Quick Start Guide
Office Connect 600
Basic Installation Procedure For Up to 20 users on a single electrical phase*
Unpack Car ton Contents
Connect other AV200 Powerline Adapters
Advanced Installation
Basic Installation
1. Carefully unpack all of the components from the carton. 2. The package contents should include: (1) MDU Gateway (10) AV200 Powerline Ethernet Adapters (3) USB cables (1) MDU Gateway power cord (11) RJ45 Ethernet cables (3) Powerline signal coupling cables (3) Powerline to Coax couplers (1) 11+1 coupler (1) Powerline signal coupling cable B (3) Powerline signal loop cables (4) 1m coax cables (6) Inductive couplers (1) RF splitter
CXP-OC600
8. Repeat step 6 and 7 above for up to 9 other computers. The computer will automatically obtain an IP address from the router. Open a web browser. If the Internet is not available, or if an enhanced configuration is required, proceed to step 9.
RJ45 Ethernet cables
O p t i o n a l : Co n f i r m y o u r Co n n e c t i o n 9. Connect your PC directly to the MDU Gateway or to a router/switch that is connected to the MDU Gateway
Powerline signal coupling cable
10. Set the IP address of your computer statically via the following procedure:
CXZ-CXP-CXC
a) From the Start menu open the Control Panel. b) Open Network Connections and right click on Local Area Connection and select Properties. c) Select Internet protocol (TCP/IP) (make sure you don't remove the check mark accidentally) and press the Properties button. d) Select Use the following IP address and enter 10.10.1. 225 set Subnet mask to 255.255.255.0 then press OK.
Powerline to Coax coupler CXZ-CXP-PH12
CXP-MDU-GWY
11+1 coupler
MDU Gateway Powerline signal coupling cable B CXP-AV200-ETHe
AV200 Powerline Ethernet Adapter - Enterprise
Powerline signal loop cable
USB cable
d
1 m coax cable
11. Open a telnet session and check the connection via the following procedure: Inductive coupler
MDU Gateway power cord
a) Insert the Corinex CD and double click on Corinex Telnet to open up a telnet session b) When the program starts press OK to connect to the first module of the MDU Gateway. By default the IP address of the first module is 10.10.1.1
RF splitter
Connect the MDU Gateway 1. Install 3 USB cables into the MDU Gateway. 2. Connect the MDU Gateway power cord to the MDU Gateway and to an electrical outlet. 3. Connect the RJ45 Ethernet cable to an Internet router and to the MDU Gateway. 4. Connect the Powerline signal coupling cable to the MDU Gateway module 1 (or any of the modules, but only one) and to an electrical outlet. 5. Turn On the MDU Gateway
b
2
1
c) After the telnet session starts you can type āiā to get information about the MDU Gateway unit, and the AV200 Powerline Ethernet Adapters. Make sure the number of adapters that you have connected match this list. After an adapter is rebooted it takes up to 1 minute for it to connect to the MDU Gateway. d) You can also telnet to one of the adapters by typing its IP address. Note that you can also check the transmit and receive speeds of the devices using this method.
10.10.1.1 Module 1
3
4
Connect the AV200 Powerline Adapters 6. Connect the power cable to an electrical outlet and to the AV200 Powerline Ethernet Adapter. 7. Connect the RJ45 Ethernet cable to the AV200 Powerline Ethernet Adapter and to a computer.
c
d 1
2
For a detailed list of advanced commands and configurations please check the advanced installation procedure or the Enterprise Software Manual.
* For greater than 20 users or for utilizing more than one module on the MDU Gateway, please see the Corinex Professional MDU Networking Installation and User Manual
Quick Start Guide
Office Connect 600
Advanced Installation Procedure For up to 20 users on multiple electrical phases*
Unpack Car ton Contents
a)Powerline to Coax coupling
Advanced Installation
Basic Installation
1. Carefully unpack all of the components from the carton. 2. The package contents should include: (1) MDU Gateway (10) AV200 Powerline Ethernet Adapters (3) USB cables (1) MDU Gateway power cord (11) RJ45 Ethernet cables (3) Powerline signal coupling cables (3) Powerline to Coax couplers (1) 11+1 coupler (1) Powerline signal coupling cable B (3) Powerline signal loop cables (4) 1m coax cables (6) Inductive couplers (1) RF splitter
CXP-OC600
RJ45 Ethernet cables
Powerline signal coupling cable
1. Connect the 1m coax cable to module 1 (or any of the modules, but only one) of the MDU Gateway, connect to the RF splitter input. 2. Connect the 3 other 1m coax cables to the 3 outputs of the RF splitter. 3. Connect the 3 Powerline to Coax couplers to the 3 coax cables. 4. Connect 3 Powerline signal coupling cables to the 3 Powerline to Coax Couplers. 5. Connect each of the 3 powerline signal coupling cables to each electrical phase (1 outlet for each phase). 6. Continue with the Basic Installation Procedure from step number 6.
CXZ-CXP-CXC
4
Powerline to Coax coupler CXZ-CXP-PH12
5
CXP-MDU-GWY
4
3
11+1 coupler
2
MDU Gateway
5
Powerline signal coupling cable B
4
CXP-AV200-ETHe
Breaker Panel
AV200 Powerline Ethernet Adapter
Powerline signal loop cable
1 5
b)Inductive coupling
1 m coax cable
Inductive coupler
MDU Gateway power cord
1. Connect the Powerline signal coupling cable B to the MDU Gateway module 1 (or any of the modules, but only one) power outlet. 2. Connect each of the 3 powerline signal loop cables to each electrical phase (1 outlet for each phase). 3. Continue with the Basic Installation Procedure from step number 6.
RF splitter
Connect the MDU Gateway (3-Phase Power)
2
1. Install 3 USB cables into the MDU Gateway. 2. Connect the MDU Gateway power cord to the MDU Gateway and to an electrical outlet. 3. Connect the RJ45 Ethernet cable to an Internet router and to the MDU Gateway.
2 10.10.1.1 Module 1
MDU Gateway
2
Breaker Panel
1
Electric Outlet
2
1
MDU Gateway
3
Electric Outlet
USB cable
10.10.1.1 Module 1
3
c)Capacitive coupling
3 4. Ensure each electrical phase is connected to an electrical outlet near the MDU Gateway. If the outlets are not available, an electrician must install them. There are 3 methods for MDU Gateway signal coupling, use only one of these methods: a) Powerline to Coax coupling b) Inductive coupling c) Capacitive coupling
1. Connect the 1m coax cable to module 1 (or any of the modules, but only one) of the MDU Gateway, connect to the 11+1 Coupler input. 2. Connect 3 Powerline signal coupling cables to the 11+1 Coupler. 3. Connect each of the 3 powerline signal coupling cables to each electrical phase (1 outlet for each phase). 4. Continue with the Basic Installation Procedure from step number 6.
3 2 3
Note: The electrician may connect the powerline signal coupling cables directly to the breaker panel to avoid installing the 3 electrical outlets.
Breaker Panel
Electric Outlet
4
2 Breaker Panel
3 1
MDU Gateway
2 Electric Outlet
* For greater than 20 users or for utilizing more than one module on the MDU Gateway please see the Corinex Professional MDU Networking Installation and User Manual