Preview only show first 10 pages with watermark. For full document please download

Quanta System Light Series Laser

   EMBED


Share

Transcript

DERMATOLOGY AND AESTHETIC MEDICINE MEDICAL DIVISION Light Series Clinic in a System Dermatologic Platform Multiple Wavelengths for the higher Challenges in Laser Applications PERMANENT HAIR REDUCTION DERMATOLOGICAL VASCULAR LESIONS REMOVAL INFLAMMATORY ACNE TREATMENTS NON-ABLATIVE SKIN TREATMENTS SKIN REJUVENATION PROCEDURES ABLATIVE FRACTIONAL SKIN RESURFACING (TWAIN 2940) This brochure is not intended for the USA market. Certain Intended Uses/Configurations/Models/Accessories are not cleared for USA Multiple Wavelengths for the higher Challenges in Laser Applications Light Series has been developed to satisfy the needs of doctors and clinics, which today can perform a wide range of dermatologic and aesthetic applications by using a single device, instead of purchasing different lasers. The system can include different laser sources, such as a long pulsed Alexandrite (755 nm), a long and short pulsed Nd:Yag 1064 nm, a long pulsed Nd:Yag 532 nm and long pulsed 1320 nm. The large variety of available handpieces, with different variable and fixed spot sizes, gives the possibility to perform quick treatments by choosing an appropriate fluence. The laser emission parameters can PWS LIGHT SERIES & APPLICATIONS Light A Alexandrite (755 nm) long pulsed laser. Applications: • Permanent hair reduction of I-IV skin phototypes • Benign pigmented lesions removal Light B Nd:Yag (1064 nm) short and long pulsed laser. Applications: • Permanent hair reduction of every skin phototypes • Dermatological vascular treatments • Skin rejuvenation procedures Light A* (Star) This platform combines the Light A and Light B performances. It operates both at 755 and 1064 nm, be easily set allowing effective treatments of any skin type. Light Series, via a TWAIN connector, can be upgraded with a Er:Yag 2940 nm and IPL handpiece enhancing the treatment flexibility and versatility. Due to its modularity and flexibility, the NEW Light Series allows a quick return of investment. allowing the treatments as described for the Light A and B, respectively. Light C Combination of Nd:Yag 1064 nm short and long pulsed and Nd:Yag 532 nm long pulsed. In addition to the treatments performed with Light B, Light C is indicated for treatments such as: • Dermatological vascular lesions • Skin rejuvenation • Benign pigmented lesions Light 4 V Combination of Alexandrite (755 nm), Nd:Yag 1064 nm short and long pulsed and Nd:Yag 532 nm long pulsed. A complete system which allows to perform all the treatments indicated with LIGHT A, LIGHT B and LIGHT C. Ultralight Combination of Q-Switched Nd:Yag 1064 and 532 nm plus Nd:Yag 1064 nm short and long pulsed and Nd:Yag 532 nm long pulsed, all in one unit. The only system with 1064 + 532, both Q-Switched and long pulsed Nd:Yag laser, available on the market. In addition to the treatments performed with LIGHT C, this system can be used for: • Multicoloured tattoo removal • Benign epidermal and dermal pigmented lesions removal. Up to four wavelengths “all in one unit” for the maximum flexibility. OPTIONS Twain IPL Light Series can be equipped, at any treatment time, with an optional IPL, enhancing flexibility and versatility. Applications: • Permanent hair reduction • Benign pigmented lesions removal • Skin rejuvenation procedures • Dermatological vascular treatments • Inflammatory acne treatments Twain 2940 Optional for each series is an Erbium Yag laser all built into an handpiece. Through this module both fractional and traditional ablative skin resurfacing procedures are possible. This TWAIN represents the ideal solution for fast skin texture and wrinkle improvement. Nd:Yag 1320 (Light A* Star) Optional for any long pulsed Nd:Yag of this Series is the 1320 nm wavelength. Due to its higher absorption by water and great penetration into the dermis, it is very effective for nonablative skin treatments. Applications: • Ablative Fractional Resurfacing • Skin peels • Removal of benign skin lesions Twain IPL handpiece 2-5 mm variable spot size handpiece Twain 2940 handpiece Integrated optional contact skin cooler CLINICAL RESULTS PERMANENT HAIR REDUCTION BENIGN PIGMENTED LESIONS Courtesy of E. Bonizzoni MD Before After 5 treatments Before SKIN REJUVENATION DERMATOLOGICAL VASCULAR LESIONS Courtesy of P. Sbano MD Courtesy of E. Bonizzoni MD Before MODEL Permanent hair reduction After After 3 treatment Light A Light B Before Light A * Light C After Light 4V Ultralight Twain IPL Twain 2940 Nd:Yag 1320 • • • • • • • • • • • • • • • • • • • • • • • • • • • Dermatological vascular lesions Skin rejuvenation Fractional ablative rejuvenation Benign epidermal pigmented lesions removal Benign dermal pigmented lesions removal Tattoo removal Surgical dermatology VISIBLE AND INVISIBLE LASER RADIATION Avoid eye skin exposure to direct or scattered radiation Laser product: Class 4 Aiming beam: Class 3R CAUTION - Laser radiation DERMATOLOGY AND AESTHETIC MEDICINE MEDICAL DIVISION Light Series MODEL Light A Light B Light A* Laser Alexandrite Nd:Yag Pulse width [ms] 2-100 2-100 0.3-1 2-100 3-300 0.3-1 3-300 0.3-1 up to 25 Repetition rate [Hz] up to 2 up to 2 up to 7 up to 2 up to 2 up to 7 up to 2 up to 7 1 up to 16 up to 14 up to 6 up to 16 up to 14 up to 6 up to 14 up to 6 up to 6 up to 123 @ 6 mm >800 @ 2 mm up to 30 @ 5 mm up to 123 @ 6 mm >800 @ 2 mm up to 30 @ 5 mm >800 @ 2 mm up to 30 @ 5 mm up to 95 @ 2 mm [mm] 755 Nd:Yag [nm] Max fluence [J/cm2] 1064 long pulse 1064 short pulse Nd:Yag Wavelength Spot size 755 Light C 1064 long pulse 1064 short pulse 1064 long pulse 1064 short pulse 532 contact or air integrated with the handpiece (1) Skin Cooler Electrical requirements 230 V ac; 16 A; 50/60 Hz Dimensions and weight 480(W) x 900 (D) x 930 (H) mm; 90 Kg (1) Optional MODEL Light 4 V Laser Alexandrite Wavelength [nm] 755 Pulse width [ms] 2-100 Ultralight Nd:Yag Nd:Yag 1064 long pulse 1064 short pulse 2-100 0.3-1 532 Q-Switched Nd:Yag 1064 long pulse 1064 short pulse up to 25 2-100 0.3-1 532 1064 532 up to 25 6 ns 6 ns [Hz] up to 2 up to 2 up to 7 1 up to 2 up to 7 1 up to 10 up to 10 [mm] up to 16 up to 14 up to 6 up to 6 up to 14 up to 6 up to 6 up to 5x5 up to 5x5 [J/cm2] Max fluence up to 123 @ 6 mm >800 @ 2 mm up to 30 @ 5 mm up to 95 @ 2 mm >800 @ 2 mm up to 30 @ 5 mm up to 95 @ 2 mm 22 @ 2x2 mm 11 @ 2x2 mm Repetition rate Spot size Skin Cooler contact or air integrated with the handpiece (1) Electrical requirements 230 V ac; 16 A; 50/60 Hz Dimensions and weight 480(W) x 900 (D) x 930 (H) mm; 90 Kg (1) Optional OPTION Source Twain 2940 Twain IPL Er:Yag IPL handpieces Wavelength [nm] 2940 Pulse width [ms] 0.3 - 1 Spot size Max Fluence Repetition rate [mm] 2, 4, 9, fractional [J/cm2] 95 [Hz] up to 6 650-1200 625-1200 590-1200 570-1200 550-1200 400-1200 5 - 240 48x13 mm2 - 25x13 mm2 up to 30 0,5 0,5 0,5 0,5 0,5 0,5 Nd:Yag 1320 (2) Nd:Yag 1320 5 - 10 8 - 10 up to 20 @ 8 mm up to 5 (2) Nd:Yag 1320 option available for Light A*, Light B, Light C, Light 4 V Quanta System products are manufactured according to the International standards and have been cleared by the most important International notified bodies. The Company is EN ISO 9001:2008 and EN ISO 13485:2012 certified. Quanta System S.p.A. was founded in 1985 and belongs to the EI. En. Group (a public company listed in the Star segment of the Italian Stock Exchange) since January 2004. The company, divided into three business units (medical, scientific and industrial) is specialized in manufacturing of laser and opto-electronic devices. Quanta System S.p.A Via IV Novembre, 116 - 21058 Solbiate Olona (VA) Italy Tel. +39 0331.376797 - Fax +39 0331.367815 [email protected] www.quantasystem.com QTS-LIGHTSERIES-rev005 - ROTW Note: National local authorities may put restrictions to the parameters indicated in the above table, or may limit or remove certain intended uses. Specifications are subject to change without notice.