ELECTROMAGNETIC LOCK INSTALLATION OVERVIEW PLEASE READ BEFORE INSTALLATING Familiarize yourself with the gate and post conditions prior to installation. The lock must rigidly mount to the gate post. The armature is designed to pivot slightly to compensate for reasonable misalignment. Due to the wide diversity of gate designs custom mounting brackets may be necessary to facilitate the installation. An L-Z Bracket is included to accomodate the majority of gate applications. The lock is mounted to the vertical gate post. The armature is mounted to the leading edge of the gate.
PARTS & HARDWARE HARDWARE PACK 1
HARDWARE PACK 2
GTO Sales: (800) 543-GATE (4283) or (850) 575-0176 • Fax (850) 575-8912 or GTO Technical Service (800) 543-1236 or (850) 575-4144 For 24 hour/day, 7 day/week Technical Service visit http://support.gtoinc.com/support/troubleshooter.aspx 2008 GTO, Inc.
©
rev- 08/25/08
SURVEY THE INSTALLATION Inspect the gate and determine if supplemental brackets and/or special mounting hardware will be required for installation. If you are using the L-Z Bracket refer to the instructions furnished for specific installation information. Fabricate/procure custom bracket(s), hardware, and/or attachments as necessary. PREPARE THE GATE POST FOR MOUNTING THE GATE LOCK ASSEMBLY Determine the desired location for mounting the Gate Lock assembly on the gate post. If you are mounting the lock assembly directly to the post, locate, mark, and drill four mounting screw holes. If using an intermediate bracket to affix the lock assembly to the post, prep the mounting screw holes accordingly. PREPARE THE GATE FOR ARMATURE MOUNTING If the L-Z bracket will be used to affix the armature to the gate, prep the amature mounting and antispin pin holes on the bracket accordingly. L-Z BRACKET ASSEMBLY
SLIDE GATE APPLICATION EXAMPLE
SWING GATE APPLICATION EXAMPLE
1
MOUNTING THE ARMATURE Locate the two 3/16” dia. anti-spin pins from the hardware kit. Place the armature face-down on a soft surface and drive the anti-spin pins into the holes provided. Refer to the illustrations below to select the correct mounting hardware and mount the armature. Firmly tighten the armature mounting screw. MOUNTING THE MAGNET Mount the magnet assembly to the gate with the four selftapping screws provided. Install the anti-tamper plugs over the mounting screws with a soft mallet. VERIFY PROPER ALIGNMENT Close the gate and verify the lock face and armature are making full contact for the entire armature length. Make corrective adjustments as necessary.
SWING GATE EXAMPLES FENCE POST
GATE POST FENCE POST
GATE POST
MAG LOCK
GATE FLUSH WITH POST
NO OFFSET REQUIRED
ARMATURE
FENCE POST GATE POST
1” OFFSET MAX MAG LOCK ARMATURE
SLIDE GATE EXAMPLES
GATE POST
FENCE POST
FENCE POST GATE POST
ARMATURE MAG LOCK GATE POST
FENCE POST
ARMATURE
2
MAG LOCK
Wiring diagram
To Lock N/C terminal of gate operator control board To Lock COM terminal of gate operator control board
Mag Lock 24vDC Max, 1 Amp Max
To positive (+) terminal of mag-lock power supply To negative (-) terminal of mag-lock power supply
NOTE: GTO’s GP-Series (SL050, SL100, SW050 and SW100) operators are Magnetic Lock ready with a NORMALLY CLOSED contact Lock Terminal. GTO’s low voltage (2000XL, 3000XL, 4000XL, SL1000 and SL2000) operators do not have a NORMALLY CLOSED contact Lock Terminal and will require the addition of a NORMALLY OPEN contact relay.
Parts diagram
2
6
7
8 1
5
3
4
1. 2 3. 4. 5. 6. 7. 8. 9. 10.
9
Magnet Lock Armature Mounting Screw Anti-tamper Plug Rubber Washer Anti-spin Pin Steel Washer Armature Bolt Spacer Sex Nut
GTO Hours of Operation: Mon. – Fri., 8:00 A.M. - 7:00 P.M. (ET) Phone (800) 543-1236 • FAX (850) 575-8950 E-mail:
[email protected] • GTO Web site: www.gtoaccess.com
3
10