Transcript
Quick Reference Guide Rev. 1.00 Motherboard Layout and Features
Jumpers and Connectors 17
1 12 111
JI2C1/JI2C2: 1-2:ENABLE 2-3:DISABLE
JL1: CHASSIS INTRUSION JOH1-OH
516
JIPMB1
510
I-SATA0
I-SATA1
JSD2 SATA DOM + POWER
USB 5/6
710
JSD1
713
USB 3/4
714
JTPM1
FAN3 JSTBY1
1 44
415
Front Panel Control (JF1)
J
G
I
K
L
C
E. LAN Port 1
I. LAN Port 5
B. USB Port 1
F. LAN Port 4
J. LAN Port 8 (SFP+)
C. USB Port 0
G. LAN Port 3
K. LAN Port 7 (SFP+)
D. LAN Port 2
H. LAN Port 6
L. VGA Port
Default
21
JBR1
BIOS Recovery
Pins 1-2 (Normal)
74
JBT1
CMOS Clear
Open: Normal, Short: Clear CMOS
16, 17
JI2C1, JI2C2
SMB to PCI-E Slots
Pins 2-3 (Disabled)
14
JPB1
BMC Enable (Debug use only)
Pins 1-2 (Enabled)
18
JPG1
VGA Enable
6, 7, 9
JPL1, JPL2, JPL3 (JPL3: TP8F/TP8F)
LAN1, LAN2, LAN3/4/5/6 Enable
40
JPME1
ME Recovery
Pins 1-2 (Normal)
64
JPME2
Manufacturing Mode
Pins 1-2 (Normal)
53
JPTG1
10Gb Ethernet Enable
Pins 1-2 (Enabled)
20
JPS1 (7TP8F/7TP4F only)
SAS 2.0 Enable/Disable
Pins 1-2 (Enabled)
51
JPUSB1
USB Wakeup (For USB0/1)
Pins 1-2 (Enabled)
22
JWD1
Watch Dog Enable
Pins 1-2 (Reset)
Connector
Connectors
LED7
UID Switch LED
Blue: On
Unit Identified
56
LED8
Overheat/PWR Fail/Fan Fail LED
Red: Solid on Blinking
Solid On: Overheat, Blinking: PWR Fail or Fan Fail
Pins 1-2 (Enabled)
57
LEDM1
BMC Heartbeat LED
Green: Blinking
BMC: Normal
Pins 1-2 (Enabled)
67
LEDS1
SAS Heartbeat LED
Green: Blinking Red
SAS Active SAS Error
Description
75
BT1
Onboard Battery
19
COM1
COM1 Header
47,44,43,35,30,29
FAN1 ~ FAN4, FANA-B
CPU/System Cooling Fans
1
IPMI LAN
Dedicated IPMI LAN Port
71,70,28,26,69,62
I-SATA0 ~ I-SATA5
Intel® Serial ATA Ports (I-SATA0, I-SATA1 support SuperDOM, ISATA4 via M.2, I-SATA5 via Mini-PCIE mSATA)
42
I-SGPIO1
Serial Link General Purpose I/O Headers
68
JD1
Speaker/Buzzer (Pins 1-3: Power LED, Pins 4-7: Speaker)
39
JF1
Front Panel Control Header
41
JGP1
General Purpose I/O Header
13
JIPMB1
4-pin External SMbus I2C Header (for an IPMI Card)
23
JL1
Chassis Intrusion Header
65
JLANLED1
LAN3 ~ LAN6 Activity LED Header (7TP8F/TP8F only)
69
JMD1
M.2 PCI-E 3.0 X4 / I-SATA4 Slot
62
JMP1
Mini PCI-E 2.0 X1 / I-SATA5 Slot
63
JNVI2C1
NVMe I2C Header
24
JOH1
Overheat LED Header
45
JPH1
4-pin Power Connector for HDD use (To provide power from the
49
JPI C1
Power Supply SMBus I2C Header
50
JPV1
12V 8-pin DC Power Connector (To provide alternative power for special enclosure when the 24-pin ATX power is not in use.)
