Preview only show first 10 pages with watermark. For full document please download

Qsfp+ Passive Copper

   EMBED


Share

Transcript

QSFP+ Passive Copper Cable Assemblies www.meritec.com  • 1-888-MERITEC (637-4832)  • 440-354-2100 Features & Benefits • Enhanced EMI shielding for low emissions • Ultra-low crosstalk for enhanced performance • Mates with all standard QSFP interfaces • Supports belly-to-belly applications • RoHS compliant • Lower cost alternative to fiber optics • Multiple conductor sizes available to achieve maximum performance • Programmable EEPROM • Compliant with all relevant IEEE & SFF specifications Specifications Electrical • Supports/Exceeds 40 Gb/s Ethernet IEEE802.3ba (4 x 10 Gb/s) • Supports IBTA QDR (4 x 10 Gb/s) • Supports IBTA FDR (4 x 14 Gb/s) • Exceeds performance of SFF-8436 requirements • Fully shielded assembly • Shielded twinax cable construction with drain wire • 100 ohm impedance matching to within 5 ohms to ensure interoperability Mechanical • Die cast metal housings • 200 plus mating cycles • Ergonomic pull-style latch to de-latch, push-to-latch • Unique strain relief design, protects termination from mechanical stress • Positive latching mechanism Environmental LCP UL 94V-O rated • Resin material: • Temperature range: –20°C to +80°C Meritec 1359 West Jackson Street Painesville, Ohio 44077 USA 800-860-9014 888-MERITEC (637-4832) Office: 440-354-2100 Fax: 440-354-5692 www.meritec.com [email protected] © Meritec 052013 Document Number 2081-0139113 QSFP+ Passive Copper Cable Assemblies WIRING DIAGRAM P1 END P2 END PAD SIGNAL PAD SIGNAL 01 GND 20 GND 02 TX2n 21 RX2n 03 TX2p 22 RX2p 04 GND 23 GND 05 TX4n 24 RX4n 06 TX4p 25 RX4p 07 GND 26 GND 13 GND 32 GND 14 RX3p 33 TX3p 15 RX3n 34 TX3n 16 GND 35 GND 17 RX1p 36 TX1p 18 RX1n 37 TX1n 19 GND 38 GND 20 GND 01 GND 21 RX2n 02 TX2n 22 RX2p 03 TX2p 23 GND 04 GND 24 RX4n 05 TX4n 25 RX4p 06 TX4p 26 GND 07 GND 32 GND 13 GND 33 TX3p 14 RX3p 34 TX3n 15 RX3n 35 GND 16 GND 36 TX1p 17 RX1p 37 TX1n 18 RX1n 38 GND 19 GND PAD 20 LENGTH 86.05 18.35±0.1 P1 PAD 38 P2 8.5±0.1 PAD 19 PAD 01 CHART SUFFIX LENGTH IN METERS QDR (10 Gb/s) / FDR (14 Gb/s) A= 24 AWG B= 26 AWG C= 28 AWG D= 30 AWG 7 5 3 1 TOLERANCE @ MAXIMUM LENGTH ± 70.0 mm ± 70.0 mm ± 70.0 mm ± 70.0 mm 5 4 3 1 NOTE: TOLERANCE OF ± 40.0mm FOR LENGTHS OF 0.5M TO 1.0M CONSULT FACTORY FOR LENGTHS LESS THAN 0.5M PART NUMBER ORDERING SPECIFICATION: CHOOSE ONE: QDR FDR 9846 9849 - CHART SUFFIX (AWG) . LENGTH IN METERS CONFIDENTIAL AND PROPRIETARY NOTICE This document and the information contained in it are confidential property of Meritec. The document and information are provided to you for your review and evaluation and must not be furnished or disclosed to others without prior written consent by an authorized representative of Meritec. © Meritec 2013  All rights reserved.2081-0139113 —  2  —