Preview only show first 10 pages with watermark. For full document please download

Qs-nc-cl24w-cw, 4000k

   EMBED


Share

Transcript

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 11 LUMINAIRE PHOTOMETRIC TEST REPORT NAME: QS-NC-CL24W-CW-4000K TYPE: WEIGHT: SPEC.: DIM.: SERIAL No.: MFR.: EVERFINE SUR.: PROTECTION ANGLE: DATA OF LAMP PHOTOMETRIC DATA Eff: 68.61 lm/W MODEL QS-NC-CL24W-CW-4000K Imax(cd) 401.8 S/MH(C0/180) 1.30 NOMINAL POWER(W) 22 LOR(%) 100.0 S/MH(C90/270) 1.31 RATED VOLTAGE(V) 242 TOTAL FLUX(lm) 1458.9 h UP,DN(C0-180) 4.6,47.5 NOMINAL FLUX(lm) 1458.87 CIE CLASS DIRECT h UP,DN(C180-360) 3.8,44.1 LAMPS INSIDE 1 h up(%) 8.4 CIBSE SHR NOM 1.25 TEST VOLTAGE(V) 241.4 h down(%) 91.6 CIBSE SHR MAX 1.35 LUMINOUS INTENSITY DISTRIBUTION DIAGRAM C0 PLANE ISOLUX DIAGRAM (UNIT:lx) MH(m) 14 18 -/+180 -150 150 22 -120 120 26 30 0 -90 90 90 34 38 180 42 -60 270 360 -30 60 UNIT:cd C0/180,120.3deg C90/270,120.2deg 30 450 0 AVERAGE BEAM ANGLE(50%):120.2 DEG C Range: 0 - 360DEG C Interval: 45.0DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2014-08-28 E:\吸顶灯IES大全\QS-NC-CL24W\QS-NC-Cl24W-CW-4000K.GOS 46 0.0 16.5 2.40 2.00 1.60 1.20 0.8000 g Range: 0 - 180DEG g Interval: 1.0DEG 0.4000 0.3200 0.2000 0.1600 0.1200 33.0 S(m) Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.281 Humidity:65.0% Test Distance:6.200m [K=1.0000] Remarks: EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 2 Of 11 ZONAL FLUX DIAGRAM ZONAL FLUX DIAGRAM: g g F zone F total C0 C45 C90 C135 C180 C225 C270 C315 %lum,lamp 10 397.5 397.1 394.1 389.5 392.7 388.4 387.7 388.9 0- 10 37.72 37.72 2.59,2.59 20 380.7 382.2 378.2 370.9 371.0 365.2 365.7 369.7 10- 20 108.4 146.1 10,10 30 351.4 354.7 349.8 340.2 337.4 329.9 331.8 338.4 20- 30 165.4 311.5 21.4,21.4 40 310.8 315.7 310.3 298.6 293.5 285.0 287.8 296.7 30- 40 201.5 513.0 35.2,35.2 50 261.9 267.8 262.2 249.9 243.2 234.7 237.8 247.9 40- 50 212.9 725.9 49.8,49.8 60 210.7 216.7 211.4 199.2 192.6 184.5 187.6 197.8 50- 60 201.7 927.5 63.6,63.6 70 161.4 167.0 162.3 150.9 144.5 137.7 140.2 150.1 60- 70 174.0 1102 75.5,75.5 80 116.9 121.3 117.6 107.5 102.1 96.36 98.58 107.2 70- 80 136.9 1239 84.9,84.9 90 77.84 81.87 78.54 70.48 65.62 60.56 62.90 69.67 80- 90 97.24 1336 91.6,91.6 100 46.18 49.60 46.87 41.30 37.59 33.83 35.58 40.49 90-100 60.52 1396 95.7,95.7 110 23.93 26.46 24.63 21.14 18.76 16.32 17.23 20.49 100-110 32.36 1429 97.9,97.9 120 10.68 12.24 11.42 9.640 8.552 7.217 7.635 9.228 110-120 14.65 1443 98.9,98.9 130 4.727 5.460 5.444 4.761 4.399 4.197 4.210 4.645 120-130 6.081 1449 99.3,99.3 140 3.602 3.584 3.592 3.673 4.339 4.316 4.326 4.288 130-140 3.189 1453 