Preview only show first 10 pages with watermark. For full document please download

Quick Start Guide - Avid Technologies, Inc.

   EMBED


Share

Transcript

POWER LED: SYSTEM MONITORING: Wireless power present (Solid) Wireless power removed (OFF) VBRIDGE: Rectified Voltage Basic...…………..9V – 10V (typ.) Extended……. 16V – 18V (typ.) STATUS LED: COMM: Output power enabled, External load detected, Internal load disabled (Amber Solid) VOUT: Basic……9V – 10V, unregulated Extended 12V, 1.25A max Test complete. Expecting Tx to end power transfer (Red Solid) Over temperature (Red Single Blink Pattern) Output overload (Red Double Blink Pattern) CONFIGURATION SWITCHES: (See reverse for all settings) TEST Switch 1, Position 1-6 Selects functional tests Input over voltage (Red Triple Blink Pattern) LOAD Switch 2, Position 1-4 Selects internal load 0-2W, in 0.25W Steps COMM Switch 2, Position 5-6 Selects modulator type TEST and COMM. settings are latched in only at power-up. LOAD setting can be changed during run time. For the latest product documentation and Qi tools discussion please visit: http://www.avid-tech.com/forum TEST Switch Settings LOAD Switch Settings 0000 0-8 1000 9 - 15 0 00 Capacitive AC modulator 1 01 Resistive AC modulator 2 10 Resistive DC modulator 3 11 Reserved 25 Sends invalid WPC spec. version (v0.1) Sends a reserved packet in 010101 Config. Phase Sends reserved packets in 010110 Power Transfer Phase Requests invalid Power Ctrl. 010111 Hold-off Time (210ms) End Power Transfer (EPT) First message sent is 011000 EPT: Charged 011001 EPT: Battery Fault (0x06)* 26 011010 EPT: Charged (0x01)* 27 011011 EPT: Internal Fault (0x02)* 28 011100 EPT: No Response (0x08)* 29 011101 30 011110 31 011111 32 100000 33 100001 EPT: Over Current (0x05)* EPT: Over Temperature (0x03)* EPT: Over Voltage (0x04)* EPT: Reconfigure (0x09, Reserved in v1.2)* EPT: Unknown (0x00)* 20 1 000001 Comm. data bit rate (-30 %) 22 2 000010 Comm. data bit rate (-10 %) 3 000011 Comm. data bit rate (-4 %) 4 000100 Comm. data bit rate (+4 %) 5 6 000101 000110 7 8 9 10 11 12 13 14 15 16 17 010001 18 010010 19 010011 ID Message not sent Sends Power Ctrl. Holdoff Msg. after Config. Msg. Sends maximum optional messages in Config. Phase [email protected] www.avid-tech.com © 2016 AVID Technologies, Inc. All rights reserved. 99000174 Rev.A 21 Comm. data bit rate (+10 %) Comm. data bit rate (+30 %) Packet Timing Invalid time between 000111 messages in Config. Phase 001000 Sends 1st CEP late 001001 Sends 2nd CEP late 001010 Sends CEP at min. intervals Requests 50ms Power Ctrl. 001011 Hold-off Time Packet Data / Order 001100 Sends no comm. packets Sends no Rectified Power 001101 Packets Sends invalid checksum in all 001110 messages Sends invalid checksum in ID 001111 Message only Sends proprietary packet first 010000 instead of Signal Strength Sets Internal Load, 0.0W – 2.0W in 0.25W Steps Reserved (0.00W) COMM Switch Settings Default WPC Receiver (min. 000000 messages in Config. Phase) Comm. Data Bit Rate 0 Quick Start Guide Output enabled (Green Solid) Modulation Signal (0-3.3V Logic) 23 24 34 010100 100010 Misc. Tests Sends only negative error packets Negotiation 35 100011 Neg. Phase Disabled 36 100100 No FOD Status Packet 37 100101 High-Q FOD Status Packet 38 100110 Low-Q FOD Status Packet 39 100111 40 101000 Send FOD Status Packet late Requests Modulation Depth change twice 41 101001 FSK Request Max, Negative 42 101010 FSK Request Min, Negative 43 101011 FSK Request Min, Positive 44 101100 FSK Request Max, Positive 45 101101 5W Max, 10W Guaranteed 46 101110 15W Max, 31.5W Guaranteed 47 101111 48 110000 49 110001 50 110010 51 110011 52 110100 Invalid checksum in Max Pwr Send all valid packet types in Negotiation Phase Sends Reserved Packet in Negotiation Phase End Negotiation with Incorrect Parameter Count End with Negotiation Failure EPT (0x0A) End Negotiation with CEP FOD Calibration and Power Transfer 53 110101 No FOD Calibration Phase Uses high resolution power 54 110110 packet without requesting it Communicates during Tx 55 110111 response time 56 111000 Increase VBRIDGE by 2V 57 111001 Decrease VBRIDGE by 2V 58 111010 59 111011 60 111100 DECREASE VBRIDGE by 4V Use Extended Power Profile regardless of Tx capability EPT: Restart Power Transfer (0x0B)* Reserved: No communication 61 - 63 * Message sent 2 sec. after power transfer starts.