CONTENTS Cat5e Cabling Cat5e PVC Cable..............................4-5 Cat5e LSZH Cable............................6-7 Cat5e External Cable........................8-9
Cat5e Modules Cat5e Euro Module........................10-11 Cat5e LJ6C Module.......................12-13
Cat5e Patch Panels Cat5e Unshielded Patch Panel......14-15 Cat5e Unshielded Right Angled Patch Panel...................................16-17
Cat6 Cabling Cat6 LSZH Cable...........................18-19
Cat6 Modules Cat6 Euro Module..........................20-21 Cat6 LJ6C Module.........................22-23
Cat6 Patch Panels Cat6 Unshielded Patch Panel........24-25 Cat6 Unshielded Right Angled Patch Panel...................................26-27 Voice Panel...................................28-29
Warrenty Certificate
30
Quantum Cat5e PVC Cable, Grey 305m Box, 4 Pair 24AWG U/UTP / Part No.QTM - 0625305 Description
Application 100Base-T4 100Base-TX 100VG-AnyLAN 1000Base-T 1000Base-TX 155Mbps ATM 622Mbps ATM
Rated temperature:75 c Reference standard: UL444, TIA/EIA-568-B.2 & ISO 11801 Product standard certification: UL Flame test: CMX Solid bare copper conductor Colour-coded PE insulation PVC jacket
Product figure
Physical characteristics Structure Conductor
Insulation
Construction
U/UTP
Number of Pairs
4 Pairs
AWG
24 AWG
Conductor material
Solid bare copper
Conductor dimension
0.505 ±0.02 mm
Insulation material
HDPE
Insulation dimension
0.88 ±0.05 mm
Number colour
1.White/Blue(Stripe) & Blue
(Stripe marking)
2.White/Orange(Stripe) & Orange 3.White/Green(Stripe) & Green
Twisting lay length
Filler
Filler material
Binder
Binder material
N/A
Shield
Individual shield & material
N/A
Primary overall shield & material
N/A
Cabling lay length
Outer jacket
N/A
Shield coverage
N/A
Drain wire
N/A
Outer jacket material
PVC
Outer jacket thickness (Nom)
0.5mm
Overall nominal dimension
4.8 ±0.3 mm
Outer jacket colour
RAL7032
Outer jacket rip cord
YES
Mechanical
Operating temperature range
-20 c ~ +75 c
characteristics
Bulk cable weight
29 kg/km
Max. recommended pulling tension
110 N
Min. bend radius (install)
4 x O.D. < 13.8 MPa = < 100% =
Outer jacket elongation Outer jacket aging condition After aging, Tensile strength After aging, Elongation Cold bend
Outer Jacket Insulation Conductor Rip cord
N/A
Secondary overall shield & material
Outer jacket tensile strength
1 2 3 4
4.White/Brown(Stripe) & Brown < 30mm = < 200mm =
Cabling
100 c x 240 hrs < 85% of Unaging = < 50% of Unaging =
Electrical
Nom. mutual capacitance
Characteristics
Pair to ground capacitance unbalance
No Crack (@ -20 c x 4hrs) < 5.6 nF/100m (@1kHz) = < 330 pF/100m =
Nominal velocity of propagation
65%
Max. delay skew
45 ns/100m
Max. conductor DC resistance
93.8
Max. conductor resistance unbalance
5% (@ 20 c )
Min. insulation resistance
5000 M .km
Max. operating voltage - UL
300 V
/km (@ 20 c )
Page 4
Quantum Cat5e PVC Cable, Grey 305m Box, 4Pair 24AWG U/UTP /
Part No.QTM 0625305
Marking
Quantum UTP Cat 5e 4PR 24AWG PVC ISO/IEC 11801 EN50173 VERIFIED 100 OHM ***M
Note: 1.Where" ***" is recycled meter marking in form of 305M down to 1M indicting length left in box, the marking interval is 1m; 2.Marking color shall be black except black jacket with white printing; 3.Marking height:2.8±0.2mm; Marking width:2.0±0.2mm
Electrical characteristics Frequency
Character impedance upper limit
Character impedance lower limit
RL
ATT
NEXTP
S NEXT
dB Min)
(dB/100m)(
dB Min)
(dB Min)
ELFEXTP
S ELFEXTP
(dB Min)
(dB Min)
D
)(
)(
1.8
67.0
64.0—
1
122.2
81.8
20.02
.0
65.3
62.3
63.8
60.8
570.0
4
115.2
86.8
23.04
.1
56.3
53.3
51.7
48.7
552.0
(MHz)( 0.772—
——
(ns/100m Max)
——
8
112.6
88.8
24.5
5.8
51.8
48.8
45.7
42.7
547.0
10
111.9
89.4
25.06
.5
50.3
47.3
43.8
40.8
545.0
16
111.9
89.4
25.08
.2
47.3
44.3
39.7
36.7
543.0
20
111.9
89.4
25.0
9.3
45.8
42.8
37.7
34.7
542.0
25
112.9
88.5
24.3
10.4
44.3
41.3
35.8
32.8
541.0
31.25
114.1
87.7
23.6
11.7
42.9
39.9
33.9
30.9
540.0
62.5
118.3
84.5
21.5
17.0
38.4
35.4
27.8
24.8
539.0
100
121.9
82.0
20.1
22.0
35.3
32.3
23.8
20.8
538.0
Note: Cable that meet the requirements of the template are not required to be measured for return loss; alternately cables that meet the return loss requirements are not required to be measured for characteristic impedance. Wadsworth Code
Delivery Length Weight
Remark
Description
QTM - 0625305
305 m
Unreel box
Quantum Cat5e PVC Cable, Grey
Colour
RAL Code
Gey (PVC)
RAL 7032
10kg
Page 5
Quantum Cat5e LSZH Cable, Orange 4 Pair 24AWG U/UTP / Description
Application 100Base-T4 100Base-TX 100VG-AnyLAN 1000Base-T 1000Base-TX 155Mbps ATM 622Mbps ATM
Rated temperature: 75 c Reference standard: UL444, TIA/EIA-568-B.2 & ISO 11801,IEC61156 Product standard certification: Flame test: IEC 60332-1 Solid bare copper conductor Colour-coded PE insulation LSZH jacket
Product figure
Part No. QTM - 0625306
Physical characteristics Structure Conductor
Insulation
Construction
U/UTP
Number of Pairs
4 Pairs
AWG
24 AWG
Conductor material
Solid bare copper
Conductor dimension
0.505 ±0.02 mm
Insulation material
HDPE
Insulation dimension
0.88 ±0.05 mm
Number colour
1.White/Blue(Stripe) & Blue
(Stripe marking)
2.White/Orange(Stripe)&Orange 3.White/Green(Stripe) & Green
Filler
Filler material
4.White/Brown(Stripe) & Brown < 30mm = < 200mm = N/A
Binder
Binder material
N/A
Shield
Individual shield & material
N/A
Cabling
Twisting lay length Cabling lay length
Outer jacket
Primary overall shield & material
N/A
Secondary overall shield & material
N/A
Shield coverage
N/A
Drain wire
N/A
Outer jacket material
LSZH
Outer jacket thickness ( Nom)
0.5mm
Overall nominal dimension
5.0±0.3 mm
Outer jacket colour
RAL2004
Outer jacket rip cord
Yes
Mechanical
Operating temperature range
-20 c ~ +75 c
characteristics
Bulk cable weight
30 kg/km
Max. recommended pulling tension
110 N
Min. bend radius (install)
4 x O.D. < 8.3MPa = < 100% =
Outer jacket tensile strength Outer jacket elongation Outer jacket aging condition After aging, Tensile strength After aging, Elongation Cold bend
1 2 3 4
Outer Jacket Insulation Conductor Rip cord
100 c x 48hrs < 75% of Unaging = < 75% of Unaging =
Electrical
Nom. mutual capacitance
Characteristics
Pair to ground capacitance unbalance
No Crack (@ -20 c x 4hrs) < 5.6 nF/100m (@1kHz) = < 330 pF/100m =
Nominal velocity of propagation
65%
Max. delay skew
45 ns/100m
Max. conductor DC resistance
93.8
Max. conductor resistance unbalance
5% (@ 20 c )
Min. insulation resistance
5000 M .km
Max. operating voltage - UL
300 V
/km (@ 20 c )
Page 6
Quantum Cat5e LSZH Cable, Orange 4 Pair 24AWG U/UTP /
Part No. QTM - 0625306
Marking
Quantum UTP Cat 5e 4PR 24AWG LSZH ISO/IEC 11801 EN50173 VERIFIED 100 OHM ***M
Note: 1.Where" ***" is recycled meter marking in form of 305M down to 1M indicting length left in box, the marking interval is 1m; 2.Marking color shall be black except black jacket with white printing; 3.Marking height:2.8±0.2mm; Marking width:2.0±0.2mm
Electrical characteristics Character Character Frequency impedance impedance upper limit lower limit (MHz)(
)(
0.772—
)(
RL
ATT
NEXT
dB Min)
(dB/100m)(
dB Min)
——
1.8
67.0
PS NEXT ELFEXTP S ELFEXTP (dB Min)
(dB Min)
64.0—
(dB Min)
D
(ns/100m Max)
——
1
122.2
81.8
20.0
2.0
65.3
62.3
63.8
60.8
570.0
4
115.2
86.8
23.04
.1
56.3
53.3
51.7
48.7
552.0
8
112.6
88.8
24.55
.8
51.8
48.8
45.7
42.7
547.0
10
111.9
89.4
25.06
.5
50.3
47.3
43.8
40.8
545.0
16
111.9
89.4
25.08
.2
47.3
44.3
39.7
36.7
543.0
20
111.9
89.4
25.09
.3
45.8
42.8
37.7
34.7
542.0
25
112.9
88.5
24.3
10.4
44.3
41.3
35.8
32.8
541.0
31.25
114.1
87.7
23.6
11.7
42.9
39.9
33.9
30.9
540.0
62.5
118.3
84.5
21.5
17.0
38.4
35.4
27.8
24.8
539.0
100
121.9
82.0
20.1
22.0
35.3
32.3
23.8
20.8
538.0
Note: Cable that meet the requirements of the template are not required to be measured for return loss; alternately cables that meet the return loss requirements are not required to be measured for characteristic impedance. Wadsworth Code
Delivery Length Weight
Remark
Description
QTM - 0625306OR
305 m
10k g
Unreel box Quantum Cat5e LSZH Cable, Orange
QTM - 0625306VI
305 m
10k g
Unreel box Quantum Cat5e LSZH Cable, Purple
Colour
RAL Code
Orange (LSZH)
RAL 2004
Purple (LSZH)
RAL4005
Page 7
Quantum Cat5e PE External Cable, 4 Pair 24AWG U/UTP / Description
Application 100Base-T4 100Base-TX 100VG-AnyLAN 1000Base-T 1000Base-TX 155Mbps ATM 622Mbps ATM
Rated temperature:75 c Reference standard: UL444, TIA/EIA-568-B.2 & ISO 11801 Product standard certification: Flame test: Solid bare copper conductor Colour-coded PE insulation PE(Resistant UV) jacket
Product figure
Part No.QTM - 5994458
Physical characteristics Structure Conductor
Insulation
Construction
U/UTP
Number of Pairs
4 Pairs
A WG
24 AWG
Conductor material
Solid bare copper
Conductor dimension
0.505 ±0.02 mm
Insulation material
HDPE
Insulation dimension
0.88 ±0.05 mm
Number colour
1.White/Blue(Stripe) & Blue
(Stripe marking)
2.White/Orange(Stripe) & Orange 3.White/Green(Stripe) & Green
Twisting lay length
Filler
Filler material
Binder
Binder material
N/A
Shield
Individual shield & material
N/A
Primary overall shield & material
N/A
Cabling lay length
Outer jacket
N/A
Shield coverage
N/A
Drain wire
N/A
Outer jacket material
PE (Resistant UV
Outer jacket thickness (Nom)
0.5mm
Overall nominal dimension
5.0 ±0.3 mm
Outer jacket colour
BLACK
Outer jacket rip cord
YES
Mechanical
Operating temperature range
-20 c ~ +75 c
characteristics
Bulk cable weight
38 kg/km
Max. recommended pulling tension
110 N
Min. bend radius (install)
4 x O.D. < 9.7 MPa = < 350% =
Outer jacket elongation Outer jacket aging condition After aging, Tensile strength After aging, Elongation Cold bend
Outer Jacket Insulation Conductor Rip cord
N/A
Secondary overall shield & material
Outer jacket tensile strength
1 2 3 4
4.White/Brown(Stripe) & Brown < 30mm = < 200mm =
Cabling
100 c x 48 hrs < 75% of Unaging = < 75% of Unaging =
Electrical
Nom. mutual capacitance
Characteristics
Pair to ground capacitance unbalance
No Crack (@ -20 c x 4hrs) < 5.6 nF/100m (@1kHz) = < 330 pF/100m =
Nominal velocity of propagation
65%
Max. delay skew
45 ns/100m
Max. conductor DC resistance
93.8
Max. conductor resistance unbalance
5% (@ 20 c )
Min. insulation resistance
5000 M .km
Max. operating voltage - UL
300 V
/km (@ 20 c )
Page 8
Quantum Cat5e PE External Cable, 4 Pair 24AWG U/UTP /
Part No.QTM 5994458
Marking
Quantum UTP Cat 5e 4PR 24AWG PE ISO/IEC 11801 EN50173 VERIFIED 100 OHM ***M
Note: 1.Where" ***" is recycled meter marking in form of 305M down to 1M indicting length left in box, the marking interval is 1m; 2.Marking color shall be black except black jacket with white printing; 3.Marking height:2.8±0.2mm; Marking width:2.0±0.2mm
Electrical characteristics Frequency
Character impedance upper limit
Character impedance lower limit
RL
(MHz) (MHz)(
( ))(
( ))(
(dB dB Min)
1.8
67.0
64.0—
1
122.2
81.8
20.02
.0
65.3
4
115.2
86.8
23.04
.1
56.3
0.772—
——
ATT
NEXT
(dB/100m) (dB/100m)( (dB dB Min)
PS NEXT
ELFEXT
PS ELFEXTP
D
(dB Min)
(dB Min)
(dB Min)
62.3
63.8
60.8
570.0
53.3
51.8
48.8
552.0
(ns/100m Max)
——
8
112.6
88.8
24.5
5.8
51.8
48.8
45.7
42.7
546.7
10
111.9
89.4
25.06
.5
50.3
47.3
43.8
40.8
545.4
16
111.9
89.4
25.08
.2
47.3
44.3
39.7
36.7
543.0
20
111.9
89.4
25.0
9.3
45.8
42.8
37.7
34.7
542.0
25
112.9
88.5
24.3
10.4
44.3
41.3
35.8
32.8
541.2
31.25
114.1
87.7
23.6
11.7
42.9
39.9
33.9
30.9
540.4
62.5
118.3
84.5
21.5
17.0
38.4
35.4
27.8
24.8
538.6
100
121.9
82.0
20.1
22.0
35.3
32.3
23.8
20.8
537.6
Note: Cable that meet the requirements of the template are not required to be measured for return loss; alternately cables that meet the return loss requirements are not required to be measured for characteristic impedance.
Wadsworth Code
Delivery Length Weight
QTM - 5994458
305 m
Colour
RAL Code
Black
RAL 9005
10k g
Remark
Description
Unreel box
Quantum Cat5e PE Cable
Page 9
QUANTUM Category 5e RJ45 Module - Euro Size
Features Exceeds Cat 5e performance standards Rear cable tie point Euro & LJ6C modules available LSA Style Termination blocks Low profile one piece snap in design Available Pre Loaded in Bevelled Faceplates Flat or Bevelled Faceplate options
Sturdy Shutter Removable Lable Window Sharpmark Labels
Product Overview The Quantum Cat 5e UTP module provides full channel compliancy as part of a Quantum Cat 5e network. Euro modules provide easy top entry termination, with a clip-on design fitting directly into a Euro 50 x 25mm aperture for easy installation. The low profile design makes the module ideal for installations in floor box environments or shallow containment
Page 10
Detailed Images
Specification 1. Modular & Door : ABS, UL 94-HB 2. Jack, Contact Material & Finished 2.1 Phosphor Bronze with 50-60 micro-inch Nickel plated. 2.2 Contact area : Min 3mm 50 micro-inch Gold Plated. 3. IDC Housing : Polycarbonate, UL 94V-2. 4. IDC Terminal material & finished : 4.1 Phospher Bronze with 50-60 micro-inch nickel plated. 4-2 Krone tool only. 4-3 Use for 22-26 AWG stronded and solid wire 5. Cable Holder : PP, UL 94V-2, Transparence color. 6. Name Plate : Polycarbonate, UL 94V-2, Transparent Color 7. IDC GAP : ABS+PC. UL 94-HB Performance : 1. The sticker color codes combine two winngs of T568A & T568B 2. Insertion force : 900gms for 8 contacts. 3. Retention strength : 7.7 kgs between Jack and Plug 4. Operation temperature : -40 oc to 80 oc. 5. Durability : 6. 6-1 Jack : 750 cycles Plug-Jack mating and unmating test, insertion cycles of 20 cycles/minute max. Contact resistance test per 100 cycles. 6-2 IDC : Max 200 punching times 7. The Cat5e performance is in compliance with the ANSI/TIA/EIA B.2 Stanadard
Performance / Specification Jack life min
800 insertions
IDC contact life up to 50 re-insertions
Yes
Max. of two wires per IDC contact
Yes
Max. diameter of wire including insulation
1.44mm dia.
Wire gauge
22-26 AWG
Channel worst pair crosstalk
200MHz: -39.1dB
Channel return loss better than
15dB @ 200MHz
Tested to ANSI TIA/EIA
568B 2-1
Applications 10BaseT Ethernet 100BaseTX Fast Ethernet 1000BaseTX Fast Ethernet 155 MBit ATM 622 MBit ATM 1.2 Gbit ATM Future Class E applications
Part Numbers Part No.
Description
QTM - 6207000B
Quantum Cat5e RJ45 module Euro
QTM - 7103550/1
1 x Cat5e UTP Module in Single Gang Faceplate - Blanks
QTM - 7103550/2
2 x Cat5e UTP Module in Single Gang Faceplate - Blanks
QTM - 7103550/3
3 x Cat5e UTP Module in Single Gang Faceplate
QTM - 7103550/4
4 x Cat5e UTP Module in Single Gang Faceplate
QTM - 6207110
Quantum Single Gang Faceplate (Euro)
QTM - 6207120
Quantum Double Gang Faceplate (Euro)
QTM - 6207130
Quantum Half Blank (Euro)
QTM - 6207131
Quantum Quarter Blank (Euro)
Page 11
QUANTUM Category 5e RJ45 Module - LJ6C Size
Features Exceeds Cat 5e performance standards Rear cable tie point LSA Style Termination blocks Low profile one piece snap in design Flat Faceplate options Sturdy Shutter Removable Lable Window
Sharpmark Labels
Product Overview The Quantum Cat 5e UTP module provides full channel compliancy as part of a Quantum Cat 5e network. LJ6C modules provide easy top entry termination, with a clip-on design fitting directly into a LJ6C aperture for easy installation. The low profile design makes the module ideal for installations in floor box environments or shallow containment
Page 12
Detailed Images
Specification 1. Modular & Door : ABS, UL 94-HB 2. Jack, Contact Material & Finished 2.1 Phosphor Bronze with 50-60 micro-inch Nickel plated. 2.2 Contact area : Min 3mm 50 micro-inch Gold Plated. 3. IDC Housing : Polycarbonate, UL 94V-2. 4. IDC Terminal material & finished : 4.1 Phospher Bronze with 50-60 micro-inch nickel plated. 4-2 Krone tool only. 4-3 Use for 22-26 AWG stronded and solid wire 5. Cable Holder : PP, UL 94V-2, Transparence color. 6. Name Plate : Polycarbonate, UL 94V-2, Transparent Color 7. IDC GAP : ABS+PC. UL 94-HB Performance : 1. The IDC color codes combine two winngs of T568A & T568B 2. Insertion force : 900gms for 8 contacts. 3. Retention strength : 7.7 kgs between Jack and Plug 4. Operation temperature : -40 oc to 80 oc. 5. Durability : 6. 6-1 Jack : 750 cycles Plug-Jack mating and unmating test, insertion cycles of 20 cycles/minute max. Contact resistance test per 100 cycles. 6-2 IDC : Max 200 punching times 7. The Cat5e performance is in compliance with the ANSI/TIA/EIA B.2 Stanadard
Performance / Specification Jack life min
800 insertions
IDC contact life up to 50 re-insertions
Yes
Max. of two wires per IDC contact
Yes
Max. diameter of wire including insulation
1.44mm dia.
Wire gauge
22-26 AWG
Channel worst pair crosstalk
200MHz: -39.1dB
Channel return loss better than
15dB @ 200MHz
Tested to ANSI TIA/EIA
568B 2-1
Applications 10BaseT Ethernet 100BaseTX Fast Ethernet 1000BaseTX Fast Ethernet 155 MBit ATM 622 MBit ATM 1.2 Gbit ATM Future Class E applications
Part Numbers Part No.
Description
QTM - 6207550
Quantum Cat 5e (LJ6C) RJ45 module
QTM - 6207551
Single gang faceplate 1 x LJ6c
QTM - 6207552
Single gang faceplate 2 x LJ6c
QTM - 6207553
Double gang faceplate 4 x LJ6c
QTM - 6207554
Half blank - LJ6c
QTM - 6207555
Quarter blank - LJ6c
Page 13
Quantum Category 5e Patch Panels Unshielded
Features Independently Delta verified Category 5e compliant IDC Style termination blocks Numerical identification on all ports Optional rear cable management panel Cable tie fixings at rear and cage nuts included
Benefits Guaranteed performance Flexibility to suit installation requirements Low risk choice for IT managers 25 Year System Warranty Low cost/budgetary solution Sharpmark labelling solution Various Labelling options for speed installations
Product Overview Quantum patch panels are independently verified and comply with the current standards for Category 5e. Quantum 5e patch panels are designed to minimize deployment time and maximize connection strength. Each panel offers a choice of labelling systems to include both labelling fields with writeable surface and separate identification strips are provided to allow further labelling where required. A choice of port density of 24 1U or 48 2U ports.
Page 14
Detailed Images
Specification 1. Panel : SPCC, 1.5mm thickness with Black(RAL9005) color pointed 2. RJ45 Jack Housing : ABS, UL 94V-0. 3. RJ45 Jack Contact material & finished : 3-1 Phosphor Bronze with 50-60 micro-inch Nickel Plated. 3-2 Contact Area : Min 3 mm 50 micor-inch Gold Plated. 4. IDC Housing : PC+5%GF, UL 94V 5. IDC Terminal material & finished : 5-1 Phosphar Bronze with 50-60 micor-inch tin plated. 5-2 Compatible with both 110 & Krone punch down tools. 5-3 Suitable for 22-26 AWG stranded & solid wire. 6. Jack Brocket Set: ABS, UL, 94V-0 7. Support Bar : SPCC 1.5mm thickness with black color painted. Performance : 1. The sticker color codes combine two winngs of T568A & T568B 2. Insertion force : 900gms for 8 contacts. 3. Retention strength : 7.7 kgs between Jack and Plug 4. Operation temperature : -40 oc to 80 oc. 5. Durability : 6. 6-1 Jack : 750 cycles Plug-Jack mating and unmating test, insertion cycles of 20 cycles/minute max. Contact resistance test per 100 cycles. 6-2 IDC : Max 200 punching times 7. The Cat5e performance is in compliance with the ANSI/TIA/EIA B.2 Stanadard
Performance / Specification Panel Wiring specification Port density Labeling Insertion Force Retention strength Operating temperature Durability Jack Compatibility
– 1.5mm thickness with black (Ral 9005) colour painted EIA 258A and 568 B.2-1 standard 24 or 48 ports per 1u colour code combines two wiring of T568A & T568B 900gm for 8 contacts 7.7kg between RJ45 port and plug -20c and 70c RJ45 port – 750 cycles plug-jack, IDC max 200 punching times 50 micron gold plated contact pins Suitable for 22-26 AWG stranded and solid wire
Part Numbers Part No. QTM – 6207524 QTM – 62075482U
Description Quantum 24 Port Cat 5e UTP Patch Panel – 1U Quantum 48 Port Cat 5e UTP Patch Panel – 2U
Page 15
Quantum Right Angled Category 5e Patch Panels Unshielded
Features Independently Delta verified Category 5e compliant IDC Style termination blocks Numerical identification on all outlets Cable tie fixings at rear and cage nuts included
Benefits Guaranteed performance Flexibility to suit installation requirements Low risk choice for IT managers 25 Year System Warranty Low cost/budgetary solution Sharpmark labelling solution Right Angled IDC Termination blocks, allows easy vertical termination 1U 48 Port High Density options
Product Overview Quantum patch panels are independently verified and comply with the current standards for Category 5e and are available in a range of installation options. Quantum 5e patch panels are designed to minimize deployment time and maximize connection strength. Each panel offers a choice of labelling systems to include both labelling fields with writeable surface and separate identification strips are provided to allow further labelling where required. A choice of a 1u port density of 24 or 48 ports.
Page 16
Detailed Images
Specification 1. Panel : SPCC, 1.3mm thickness with Black color pointed 2. RJ45 Jack Housing : PBT, UL 94V-0. 3. RJ45 Jack Contact material & finished : 3-1 Phosphor Bronze with 50-60 micro-inch Nickel Plated. 3-2 Contact Area : Min 3mm 50 micor-inch Gold Plated. 4. IDC Housing : PC, UL 94V, Krone Dual 5. IDC Terminal material & finished : 1U 48 Way 5-1 Phosphar Bronze with 50-60 micor-inch tin plated. 5-2 Compatible with both 110 & Krone punch down tools. 5-3 Suitable for 22-26 AWG stranded & solid wire. 6. Jack Brocket Set: ABS, UL, 94V-0 7. Support Bar : SPCC 1.5mm thickness with black color painted. Performance : 1. The sticker color codes combine two winngs of T568A & T568B 2. Insertion force : 900gms for 8 contacts. 3. Retention strength : 7.7 kgs between Jack and Plug 4. Operation temperature : -40 oc to 80 oc. 5. Durability : 6. 6-1 Jack : 750 cycles Plug-Jack mating and unmating test, insertion cycles of 20 cycles/minute max. Contact resistance test per 100 cycles. 6-2 IDC : Max 200 punching times 7. The Cat5e performance is in compliance with the ANSI/TIA/EIA B.2 Stanadard
Performance / Specification Panel
– 1.5mm thickness with black (Ral 9005) colour painted
Wiring specification
EIA 258A and 568 B.2-1 standard
Port density
24 or 48 ports per 1u
Labeling
colour code combines two wiring of T568A & T568B
Insertion Force
900gm for 8 contacts
Retention strength
7.7kg between RJ45 port and plug
Operating temperature
-20c and 70c
Durability
RJ45 port – 750 cycles plug-jack, IDC max 200 punching times
Jack
50 micron gold plated contact pins
Compatibility
Suitable for 22-26 AWG solid wire
Part Numbers Part No.
Description
QTM – 6207548
Quantum 48 port Cat 5e UTP Patch Panel – 1U High Density
QTM – 6207624
Quantum 24 port Cat 5e UTP Patch Panel – Right Angled 1U
Page 17
Quantum Cat6 LSZH Cable, Orange 305m Box, 4 Pair 24AWG U/UTP / Description
Application 100Base-T4 100Base-TX 100VG-AnyLAN 1000Base-T 1000Base-TX 155Mbps ATM 622Mbps ATM
Rated temperature: 75 c Reference standard: UL444, TIA/EIA-568-B & ISO 11801,IEC61156 Product standard certification: Flame test: IEC 60332-1 Solid bare copper conductor Colour-coded PE insulation LSZH jacket
Product figure
Part No. QTM - 0625306
Physical characteristics Structure Conductor
Insulation
Construction
U/UTP
Number of Pairs
4 Pairs
AWG
23 AWG
Conductor material
Solid bare copper
Conductor dimension
0.57 ±0.02 mm
Insulation material
HDPE
Insulation dimension
1.01 ±0.05 mm
Number colour
1.White/Blue(Stripe) & Blue
(Stripe marking)
2.White/Orange(Stripe)&Orange 3.White/Green(Stripe) & Green
Filler
Filler material
4.White/Brown(Stripe) & Brown < 30mm = < 200mm = YES
Binder
Binder material
N/A
Shield
Individual shield & material
N/A
Cabling
Twisting lay length Cabling lay length
Outer jacket
Primary overall shield & material
N/A
Secondary overall shield & material
N/A
Shield coverage
N/A
Drain wire
N/A
Outer jacket material
LSZH
Outer jacket thickness ( Nom)
0.5mm
Overall nominal dimension
6.1 ±/- 0.3 mm
Outer jacket rip cord
Yes
Mechanical
Operating temperature range
-20 c ~ +75 c
characteristics
Bulk cable weight
40 kg/km
Max. recommended pulling tension
110 N
Min. bend radius (install)
4 x O.D. < 8.3MPa = < 100% =
Outer jacket tensile strength Outer jacket elongation Outer jacket aging condition After aging, Tensile strength After aging, Elongation Cold bend
Outer Jacket Insulation Conductor Filler 5 Rip cord 1 2 3 4
Electrical
Nom. mutual capacitance
Characteristics
Pair to ground capacitance unbalance
100 c x 48hrs < 75% of Unaging = < 75% of Unaging =
No Crack (@ -20 c x 4hrs) < 5.6 nF/100m (@1kHz) = < 330 pF/100m =
Nominal velocity of propagation
65%
Max. delay skew
45 ns/100m
Max. conductor DC resistance
73.2
Max. conductor resistance unbalance
5% (@ 20 c )
Min. insulation resistance
5000 M .km
Max. operating voltage - UL
300 V
/km (@ 20 c )
Page 18
Quantum Cat6 LSZH Cable, Orange 305m Box, 4 Pair 24AWG U/UTP Part No. QTM - 0625306 Marking
Quantum UTP Cat 6 4PR 23AWG LSZH ISO/IEC 11801 EN50173 VERIFIED 100 OHM ***M
Reverse marking from 305-0 indicating length of reel
Electrical characteristics Frequency
Character impedance upper limit
RL
/ 115.2 112.6 111.9 111.9 111.9 112.9 114.1 118.3 121.9 128.8
/ 23.0 24.5 25.0 25.0 25.0 24.3 23.6 21.5 20.1 18.0
1 4 8 10 16 20 25 31.25 62.5 100 200
ATT
NEXT
/ 3.8 5.3 6.0 7.6 8.5 9.5 10.7 15.4 19.8 29.0
74.3 65.3 60.8 59.3 56.2 54.8 53.3 51.9 47.4 44.3 39.8
PSNEXT
ELFNEXT
72.3 63.3 58.8 57.3 54.2 52.8 51.3 49.9 45.4 42.3 37.8
67.8 55.8 49.7 47.8 43.7 41.8 39.8 37.9 31.9 27.8 21.8
PS ELFNEXT
64.8 52.8 46.7 44.8 40.7 38.8 36.8 34.9 28.9 24.8 19.8
PD
570 552.0 547.0 545.0 543.0 542.0 541.0 540.0 539.0 538.0 537.0
Character impedance lower limit
/ 86.8 88.8 89.4 89.4 89.4 88.5 87.7 84.5 82.0 77.6
Note: Cable that meet the requirements of the template are not required to be measured for return loss; alternately cables that meet the return loss requirements are not required to be measured for characteristic impedance. Wadsworth Code
Delivery Length Weight
QTM - 0625326OR
305 m8
12 kg ,5
Unreel box Quantum Cat5e LSZH Cable, Orange
QTM - 0625326VI
305 m8
12 kg ,5
Unreel box Quantum Cat5e LSZH Cable, Purple
Colour
RAL Code
Orange (LSZH) Purple (LSZH)
RAL 2004 RAL 4005
Remark
Description
Page 19
QUANTUM Category 6 RJ45 Module - Euro Size
Features Exceeds Cat 6 performance standards Backward compatible to Cat 5e Rear cable tie point Euro & LJ6c modules available LSA Style Termination blocks Low profile one piece snap in design Available Pre Loaded in Bevelled Faceplates Flat or Bevelled Faceplate options
Sturdy Shutter Removeable Lable Window Sharpmark Labelling
Product Overview The Quantum Cat 6 UTP module provides full channel compliancy as part of a Quantum Cat 6 network. Euro modules provide easy top entry termination, with a clip-on design fitting directly into a Euro 50 x 25mm aperture for easy installation. The low profile design makes the module ideal for installations in floor box environments or shallow containment
Page 20
Detailed Images
Specification 1. Modular & Door : ABS, UL 94-HB 2. Jack, Contact Material & Finished 2.1 Phosphor Bronze with 50-60 micro-inch Nickel plated. 2.2 Contact area : Min 3mm 50 micro-inch Gold Plated. 3. IDC Housing : Polycarbonate, UL 94V-2. 4. IDC Terminal material & finished : 4.1 Phospher Bronze with 50-60 micro-inch nickel plated. 4-2 Krone tool only. 4-3 Use for 22-26 AWG stronded and solid wire 5. Cable Holder : PP, UL 94V-HB. 6. Name Plate : Polycarbonate, UL 94V-2, Transparent Color 7. IDC GAP : ABS+PC. UL 94-HB Performance : 1. The sticker color codes combine two winngs of T568A & T568B 2. Insertion force : 900gms for 8 contacts. 3. Retention strength : 7.7 kgs between Jack and Plug 4. Operation temperature : -40 oc to 80 oc. 5. Durability : 6. 6-1 Jack : 750 cycles Plug-Jack mating and unmating test, insertion cycles of 20 cycles/minute max. Contact resistance test per 100 cycles. 6-2 IDC : Max 200 punching times 7. The Cat5e performance is in compliance with the ANSI/TIA/EIA B.2 Stanadard
Performance / Specification Jack life min
800 insertions
IDC contact life up to 50 re-insertions
Yes
Max. of two wires per IDC contact
Yes
Max. diameter of wire including insulation
1.44mm dia.
Wire gauge
22-26 AWG
Channel worst pair crosstalk
200MHz: -39.1dB
Channel return loss better than
15dB @ 200MHz
Tested to ANSI TIA/EIA
568B 2-1
Part Numbers Part No.
Description
QTM - 7103551
Quantum Cat6 RJ45 module
QTM - 7103552/1
1 x Cat6 UTP Module in Single Gang Faceplate - Blanks
QTM - 7103552/2
2 x Cat6 UTP Module in Single Gang Faceplate - Blanks
QTM - 7103552/3
3 x Cat6 UTP Module in Single Gang Faceplate
QTM - 7103552/4
4 x Cat6 UTP Module in Single Gang Faceplate
QTM - 6207110
Quantum Single Gang Faceplate (Euro)
QTM - 6207120
Quantum Double Gang Faceplate (Euro)
QTM - 6207130
Quantum Half Blank (Euro)
QTM - 6207131
Quantum Quarter Blank (Euro)
Applications 10BaseT Ethernet 100BaseTX Fast Ethernet 1000BaseTX Fast Ethernet 155 MBit ATM 622 MBit ATM 1.2 Gbit ATM Future Class E applications
Page 21
QUANTUM Category 6 RJ45 Module - LJ6C Size
Features Exceeds Cat 6 performance standards Backward compatible to Cat 5e Rear cable tie point LSA Style Termination blocks Low profile one piece snap in design Sturdy Shutter Removable Label Window Flat Faceplate options
Sharpmark Labels
Product Overview The Quantum Cat 6 UTP module provides full channel compliancy as part of a Quantum Cat 6 network. LJ6C modules provide easy top entry termination, with a clip-on design fitting directly into a LJ6C 37 x 21mm aperture for easy installation. The low profile design makes the module ideal for installations in floor box environments or shallow containment
Page 22
Detailed Images
Specification 1. Modular & Door : ABS, UL 94-HB 2. Jack, Contact Material & Finished 2.1 Phosphor Bronze with 50-60 micro-inch Nickel plated. 2.2 Contact area : Min 3mm 50 micro-inch Gold Plated. 3. IDC Housing : Polycarbonate, UL 94V-2. 4. IDC Terminal material & finished : 4.1 Phospher Bronze with 50-60 micro-inch nickel plated. 4-2 Krone tool only. 4-3 Use for 22-26 AWG stronded and solid wire 5. Cable Holder : PP, UL 94V-HB. 6. Name Plate : Polycarbonate, UL 94V-2, Transparent Color 7. IDC GAP : ABS+PC. UL 94-HB Performance : 1. The sticker color codes combine two winngs of T568A & T568B 2. Insertion force : 900gms for 8 contacts. 3. Retention strength : 7.7 kgs between Jack and Plug 4. Operation temperature : -40 oc to 80 oc. 5. Durability : 6. 6-1 Jack : 750 cycles Plug-Jack mating and unmating test, insertion cycles of 20 cycles/minute max. Contact resistance test per 100 cycles. 6-2 IDC : Max 200 punching times 7. The Cat5e performance is in compliance with the ANSI/TIA/EIA B.2 Stanadard
Performance / Specification Jack life min
800 insertions
IDC contact life up to 50 re-insertions
Yes
Max. of two wires per IDC contact
Yes
Max. diameter of wire including insulation
1.44mm dia.
Wire gauge
22-26 AWG
Channel worst pair crosstalk
200MHz: -39.1dB
Channel return loss better than
15dB @ 200MHz
Tested to ANSI TIA/EIA
568B 2-1
Part Numbers Part No.
Description
QTM - 6205236
Quantum Cat6 (LJ6C) RJ45 module
QTM - 6207551
Single gang faceplate 1 x LJ6c aperture
QTM - 6207552
Single gang faceplate 2 x LJ6c aperture
QTM - 6207553
Double gang faceplate 4 x LJ6c aperture
QTM - 6207554
Half blank - LJ6c
QTM - 6207555
Quarter blank - LJ6c
Applications 10BaseT Ethernet 100BaseTX Fast Ethernet 1000BaseTX Fast Ethernet 155 MBit ATM 622 MBit ATM 1.2 Gbit ATM Future Class E applications
Page 23
Quantum Category 6 Patch Panels Unshielded
Features Independently Delta verified Category 6 compliant IDC Style termination blocks Numerical identification on all outlets Optional rear cable management panel Backward compatible Cable tie fixings at rear and cage nuts included
Benefits Guaranteed performance Flexibility to suit installation requirements Low risk choice for IT managers 25 Year System Warranty Low cost/budgetary solution Sharpmark labelling solution Various Label Options
Product Overview Quantum patch panels are independently verified and comply with the current standards for Category 6 and are available in a range of installation options. Quantum 6 patch panels are designed to minimize deployment time and maximize connection strength. Each panel offers a choice of labelling systems to include both labelling fields with writeable surface and separate identification strips are provided to allow further labelling where required. Choice of 24 Port (1U) or 48 Port (2U) are available.
Page 24
Detailed Images
Specification 1. Panel : SPCC, 1.5mm thickness with Black(RAL9005) color pointed 2. RJ45 Jack Housing : ABS, UL 94V-0. 3. RJ45 Jack Contact material & finished : 3-1 Phosphor Bronze with 50-60 micro-inch Nickel Plated. 3-2 Contact Area : Min 3 mm 50 micor-inch Gold Plated. 4. IDC Housing : PC+5%GF, UL 94V 5. IDC Terminal material & finished : 5-1 Phosphar Bronze with 50-60 micor-inch tin plated. 5-2 Compatible with both 110 & Krone punch down tools. 5-3 Suitable for 22-26 AWG stranded & solid wire. 6. Jack Brocket Set: ABS, UL, 94V-0 7. Support Bar : SPCC 1.5mm thickness with black color painted. Performance : 1. The sticker color codes combine two winngs of T568A & T568B 2. Insertion force : 900gms for 8 contacts. 3. Retention strength : 7.7 kgs between Jack and Plug 4. Operation temperature : -40 oc to 80 oc. 5. Durability : 6. 6-1 Jack : 750 cycles Plug-Jack mating and unmating test, insertion cycles of 20 cycles/minute max. Contact resistance test per 100 cycles. 6-2 IDC : Max 200 punching times 7. The Cat5e performance is in compliance with the ANSI/TIA/EIA B.2 Stanadard
Performance / Specification Panel
– 1.5mm thickness with black (Ral 9005) colour painted
Wiring specification
EIA 258A and 568 B.2-1 standard
Port density
24 or 48 ports per 1u
Labeling
colour code combines two wiring of T568A & T568B
Insertion Force
900gm for 8 contacts
Retention strength
7.7kg between RJ45 port and plug
Operating temperature
-20c and 70c
Durability
RJ45 port – 750 cycles plug-jack, IDC max 200 punching times
Jack
50 micron gold plated contact pins
Compatibility
Suitable for 22-26 AWG stranded and solid wire
Part Numbers Part No.
Description
QTM – 71035552U
Quantum 19”, 48 Port Cat 6 Patch Panel – 2U
QTM – 7103554
Quantum 19”, 24 Port Cat 6 Patch Panel – 1U
Page 25
Quantum Right Angled Category 6 Patch Panels Unshielded
Features Independently Delta verified Category 6 compliant IDC Style termination blocks Numerical identification on all outlets Backward compatible Cable tie fixings at rear and cage nuts included
Benefits Guaranteed performance Flexibility to suit installation requirements Low risk choice for IT managers 25 Year System Warranty Low cost/budgetary solution Sharpmark labelling solution
Product Overview Quantum patch panels are independently verified and comply with the current standards for Category 6 and are available in a range of installation options. Quantum 6 patch panels are designed to minimize deployment time and maximize connection strength. Each panel offers a choice of labelling systems to include both labelling fields with writeable surface and separate identification strips are provided to allow further labelling where required. A choice of 1U port density of 24 or 48 ports are available.
Page 26
Detailed Images
Specification 1. Panel : SPCC, 1.3mm thickness with Black color pointed 2. RJ45 Jack Housing : PBT, UL 94V-0. 3. RJ45 Jack Contact material & finished : 3-1 Phosphor Bronze with 50-60 micro-inch Nickel Plated. 3-2 Contact Area : Min 3mm 50 micor-inch Gold Plated. 4. IDC Housing : PC, UL 94V, Krone Dual 5. IDC Terminal material & finished : 5-1 Phosphar Bronze with 50-60 micor-inch tin plated. 5-2 Compatible with both 110 & Krone punch down tools. 5-3 Suitable for 22-26 AWG stranded & solid wire. 6. Jack Brocket Set: ABS, UL, 94V-0 7. Support Bar : SPCC 1.5mm thickness with black color painted. Performance : 1. The sticker color codes combine two winngs of T568A & T568B 2. Insertion force : 900gms for 8 contacts. 3. Retention strength : 7.7 kgs between Jack and Plug 4. Operation temperature : -40 oc to 80 oc. 5. Durability : 6. 6-1 Jack : 750 cycles Plug-Jack mating and unmating test, insertion cycles of 20 cycles/minute max. Contact resistance test per 100 cycles. 6-2 IDC : Max 200 punching times 7. The Cat5e performance is in compliance with the ANSI/TIA/EIA B.2 Stanadard
Performance / Specification Panel
– 1.5mm thickness with black (Ral 9005) colour painted
Wiring specification
EIA 258A and 568 B.2-1 standard
Port density
24 or 48 ports per 1u
Labeling
colour code combines two wiring of T568A & T568B
Insertion Force
900gm for 8 contacts
Retention strength
7.7kg between RJ45 port and plug
Operating temperature
-20c and 70c
Durability
RJ45 port – 750 cycles plug-jack, IDC max 200 punching times
Jack
50 micron gold plated contact pins
Compatibility
Suitable for 22-26 AWG stranded and solid wire
Part Numbers Part No.
Description
QTM – 7103555
Quantum 19”, 48 Port Cat 6 Right Angled Patch Panel – 1U
QTM – 7103564
Quantum 19”, 24 Port Cat 6 Right Angled Patch Panel – 1U
Page 27
Quantum Voice Panels
Features 3 Pairs (6 IDC Contacts) IDC Style Termination Blocks Numerical Identifaction on all ports Cable tie fixings at rear and cage nuts included
Benefits Guranteed performance Flexibilty to suit installation requirement Low risk choice for IT Managers 25 Year System Warranty Sharpmark labelling solution Right Angled IDC Temination Blocks, allows easy vertical termination
Product Overview Quantum voice patch panels are independently verified and comply with the current standards, Quantum voice panels are designed to minimize deployment time and maximize connection strength. Each panel offers a choice of labeling systems to include both labeling fields with writeable surface and separate identification strips are provided to allow further labeling where required. A choice of port density of 24 1U or 48 2U ports
Page 28
Detailed Images
Specification 1. Base case : SECC, 1.5mm thickness with Black color painted 2. RJ45 Jack Housing : ABS, UL 94V-0. 3. RJ45 Jack Contact material & finished : 3-1 Phosphor Bronze with 30-40 micro-inch Nickel Plated. 3-2 Contact Area : Min 3mm 6 micor-inch Gold Plated. 4. IDC Housing : PC, UL 94V-2 5. IDC Terminal material & finished : 5-1 Phosphar Bronze with 50 micor-inch tin plated. 5-2 Krone tool only 6. 5-3 Suitable for 22-26 AWG stranded & solid wire. 7. Ground Cable : 18 AWG Wire, green/yellow striped color, length 40cm Performance : 8. Insertion force : 900gms for 8 contacts. 9. Retention strength : 7.7 kgs between Jack and Plug 10. Operation temperature : -40 oc to 80 oc. 11. Durability : 12. 12-1 Jack : 750 cycles Plug-Jack mating and unmating test, insertion cycles of 20 cycles/minute max. Contact resistance test per 100 cycles. 12-2 IDC : Max 200 punching times
Performance / Specification Panel
– 1.5mm thickness with black (Ral 9005) colour painted
Wiring specification
EIA 258A and 568 B.2-1 standard
Port density
24 or 48 ports per 1u
Labeling
colour code combines two wiring of T568A & T568B
Insertion Force
900gm for 8 contacts
Retention strength
7.7kg between RJ45 port and plug
Operating temperature
-20c and 70c
Durability
RJ45 port – 750 cycles plug-jack, IDC max 200 punching times
Jack
50 micron gold plated contact pins
Compatibility
Suitable for 22-26 AWG solid wire
Part Numbers Part No.
Description
QTM - 6207222
Quantum 25 Port Voice ISDN Panel
QTM - 6207224
Quantum 50 Port Voice ISDN Panel
Page 29
AUTHORISED INSTALLER
This is to certify that .............................................................................. Has been appointed by Quantum as an approved Authorised Installer and is authorised to provide the 25 year warranty
.......................................................... Signed on behalf Quantum Networks Dated........................ Valid for 12 months from date of issue
Authorisation Number...........................
Page 30
Page 31