Quick Start Guide Ccd4a-2220-eu

   EMBED


Share

Transcript

Quick start guide CCD4A-2220-EU Care Call Care Call Mini Magnetic Door Monitor Any questions? Call us on +353 (0)1 247 9007 Magnetic Activation 1. Screw cap Status light Magnet Test button PUSH CCM3A-2216-EU-PIR-MKX MOVEMENT MONITOR 11/12/13 USE MAINS POWER SUPPLY PS3A-2207-UK ONLY SILENT ALERT SA3000 SYSTEM WWW.SILENTALERT.IE Silent Alert International TEL +353 (0)1 247 9007 CCD4A-2220-EU CARE CALL MINI MAGNETIC DOOR MONITOR USE ALKALINE PP3 9 V BATTERY ONLY Batch 06/01/14 www.silentalert.ie Silent Alert International, IRL Tel: +353 (0)1 247 9007 Configuration switch Cover 12345678 2. PP3 Battery Keys 1-4 System Channel Key 5=10 Sec Delay Key 6=20 Sec Delay Keys 5+6=30 Sec Delay Key 7 Leave ON Key 8 Not Used USE WITH MAGNET SUPPLIED USE WITH MAGNET SUPPLIED 9 10 11 12 13 14 15 16 MOVE KEY DOWN TO SWITCH ON PUSH 1 2 3 4 5 6 7 8 Configuration switches shown with cover removed. Do not alter these without referring to page 2 The monitor is activated using an internal reed switch and a magnet. To test the unit press the button on the front of the unit. Test Button Magnetic switch pickup area Alternatively the supplied magnet can be used to trigger the unit by swiping it through the pickup area. PUSH PUSH When a battery is first fitted the indicator light will flash red then green a few times then light solid green & pause briefly. The light will then will flash green several times to show the battery voltage. 9 flashes = 9Volts in the battery. 1 = System Code 1 2= System Code 2 3 = System Code 3 4 = System Code 4 5 = Audio Monitoring 6 = Zone Multiplier (7-12) 7 = Short Audio Delay 8 = Medium Audio Delay 7 & 8 = Long Audio Delay 9 = PIR Delay 5 Mins 10 = PIR Delay 10 Mins 9 & 10 = PIR Delay 15 mins 11 = Zone 6 12 = Zone 5 13 = Zone 4 14 = Zone 3 15 = Zone 2 16 = Zone 1 Screw cap CCD4A-2220-EU CARE CALL MINI MAGNETIC DOOR MONITOR USE ALKALINE PP3 9 V BATTERY ONLY Batch 06/01/14 www.silentalert.ie Silent Alert International, IRL Tel: +353 (0)1 247 9007 Keys 1-4 System Channel Key 5=10 Sec Delay Key 6=20 Sec Delay Keys 5+6=30 Sec Delay Key 7 Leave ON Key 8 Not Used PP3 battery contacts PUSH Install a 9 volt PP3 alkaline or lithium battery making sure to observe the correct polarity. PUSH If the light flashes red at this point the battery is flat and will need to be replaced. To repeat the battery check remove the battery, press the test button then re-insert the battery to start the sequence again. 3. Secure the Mini Monitor to the door frame as close as possible to the edge of the door using the supplied screws. The Magnet must pass within 1cm of the pickup area to trigger the unit. NOTE* The magnet must pass within 1cm of the pickup area to activate the unit. We recommend mounting the monitor opposite to the door hinge. The magnet does not need to be in close proximity to the pickup area when the door is closed as the unit is triggered when the magnet passes through the pickup area. PUSH PUSH 4. PUSH The magnet needs to pass within 1cm of the pickup area as the door is opened. It is possible to mount the monitor in a variety of positions as shown in the diagram. Experiment to find the best position before fixing to the door frame. Once the optimum position has been established the magnet should be secured to the door frame using the sticky pad or screws provided. Deactivating & reactivating the door monitor MOVE KEY DOWN TO SWITCH ON Press and hold the test button until the light flashes red, then release. This will deactivate the door sensor. PUSH PUSH Press and hold the test button until the light flashes green, then release. This will reactivate the door sensor. Advanced settings CCD4A-2220-EU Care Call Care Call Mini Magnetic Door Monitor Any questions? Call us on +353 (0)1 247 9007 Changing the Zone The unit will by default cause zone 1 on the pager or signwave to light. 2. 1. 3. To change the zone you need to reset the monitor: Remove the battery, press the push button, replace the battery. PUSH CCM3A-2216-EU-PIR-MKX MOVEMENT MONITOR 11/12/13 USE MAINS POWER SUPPLY PS3A-2207-UK ONLY SILENT ALERT SA3000 SYSTEM After the flashing red/ green startup sequence the light will shine constant green. Press and release the button whilst the light is green. The light will flash red once, twice then three times and so on up to twelve. PUSH WWW.SILENTALERT.IE Silent Alert International TEL +353 (0)1 247 9007 PUSH To set the zone number, briefly press the test button at the desired number of flashes. The indicator light will flash green to confirm the selection. 5. MOVE KEY DOWN TO SWITCH ON 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 = System Code 1 2= System Code 2 3 = System Code 3 4 = System Code 4 5 = Audio Monitoring 6 = Zone Multiplier (7-12) 7 = Short Audio Delay 8 = Medium Audio Delay 7 & 8 = Long Audio Delay 9 = PIR Delay 5 Mins 10 = PIR Delay 10 Mins 9 & 10 = PIR Delay 15 mins 11 = Zone 6 12 = Zone 5 13 = Zone 4 14 = Zone 3 15 = Zone 2 16 = Zone 1 4. PUSH The monitor will then perform the battery voltage level display and start as normal. Press the test button to confirm the correct zone has been selected. Setting trigger delays It is possible to set trigger delays allowing a set amount of time to pass for the user to clear the door before the monitor will transmit. 2. 1. 20 seconds 10 seconds 30 seconds 12345678 12345678 PUSH To activate the trigger delay move key 5 to the on position. The delay can be increased if required. 12345678 12345678 Remove the control key cover by with a small flat bladed screwdriver. Key 7 will already be set. This must NOT be switched off. 3. Now when the door is opened the monitor will flash red for 10 seconds. If the door doesn't shut within this time the monitor will transmit. Changing the system channel code NOTE. In most cases it is not necessary to change the system code. However, when one or more systems are in close proximity, system codes can be used to avoid interference from other Care Call systems using up to a maximum of 16 channels. 15 14 16 12345678 12345678 12345678 12345678 12345678 12345678 12345678 MOVE KEY DOWN TO SWITCH ON 8 12345678 13 12 7 12345678 11 6 12345678 12345678 10 5 4 12345678 12345678 12345678 Be sure that the same system code is set on the receiver to be used and any other monitoring options in that system. 9 12345678 System codes can be set using key switches 1 - 4. The diagram to the right shows the 16 possible combinations. 3 2 1 12345678 The monitor is supplied with no system code switches set (system code 1). For reference this is the factory setting should you need to re-set the unit.