48
JPW1
24-pin ATX Main Power connector
72, 73
JSD1, JSD2
SATA DOM (Device On Module) Power Connector Standby Power Header
66
JTGLED1
LAN7 ~ LAN8 Activity LED Header
NIC1 Activity LED
3.3V Stby
37
JTPM1
Trusted Platform Module (TPM)/Port 80 Connector
NIC2 Activity LED
3.3V Stby
3, 4
LAN1/2, LAN3/4
Gigabit Ethernet (RJ45) Ports (LAN1~LAN6) (LAN3 ~ LAN6 on 7TP8F/
UID LED
5, 8
LAN5/6, LAN7/8
TP8F only). 10Gigabit Ethernet (SFP+) Ports (LAN7 ~ LAN8)
3.3V
34, 33, 31, 32
LSAS0 ~ LSAS15
SAS 2.0 Ports (7TP8F/7TP4F only)
52, 54, 55
M2-SRW1 ~ SRW3
M.2 Mounting Screws
59, 58
MP-SRW1 ~ SRW2
60, 61
SLOT6, SLOT7
PWR
Power Button
1
LAN3 ~ LAN6 is available on 7TP8F/TP8F only
Note: Graphics shown in this quick reference guide are for illustration only. Your components may or may not look exactly the same as drawings shown in this guide.
(7TP8F/7TP4F)
CPU Support Intel® Xeon/Pentium D-1500 Family Processor (BGA).
Memory Support The X10SDV Flex ATX Series motherboard supports up to 128GB of DDR4 ECC RDIMM or 64GB of DDR4 ECC/Non-ECC UDIMM. Note: Check the Supermicro website for recommended memory modules.
DIMM Memory Installation When installing memory modules, the DIMM slots should be populated in the following order: DIMMA1, DIMMB1, then DIMMA2, DIMMB2. •
Always use DDR4 DIMM modules of the same size, type and speed. Mixing memory modules of different types and speeds is not allowed. The motherboard will support one DIMM module installed. However, for best memory performance, install DIMM modules in pairs.
Installing DIMM Memory Modules 1. Align the key on the bottom of the DIMM module against the key on the memory slot. Take note of the notches on the side of the DIMM module, and of the locking clips on the socket to avoid causing damage. Module Key
motherboard to onboard HDD devices.) 2
Module Notch
2. Install the DIMM module straight down into the socket until it is securely seated in the socket. The side clips will automatically lock the module into place.
Recommended Population (Balanced) DIMMB1
4GB
4GB
PCI-E 2.0 X1 / I-SATA5 Slot Mounting Screws
4GB
4GB
CPU PCI-E 3.0 X8 Slot
8GB
8GB
8GB
8GB
16GB
16GB
16GB
16GB
32GB
32GB
32GB
32GB
UID
Unit Identifier (UID) Button
2
USB0/1
Back panel USB 3.0 Ports
36
USB2
USB Type-A
27, 25
USB3/4, USB5/6
Front Access USB 2.0 Ports
10
VGA
Back panel VGA Port
Note: Refer to Chapter 1 of the User Manual for detailed information on jumpers, connectors, and LED indicators.
Locking Clip
Socket Key
DIMMA1
11
Status
12
3.3V Stby
2
Color/State
System Power On
HDD LED
Ground
LED Indicators Green: On
SMBus Header
Reset Button
Description Power LED
JSTBY1
Reset
LED LED3
JSMB1
OH/Fan Fail/PWR Fail
Item # 38
46
Ground
A. IPMI LAN
Description
15
15
Power Fail LED
Back Panel I/O
LED Indicators
Jumpers
3.3 V
16
E
416
Note: Item numbers are shown in counterclockwise order
FP PWR LED
B
417
FAN1
1 42
DIMMA1
1 41
DIMMA2
Back Panel I/O Connectors H
JF1: HDD PWR OH PWR RST X FF NIC2 NIC1 LED LED ON
1 43
318
DIMMB2
1 40
DIMMB1
319
317
JGP1
FAN2
1 314 35
JF1
JPME1
1 33
C
FAN4
I-SGPIO1
LED3
JSAS2 L-SAS4-7
FANA
FANB
1 32
F
JPH1
BT1
PRESS FIT
= mounting hole
D
JBT1: CMOS CLEAR
715
1 36
A
418
711
USB 2
PRESS FIT
311
JPW1
DESIGNED IN USA
JD1: 1-3:PWR LED 4-7:SPEAKER
JD1
JSAS4 L-SAS12-15
PRESS FIT
419
REV:1.01
Intel Xeon D-1500 SoC
Jumper
Item #
JPI2C1
X10SDV-TP8F
1
LAN 7/8
JMD1: M.2 PCI-E 3.0 X4 / I-SATA4
JSAS1 L-SAS0-3
310
DIMMA1 DIMMA2 DIMMB1 DIMMB2
JPL1/JPL2: LAN1/ LAN2 1-2:ENABLE 2-3:DISABLE
PRESS FIT
JSAS3 L-SAS8-11
JPV1
512
618 LSI 2116 (-7TP4F/-7TP8F)
511
JPUSB1
C
C
513
IPMI_LAN USB 0/1(3.0)
LAN 1/2
LEDT3
LEDT4
A
JPL1 JPL2
C
A
LEDT1
A
A
C
619
617
I-SATA2
219
LEDT2
JL1
218
i350 AM4 (-7TP8F/ -TP8F)
JPTG1
712
217
LAN 3/4
LAN 5/6
514
JITP1
JWD1
A
LEDS1
M2_SRW2
JPME2
I-SATA3
1 26
C
M2_SRW1
616
JTGLED1
PHY 10GbE CS2447
JPTG1: 10Gb LAN 1-2:ENABLE 2-3:DISABLE
JBR1
614
12
JPL3: LAN3/4/5/6 1-2:ENABLE 2-3:DISABLE
C
615
JLANLED1
JOH1
215
515
LED8
CPU SLOT7 PCI-E 3.0 X8
JPS1
214
612
COM1
11 2 1 23
613
JMP1 PCI-E 2.0 X1 / I-SATA5
1 19 210
VGA
JNVI2C1
JPG1
1 18
UID
LEDM1
611
CPU SLOT6 PCI-E 3.0 X8
JI2C2
1 17
212
60
JI2C1
1 16
519
MP_SRW1
JSMB1
115
517
BMC AST2400
JPB1
114
A
13
JPUSB1:USB0/1 WAKE UP 1-2:ENABLE 2-3:DISABLE
518
MP_SRW2
14
15
PRESS FIT
M2_SRW3
JWD1:WATCH DOG 1-2:RST 2-3:NMI
18
Item #
11
16
JPL3
BAR CODE
JPG1: 1-2:ENABLE 2-3:DISABLE JPS1:SAS 1-2:ENABLE 2-3:DISABLE
1 13
LED7 C
19
110
A
JBR1 1-2:NORMAL 2-3:BIOS RECOVERY
• Manuals: http://www.supermicro.com/support/manuals • Drivers & Utilities: ftp://ftp.supermicro.com/CDR_Images/CDR-X10-UP/ • Safety: http://www.supermicro.com/about/policies/safety_information.cfm
DIMMA2
DIMMB2
Total System Memory
4GB
4GB
16GB
8GB
8GB
16GB
16GB
64GB
32GB
32GB
128GB
8GB 16GB 32GB 32GB 64GB
Note: Refer to Chapter 2 of the User Manual for detailed information on memory support and CPU/ motherboard installation instructions.
MNL-1858-QRG-100
X10SDV Flex ATX Series
Package Contents • One (1) Supermicro Motherboard • Four (4) SATA Cables • Four (4) Mini-SAS HD Cables (7TP8F/7TP4F SKUs) • One (1) I/O Shield • One (1) Quick Reference Guide
your system to work properly, please download appropriate
drivers/images/user's manual from the links below:
© 2016 Supermicro Computer Inc. All rights reserved. Reproduction of this document whether in part or in whole is strictly prohibited without Supermicro's written consent. All Trademarks are property of their respective entities. All information provided is deemed accurate at the time of printing; however, it is not guaranteed.
SUPERMICR
For
Contact Information • Website: www.supermicro.com • General Information:
[email protected] • Technical Support:
[email protected] • Phone: +1 (408) 503-8000, Fax: +1 (408) 503-8008
R