Preview only show first 10 pages with watermark. For full document please download

Radiatore In Alluminio Jet Ecoplus

   EMBED


Share

Transcript

jet ecoplus High pressure altezza height (mm) B JET ECOPLUS 100 W2 500 JET ECOPLUS 100 W3 350 JET ECOPLUS 100 W3 500 JET ECOPLUS 100 W3 600 JET ECOPLUS 100 W3 700 JET ECOPLUS 100 W3 800 565 417 563 667 762 864 interasse profondità larghezza H2O peso water width thickness centres weight capacity (mm) (mm) (mm) (kg) (lt) A C D 500 350 500 600 700 800 96 96 96 96 96 96 80 80 80 80 80 80 0,31 0,25 0,31 0,36 0,38 0,42 1,34 1,04 1,42 1,56 1,71 1,92 pressione resa termica ∆T 50 esercizio thermal power operative pressure (W) (kcal/h) (bar) 16 112 96 16 87 75 16 116 100 16 134 115 16 153 132 16 175 151 n Km 1,3136 1,2971 1,3184 1,3176 - 0,6554 0,5441 0,6684 0,7748 - Equazione caratteristica: φ=Km∆tn. Valori di potenza termica stimati presso il Politecnico di Milano secondo la norma EN442. Per un corretto funzionamento del radiatore è consigliabile l’uso di una valvola di sfiato aria e di non isolare mai la batteria dall’impianto, chiudendone le valvole. Ricordiamo inoltre che la garanzia è valida per una pressione massima di esercizio di 16 bar e una temperatura massima d’esercizio di 120°. Mozzo Ø: 1”. Characteristic Equation: φ=Km∆tn. Thermal power values estimated at the Milan Polytechnic in accordance with the EN442 norm. In order for the radiator to function correctly, it is recommended that you use an automatic valve with an air vent and that you never isolate the battery from the installation by closing its valves. Also remember that the guarantee is valid as long as the installations working preassure does not exceed 16 bar. Maximum working temperature: 120°. Hub Ø: 1” Bassa temperatura / Low temperature ∆T 25 26 27 28 29 30 31 32 33 34 35 36 37 38 Coef. 0,403 0,424 0,446 0,467 0,489 0,512 0,534 0,557 0,580 0,603 0,626 0,650 0,674 0,698 ∆T 39 40 41 42 43 44 45 46 47 48 49 50 51 52 Coef. 0,722 0,746 0,771 0,796 0,821 0,846 0,871 0,896 0,922 0,948 0,974 1,000 1,026 1,053 ∆T 53 54 55 56 57 58 59 60 61 62 63 64 65 66 Coef. 1,079 1,106 1,133 1,160 1,188 1,215 1,242 1,270 1,298 1,326 1,354 1,382 1,411 1,439 ∆T 67 68 69 70 71 72 73 74 75 76 77 78 79 80 Coef. 1,468 1,497 1,526 1,555 1,584 1,613 1,643 1,672 1,702 1,732 1,762 1,792 1,822 1,852 jet ecoplus Informazioni tecniche / Technical informations Indicazioni per il montaggio / Assembly instructions C A Mensola Bracket Valvola di sfiato Air vent Tappo Plug L H ix Connessioni / Joints i 150 mm * Applicazione consigliata / recommended application L = A x n° elementi / A x no. elements i = L + 90 mm (standard) 9