R3-us4 Universal Input Module Before Use .... Instruction Manual

   EMBED


Share

Transcript

R3-US4 INSTRUCTION MANUAL UNIVERSAL INPUT MODULE (4 points, isolated) BEFORE USE .... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any problems or questions with the product, please contact M-System’s Sales Office or representatives. MODEL R3-US4 ■ AND .... The unit is designed to function as soon as power is supplied, however, a warm up for 10 minutes is required for satisfying complete performance described in the data sheet. INSTALLATION ■ PACKAGE INCLUDES: Universal input module (body + 4 CJC sensors)......... (1) Use the Installation Base (model: R3-BSx). ■ MODEL NO. Confirm Model No. marking on the product to be exactly what you ordered. COMPONENT IDENTIFICATION ■ INSTRUCTION MANUAL This manual describes necessary points of caution when you use this product, including installation, connection and basic maintenance procedures. ■ FRONT VIEW RUN LED ERR LED 11 12 POINTS OF CAUTION ■ HOT INSERTION/REMOVAL OF MODULES Removing or replacing modules does not affect other modules on the same backplane. It is possible to replace them without removing the power supply. However, replacing multiple modules at once may greatly change line voltage levels. We recommend that you replace them one by one. ■ ENVIRONMENT • Indoor use • When heavy dust or metal particles are present in the air, install the unit inside proper housing with sufficient ventilation. • Do not install the unit where it is subjected to continuous vibration. Do not subject the unit to physical impact. • Environmental temperature must be within -10 to +55°C (14 to 131°F) with relative humidity within 30 to 90% RH in order to ensure adequate life span and operation. ■ WIRING • Do not install cables (power supply, input and output) close to noise sources (relay drive cable, high frequency line, etc.). • Do not bind these cables together with those in which noises are present. Do not install them in the same duct. 13 14 CJC SENSOR (4 CJMs) 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 ■ STATUS INDICATOR LED RUN indicator: Bi-color (red/green) LED; Red when connected to a host PC/PLC via internal bus A Green when connected to a host PC/PLC via internal bus B (R3-US4W only) Amber when connected to a host PC/PLC via both buses (R3-US4W only) ERR indicator: Bi-color (red/green) LED; Red with the input circuit abnormality Green in normal operating conditions ■ UNUSED INPUT CHANNELS Setting the unused channels as “Unused” with the configurator software (model: R3CON) prevents the error due to open circuit. M-SYSTEM WARRANTY M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such product was originally purchased if such product has been used under normal operating conditions and properly maintained, M-System’s sole liability, and purchaser’s exclusive remedies, under this warranty are, at M-System’s option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this warranty. To submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original sales invoice. THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES OF ANY KIND WHATSOEVER. M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: [email protected] EM-8449 Rev.1 P. 1 / 2 R3-US4 TERMINAL CONNECTIONS Connect the unit as in the diagram below. ■ DIMENSIONS mm (inch) 27.5 (1.08) 109 (4.29) POSITIONING GUIDE CJC SENSOR (4 CJMs) 12 13 14 15 16 17 18 19 20 1 20–M3 SCREW 2 3 4 5 6 6.2 (.24) 130 (5.12) 11 7 8 9 10 TERMINAL COVER ■ CONNECTION DIAGRAM BUS CONNECTOR 11 INPUT 1 1 2 13 INPUT 2 3 BUS A INPUT CONNECTION ■ DC VOLTAGE ■ THEMOCOUPLE • Upscale/no burnout BUS B* A B C + INTERNAL POWER 4 – CJC Sensor ■ RTD • Downscale burnout A + B + comp.wire – C CJC Sensor + – comp.wire A B + C ■ POTENTIOMETER 15 INPUT 3 B 6 MAX A B C A 5 B 2 MIN 17 INPUT 4 7 ■ TERMINAL NETWORK 8 A B C *For dual redundant communication. 3 1 A B – C + INPUT 1 INPUT 2 INPUT 3 INPUT 4 11 1 2 13 3 4 15 5 6 17 7 8 Note 1: Remove CJC sensor for RTD or potentiometer input. The CJC sensor does not affect to DC voltage input. Note 2: Be sure to eliminate noise as much as possible by e.g. using shielded cables. Ground the signal shield to a most stable earth point in the environment. Note 3: The temperature imbalance around the terminal affects greatly the cold junction compensation accuracy. In order to minimize such imbalance, do not expose the input terminals directly to the wind from a cooling fan. WIRING INSTRUCTIONS ■ SOLDERLESS TERMINAL mm (inch) Refer to the drawing below for recommended ring tongue terminal size. Spade tongue type is also applicable. Solderless terminals with insulation sleeve do not fit. Applicable wire size: 0.3 – 0.75 mm2 4 min. (.16) 3.2 (.13) dia. 6 max. (.24) 3 (.12) max. 12 (.47) max. EM-8449 Rev.1 P. 2 / 2