Transcript
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT
Page 1 Of 11
LUMINAIRE PHOTOMETRIC TEST REPORT
NAME: QS-NC-CL24W-CW-4000K
TYPE:
WEIGHT:
SPEC.:
DIM.:
SERIAL No.:
MFR.: EVERFINE
SUR.:
PROTECTION ANGLE:
DATA OF LAMP
PHOTOMETRIC DATA
Eff: 68.61 lm/W
MODEL QS-NC-CL24W-CW-4000K
Imax(cd)
401.8
S/MH(C0/180)
1.30
NOMINAL POWER(W)
22
LOR(%)
100.0
S/MH(C90/270)
1.31
RATED VOLTAGE(V)
242
TOTAL FLUX(lm)
1458.9
h UP,DN(C0-180)
4.6,47.5
NOMINAL FLUX(lm)
1458.87
CIE CLASS
DIRECT
h UP,DN(C180-360)
3.8,44.1
LAMPS INSIDE
1
h up(%)
8.4
CIBSE SHR NOM
1.25
TEST VOLTAGE(V)
241.4
h down(%)
91.6
CIBSE SHR MAX
1.35
LUMINOUS INTENSITY DISTRIBUTION DIAGRAM
C0 PLANE ISOLUX DIAGRAM (UNIT:lx) MH(m) 14 18
-/+180 -150
150
22 -120
120
26 30
0
-90
90
90
34 38
180
42 -60
270 360 -30
60 UNIT:cd C0/180,120.3deg C90/270,120.2deg
30 450 0 AVERAGE BEAM ANGLE(50%):120.2 DEG
C Range: 0 - 360DEG C Interval: 45.0DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2014-08-28
E:\吸顶灯IES大全\QS-NC-CL24W\QS-NC-Cl24W-CW-4000K.GOS
46 0.0
16.5 2.40 2.00 1.60 1.20 0.8000
g Range: 0 - 180DEG g Interval: 1.0DEG
0.4000 0.3200 0.2000 0.1600 0.1200
33.0 S(m)
Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.281 Humidity:65.0% Test Distance:6.200m [K=1.0000] Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT
Page 2 Of 11
ZONAL FLUX DIAGRAM
ZONAL FLUX DIAGRAM: g
g
F zone
F total
C0
C45
C90
C135
C180
C225
C270
C315
%lum,lamp
10
397.5
397.1
394.1
389.5
392.7
388.4
387.7
388.9
0- 10
37.72
37.72
2.59,2.59
20
380.7
382.2
378.2
370.9
371.0
365.2
365.7
369.7
10- 20
108.4
146.1
10,10
30
351.4
354.7
349.8
340.2
337.4
329.9
331.8
338.4
20- 30
165.4
311.5
21.4,21.4
40
310.8
315.7
310.3
298.6
293.5
285.0
287.8
296.7
30- 40
201.5
513.0
35.2,35.2
50
261.9
267.8
262.2
249.9
243.2
234.7
237.8
247.9
40- 50
212.9
725.9
49.8,49.8
60
210.7
216.7
211.4
199.2
192.6
184.5
187.6
197.8
50- 60
201.7
927.5
63.6,63.6
70
161.4
167.0
162.3
150.9
144.5
137.7
140.2
150.1
60- 70
174.0
1102
75.5,75.5
80
116.9
121.3
117.6
107.5
102.1
96.36
98.58
107.2
70- 80
136.9
1239
84.9,84.9
90
77.84
81.87
78.54
70.48
65.62
60.56
62.90
69.67
80- 90
97.24
1336
91.6,91.6
100
46.18
49.60
46.87
41.30
37.59
33.83
35.58
40.49
90-100
60.52
1396
95.7,95.7
110
23.93
26.46
24.63
21.14
18.76
16.32
17.23
20.49
100-110
32.36
1429
97.9,97.9
120
10.68
12.24
11.42
9.640
8.552
7.217
7.635
9.228
110-120
14.65
1443
98.9,98.9
130
4.727
5.460
5.444
4.761
4.399
4.197
4.210
4.645
120-130
6.081
1449
99.3,99.3
140
3.602
3.584
3.592
3.673
4.339
4.316
4.326
4.288
130-140
3.189
1453
99.6,99.6
150
3.966
3.949
3.954
4.022
4.488
4.460
4.473
4.435
140-150
2.566
1455
99.7,99.7
160
4.314
4.304
4.296
4.354
4.646
4.620
4.638
4.597
150-160
2.008
1457
99.9,99.9
170
4.597
4.597
4.592
4.635
4.770
4.739
4.764
4.739
160-170
1.296
1458
100,100
180
4.770
4.775
4.767
4.802
4.790
4.762
4.782
4.780
170-180
0.4507
1459
100,100
DEG
LUMINOUS INTENSITY:cd
C Range: 0 - 360DEG C Interval: 45.0DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2014-08-28
E:\吸顶灯IES大全\QS-NC-CL24W\QS-NC-Cl24W-CW-4000K.GOS
g Range: 0 - 180DEG g Interval: 1.0DEG
UNIT:lm
Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.281 Humidity:65.0% Test Distance:6.200m [K=1.0000] Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT
Page 3 Of 11
CU AND LUMINAIRE BUDGETARY ESTIMATE DIAGRAM
NAME: QS-NC-CL24W-CW-4000K
TYPE:
WEIGHT:
SPEC.:
DIM.:
SERIAL No.:
MFR.: EVERFINE
SUR.:
PROTECTION ANGLE:
r cc
80%
rw
50%
30%
r fc
70% 10%
50%
20%
RCR
30%
50% 10%
50%
20%
RCR:Room Cavity Ratio
30%
30% 10%
50%
20%
30%
10% 10%
50%
20%
30%
0 10%
20%
0 0
Coefficients of Utilization(CU)
0.0
1.17
1.17
1.17
1.13
1.13
1.13
1.06
1.06
1.06
1.00
1.00
1.00
.94
.94
.94
.92
1.0
.99
.93
.89
.95
.91
.86
.89
.86
.82
.84
.81
.78
.79
.77
.74
.71
2.0
.85
.77
.70
.82
.75
.69
.77
.71
.66
.72
.67
.63
.68
.64
.61
.58
3.0
.74
.65
.58
.71
.63
.57
.67
.60
.54
.63
.57
.52
.60
.55
.50
.48
4.0
.65
.56
.48
.63
.54
.48
.59
.52
.46
.56
.50
.44
.53
.47
.43
.40
5.0
.58
.48
.41
.56
.47
.41
.53
.45
.39
.50
.43
.38
.47
.42
.37
.35
6.0
.52
.43
.36
.50
.42
.35
.48
.40
.34
.45
.38
.33
.43
.37
.32
.30
7.0
.47
.38
.31
.46
.37
.31
.43
.36
.30
.41
.34
.29
.39
.33
.29
.26
8.0
.43
.34
.28
.42
.33
.28
.40
.32
.27
.38
.31
.26
.36
.30
.26
.23
9.0
.39
.31
.25
.38
.30
.25
.36
.29
.24
.35
.28
.24
.33
.27
.23
.21
10.0
.36
.28
.23
.35
.28
.22
.34
.27
.22
.32
.26
.21
.31
.25
.21
.19
LAMPS 50
LUMINAIRE BUDGETARY DIAGRAM
40 30
20
H=8 7
10 9 8 7 6
CONDITIONS FLUX 2000lm FACTOR 0.70 Hdown 0.00m Hwork 0.80m Ework(AVE) 100lx cc w fc r (%) 70 50 30 50 30 20
6
5
5
4 H=5 3 4 2
10
2
3 20
30
40 50
70
100
C Range: 0 - 360DEG C Interval: 45.0DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2014-08-28
E:\吸顶灯IES大全\QS-NC-CL24W\QS-NC-Cl24W-CW-4000K.GOS
200 300 AREA(m2)
500 700
g Range: 0 - 180DEG g Interval: 1.0DEG
1k
2k
3k
4k 5k
7k
Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.281 Humidity:65.0% Test Distance:6.200m [K=1.0000] Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT
Page 4 Of 11
WEC AND CCEC
NAME: QS-NC-CL24W-CW-4000K
TYPE:
WEIGHT:
SPEC.:
DIM.:
SERIAL No.:
MFR.: EVERFINE
SUR.:
PROTECTION ANGLE:
r cc rw
80% 50%
r fc
RCR
30%
70% 10%
50%
20%
30%
50% 10%
50%
20%
30%
30% 10%
50%
20%
RCR:Room Cavity Ratio
30%
10% 10%
50%
20%
30%
0 10%
20%
0 0
Wall Exitance Coeffcients(WEC)
0.0 1.0
.374 .212 .067 .364 .208 .066 .345 .198 .063 .329 .189 .061 .313 .181 .058
2.0
.328 .180 .055 .319 .176 .054 .302 .168 .052 .287 .161 .050 .273 .155 .049
3.0
.293 .156 .047 .285 .153 .046 .270 .147 .045 .257 .141 .043 .244 .135 .042
4.0
.265 .138 .040 .258 .135 .040 .245 .130 .039 .232 .125 .038 .221 .120 .037
5.0
.242 .123 .036 .235 .121 .035 .223 .116 .034 .212 .112 .033 .202 .108 .032
6.0
.222 .111 .032 .216 .109 .031 .205 .105 .031 .195 .101 .030 .186 .098 .029
7.0
.205 .101 .029 .200 .100 .028 .190 .096 .028 .181 .093 .027 .172 .089 .026
8.0
.190 .093 .026 .186 .091 .026 .177 .088 .025 .168 .085 .025 .161 .082 .024
9.0
.178 .086 .024 .173 .084 .024 .165 .082 .023 .158 .079 .023 .150 .076 .022
10.0
.166 .080 .022 .162 .078 .022 .155 .076 .021 .148 .073 .021 .141 .071 .020
r cc rw r fc
RCR
80% 50%
30%
70% 10%
20%
50%
30%
50% 10%
20%
RCR:Room Cavity Ratio
50%
30% 20%
30% 10%
50%
30% 20%
10% 10%
50%
30%
0 10%
20%
0 0
Ceiling Cavity Exitance Coefficients(CCEC)
0.0
.255 .255 .255 .218 .218 .218 .149 .149 .149 .085 .085 .085 .027 .027 .027
1.0
.250 .220 .194 .214 .189 .167 .146 .130 .116 .084 .075 .067 .027 .024 .022
2.0
.242 .197 .159 .208 .170 .137 .142 .117 .096 .082 .068 .056 .026 .022 .018
3.0
.235 .180 .137 .201 .155 .118 .138 .108 .083 .080 .063 .049 .026 .020 .016
4.0
.227 .167 .122 .194 .145 .106 .134 .101 .075 .077 .059 .044 .025 .019 .015
5.0
.219 .157 .112 .188 .136 .097 .129 .095 .069 .075 .056 .041 .024 .018 .013
6.0
.211 .149 .104 .182 .129 .091 .125 .090 .064 .073 .053 .038 .023 .017 .013
7.0
.204 .142 .099 .176 .123 .086 .121 .086 .061 .071 .051 .036 .023 .017 .012
8.0
.197 .137 .095 .170 .118 .083 .118 .083 .059 .068 .049 .035 .022 .016 .012
9.0
.191 .132 .092 .165 .114 .080 .114 .080 .057 .066 .047 .034 .022 .016 .011
10.0
.185 .127 .089 .160 .111 .078 .111 .078 .055 .065 .046 .033 .021 .015 .011
C Range: 0 - 360DEG C Interval: 45.0DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2014-08-28
E:\吸顶灯IES大全\QS-NC-CL24W\QS-NC-Cl24W-CW-4000K.GOS
g Range: 0 - 180DEG g Interval: 1.0DEG
Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.281 Humidity:65.0% Test Distance:6.200m [K=1.0000] Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT
Page 5 Of 11
Uncorrected UGR Table
NAME: QS-NC-CL24W-CW-4000K
TYPE:
WEIGHT:
SPEC.:
DIM.:
SERIAL No.:
MFR.: EVERFINE
SUR.:
PROTECTION ANGLE:
ceiling/cavity
0.7
0.7
0.5
0.5
0.3
0.7
0.7
0.5
0.5
0.3
walls
0.5
0.3
0.5
0.3
0.3
0.5
0.3
0.5
0.3
0.3
working plane
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
Room dimensions x =
2H y =
4H
8H
12H
Viewed crosswise
Viewed endwise
2H
21.6
23.1
22.0
23.5
23.8
21.6
23.1
22.0
23.5
23.8
3H
23.7
25.1
24.1
25.5
25.9
23.7
25.1
24.1
25.5
25.9
4H
24.8
26.1
25.2
26.5
26.9
24.8
26.1
25.2
26.5
27.0
6H
25.9
27.2
26.4
27.6
28.1
26.0
27.2
26.4
27.6
28.1
8H
26.6
27.8
27.0
28.2
28.7
26.6
27.8
27.1
28.2
28.7
12H
27.3
28.4
27.8
28.9
29.4
27.3
28.5
27.8
28.9
29.4
2H
22.4
23.7
22.8
24.1
24.5
22.4
23.7
22.8
24.1
24.5
3H
24.7
25.8
25.2
26.3
26.8
24.7
25.8
25.2
26.3
26.8
4H
25.9
27.0
26.4
27.5
28.0
26.0
27.0
26.5
27.5
28.0
6H
27.3
28.2
27.8
28.7
29.3
27.3
28.3
27.8
28.8
29.3
8H
28.0
28.9
28.6
29.4
30.0
28.0
28.9
28.6
29.4
30.0
12H
28.8
29.7
29.4
30.2
30.8
28.9
29.7
29.4
30.2
30.8
4H
26.5
27.3
27.0
27.9
28.4
26.5
27.4
27.0
27.9
28.5
6H
28.1
28.8
28.7
29.4
30.0
28.1
28.9
28.7
29.4
30.0
8H
29.0
29.7
29.6
30.2
30.9
29.0
29.7
29.6
30.3
30.9
12H
30.0
30.6
30.7
31.2
31.9
30.1
30.7
30.7
31.3
31.9
4H
26.6
27.4
27.1
27.9
28.5
26.6
27.4
27.1
27.9
28.5
6H
28.3
29.0
28.9
29.6
30.2
28.3
29.0
28.9
29.6
30.2
8H
29.3
29.9
29.9
30.5
31.2
29.4
29.9
30.0
30.5
31.2
Variations with the observer position at spacings: S = 1.0H
+ 0.1 / - 0.1
+ 0.1 / - 0.1
1.5H
+ 0.2 / - 0.3
+ 0.2 / - 0.3
2.0H
+ 0.2 / - 0.4
+ 0.2 / - 0.4
CIE Pub.117 Corrected 1459 lm Total Lamp Luminous Flux.(8log(F/F0) = 1.3)
C Range: 0 - 360DEG C Interval: 45.0DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2014-08-28
E:\吸顶灯IES大全\QS-NC-CL24W\QS-NC-Cl24W-CW-4000K.GOS
g Range: 0 - 180DEG g Interval: 1.0DEG
Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.281 Humidity:65.0% Test Distance:6.200m [K=1.0000] Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT
Page 6 Of 11
UTILIZATION FACTORS TABLE
NAME: QS-NC-CL24W-CW-4000K
TYPE:
WEIGHT:
SPEC.:
DIM.:
SERIAL No.:
MFR.: EVERFINE
SUR.:
PROTECTION ANGLE:
REFLECTANCE Ceiling
0.8
0.8
0.8
0.7
0.7
0.7
0.5
0.5
0.5
0
Walls
0.7
0.5
0.3
0.7
0.5
0.3
0.7
0.5
0.3
0
Working plane
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0
ROOM INDEX
UTILIZATION FACTORS(PERCENT)
k(RI) x RCR = 5
k = 0.60
52
40
32
51
39
32
50
39
32
25
0.80
61
49
41
60
48
41
58
47
40
33
1.00
69
57
49
68
56
48
65
57
48
40
1.25
76
64
56
74
63
55
71
61
54
46
1.50
81
69
61
79
68
61
75
66
59
50
2.00
88
78
70
86
76
69
81
73
67
57
2.50
92
83
75
90
81
74
85
78
72
61
3.00
96
87
80
93
85
79
88
81
76
65
4.00
100
93
87
97
91
85
92
86
82
70
5.00
103
97
91
100
94
89
94
90
85
73
ROOM INDEX According to DIN EN 13032-2 2004
C Range: 0 - 360DEG C Interval: 45.0DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2014-08-28
E:\吸顶灯IES大全\QS-NC-CL24W\QS-NC-Cl24W-CW-4000K.GOS
UF(total)
Direct Suspended
g Range: 0 - 180DEG g Interval: 1.0DEG
SHRNOM = 1.25
Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.281 Humidity:65.0% Test Distance:6.200m [K=1.0000] Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT
Page 7 Of 11
ISOCANDELA DIAGRAM
NAME: QS-NC-CL24W-CW-4000K
TYPE:
WEIGHT:
SPEC.:
DIM.:
SERIAL No.:
MFR.: EVERFINE
SUR.:
PROTECTION ANGLE:
90
5% 10% 15% 20% 25% 30% 35% 40% 45% 50% 55% 60% 65% 70% 75% 80% 85% 90% 95%
80 70 60 50 40 30 VERTICAL(DEG)
20 10 0
20.09 40.18 60.27 80.36 100.5 120.5 140.6 160.7 180.8 200.9 221.0 241.1 261.2 281.3 301.4 321.5 341.5 361.6 381.7
-10 -20 -30 -40 -50 -60 -70 Imax:401.8(H2.0,V0.0) (At:C=0.0,Gamma=2.0)
-80 -90 -90 -80 -70 -60 -50 -40 -30 -20 -10
UNIT: cd 0
10
20
30
40
50
60
70
80
90
HORIZONTAL(DEG)
C Range: 0 - 360DEG C Interval: 45.0DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2014-08-28
E:\吸顶灯IES大全\QS-NC-CL24W\QS-NC-Cl24W-CW-4000K.GOS
g Range: 0 - 180DEG g Interval: 1.0DEG
Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.281 Humidity:65.0% Test Distance:6.200m [K=1.0000] Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT
Page 8 Of 11
AAI Figure
NAME: QS-NC-CL24W-CW-4000K
TYPE:
WEIGHT:
SPEC.:
DIM.:
SERIAL No.:
MFR.: EVERFINE
SUR.:
PROTECTION ANGLE:
Flux out:927.5 lm
3.281ft 1m
9.143,37.31fc 98.42,401.6lx
11.25ft 342.91cm
6.562ft 2m
2.286,9.327fc 24.60,100.4lx
22.5ft 685.83cm
9.843ft 3m
1.016,4.145fc 10.94,44.62lx
33.75ft 1028.74cm
13.12ft 4m
0.5714,2.332fc 6.151,25.10lx
45ft 1371.66cm
16.4ft 5m
0.3657,1.492fc 3.937,16.06lx
56.25ft 1714.57cm
Height
Eavg,Emax
Angle:119.50deg
Diameter
Note:The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance.
C Range: 0 - 360DEG C Interval: 45.0DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2014-08-28
E:\吸顶灯IES大全\QS-NC-CL24W\QS-NC-Cl24W-CW-4000K.GOS
g Range: 0 - 180DEG g Interval: 1.0DEG
Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.281 Humidity:65.0% Test Distance:6.200m [K=1.0000] Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT
Page 9 Of 11
ISOLUX DIAGRAM
NAME: QS-NC-CL24W-CW-4000K
TYPE:
WEIGHT:
SPEC.:
DIM.:
SERIAL No.:
MFR.: EVERFINE
SUR.:
PROTECTION ANGLE:
105.0'
52.5'
0.0'
52.5'
105.0'
131.2'
40.00m
105.0'
32.00m
78.7'
24.00m
52.5'
16.00m
26.2'
8.00m
0.0'
0.00m
26.2'
8.00m
52.5'
16.00m
78.7'
24.00m
105.0'
32.00m
3% 0.1205lx 0.01119fc 5% 0.2008lx 0.01865fc 10% 0.4016lx 0.03731fc 30% 1.205lx 0.1119fc
131.2'
50% 2.008lx 0.1865fc
40.00m 32.00m
16.00m
0.00m
16.00m
32.00m
MOUNTING HEIGHT: 33'(10.0m)
C Range: 0 - 360DEG C Interval: 45.0DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2014-08-28
E:\吸顶灯IES大全\QS-NC-CL24W\QS-NC-Cl24W-CW-4000K.GOS
g Range: 0 - 180DEG g Interval: 1.0DEG
Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.281 Humidity:65.0% Test Distance:6.200m [K=1.0000] Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT
Page 10 Of 11
Planar Illuminance Curve
Planar Illuminance Curve E(lx) 4.5
MH = 10 m C0/180 C90/270
4.05
3.6
3.15
2.7
2.25
1.8
1.35
0.9
0.45
0 -25
-20
-15
-10
-5
0
5
10
15
20
25
Distance(m)
C Range: 0 - 360DEG C Interval: 45.0DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2014-08-28
E:\吸顶灯IES大全\QS-NC-CL24W\QS-NC-Cl24W-CW-4000K.GOS
g Range: 0 - 180DEG g Interval: 1.0DEG
Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.281 Humidity:65.0% Test Distance:6.200m [K=1.0000] Remarks:
EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT
Page 11 Of 11
LUMINOUS DISTRIBUTION INTENSITY DATA
NAME: QS-NC-CL24W-CW-4000K
TYPE:
WEIGHT:
SPEC.:
DIM.:
SERIAL No.:
MFR.: EVERFINE
SUR.:
PROTECTION ANGLE:
Table--1 C(DEG)
UNIT: cd 0
45
90
135
180
225
270
315
0
402
399
397
395
402
399
397
395
5
401
400
397
394
399
395
394
394
10
397
397
394
389
393
388
388
389
15
391
391
388
382
383
378
378
381
20
381
382
378
371
371
365
366
370
25
368
370
366
357
356
349
350
355
30
351
355
350
340
337
330
332
338
35
332
337
331
321
317
309
311
319
40
311
316
310
299
293
285
288
297
45
287
293
287
275
269
260
263
273
50
262
268
262
250
243
235
238
248
55
236
242
237
224
218
209
213
223
60
211
217
211
199
193
185
188
198
65
186
191
186
175
168
161
164
173
70
161
167
162
151
144
138
140
150
75
138
143
139
128
123
116
119
128
80
117
121
118
107
102
96.4 98.6
85
96.8
101
97.4 88.2 83.0 77.5 79.9 87.7
90
77.8 81.9 78.5 70.5 65.6 60.6 62.9 69.7
95
60.8 64.6 61.5 54.8 50.5 46.1 48.2 54.0
100
46.2 49.6 46.9 41.3 37.6 33.8 35.6 40.5
105
33.9 36.9 34.6 30.1 27.0 23.9 25.2 29.3
110
23.9 26.5 24.6 21.1 18.8 16.3 17.2 20.5
115
16.2 18.3 16.9 14.4 12.7 10.8 11.4 13.8
120
10.7 12.2 11.4 9.64 8.55 7.22 7.64 9.23
125
6.98 8.09 7.72 6.63 5.96 5.06 5.40 6.32
130
4.73 5.46 5.44 4.76 4.40 4.20 4.21 4.64
135
3.47 3.81 3.89 3.54 4.27 4.25 4.27 4.23
140
3.60 3.58 3.59 3.67 4.34 4.32 4.33 4.29
145
3.78 3.77 3.77 3.85 4.40 4.39 4.40 4.36
150
3.97 3.95 3.95 4.02 4.49 4.46 4.47 4.44
155
4.15 4.13 4.13 4.19 4.57 4.54 4.56 4.52
160
4.31 4.30 4.30 4.35 4.65 4.62 4.64 4.60
165
4.47 4.46 4.45 4.51 4.72 4.70 4.72 4.68
170
4.60 4.60 4.59 4.64 4.77 4.74 4.76 4.74
175
4.70 4.70 4.69 4.74 4.79 4.76 4.79 4.77
180
4.77 4.77 4.77 4.80 4.79 4.76 4.78 4.78
g (DEG)
107
C Range: 0 - 360DEG C Interval: 45.0DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2014-08-28
E:\吸顶灯IES大全\QS-NC-CL24W\QS-NC-Cl24W-CW-4000K.GOS
g Range: 0 - 180DEG g Interval: 1.0DEG
Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.281 Humidity:65.0% Test Distance:6.200m [K=1.0000] Remarks: