Transcript
OPERATING AND FITTING INSTRUCTIONS
PROGRAMMABLE TIMER MODULE
RANGER The ELECTRICAL
select
GUARANTEE The Select Ranger is guaranteed for five years from date of purchase to be free from defects in materials and workmanship. This only applies if the Select Ranger is used in the correct way. The guarantee is also conditional on the product not having been tampered with, modified or subject to attempted repairs. Your statutory rights as a customer are not affected. If the Select Ranger is faulty please return to place of purchase.
UK PATENT No. 2 290 418
HK PATENT No. 10044303A
Philex Electronic Ltd, Philex House, 110 The Broadway, West Hendon, London NW9 7PP
THE SELECT RANGER PROGRAMMABLE TIMER Thank you for purchasing the Select Ranger. A high quality timing system that will allow you a facility that has never previously been available. Ingenious design and foresight has enabled us to produce an innovative product which will allow you to set switches and sockets to a timing device. Please read the following instructions carefully and heed all warnings, especially about electricity. 1. General Features • 7 ON and OFF programs per day with 1 minute step • 24 hour display mode • 7 days/Mon-Fri/Sat-Sun/or each day settings pair (ON & OFF) selection 1. 7 days all the same 2. a) Mon-Fri the same b) Sat-Sun the same 3. Individual settings for each day • Override programmable countdown timer by a separate key activation (Ranger 2 & 3) • ON/OFF/AUTO/ RANDOM/ COUNTDOWN MODE/ SELECTION All separate for each model • Summer time setting • Manual ON/OFF. For continuous operation • Reset Button (resets to zero) • 6 keys: DAY, HOUR, MIN, TIME SET, PROG and MODE (Ranger 1) • 7 keys: DAY, HOUR, MIN, TIME SET, PROG, MODE and COUNTDOWN (Ranger 2 & 3) 2. Electrical Specifications • Rated voltage 250V~/ current 6A (EN60669)m current 13A (EN60730) • Timer accuracy to +/-2 sec per day at 25C • Operating temp: 0 to 50 degrees C • Uses 1 x AAA alkaline non-rechargeable battery (not included). Not suitable for use with rechargeable batteries • For continuous operation • • • • • • • • •
3. Contents: Timer Module 2x Main Bracket 2x Bracket extension piece 1x Angle Bracket (can be easily removed for your convenience) Retaining screws (already fitted) + 2 extra short screws 2x extended switch/socket screws 1x one-way connector terminal block 1x adhesive pad Instructions
4. Battery Connection • Remove battery cover on front of appliance • Place 1 x AAA into compartment ensuring + to right / - to left • Replace cover • NB: If battery is inserted incorrectly, wait 30 seconds before replacing correctly. • By utilising a battery circuit your Select Ranger timer programme is not affected by a power failure.
S
MO TU WE TH FR SA SU
PGM
OFF AUTO ON RAND
a d e
DAY
HOUR
MIN
TIME SET
PROG
MODE
b c f g
COUNTDOWN
h
5. Keyboard definition • a. Day. • set day of week • toggle output in AUTO/RANDOM/COUNTDOWN MODE • b. Hour. Set current time and program time • c. Min. Set current time and program time, changes minutes in countdown mode • d. Time Set. Set the current time • e. Prog. Select and set program • f. Mode. Select the operation mode • g. Countdown. Activate the countdown timer mode On immersion and professional models only • h. Reset
1
6. Power Up • All segments will be ON for 2 secs after battery insertion • Default time: 00:00 Monday • All program timers are un-set i.e. —:— • Default operation mode : manual OFF • If battery is removed for any reason, wait 30 seconds before re-insertion
S
MO TU WE TH FR SA SU
00 : 00
PGM
OFF AUTO ON RAND
7. Display Mode • Normal time display • Timer • Clock displays in day, hour and minute • Colon flashes at a rate of 1Hz • Clock updates every minute • Other •
Indicator represents output is ON
•
Indicator represents output is OFF MO
00 : 00 OFF • Countdown timer display On immersion heater and professional models only (Ranger 2 & 3)
• Timer displays in MINUTE only • Other • Indicator shows when the timer is setting and flashes when the timer is counting
8. Setting Mode • Clock Setting Mode • Available in Manual ON, Manual Off and AUTO mode only • If setting in Summer Time, read section below • Press and continually hold key TIME SET to enter in clock setting mode • Colon will become solid • Press either HOUR MIN or DAY to set the clock time and day • Hold key HOUR MIN or DAY for 2 sec to enter fast advance (continuous turnover will commence) • Release key TIME SET will set the clock and exit the clock setting mode • Clock second will be set to ZERO once HOUR, MIN or DAY is pressed • NB: Don’t forget the special Summer Time setting - see section below
