Transcript
Q48SC12042 500W DC/DC Power Modules
FEATURES
Input voltage range: 36V~75V
Output voltage range ( trim and PMBUS) 8V~13.2V
Fully regulated from 36 to 75Vin
High efficiency : 95.0% @ 48Vin/42A
Size: 58.4mm x 36.8mm x 12.7mm (2.3” x 1.45” x 0.50”)
Industry standard DOSA compliant pin out
Fully protected: Input UVLO, Output OCP and OVP, OTP
Delphi Series Q48SC12042, Quarter Brick Family DC/DC Power Modules: 36~75Vin, 12Vout, 500W
Droop current sharing
1500V isolation
No minimum load required
Fixed frequency operation
ISO 9001, TL 9000, ISO 14001, QS9000,
OHSAS18001 certified manufacturing facility UL/CUL 60950-1 (US & Canada)
OPTIONS
Positive or Negative On/Off logic
The Delphi series Q48SC12042, quarter brick, 36~75V input,
Droop current sharing
single output 12V, are full digital control DC/DC converter, and
Digital pins
are the latest offering from a world leader in power system and technology and manufacturing ― Delta Electronics, Inc. This product provides up to 500 watts of power at 36~75V input in an industry standard, DOSA compliant footprint and pin out. The Q48SC12042 offers more than 95.0% high efficiency at 48V input, 12V output and 42A load. There is a built-in digital PWM controller in the Q48SC12042 series, which is used to complete the Vo feedback, PWM signal generation, droop or active
APPLICATIONS
current sharing, fault protection, output voltage trim, on/off
Datacom / Networking
control and PMBUS communications, and so on. With the digital
Wireless networks
control, many design and application flexibility, advanced
Optical network equipment
performance, and reliability are obtained. The Q48SC12042 can
Server and data storage
be connected in parallel directly for higher power without adding external oring-fet.
Industrial / Test equipment
Datasheet DS_Q48SC12042_04262016
E-mail:
[email protected] http://www.deltaww.com/dcdc
P1
TECHNICAL SPECIFICATIONS (TA=25°C, airflow rate=400 LFM, Vin=48Vdc, nominal Vout unless otherwise noted.)
PARAMETER
NOTES and CONDITIONS
Q48SC12042 Min.
ABSOLUTE MAXIMUM RATINGS Input Voltage Continuous Transient (100ms) On/off Pin Voltage Other Pin Voltage Output negative voltage Operating ambient Temperature Storage Temperature Input/Output Isolation Voltage INPUT CHARACTERISTICS Operating Input Voltage Input Under-Voltage Lockout Turn-On Voltage Threshold (Adjustable via PMBus, VIN_ON) Turn-Off Voltage Threshold (Adjustable via PMBus, VIN_OFF) Lockout Hysteresis Voltage Maximum Input Current No-Load Input Current Off Converter Input Current Input Capacitance Inrush Current (I2t) Input Reflected-Ripple Current Input Voltage Ripple Rejection OUTPUT CHARACTERISTICS The module without droop current sharing option code Output Voltage Set Point (Adjustable via PMBus) Output Voltage Regulation Over Line Over Load Over tempearture The module with droop current sharing option code Output Voltage Set Point (Adjustable via PMBus) Output Voltage Regulation Over Line Over Load Over tempearture Both with and without droop current sharing option code Output Voltage Trim and PMBUS Range Output Voltage Remote Sense Range (note 2) Output Over-Voltage Lockout (Adjustable via PMBus, VOUT_OV_FAULT_LIMIT) Operating Output Current Range Output DC Current-Limit Inception Output Capacitance Output Voltage Ripple and Noise Peak-to-Peak RMS
Typ.
0 100ms Trim/Current Sharing, C2, Data, SMBAlert, Clock, Addr1, Addr0
-50 -0.3 -40 -55
36
48
34 31
Max.
Units
75 100 50 3.6 0.3 85 125 1500
Vdc Vdc V V V °C °C Vdc
75
Vdc
36
Vdc
34
Vdc
2 Vin=36V, 100% Load Vin=48V Vin=48V
80 10 100
110 18
17.5 140 26 1
P-P thru 12µH inductor, 5Hz to 20MHz 120Hz
Vin=48V, Io=0A , Ta=25°C
60 50
11.88
12
Vin=36V to 75V, Io=100% load Vin=36V to 75V, Io=Io,min to Io,max Vin=36V to 75V, Io=100% load, Ta= -40C to 85C Vin=48V, Io=0A , Ta=25°C
12.28
12.4
Vin=36V to 75V, Io=100% load Vin=36V to 75V, Io=Io,min to Io,max Vin=36V to 75V, Io=100% load, Ta= -40C to 85C
-750
-500
Vin=36V to 75V, Pout ≦ max rated power,Io ≦ Io.max Vin=36V to 75V, Pout ≦ max rated power,Io ≦ Io.max
-33.3 5.8
12.12
Vdc
±40 ±40
mV mV mV
12.52
Vdc
±40
mV mV mV
10 10
% %
15.2 Full input voltage range
0 115 300
Vin=48V, Full load, 20MHz bandwidth Co= 300uF/16V (polymer ) + 10u/16V (Tantalum Capacitor) +1u/16V (Ceramic ) Co= 300uF/16V (polymer ) + 10u/16V (Tantalum Capacitor) +1u/16V (Ceramic )
Vdc A mA mA uF A2S mA dB
Vdc 42 135 15000
A % µF
75
110
mV
22
32
mV
350 -350 500
500
mV mV µs
DYNAMIC CHARACTERISTICS Output Voltage Current Transient Positive Step Change in Output Current Negative Step Change in Output Current Settling Time (within 1% Vout nominal) Turn-On Transient (Adjustable via PMBus) Start-Up Time, From On/Off Control Start-Up Time, From Input Output voltage Rise Time EFFICIENCY 100% Load 60% Load ISOLATION CHARACTERISTICS Input to Output Isolation Resistance Isolation Capacitance
DS_Q48SC12042_04262016
Vin=48V, Load Slew rate 0.1A/µs with a 1uF ceramic , a 10uF tantalum, and a 300uF polymer capacitor 50% Io.max to 75% Io.max 75% Io.max to 50% Io.max
-500
From On/off to 90%Vo final value From Input to 90%Vo final value From 10%Vo final value to 90%Vo final value
55 75 30
ms ms ms
Vin=48V Vin=48V
95.0 96.0
% % 1500
10 6800
Vdc MΩ pF
E-mail:
[email protected] http://www.deltaww.com/dcdc
P2
TECHNICAL SPECIFICATIONS (TA=25°C, airflow rate=400 LFM, Vin=48Vdc, nominal Vout unless otherwise noted.)
PARAMETER
NOTES and CONDITIONS
Q48SC12042 Min.
FEATURE CHARACTERISTICS Switching Frequency ON/OFF Control, Positive Remote On/Off logic Logic Low (Module On) Logic High (Module Off) ON/OFF Current (for both remote on/off logic) GENERAL SPECIFICATIONS MTBF Weight Over-Temperature Shutdown
Typ.
Max.
130 Von/off at Ion/off=1.0mA Von/off at Ion/off=0.0 µA Ion/off at Von/off=0.0V
-0.7 3.5
Io=80% of Io max; Ta=25°C; Airflow=300LFM Refer to Figure 21 for Hot spot location (48Vin,80% Io, 200LFM,Airflow from Vin+ to Vin-)
(With heat spreader)
Units KHz
0.8 50 0.5
V V mA
2.2 65
M grams
115
°C
Over-Temperature Shutdown ( NTC resistor ) 125 °C Note1: Please attach thermocouple on NTC resistor to test OTP function, the hot spots’ temperature is just for reference. And the OTP is Adjustable via PMBus. Note2: Output voltage range 5.8% for remote sense-; Output voltage range 10% for remote sense+.
DIGITAL INTERFACE SPECIFICATIONS (TA=25°C, airflow rate=400 LFM, Vin=48Vdc, nominal Vout unless otherwise noted.)
PARAMETER
NOTES and CONDITIONS
Q48SC12042 Min.
PMBUS SIGNAL INTERFACE CHARACTERISTICS Input High Voltage (CLK, DATA) Input Low Voltage (CLK, DATA) Input high level current (CLK, DATA) Input low level current (CLK, DATA) Output Low Voltage (SMBALERT#) Output high level open drain leakage current (SMBALERT#) PMBus Operating frequency range
Typ.
2.1 0 -10 -10 IOUT=2mA VOUT=3.6V
0
Max.
Units
3.3 0.8 10 10 0.4
Vdc Vdc uA uA Vdc
10 100 or 400
uA kHz
Measurement System Characteristics 10.5A
10.2
Volts
-12
/
Write command FREQUENCY_SWITCH
0x33
Frequency Yes
120 ~ 130
linear
KHz
-2
need module off
180 condition
DS_Q48SC12042_04262016
E-mail: [email protected] http://www.deltaww.com/dcdc
P16
Compatible Transf
with
-er
standard
Command Command
Data Command description
Code
Note Format
type
Default Range Data Expon value
limit
units
-ent
35
33~36
V
-3
PMBUS or not?
Set the turn on voltage R/W VIN_ON
0x35
threshold of Vin under
Vin Yes
word
VIN_ON should be higher than
Linear
VIN_OFF
voltage lockout Set the turn off voltage R/W VIN_OFF
0x36
threshold of Vin under
Vin Yes
VIN_ON should be higher than 33
word
Linear
R/W
Vout
31~34
V
-3 VIN_OFF
voltage lockout Set the output VOUT_OV_FAULT_L 0x40
Must be higher than the value
overvoltage fault
IMIT
Yes word
15
11~16
V
-12
of VOUT_COMMAND
and
Linear
threshold.
VOUT_OV_WARN_LIMIT;
Instructs what action to VOUT_OV_FAULT_
Read Refer to below 0x41
take in response to an
RESPONSE
Bit field byte
0xB8
/
N/A
/
Default Hiccup mode
description;
output overvoltage fault. Set a threshold causing VOUT_OV_WARN_L
Must be the same or less than R/W
0x42
an output voltage high
IMIT
Vout Yes
word
14
11~16
V
-12
VOUT_OV_FAULT_LIMIT
Linear
warning.
value Must be greater than
IOUT_OC_FAULT_LI
Set the output overcurrent
R/W
fault threshold.
word
0x46 MIT
Iout Yes
53
33~55
A
-4
IOUT_OC_WARN_LIMIT
Linear value
Instructs what action to IOUT_OC_FAULT_R
Read Refer to below 0x47
take in response to an
ESPONSE
Bit field byte
0xF8
/
N/A
/
Default Hiccup mode
description;
output overcurrent fault. Set a threshold causing IOUT_OC_WARN_LI
Must be less than R/W
0x4A
an output current high
MIT
Iout Yes
word
47
33~55
A
-4
warning. Set the over temperature OT_FAULT_LIMIT
value R/W
0x4F
TEMP Yes
fault threshold.
IOUT_OC_FAULT_LIMIT
Linear
word
25~14 Deg. 125
Linear
Must be greater than -2
0
C
/
N/A
OT_WARN_LIMIT value
Instructs what action to OT_FAULT_RESPO
Read Refer to below 0x50
take in response to an
NSE
Bit field byte
0xB8
/
Default Hiccup mode
description;
over temperature fault.
DS_Q48SC12042_04262016
E-mail: [email protected] http://www.deltaww.com/dcdc
P17
Compatible with Comman Command
Transf Command description
d Code
Data
Default
Range
Data
Expon
Format
value
limit
units
-ent
standard -er type
Note
PMBUS or not? Must be less OT_WARN_
Set a threshold causing a 0x51
LIMIT
TEMP R/W word
Yes
temperature high warning.
than 100
25~140
Deg.C
-2
Linear
OT_FAULT_LI MIT value
VIN_OV_FA
Set the input overvoltage fault 0x55
Vin R/W word
ULT_LIMIT
threshold.
VIN_OV_FA
Instructs what action to take in
Yes
100
48~100
V
-3
0XF8
/
N/A
/
Refer to below ULT_RESPO
0x56
response to an input
/
Linear
Read byte
Default Hiccup Bit field
description; NSE
mode
overvoltage fault. Must be greater Sets the output voltage at which
POWER_GO
Vout 0x5E
the bit 3 of STATUS_WORD
R/W word
Yes
OD_ON
8 11
Linear
than V
-12
~13.2
POWER_GOO
high byte should be asserted. D_OFF value Must be less Sets the output voltage at which POWER_GO
Vout 0x5F
the bit 3 of STATUS_WORD
R/W word
Yes
OD_OFF
8 9
Linear
than V
-12
~13.2
POWER_GOO
high byte should be negated. D_ON value Sets the time from a start Time TON_DELAY
0x60
condition is received until the
R/W word
Yes
20
20~500
ms
-1
/
30
15~500
ms
-1
/
Bit field
/
/
/
/
/
Bit field
/
/
/
/
/
Bit field
/
/
/
/
/
Linear output voltage starts to rise Sets the time from the output Time TON_RISE
0x61
starts to rise until the voltage
R/W word
Yes Linear
has entered the regulation band. Returns the information with a STATUS_W 0x79
Read
Refer to below
word
description;
summary of the module's
ORD fault/warning Returns the information of the STATUS_VO
Refer to below 0x7A
module's output voltage related Read byte
UT
description; fault/warning Returns the information of the
STATUS_IO
Refer to below 0x7B
module's output current related
UT
Read byte description;
fault/warning
DS_Q48SC12042_04262016
E-mail: [email protected] http://www.deltaww.com/dcdc
P18
Compatible with Comman Command
Transf Command description
d Code
Data
Default
Range
Data
Expon
Format
value
limit
units
-ent
Bit field
/
/
/
/
/
Bit field
/
/
/
/
/
Bit field
/
/
/
/
/
/
/
V
-3
/
/
/
V
-12
/
/
/
A
-4
/
/
/
Deg.C
-2
/
Bit field
0x42
/
/
/
/
Bit field
0x00
/
/
/
/
Bit field
0x00
/
/
/
/
Bit field
0x01
/
/
/
standard -er type
Note
PMBUS or not? Returns the information of the STATUS_IN
Refer to below 0x7C
module's input over voltage and Read byte
PUT
description; under voltage fault
STATUS_TE
Returns the information of the Refer to below
MPERATUR
0x7D
module's temperature related
Read byte description;
E
fault/warning Returns the information of the
STATUS_CM
Refer to below 0x7E
module's communication related Read byte
L
description; faults. Returns the input voltage of the
READ_VIN
Read
0x88
READ_VOU
module
word
Returns the output voltage of
Read
0x8B T
READ_IOUT
Vin Yes Linear Vout Yes
the module
word
Returns the output current of the
Read
0x8C
Linear Iout Yes
module
word
Returns the module's hot spot
Read
Linear
READ_TEM PERATURE_
0x8D
TEMP Yes
temperature of the module
word
Linear
1 PMBUS_RE
Reads the revision of the 0x98
VISION
Read byte
Yes
PMBus
MFR_C1_C2 Refer to below _ARA_CONF
0xE0
Config C2 pin function
R/W byte description;
IG MFR_ C2_
Refer to below 0xE1
Config C2 pin logic
R/W byte
Configure
description;
MFR_PGOO 0xE2 D
Refer to below Config Power Good logic
R/W byte
Default Positive
description;
PGOOD logic
_POLARITY Total 11 MFR_SERIA
Read 0x9E
Reads the SN of module
L
ASCII
‘xxxxxxxxx
/ block
of module use /
charact ers
DS_Q48SC12042_04262016
The SN number
xx’
/
/ 11 ASCII characters
E-mail: [email protected] http://www.deltaww.com/dcdc
P19
OPERATION [0x01] Bit number
7:
Purpose
Enable/Disable the module
6:
Reserved
5:4
Margins
3:0
Bit Value
Meaning
1
Output is enabled
0
Output is disabled
Default Settings, 0x80 1
0 00
No margin
00
01
Margin low(Act on Fault)
10
Margin high(Act on Fault)
Reserved
0000
VOUT_OV_FAULT_RESPONSE [0x41] Bit number 7:6
Purpose Response settings
Bit Value
Meaning
Default Settings, 0xB8
10
Unit shuts down and responds according to the
10
retry settings 5:3
Retry setting
111
Unit continuously restarts while fault is present
111
until commanded off
2:0
Delay time setting
000
Unit does not attempt to restart on fault
000
No delay supported
000
IOUT_OC_FAULT_RESPONSE [0x47] Bit number 7:6
Purpose Response settings
Bit Value 11
Default Settings, 0xF8
Meaning Unit shuts down and responds according to the
11,
retry settings 5:3
Retry settings
111
Unit continuously restarts while fault is present
111
until commanded off
2:0
Delay time setting
000
Unit does not attempt to restart on fault
000
No delay supported
000
OT_FAULT_RESPONSE [0x50] Bit number
Purpose
Bit Value
7:6
Response settings
10
5:3
Retry settings
111
Default
Meaning
Settings,0xB8
Unit shuts down and responds according to the
10,
retry settings Unit continuously restarts while fault is present
111
until commanded off
2:0
Delay time setting
DS_Q48SC12042_04262016
000
Unit does not attempt to restart on fault
000
No delay supported
000
E-mail: [email protected] http://www.deltaww.com/dcdc
P20
VIN_OV_FAULT_RESPONSE [0x56] Bit number 7:6
Purpose Response settings
Bit Value
Meaning
Default Settings,0xF8
11
Unit shuts down and responds according to the
11
retry settings 5:3
Retry setting
111
Unit continuously restarts while fault is present
111
until commanded off
2:0
Delay time setting
000
Unit does not attempt to restart on fault
000
No delay supported
000
STATUS_WORD [0x79] High byte Bit number 7
6
5
Purpose An output over voltage fault or warning
Meaning
1
Occurred
0
No Occurred
1
Occurred
0
No Occurred
An input voltage fault, including over voltage and
1
Occurred
undervoltage
0
No Occurred
1
is negated
0
ok
An output over current fault or warning
4
Reserved
3
Power_Good
2:0
Bit Value
Reserved
Low byte Bit number
Purpose
7
Reserved
6
OFF (The unit is not providing power to the output, regardless of the reason)
5
4
An output over voltage fault
An output over current fault
3
An input under voltage fault
2
A temperature fault or warning
1
0
CML (A communications, memory or logic fault)
Bit Value
Meaning
1
Occurred
0
No Occurred
1
Occurred
0
No Occurred
1
Occurred
0
No Occurred
1
Occurred
0
No Occurred
1
Occurred
0
No Occurred
1
Occurred;
0
No Occurred
Reserved
DS_Q48SC12042_04262016
E-mail: [email protected] http://www.deltaww.com/dcdc
P21
STATUS_VOUT [0x7A] Bit number 7
6
5:0
Purpose Output over voltage fault
Output over voltage warning
Bit Value
Meaning
1
Occurred;
0
No Occurred
1
Occurred;
0
No Occurred
Reserved
STATUS_IOUT [0x7B] Bit number
Purpose
7
Output over current fault
6
Reserved
5
Output over current warning
4:0
Bit Value
Meaning
1
Occurred;
0
No Occurred
1
Occurred;
0
No Occurred
Reserved
STATUS_INPUT [0x7C] Bit number 7
6: 5 4
3:0
Purpose Input over voltage fault
Bit Value
Meaning
1
Occurred;
0
No Occurred
1
Occurred;
0
No Occurred
Reserved Input under voltage fault
Reserved
STATUS_TEMPERATURE [0x7D] Bit number 7
6
5:0
Purpose Over temperature fault
Over temperature warning
Bit Value
Meaning
1
Occurred;
0
No Occurred
1
Occurred;
0
No Occurred
Reserved
STATUS_CML [0x7E] Bit number 7
6
5
4:0
Purpose Invalid/Unsupported Command Received
Invalid/Unsupported Data Received
Packet Error Check Failed
Bit Value
Meaning
1
Occurred;
0
No Occurred
1
Occurred;
0
No Occurred
1
Occurred;
0
No Occurred
Reserved
DS_Q48SC12042_04262016
E-mail: [email protected] http://www.deltaww.com/dcdc
P22
MFR_C1_C2_ARA_CONFIG [0xE0] Bit number 7:5 4
Purpose Reserved
Bit Value 000
ARA
0
Meaning Reserved ARA not functional, module remains at resistor programmed address when SMBLAERT is asserted
3:0
PIN Configuration
0000
C2 pin: POWER_GOOD
0010
C2 pin: ON/OFF (Secondary)
MFR_ C2_Configure [0xE1] Bit number 7:2 1
Purpose Reserved
Bit Value 000000
ON/OFF Configuration
0
Meaning Reserved Secondary side on/off pin state when mapped to C2 is ignored
1
AND – Primary and Secondary side on/off
0
Secondary Side ON/OFF Logic
0
Negative Logic (Low Enable: Input < 0.8V wrt Vout(-)
1
Positive Logic (High Enable: Input > 2.0V wrt Vout(-)
MFR_PGOOD_POLARITY [0xE2] Bit number 7:1 0
Purpose Reserved Power Good Logic
DS_Q48SC12042_04262016
Bit Value 0000000
Meaning Reserved
0
Negative PGOOD logic
1
Positive PGOOD logic
E-mail: [email protected] http://www.deltaww.com/dcdc
P23
MECHANICAL DRAWING( WITH HEAT-SPREADER) *For modules with through-hole pins and the optional heat spreader, they are intended for wave soldering assembly onto system boards, please do not subject such modules through reflow temperature profile.
Pin Specification: Pins 1-4, 6~8 Pins 5,9 Pins 10-16
1.00mm (0.040”) diameter (All pins are copper with matte Tin plating over Nickel under plating) 2. 1.50mm (0.059”) diameter (All pins are copper with matte Tin plating over Nickel under plating) 1. SQ 0.50mm(0.020’’) ( All pins are copper with gold flash plating)
DS_Q48SC12042_04262016
E-mail: [email protected] http://www.deltaww.com/dcdc
P24
RECOMMENDED LAYOUT
DS_Q48SC12042_04262016
E-mail: [email protected] http://www.deltaww.com/dcdc
P25
PART NUMBERING SYSTEM Q
48
S
C
120
42
N
R
Type of Input Number of Product Output Output ON/OFF Pin Length Product Voltage Outputs Series Voltage Current Logic /Type Q48 SC120 - 42 - 42A P R - 0.170” Quarter 36~75V 12V Single Series Positive N - 0.145” Brick number NK - 0.110” Negative
D
H
Pin assigment
Option Code
DDigital pins AAnalog pins IIBC pins TTrim pins
Trim Pin
Current sharing
Heat spreader
Case pin
H
Yes
No
Yes
No
I
No
Droop
Yes
No
J
No
No
Yes
No
R
Yes
No
Yes
Yes
S
No
Droop
Yes
Yes
T
No
No
Yes
Yes
Note for mechaninal pins option: 1. D- Digital pins*: with digital pins & sense pins 2. A- Analog pins*: with sense pins, without digital pins 3. I- IBC pins*: without digital pins & sense pins 4. T- Trim pins: with digital pins, without sense pins *There is no Power Good (PG) function, if customers need , please contact with Delta.
MODEL LIST MODEL NAME
INPUT
EFF @ 100%LOAD
OUTPUT
Q48SC12042NRDH
36V~75V
17.5A
12V
42A
95.0%
Q48SC12042NRAH
36V~75V
17.5A
12V
42A
95.0%
Q48SC12042NRDR
36V~75V
17.5A
12V
42A
95.0%
Q48SC12042NRIJ
36V~75V
17.5A
12V
42A
95.0%
Note: If use VOUT_COMMAND of PMBUS to trim Vout set point, then the function of trim pin(6 pin) will be disabled immediately. And if need enable the function of trim pin(6pin) to trim Vout set point again, should turn off and turn on the input voltage of module to restart module.
CONTACT: www.deltaww.com/dcdc
Email: [email protected]
USA: Telephone: East Coast: 978-656-3993 West Coast: 510-668-5100 Fax: (978) 656 3964
Europe: Phone: +31-20-655-0967 Fax: +31-20-655-0999
Asia & the rest of world: Telephone: +886 3 4526107 ext 6220~6224 Fax: +886 3 4513485
WARRANTY Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon request from Delta. Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice. DS_Q48SC12042_04262016
E-mail: [email protected] http://www.deltaww.com/dcdc
P26