Rapid Fiber Collector Box Installation And Cable

   EMBED


Share

Transcript

2 Rapid Fiber Collector Box Install Mounting Bracket on Wall Position mounting bracket on wall as shown and secure with four wood screws (provided). Installation and Cable Routing Instructions 3/4” PLYWOOD PANEL FASTENED TO WALL ADCP-90-375 · Issue 3 · 09/2009 NOTE: 1 INSTALL WOOD SCREWS (PROVIDED) Installation and assembly can be completed by one person. Refer to Figure 7 for additional information. Dimensions MOUNTING BRACKET 2.8 IN. 7.0 IN. 3 10.0 IN. ! Align Panel with Mounting Bracket 1. Remove three nuts from panel, as shown. 2. Align screw in bottom of panel (not shown) with hole in bracket. 3. Position panel on bracket. 4 Secure Panel to Mounting Bracket Secure panel to mounting bracket using nuts removed in previous step. Warning: Wet conditions increase the potential for receiving an electrical shock when installing or using electrically-powered equipment. To prevent electrical shock, never install or use electrical equipment in a wet location or during a lightning storm. SCREW (NOT SHOWN) Danger: ! Infrared radiation is invisible and can seriously damage the retina of the eye. Do not look into the ends of any optical fiber. Do not look directly into the optical adapters of the adapter packs. Exposure to invisible laser radiation may result. A protective cap or hood MUST be immediately placed over any radiating adapter or optical fiber connector to avoid the potential of dangerous amounts of radiation exposure. This practice also prevents dirt particles from entering the connector and adapter. 22609-B 1455255 Rev B ADC and ADC Telecommunications are registered trademarks of ADC Telecommunications, Inc. 2008©, ADC Telecommunications, Inc. 5 Collector Panel Description and (F1) Feeder Cable Routing The figure to the right shows the Collector Panel as shipped. LABEL CIRCUITS ACCORDING TO LOCAL PRACTICE MPO CONNECTOR MPO DUST CAP (REMOVE BEFORE CONNECTING FDT CABLES) GROUND LOCATION. GROUND PANEL PER LOCAL PRACTICE. DOOR LOCK en. when op diation SURE TO laser ra Invisible OR SKIN EXPODIATION. E RA AVOID EY SCATTERED OR DIRECT 7 USE 216 TOOL TO OPEN Additional Information SHIP ALONG ITEMS: CABLE CLAMP ITEM STRAIN RELIEF COLLAR QTY SEE STEP: Wood screw 4 2 Cable Ties 6 6 FEEDER CABLES TO iFDH (Indoor Fiber Distribution Hub) TOOLS REQUIRED: 6 Customer Cable Routing Slide fibers between entrance foam. Remove dust caps and terminate cables from RDT equipment as shown. Use label on door to record terminations. ITEM SEE STEP: Screw driver (Phillips) 2 216 tool 5 MAINTENANCE: ADC recommends cleaning fiber connectors per ADCP-96-150 The MT Collector can support up to six 12-fiber RDT’s or three 24-fiber RDT’s. REPRINTS: PDF copies of manuals are available for downloading at the following link: www.adc.com/manuals CABLE STRAIN RELIEF SHOULD BE PROVIDED BY STANDARD CABLE RUN INSTALLATION PRACTICES 90-375 SLIDE FIBERS BETWEEN ENTRANCE FOAM WRAP FIBERS TWICE AROUND RADIUS LIMITERS. USE CABLE TIES (PROVIDED) TO SECURE FIBERS. ! ADCP Number: CABLES FROM RDT EQUIPMENT ADC TELECOMMUNICATIONS, INC PO BOX 1101, MINNEAPOLIS, MN 55440-1101, USA ATTN: TECHNICAL ASSISTANCE CENTER: 1-800-366-3891, EXT: 73475 www.adc.com 22610-B 1455255 Rev B · ADCP-90-375 · Issue 3 · 09/2009 2008©, ADC Telecommunications, Inc.