PGM
• Summer Time Setting Mode • Available in Manual ON, Manual OFF and AUTO modes only • Press TIME SET and PROG simultaneously for 3 seconds to set • ‘S’ indicator ON when activated • Clock advances one hour • If setting clock during Summer Time, set for one hour early, then advance time using the procedure above • Winter Time, follow procedure above to return clock to winter setting
S
75 2
-- : --
WE
0 : 45 AUTO
• Program Setting Mode 1. Available in Manual ON, Manual OFF and AUTO modes only 2. Press PROG to enter setting mode 3. Prg1 will be shown
PGM
• • • • • • •
Manual Off Mode Press MODE to select MANUAL OFF mode OFF indicator displayed Normal clock display All programs are ignored Output is permanently OFF Allows both Clock setting and Program setting
• • • • • • • •
Auto Mode Press MODE to select AUTO indicator ON Normal display clock Press DAY to toggle output Allows both Clock setting and Program setting Program output control is activated NB If there are program time overlapping, the higher program number has the highest priority. PROG OFF always has priority over PROG ON
• • • • • • •
Manual ON Mode Press MODE to select ON indicator displayed Normal clock display All programs are ignored Output is permanently ON Allows both Clock setting and Program setting
MO TU WE TH FR SA SU PGM 1
06 : 30 MO TU WE TH FR SA SU
Example 2: To set OFF
75
-- : --
4. There are up to 7 program modes 5. ON and OFF are designated by the relevant symbols 6. —:— indicates there are no presets in place 7. Press DAY to all days MON-SUN, MON-FRI, SAT-SUN, individual days, program clear and then repeat 8. Press HOUR, MIN to set the program time (fast advance as previous) 9. Press PROG to Prg1 OFF’s program (or next in sequence) 10. To set remaining programs repeat from step 7 11. Press PROG again to advance the program number 12. Press TIME SET to exit setting mode 13. Auto return to clock if idle for 3 mins Example 1: To set ON
• Press TIME SET to toggle between countdown timer and normal clock display • Press COUNTDOWN to exit countdown timer and change to return to auto mode
PGM 1
09 : 45
• Countdown Timer Setting Mode
• Random Mode
On immersion heater and professional models only (Ranger 2 & 3)
On security lighting and professional models only
• Press COUNTDOWN to enter mode • Press key MIN within 5 secs to set the countdown timer • Clock shows 75 and cycles down in 15 minute segments (75, 60, 45, 30, 15, 1, then back to 75) • Countdown timer will activate if no other key is pressed within 5 seconds indicator will flash during countdown
• • • • • • • • •
Press MODE to select RAND indicator ON Normal clock display All programs are ignored Clock setting and Program setting is not possible Random output control is activated Frequency: 4-12 times per day ON period: 5-60 minutes Output is ON when activated
3
WARNING: DISCONNECT MAINS POWER PRIOR TO INSTALLATION
IMPORTANT - It is recommended that you program the timer before attaching the module to the switch/socket. See programming instructions.
FITTING INSTRUCTIONS
A
The Select Ranger comes complete with a universal bracket which will allow you to fit it to single or twin switches, also single or twin socket outlets (switched/unswitched). N.B. The Select Ranger should only be fitted to flat surfaces. The Select Ranger can be fitted to the left or right of the switch or socket outlet. The Select Ranger is for FLUSH mounting only. Most domestic sockets and switches are flush mounted. Supplied already assembled for attachment to the right hand side of the switch/socket, it is easily converted for left hand use. 1 To convert the module: 1. Remove the two screws in the back of the bracket. 2. Remove the module 2 from the bracket housing. 3. Turn bracket through 180 degrees so that the legs are pointing in the opposite direction. 4. Replace the module 3 into the bracket housing, inserting the two wires from the module through the hole in the bracket housing. 4 5. Replace the two retaining screws through the back of the bracket housing into the screw holes in the module and tighten.
LIGHT SWITCH Not Suitable for 2 Way Switches * When connecting to a two gang switch (2 switches on one plate) attach your Select Ranger to one switch only. 1. After switching off the mains, remove the two screws that hold the switch to the wall. 2. Pull the switch gently away from the wall. DO NOT REMOVE ANY WIRES. 3. Place the module and bracket housing over the open switch box. 4. Loosen screw to mains input (in the back of the switch) without removing any wires. 5. Insert the chosen module live wire into the input and tighten screw to secure. 6. Put the other module wire into the switch output. Follow steps 4 and 5 to complete the procedure. 7. Ensure all wires are secure in relevant ports. 8. Assemble the rest of the bracket (see below) and align with screw holes in the switch box. 9. A double-sided sticky pad is provided to secure the bracket to the wall. 10. Position the switch plate over the bracket aligning the screw holes. Using the extended screws provided, secure the whole assembly to the wall. 11. When the assembly is fully secure you can switch on the mains. 12. The Select Ranger is now ready for use.
*A 2 Way switch is defined as being one of two light switches which operate the same light from different locations.
LIGHT SWITCH ASSEMBLY
IMPORTANT When fitting the Select Ranger to a light switch it should be protected by an in-line fuse. However, as long as your premises are fitted with a fuse box or consumer unit, no additional fuse is required.
5
4
WARNING: DISCONNECT MAINS POWER PRIOR TO INSTALLATION B
IMMERSION HEATER SWITCH (Ranger 2) For immersion heater follow instructions for 13 amp sockets.
C
13 AMP SOCKETS Single/Twin/Switched/Unswitched NB. For the timer module to operate effectively on your 13 amp socket, it needs to be fitted differently to the module being attached to a light switch. 1. After switching off the mains, remove the two screws holding the socket front plate to the wall. 2. Pull the front plate gently away from the wall. DO NOT REMOVE ANY WIRES YET. 3. Place the module and bracket over the open socket. Identify the LIVE WIRE on the back of the socket and undo the screw holding it in place. 4. Using the connector provided join the LIVE WIRE to the chosen module live wire (see diagram below). Undo screws, place live wire in one end and module wire in the other and tighten screws. LIVE WIRE to socket
LIVE WIRE to Timer Module
5. Insert the other module wire into the LIVE terminal on the back of the socket and tighten the screw. 6. Ensure that all wires are secure. 7. Assemble the rest of the bracket and align with the screw holes in the socket box. 8. Use the double-sided sticky pad provided to secure the bracket to the wall. 9. Position the socket front plate over the bracket aligning the screw holes. Using the extended screws provided secure the whole assembly to the wall. 10. Switch on the mains. 11. The Select Ranger is now ready for use. 12. For the socket to operate normally ensure that the timer module is in DOUBLE SOCKET ASSEMBLY the ON mode. 5
SINGLE SOCKET ASSEMBLY
13. When wishing to put the timer programme into OPERATION mode and ensure that the timer module is in AUTO mode and leave the socket switch(es) in the ON position.
D ANGLE BRACKET This bracket has been provided to give an improved viewing angle (particularly useful when attaching the module to low mounted sockets). To fit the angle bracket, remove the module from the main bracket (see page 4). Place the angle bracket over the main bracket, ensuring that the lips are fitted over the main bracket. Replace module as before (see page 4). E DIMMER SWITCH One Way only OPTION 1 - Fit as if to a normal light switch. When operating the light through your Select Ranger the light will come on at full intensity. The dimmer switch will operate normally. OPTION 2 - Fit as if to a socket. This will allow you to adjust the setting on the dimmer. NOTE: (Option 2 only) For the dimmer switch to operate normally the Select Ranger must be in the ‘ON’ mode. To operate the lights with the timed programmes, the Select Ranger must be in the ‘AUTO’ mode with the dimmer switch on and adjusted to the correct setting NB: NOT SUITABLE FOR FITTING TO SURFACE MOUNTED SWITCHES OR SOCKETS. Surface mounted refers to switches or sockets which are mounted on a pattress (base box) affixed to a wall. As with most industrial/commercial sockets. See diagram. FAULT FINDING 1. If the LCD fails to come on, check that the battery is fitted correctly. 2. If the module fails to operate the timer programme, check for low battery and replace if necessary. 3. If the LCD locks in one position, press the RESET button then follow the setting/programming instructions.
IF YOU ARE IN DOUBT ABOUT ANY OF THESE FITTING INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICIAN.