Radium Minibay Configured System Level Schematics Advisory

   EMBED


Share

Transcript

REVISIONS LTR DESCRIPTION ENGR DJ DWN CHK DJ FT FT A ECO 06-648 RELEASED B ECO 06-826 ADD NOTE 3 & SHEET 12 (JAMACA,BARBADOS) DJ DJ C ECO 07-656 UPDATE SURGE PROTECTOR WIRING OPTIONS DJ DJ DATE APVD 5-15-06 DM 10-9-06 DM 5-24-07 PRIMARY ENCLOSURE FLORESCENT LAMP 48VDC AIR CONDITIONER - DC FLORESCENT LAMP EVAP FANS Evap Temp Sensor J11 RMT A B C COMPRESSOR Remote Temp (+) MML (-) PWR (+) PWR (-) J12 1 2 MINOR MINOR MAJOR MAJOR J10 1 2 3 4 DOOR SW DOOR SW L2 L1 N METER BASE LOCAL PWR (+) PWR (-) 18C 23C SHDOWN ALARM 28C 33C 38C NC NC SETPOINT MINOR N0 MAJOR N0 SPEED CONTROL BOARD AIR COND TEMP CONTROL Evap temp COND FANS J1 Cond Temp Sensor METER L2 N 875-055-20 HOT LOAD N -48VDC POSITIVE GND SYSTEM BLACK (-) HOT RED (+) COMMON LIGHT RECPT 2 N HOT G BBX 8 CKT LOAD CENTER L1 1 L2 2 60A 3 4 5 15A 6 7 8 30A NEUT GND PCBA - ALARM CROSS CONNECT 1 2 3 2 4 5 3 6 7 4 8 9 5 10 11 6 12 13 7 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 COOLING SYSTEM MAJOR 24 48 49 COOLING SYSTEM MINOR 25 50 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 COM HOT Customer Provided Hook up for meter 20A GFCI OUTLET LINE G Gnd Bshg HOT L1 N 875-089-20 1 Model RMB-48 with options: 1 Enclosure with one 48VDC Air Cond Door 100A AC Service Load Center 8-position (External Mount) Surge Protector 3W+G 30A Max CB Limited GFCI outlets AC Lights Alarm Terminal Board Enclosure Intrusion Sensors 875-071-20 ML2 ML2 Isolated Bus Bar Line 1 Line 2 Neutral GND SURGE PROTECTOR 30A MAX CB LIMITED 3W+G ENCL GROUNDBAR 1 875-125-20 3. SYSTEMS WITH 1KW OR 1.8KW CORDEX RECTIFIER OPTIONS MAY REQUIRE AC GENERATOR INLET, TYPE IEC 309-2 WITH 60AMP MINIMUM BREAKER SIZE IF SYSTEM LOAD IS GREATER THEN 5KW. 2. WHEN A SEALED MINIBAY EQUIPMENT ENCLOSURE IS USED TO HOUSE BATTERY PACKS, BATTERIES MUST BE VALVE REGULATED AND PROVITIONS SHOULD BE MADE FOR ADIQUIT HYDROGEN VENTING. 1. EARTH GROUND TO CUSTOMER INSTALLED GROUND RING LENGTH OF WIRES CAN BE CUT TO FIT IF REQUIRED. REMAKE TERMINATE USING THE SAME ALPHA WORKMANSHIP & PARTS. NOTE: UNLESS SPECIFIED OTHERWISE DRAWN D. JOHNSTON 5-15-06 CHK F. TARI 6-21-06 ENGR D. JOHNSTON 5-15-06 MANUF B. GRIFFITH 6-29-06 Q.A. D. MATTS 6-29-06 PLOTTED ON: 25-May-2007 14:52:06 ALPHA TECHNOLOGIES TITLE: SCHEMATIC RADIUM MINI SYSTEM ISSUED DATE: DRAWING NO: REV: 044-001-05 FILE REF: 04400105___C__W01.SCH SIZE: D SHEET C 1 OF 12 PRIMARY SIDE CHAMBER PRIMARY ENCLOSURE FLORESCENT LAMP FLORESCENT LAMP AIR CONDITIONER - DC FLORESCENT LAMP A B C COMPRESSOR Remote Temp RMT PWR (+) PWR (-) J11 (+) MML (-) SETPOINT 1 J12 PWR (+) 2 PWR (-) 1 J10 MINOR 2 MINOR 3 MAJOR 4 MAJOR DOOR SW LOCAL J1 18C 23C SHDOWN ALARM 28C 33C 38C NC NC MINOR N0 MAJOR N0 Evap temp SPEED CONTROL BOARD AIR COND TEMP CONTROL TAMPER DOOR SW DOOR SW EVAP FANS Evap Temp Sensor COND FANS L2 L1 N 875-089-20 HOT LOAD N 1 Enclosure with one 48VDC Air Cond Door 1 Side Chamber 1 RSM 48/10 FUSE MODULE E1/2 2 E3/4 3 LVD Gnd Bshg TB2 HOT - B LVD TB3 COMMON - A LIGHT RECPT 2 N 4 TB1 HOT - A 5 TB4 COMMON - B 6 HOT 7 RIBBON 1-16 8 9 G 10 11 BBX 8 CKT LOAD CENTER L1 12 1 60A 30A 4 1 2 E2 5 20A 6 L1 L2 GND L1 L2 GND OUTPUT (-) Module 1 OUTPUT (+) TB2 Gnd N L2 L1 ENCL GROUNDBAR 1 875-125-20 Line 1 Line 2 GND GEN INLET 1 2 3 4 5 6 11 16 E7 1ALM 2ALM 31 2 P7 MJR P8 MNR P9 ACF ALM 1 C ALM 1 ALM 2 C TB 3 ALM 2 TB4 TS COM TS 1 TS 2 75A 1 2 3 4 RSM 48/10 - 19" CABINET RSM 48/10 -3 W/O SUPI COMMON AUX -48v RSM 48/10 SUPI NC LVD NC LVD C LVD B FU/BRKR FUSE ALM B FU/BRKR C 16 POS. RIBBON CABLE BRKR ALM LVA 1ALM 2ALM 32 1 FUSE ALM A P8 EXMJR LVA C P9 EXMNR NC HVA HVA C P10 LVD RSM MAJOR MINOR P11 LVA RSM MINOR MINOR C P12 HVA HV ALARM MAJOR P13 SUPI AC FAIL MAJOR C P14 FU/BR SUP'Y FAIL AC FAIL LV ALARM AC FAIL C SLAVE IN LVD A COMMON RIBBON 1-16 RIBBON 1-16 RSM 48/10 RLY ALM MDL -002 NEUT GND 15 14 13 12 10 9 8 7 WATER INTRUSION 15 874-978-20 Module 3 8 1 2 3 E8 Module 2 15A 7 SURGE PROTECTOR 2W+G 14 TB1 75A 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 TAMPER 1 2 E1 875-054-20 3 TAMPER 16 AC FAIL 17 RECT. MAJOR 18 RECT. MINOR 19 HVA 20 LVA 21 FUSE/BREAKER 22 BAT COMPARTMENT FAN 23 COOLING SYSTEM MAJOR 24 COOLING SYSTEM MINOR 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 EUSERC Meter w/60A FBX 12-position distribution Surge Protector 2W+G AC Gen Inlet GFCI outlets Battery Heater Mat AC Lights RSM 48/10 3 Modual Rectifier Shelf (W/GMT Fuse Dist) Alarm Terminal Board Enclosure Intrusion Sensors Water Intrusion Sensor 875-063-20 TAMPER 2 875-110-20 L2 13 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Isolated Bus Bar 60A N G 1 Battery Storage Unit PCBA - ALARM CROSS CONNECT COM 875-258-20 FUSE DISCONNECT 875-055-20 875-056-20 Model RMB-48 with options: HOT L1 Gnd Bshg HOT G N L2 HOT LIGHT RECPT 2 N 20A GFCI OUTLET LINE G METER N USERC METER BASE Cond Temp Sensor 874-933-21 3. SYSTEMS WITH 1KW OR 1.8KW CORDEX RECTIFIER OPTIONS MAY REQUIRE AC GENERATOR INLET, TYPE IEC 309-2 WITH 60AMP MINIMUM BREAKER SIZE IF SYSTEM LOAD IS GREATER THEN 5KW. 875-063-22 875-068-20 75A 875-071-20 TAMPER 100A 12V BATTERY 12V BATTERY 12V BATTERY 875-064-20 875-059-20 875-110-20 TEMP SENSE 12V BATTERY ML2 TAMPER 1 2 1 2 PWR (+) PWR (-) PWR (+) PWR (-) Fan1 (+) Fan1 (-) J2 J1 CL = ALM C J3OP = ALM J4 1 2 3 4 1 2 3 (+) (-) DC FAN Battery Compartment Fan TRAY GROUND ML2 EARTH GROUND TO CUSTOMER INSTALLED GROUND RING 1. BATT HEATER FLOAT SW 2. WHEN A SEALED MINIBAY EQUIPMENT ENCLOSURE IS USED TO HOUSE BATTERY PACKS, BATTERIES MUST BE VALVE REGULATED AND PROVITIONS SHOULD BE MADE FOR ADIQUIT HYDROGEN VENTING. BATTERY STORAGE UNIT LENGTH OF WIRES CAN BE CUT TO FIT IF REQUIRED. REMAKE TERMINATE USING THE SAME ALPHA WORKMANSHIP & PARTS. NOTE: UNLESS SPECIFIED OTHERWISE DRAWN D. JOHNSTON 5-15-06 D. JOHNSTON 5-15-06 CHK ENGR ALPHA TECHNOLOGIES MANUF Q.A. PLOTTED ON: TITLE: 25-May-2007 14:27:35 SCHEMATIC RADIUM MINIBAY SYSTEM ISSUED DATE: DRAWING NO: REV: 044-001-05 FILE REF: 04400105___C__W02.SCH SIZE: D SHEET C 2 OF 12 PRIMARY ENCLOSURE FLORESCENT LAMP AIR CONDITIONER - DC FLORESCENT LAMP EVAP FANS Evap Temp Sensor A B C COMPRESSOR J1 (+) MML (-) RMT PWR (+) PWR (-) Remote Temp LOCAL J11 1 J12 PWR (+) 2 PWR (-) 1 J10 MINOR 2 MINOR 3 MAJOR 4 MAJOR DOOR SW DOOR SW L2 L1 N METER BASE SETPOINT 18C 23C SHDOWN ALARM 28C 33C 38C NC NC MINOR N0 MAJOR N0 SPEED CONTROL BOARD AIR COND TEMP CONTROL Evap temp COND FANS Cond Temp Sensor METER L2 (+) (-) N N Model RMB-48 with options: 75A BATT 100A COM 1 2 3 4 LVD LIGHT RECPT 2 N 20A 20A 20A 20A HOT 875-332-20 OUT 5 CB1 CB2 CB3 CB4 6 7 RIBBON 1-16 RSM 48/10 BREAKER MODULE 8 9 G 10 11 BBX 8 CKT LOAD CENTER L1 12 1 13 60A 1 2 E2 15A 6 L1 L2 GND TB1 OUTPUT (-) Module 1 OUTPUT (+) TB2 E8 WATER INTRUSION 15 E7 874-978-20 Module 2 7 1ALM 2ALM 31 2 P7 MJR P8 MNR P9 ACF Module 3 8 NEUT 75A 15 14 13 12 10 9 8 7 875-125-20 ENCL GROUNDBAR 1 Line 1 Line 2 GND Neutral SURGE PROTECTOR 3W+G 1 2 3 4 5 6 11 16 TS COM TS 1 TS 2 1 2 3 4 RSM 48/10 - 19" CABINET RSM 48/10 -3 W/O SUPI COMMON AUX -48v RSM 48/10 SUPI NC LVD NC LVD C LVD B FU/BRKR FUSE ALM B FU/BRKR C 16 POS. RIBBON CABLE BRKR ALM LVA 1ALM 2ALM 32 1 FUSE ALM A P8 EXMJR LVA C P9 EXMNR NC HVA HVA C P10 LVD RSM MAJOR MINOR P11 LVA RSM MINOR MINOR C P12 HVA HV ALARM MAJOR P13 SUPI AC FAIL MAJOR C P14 FU/BR SUP'Y FAIL AC FAIL LV ALARM AC FAIL C SLAVE IN LVD A COMMON RIBBON 1-16 RIBBON 1-16 RSM 48/10 RLY ALM MDL -002 GND 1 2 3 ALM 1 C ALM 1 ALM 2 C TB 3 ALM 2 TB4 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 TAMPER 16 AC FAIL 17 RECT. MAJOR 18 RECT. MINOR 19 HVA 20 LVA 21 FUSE/BREAKER 22 BAT COMPARTMENT FAN 23 COOLING SYSTEM MAJOR 24 COOLING SYSTEM MINOR 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 1 Battery Storage Unit 100A AC Service Load Center 8-position (External Mount) Surge Protector 3W+G GFCI outlets AC Lights RSM 48/10 3 Modual Rectifier Shelf (Circuit Breaker Distribution) Alarm Terminal Board Enclosure Intrusion Sensors Water Intrusion Sensor NetCom SNMP Alarm Monitor WHT GRN RED YEL BLU 875-063-20 BLK HOT 5 20A L1 L2 GND 14 TAMPER 4 1 2 E1 875-054-20 3 R? TAMPER 2 875-110-20 L2 1 Enclosure with one 48VDC Air Cond Door PCBA - ALARM CROSS CONNECT 875-241-20 875-055-20 HOT LOAD RS 232 Isolated Bus Bar HOT Customer Provided Hook up for meter NetCOM SNMP Alarm Monitor 20A GFCI OUTLET LINE G Gnd Bshg COM L1 N 875-089-20 3. SYSTEMS WITH 1KW OR 1.8KW CORDEX RECTIFIER OPTIONS MAY REQUIRE AC GENERATOR INLET, TYPE IEC 309-2 WITH 60AMP MINIMUM BREAKER SIZE IF SYSTEM LOAD IS GREATER THEN 5KW. 874-933-21 875-068-20 75A 75A 875-071-20 100A 12V BATTERY ML2 12V BATTERY 875-064-20 875-110-20 TEMP SENSE 875-059-20 12V BATTERY 2. WHEN A SEALED MINIBAY EQUIPMENT ENCLOSURE IS USED TO HOUSE BATTERY PACKS, BATTERIES MUST BE VALVE REGULATED AND PROVITIONS SHOULD BE MADE FOR ADIQUIT HYDROGEN VENTING. TAMPER 12V BATTERY TAMPER 1 2 1 2 PWR (+) PWR (-) PWR (+) PWR (-) Fan1 (+) Fan1 (-) J2 J1 CL = ALM C J3OP = ALM J4 1 2 3 4 1 2 3 (+) (-) DC FAN 1. Battery Compartment Fan TRAY GROUND ML2 EARTH GROUND TO CUSTOMER INSTALLED GROUND RING FLOAT SW BATTERY STORAGE UNIT LENGTH OF WIRES CAN BE CUT TO FIT IF REQUIRED. REMAKE TERMINATE USING THE SAME ALPHA WORKMANSHIP & PARTS. NOTE: UNLESS SPECIFIED OTHERWISE DRAWN D. JOHNSTON 5-15-06 D. JOHNSTON 5-15-06 CHK ENGR ALPHA TECHNOLOGIES MANUF Q.A. PLOTTED ON: TITLE: 25-May-2007 14:29:33 SCHEMATIC RADIUM MINI BAY SYSTEM ISSUED DATE: DRAWING NO: REV: 044-001-05 FILE REF: 04400105___C__W03.SCH SIZE: D SHEET C 3 OF 12 PRIMARY SIDE CHAMBER PRIMARY ENCLOSURE FLORESCENT LAMP FLORESCENT LAMP AIR CONDITIONER - DC FLORESCENT LAMP COMPRESSOR A B C PWR (+) PWR (-) Remote Temp RMT J1 J11 (+) MML (-) SETPOINT 1 J12 PWR (+) 2 PWR (-) LOCAL COND FANS Cond Temp Sensor METER HOT LOAD 1 Enclosure with one 48VDC Air Cond Coor N 1 Side Chamber COMMNET 10 GMT PANEL RECT (-) RECT (+) GMT1 GMT2 GMT3 G 1 GMT4 2 GMT5 875-056-20 3 GMT6 875-109-21 N 5 GMT8 6 GMT9 7 GMT10 8 9 G BBX 8 CKT LOAD CENTER L1 HOT 4 GMT7 NO Fuse Fail COM NC LIGHT RECPT 2 10 1 L2 11 60A 2 12 3 13 30A 20A 1 2 E2 15A L1 L2 GND Module 1 OUTPUT (+) TB2 Gnd N L2 L1 875-125-21 ENCL GROUNDBAR 1 875-125-20 GEN INLET 1 2 3 4 5 6 11 16 ALM 1 C ALM 1 ALM 2 C TB 3 ALM 2 TB4 TS COM TS 1 TS 2 COMMON NC NC LVD B FUSE ALM B BRKR ALM FUSE ALM A NC RSM MAJOR RSM MINOR HV ALARM AC FAIL SUP'Y FAIL LV ALARM LVD A COMMON Module 5 1 2 3 4 RSM 48/10 - 23" CABINET RSM 48/10 SUPI AUX -48v LVD LVD C FU/BRKR FU/BRKR C LVA LVA C HVA HVA C MINOR MINOR C MAJOR MAJOR C AC FAIL AC FAIL C RSM 48/10 RLY ALM MDL -002 GND Line 1 Line 2 Neutral GND SURGE PROTECTOR 3W+G E7 16 POS. RIBBON CABLE 1ALM 2ALM 32 1 P8 EXMJR P9 EXMNR P10 LVD P11 LVA P12 HVA P13 SUPI P14 FU/BR SLAVE IN 875-108-20 Module 4 15 14 13 12 10 9 8 7 WATER INTRUSION 15 1ALM 2ALM 31 2 P7 MJR P8 MNR P9 ACF Module 3 1 2 3 E8 Module 2 NEUT 8 OUTPUT (-) 15 14 13 12 11 874-978-20 10 9 8 7 6 5 4 3 2 1 TAMPER 16 AC FAIL 17 RECT. MAJOR 18 RECT. MINOR 19 HVA 20 LVA 21 FUSE/BREAKER 22 BAT COMPARTMENT FAN 23 COOLING SYSTEM MAJOR 24 COOLING SYSTEM MINOR 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 875-110-20 MAIN GROUNDBAR - SIDE CHAMBER 875-071-20 875-059-20 TEMP SENSE 12V BATTERY 12V BATTERY TAMPER 12V BATTERY ML2 TAMPER 1 2 1 2 PWR (+) PWR (-) PWR (+) PWR (-) Fan1 (+) Fan1 (-) J2 J1 CL = ALM C J3OP = ALM J4 1 2 3 4 1 2 3 (+) (-) DC FAN Battery Compartment Fan ML2 TRAY GROUND EARTH GROUND GFCI Outlets Battery heater Mats AC Lights RSM 48/10 5 Modual Rectifier Shelf ComNet 10 GMT Fuse Panel 50amp Alarm Terminal Board Enclosure Intrusion Sensors Water Intrusion Sensor SYSTEMS WITH 1KW OR 1.8KW CORDEX RECTIFIER OPTIONS MAY REQUIRE AC GENERATOR INLET, TYPE IEC 309-2 WITH 60AMP MINIMUM BREAKER SIZE IF SYSTEM LOAD IS GREATER THEN 5KW. 2. WHEN A SEALED MINIBAY EQUIPMENT ENCLOSURE IS USED TO HOUSE BATTERY PACKS, BATTERIES MUST BE VALVE REGULATED AND PROVITIONS SHOULD BE MADE FOR ADIQUIT HYDROGEN VENTING. 1. BATT HEATER FLOAT SW TO CUSTOMER INSTALLED GROUND RING AC Gen Inlet 3. 75A ANDERSON 12V BATTERY Surge Protector 3W+G RIBBON 1-16 RIBBON 1-16 874-933-21 100A 100A AC Service Load Center 8-position 875-063-20 875-068-20 7 14 TB1 875-064-20 6 L1 L2 GND TAMPER 1 2 E1 TAMPER 875-054-20 5 875-063-21 4 1 Battery Storage Unit PCBA - ALARM CROSS CONNECT COM Customer Provided Hook up for Meter 875-055-20 HOT Model RMB-48 with options: N HOT LIGHT RECPT 2 20A GFCI OUTLET LINE G HOT L2 L1 N 875-089-20 Gnd Bshg N 1 J10 MINOR 2 MINOR 3 MAJOR 4 MAJOR DOOR SW DOOR SW L2 L1 N 18C 23C SHDOWN ALARM 28C 33C 38C NC NC MINOR N0 MAJOR N0 Evap temp SPEED CONTROL BOARD AIR COND TEMP CONTROL TAMPER USERC METER BASE DOOR SW EVAP FANS Evap Temp Sensor BATTERY STORAGE UNIT LENGTH OF WIRES CAN BE CUT TO FIT IF REQUIRED. REMAKE TERMINATE USING THE SAME ALPHA WORKMANSHIP & PARTS. NOTE: UNLESS SPECIFIED OTHERWISE DRAWN D. JOHNSTON 5-15-06 D. JOHNSTON 5-15-06 CHK ENGR ALPHA TECHNOLOGIES MANUF Q.A. PLOTTED ON: TITLE: 25-May-2007 14:30:23 SCHEMATIC RADIUM MINIBAY SYSTEM ISSUED DATE: DRAWING NO: REV: 044-001-05 FILE REF: 04400105___C__W04.SCH SIZE: D SHEET C 4 OF 12 PRIMARY ENCLOSURE FLORESCENT LAMP FLORESCENT LAMP (+) (-) 875-060-20 FAN CONTROL - 2 -48v COM TACH PWM -48v COM TACH PWM -48v COM MAJOR MAJOR MINOR MINOR P5 - MML9 5 8 9 6 3 2 7 4 1 DC FAN P2 - MML2 2 1 CL = ALM C J3OP = ALM J4 COM -48v (+) (-) 1 2 3 P3- MML6 P1 - ML2 1 2 DOOR SW PWR (+) PWR (-) Model RMB-48 with options: (1) Enclosure with one 48VDC Fan Filter Door Or (1) Enclosure with one 48VDC Heat Exchanger Door 2 E3/4 3 4 LVD TB3 COMMON - A 5 TB4 COMMON - B 6 HOT 7 RIBBON 1-16 8 9 G 10 11 BBX 8 CKT LOAD CENTER 12 1 13 60A 875-054-20 3 30A 4 1 2 E2 5 20A 6 1 2 E1 L1 L2 GND L1 L2 GND TB1 OUTPUT (-) Module 1 OUTPUT (+) TB2 E8 WATER INTRUSION 15 E7 16 AC FAIL 17 RECT. MAJOR 18 RECT. MINOR 19 HVA 20 LVA 21 FUSE/BREAKER 22 BAT COMPARTMENT FAN 23 COOLING SYSTEM MAJOR 24 COOLING SYSTEM MINOR 25 75A 1ALM 2ALM 31 2 P7 MJR P8 MNR P9 ACF Module 3 8 TAMPER 874-978-20 Module 2 15A 7 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 TAMPER TS COM TS 1 TS 2 RSM 48/10 - 19" CABINET RSM 48/10 -3 W/O SUPI COMMON AUX -48v RSM 48/10 SUPI NC LVD NC LVD C LVD B FU/BRKR FUSE ALM B FU/BRKR C 16 POS. RIBBON CABLE BRKR ALM LVA 1ALM 2ALM 32 1 FUSE ALM A P8 EXMJR LVA C P9 EXMNR NC HVA HVA C P10 LVD RSM MAJOR MINOR P11 LVA RSM MINOR MINOR C P12 HVA HV ALARM MAJOR P13 SUPI AC FAIL MAJOR C P14 FU/BR SUP'Y FAIL AC FAIL LV ALARM AC FAIL C SLAVE IN LVD A COMMON RIBBON 1-16 RIBBON 1-16 874-933-21 Surge Protector 3W+G AC Gen Inlet GFCI outlets Battery Heater Mat AC Lights RSM 48/10 3 Modual Rectifier Shelf (W/GMT Fuse Distribution) Alarm Terminal Board Enclosure Intrusion Sensors Water Intrusion Sensor TAMPER 100A 12V BATTERY 12V BATTERY 875-064-20 875-059-20 875-110-20 TEMP SENSE 875-108-20 875-071-20 3. SYSTEMS WITH 1KW OR 1.8KW CORDEX RECTIFIER OPTIONS MAY REQUIRE AC GENERATOR INLET, TYPE IEC 309-2 WITH 60AMP MINIMUM BREAKER SIZE IF SYSTEM LOAD IS GREATER THEN 5KW. 875-068-20 875-063-21 75A 75A 12V BATTERY 100A AC Service Load Center 8-position 875-063-20 TAMPER GEN INLET 1 2 3 4 5 6 11 16 ENCL GROUNDBAR 1 875-125-20 Gnd N L2 L1 15 14 13 12 10 9 8 7 1 2 3 4 875-110-20 1 2 3 ALM 1 C ALM 1 ALM 2 C TB 3 ALM 2 TB4 RSM 48/10 RLY ALM MDL -002 NEUT 75A GND Line 1 Line 2 GND Neutral SURGE PROTECTOR 3W+G 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Isolated Bus Bar LVD TB2 HOT - B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 COM 1 RSM 48/10 FUSE MODULE E1/2 TB1 HOT - A (2) Battery Storage Units R? PCBA - ALARM CROSS CONNECT 875-404-20 HOT 5A N 2 PWM TACH (+) -48v N Customer Provided Hook up for meter 875-055-20 HOT LOAD LIGHT RECPT 2 L2 PWM TACH (+) -48v L2 L1 Gnd Bshg L1 APW 48VDC HEAT EXCHANGER 5A FUSE N HOT YEL BLU RED BLK YEL BLU RED BLK GFCI OUTLET LINE G METER N 1 2 PWR (+) PWR (-) DC FAN FAN CONTROL (Heat Exchanger) L2 N L1 DOOR SW 1 2 1 2 3 4 Fan1 (+) Fan1 (-) Fan2 (+) J2 J1 Fan2 (-) DC HEAT EXCHANGER Cooling Option APW HEAT EXCH TEMP CONTL TSTAT 6 3 4 1 2 5 Fan-Filtered Cooling Option 12V BATTERY ML2 TAMPER 1 2 1 2 PWR (+) PWR (-) PWR (+) PWR (-) Fan1 (+) Fan1 (-) J2 J1 CL = ALM C J3OP = ALM J4 1 2 3 4 1 2 3 (+) (-) DC FAN 2. WHEN A SEALED MINIBAY EQUIPMENT ENCLOSURE IS USED TO HOUSE BATTERY PACKS, BATTERIES MUST BE VALVE REGULATED AND PROVITIONS SHOULD BE MADE FOR ADIQUIT HYDROGEN VENTING. Battery Compartment Fan TRAY GROUND EARTH GROUND 75A 1ST BATTERY STORAGE UNIT 75A TAMPER 875-110-20 TEMP SENSE 12V BATTERY 12V BATTERY DRAWN 12V BATTERY ML2 ENGR TRAY GROUND BATT HEATER FLOAT SW 5-15-06 D. JOHNSTON 5-15-06 ALPHA TECHNOLOGIES MANUF TAMPER Q.A. PLOTTED ON: 875-059-20 D. JOHNSTON CHK 875-064-20 12V BATTERY LENGTH OF WIRES CAN BE CUT TO FIT IF REQUIRED. REMAKE TERMINATE USING THE SAME ALPHA WORKMANSHIP & PARTS. NOTE: UNLESS SPECIFIED OTHERWISE TO CUSTOMER INSTALLED GROUND RING 100A 1. 875-063-21 BATT HEATER 2ND BATTERY STORAGE UNIT TITLE: 25-May-2007 14:31:09 SCHEMATIC RADIUM MINIBAY SYSTEM ISSUED DATE: DRAWING NO: REV: 044-001-05 FILE REF: 04400105___C__W05.SCH SIZE: D SHEET C 5 OF 12 PRIMARY SIDE CHAMBER PRIMARY ENCLOSURE FLORESCENT LAMP SECONDARY SIDE CHAMBER SECONDARY ENCLOSURE FLORESCENT LAMP FLORESCENT LAMP FLORESCENT LAMP AIR CONDITIONER - DC FLORESCENT LAMP Evap Temp Sensor COMMNET CDM 75A 1 3 4 ALARM 6 GMT7 HOT 7 GMT8 8 9 875-109-20 10 12 13 OUTPUT (+) TB2 9 11 875-125-20 GND 875-125-21 ENCL GROUNDBAR 1 Neutral ALM 1 C ALM 1 ALM 2 C TB 3 ALM 2 TB4 TS COM TS 1 TS 2 COMMON NC NC LVD B FUSE ALM B BRKR ALM FUSE ALM A NC RSM MAJOR RSM MINOR HV ALARM AC FAIL SUP'Y FAIL LV ALARM LVD A COMMON Module 5 75A 1 2 3 4 RSM 48/10 - 23" CABINET RSM 48/10 SUPI 16 POS. RIBBON CABLE 1ALM 2ALM 32 1 P8 EXMJR P9 EXMNR P10 LVD P11 LVA P12 HVA P13 SUPI P14 FU/BR SLAVE IN 75A 15 14 13 12 874-978-20 11 10 9 8 7 6 5 4 3 2 1 AUX -48v LVD LVD C FU/BRKR FU/BRKR C LVA LVA C HVA HVA C MINOR MINOR C MAJOR MAJOR C AC FAIL AC FAIL C RSM 48/10 RLY ALM MDL -002 NEUT GND Line 1 Line 2 1 2 3 4 5 6 11 16 E7 875-108-20 Module 4 12 15 14 13 12 10 9 8 7 WATER INTRUSION 15 1ALM 2ALM 31 2 P7 MJR P8 MNR P9 ACF Module 3 1 2 3 E8 Module 2 10 TAMPER 16 AC FAIL 17 RECT. MAJOR 18 RECT. MINOR 19 HVA 20 LVA 21 FUSE/BREAKER 22 BAT COMPARTMENT FAN 23 COOLING SYSTEM MAJOR 24 COOLING SYSTEM MINOR 25 COMPRESSOR J1 PWR (+) PWR (-) Remote Temp (+) MML (-) J11 1 2 HOT LOAD 3 N 4 5 6 7 8 9 LIGHT RECPT 2 N 10 HOT 11 12 13 G 14 875-056-20 15 TAMPER 16 17 18 19 20 21 22 23 BAT COMPARTMENT FAN 24 COOLING SYSTEM MAJOR 25 COOLING SYSTEM MINOR 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Battery heater Mats AC Lights RSM 48/10 5 Modual Rectifier Shelf KTK Panel Distribution 2 Alarm Terminal Boards Enclosure Intrusion Sensors Water Intrusion Sensor 875-063-20 TAMPER TAMPER RIBBON 1-16 RIBBON 1-16 875-110-20 TAMPER 75A 75A TEMP SENSE 12V BATTERY 12V BATTERY TAMPER 12V BATTERY ML2 TAMPER 1 2 1 2 PWR (+) PWR (-) PWR (+) PWR (-) Fan1 (+) Fan1 (-) J2 J1 CL = ALM C J3OP = ALM J4 Battery Compartment Fan TRAY GROUND ML2 EARTH GROUND 1 2 3 4 1 2 3 (+) (-) 1 2 3 4 (+) (-) 75A 875-110-20 875-110-20 875-059-20 875-071-20 FEED CURRENT LIMITED SURGE ARRESTOR TO CUSTOMER INSTALLED GROUND RING 875-125-23 875-059-20 MAIN GROUNDBAR - SIDE CHAMBER 875-125-22 12V BATTERY GFCI outlets 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 874-933-21 100A Surge Protector 3W+G 30A Max CB Limited R? PCBA - ALARM CROSS CONNECT N HOT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 HOT 15A L1 L2 GND OUTPUT (-) Module 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 875-068-20 8 1 2 E2 15A TB1 875-064-20 7 20A L1 L2 GND 875-063-21 6 1 2 E1 TAMPER 875-054-20 5 14 TAMPER Customer Provided Hook up for Generator Inlet EUSERC Meter w/60A FBX 12-position distribution G Battery Compartment Fan 1 2 3 Fan1 (+) Fan1 (-) J1 J2 PWR (+) PWR (-) CL = ALM PWR (+) C J3 J4 PWR (-) OP = ALM 1 2 1 2 100A TAMPER DC FAN 12V BATTERY 12V BATTERY ML2 12V BATTERY 1ST BATTERY STORAGE UNIT ML2 TAMPER TRAY GROUND 3. SYSTEMS WITH 1KW OR 1.8KW CORDEX RECTIFIER OPTIONS MAY REQUIRE AC GENERATOR INLET, TYPE IEC 309-2 WITH 60AMP MINIMUM BREAKER SIZE IF SYSTEM LOAD IS GREATER THEN 5KW. 2. WHEN A SEALED MINIBAY EQUIPMENT ENCLOSURE IS USED TO HOUSE BATTERY PACKS, BATTERIES MUST BE VALVE REGULATED AND PROVITIONS SHOULD BE MADE FOR ADIQUIT HYDROGEN VENTING. 12V BATTERY BATT HEATER FLOAT SW GROUNDBAR - SIDE CHAMBER 2 875-259-20 5 GMT6 11 4 30A 2 Battery Storage Units COM N 2 GMT3 60A 3 HOT 75A GMT1 1 2 Cond Temp Sensor GFCI OUTLET LINE G R? PCBA - ALARM CROSS CONNECT GMT5 L2 N COND FANS AC Gen Interlock (Customer provided feed) KTK2 GMT4 L1 2 Side Chambers LIGHT RECPT 2 KTK1 Gnd Bshg G 2 Enclosures with two 48VDC Air Cond Doors ML3 GMT2 BBX 12CKT LOAD CENTER A B C HOT BAT (-) BAT (+) 60A N RMT Model RMB-48 with options: 875-068-20 N LIGHT RECPT 2 1 J12 PWR (+) 2 PWR (-) 1 J10 MINOR 2 MINOR 3 MAJOR 4 MAJOR 875-055-21 RECT (-) RECT (+) G LOCAL 20A 875-110-20 HOT LOAD SETPOINT 18C 23C SHDOWN ALARM 28C 33C 38C NC NC MINOR N0 MAJOR N0 SPEED CONTROL BOARD AIR COND TEMP CONTROL Evap temp 875-089-20 875-071-20 HOT 875-353-20 ENCL GROUNDBAR 2 875-258-20 N ML2 COM L2 L1 N FUSE DISCONNECT 20A GFCI OUTLET LINE G 875-056-20 SURGE PROTECTOR 30A MAX CB LIMITED 3W+G DOOR SW DOOR SW COMPRESSOR Remote Temp PWR (+) PWR (-) J11 (+) MML (-) SETPOINT 1 J12 PWR (+) 2 PWR (-) 1 J10 MINOR 2 MINOR 3 MAJOR 4 MAJOR DOOR SW DOOR SW L2 L1 N COND FANS EVAP FANS Evap Temp Sensor 875-089-20 875-055-20 G A B C METER LIGHT RECPT 2 HOT RMT DOOR SW AIR CONDITIONER - DC Cond Temp Sensor Gnd Bshg N LOCAL J1 18C 23C SHDOWN ALARM 28C 33C 38C NC NC MINOR N0 MAJOR N0 Evap temp SPEED CONTROL BOARD AIR COND TEMP CONTROL TAMPER USERC METER BASE DOOR SW FLORESCENT LAMP EVAP FANS 1. BATT HEATER 2ND BATTERY STORAGE UNIT LENGTH OF WIRES CAN BE CUT TO FIT IF REQUIRED. REMAKE TERMINATE USING THE SAME ALPHA WORKMANSHIP & PARTS. NOTE: UNLESS SPECIFIED OTHERWISE DRAWN D. JOHNSTON 5-15-06 D. JOHNSTON 5-15-06 CHK ENGR ALPHA TECHNOLOGIES MANUF Q.A. PLOTTED ON: TITLE: 25-May-2007 14:32:01 SCHEMATIC RADIUM MINIBAY SYSTEM ISSUED DATE: DRAWING NO: REV: 044-001-05 FILE REF: 04400105___C__w06.SCH SIZE: D SHEET C 6 OF 12 PRIMARY ENCLOSURE AIR CONDITIONER - DC EVAP FANS AIR COND TEMP CONTROL TAMPER 20A PWR (+) PWR (-) CL = ALM C J3OP = ALM J4 FAN CONTROL - 2 875-089-20 HOT G (+) (-) DC FAN P1 - ML2 P2 - MML2 P5 - MML9 -48v COM TACH PWM -48v COM TACH PWM 1 2 3 DC FAN FAN CONTROL (Heat Exchanger) 5 8 9 6 3 2 7 4 1 1 2 PWR (+) PWR (-) Fan1 (+) Fan1 (-) Fan2 (+) J2 J1 Fan2 (-) P3- MML6 -48v COM 1 2 1 2 3 4 DC HEAT EXCHANGER Cooling Option APW HEAT EXCH TEMP CONTL TSTAT 2 1 COND FANS (+) (-) MAJOR MAJOR MINOR MINOR Fan-Filtered Cooling Option 6 3 4 1 2 5 COMPRESSOR PWR (+) PWR (-) Remote Temp J1 (+) MML (-) A B C Cond Temp Sensor N LIGHT RECPT 2 N RMT TAMPER 875-404-20 HOT LOAD LOCAL 875-060-20 HOT J11 N 1 J12 PWR (+) 2 PWR (-) 1 J10 MINOR 2 MINOR 3 MAJOR 4 MAJOR 875-055-20 GFCI OUTLET LINE G SETPOINT 18C 23C SHDOWN ALARM 28C 33C 38C NC NC MINOR N0 MAJOR N0 Evap temp COM -48v FLORESCENT LAMP SPEED CONTROL BOARD DOOR SW DOOR SW Evap Temp Sensor 1 2 FLORESCENT LAMP YEL BLU RED BLK YEL BLU RED BLK APW 48VDC HEAT EXCHANGER PWM TACH (+) -48v PWM TACH (+) -48v 5A FUSE 5A Model: RMB-48 650W Cordex with options: Customer Provided 240VAC 60Hz Input Power N L1 L2 GMT FUSE -48VDC A/B 10/10 (+) A L2 2 60A 3 4 20A TB3 HOT - B TB4 COMMON - B TB2 COMMON - A (+) B Fuse Fail A COM NC Fuse Fail B COM NC 875-589-20 1 (-) B 1st Encl GFCI L1 TB1 HOT - A 875-590-20 (-) A 240V- TB3 16 Encl TAMPER 5 17 6 7 15A 18 19 8 2 3 4 L1 L2 GND TB3 CAN OUT 5 COOLING SYS 1 MAJOR 24 6 COOLING SYS 1 MINOR 25 7 Module 2 Module 4 8 1 9 4 Module 650W Cordex Shelf with CB Dist and LVD GMT Fuse Panel 10A/10B, -48VDC 120VAC 60Hz GFCI outlets 120VAC 60Hz Lights Enclosure Intrusion Sensors Enclosure Alarm Terminal Board GRN GRN GRN GRN GRN 3 11 4 12 5 Cordex 48VCD 650w 4 Module Shelf 75A (OPTIONAL) 875-110-20 12V BATTERY 2. WHEN A SEALED MINIBAY EQUIPMENT ENCLOSURE IS USED TO HOUSE BATTERY PACKS, BATTERIES MUST BE VALVE REGULATED AND PROVITIONS SHOULD BE MADE FOR ADIQUIT HYDROGEN VENTING. 875-068-20 1 2 75A 875-071-20 875-059-20 100A 12V BATTERY RED 3. SYSTEMS WITH 1KW OR 1.8KW CORDEX RECTIFIER OPTIONS MAY REQUIRE AC GENERATOR INLET, TYPE IEC 309-2 WITH 60AMP MINIMUM BREAKER SIZE IF SYSTEM LOAD IS GREATER THEN 5KW. 875-110-20 75A 12V BATTERY Surge Protector 3W+G 30A Max CB Limited 2 10 -48VDC POSITIVE GND SYSTEM BLACK (-) HOT RED (+) COMMON 12V BATTERY 23 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 8-Space AC Load Center 875-108-20 SURGE PROTECTOR 30A MAX CB LIMITED 3W+G 22 BAT COMP FAN 75A GND ENCL GROUNDBAR 1 Neutral 21 Module 1 TB4 Module 3 Line 1 Line 2 T2 HOT 1 2 L1 L2 GND T1 75A GND V1 (-) LOAD 1 2 BBX 8 CKT LOAD CENTER D2 (-) BATT 50A 50A 20A 20A 875-588-20 15 16 17 18 19 20 21 2223 HOT 1 (+) COMMON NEUT 20 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 1 Battery Storage Unit COM GND Enclosure with 48VDC Air Cond Door PCBA - ALARM CROSS CONNECT GRN (Cabinet Alarm) GRN 1 1 1 2 2 3 3 2 4 4 5 5 3 6 6 7 7 BRN (GMT Fuse Option)4 GRN 8 8 9 9 5 10 10 11 11 6 12 12 13 13 7 14 14 15 15 8 16 16 17 17 9 GRN BAT COMP FAN 2 18 18 19 19 2E COOLING MAJOR 10 20 20 21 21 2E COOLING MINOR 11 22 22 23 23 GRN 2Encl TAMPER 12 24 24 25 25 13 26 26 27 27 14 28 28 29 29 GRN WATER INTR (option) 15 30 30 1 2 PWR (+) PWR (-) PWR (+) PWR (-) Fan1 (+) Fan1 (-) J2 J1 CL = ALM C J3OP = ALM J4 1 2 3 4 1 2 3 (+) (-) 1. DC FAN TAMPER Battery Compartment Fan ML2 TRAY GROUND TAMPER LENGTH OF WIRES CAN BE CUT TO FIT IF REQUIRED. REMAKE TERMINATE USING THE SAME ALPHA WORKMANSHIP & PARTS. NOTE: UNLESS SPECIFIED OTHERWISE DRAWN D. JOHNSTON 5-15-06 D. JOHNSTON 5-15-06 CHK ENGR BATTERY STORAGE UNIT ALPHA TECHNOLOGIES MANUF Q.A. PLOTTED ON: TITLE: 5-Jun-2007 11:07:55 SCHEMATIC RADIUM MINIBAY SYSTEM ISSUED DATE: REV: 044-001-05 EARTH GROUND TO CUSTOMER INSTALLED GROUND RING DRAWING NO: FILE REF: 04400105___C__W07.SCH SIZE: D SHEET C 7 OF 12 FLORESCENT LAMP PRIMARY SIDE CHAMBER PRIMARY ENCLOSURE AIR CONDITIONER - DC EVAP FANS Evap Temp Sensor N HOT HOT LOAD J1 TAMPER A B C COMPRESSOR Remote Temp (+) MML (-) TAMPER PWR (+) PWR (-) SETPOINT RMT J11 1 J10 MINOR 2 MINOR 3 MAJOR 4 MAJOR 875-055-20 GFCI OUTLET LINE G LOCAL SPEED CONTROL BOARD 18C 23C SHDOWN ALARM 28C 33C 38C NC NC MINOR N0 MAJOR N0 FLORESCENT LAMP 1 J12 PWR (+) 2 PWR (-) DOOR SW DOOR SW AIR COND TEMP CONTROL Evap temp COND FANS Cond Temp Sensor N AIR CONDITIONER - DC 20A EVAP FANS Evap Temp Sensor A B C COMPRESSOR RMT PWR (+) PWR (-) Remote Temp LOCAL J1 G J11 (+) MML (-) 875-089-20 1 J10 MINOR 2 MINOR 3 MAJOR 4 MAJOR HOT 1 J12 PWR (+) 2 PWR (-) N SETPOINT 18C 23C SHDOWN ALARM 28C 33C 38C NC NC MINOR N0 MAJOR N0 LIGHT RECPT 2 SPEED CONTROL BOARD AIR COND TEMP CONTROL Evap temp COND FANS Cond Temp Sensor 20A 875-089-20 Customer Provided 240VAC 60Hz Input Power N L1 L2 30A 5 15A NEUT 8 16 2 1 Encl TAMPER 17 ALM OUTPUT 1 ALM OUTPUT 2 ALM OUTPUT 3 ALM OUTPUT 4 ALM OUTPUT 5 ALM OUTPUT 6 ALM OUTPUT 7 ALM OUTPUT 8 ALM OUTPUT 0 (+) GND RETURN 18 19 20 21 22 GND 875-528-23 875-527-20 Cordex 48 1kw 6 Mod Bulk Shelf TB1 1 L1 2 L2 OUTPUT (-) Module 1 GND OUTPUT (+) TB2 1 L1 2 L2 Module 2 GND ENCL GROUNDBAR 1 BBX 8 CKT LOAD CENTER GND SURGE PROTECTOR 3W+G Module 4 Module 5 COOLING SYS 1 MINOR 25 E2 2 3 GEN INLET 4 -48VDC POSITIVE GND SYSTEM BLACK (-) HOT RED (+) COMMON 5 8-Space AC Load Center Surge Protector 3W+G 6 Module 1KW Cordex Shelf with Controller 584 DIST Panel with Load LVD, 16 BKR POS 120VAC 60Hz GFCI outlets 120VAC 60Hz Lights Enclosure Intrusion Sensors Enclosure Alarm Terminal Board GRN YEL RED YEL GRN RED YEL ORG BLU RED 3. SYSTEMS WITH 1KW OR 1.8KW CORDEX RECTIFIER OPTIONS MAY REQUIRE AC GENERATOR INLET, TYPE IEC 309-2 WITH 60AMP MINIMUM BREAKER SIZE IF SYSTEM LOAD IS GREATER THEN 5KW. 120A 12V BATTERY 12V BATTERY 875-110-21 12V BATTERY 2. WHEN A SEALED MINIBAY EQUIPMENT ENCLOSURE IS USED TO HOUSE BATTERY PACKS, BATTERIES MUST BE VALVE REGULATED AND PROVITIONS SHOULD BE MADE FOR ADIQUIT HYDROGEN VENTING. 875-068-20 125A 875-071-20 875-059-20 ENCL GROUNDBAR 1 24 1 Module 6 12V BATTERY COOLING SYS 1 MAJOR E1 120A Neutral Module 3 23 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 1 Battery Storage Unit CAN OUT Line 1 Line 2 BAT COMP FAN 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 HOT 7 30A RS232 Single Side Chamber 120A 6 240V - TB2 8 7 6 5 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 240V- TB1 RS485 175 A 4 NET CAN 1 Input (-) Input (+) 3 DIGITAL INPUTS (BREAKERS OPTIONAL) TEMP 2 (-) TEMP 2 (+) TEMP 1 (-) TEMP 1 (+) 60A D8 D8 D7 D7 D6 D6 D5 D5 D4 D4 D3 D3 D2 D2 D1 D1 2 (-) CHARGE L2 -48V BATTERY 1 100A 100A L1 584 PANEL 48V CXC LLVD 16CB R? 1st Encl GFCI 875-587-20 Enclosure with two 48VDC air cond doors COM GND Model: RMB-48, 1K CORDEX with options: PCBA - ALARM CROSS CONNECT GRN (Intrusion) GRN 1 1 1 RED RED(Cool MAJ 2 2 YEL (Cool Min) YEL 3 3 2 ORG (Cust MAJ) ORG 4 4 BLU (Cust Min) BLU 5 5 3 6 6 7 7 GRN (Jumper) 4 GRN 8 8 9 9 ORG (Jumper) 5 ORG 10 10 11 11 BLU (Jumper) 6 BLU 12 12 13 13 7 14 14 15 15 8 16 16 17 17 BAT COMP FAN 29 YEL 18 18 19 19 2E COOLING MAJOR 10 20 20 21 21 2E COOLING MINOR 11 22 22 23 23 2Encl TAMPER 12 GRN 24 24 25 25 COOLING SYS 2 MAJ 13 RED 26 26 27 27 YEL COOLING SYS 2 MIN 14 28 28 29 29 GRN WATER INTR (option) 15 30 30 1 2 1 2 PWR (+) PWR (-) PWR (+) PWR (-) Fan1 (+) Fan1 (-) J2 J1 CL = ALM C J3OP = ALM J4 1 2 3 4 1 2 3 (+) (-) 1. DC FAN TAMPER Battery Compartment Fan ML2 TRAY GROUND TAMPER NOTE: UNLESS SPECIFIED OTHERWISE DRAWN BATTERY STORAGE UNIT LENGTH OF WIRES CAN BE CUT TO FIT IF REQUIRED. REMAKE TERMINATE USING THE SAME ALPHA WORKMANSHIP & PARTS. D. JOHNSTON 5-15-06 D. JOHNSTON 5-15-06 CHK ENGR ALPHA TECHNOLOGIES MANUF Q.A. PLOTTED ON: TITLE: 25-May-2007 14:35:39 SCHEMATIC RADIUM MINIBAY SYSTME ISSUED DATE: REV: 044-001-05 EARTH GROUND TO CUSTOMER INSTALLED GROUND RING DRAWING NO: FILE REF: 04400105___C__W08.SCH SIZE: D SHEET C 8 OF 12 FLORESCENT LAMP PRIMARY SIDE CHAMBER PRIMARY ENCLOSURE AIR CONDITIONER - DC SECONDARY ENCLOSURE FLORESCENT LAMP EVAP FANS Evap Temp Sensor AIR CONDITIONER - DC N TAMPER COMPRESSOR PWR (+) PWR (-) COND FANS HOT AIR CONDITIONER - DC 20A COND FANS EVAP FANS Evap Temp Sensor 20A 875-353-20 A B C COMPRESSOR RMT PWR (+) PWR (-) LOCAL Remote Temp 875-353-20 (+) MML (-) 1 J10 MINOR 2 MINOR 3 MAJOR 4 MAJOR 875-089-20 J11 Cond Temp Sensor J1 18C 23C SHDOWN ALARM 28C 33C 38C NC NC MINOR N0 MAJOR N0 Evap temp SPEED CONTROL BOARD AIR COND TEMP CONTROL G SETPOINT A B C COMPRESSOR Remote Temp RMT A B C Cond Temp Sensor LIGHT RECPT 2 PWR (+) PWR (-) SPEED CONTROL BOARD G LOCAL J11 (+) MML (-) 1 J10 MINOR 2 MINOR 3 MAJOR 4 MAJOR HOT SETPOINT N 18C 23C SHDOWN ALARM 28C 33C 38C NC NC MINOR N0 MAJOR N0 1 J12 PWR (+) 2 PWR (-) LIGHT RECPT 2 J1 875-089-20 AIR COND TEMP CONTROL Evap temp SPEED CONTROL BOARD EVAP FANS Evap Temp Sensor RMT 1 J12 PWR (+) 2 PWR (-) 20A HOT LOAD N LOCAL Remote Temp AIR CONDITIONER - DC 18C 23C SHDOWN ALARM 28C 33C 38C NC NC MINOR N0 MAJOR N0 J1 HOT (+) MML (-) N AIR COND TEMP CONTROL Evap temp N J11 Cond Temp Sensor TAMPER EVAP FANS Evap Temp Sensor GFCI OUTLET LINE G SETPOINT COND FANS DOOR SW DOOR SW TAMPER COMPRESSOR J1 PWR (+) PWR (-) Remote Temp (+) MML (-) J11 A B C FLORESCENT LAMP 1 J12 PWR (+) 2 PWR (-) HOT LOAD RMT TAMPER 1 J10 MINOR 2 MINOR 3 MAJOR 4 MAJOR HOT SETPOINT 1 J10 MINOR 2 MINOR 3 MAJOR 4 MAJOR N LOCAL 875-055-21 875-055-20 GFCI OUTLET LINE G SPEED CONTROL BOARD 18C 23C SHDOWN ALARM 28C 33C 38C NC NC MINOR N0 MAJOR N0 FLORESCENT LAMP 1 J12 PWR (+) 2 PWR (-) DOOR SW DOOR SW AIR COND TEMP CONTROL Evap temp COND FANS Cond Temp Sensor ML3 20A GMT FUSE -48VDC A/B 10/10 (-) A L1 L2 (+) B Fuse Fail B COM NC 875-587-20 30A (Optional) AC Gen Inlet 5 6 7 8 9 10 240V M3&M4 25A 15A 15A 2 1 8 7 6 5 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 240V M1&M2 25A DIGITAL INPUTS NET CAN 1 Input (-) Input (+) 4 TEMP 2 (-) TEMP 2 (+) TEMP 1 (-) TEMP 1 (+) 3 D8 D8 D7 D7 D6 D6 D5 D5 D4 D4 D3 D3 D2 D2 D1 D1 60A RS485 RS232 11 12 16 Encl TAMPER 17 ALM OUTPUT 1 ALM OUTPUT 2 ALM OUTPUT 3 ALM OUTPUT 4 ALM OUTPUT 5 ALM OUTPUT 6 ALM OUTPUT 7 ALM OUTPUT 8 ALM OUTPUT 0 (+) GND RETURN (-) CHARGE 2 -48V BATTERY L2 50A 50A 1 584 PANEL 48V CXC LLVD 8CB L1 1st Encl GFCI BBX 12CKT LOAD CENTER 18 19 20 21 NEUT 22 GND 875-594-20 COOLING SYS 1 MAJOR 24 COOLING SYS 1 MINOR 25 1 2 OUTPUT (+) M2 Module 3 M4 L1 L2 175 A COOLING SYS 2 MIN 14 GRN 15 16 Encl TAMPER 17 18 19 20 21 YEL 22 RED YEL GRN RED YEL ORG BLU BRN 5 RED Module 4 CORDEX 48 1800W 4 MOD BULK SHELF BAT COMP FAN 23 COOLING SYS 1 MAJOR 24 COOLING SYS 1 MINOR 25 2 Battery Storage Unit 12-Space AC Load Center Surge Protector 3W+G 4 Module 1.8KW Cordex Shelf with Controller 584 DIST Pandel with Load LVD, 8 BKR POS 120VAC 60Hz GFCI outlets 120VAC 60Hz Lights Enclosure Intrusion Sensors 2 Enclosure Alarm Terminal Boards RED 3. SYSTEMS WITH 1KW OR 1.8KW CORDEX RECTIFIER OPTIONS MAY REQUIRE AC GENERATOR INLET, TYPE IEC 309-2 WITH 60AMP MINIMUM BREAKER SIZE IF SYSTEM LOAD IS GREATER THEN 5KW. 875-110-21 875-125-22 875-071-20 1 2 PWR (+) PWR (-) PWR (+) PWR (-) Fan1 (+) Fan1 (-) J2 J1 CL = ALM C J3OP = ALM J4 1 2 3 4 1 2 3 (+) (-) DC FAN TAMPER 125A 12V BATTERY Battery Compartment Fan ML2 TRAY GROUND 12V BATTERY ML2 TAMPER 12V BATTERY 12V BATTERY 875-110-21 12V BATTERY 1 2 875-059-20 12V BATTERY 875-110-21 12V BATTERY 120A 875-068-20 125A 875-068-20 120A 12V BATTERY Single Side Chamber 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 120A 875-059-20 ENCL GROUNDBAR 1 COOLING SYS 2 MAJ 13 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 4 -48VDC POSITIVE GND SYSTEM BLACK (-) HOT RED (+) COMMON M3 L1 L2 3 DC GEN INLET Module 2 GND GND 875-125-21 E2 2 HOT L1 L2 E1 12 120A 1 2 OUTPUT (-) Module 1 CAN OUT 875-125-20 Neutral ENCL GROUNDBAR 1 Line 1 Line 2 875-593-20 M1 L1 L2 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 1 120A 1 2 SURGE PROTECTOR 3W+G 23 Cordex 48VCD 1.8kw Module Bulk Shelf 1 2 GND BAT COMP FAN 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Double Wide Enclosure with (4) 48VDC Air Cond Doors PCBA - ALARM CROSS CONNECT 875-071-20 N TB4 COMMON - B 875-589-21 GND TB3 HOT - B TB2 COMMON - A Model: RMB-48 1.8K CORDEX with options: 875-529-20 PCBA - ALARM CROSS CONNECT GRN (Intrusion) GRN 1 1 1 RED RED(Cool MAJ 2 2 YEL (Cool Min) YEL 3 3 2 ORG (Cust MAJ) ORG 4 4 BLU (Cust Min) BLU 5 5 3 6 6 7 7 GRN (Jumper) 4 GRN 8 8 9 9 5 BRN (GMT Fuse Optional) ORG 10 10 11 11 BLU (Jumper) 6 BLU 12 12 13 13 7 14 14 15 15 8 16 16 17 17 2E BAT COMP FAN 9 YEL 18 18 19 19 2E COOLING MAJOR 10 20 20 21 21 2E COOLING MINOR 11 22 22 23 23 2Encl TAMPER 12 GRN 24 24 25 25 COOLING SYS 2 MAJ 13 RED 26 26 27 27 YEL COOLING SYS 2 MIN 14 28 28 29 29 GRN WATER INTR (option) 15 30 30 COM (-) B Fuse Fail A COM NC HOT 240VAC 60Hz Input Power TB1 HOT - A ENCL GROUNDBAR 1 (+) A COM Customer Provided 1 2 1 2 PWR (+) PWR (-) PWR (+) PWR (-) Fan1 (+) Fan1 (-) J2 J1 CL = ALM C J3OP = ALM J4 1 2 3 4 1 2 3 (+) (-) DC FAN 2. WHEN A SEALED MINIBAY EQUIPMENT ENCLOSURE IS USED TO HOUSE BATTERY PACKS, BATTERIES MUST BE VALVE REGULATED AND PROVITIONS SHOULD BE MADE FOR ADIQUIT HYDROGEN VENTING. 1. Battery Compartment Fan TRAY GROUND TAMPER NOTE: UNLESS SPECIFIED OTHERWISE DRAWN TAMPER 2ND BATTERY STORAGE UNIT D. JOHNSTON 5-15-06 D. JOHNSTON 5-15-06 CHK ENGR 1ST BATTERY STORAGE UNIT LENGTH OF WIRES CAN BE CUT TO FIT IF REQUIRED. REMAKE TERMINATE USING THE SAME ALPHA WORKMANSHIP & PARTS. ALPHA TECHNOLOGIES MANUF Q.A. PLOTTED ON: TITLE: 25-May-2007 14:36:47 SCHEMATIC RADIUM MINIBAY SYSTEM ISSUED DATE: REV: 044-001-05 EARTH GROUND TO CUSTOMER INSTALLED GROUND RING DRAWING NO: FILE REF: 04400105___C__W09.SCH SIZE: D SHEET C 9 OF 12 PRIMARY ENCLOSURE Factroy set to 40C open on rise 875-126-20 FLORESCENT LAMP ADJ. TSTAT GND N L1 DOOR SW L2 2 3 4 5 6 7 8 BBX 8 CKT LOAD CENTER L1 9 1 L2 2 60A 10 11 3 4 15A TAMPER 12 TAMPER 13 5 14 6 15 7 16 8 NEUT 17 18 GND 19 LINE G 20 N 21 HOT HOT LOAD GFCI2 22 N 23 24 GROUNDBAR - ENCL 875-075-20 25 5A INLINE FUSE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 COM 1 Customer Provided Input HOT PCBA - ALARM CROSS CONNECT RMB with 115VAC Heat Exchanger (OR 115VAC Fan Filter) Door 1 2 3 4 Model RMB with options: 5 6 1 Enclosures with 115VAC Heat Exchanger (or Fan Filter) Doo) 7 Battery Riser 8 9 60A FBX 8-position Distribution 10 Alarm Terminal Boards 11 12 Enclosure Intrusion Sensors 13 14 ENCLOSURE OVERTEMP (ADJ) - open on alarm 15 WATER INTRUSION - open on alarm (optional) 16 TAMPER - open on alarm GFCI outlet & Enclosure Light Enclosure Roof Vent Kit 17 18 19 20 21 22 23 24 25 Heat Exchanger (or Fan Filter Door) Option CLOSE AT 30C / 85F TSTAT 875-128-20 1 2 3 FAN - AC L N GND ML3 875-076-21 CUSTOMER INSTALLED GROUND RING 1 2 3 EARTH GROUND Battery Compartment Fan COOLING FAN 875-076-20 1 L 2 N 3 GND FAN - AC MML3 CLOSE AT 30C / 85F FAN - AC L N GND 5A INLINE FUSE FLOAT SW TSTAT BATTERY TRAY GND TAMPER BATTERY STORAGE UNIT TAMPER 3. SYSTEMS WITH 1KW OR 1.8KW CORDEX RECTIFIER OPTIONS MAY REQUIRE AC GENERATOR INLET, TYPE IEC 309-2 WITH 60AMP MINIMUM BREAKER SIZE IF SYSTEM LOAD IS GREATER THEN 5KW. 2. WHEN A SEALED MINIBAY EQUIPMENT ENCLOSURE IS USED TO HOUSE BATTERY PACKS, BATTERIES MUST BE VALVE REGULATED AND PROVITIONS SHOULD BE MADE FOR ADIQUIT HYDROGEN VENTING. 1. LENGTH OF WIRES CAN BE CUT TO FIT IF REQUIRED. REMAKE TERMINATE USING THE SAME ALPHA WORKMANSHIP & PARTS. NOTE: UNLESS SPECIFIED OTHERWISE DRAWN D. Johnston 5-15-06 D. Johnston 5-15-06 CHK ENGR ALPHA TECHNOLOGIES MANUF Q.A. PLOTTED ON: TITLE: 25-May-2007 14:37:19 SCHEMATIC RADIUM MINIBAY SYSTEM ISSUED DATE: DRAWING NO: REV: 044-001-05 FILE REF: 04400105___C__W10.Sch SIZE: D SHEET C 10 OF 12 PRIMARY SIDE CHAMBER PRIMARY ENCLOSURE SECONDARY SIDE CHAMBER SECONDARY ENCLOSURE NOTE: OVER TEMP ALARM IS FACTORY SET TO 40C NOTE: OVER TEMP ALARM IS FACTORY SET TO 40C 875-126-20 TAMPER 875-126-20 ADJ. TSTAT ADJ. TSTAT TAMPER TAMPER COND FANS 4 5 6 AC AIR COND 7 8 9 60A 10 N Gnd Bshg 11 12 875-259-20 13 L1 14 15 16 1 L2 17 60A 2 18 3 19 4 20 #1 240V AC Air Cond 5 21 15A 6 22 #2 240V AC Air Cond 7 23 15A 8 Dual Enclosures with two 240VAC Air Cond Door 24 L2 L1 1 2 G 3 4 5 OUTLET 1X240V 6 1 2 COND FANS 3 4 AC AIR COND 5 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 ENCL OVERTEMP (ADJ) - open on alarm 14 15 15 16 TAMPER - open on alarm 16 17 17 18 18 19 19 20 20 21 21 22 22 23 23 24 Cooling system Major - open on alarm 24 25 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Dual Battery Riser 1 2 EUSERC Meter w/60A FBX 8-position Distribution 3 Surge Protector 3W+G 4 5 2 Alarm Terminal Boards 6 Enclosure Intrusion Sensors 7 8 Fiber Managment Panel 9 Enclosure Roof Vent Kit 10 11 12 13 14 ENCL OVERTEMP (ADJ) - open on alarm 15 16 TAMPER - open on alarm 17 18 19 20 21 22 23 24 Cooling system Major - open on alarm 25 SURGE PROTECTOR 3W+G GROUNDBAR - ENCL GROUNDBAR - ENCL Line 1 Line 2 GND Neutral GROUNDBAR - ENCL GND NEUT 25 Dual Side Chambers PCBA - ALARM CROSS CONNECT COMPRESSOR 3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 COM COMPRESSOR L2 L1 875-258-20 G 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 HOT 1 L2 L1 ALARM EVAP FANS PCBA - ALARM CROSS CONNECT OUTLET 1X240V BBX 8 CKT LOAD CENTER Model RMB with options: MML2 EVAP FANS COM ALARM Gnd Bshg 60A FUSE DISCONNECT 875-315-22 MML2 METER G 875-377-20 HOT L2 L1 N USERC METER BASE 875-377-20 875-315-22 N TAMPER RMB with 240VAC Air Cond TAMPER TAMPER 875-125-23 875-125-22 MAIN GROUNDBAR - SIDE CHAMBER 875-125-20 875-125-21 3. SYSTEMS WITH 1KW OR 1.8KW CORDEX RECTIFIER OPTIONS MAY REQUIRE AC GENERATOR INLET, TYPE IEC 309-2 WITH 60AMP MINIMUM BREAKER SIZE IF SYSTEM LOAD IS GREATER THEN 5KW. 1ST BATTERY RISER 2ND BATTERY RISER 2. WHEN A SEALED MINIBAY EQUIPMENT ENCLOSURE IS USED TO HOUSE BATTERY PACKS, BATTERIES MUST BE VALVE REGULATED AND PROVITIONS SHOULD BE MADE FOR ADIQUIT HYDROGEN VENTING. EARTH GROUND TO CUSTOMER INSTALLED GROUND RING 1. LENGTH OF WIRES CAN BE CUT TO FIT IF REQUIRED. REMAKE TERMINATE USING THE SAME ALPHA WORKMANSHIP & PARTS. NOTE: UNLESS SPECIFIED OTHERWISE DRAWN D. JOHNSTON 5-15-06 D. JOHNSTON 5-15-06 CHK ENGR ALPHA TECHNOLOGIES MANUF Q.A. PLOTTED ON: TITLE: 25-May-2007 14:38:06 SCHEMATIC RADIUM MINI BAY SYSTEM ISSUED DATE: DRAWING NO: REV: 044-001-05 FILE REF: 04400105___C__W11.Sch SIZE: D SHEET C 11 OF 12 FLORESCENT LAMP PRIMARY SIDE CHAMBER PRIMARY ENCLOSURE AIR CONDITIONER - DC EVAP FANS Evap Temp Sensor N HOT HOT LOAD J1 TAMPER A B C COMPRESSOR Remote Temp (+) MML (-) TAMPER PWR (+) PWR (-) SETPOINT RMT J11 1 J10 MINOR 2 MINOR 3 MAJOR 4 MAJOR 875-055-20 GFCI OUTLET LINE G LOCAL SPEED CONTROL BOARD 18C 23C SHDOWN ALARM 28C 33C 38C NC NC MINOR N0 MAJOR N0 FLORESCENT LAMP 1 J12 PWR (+) 2 PWR (-) DOOR SW DOOR SW AIR COND TEMP CONTROL Evap temp COND FANS Cond Temp Sensor N AIR CONDITIONER - DC 20A EVAP FANS Evap Temp Sensor A B C COMPRESSOR RMT PWR (+) PWR (-) Remote Temp LOCAL J1 G J11 (+) MML (-) 875-089-20 1 J10 MINOR 2 MINOR 3 MAJOR 4 MAJOR HOT 1 J12 PWR (+) 2 PWR (-) N SETPOINT 18C 23C SHDOWN ALARM 28C 33C 38C NC NC MINOR N0 MAJOR N0 LIGHT RECPT 2 SPEED CONTROL BOARD AIR COND TEMP CONTROL Evap temp COND FANS Cond Temp Sensor 20A 875-089-20 GMT FUSE -48VDC A/B 10/10 N L1 (+) A L2 TB1 HOT - A (-) B TB3 HOT - B TB2 COMMON - A Fuse Fail B COM NC TB4 COMMON - B 875-589-21 (+) B PCBA - ALARM CROSS CONNECT GRN (Intrusion) GRN 1 1 1 RED RED(Cool MAJ 2 2 YEL (Cool Min) YEL 3 3 2 ORG (Cust MAJ) ORG 4 4 BLU (Cust Min) BLU 5 5 3 6 6 7 7 GRN (Jumper) 4 GRN 8 8 9 9 GMT FUSE MAJ 5 ORG 10 10 11 11 Cust Min (Option) 6 BLU 12 12 13 13 7 14 14 15 15 8 16 16 17 17 YEL BAT COMP FAN 2 (Jumper) 9 18 18 19 19 10 20 20 21 21 11 22 22 23 23 2Encl TAMPER (Jumper 12 GRN 24 24 25 25 COOLING SYS 2 MAJ 13 RED 26 26 27 27 YEL COOLING SYS 2 MIN 14 28 28 29 29 GRN WATER INTR (option) 15 30 30 Fuse Fail A COM NC 875-587-20 6 25A 7 8 9 10 240V M3&M4 25A 15A 15A 11 12 2 1 8 7 6 5 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 240V M1&M2 NET CAN 1 Input (-) Input (+) 5 DIGITAL INPUTS (BREAKERS OPTIONAL) TEMP 2 (-) TEMP 2 (+) TEMP 1 (-) TEMP 1 (+) 30A D8 D8 D7 D7 D6 D6 D5 D5 D4 D4 D3 D3 D2 D2 D1 D1 4 (Optional) AC Gen Inlet RS485 RS232 30A 16 Encl TAMPER 17 ALM OUTPUT 1 ALM OUTPUT 2 ALM OUTPUT 3 ALM OUTPUT 4 ALM OUTPUT 5 ALM OUTPUT 6 ALM OUTPUT 7 ALM OUTPUT 8 ALM OUTPUT 0 (+) GND RETURN (-) CHARGE 3 -48V BATTERY 2 60A 50A 50A 1 L2 584 PANEL 48V CXC LLVD 16CB L1 1st Encl GFCI BBX 12CKT LOAD CENTER 18 19 20 21 NEUT 22 GND 875-528-23 BAT COMP FAN 23 COOLING SYS 1 MAJOR 24 COOLING SYS 1 MINOR 25 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Cordex 48VCD 1.8kw Module Bulk Shelf Alarm (Optional) M3 -48VDC POSITIVE GND SYSTEM BLACK (-) HOT RED (+) COMMON 5 Module 3 M4 L1 L2 HOT 4 Module 2 L1 L2 3 GEN INLET Side chamber riser 2 Battery Storage Unit 12-Space AC Load Center Surge Protector 3W+G 30A Max CB Limited (Alarm Contact Option) 4 Module 1.8KW Cordex Shelf with Controller 584 CB DIST Panel with Load LVD, 16 BKR POS 120VAC 60Hz GFCI outlets 120VAC 60Hz Lights Enclosure Intrusion Sensors GRN Enclosure Alarm Terminal Board GMT Fuse Panel A/B (Optional) AC Generator inlet (Optional) YEL RED YEL GRN RED YEL ORG BLU RED 3. Module 4 GND GND 875-068-20 120A 125A 12V BATTERY 12V BATTERY 12V BATTERY 875-110-21 875-059-20 ENCL GROUNDBAR 1 SURGE PROTECTOR 30A MAX CB LIMITED 3W+G 1 2 E2 2 CAN OUT Neutral GND 1 2 OUTPUT (+) M2 L1 L2 E1 875-071-20 Line 1 Line 2 OUTPUT (-) Module 1 Single Side Chamber 120A ENCL GROUNDBAR 1 875-593-20 M1 120A 1 2 L1 L2 1 175 A 1 2 A? 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Enclosure with two 48VDC air cond doors COM 240VAC 60Hz Input Power GND CSB: RMB-48, 1.8K CORDEX with options: (-) A Customer Provided 12V BATTERY 1 2 1 2 PWR (+) PWR (-) PWR (+) PWR (-) Fan1 (+) Fan1 (-) J2 J1 CL = ALM C J3OP = ALM J4 Battery Compartment Fan ML2 1 2 3 4 1 2 3 (+) (-) TAMPER DC FAN TAMPER 2. WHEN A SEALED MINIBAY EQUIPMENT ENCLOSURE IS USED TO HOUSE BATTERY PACKS, BATTERIES MUST BE VALVE REGULATED AND PROVITIONS SHOULD BE MADE FOR ADIQUIT HYDROGEN VENTING. 1. BATT HEATER TRAY GROUND SYSTEMS WITH 1KW OR 1.8KW CORDEX RECTIFIER OPTIONS MAY REQUIRE AC GENERATOR INLET, TYPE IEC 309-2 WITH 60AMP MINIMUM BREAKER SIZE IF SYSTEM LOAD IS GREATER THEN 5KW. BATTERY STORAGE UNIT 1 LENGTH OF WIRES CAN BE CUT TO FIT IF REQUIRED. REMAKE TERMINATE USING THE SAME ALPHA WORKMANSHIP & PARTS. NOTE: UNLESS SPECIFIED OTHERWISE 120A 125A 12V BATTERY 12V BATTERY 12V BATTERY ML2 DRAWN D. JOHNSTON 9-14-06 D. JOHNSTON 9-14-06 CHK 875-110-21 12V BATTERY TAMPER ENGR MANUF TAMPER Q.A. PLOTTED ON: TRAY GROUND BATT HEATER BATTERY STORAGE UNIT 2 ALPHA TECHNOLOGIES TITLE: 25-May-2007 14:38:55 SCHEMATIC RADIUM MINIBAY SYSTEM ISSUED DATE: REV: 044-001-05 EARTH GROUND TO CUSTOMER INSTALLED GROUND RING DRAWING NO: FILE REF: 04400105___C__W12.SCH SIZE: D SHEET C 12 OF 12