Preview only show first 10 pages with watermark. For full document please download

Quick Start Guide

   EMBED


Share

Transcript

Quick Start Guide ESSG4P-PG2 Series Ethernet Switch Introduction Welcome to KBC Networks’ Quick Start Guide for the ESSG4P-PG2 Ethernet switch. This document provides some quick tips on how to get up and running. For more detailed information, please see the Downloads section below. The ESSG4P-PG2is a self-managed (self-configuring), hardened Ethernet switch which provides four 10/100/1000Base-TX ports and two 1000Base-FX SFP ports. The 10/100/1000Base-TX ports support IEEE 802.3at PoE+ (Power Sourcing Equipment). The switch complies with IEEE 802.3 10Base-T, IEEE802.3u 100Base-TX/FX, IEEE 802.3x, and IEEE802.3at and will provide PoE power to any IEEE802.3at/af compliant network device. The ESSG4P series supports IGMP snooping which makes significant network bandwidth savings and reduces network load. The switch is ideal for integrating networks of devices such as IP cameras and wireless access points between remote locations. Features             Self-managed switch (self-configures) 4 ports: 10/100/1000Base-TX & 2 ports: 1000Base-FX SFP IEEE 802.3at PoE+ on 10/100/1000Base-TX ports (Power Sourcing Equipment) 2048 MAC address 1Mbit buffer memory Supports 9k Bytes Jumbo Frame Supports energy efficient Ethernet IEEE802.3az Supports 10/100/1000Mbps- Full/half-duplex, Auto-negotiation, Auto-MDI/MDIX Supports Light Hardware IGMP V1, V2, V3 - DIP switch selectable Relay output (dry contact, 1A@24Vdc) for power fail alarm - DIP switch selectable -40°~75°C /-40°~167°F operating temperature Wall-mount or DIN rail installation Downloads Full specifications, features and additional information can be found on the relevant product page on the KBC website as well as in the downloads section: http://www.kbcnetworks.com/downloads General Check the product upon receipt for any visible damage which may have been caused during shipping. System Contents ESSG4P-PG2 Qty Description 1 Hardened self-managed 4-port 10/100/1000Base-T + 2-port 1000Base-X SFP Ethernet switch with PoE+/PSE x 1 1 Quick Start Guide Note: A PoE power supply should be purchased separately for this switch. Please contact your local KBC representative for the appropriate part number. QSG-ESSG4P_Series-Rev1603.docx Copyright © KBC Networks Ltd. 2016 www.kbcnetworks.com Physical Deployment This equipment must be installed and operated in accordance with instructions found in this document. Failure to comply with these instructions will invalidate warranty. Physical Description Front Panel Rear Panel (Din-Rail) Rear Panel (Wall-mount) Mounting holes Left Side View Installation SFP Optical Module You can select different SFP modules as required (Please refer to our SFP ordering options for the appropriate module). To insert or remove the SFP: 1. On the front panel, insert the SFP module into the SFP port until it is securely locked. 2. Connect the optical fiber (1/2 core) to the LC connector(s) of the SFP. 3. To remove the SFP module, press down the LC connector lock of the optical fiber to pull out the fiber cable. 4. Pull down the SFP lever and hold its position. Pull out the SFP module from the SFP port. QSG-ESSG4P_Series-Rev1603.docx Copyright © KBC Networks Ltd. 2016 www.kbcnetworks.com DIN Rail Installation & Removal The ESSG4 can be installed onto a DIN rail as follows: Upper part Metal part 1. Put the switch close to the DIN rail track. Lock the upper part of the DIN rail clip on the upper side of the track. Removal: 1. 2. 2. Press the switch until the metal part moves downwards and a ‘click’ sound is heard. 3. Move the metal part back to its original position. The switch should now be securely locked on to the track and the installation is complete. Pull down the metal part, pull out the lower part of the DIN rail clip until it leaves the track. Lift up the upper part of the clip until the switch separate from the track. Wall-mount Installation Mounting Holes 1. Remove the screws to take out the DIN rail clip from the switch. 2. Tighten the screws to fix the wall mount plate and the switch together. 3. Mount the switch on the wall or on a flat surface with 2 screws piercing through the mounting holes to secure it in position. Setup 1. Connect one end of each of the Ethernet cables to its corresponding port on the product. Connect the other end to the network equipment (such as IP cameras, switches or PCs). Insert the SFP and connect the optical fiber cable to its connectors. 2. Connect the product with the power adapter and switch on the product, the PWR indicator should then be ON. If it is not, please check whether the power cable is connected properly and the power supply functions normally. After all cables are connected, the corresponding indicators will be on.. Interface Pin Signal Name 1 TP0+ & DC+ 2 TP0- & DC+ 3 TP1+ & DC- 4 TP2+ 5 TP2- 6 TP1- & DC- 7 TP3+ 8 TP3- Power & Alarm Connections Pin Desc Power Input V1 - V1 + ALM V2 - V2 + GND +48~57Vdc Normally open GND +48~57Vdc Cable Connections Signal Type Cable Type Connector Ethernet Cat. 5 or above RJ45 Optical SM / MM optical fiber (depends on SFP) LC Power Supply 1 Power cable 6-pin terminal block (pin 1/2) Power Supply 2 TP2+ 6-pin terminal block (pin 5/6) ALM TP2- 6-pin terminal block (pin 3/4) Ports P1-P4 Ethernet ports SFP1, SFP2 Fiber port Power Input 48Vdc (double power input) Dip Switch ALM IGMP On Enable power failure alarm (default setting) Off Disable power failure alarm On Enable IGMP Snooping (default setting) Off Disable IGMP Snooping QSG-ESSG4P_Series-Rev1603.docx Copyright © KBC Networks Ltd. 2016 www.kbcnetworks.com LED Indicators Indicator Colour Status Description PW1 Green On Powered on PW2 Green On Powered on ALM Power cable On Alarm contact closed when either of the power supplies is off SFP 1,2 Green On Fiber link is up Off Fiber is not connected or link is down IGMP Green On IGMP Snooping enabled Off IGMP Snooping disabled On (green) PoE activated Blinking No device is connected or connected device is not PD Off No device is connected On A network device is connected Blinking Connected device is transmitting or receiving data off No network device connected PoE Crystal RJ45 Port (P1 – P4) Link / Act Green Dimensional Drawings Note: All units are in mm DIN Rail Wall-mount panel Compliance FCC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:  This device may not cause harmful interference, and  This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Industry Canada This Class A digital apparatus complies with Canadian ICES-003. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (E.I.R.P.) is not more than that permitted for successful communication. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:  This device may not cause interference, and  This device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil numérique de la classe A est confrome à la norme NMB-003 Canada. Pour réduire le risque d’interférence aux autres utilisateurs, le type d’antenne et son gain doivent être choisies de façon que la puissance isotrope rayonnée équivalente (PIRE) ne dépasse pas ce qui est nécessaire pour une communication réussie. Cet appareil est conforme à la norme RSS Industrie Canada exempts de licence norme(s). Son fonctionnement est soumis aux deux conditions suivantes: 17 Compliance  Cet appareil ne peut pas provoquer d’interférences et  Cet appareil doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif. CE Marking CE marking on this product represents the product is in compliance with all directives that are applicable to it. This equipment may be operated in the following countries: Great Britain and Northern Ireland, Austria, Belgium, Denmark, Finland, France, Germany, Ireland, Italy, Netherlands, Norway, Portugal, Romania, Switzerland, Sweden Installer Compliance Responsibility Devices must be professionally installed and it is the professional installer's responsibility to make sure the device is operated within local country regulatory requirements. RoHS/WEEE Compliance Statement European Directive 2002/96/EC requires that the equipment bearing this symbol on the product and/or its packaging must not be disposed of with unsorted municipal waste. The symbol indicates that this product should be disposed of separately from regular household waste streams. It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences to the environment and human health. For more detailed information about the disposal of your old equipment, please contact your local authorities, waste disposal service, or the shop where you purchased the product. QSG-ESSG4P_Series-Rev1603.docx Copyright © KBC Networks Ltd. 2016 www.kbcnetworks.com Need Help? Please visit our website http://www.kbcnetworks.com or contact your nearest KBC office or dealer: USA Phone: Toll Free: Email: +1 949 297 4930 +1 888 366 4276 [email protected] EMEA Phone: Email: +44(0)1622 618787 [email protected] APAC Phone: Email: +65 98463323 [email protected]