99.6,99.6 150 3.966 3.949 3.954 4.022 4.488 4.460 4.473 4.435 140-150 2.566 1455 99.7,99.7 160 4.314 4.304 4.296 4.354 4.646 4.620 4.638 4.597 150-160 2.008 1457 99.9,99.9 170 4.597 4.597 4.592 4.635 4.770 4.739 4.764 4.739 160-170 1.296 1458 100,100 180 4.770 4.775 4.767 4.802 4.790 4.762 4.782 4.780 170-180 0.4507 1459 100,100 DEG LUMINOUS INTENSITY:cd C Range: 0 - 360DEG C Interval: 45.0DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2014-08-28 E:\吸顶灯IES大全\QS-NC-CL24W\QS-NC-Cl24W-CW-4000K.GOS g Range: 0 - 180DEG g Interval: 1.0DEG UNIT:lm Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.281 Humidity:65.0% Test Distance:6.200m [K=1.0000] Remarks: EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 3 Of 11 CU AND LUMINAIRE BUDGETARY ESTIMATE DIAGRAM NAME: QS-NC-CL24W-CW-4000K TYPE: WEIGHT: SPEC.: DIM.: SERIAL No.: MFR.: EVERFINE SUR.: PROTECTION ANGLE: r cc 80% rw 50% 30% r fc 70% 10% 50% 20% RCR 30% 50% 10% 50% 20% RCR:Room Cavity Ratio 30% 30% 10% 50% 20% 30% 10% 10% 50% 20% 30% 0 10% 20% 0 0 Coefficients of Utilization(CU) 0.0 1.17 1.17 1.17 1.13 1.13 1.13 1.06 1.06 1.06 1.00 1.00 1.00 .94 .94 .94 .92 1.0 .99 .93 .89 .95 .91 .86 .89 .86 .82 .84 .81 .78 .79 .77 .74 .71 2.0 .85 .77 .70 .82 .75 .69 .77 .71 .66 .72 .67 .63 .68 .64 .61 .58 3.0 .74 .65 .58 .71 .63 .57 .67 .60 .54 .63 .57 .52 .60 .55 .50 .48 4.0 .65 .56 .48 .63 .54 .48 .59 .52 .46 .56 .50 .44 .53 .47 .43 .40 5.0 .58 .48 .41 .56 .47 .41 .53 .45 .39 .50 .43 .38 .47 .42 .37 .35 6.0 .52 .43 .36 .50 .42 .35 .48 .40 .34 .45 .38 .33 .43 .37 .32 .30 7.0 .47 .38 .31 .46 .37 .31 .43 .36 .30 .41 .34 .29 .39 .33 .29 .26 8.0 .43 .34 .28 .42 .33 .28 .40 .32 .27 .38 .31 .26 .36 .30 .26 .23 9.0 .39 .31 .25 .38 .30 .25 .36 .29 .24 .35 .28 .24 .33 .27 .23 .21 10.0 .36 .28 .23 .35 .28 .22 .34 .27 .22 .32 .26 .21 .31 .25 .21 .19 LAMPS 50 LUMINAIRE BUDGETARY DIAGRAM 40 30 20 H=8 7 10 9 8 7 6 CONDITIONS FLUX 2000lm FACTOR 0.70 Hdown 0.00m Hwork 0.80m Ework(AVE) 100lx cc w fc r (%) 70 50 30 50 30 20 6 5 5 4 H=5 3 4 2 10 2 3 20 30 40 50 70 100 C Range: 0 - 360DEG C Interval: 45.0DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2014-08-28 E:\吸顶灯IES大全\QS-NC-CL24W\QS-NC-Cl24W-CW-4000K.GOS 200 300 AREA(m2) 500 700 g Range: 0 - 180DEG g Interval: 1.0DEG 1k 2k 3k 4k 5k 7k Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.281 Humidity:65.0% Test Distance:6.200m [K=1.0000] Remarks: EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 4 Of 11 WEC AND CCEC NAME: QS-NC-CL24W-CW-4000K TYPE: WEIGHT: SPEC.: DIM.: SERIAL No.: MFR.: EVERFINE SUR.: PROTECTION ANGLE: r cc rw 80% 50% r fc RCR 30% 70% 10% 50% 20% 30% 50% 10% 50% 20% 30% 30% 10% 50% 20% RCR:Room Cavity Ratio 30% 10% 10% 50% 20% 30% 0 10% 20% 0 0 Wall Exitance Coeffcients(WEC) 0.0 1.0 .374 .212 .067 .364 .208 .066 .345 .198 .063 .329 .189 .061 .313 .181 .058 2.0 .328 .180 .055 .319 .176 .054 .302 .168 .052 .287 .161 .050 .273 .155 .049 3.0 .293 .156 .047 .285 .153 .046 .270 .147 .045 .257 .141 .043 .244 .135 .042 4.0 .265 .138 .040 .258 .135 .040 .245 .130 .039 .232 .125 .038 .221 .120 .037 5.0 .242 .123 .036 .235 .121 .035 .223 .116 .034 .212 .112 .033 .202 .108 .032 6.0 .222 .111 .032 .216 .109 .031 .205 .105 .031 .195 .101 .030 .186 .098 .029 7.0 .205 .101 .029 .200 .100 .028 .190 .096 .028 .181 .093 .027 .172 .089 .026 8.0 .190 .093 .026 .186 .091 .026 .177 .088 .025 .168 .085 .025 .161 .082 .024 9.0 .178 .086 .024 .173 .084 .024 .165 .082 .023 .158 .079 .023 .150 .076 .022 10.0 .166 .080 .022 .162 .078 .022 .155 .076 .021 .148 .073 .021 .141 .071 .020 r cc rw r fc RCR 80% 50% 30% 70% 10% 20% 50% 30% 50% 10% 20% RCR:Room Cavity Ratio 50% 30% 20% 30% 10% 50% 30% 20% 10% 10% 50% 30% 0 10% 20% 0 0 Ceiling Cavity Exitance Coefficients(CCEC) 0.0 .255 .255 .255 .218 .218 .218 .149 .149 .149 .085 .085 .085 .027 .027 .027 1.0 .250 .220 .194 .214 .189 .167 .146 .130 .116 .084 .075 .067 .027 .024 .022 2.0 .242 .197 .159 .208 .170 .137 .142 .117 .096 .082 .068 .056 .026 .022 .018 3.0 .235 .180 .137 .201 .155 .118 .138 .108 .083 .080 .063 .049 .026 .020 .016 4.0 .227 .167 .122 .194 .145 .106 .134 .101 .075 .077 .059 .044 .025 .019 .015 5.0 .219 .157 .112 .188 .136 .097 .129 .095 .069 .075 .056 .041 .024 .018 .013 6.0 .211 .149 .104 .182 .129 .091 .125 .090 .064 .073 .053 .038 .023 .017 .013 7.0 .204 .142 .099 .176 .123 .086 .121 .086 .061 .071 .051 .036 .023 .017 .012 8.0 .197 .137 .095 .170 .118 .083 .118 .083 .059 .068 .049 .035 .022 .016 .012 9.0 .191 .132 .092 .165 .114 .080 .114 .080 .057 .066 .047 .034 .022 .016 .011 10.0 .185 .127 .089 .160 .111 .078 .111 .078 .055 .065 .046 .033 .021 .015 .011 C Range: 0 - 360DEG C Interval: 45.0DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2014-08-28 E:\吸顶灯IES大全\QS-NC-CL24W\QS-NC-Cl24W-CW-4000K.GOS g Range: 0 - 180DEG g Interval: 1.0DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.281 Humidity:65.0% Test Distance:6.200m [K=1.0000] Remarks: EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 5 Of 11 Uncorrected UGR Table NAME: QS-NC-CL24W-CW-4000K TYPE: WEIGHT: SPEC.: DIM.: SERIAL No.: MFR.: EVERFINE SUR.: PROTECTION ANGLE: ceiling/cavity 0.7 0.7 0.5 0.5 0.3 0.7 0.7 0.5 0.5 0.3 walls 0.5 0.3 0.5 0.3 0.3 0.5 0.3 0.5 0.3 0.3 working plane 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 Room dimensions x = 2H y = 4H 8H 12H Viewed crosswise Viewed endwise 2H 21.6 23.1 22.0 23.5 23.8 21.6 23.1 22.0 23.5 23.8 3H 23.7 25.1 24.1 25.5 25.9 23.7 25.1 24.1 25.5 25.9 4H 24.8 26.1 25.2 26.5 26.9 24.8 26.1 25.2 26.5 27.0 6H 25.9 27.2 26.4 27.6 28.1 26.0 27.2 26.4 27.6 28.1 8H 26.6 27.8 27.0 28.2 28.7 26.6 27.8 27.1 28.2 28.7 12H 27.3 28.4 27.8 28.9 29.4 27.3 28.5 27.8 28.9 29.4 2H 22.4 23.7 22.8 24.1 24.5 22.4 23.7 22.8 24.1 24.5 3H 24.7 25.8 25.2 26.3 26.8 24.7 25.8 25.2 26.3 26.8 4H 25.9 27.0 26.4 27.5 28.0 26.0 27.0 26.5 27.5 28.0 6H 27.3 28.2 27.8 28.7 29.3 27.3 28.3 27.8 28.8 29.3 8H 28.0 28.9 28.6 29.4 30.0 28.0 28.9 28.6 29.4 30.0 12H 28.8 29.7 29.4 30.2 30.8 28.9 29.7 29.4 30.2 30.8 4H 26.5 27.3 27.0 27.9 28.4 26.5 27.4 27.0 27.9 28.5 6H 28.1 28.8 28.7 29.4 30.0 28.1 28.9 28.7 29.4 30.0 8H 29.0 29.7 29.6 30.2 30.9 29.0 29.7 29.6 30.3 30.9 12H 30.0 30.6 30.7 31.2 31.9 30.1 30.7 30.7 31.3 31.9 4H 26.6 27.4 27.1 27.9 28.5 26.6 27.4 27.1 27.9 28.5 6H 28.3 29.0 28.9 29.6 30.2 28.3 29.0 28.9 29.6 30.2 8H 29.3 29.9 29.9 30.5 31.2 29.4 29.9 30.0 30.5 31.2 Variations with the observer position at spacings: S = 1.0H + 0.1 / - 0.1 + 0.1 / - 0.1 1.5H + 0.2 / - 0.3 + 0.2 / - 0.3 2.0H + 0.2 / - 0.4 + 0.2 / - 0.4 CIE Pub.117 Corrected 1459 lm Total Lamp Luminous Flux.(8log(F/F0) = 1.3) C Range: 0 - 360DEG C Interval: 45.0DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2014-08-28 E:\吸顶灯IES大全\QS-NC-CL24W\QS-NC-Cl24W-CW-4000K.GOS g Range: 0 - 180DEG g Interval: 1.0DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.281 Humidity:65.0% Test Distance:6.200m [K=1.0000] Remarks: EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 6 Of 11 UTILIZATION FACTORS TABLE NAME: QS-NC-CL24W-CW-4000K TYPE: WEIGHT: SPEC.: DIM.: SERIAL No.: MFR.: EVERFINE SUR.: PROTECTION ANGLE: REFLECTANCE Ceiling 0.8 0.8 0.8 0.7 0.7 0.7 0.5 0.5 0.5 0 Walls 0.7 0.5 0.3 0.7 0.5 0.3 0.7 0.5 0.3 0 Working plane 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0 ROOM INDEX UTILIZATION FACTORS(PERCENT) k(RI) x RCR = 5 k = 0.60 52 40 32 51 39 32 50 39 32 25 0.80 61 49 41 60 48 41 58 47 40 33 1.00 69 57 49 68 56 48 65 57 48 40 1.25 76 64 56 74 63 55 71 61 54 46 1.50 81 69 61 79 68 61 75 66 59 50 2.00 88 78 70 86 76 69 81 73 67 57 2.50 92 83 75 90 81 74 85 78 72 61 3.00 96 87 80 93 85 79 88 81 76 65 4.00 100 93 87 97 91 85 92 86 82 70 5.00 103 97 91 100 94 89 94 90 85 73 ROOM INDEX According to DIN EN 13032-2 2004 C Range: 0 - 360DEG C Interval: 45.0DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2014-08-28 E:\吸顶灯IES大全\QS-NC-CL24W\QS-NC-Cl24W-CW-4000K.GOS UF(total) Direct Suspended g Range: 0 - 180DEG g Interval: 1.0DEG SHRNOM = 1.25 Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.281 Humidity:65.0% Test Distance:6.200m [K=1.0000] Remarks: EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 7 Of 11 ISOCANDELA DIAGRAM NAME: QS-NC-CL24W-CW-4000K TYPE: WEIGHT: SPEC.: DIM.: SERIAL No.: MFR.: EVERFINE SUR.: PROTECTION ANGLE: 90 5% 10% 15% 20% 25% 30% 35% 40% 45% 50% 55% 60% 65% 70% 75% 80% 85% 90% 95% 80 70 60 50 40 30 VERTICAL(DEG) 20 10 0 20.09 40.18 60.27 80.36 100.5 120.5 140.6 160.7 180.8 200.9 221.0 241.1 261.2 281.3 301.4 321.5 341.5 361.6 381.7 -10 -20 -30 -40 -50 -60 -70 Imax:401.8(H2.0,V0.0) (At:C=0.0,Gamma=2.0) -80 -90 -90 -80 -70 -60 -50 -40 -30 -20 -10 UNIT: cd 0 10 20 30 40 50 60 70 80 90 HORIZONTAL(DEG) C Range: 0 - 360DEG C Interval: 45.0DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2014-08-28 E:\吸顶灯IES大全\QS-NC-CL24W\QS-NC-Cl24W-CW-4000K.GOS g Range: 0 - 180DEG g Interval: 1.0DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.281 Humidity:65.0% Test Distance:6.200m [K=1.0000] Remarks: EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 8 Of 11 AAI Figure NAME: QS-NC-CL24W-CW-4000K TYPE: WEIGHT: SPEC.: DIM.: SERIAL No.: MFR.: EVERFINE SUR.: PROTECTION ANGLE: Flux out:927.5 lm 3.281ft 1m 9.143,37.31fc 98.42,401.6lx 11.25ft 342.91cm 6.562ft 2m 2.286,9.327fc 24.60,100.4lx 22.5ft 685.83cm 9.843ft 3m 1.016,4.145fc 10.94,44.62lx 33.75ft 1028.74cm 13.12ft 4m 0.5714,2.332fc 6.151,25.10lx 45ft 1371.66cm 16.4ft 5m 0.3657,1.492fc 3.937,16.06lx 56.25ft 1714.57cm Height Eavg,Emax Angle:119.50deg Diameter Note:The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance. C Range: 0 - 360DEG C Interval: 45.0DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2014-08-28 E:\吸顶灯IES大全\QS-NC-CL24W\QS-NC-Cl24W-CW-4000K.GOS g Range: 0 - 180DEG g Interval: 1.0DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.281 Humidity:65.0% Test Distance:6.200m [K=1.0000] Remarks: EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 9 Of 11 ISOLUX DIAGRAM NAME: QS-NC-CL24W-CW-4000K TYPE: WEIGHT: SPEC.: DIM.: SERIAL No.: MFR.: EVERFINE SUR.: PROTECTION ANGLE: 105.0' 52.5' 0.0' 52.5' 105.0' 131.2' 40.00m 105.0' 32.00m 78.7' 24.00m 52.5' 16.00m 26.2' 8.00m 0.0' 0.00m 26.2' 8.00m 52.5' 16.00m 78.7' 24.00m 105.0' 32.00m 3% 0.1205lx 0.01119fc 5% 0.2008lx 0.01865fc 10% 0.4016lx 0.03731fc 30% 1.205lx 0.1119fc 131.2' 50% 2.008lx 0.1865fc 40.00m 32.00m 16.00m 0.00m 16.00m 32.00m MOUNTING HEIGHT: 33'(10.0m) C Range: 0 - 360DEG C Interval: 45.0DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2014-08-28 E:\吸顶灯IES大全\QS-NC-CL24W\QS-NC-Cl24W-CW-4000K.GOS g Range: 0 - 180DEG g Interval: 1.0DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.281 