩ 2 Features 40-852 40-855 40-860 40-792/793 40-795/796 40-735 40-736 40-569 40-618 40-737 Model Family Configurations 8-Channel MUX 2-Channel MUX Insert/Bypass Switch 1-Pole (75Ω) 8 or 16-Channel 2-Pole (100/120Ω) 8 or 16-Channel Single 36, Dual 18 or Single 18 Channel 8-Ch/4-Pair, 16-Ch/2-Pair & 32-Ch/1-Pair Resource Distributor & Bus Matrix Inputs Switch 12off 4-Channel MUX & 44 x SPST Single 8 or 16-Channel 4-Pole Configurations MEMS Optical Electro-mechanical Reed & Electro-mechanical Electro-mechanical Max Switch Voltage ─ 100VDC/100VAC 150VDC/100VAC 100V Max Switch/Carry Current ─ 1A 0.5A 0.3A Electro-mechanical 220VDC/250VAC 2 Configurations Number of I/P Channels Input Channel Type Number of O/P Channels Output Channel Type l Suitable for Driving Logic or Relay Coils 40-410 1 l Internal or External Relay Supply 40-411 PROTOTYPING MODULES 2 l Programmable Threshold 3 l 2A Output Drivers l Programmable Threshold 40-412 40-413 4 l Suitable for Industrial Automation Applications 300VDC/250VAC 40-490 40-491 40-485 Automotive Switch Simulator Dual Automotive Switch Simulator 32 ─ ─ Number of Channels TTL ─ ─ Input Voltage 32 32 ─ High Side FET Switch +40V Maximum Voltage Up to 400mA Per Channel TTL ─ ─ 32 16 TTL ─ 0.3V to 50V Threshold 32 64 TTL or Open Collector 60V Drive Capability Up to 1A Per Channel High or Low-Side Drivers (2A source, 2A sink) Features 40-480 32 6V Threshold TTL 8, 16 or 32 Single or Dual, 8 or 16 Leaky or Dirty Switch Simulation 3 or 6 41-180 1 or 2 Maximum Attenuation or Amplification 31.75dB per channel 100dB or 60dB per channel 41-661 41-650 High Voltage Attenuator 1 or 2 10 single 5 l Up to 60V peak-topeak output l 600V input rating 41-660 RF Attenuator 10MHz to 6GHz 36 40-225A Digital Input/Output Module With Programmable Threshold 32 l Simulates Leaky or Dirty Switch Contacts in Automotive Test Applications Breadboard Module Without Digital I/O Relay Driver Module 41-183 Solid State RF Attenuator 2 5 diff. High Voltage Amp Up to 5 DC to 3GHz DC to 20kHz DC to 1MHz 63dB per channel 160 times per channel 20 times POWER SUPPLIES 40-220A Digital Input/Output Module 41-182 Number of Channels 4 3 2 l High Linearity & True DC Coupling Frequency Range SWITCH SIMULATORS l Prototyping Area l With or Without Digital Input/Output 4 l Long Service Life l Long Life, Fast Operation & Fast Operation l External Triggering Power Supply & Battery Simulator Modules Power Supply & Battery Simulator Modules Breadboard Module With Digital I/O Optically Isolated Digital I/O Module With or Without On Board DC-DC Converter High or Low-Side Drivers (0.4A source, 0.5A sink) 100V 0.5A data, 2A power 24 4 1 Electro-mechanical 2A Digital Prototyping & Switch Digital I/O,I/O, Prototyping & Switch Simulator ModulesSimulator Modules Model Family 40-297 2 l Data Comms MUX For USB1 or USB2 40-850 Features l Simple Software Control l Short & Open Simulation l Source Switch l For ARINC 608A 4-Channel MUX 3 40-265 6 or 18 ±0.08% ±70mΩ 1.5Ω to 2.9kΩ l Emulates Resistive Strain Gauge Bridge Circuits 40-262 2 <2mΩ 2 1 17 l Multiple Configurations in BRIC Format Model Family DIGITAL I/O MODULES 4 l Emulates RTDs l High Accuracy, Fine Resolution Precision Programmable Resistor 4 5% ±0.5Ω 2 l Very High Accuracy and Stability l Fine Setting Resolution 2 0.5% 1 l Data Comms MUX For AFDX, Ethernet, LVDS, USB & RS232 PRECISION RESISTOR MODULES 2 40-292 6 l Data Comms MUX For Switching USB and RS232 40 RESISTOR MODULES 4 6 l Tributary Switches l Suitable for Telecoms Test Applications Relay Type Electro-mechanical Programmable Resistor Modules Programmable Resistor Modules 6 Features 40-199 50 l Long Operating Life With High Repeatability l Modules Available With Single-Mode or Multi-Mode Support l Up to 4 Fixed Voltage Outputs Model Family 41-720 Configurations Isolated Fixed Voltage Power Supply Output Voltage Max Current 1 1 l Dual Positive Outputs l Non-Isolated l Dual Negative Outputs l Non-Isolated 41-735 41-736 Programmable Voltage Power Supply Up to 4 41 BATTERY SIMULATORS 41-743 Isolated Programmable Power Supply 1 l Ideal For Battery Stack Emulation 41-752 1 l Simulate Power Supplies of Cellular Phones & Other Portable Battery Devices 41-753 Variable voltage source with current source and current sink 1 6 1 +5V from PXI backplane +12V from backplane or external supply -12V from backplane or external supply +5V from two PXI backplane slots +3.3V, +5V & ±12V from PXI backplane +5V from PXI backplane 3.3V, 5V, 12V or 15V Adjustable 0 to +10V Adjustable 0 to -10V Adjustable 0 to 48V Adjustable 0 to 7V Stackable to 700V Adjustable 0 to 6V 2A (up to 20V) 300mA Source 100mA Sink 2.8A Source 0.5A Sink 4A (3.3V option) 2 1 l High Accuracy & Low Noise l Remote Sense 1A per Channel pickeringtest.com Pickering Interfaces 40-160 10 or 20 x SPST Relay Type For more information go to www.pickeringtest.com/lxi/ 8 6 3 l High Power l DPST and SPDT MatrixMatrix Modules Modules 12 pickering 29 HIGH VOLTAGE Pickering Interfaces Model Family 11 7 l Highest Density Reed PXI Module l Shielded Versions Available HIGH POWER (5 Amp to 40 Amp) Over 600 modules available from Pickering are supported by the LXI Modular Chassis. They range from general purpose relays, matrices, multiplexers and RF switches to special switching functions such as fault insertion and serial communications. Also supported are a selection of T&M modules such as programmable resistors, digital I/O, power supplies, battery simulators and attenuators. Select the modules you require to be remotely controlled via Ethernet from the tables shown. 60-102B, 7-Slot LXI Modular Chassis l Low Cost General Purpose Switching l Uses High Reliability Reed Relays HighGeneral Power & High Voltage Relay Modules Purpose Relay Modules The 60-102B and 60-103B LXI Modular chassis are capable of hosting Pickering's extensive range of Switching and Test & Measurement modules in an LXI environment, allowing remote control over a gigabit Ethernet connection. MEDIUM POWER (2 Amp to 5 Amp) Number shows the quantity of modules within a range LOW DENSITY (<50 Relays) N 20 EW 13 General Purpose Relay Modules General Purpose Relay Modules pickering pickeringtest.com Pickering LXI Modular Chassis & Associated Modules RF Microwave Multiplexers RF && Microwave Multiplexers LXI from Pickering Interfaces Pickering Interfaces were early adopters of the LXI standard as a means of providing a standardized interface for Ethernet (LAN) controlled instruments. pickering VIDEO MUX MICROWAVE MUX Further literature available on Pickering LXI Products l A wide range of switching functions are available including low frequency, high density matrices, RF and LXImate Book microwave matrices and multiplexers, and optical switching. Pickering has released the third edition of the LXImate book. The 122 page LXImate is an overview of the LXI Standard - an open, accessible standard identifying specifications and solutions relating to the functional test, measurement and data acquisition industry. This new edition has been updated to reflect the change in how products are offered, moving away from a class structure to a structure describing a Core Specification and a set of optional Extended Functions. To request a copy of LXImate, go to pickeringtest.com/lximate. l Custom switching solutions available - existing products can be adapted to meet a specific requirement or a completely custom solution can be created. l Compatible with all popular software: Windows® 8/7/Vista/XP, Visual Studio® (VB.NET, C#, C/C++), LabVIEW™, LabVIEW RT™, LabWindows/CVI™, VISA (NI and Agilent), IVI, NISE, Agilent VEE, Mathworks Matlab, Marvin Test ATEasy, MTQ Testsolutions Tecap. l Pickering switch modules set the benchmarks by which others are judged, constantly providing the densest and highest performance solutions available. l Pickering Interfaces is a Strategic Member of the LXI Consortium. Pickering is the only provider of LXI and PXI switching products with in-house reed relay manufacturing capability - instrument grade reed relays ensure long service life and repeatable contact performance (for further information visit pickeringrelay.com). In addition, most of Pickering's switch modules use through hole technology relays (as opposed to surface mount) allowing easy replacement without the need for special tools. l High Performance Multiplexer Suitable For Video Switching Applications l Automatic Termination of Unused Inputs Features Details the full range of LXI switching systems and modular products - 158 pages. 60-721A 60-722 Configurations 24, 48, 72, 96, 120 or 144 Channel MUX With Terminations Single or Dual 12 Channel MUX 60-800 6 Channel MUX With 4, 8, 12 or 16 Banks 60-820 6 Channel Terminated MUX With 2, 4, 6 or 7 Banks 6 Channel MUX With 4, 8, 12 or 16 Banks 75Ω 75Ω 1GHz 1GHz 18GHz 26.5GHz 2.5GHz Insertion Loss 3.5dB 1.3dB 0.5dB 0.7dB 0.3dB VSWR 1.7:1 1.5:1 1.5:1 1.5:1 1.3:1 0.5W (limited by termination resistors) 400W 5ms 20ms Typical Operate Time Relay Type All books and catalogs can be ordered from a Pickering Sales Office or downloaded from pickeringtest.com/catalog/ l High Performance 6-Channel Multiplexer l Up to 16 Multiplexer Banks l Low Loss High Isolation Frequency Range Max Power Select high density matrix solutions are supplied with Built-In Relay Self-Test. This allows the easy detection of faulty or deteriorating relay contacts to help in the diagnosis and verification of complex switching systems. l High Performance 6-Channel Multiplexer l Up to 16 Multiplexer Banks l Terminated Versions Available Model Family Impedance The LXI Product Catalog l High Performance 12-Channel Multiplexer l 1GHz Bandwidth l Single or Dual Multiplexer Banks 4 12 2 6 50Ω 75Ω 240W 1W Terminated 400W 18ms Electro-mechanical Microwave Relay Connector Type F-Type F-Type Microwave Relay Enclosure Size 2U or 3U High, Full Rack Width, 500mm Deep 2U High, Full Rack Width, 500mm Deep SMA HIGH DENSITY Ethernet Controlled Switching Solutions for Test, Measurement and Data Aquisition ● 600+ Modular Solutions ● 150+ Switch Systems LAN eXtensions for Instrumentation DIN 1.6/5.6 2U High, Full Rack Width, 500mm Deep Low Low Frequency Matrices Frequency Matrices HIGH DENSITY - DUAL ANALOG BUS Pickering Interfaces LXI Solutions Map 21 RF MUX - HIGH ISOLATION Number shows the quantity of modules within a particular range pickeringtest.com Pickering LXI Ethernet Switch Systems 71 HIGH POWER HIGH VOLTAGE LOW THERMAL EMF ethernet 14 l Single Pole High Density Matrix l Up to 4096 Crosspoints l Dual Analog Bus Features 12 13 l Single Pole High Density Matrix l Up to 4096 Crosspoints l X and Y Axis Loop-Thru l Easily Expanded to Larger Sizes l Double Pole High Density Matrix l Up to 4096 Crosspoints l Dual Analog Bus 7 l Single Pole High Density Matrix l Up to 4096 Crosspoints l Y Axis Loop-Thru l Easily Expanded to Larger Sizes 2 l Single Pole High Density Matrix l Up to 1600 Crosspoints l X and Y Axis Loop-Thru l Easily Expanded to Larger Sizes 8 l Single Pole Power Matrix l Up to 256 Crosspoints l 10A Current Rating l Double Pole High Voltage Matrix l Up to 600 Crosspoints l Up To 1000V Rating Model Family 60-550 60-551 60-555 60-556 60-552 60-554 60-590 60-600 Configurations Between 128x8 and 512x8 1-Pole Matrix Between 128x4 and 512x4 1-Pole Matrix Between 192x8 and 512x8 2-Pole Matrix Between 192x4 and 512x4 2-Pole Matrix Between 16x64 and 50x64 1-Pole Matrix Between 64x16 and 256x16 1-Pole Matrix 40x20 or 40x40 (can be used as Dual 40x20) Includes two "S" buses with isolation switching Single 16x16, 16x8, 16x4, 32x8, 32x4, 64x4 1-Pole or Dual 16x8, 32x4 1-Pole Matrix Relay Type Electro-mechanical Max Switch Voltage Max Switch Power Typical Operate Time Connector Type Mating Connectors and Cabling Datasheet 60-310 Single 100x2, 200x2 or 300x2 2-Pole Matrix l Single Pole Low Thermal EMF Matrix l Up to 1848 Crosspoints l Uses High Quality Electro-mechanical Relays 60-311 60-510 60-511 Single, Dual or Triple 75x4 2-Pole Matrix Single, 56x33, 44x33, 42x33, 28x33 or 14x33 1-Pole Matrix Single, 56x33, 44x33, 28x33 or 14x33 1-Pole Matrix Electro-mechanical High Voltage Rhodium Reed Electro-mechanical Pickering Instrumentation Ruthenium Reed Electro-mechanical 300VDC/250VAC 400VDC/250VAC Cold Switch, 125VDC/250VAC Hot Switch 750VDC Working, 1000VDC Typical, Cold Switch, 500VDC Hot Switch 750VDC Continuous, 1000VDC Pulse Cold Switch, 220VDC/250VAC Hot Switch 150VDC/100VAC 200VDC/170VAC 2A 10A 1A 2A Cold Switch, 1A Hot Switch 0.5A Switch, 0.5A Carry 1A 60W 300W/2500VA 10W 30W Hot Switch 10W 60W 3ms 10.5ms 0.5ms 3ms Crosspoint, 6ms Crosspoint + Isolation 0.5ms 3ms 50-Way D-type & 25-Way D-type 8-Way Power D-type 3ms Crosspoint, 6ms Crosspoint + Isolation 160-Way DIN 41612 78-Way D-type 78-Way D-type & 25-Way D-type 1U High, Full Rack Width, 500mm Deep 90-006D 1U High, Full Rack Width, 500mm Deep 90-001D 90-006D 50-Way High Voltage D-type & 9-Way High Voltage D-type 1U High, Full Rack Width, 500mm Deep 90-006D & 90-008D 91-100-001 90-005D & 90-008D 2U High, Full Rack Width, 500mm Deep 90-012D 91-100-001 HIGH FREQUENCY MATRIX 91-100-053 ─ RF Matrix - 2.4GHz 2013 90-007D & 90-008D ─ ─ Optical Switching 54 RF Matrix - 1GHz pickeringtest.com 2U High, Full Rack Width, 500mm Deep 90-005D & 90-003D 91-100-071 Pickering’s LXI Solutions Map is a single sheet reference to our range of LXI Switch Systems and LXI Modular Solutions and associated 600+ modules, including their basic specifications and cabling options. 37-Way D-type & 25-Way D-type 3U High, Full Rack Width, 500mm Deep RF &RFMicrowave Matrices & Microwave Matrices VIDEO MATRIX l Single Pole Low Thermal EMF Matrix l Up to 1848 Crosspoints l Uses Instrumentation Grade Reed Relays 4 2A 78-Way D-type Spare Relay Kits l Double Pole High Voltage Matrix l Up to 900 Crosspoints l Up To 750V Rating 5 60W 3ms Crosspoint, 6ms Crosspoint + Isolation Enclosure Size 3 Electro-mechanical 300VDC/250VAC Max Switch/Carry Current 3 36 Optical Switching MICROWAVE MATRIX pickering InterfacesInterfaces pickeringPickering Pickering FIBER OPTIC MULTIPLEXERS LXI ModuleLXI Map -Solutions Modular and System Map Switching 7 l Single or Dual 24x8 Matrix l Suitable For Video Switching Applications l Choice of RF Connectors Features Model Family Configurations Impedance Frequency Range Insertion Loss pickering 60-711 4 60-760 3 l High Bandwidth 75Ω Matrix l Useable to 1.5GHz l Automatic Termination of Unused Inputs 4 l High Bandwidth 75Ω Matrix l Useable to 1.5GHz l Automatic Termination of Unused Inputs 60-730 4 l High Bandwidth 75Ω Matrix l Useable to 1.5GHz l Automatic Termination of Unused Inputs 60-731 32x16 terminated, 24x16 terminated 16x16 terminated 60-732 32x8 terminated, 24x8 terminated 16x8 terminated, 8x8 terminated 3 l High Bandwidth 50Ω Matrix l Y Axis Loop-Thru l Automatic Termination of Unused Inputs 4 l High Bandwidth 50Ω Matrix l Y Axis Loop-Thru l Automatic Termination of Unused Inputs 60-770 32x4 terminated, 24x4 terminated 16x4 terminated, 8x4 terminated 60-771 32x16 terminated, 24x16 terminated 16x16 terminated 21 4 l High Bandwidth 50Ω Matrix l Y Axis Loop-Thru l Automatic Termination of Unused Inputs 32x8 terminated, 24x8 terminated 16x8 terminated, 8x8 terminated l Versatile Microwave Matrix Switching Solution l Loop-thru Option for Easy Expansion l Internal Termination Option 60-772 60-750 60-751 32x4 terminated, 24x4 terminated 16x4 terminated, 8x4 terminated Single or Dual 3x3, Single or Dual 4x4, Single 8x4, Optional Loop-thru and/or Terminations Single 3x3, Single 4x4, Optional Loop-thru and/or Terminations Single or Dual 24x8 (software configurable) Single or Dual 24x8 (software configurable) 75Ω 50Ω 75Ω 50Ω DC to 25MHz DC to 50MHz (useable to 100MHz) DC to 1GHz (useable to 1.5GHz) DC to 2.4GHz DC to 10GHz DC to 20GHz <0.53dB <1dB <2.5dB <2.5dB <3.6dB <4.5dB 50Ω <1.8:1 <1.8:1 <1.8:1 <1.6:1 <1.6:1 Max Power 10W 10W 0.125W (limited by termination resistors) 0.5W (limited by termination resistors) 100W (1W for termination resistors) Typical Operate Time 3ms 3ms 3ms 3ms 18ms Relay Type Electro-mechanical Electro-mechanical Electro-mechanical Electro-mechanical Microwave Relay Connector Type SMB, MCX or BNC SMB or BNC F-type SMA SMA Enclosure Size 1U High, Full Rack Width, 340mm Deep or 2U High, Full Rack Width, 500mm Deep 1U High, Full Rack Width, 340mm Deep or 2U High, Full Rack Width, 500mm Deep Pickering LXI System 65 Modular Chassis 6U High, Full Rack Width,500mm Deep 3U High, Full Rack Width, 500mm Deep W Wide Band Modular Matrix E N Pickering Interfaces VSWR l Single or Dual 24x8 Matrix l 50MHz Bandwidth, Useable to 100MHz l SMB or BNC RF Connectors Pickering's LXI System 65 Modular Chassis offers the user a solution that can be easily re-configured by the removal and insertion of subcards. The unit is purchased as an empty chassis with a baseboard and the quantity of System 65 sub-cards initially required. As the user's requirements evolve, additional cards can be easily fitted and the control software automatically detects the new configuration. 2U or 3U High, Full Rack Width, 500mm Deep 6U High, Full Rack Width, 500mm Deep 3U High, Full Rack Width, 500mm Deep 2U or 3U High, Full Rack Width, 500mm Deep l Single-Mode Fiber Support l MEMS Based Actuation For Long Life and Fast Operation l Loop-Thru Option For Easy Expansion Features Model Family 60-850 60-851 Configurations Single 8-Channel, Dual 4-Channel, Dual 8-Channel, Single 16-Channel or Single 32-Channel Single 8-Channel, Dual 4-Channel, Dual 8-Channel, Single 16-Channel or Single 32-Channel Switching Technology MEMS (Micro Electro-Mechanical Systems) Wavelength 1240nm to 1640nm Internal Fiber Type MM 62.5/125 1ms Cycle Rate Connector Type LAN eXtensions for Instrumentation 700nm to 1700nm SM 9/125 Typical Operate Time 2U High, Full Rack Width, 500mm Deep l Multi-Mode Fiber Support l MEMS Based Actuation For Long Life and Fast Operation l Loop-Thru Option For Easy Expansion 500/sec FC/APC, FC/PC, SC/PC, MU, LC Enclosure Size SC, ST ethernet 1U High, Full Rack Width, 340mm Deep Comprehensive Range of Cables &Solutions Connectors Comprehensive Range of Connector and Cabling Power Management Power Management AC POWER MANAGEMENT SWITCH 23 36 MULTI-WAY CABLES & CONNECTORS RF CABLES More Information on Cables & Connectors Features Range of Connectors 23 Features l User Configurable For X and Y Dimensions l Plug In As Many Cards As Required l Built In Self-Test Checks all Relays Features l Provides a Controlled Startup of Test Systems l Supports Up To 8 Instruments l Settable Timing Interval and Sequence l Permits Remote Re-Booting of Systems Model Family 65-110 Model Family 60-200 Configurations Between 24x8 and 104x8 or Between 16x16 and 104x16 Configurations One Power Input, Eight Separately Controlled Power Outputs Impedance Frequency Range 50Ω 200MHz Useable to 500MHz Switch Type Insertion Loss Dependent upon matrix size and signal path Current Rating VSWR Dependent upon matrix size and signal path On/Off Initiation Max Power Typical Operate Time Relay Type 0.25W (limited by termination resistors) 5ms Electro-mechanical Connector Type SMB Enclosure Size 4U High, Full Rack Width, 500mm Deep Timing Emergency Shutdown Electro-mechanical DPST 6A Max Per Channel, 10A Max Total Remotely or Via Front Panel Switch Output delay of 0 to 60s For Each Channel Push Button or Remotely via Front Panel Connector Connector Type IEC Mains Connector Enclosure Size 1U High, Full Rack Width, 340mm Deep Range of Connector Blocks Available Connector Types: l 200 Way LFH l 160 Way DIN 41612 l 96 & 68 Way SCSI Style Micro-D l 50 Way IDC l 78, 50, 37, 26, 25, 15 & 9 Way D-Type l 50, 37 & 9 Way High Voltage D-type l 20 Way GMCT (MS-M) l 26 Way GMCT (MS-M) RF Coaxial l 3, 4 & 8 Way Power D-Type l 200 Way LFH l 160 Way DIN 41612 l 96 & 68 Way SCSI Style Micro-D l 50 Way IDC l 78, 50, 37, 25 & 9 Way D-Type Connector Formats: Connector Block Formats: l Male or Female l Straight or Right Angled l PCB or Cable Mount l Solder or Crimp l With or Without Backshell l Shielded l Module Mounted l BRIC Mounted l DIN Rail Mounted l Screw Terminals Refer to the Cables & Connectors Catalog or individual connector data sheets to see which connector formats are available for each connector type. Refer to the Cables & Connectors Catalog or individual connector data sheets to see which connector block formats are available for each connector type. Available Connector Types: Range of Cables Range of 50Ω & 75Ω Coaxial Cables Available Connector Types: Available RF Cables: l 200 Way LFH l 160 Way DIN 41612 l 96 & 68 Way SCSI Style Micro-D l 78, 50, 37, 26, 25, 15 & 9 Way D-Type l 50, 37 & 9 Way High Voltage D-type l 20 Way GMCT (MS-M) l 26 Way GMCT (MS-M) RF Coaxial l 3, 4 & 8 Way Power D-Type l BNC to BNC 50Ω l SMB to SMB 50Ω l SMA to SMA 50Ω l µWave SMA to µWave SMA 50Ω l MCX to MCX 50Ω l SMB to BNC 50Ω l SMB to SMA 50Ω l F type to SMA 50Ω l BNC to BNC 75Ω l SMZ/type43 to SMZ/type43 75Ω l 1.0/2.3 to 1.0/2.3 75Ω l Mini SMB to Mini SMB 75Ω l MCX to MCX 75Ω l F type to F type 75Ω l 1.6/5.6 to 1.6/5.6 75Ω l Mini SMB to BNC 75Ω l Mini SMB to SMZ/type43 75Ω l Mini SMB to 1.0/2.3 75Ω Cable Formats: l Male to Male l Male to Female l Female to Female l Male to Unterminated l Female to Unterminated l Lengths of 0.5m, 1m, 2m or Custom Refer to the Cables & Connectors Catalog or individual connector data sheets to see which cable formats are available for each connector type. All cables are available in 0.1m, 0.25m, 0.5m, 1m or custom lengths. Cables & Connectors Map Outlines the range of cable and connector options available for LXI and PXI switching modules. ● Extensive Range of Switching: Matrix, MUX and General Purpose. ● RF/Microwave Switching to 65GHz. ● Comprehensive Range of Cables and Connectors. ● High Current to 40A, High Voltage to 1kV. ● Standard Three Year Warranty on all Modules and Switching Systems. ● Gigabit Ethernet. Direct Sales & Support Offices Cables & Connectors Catalog Details the available cable and connector options Pickering can supply for any module in the LXI and PXI ranges - 170 pages. All books and catalogs can be ordered from a Pickering Sales Office or downloaded from pickeringtest.com/catalog/ Pickering Interfaces Inc. Grants Pass,OR 97526 USA Tel: +1 541-471-0700 e-mail: [email protected] Pickering Interfaces Sarl Noisiel, Marne-la-Vallée France Tel: +33 1 60 53 55 50 e-mail: [email protected] Pickering Interfaces Ltd. Clacton-on-Sea UK Tel: +44 (0)1255-687900 e-mail: [email protected] Pickering Interfaces AB Varberg Sweden Tel: +46 340-69 06 69 e-mail: [email protected] Pickering Interfaces Inc (East Coast Regional Office) Burlington, Massachusetts USA Tel: +1 781-229-5882 e-mail: [email protected] Pickering Interfaces GmbH Haar-Salmdorf Germany Tel: +49 89 125 953 160 e-mail: [email protected] Pickering Interfaces s.r.o. ˇ Trinec Czech Republic Tel: +420 558 987 613 e-mail: [email protected] MTCS Systems Engineering Co. Ltd Beijing 100089 China Tel: 86-10-5881-6565 Website URL: www.mtcs.com.cn Local Sales Offices in Australia, Belgium, Brazil, Canada, India, Indonesia, Israel, Italy, Japan, Malaysia, Netherlands, New Zealand, Philippines, Russia, Singapore, South Korea, Spain, Taiwan, Thailand and Vietnam pickeringtest.com © 2013 © Copyright (August 2013) Pickering Interfaces Ltd. All Rights Reserved. All product and company names listed are trademarks or trade names of their respective companies.