Transcript
POWER LED:
SYSTEM MONITORING:
Wireless power present (Solid) Wireless power removed (OFF)
VBRIDGE: Rectified Voltage Basic...…………..9V – 10V (typ.) Extended……. 16V – 18V (typ.)
STATUS LED:
COMM:
Output power enabled, External load detected, Internal load disabled (Amber Solid)
VOUT: Basic……9V – 10V, unregulated Extended 12V, 1.25A max
Test complete. Expecting Tx to end power transfer (Red Solid) Over temperature (Red Single Blink Pattern) Output overload (Red Double Blink Pattern)
CONFIGURATION SWITCHES: (See reverse for all settings) TEST Switch 1, Position 1-6 Selects functional tests
Input over voltage (Red Triple Blink Pattern)
LOAD Switch 2, Position 1-4 Selects internal load 0-2W, in 0.25W Steps COMM Switch 2, Position 5-6 Selects modulator type TEST and COMM. settings are latched in only at power-up. LOAD setting can be changed during run time. For the latest product documentation and Qi tools discussion please visit: http://www.avid-tech.com/forum
TEST Switch Settings
LOAD Switch Settings 0000 0-8 1000 9 - 15
0
00
Capacitive AC modulator
1
01
Resistive AC modulator
2
10
Resistive DC modulator
3
11
Reserved
25
Sends invalid WPC spec. version (v0.1) Sends a reserved packet in 010101 Config. Phase Sends reserved packets in 010110 Power Transfer Phase Requests invalid Power Ctrl. 010111 Hold-off Time (210ms) End Power Transfer (EPT) First message sent is 011000 EPT: Charged 011001 EPT: Battery Fault (0x06)*
26
011010
EPT: Charged (0x01)*
27
011011
EPT: Internal Fault (0x02)*
28
011100
EPT: No Response (0x08)*
29
011101
30
011110
31
011111
32
100000
33
100001
EPT: Over Current (0x05)* EPT: Over Temperature (0x03)* EPT: Over Voltage (0x04)* EPT: Reconfigure (0x09, Reserved in v1.2)* EPT: Unknown (0x00)*
20
1
000001
Comm. data bit rate (-30 %)
22
2
000010
Comm. data bit rate (-10 %)
3
000011
Comm. data bit rate (-4 %)
4
000100
Comm. data bit rate (+4 %)
5 6
000101 000110
7 8 9 10 11 12 13 14 15 16 17
010001
18
010010
19
010011
ID Message not sent Sends Power Ctrl. Holdoff Msg. after Config. Msg. Sends maximum optional messages in Config. Phase
[email protected] www.avid-tech.com © 2016 AVID Technologies, Inc. All rights reserved. 99000174 Rev.A
21
Comm. data bit rate (+10 %) Comm. data bit rate (+30 %) Packet Timing Invalid time between 000111 messages in Config. Phase 001000 Sends 1st CEP late 001001 Sends 2nd CEP late 001010 Sends CEP at min. intervals Requests 50ms Power Ctrl. 001011 Hold-off Time Packet Data / Order 001100 Sends no comm. packets Sends no Rectified Power 001101 Packets Sends invalid checksum in all 001110 messages Sends invalid checksum in ID 001111 Message only Sends proprietary packet first 010000 instead of Signal Strength
Sets Internal Load, 0.0W – 2.0W in 0.25W Steps Reserved (0.00W)
COMM Switch Settings
Default WPC Receiver (min. 000000 messages in Config. Phase) Comm. Data Bit Rate
0
Quick Start Guide
Output enabled (Green Solid)
Modulation Signal (0-3.3V Logic)
23
24
34
010100
100010
Misc. Tests Sends only negative error packets Negotiation
35
100011
Neg. Phase Disabled
36
100100
No FOD Status Packet
37
100101
High-Q FOD Status Packet
38
100110
Low-Q FOD Status Packet
39
100111
40
101000
Send FOD Status Packet late Requests Modulation Depth change twice
41
101001
FSK Request Max, Negative
42
101010
FSK Request Min, Negative
43
101011
FSK Request Min, Positive
44
101100
FSK Request Max, Positive
45
101101
5W Max, 10W Guaranteed
46
101110
15W Max, 31.5W Guaranteed
47
101111
48
110000
49
110001
50
110010
51
110011
52
110100
Invalid checksum in Max Pwr Send all valid packet types in Negotiation Phase Sends Reserved Packet in Negotiation Phase End Negotiation with Incorrect Parameter Count End with Negotiation Failure EPT (0x0A) End Negotiation with CEP
FOD Calibration and Power Transfer 53 110101 No FOD Calibration Phase Uses high resolution power 54 110110 packet without requesting it Communicates during Tx 55 110111 response time 56 111000 Increase VBRIDGE by 2V 57
111001
Decrease VBRIDGE by 2V
58
111010
59
111011
60
111100
DECREASE VBRIDGE by 4V Use Extended Power Profile regardless of Tx capability EPT: Restart Power Transfer (0x0B)* Reserved: No communication
61 - 63
* Message sent 2 sec. after power transfer starts.