Humidity:65.0% Test Distance:6.200m [K=1.0000] Remarks: EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 10 Of 11 Planar Illuminance Curve Planar Illuminance Curve E(lx) 4.5 MH = 10 m C0/180 C90/270 4.05 3.6 3.15 2.7 2.25 1.8 1.35 0.9 0.45 0 -25 -20 -15 -10 -5 0 5 10 15 20 25 Distance(m) C Range: 0 - 360DEG C Interval: 45.0DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2014-08-28 E:\吸顶灯IES大全\QS-NC-CL24W\QS-NC-Cl24W-CW-4000K.GOS g Range: 0 - 180DEG g Interval: 1.0DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.281 Humidity:65.0% Test Distance:6.200m [K=1.0000] Remarks: EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 11 Of 11 LUMINOUS DISTRIBUTION INTENSITY DATA NAME: QS-NC-CL24W-CW-4000K TYPE: WEIGHT: SPEC.: DIM.: SERIAL No.: MFR.: EVERFINE SUR.: PROTECTION ANGLE: Table--1 C(DEG) UNIT: cd 0 45 90 135 180 225 270 315 0 402 399 397 395 402 399 397 395 5 401 400 397 394 399 395 394 394 10 397 397 394 389 393 388 388 389 15 391 391 388 382 383 378 378 381 20 381 382 378 371 371 365 366 370 25 368 370 366 357 356 349 350 355 30 351 355 350 340 337 330 332 338 35 332 337 331 321 317 309 311 319 40 311 316 310 299 293 285 288 297 45 287 293 287 275 269 260 263 273 50 262 268 262 250 243 235 238 248 55 236 242 237 224 218 209 213 223 60 211 217 211 199 193 185 188 198 65 186 191 186 175 168 161 164 173 70 161 167 162 151 144 138 140 150 75 138 143 139 128 123 116 119 128 80 117 121 118 107 102 96.4 98.6 85 96.8 101 97.4 88.2 83.0 77.5 79.9 87.7 90 77.8 81.9 78.5 70.5 65.6 60.6 62.9 69.7 95 60.8 64.6 61.5 54.8 50.5 46.1 48.2 54.0 100 46.2 49.6 46.9 41.3 37.6 33.8 35.6 40.5 105 33.9 36.9 34.6 30.1 27.0 23.9 25.2 29.3 110 23.9 26.5 24.6 21.1 18.8 16.3 17.2 20.5 115 16.2 18.3 16.9 14.4 12.7 10.8 11.4 13.8 120 10.7 12.2 11.4 9.64 8.55 7.22 7.64 9.23 125 6.98 8.09 7.72 6.63 5.96 5.06 5.40 6.32 130 4.73 5.46 5.44 4.76 4.40 4.20 4.21 4.64 135 3.47 3.81 3.89 3.54 4.27 4.25 4.27 4.23 140 3.60 3.58 3.59 3.67 4.34 4.32 4.33 4.29 145 3.78 3.77 3.77 3.85 4.40 4.39 4.40 4.36 150 3.97 3.95 3.95 4.02 4.49 4.46 4.47 4.44 155 4.15 4.13 4.13 4.19 4.57 4.54 4.56 4.52 160 4.31 4.30 4.30 4.35 4.65 4.62 4.64 4.60 165 4.47 4.46 4.45 4.51 4.72 4.70 4.72 4.68 170 4.60 4.60 4.59 4.64 4.77 4.74 4.76 4.74 175 4.70 4.70 4.69 4.74 4.79 4.76 4.79 4.77 180 4.77 4.77 4.77 4.80 4.79 4.76 4.78 4.78 g (DEG) 107 C Range: 0 - 360DEG C Interval: 45.0DEG Test Speed: HIGH Temperature:25.3DEG Operators:DAMIN Test Date:2014-08-28 E:\吸顶灯IES大全\QS-NC-CL24W\QS-NC-Cl24W-CW-4000K.GOS g Range: 0 - 180DEG g Interval: 1.0DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V2.0.281 Humidity:65.0% Test Distance:6.200m [K=1.0000] Remarks: