Preview only show first 10 pages with watermark. For full document please download

R6gp Series Technical Specifications Features And Benefits

   EMBED


Share

Transcript

TECHNICAL SPECIFICATIONS R6GP Series 6, 7½ and 10 Ton Packaged Gas/Electric Units 11.2 EER Commercial System 80% Steady State Efficiency with Optional Stainless Steel Heat Exchangers These units are designed specifically for retrofit applications and compatibility with most standard footprints. They take less time to install and retrofit, making the contractor's job more profitable. These units offer flexibility in the replacement market. FEATURES and BENEFITS • Quality Compressor: State of the art scroll compressor is standard equipment. • 7 ½ & 10 Ton Feature Two-Stage Cooling • 6 Ton Features Single Stage Cooling • High Efficient Blower Motor: Meets the requirements of NEMA 12/19/2010 • Hi/Low Pressure Switches: Ensure long compressor life. Featuring manual reset high pressure control. • CopperTube / Aluminum Fin Coils: Both indoor and outdoor coils are designed to optimize heat transfer, minimize size and cost, and increase durability and reliability. • Plastic Mesh Hail Guard: A guard that will never rust and protects the units coil from being damaged. • For Easy Service: Hi/low service ports allow quick access without disrupting operation. • Permanently Lubricated Condenser Fan Motors: A heavy duty PSC motor for long lasting reliability and quiet operation. Requires no maintenance and is completely protected from rain and snow. • 75 VA Transformer: Includes 4 Amp circuit breaker to protect the low voltage circuit. • Liquid Line Filter Driers: Factory installed for convenience. • Crankcase Heater: Protection from liquid flood back and future compressor failures. • Freeze Protection Thermostats: provide reliable compressor operation. • Easy Compressor and Control Access: Designed to make servicing easier for the contractor, access panels are provided to all controls and the compressor from the side of the unit. • 80% Steady State Efficiency: Aluminized steel or stainless steel heat exchanger tubes are available. • Two-Stage Heating: Provides High / Low fire operation • Direct Spark Ignition Control: With 3 amp fuse, flame sensing, and diagnostic LED • Convertible Air Delivery with Kit: Converts to horizontal airflow with side panels including duct flange and bottom close off panels. • Quick-Release Filter Access Panels: Requires no special servicing tools. • Fully Insulated Bottom Pan: Helps ensure quiet operation and prevents condensation. • Removable Top Grille Assembly: Allows ease of service to the fan motor. • Full Perimeter Base Rail System: Base rails have rigging holes and do not need to be removed for curb applications. Base rails have fork truck slots on three sides. • Durable, Attractive Cabinet: Designed using 20 gauge galvanized steel with a polyester urethane finish. The 950 hour salt spray finish is 1.5 mil thick and resists corrosion 50% better than comparable units. 2 3 High Efficiency Compressors with Crankcase Heaters High/Low Pressure Switch Protection Power Wiring Entry Condenser Coils Control Wiring Entry Knockout for Bottom Power Entry Liquid Line Filter Driers Condenser Fan Assemblies Belt Drive Blower Motor Knockout 3/4” PVC for Bottom Condensate Power Entry** Drain Evaporator Coils Flame Observation + Field Supplied ** Field Installed Kit Required Gas Line Inlet Permament Baserail No Need for Removal with Roof Curb Exhaust Vent Electrical Disconnect Mounting Panel + Easy Access Control Panel Durable Pre-Coat Paint Combustion Air Inlet Quick Release Filter Panel Model R6GP-120C235C Shown R6GP – physical data Dimensions shown in inches (mm) A Corner “D” Corner “A” Heat Exchanger CG Condenser Fans Top View Corner weights and center of gravity see Table Page 9 B Corner “C” Corner “B” Blower Assembly HIGH VOLTAGE CONNECTIONS 101 1/2 (2578) GROUND CONNECTIONS LOW VOLTAGE CONNECTIONS 4 (102) INDOOR BLOWER COMBUSTION AIR INLET INDUCER EXHAUST OUTDOOR COMPARTMENT Front View FLAME OBSERVATION PORT RECOMMENDED DISCONNECT MOUNTING LOCATION 4 (102) BOTTOM POWER KIT MOUNTING LOCATION CONDENSATE DRAIN 2 (51) 30 3/4 Horizontal Discharge Air Opening* Filter Access 30 (762) 4 (102) 16 1/2 (419) 4 (102) Condenser Coil Horz. Return Air Opening* 30 (762) 16 1/2 (419) 7 (178) 7 1/4 (184) *Shown with optional horizontal duct panels Physical Dimensions for R6GP-072 Series 4 43 1/2 (1403) Rear View R6GP – physical data (Continued) Dimensions shown in inches (mm) INDUCER EXHAUST 57 1/2 (1460) RATING LABEL RECOMMENDED LOCATION FOR UNIT DISCONNECT COMBUSTION AIR LOUVERS 43 (1092) Heat Exchanger End GAS INLET 14 5/8 (371) UNIT BASERAIL 6 5/64 (154) Airflow Airflow Compressor Condenser End 7 (178) Return Air Opening 7 (178) 5-3/4 (146) 30 1/2 (775) 16 1/2 (419) 16 1/2 (419) Bottom Pan Top View (072, 090, 120) 30 1/2 (775) Discharge Air Opening 8 3/4 (222) † Power Entry 62 (1575) 101 1/4 (2572) Physical Dimensions for R6GP-072 Series Continued 5 Dimensions shown in inches (mm) A Corner “A” Corner “D” Heat Exchanger CG Condenser Fans B Corner “B” Corner “C” Blower Assembly Top View 16 (406) Optional Hail Guard Hood Corner weights and center of gravity see Table Page 9 101 1/2 (2578) Control Access 4 (102) Field Wiring (†)Electric Element Access Blower Access Condesate Drain 4 (102) 2 (51) 30 3/4 (781) Front View Physical Dimensions for R6GP-090 Series 6 *Shown with optional horizontal duct panels Horizontal Discharge Air Opening* Filter Access 4 (102) 30 (762) Condenser Coil Horz. Return Air Opening* 43 1/2 (1403) 16 1/2 (419) 16 1/2 (419) Rear View 30 (762) 4 (102) 7 1/4 (184) INDUCER EXHAUST 7 (178) 57 1/2 (1460) RATING LABEL RECOMMENDED LOCATION FOR UNIT DISCONNECT COMBUSTION AIR LOUVERS 43 (1092) Heat Exchanger End GAS INLET 14 5/8 (371) 6 5/64 (154) UNIT BASERAIL Airflow Airflow Compressors (x2) Condenser End Physical Dimensions for R6GP-090 Series Continued 7 Dimensions shown in inches (mm) A Corner “A” Corner “D” Filters (x4) Evaporator Heat Exchanger Condenser Fans Top View B Corner “C” Corner “B” Blower Assembly 16 (406) 4 (102) 101 1/2 (2578) Optional Hail Guard Hood Control Access Inducer Exhaust Recommended Unit Disconnect Mounting Location Combustion Air Inlet Blower Access Front View Condensate Drain 4 (102) 2 (51) Compressor Electric Supply Entries *Shown with optional horizontal duct panels Horizontal Discharge Air Opening* Heat Exchanger Access 30 (762) 16 1/2 (419) 30 3/4 (781) Condenser Coils Filter Access Horiz. Return Air Opening* 30 (762) 55 1/4 (1403) 16 1/2 (419) 4 (102) 4 (102) 7 1/4 (184) 7 (178) Physical Dimensions for R6GP-120 Series 8 Rear View Airflow 57 1/2 (1461) Airflow 18 1/2 (470) Optional Fresh Air Intake Hood Condenser Coil Compressors (2) 9 7/8 (250) Optional Relief Hood 8 (203) Gas Inlet 4 (102) Condenser End Heat Exchanger End Physical Dimensions for R6GP-120 Series Continued Unit Weight ‡ Model No. Shipping Weight Center of Gravity Inches (mm) Corner Weights B C A Unit Height* D Horizontal Duct Applications Vertical Duct Applications Lbs. Kg. Lbs. Kg A B Lbs. Kg. Lbs. Kg. Lbs. Kg. Lbs. Kg. R6GP-072*-100 934 425 1069 486 48 (1219) 25 5/8 (651) 197 89 245 111 273 124 219 100 43 1/2 (1105) 38 1/4 (972) R6GP-072*-166 959 436 1094 497 49 (1245) 25 5/8 (651) 206 94 257 117 275 125 221 100 43 1/2 (1105) 38 1/4 (972) R6GP-090*-200 983 446 1118 507 55 3/8 (1407) 28 (711) 262 119 275 125 229 104 218 99 43 1/2 (1105) 38 1/4 (972) R6GP-120*-235 1301 590 1441 654 49 (1245) 30 (762) 300 136 328 149 351 159 322 146 55-1/4 (1409) 51 (1295) * Baserails are not intended to be removed. Information provided is total unit height for horizontal duct applications or height dimension added to selected roof curb height for vertical duct applications. ‡ Unit weight without packaging or field installed accessories. Center of Gravity & Unit Shipping Weights MODEL IDENTIFICATION CODE R 6 G P - C 045 C A Revision Application R = Rooftop Packaged Unit Series Gas 090 P = 11.0 - 11.9 EER Cooling Nominal Capacity (000) Btu C = U.S./Canada - Aluminized Steel Hx S = U.S./Canada - Stainless Steel Hx Heating Capacity (000) Btu Electrical Code C = 208/230-60-3 D = 460-60-3 9 PHYSICAL SPECIFICATIONS DATA Model R6GPNominal Capacity (tons) Performance Data 1,2,3 Total Gross Cooling Capacity (Btuh) Rated Net Cooling Capacity (Btuh) E.E.R. - Cooling Efficiency (Btuh/Watt) IEER - Part load Efficiency Rated Airflow - CFM Compressor Data Compressor(s) Type Quantity (number of refrigeration circuits) Unit Capacity Steps (%) Crankcase Heaters POE Oil Charge (Ea.) Refrigerant Charge (R-410a) Stage 1 Circuit Stage 2 Circuit System Pressure Switches Manual Reset High Pressure Switch (PSIG) Loss of Charge Switch (PSIG) Outdoor Fan Data Fan Diameter / Total Nominal CFM Motor - HP / RPM Quantity Outdoor Coil Data Rows / fpi Type Total Face Area (sq ft) Indoor Coil Data Rows / fpi Type Total Face Area (sq ft) Expansion Device Freeze Protection Thermostat Indoor Blower Data Blower Type (Qty.) - Wheel Diameter Drive Type Standard Blower Drive Motor 4 Motor - Hp / RPM Speeds Frame Size NEMA Efficiency Blower RPM Range Blower ESP Range (in-WC) Installed Filters Style Size[inches] (Qty.) Sound Rating Number dBA 072(C/D) 090(C/D) 120(C/D) 6 7.5 10.0 73,300 72,000 11.2 12.6 2,400 93,500 90,000 11.2 12.3 3,000 125,000 119,000 11.2 11.5 4,000 Scroll 1 100 yes 56 Oz. Scroll 2 50/50 yes 42 Oz. Scroll 2 50/50 yes 42 Oz. 240 Oz. - 168 Oz. 168 Oz. 216 Oz. 216 Oz. Cut Out: 650 +/- 10 Cut Out: 5 +/- 5, Cut In: 20 +/- 5 20” / 7000 1/3 - 1100 2 24” / 8200 1/3 - 1075 2 24” / 8200 1/3 - 1075 2 2 / 18 Cu Tube/Al Fin 17.0 2 / 19 Cu Tube/Al Fin 25.5 2 / 17 Cu Tube/Al Fin 34.0 4 / 14 4 / 14 4 / 14 Cu Tube/Al Fin Cu Tube/Al Fin Cu Tube/Al Fin 8.5 8.5 11.3 TXV TXV TXV Opens (˚F): 28 +/- 5, Closes (˚F): 57 +/- 6 Centrifugal (1) - 12 x 12 Belt Centrifugal (1) - 12 x 12 Belt Centrifugal (1) - 15 x 15 Belt 1 / 1725 1 143T Premium Eff. 715 - 971 0.1 - 1.0 1.5 / 1750 1 143T Premium Eff. 777 - 1060 0.1 - 1.3 2/1800 1 143T Premium Eff. 672 - 897 0.1 - 1.0 16x20 (4) 83.5 Disposable - 2” Pleated 16x20 (4) 85.2 16x25 (4) 85.8 Notes: 1) Certified in accordance with AHRI Standard 340/360 at the rated airflow shown and the minimum external static duct pressure allowed by the standard. ARI Rating for units with dual voltages are shown at highest rated unit voltage. 2) E.E.R. - Energy Efficiency Ratio: The EER and Net Capacity is determined @ 95˚F Outdoor DB and with air entering the evaporator at 80˚F DB / 67˚F WB 3) IEER - Intergrated Energy Efficiency Ratio: a measure of merit for part load performance of the unit. 4) Refer to Alternate Accessory Drive Table for other available motor/drive kits 10 UNIT HEATING PERFORMANCE DATA Model R6GPHeater Model High Heating Input (Btuh) 1, 2 High Heating Output (Btuh) Low Heating Input (Btuh) 1, 2 Low Heating Output (Btuh) Steady State Efficiency Number of Capacity Stages Ignition Type Number of Burners Gas Piping Connection (in) Factory Configured 3 072(C/D) -100(c,s) 100,000 80,000 65,000 52,000 80% 2 Spark 3 1/2” NPT Nat. Gas 090(C/D) -200(c,s)a 200,000 160,000 130,000 104,000 80% 2 Spark 6 1/2” NPT Nat. Gas -166(c,s) 166,000 132,800 108,000 86,400 80% 2 Spark 5 1/2” NPT Nat. Gas 120(C/D) -235(c,s)b 235,000 188,000 150,000 120,000 80% 2 Spark 7 3/4” NPT Nat. Gas Notes: 1) Units with Heating inputs of 225,000 Btuh or greater are rated in accordance with DOE 10 CFR Part 431 2) Capacities shown represent use with Natural Gas, refer to Table 10 for LP gas capacities 3) Heat Exchangers are convertible to LP with Accessory Kit Temperature Rise/AirFlow Unit Model Gas Type Heating Heating Input Output Heating Rise Range CFM Range SCFM R6GP-072*-100 Natural Gas 100,000 80,000 Propane (LP) 85,000 15 - 45 68,000 Rise (ºF)* SCFM R6GP-072*-166 Natural Gas 166,000 133,000 Propane (LP) 141,000 112,800 35 - 65 Rise (ºF)* SCFM R6GP-090*-200 Natural Gas 200,000 160,000 Propane (LP) 175,000 140,000 30 - 60 Rise (ºF)* SCFM R6GP-120*-235 Natural Gas 235,000 188,000 Propane (LP) 205,000 164,000 25 - 55 Rise (ºF)* 1950 2100 2250 2400 2550 2700 38 35 33 31 29 27 32 30 28 26 25 23 1950 2100 2250 2400 2550 2700 63 59 55 51 48 46 54 50 46 44 41 39 2425 2625 2800 3000 3188 3375 61 56 53 49 46 44 53 49 46 43 41 38 3250 3500 3750 4000 4250 4500 54 50 46 44 41 39 47 43 40 38 36 34 * At Elevations of 2000 Ft or less Orifice or drill size for natural and propane (LP) gases. Unit Model R6GP-072*-100 R6GP-072*-166 R6GP-090*-200 R6GP-120*-235 Gas Type Heating Input Natural Gas 100,000 Propane (LP) 85,000 Natural Gas 166,000 Propane (LP) 141,000 Natural Gas 200,000 Propane (LP) 175,000 Natural Gas 235,000 Propane (LP) 205,000 Number of Burners 3 5 6 7 Orifice Size for Increased Elevation* (Above Sea Level) 0-2,000 Ft 2,001-4,000 Ft 4,001-6,000 Ft 6,001-8,000 Ft 8,001-10,000 Ft 36 38 40 41 43 53 54 54 55 55 36 38 40 41 43 53 54 54 55 55 36 38 40 41 43 51 52 52 52 53 36 38 40 41 43 51 52 52 52 53 * Refer to Instructions for High Altitude Deration to determine heat-exchanger capacity at increased elevations. Table 10. Approximate Orifice or Drill Size for Natural and Propane (LP) Gases. 11 ELECTRICAL DATA FOR POWER EXHAUST ACCESSORY KITS Part # † Volts HP CFM FLA Fuse MCA MOP R6GP-072 & 090 547867 230 1/2 2350 3.00 6A 3.75 6.75 R6GP-072 & 090 547868 460 1/2 2350 1.50 3A 1.88 3.38 Model R6GP-120 547876 230 3/4 4900 4.00 9A 5.00 9.00 R6GP-120 547877 460 3/4 4900 2.00 4A 2.50 4.50 Indoor Motor 4 Inducer Motor † See Accessory List, pg 22 ELECTRICAL DATA Model Number 2,3 Nominal Unit Voltage 1 Factory Unit Electrical Data: R6GP -072-(100/166) 208-230 V -072-(100/166) 460 V Compressors Outdoor motors (2) ea. QTY 1 ea. 1 ea. RLA 19 9.7 LRA 123 62 FLA 1.5 0.8 Hp 1 FLA 3.2-3.1 1.5 Hp FLA LRA 1/12 0.5 0.76 Total Unit RLA Unit Only Circuit FLA 25.2 12.8 MCA 30-30 16 MOP 45-45 20 -090-200 -090-200 208-230 V 460 V 2 ea. 2 ea. 13.1 6.1 83.1 41 2.3 1.2 1.5 4.4-4.2 2.1 1/12 0.5 0.76 35.2 16.7 39-39 19 50-50 20 -120-235 -120-235 208-230 V 460 V 2 ea. 2 ea. 16.0 7.8 110 52 2.3 1.2 2 6.0-5.8 2.9 1/12 0.5 0.76 42.6 20.9 47-47 23 60-60 30 Notes: 1) To achieve the rated unit performance, unit voltage should be within 2% of 4) Indoor Motors meet 2010 DOE requirements (Premium Efficient) nominal. 5) FLA = Full Load Amps MCA = Minimum Circuit Ampacity 2) For C series units: RLA = Rated Load Amps MOP = Maximum Over-Current Protection Nominal Unit Input Voltage = 208-230 Volt, 60 Hertz, 3 Phase LRA = Locked Rotor Amps Minimum allowed unit voltage = 187V Maximum allowed voltage = 253V 3) For D series units: Nominal Unit Input Voltage = 460 Volt, 60 Hertz, 3 Phase Minimum allowed unit voltage = 414V Maximum allowed voltage = 506V 12 R6GP - EXPANDED RATINGS, COOLING MODE R6GP-072-(100/166) CFM 2250 O.D.T E.D.B. E.W.B. 62 67 75 72 T.C. 68.4 76.1 84.7 85°F S.C. 52.3 41.1 32.3 kW 5.64 5.73 5.82 T.C. 63.1 70.6 78.7 95°F S.C. 49.9 39.0 30.2 kW 6.24 6.33 6.41 T.C. 57.7 65.0 72.8 105°F S.C. 47.6 36.8 28.2 kW 6.85 6.92 7.01 T.C. 52.4 59.5 66.8 115°F S.C. 45.2 34.7 26.1 kW 7.46 7.52 7.60 80 62 67 72 68.7 76.1 84.1 63.0 52.3 41.5 5.65 5.74 5.85 63.7 71.4 78.8 60.5 50.3 39.4 6.21 6.28 6.37 58.6 66.7 73.4 57.9 48.2 37.2 6.78 6.83 6.89 54.4 60.7 67.0 54.2 45.5 34.5 7.47 7.54 7.55 75 62 67 72 69.2 77.1 85.9 54.2 42.4 32.3 5.73 5.81 5.92 63.9 71.6 79.9 51.7 40.0 30.5 6.34 6.41 6.51 58.6 66.2 73.8 49.3 37.6 28.7 6.95 7.01 7.10 53.3 60.7 67.8 46.8 35.2 26.9 7.55 7.61 7.70 80 62 67 72 69.7 77.0 85.1 64.4 54.1 42.7 5.75 5.82 5.92 65.1 72.0 79.5 61.4 51.7 40.3 6.35 6.43 6.50 60.5 65.9 73.9 58.5 49.4 37.9 6.95 7.08 7.09 55.9 60.4 68.2 55.6 47.0 35.5 7.55 7.71 7.67 75 62 67 72 70.0 78.0 87.0 56.0 43.7 32.2 5.82 5.89 6.01 64.7 72.7 81.0 53.5 41.0 30.7 6.43 6.50 6.61 59.5 67.3 74.9 50.9 38.4 29.1 7.04 7.10 7.20 54.2 61.9 68.8 48.4 35.7 27.6 7.65 7.71 7.79 80 62 67 72 70.6 77.9 86.1 65.8 56.0 43.9 5.85 5.90 5.98 66.2 72.6 80.6 62.8 53.4 41.4 6.45 6.50 6.59 62.5 67.4 75.0 60.9 50.9 38.9 6.97 7.11 7.19 57.3 62.2 69.5 56.9 48.3 36.4 7.63 7.71 7.79 55°F S.C. kW 65°F S.C. kW 75°F S.C. kW 85°F S.C. kW 2400 2550 R6GP-072-(100/166) CFM O.D.T E.D.B. E.W.B. T.C. T.C. T.C. T.C. 75 62 67 72 78.6 86.8 95.0 57.9 46.7 36.1 4.49 4.59 4.70 75.2 83.2 91.6 56.0 44.8 34.8 4.87 4.97 5.07 71.8 79.7 88.1 54.2 43.0 33.6 5.25 5.35 5.45 68.4 76.1 84.7 52.3 41.1 32.3 5.64 5.73 5.82 80 62 67 72 79.2 87.3 95.0 68.9 58.2 45.6 4.47 4.57 4.69 75.8 83.8 91.6 66.9 56.3 44.3 4.85 4.95 5.06 72.8 80.6 88.8 65.5 54.9 43.5 5.21 5.31 5.41 68.7 76.1 84.1 63.0 52.3 41.5 5.65 5.74 5.85 75 62 67 72 79.6 87.6 95.6 59.7 48.0 36.0 4.58 4.68 4.79 76.1 84.1 92.4 57.8 46.1 34.8 4.97 5.06 5.17 72.6 80.6 89.1 56.0 44.3 33.5 5.35 5.44 5.54 69.2 77.1 85.9 54.2 42.4 32.3 5.73 5.81 5.92 80 62 67 72 80.2 88.1 95.6 70.6 59.5 45.5 4.57 4.66 4.78 76.7 84.6 92.4 68.7 57.6 44.2 4.95 5.03 5.15 73.6 81.5 89.8 67.3 56.2 43.4 5.31 5.39 5.50 69.7 77.0 85.1 64.4 54.1 42.7 5.75 5.82 5.92 75 62 67 72 80.5 88.3 96.2 61.5 49.3 35.9 4.68 4.77 4.88 77.0 84.9 93.1 59.6 47.4 34.7 5.06 5.15 5.26 73.5 81.5 90.1 57.8 45.6 33.4 5.44 5.52 5.64 70.0 78.0 87.0 56.0 43.7 32.2 5.82 5.89 6.01 80 62 67 72 81.1 88.8 96.2 72.4 60.8 45.4 4.66 4.75 4.88 77.6 85.5 93.2 70.5 58.9 44.1 5.04 5.12 5.24 74.5 82.4 90.8 69.2 57.5 43.4 5.40 5.48 5.60 70.6 77.9 86.1 65.8 56.0 43.9 5.85 5.90 5.98 2250 2400 2550 Notes: 1) T.C. = Total (Net) Cooling Capacity, S.C. = Sensible Cooling Capacity, kW = Kilowatts 2) Expanded Ratings are based on 230 Volt - 60 Hz operation 3) Ratings based on Factory Standard Blower Drive 4) Bolded Values indicate ARI rating points 5) Energy Efficiency Ratio (EER) = T.C. / kW 13 R6GP - EXPANDED RATINGS, COOLING MODE R6GP-090 (Two Compressor Operation) CFM O.D.T E.D.B. E.W.B. 62 67 72 T.C. 85.3 93.3 101.9 85°F S.C. 65.2 52.4 39.3 K.W. 7.08 7.19 7.31 T.C. 81.3 88.8 97.3 95°F S.C. 63.9 51.2 38.0 K.W. 7.74 7.84 7.97 T.C. 73.4 80.1 87.7 105°F S.C. 62.7 50.0 36.7 K.W. 8.84 8.94 9.06 T.C. 68.5 74.8 82.0 115°F S.C. 61.2 48.6 35.3 K.W. 9.39 9.46 9.59 80 62 67 72 86.0 92.9 101.7 76.5 64.4 51.4 7.09 7.18 7.31 82.2 88.6 97.0 75.5 63.4 50.4 7.75 7.84 7.96 74.3 80.0 87.5 74.5 62.4 49.3 8.85 8.94 9.06 69.8 74.7 81.6 73.6 61.2 48.1 9.40 9.46 9.58 75 62 67 72 86.8 94.6 103.5 69.4 55.2 40.4 7.27 7.38 7.51 82.7 90.0 98.6 68.1 54.0 39.1 7.93 8.03 8.17 74.5 80.9 88.8 66.8 52.7 37.8 9.05 9.14 9.27 69.5 75.3 82.9 65.3 51.3 36.3 9.57 9.64 9.78 80 62 67 72 87.9 94.5 103.1 81.9 68.5 54.2 7.29 7.38 7.51 84.3 90.0 98.2 81.8 67.5 53.1 7.96 8.04 8.16 76.6 81.2 88.4 80.3 66.5 52.0 9.08 9.14 9.26 72.2 75.6 82.5 76.4 65.3 50.9 9.60 9.65 9.78 75 62 67 72 87.9 95.3 104.6 73.3 57.8 41.4 7.46 7.57 7.71 83.7 90.3 99.5 72.0 56.5 40.1 8.12 8.22 8.36 75.3 81.2 89.6 70.7 55.1 38.7 9.24 9.32 9.46 70.2 75.7 83.5 69.1 53.6 37.3 9.75 9.82 9.95 80 62 67 72 90.3 95.6 104.1 88.4 72.5 56.8 7.50 7.57 7.70 86.7 91.1 98.9 86.3 71.4 55.7 8.16 8.23 8.35 78.7 82.0 88.9 78.3 70.4 54.7 8.49 8.56 8.68 74.0 76.6 82.4 73.7 69.2 53.4 9.80 9.83 9.95 75 2825 3000 3188 R6GP-090 (One Compressor Operation) CFM O.D.T E.D.B. E.W.B. 75 2825 80 75 3000 80 75 3190 80 T.C. 55 °F S.C. kW T.C. 65 °F S.C. kW T.C. 75 °F S.C. kW T.C. 85 °F S.C. kW 62 67 72 62 67 72 62 67 72 62 67 72 62 67 72 58.5 64.7 71.7 59.3 64.6 70.5 59.0 65.3 72.2 59.8 65.1 71.1 59.5 65.8 72.7 52.6 44.3 35.0 59.3 57.4 49.5 53.7 45.3 36.1 59.8 58.4 50.6 55.3 47.0 37.8 3.74 3.81 3.90 3.78 3.85 3.92 3.77 3.85 3.93 3.82 3.88 3.95 3.77 3.84 3.92 52.5 58.8 65.8 53.3 58.7 64.6 53.1 59.4 66.3 53.9 59.2 65.1 53.6 59.8 66.8 47.2 38.9 29.7 53.3 52.0 44.1 48.3 40.0 30.8 53.9 53.1 45.2 50.0 41.6 32.4 3.88 3.95 4.04 3.92 3.98 4.06 3.91 3.99 4.07 3.96 4.02 4.09 3.90 3.98 4.06 48.0 54.3 61.3 48.8 54.2 60.1 48.6 54.9 61.8 49.4 54.7 60.6 49.1 55.3 62.3 44.1 35.8 26.6 48.8 48.9 41.0 45.2 36.9 27.6 49.4 50.0 42.1 46.8 38.5 29.3 4.10 4.18 4.26 4.15 4.21 4.28 4.14 4.21 4.30 4.18 4.24 4.32 4.13 4.20 4.29 45.0 51.3 58.2 45.8 51.1 57.0 45.5 51.8 58.8 46.3 51.6 57.6 46.0 52.3 59.2 43.2 34.9 25.7 45.8 48.0 40.1 44.3 36.0 26.8 46.3 49.1 41.2 46.0 37.6 28.4 4.42 4.49 4.57 4.46 4.52 4.59 4.45 4.53 4.61 4.49 4.56 4.63 4.44 4.52 4.60 62 67 72 60.3 65.6 71.5 60.3 60.1 52.2 3.81 3.87 3.94 54.4 59.7 65.6 54.4 54.7 46.9 3.95 4.01 4.08 49.9 55.2 61.1 49.9 51.6 43.7 4.17 4.24 4.31 46.8 52.1 58.0 46.8 50.7 42.9 4.49 4.55 4.62 Notes: 1 ) T.C. = total (Net) cooling in kBtuh; S.C. = Sensible Cooling in kBtuh; kW = Kilowatts 2 ) Ratings are based on the Factory Standard blower drive combination 3 ) For 208-230V Units, the ratings shown reflect 230V operation 4 ) Bolded Values indicate AHRI rating points 5 ) Energy Efficiency Ratio (EER) = T.C./kW 14 R6GP - EXPANDED RATINGS, COOLING MODE R6GP-120 (Two Compressor Operation) CFM O.D.T E.D.B. 75 3500 80 75 4000 80 75 4500 80 E.W.B. T.C. 85°F S.C. K.W. T.C. 95°F S.C. K.W. T.C. 105°F S.C. K.W. T.C. 62 67 72 62 67 72 62 67 72 62 67 72 62 67 72 62 67 72 112.7 123.3 134.7 113.7 122.8 134.4 114.8 125.0 136.8 116.2 124.9 136.3 116.2 125.9 138.2 119.4 126.4 137.6 86.5 69.6 52.2 101.5 85.5 68.3 92.1 73.3 53.6 108.8 91.0 71.9 97.4 76.8 55.0 117.4 96.2 75.4 9.36 9.50 9.67 9.37 9.49 9.67 9.62 9.76 9.93 9.64 9.75 9.93 9.87 10.00 10.19 9.91 10.01 10.18 107.5 117.4 128.6 108.6 117.2 128.2 109.3 118.9 130.3 111.5 119.0 129.8 110.7 119.4 131.6 114.6 120.4 130.7 84.9 68.0 50.5 100.3 84.2 66.9 90.4 71.6 51.9 108.6 89.6 70.5 95.6 75.0 53.2 114.6 94.9 74.0 10.24 10.37 10.53 10.25 10.36 10.53 10.49 10.62 10.80 10.52 10.62 10.79 10.74 10.86 11.05 10.79 10.88 11.04 97.0 105.9 115.9 98.2 105.7 115.6 98.5 107.0 117.4 101.3 107.3 116.9 99.6 107.3 118.4 104.0 108.5 117.5 83.3 66.3 48.7 98.9 82.8 65.5 88.7 70.0 50.1 106.6 88.3 69.1 93.9 73.2 51.4 104.0 93.5 72.6 11.68 11.82 11.98 11.71 11.82 11.98 11.96 12.08 12.25 12.01 12.09 12.25 12.22 12.33 12.51 11.22 11.31 11.48 90.5 98.8 108.4 92.3 98.8 107.9 91.8 99.6 109.6 95.4 100.0 109.1 92.8 100.0 110.4 97.8 101.2 108.9 115°F S.C. K.W. 81.3 64.5 46.9 97.8 81.3 63.9 86.7 68.1 48.2 101.5 86.7 67.6 91.8 71.2 49.5 97.8 91.9 70.9 12.41 12.50 12.68 12.43 12.51 12.67 12.65 12.74 12.93 12.69 12.75 12.92 12.89 12.98 13.16 12.95 13.00 13.16 R6GP-120 (One compressor operation) CFM 3500 4000 4500 O.D.T E.D.B. E.W.B. 75 62 67 72 80 62 67 72 75 62 67 72 80 62 67 72 75 62 67 72 80 62 67 72 T.C. 65.9 73.8 82.6 69.9 76.7 84.2 66.9 74.9 83.7 68.8 75.5 83.0 68.0 75.9 84.7 67.9 74.4 82.3 55 °F S.C. 49.1 37.5 27.7 58.8 47.9 36.5 50.5 38.8 28.8 58.9 48.4 37.5 51.9 40.0 29.9 59.0 49.0 38.1 kW 4.50 4.70 4.80 4.30 4.50 4.60 4.90 5.00 5.20 5.00 5.10 5.20 5.20 5.40 5.50 5.60 5.70 5.70 T.C. 61.8 69.8 78.6 65.9 72.6 80.1 62.9 70.8 79.6 64.8 71.5 79.0 64.0 71.9 80.7 63.9 70.4 78.2 65 °F S.C. 46.9 35.3 25.5 56.6 45.6 34.3 48.3 36.5 26.6 56.7 46.2 35.3 49.7 37.8 27.7 56.8 46.7 35.9 kW 4.80 5.00 5.10 4.60 4.70 4.90 5.20 5.30 5.40 5.20 5.30 5.40 5.50 5.60 5.80 5.90 5.90 6.00 T.C. 56.8 64.7 73.5 60.9 67.6 75.1 57.9 65.8 74.6 59.8 66.5 74.0 58.9 66.9 75.7 58.9 65.4 73.2 75 °F S.C. 44.3 32.7 22.9 54.0 43.1 31.7 45.7 34.0 24.0 54.1 43.6 32.7 47.1 35.2 25.1 54.2 44.1 33.3 kW 5.10 5.30 5.50 5.00 5.10 5.20 5.50 5.60 5.80 5.60 5.70 5.80 5.80 6.00 6.10 6.20 6.30 6.30 T.C. 50.7 58.7 67.5 54.8 61.5 69.0 51.8 59.7 68.5 53.7 60.4 67.9 52.9 60.8 69.6 52.8 59.3 67.1 85 °F S.C. 41.4 29.8 19.9 51.0 40.1 28.8 42.8 31.0 21.0 51.2 40.7 29.7 44.2 32.2 22.1 51.3 41.2 30.3 kW 5.50 5.70 5.90 5.30 5.50 5.60 5.90 6.00 6.20 6.00 6.10 6.20 6.20 6.40 6.50 6.60 6.70 6.70 Notes: 1 ) T.C. = total (Net) cooling in kBtuh; S.C. = Sensible Cooling in kBtuh; kW = Kilowatts 2 ) Ratings are based on the Factory Standard blower drive combination 3 )For 208-230V Units, the ratings shown reflect 230V operation 4 ) Bolded Values indicate AHRI rating points 5 ) Energy Efficiency Ratio (EER) = T.C./kW 15 BLOWER PERFORMANCE DATA 2588 719 0.72 R6GP-072-100 Factory Standard: 1 Hp Down-flow Performance Chart Extended Unit Static (in-Wg) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Operating @ 230 or 460 Volts Indicates a recommended unit operational point 2793 715 0.77 Indicates an allowable setting that is not recommended for unit operation † † These operational points should be carefully examined by the installer for proper unit setup and heating operation Indicates a setting that is not permitted for unit operation ‡ Indicates Factory Sheave Setting Adjustable Motor Sheave Setting Fully Closed CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW 1/2 Turn Open 2417 960 1.02 2105 964 0.88 1 Turn Open 2528 936 0.97 2220 940 0.85 1854 944 0.77 1.5 Turns Open 2582 908 0.98 2301 912 0.86 2111 908 0.79 2 Turns Open 2680 880 0.97 2399 884 0.86 2074 888 0.76 2.5 Turns Open 2727 854 0.95 2488 858 0.86 2177 862 0.76 1913 866 0.68 3 Turns Open 2975 824 0.98 2763 828 0.95 2582 831 0.86 2295 835 0.76 1913 866 0.68 3.5 Turns Open 2828 800 0.88 2608 804 0.84 2381 808 0.75 2105 801 0.63 R6GP-072-100 Factory Standard: 1 Hp Horizontal Performance Chart Extended Unit Static (in-Wg) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Operating @ 230 or 460 Volts CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW 2867 771 0.85 2680 775 0.79 2453 760 0.72 2180 784 0.65 1860 786 0.54 4.5 Turns Open 5 Turns Open ‡ 2946 741 0.85 2728 745 0.78 2528 749 0.72 2293 746 0.63 1982 750 0.56 2793 715 0.77 2588 719 0.72 2375 722 0.65 2110 726 0.57 ‡ Indicates Factory Sheave Setting Adjustable Motor Sheave Setting Fully Closed 1/2 Turn Open 2414 959 1.04 2174 964 0.90 1 Turn Open 2545 931 1.02 2306 936 0.92 2013 941 0.81 1.5 Turns Open 2563 903 1.00 2353 907 0.91 2046 912 0.79 2 Turns Open 2626 877 0.99 2349 879 0.87 2100 833 0.78 Values includes losses for: Unit Casing, 2" Disposable (Pleated) Filters & Dry Evaporator Coil For approximate Cfm at 208V Deduct 0.5% 16 4 Turns Open 2.5 Turns Open 2729 850 0.97 2462 853 0.87 2165 855 0.77 1862 858 0.68 3 Turns Open 2812 821 0.96 2590 826 0.85 2298 829 0.76 2018 833 0.68 3.5 Turns Open 2881 792 0.92 2663 795 0.85 2426 799 0.77 2026 800 0.64 4 Turns Open 2955 764 0.88 2738 766 0.81 2514 769 0.74 2261 772 0.68 1957 775 0.58 4.5 Turns Open 5 Turns Open ‡ 2999 740 0.86 2785 742 0.79 2558 745 0.72 2289 745 0.68 1995 746 0.60 2848 717 0.76 2615 720 0.69 2377 723 0.64 2085 721 0.56 1802 730 0.46 BLOWER PERFORMANCE DATA R6GP-072-166 Factory Standard: 1 Hp Down-flow Performance Chart Extended Unit Static (in-Wg) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Operating @ 230 or 460 Volts ‡ Indicates Factory Sheave Setting Adjustable Motor Sheave Setting Fully Closed CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW 1/2 Turn Open 2449 964 1.01 2160 971 0.92 1 Turn Open 2525 937 1.01 2216 941 0.88 1928 946 0.81 1.5 Turns Open 2625 909 1.01 2323 915 0.89 2004 919 0.79 2 Turns Open 2.5 Turns Open 2826 857 0.99 2544 860 0.90 2220 864 0.78 1920 868 0.68 2769 881 1.04 2395 887 0.86 2120 892 0.77 3 Turns Open 2879 831 0.96 2647 834 0.87 2318 838 0.77 2044 840 0.70 3.5 Turns Open 2936 802 0.94 2708 804 0.87 2437 808 0.78 2107 811 0.67 R6GP-072-166 Factory Standard: 1 Hp Horizontal Performance Chart Extended Unit Static (in-Wg) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Operating @ 230 or 460 Volts CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW CFM RPM kW 2989 775 0.92 2788 776 0.85 2537 777 0.79 2227 782 0.68 1895 784 0.57 4.5 Turns Open 5 Turns Open ‡ 3025 721 0.88 2832 749 0.83 2613 751 0.76 2335 753 0.68 2016 756 0.59 2872 719 0.80 2674 722 0.74 2437 725 0.68 2132 726 0.57 ‡ Indicates Factory Sheave Setting Adjustable Motor Sheave Setting Fully Closed 1/2 Turn Open 2254 971 0.96 1 Turn Open 2572 939 1.07 2303 942 0.95 2043 945 0.85 1.5 Turns Open 2668 912 1.05 2386 971 0.93 2097 920 0.83 2 Turns Open 2.5 Turns Open 2745 884 1.02 2474 888 0.92 2200 894 0.79 Values includes losses for: Unit Casing, 2" Disposable (Pleated) Filters & Dry Evaporator Coil For approximate Cfm at 208V Deduct 0.5% 17 4 Turns Open 2569 862 0.89 2285 865 0.80 1988 870 0.70 3 Turns Open 2879 833 0.97 2655 837 0.89 2392 839 0.77 2095 842 0.69 3.5 Turns Open 2704 807 0.86 2457 811 0.78 2169 813 0.59 4 Turns Open 2771 778 0.84 2529 781 0.75 2259 785 0.67 1946 789 0.60 4.5 Turns Open 2620 755 0.75 2366 757 0.68 2060 760 0.59 5 Turns Open ‡ 2914 724 0.80 2703 728 0.74 2469 731 0.66 2203 732 0.60 BLOWER PERFORMANCE DATA R6GP-090-200 Factory Standard: 1 Hp Down-flow Performance Chart Extended Unit Static (in-Wg) 0.1 Operating @ 230 or 460 Volts ‡ Indicates Factory Sheave Setting Adjustable Motor Sheave Setting 3.5 Turns Open 4 Turns Open 4.5 Turns Open 5 Turns Open ‡ 5.5 Turns Open 6 Turns Open CFM 3666 3549 3495 3441 3325 3209 RPM 867 843 832 820 799 777 kW 1.49 1.36 1.33 1.29 1.18 1.07 3496 3378 3316 3253 3137 3021 Fully Closed 1/2 Turn Open 1 Turn Open 1.5 Turns Open 2 Turns Open 2.5 Turns Open CFM 0.2 0.3 0.4 0.5 0.6 3613 RPM 893 870 846 834 822 800 778 kW 1.52 1.40 1.28 1.25 1.21 1.11 1.01 CFM 3439 3315 3190 3135 3080 2946 2811 RPM 895 872 849 836 823 802 780 kW 1.45 1.33 1.20 1.17 1.13 1.03 0.94 CFM 3384 3267 3139 3010 2945 2879 2736 2592 RPM 918 896 875 853 839 824 803 782 kW 1.48 1.37 1.25 1.12 1.09 1.06 0.96 0.86 CFM 3332 3213 3094 2943 2791 2726 2661 2503 RPM 943 921 898 878 857 842 826 805 kW 1.49 1.38 1.28 1.16 1.05 1.01 0.98 0.88 2479 CFM 3312 3195 3039 2883 2727 2571 RPM 968 946 924 902 881 860 845 0.95 0.92 1.52 1.40 1.29 1.19 1.07 CFM 3255 3128 3001 2825 2648 2469 RPM 993 971 949 927 905 885 kW 1.54 1.42 1.31 1.19 1.08 0.97 kW 0.7 0.8 0.9 CFM 3164 3059 2903 2747 2574 RPM 1010 996 974 952 931 kW 1.52 1.44 1.31 1.19 1.09 CFM 2962 2830 2669 2508 RPM 1014 1001 979 956 1.20 1.08 1.39 1.31 CFM 2904 2754 2572 RPM 1039 1018 1005 kW 1.40 1.28 1.19 kW 1.0 1.1 CFM 2693 2528 RPM 1043 1024 kW 1.30 1.17 CFM 1.2 RPM kW CFM 1.3 RPM kW Values includes losses for: Unit Casing, 2" Disposable (Pleated) Filters & Dry Evaporator Coil For approximate Cfm at 208V Deduct 0.5% 18 3 Turns Open BLOWER PERFORMANCE DATA R6GP-120-235 Factory Standard: 2Hp Down-flow Performance Chart External Unit Static (in-Wg) Operating @ 230 or 460 Volts 0.1 0.2 ‡ Indicates Factory Sheave Setting for Pre-configured Units Adjustable Motor Sheave Setting 4 Turns Open 4.5 Turns Open 5 Turns Open ‡ 5.5 Turns Open 6 Turns Open CFM 5061 4896 4731 4558 4384 RPM 736 715 694 673 651 Fully Closed 1/2 Turn Open 1 Turn Open 1.5 Turns Open 2 Turns Open 2.5 Turns Open 3 Turns Open 3.5 Turns Open kW 1.86 1.72 1.57 1.44 1.31 CFM 4849 4679 4508 4321 4134 RPM 737 716 696 674 653 kW 0.3 0.4 1.77 1.63 1.49 1.35 1.22 CFM 5005 4816 4627 4447 4267 4071 3875 RPM 781 760 738 718 697 676 655 kW 2.01 1.83 1.66 1.52 1.38 1.25 1.12 CFM 4773 4593 4413 4202 3990 3777 3564 RPM 782 762 741 720 698 678 657 kW 0.5 1.92 1.74 1.56 1.42 1.29 1.15 1.02 CFM 4719 4534 4336 4137 3923 3708 3477 3245 RPM 803 783 764 744 722 699 679 659 1.05 0.92 kW CFM 0.6 0.7 4685 0.9 1.1 1.2 1.3 1.4 1.61 1.43 1.30 1.18 4059 3845 3603 3361 826 806 786 766 746 724 703 kW 2.04 1.85 1.66 1.50 1.33 1.19 1.05 CFM 4457 4236 4014 3773 3531 3243 RPM 828 808 788 768 747 727 kW 1.91 1.72 1.54 1.37 1.20 1.06 4188 3940 3692 3412 4601 4395 RPM 867 849 832 811 791 771 kW 2.15 1.97 1.78 1.59 1.40 1.22 CFM 4326 4110 3893 3609 3325 RPM 870 853 835 814 793 kW 2.01 1.82 1.63 1.44 1.26 3998 3765 3531 3252 CFM 1.0 1.79 4273 RPM CFM 0.8 1.98 4479 4251 RPM 890 872 855 839 817 kW 2.03 1.82 1.64 1.45 1.28 3192 CFM 3917 3675 3434 RPM 894 874 858 842 kW 1.83 1.66 1.48 1.31 3358 CFM 3845 3605 RPM 910 897 878 kW 1.89 1.68 1.51 3274 CFM 3551 RPM 913 900 kW 1.73 1.53 CFM 3168 RPM 916 kW 1.56 Values includes losses for: Unit Casing, 2" Disposable (Pleated) Filters & Dry Evaporator Coil For approximate Cfm at 208V Deduct 0.5% 19 BLOWER PERFORMANCE DATA R6GP-120-235 Factory Standard: 2Hp Horizontal Performance Chart External Unit Static (in-Wg) Operating @ 230 or 460 Volts 0.1 0.2 ‡ Indicates Factory Sheave Setting for Pre-configured Units Adjustable Motor Sheave Setting Fully Closed 1/2 Turn Open 1 Turn Open 1.5 Turns Open 2 Turns Open 2.5 Turns Open 3 Turns Open 3.5 Turns Open 4 Turns Open 4.5 Turns Open 5 Turns Open ‡ 5.5 Turns Open 6 Turns Open CFM 5020 4871 4722 4536 4350 RPM 736 717 697 675 653 kW 1.82 1.68 1.53 1.41 1.29 CFM 4783 4619 4454 4271 4087 RPM 738 718 698 676 655 kW 0.3 0.4 1.73 1.59 1.45 1.33 1.20 CFM 4986 4785 4584 4407 4229 4030 3831 RPM 779 760 740 720 699 678 656 kW 2.00 1.82 1.64 1.50 1.36 1.24 1.12 CFM 4720 4519 4317 4120 3922 3727 3532 RPM 783 762 742 722 701 680 659 kW CFM 0.5 4661 0.7 1.0 1.1 1.2 1.3 1.4 1.39 1.26 1.14 1.02 3858 3643 3436 3229 805 786 765 744 724 703 682 661 1.94 1.76 1.59 1.42 1.29 1.15 1.04 0.92 4445 4252 4037 3821 3569 3316 4637 RPM 827 808 789 767 746 726 706 kW 1.99 1.82 1.64 1.48 1.32 1.18 1.05 CFM 4394 4191 3988 3745 3502 3238 RPM 830 811 792 770 747 728 kW 1.88 1.70 1.53 1.36 1.20 1.06 4173 3916 3658 3422 3186 4350 RPM 851 833 814 794 773 751 kW 1.93 1.76 1.57 1.39 1.23 1.07 4058 3861 3601 3341 CFM 0.9 1.53 4072 kW CFM 0.8 1.71 4265 RPM CFM 0.6 1.90 4458 4254 RPM 870 853 836 816 796 kW 1.97 1.80 1.62 1.44 1.26 3270 CFM 4191 3982 3762 3542 RPM 891 874 856 839 816 kW 1.99 1.81 1.64 1.47 1.30 3218 CFM 3892 3685 3452 RPM 894 877 860 843 kW 1.83 1.65 1.49 1.32 3362 CFM 3861 3572 RPM 913 897 883 kW 1.88 1.68 1.51 3244 CFM 3500 RPM 915 902 kW 1.70 1.52 CFM 3191 RPM 917 kW 1.55 Values includes losses for: Unit Casing, 2” Disposable (Pleated) Filters & Dry Evaporator Coil For operation at 208V: Deduct approximately 0.5% from Cfm 20 ACCESSORIES - 6, 7 1/2 and 10 Ton R6GP Part # 559914 547881 547860 547861 547862 547863 559411 558857 547864 547874 547865 559375 559374 920233 547848 547867 547868 547876 547877 547869 547870 547871 547878 547879 547880 558863 558866 558864 558865 920463 920612 920610 920465 917165 920619 920937 Description Horizontal Supply & Return Kit Horizontal Supply & Return Kit Hinged Roof Curb 8” High - K/D Hinged Roof Curb 14” High - K/D Hinged Roof Curb 18” High - K/D Hinged Roof Curb 24” High - K/D Hooded Hail Guard Hooded Hail Guard 0-35% Manual Outside Air Damper 0-35% Manual Outside Air Damper 0-35% Motorized Damper - Only (Requires 547864 OR 547874) Economizer - Modulating w/ Relief, Adapts Horizontal, Enthalpy Control Economizer - Modulating w/ Relief, Adapts Horizontal, Enthalpy Control Sensor, Enthalpy, C7400A (For Economizer Differential Enthalpy Control) CO2 Sensor for economizer control - 4-9v dc Power Exhaust - Prop (208/230V - 3Ø), Adapts Horizontal See Note Power Exhaust - Prop (460V - 3Ø), Adapts Horizontal See Note Power Exhaust - Prop (208/230V - 3Ø), Adapts Horizontal See Note Power Exhaust - Prop (460V - 3Ø), Adapts Horizontal See Note 20” Supply & Return Transition Round 20” Flush Mount Concentric Diffuser Round 20” Step Down Concentric Diffuser Round 18” x 28” Supply & Return Transition 18” x 28” Flush Mount Concentric Diffuser 18” x 28” Step Down Concentric Diffuser Duct Smoke Detector Photo Elect. Duct Smoke Detector, Remote Multi-signal control SSK 451 Smoke Detector Sampling Tube DST3, 2-4 ft. Smoke Detector Sampling Tube DST5, 4-8 ft. Low Ambient Kit Natural Gas - High Altitude Application Kit LP Gas - Conversion & High Altitude Application Kit Bottom Power Entry Kit Bottom Power Entry Kit Thermostat-3 Stage Heat/2 Stage Cool Flue Exhaust Extension Kit Weight 39 49 70 125 155 220 62 62 30 41 15 125 181 072 X 090 X X X X X n/a X X X X X X X X X X X X X X X X X X X 143 143 152 152 38 154 157 36 162 193 3 1 120 X X X X X X X X X X X X X X X X 7 7 10 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Note: Requires separate branch circuit, see table Electrical Data For Power Exhaust Accessory Kits, page 12. Accessory Performance Data R6GP -072* & -090* -120* Air Volume (CFM) 2200 2400 2600 2800 3000 3200 3400 3600 3600 3800 4000 4200 4400 4600 Total Resistance (inches water column) † Wet Evaporator Coil Down Flow Economizer Horizontal Economizer 0.08 0.10 0.12 0.14 0.16 0.18 0.20 0.22 0.12 0.13 0.14 0.16 0.18 0.20 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.20 0.22 0.24 0.27 0.30 0.33 0.03 0.04 0.04 0.04 0.04 0.05 0.05 0.05 0.04 0.04 0.04 0.05 0.05 0.05 Step Down Diffuser System Flush Mount 2 Ends Open 2 Ends Open w/1 Side Open 2 Ends Open w/2 Sides Open Throw ‡ (Ft) Diffuser System Throw ‡ (Ft) 0.15 0.16 0.20 0.25 0.30 0.40 0.50 0.60 0.35 0.40 0.45 0.50 0.55 0.60 0.14 0.16 0.20 0.25 0.30 0.38 0.46 0.55 0.25 0.30 0.35 0.40 0.45 0.50 0.13 0.13 0.15 0.20 0.25 0.30 0.40 0.50 0.20 0.25 0.30 0.35 0.40 0.45 20-24 22-27 24-29 25-30 27-33 28-35 30-37 32-39 25-33 27-35 29-37 32-40 34-42 36-44 0.11 0.13 0.17 0.20 0.25 0.31 0.37 0.43 0.17 0.18 0.21 0.24 0.27 0.30 17-25 18-26 19-26 20-28 21-29 22-29 22-30 23-31 22-29 22-30 24-33 26-35 28-37 30-39 † Pressure drop data are approximate values to allow for use in all design conditions. ‡ The distance the air from the grille travels from the diffuser before it slows down to 50 ft. per minute. All sides open. 21 22 23 For complete catalog information including submittals, energy calculations, dimension drawings, and more go to www.ReznorHVAC.com or call 800-695-1901. © 2015 Reznor LLC. Reznor is registered in at least the United States. All other trademarks are the property of their respective owners. All rights Reserved. Printed in U.S.A. 268E-0315 Form S-R6GP Note: In keeping with our policy of continuous product improvement, we reserve the right to alter, at any time, the design, construction, dimensions, weights, etc., of equipment information shown here.