Preview only show first 10 pages with watermark. For full document please download

Rapport3 Manual(e)_110207(no Logo).ai

   EMBED


Share

Transcript

Multi Functional CCTV Tester Rapport III P/N : 388087140 RAPPORT III / Rev.01/1 Feb.2011 PRINTED IN KOREA TABLE OF CONTENTS Information .................................................. 4 Before Using Rapport III ................................ 5 Safety Information .......................................... 6 Product Introduction ....................................... 10 Major functions of Rapport III ........................ 10 Standard item ............................................... 11 TABLE OF CONTENTS Symbols Drawing .................................................. .................................................. Introduction .................................................. 12 Product Specification ..................................... 18 General specification ..................................... 18 Meter specification ....................................... 19 Functional Specification ................................ 20 Power ON/OFF ............................................. 20 ............................................. 21 Mode setup ............................................. 22 Video tester DVR function ............................................. 25 Digital multimeter .......................................... 34 PTZ controller ............................................. 38 UTP cable tester ............................................. 41 02 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 03 43 44 INFORMATION BEFORE USING RAPPORT III General Rappo III is a Portable Service Monitor & Rapport Multim Multimeter with a built-in 3.5 inch digital monitor. It’s a simple and convenient multi-functional s measurement and test tool which provides measu monito monitoring and analytical data when installing CCTV systems s Product Functions Produ Video Input and Output Multim Multimeter (Voltage and Resistance) Cable TTest (UTP) PTZ Co Control Video Storage Function (DVR, Rapport III - PRO) Operat Operating Temperature: -10℃ ~ 50℃ Relative Humidity: 30% ~ 90% Relativ Rechar Recharge Voltage: 12V ±10%, 1.2 A or above *Normal ooperation: Without using DVR and Multimeter General Be sure to read through the "Safety Information" section before using this Rapport III. This basic instruction manual is for users of the Rapport III. Starting with an outline of this Rapport III, the manual explains its operation,how it connects to other devices, how to use the menu buttons,and how it should be operated. It is highly recommended, even for those who have handled similar devices, as well as for those using it for the first time, to read all the instructions thoroughly, especially the precautions, before using the Rapport III. If there are any questions which arise when using the Rapport III or the unit is damaged, please contact the supplier of your Rapport III. Safety Information highlights and explains the precautions which should be taken, for the safety of Users, when using the Rapport III. Introduction to the Rapport III, explains the available features and appearance. Specifications of the Rapport III, explains the specification of the Rapport III. Functional Use, details the functions of the Rapport III and explains their uses. *The Rapport III and Rapport III Pro support the same basic functions, but the Rapport III does not include the DVR function. 04 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 05 SAFETY INFORMATION SAFETY INFORMATION Precautions Precautions The following describes how to safely operate the Rapport III. Please read carefully “the precautions for use of this product” prior to using this device. Check the input and output ranges of any voltages being applied to all inputs and outputs of the device, and ensure their connections have been made properly so no abnormal load is placed on the operation of the device. If the measurement value is unknown when measuring a resistance, set the Rapport III meter to its maximum value so that no abnormal load is placed upon the device. The Rapport III should only be used under the environmental conditions shown in the specification where temperature and humidity figures should be adhered to. Before using the multimeter function for circuit testing, always disconnect all Video In/Out connections made to any other external devices. Connecting the Test Lead Set to a circuit for testing, with these ese connections made, causes them to use a common grounding path and could result in damage to the device. 06 Pay attention to the following precautions when using the Rapport III. Do not use the unit in damp, humid or gaseous environments. Do not touch it with wet hands. Be mindful not to shock or shake the unit while in use to avoid damage. Avoid areas with strong magnetic or electromotive fields, which can cause incorrect measurements or operability. Do not expose the ports or joints to dirt or liquids. Do not disassemble the Rapport III. Do not use the meter function, if the Rapport III or the Test Lead set look damaged. Do not measure resistance when power is applied to a circuit. MONITOR When using the meter function, do not forget to turn on the power to the Rapport III and use the correct measurement range before connecting to a circuit to be measured. Turn off the power to the circuit under test and discharge all high voltage capacitance before starting resistance or continuity tests to avoid damage to the Rapport III. DC POWER SUPPLIES 5 VOLT COM Place fingers behind the protecting pad when using a test probe. + MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 07 SAFETY INFORMATION Precautions Battery Charging Precautions The Rapport III has a built-in Lithium Polymer Battery. It can be recharged using a DC12V power adapter with an output of 1.2A or above and reaches its full charge after a period in excess of 6 hours. After the battery has been fully charged for the first 2~3 charging cycles, it can be used for approximately 6 hours (up to a Max.8 hrs in normal operation). SAFETY INFORMATION Precautions Battery Handling Avoid short circuits, as this will cause internal damage to the battery. The soft packaging can easily be damaged by contact with sharp surfaces or objects, take care when handling or storing. The sealed edge adjacent to the battery contacts is a very sensitive area; take care not to bend or fold the edges. Do not open the folded edges. Do not bend the tabs are these are breakable. The battery can be recharged by connecting it to the DC adapter, regardless of OSD power, when the slider switch has been turned on. Avoid mechanical shocks to the battery. Do not immerse the battery in water. Only use the supplied battery charger or one with a safety guarantee. Stop charging immediately if the battery is overheating, emitting a burning smell, changed in colour or distorted. The discharge operation starts when the Main Switch is turned on and it then consumes power from the battery. Therefore, when the Rapport III is not being used for a period of time, make sure the Main Switch is turned off. Keep away from static electronic fields while using, charging or when storing. Do not disassemble; the battery is not a serviceable item. Never short circuit the positive and negative poles of the battery. Do not charge the battery in ambient temperatures above 40ºC/104ºF. 08 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 09 PRODUCT INTRODUCTION PRODUCT INTRODUCTION Standard Items Power Adaptor UTP Tester Termial Test Lead Set (Red, Black) Safety Strap Rapport III- PRO SD SD Card * SD Card is provided to Rapport III- PRO only. Rapport III Package Bag Tester Carry Bag RA UTP Cable Testing ► Test the integrity of connection conditions of a Category 5e UTP cable. Checks for continuity or short circuits. s M port anu al 10 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER RT PTZ Protocol Analyzer ► It determines which protocol controls a PTZ camera from a PTZ Controller or DVR. This helps the CCTV Installer to understand the protocol and find faulty devices. Rap r’ BNC Video cable O Meter ► Functions for testing voltage, resistance and short circuits. Use User Manual Power Adapter (DC12V) Safety Strap BNC Video Cable PP DVR Function (This funtion is only supported by the Rapport III-PRO) ► Store the video input on to a SD Card and play it back. SD Card (2Gb Storage) - (optional, Rapport III-PRO) Test Lead Set (1 x Red Lead, 1 x Black Lead ) Rechargeable Lithium Polymer Battery (7.4V 2000mA) UTP Test Terminal - Dongle RA Video Testing ► Tests whether a video image is present, and its quality, by displaying the image on the built-in 3.5” Digital Monitor. ► Conducts and displays the Video Level (IRE test) of the image. ► Video signal generator Mode : It outputs a Colour Bar which allows the engineer to test a video monitor or DVR. Rapport III supports both PAL & NTSC video signal format. Rapport III Main Test Unit T Major Functions of Rapport III Check the contents of your Rapport III package against the standard checklist below : OR Designed, with portability and serious CCTV engineers in mind, the Rapport III is an advanced piece of video test equipment consisting of many useful test functions needed to professionally install a CCTV system; test functions include Video Level, Service Monitor, Multimeter, UTP Test, PTZ Test, RS-422 and RS-485 Communication Test, etc. PP Summary 11 PRODUCT INTRODUCTION PRODUCT INTRODUCTION Rapport III (without DVR function) Introduction The Rapport III and Rapport III-Pro support the same basic functions, but the Rapport III does not include the DVR function. BNC Video Input BNC Video Output UTP Input RS-485 In/Out LED Indicator The LED turns Red or Green depend on the recharging status. On charging : RED LED ON Fully charged: GREEN LED ON SD Card Slot When operating the Rapport without an adapter. LED Indicator PTZ Control Pad On operating: RED LED ON Low battery : RED LED flickers on and off Power Input DC12V Power LED Item RED LED Charging mode Test Lead Port Main Power Switch Operating mode GREEN LED Charging ON OFF Fully charged OFF ON Charging error OFF OFF Operating ON OFF Low battery Flicker OFF *This is for power LED status when the power switch is ON. 12 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 13 Remark Adaptor connected Adaptor disconnected PRODUCT INTRODUCTION PRODUCT INTRODUCTION Rapport III Rapport III-Pro Part Name Function ① LCD TFT LCD ② POWER Red LED is on when the OSD POWER is on ③ Data Transmitting LED Red LED is on when Data is Transmitted ④ Data Receiving LED Red LED is on when Data is Received ⑤ Key Button For Controlling External Devices i.e. Rapport III MODE MODE Button Used to Change Setup SET SET Button OSD Selection OSD OSD Button It toggles OSD & POWER on/off FAR Button Adjusts PTZ Focus (Far Direction) & Increases Video Image Brightness NEAR Button Adjusts PTZ Focus (Near Direction) & Decreases Video Image Brightness Part Name Function ① LCD TFT LCD ② POWER Red LED is on when the OSD POWER is on ③ Data Transmitting LED Red LED is on when Data is Transmitted ④ Data Receiving LED Red LED is on when Data is Received MODE MODE Button Used to Change Setup SET SET Button OSD Selection OSD OSD Button It toggles OSD & POWER on/off FAR Button Adjusts PTZ Focus (Far Direction) & Increases Video Image Brightness NEAR Button Adjusts PTZ Focus (Near Direction) & Decreases Video Image Brightness PWR PWR FAR 10 10 NEAR TELE TELE Button WIDE Button WIDE Shift Setup Button ⑥ Key Button Zooms PTZ (Zoom In) & Increases Video Image Contrast Zooms PTZ (Zoom Out) & Decreases Video Image Contrast FAR 10 10 NEAR TELE TELE Button WIDE Button WIDE Shift Setup Button Moves PTZ Up, Down, Right, Left & Also Used for Menu Functions METER ⑥ Key Button OPEN Voltage Button Measures Voltage CLOSE Resistance Button Measures Resistance CLEAR Setup Change Button Changes setup Between AC & DC, Resistance/continuity Test V AC / DC/ FILE FILE REC PLAY Image data list for SD card (Rapport III-PRO) REC Record Video (Rapport III-PRO) PLAY Playback Recoded Video (Rapport III-PRO) ⑦ Test Lead Connection Test Lead Connection Positions COM Position of Black Test Lead, Common Ground (-ve) Zooms PTZ (Zoom In) & Increases Video Image Contrast Zooms PTZ (Zoom Out) & Decreases Video Image Contrast Moves PTZ Up, Down, Right, Left & Also Used for Menu Functions METER Voltage Button Measures Voltage Resistance Button Measures Resistance AC / DC/ Setup Change Button Changes setup Between AC & DC, Resistance/continuity Test IRE IRE V OPEN For Controlling External Devices i.e. Rapport III ⑤ Key Button CLOSE Measures Video Level ⑦ Test Lead Connection Test Lead Connection Positions COM Position of Black Test Lead, Common Ground (-ve) V/ Position of Red test Lead for Measuring Voltage & Resistance (+ve) Position of Red test Lead for Measuring Voltage & Resistance (+ve) V/ 14 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 15 PRODUCT INTRODUCTION PRODUCT INTRODUCTION ① ③ ② ④ ① ② ③ ④ Part Name Function ① Input BNC Input for External Video signal ② Output BNC Outputs the Screen Displayed on the Rapport III, or the Internally Generated Video Test Signals ③ Communication Port Connections for RS422 and RS485 Input & Output (Rx+, RX-, TX+, Tx-) ④ Safety Strap Used to Carry the Rapport III Safely 16 MULTI FUNCTIONAL CCTV TESTER Part Name Function ① DC Power Jack DC Power Input Jack (DC12V, 1.2A) ② Power Switch ON/OFF Main Power Switch ③ UTP RJ45 Jack Test Jack for UTP cable ④ SD Card SD Card Slot (Rapport III-PRO) MULTI FUNCTIONAL CCTV TESTER 17 PRODUCT SPECIFICATION PRODUCT SPECIFICATION Meter Specification General Specification Input Voltage 12V ±10%, above 1.2A Battery Lithium Polymer Battery (Inner packaging) Electrical Characteristics Charging Time More than 6 hrs Operation Time More than 6 hrs (Max.8hrs) Built-in Charger Image PTZ Operation Test TV Type NTSC/PAL Image level 1Vpp, 140 IRE Protocol Multi 2400bps ~ 115.2Kbps Transmission Mode RS-422, RS-485 Tests Continuity/Crossed Cable, and Breaks or Short-Circuit Size DC Voltage AC Voltage Transmission Speed UTP Cable Test Mode W(88mm) X L(126mm) X D(40mm) Resistance Continuity 18 MULTI FUNCTIONAL CCTV TESTER Range Minimum Measuring Accuracy 400mV 100uV ±(2.5% +4dgts) 4V 1mV 40V 10mV 300V 100mV 4V 1mV 40V 10mV 300V 100mV 400Ω 0.1Ω 4㏀ 1Ω 40㏀ 10Ω 400㏀ 100Ω 4㏀ 1㏀ ±(2.0% +4dgts) 40㏀ 10㏀ ±(3.0% +5dgts) ±(2.5% +4dgts) ±(2.5% +4dgts) (40㎐ ~ 500㎐) ±(2.0% +4dgts) ±(2.0% +2dgts) Beeper is activated when the resistance is below 80Ω MULTI FUNCTIONAL CCTV TESTER 19 FUNCTIONAL SPECIFICATION FUNCTIONAL SPECIFICATION Power ON/OFF Mode setup Use a DC12V Power Adapter and connect it to the DC Jack. Turn the Rapport III ON/OFF by using the slider switch located on the side of the product. After switching the power switch to the ON position, press the OSD button and the Rapport III will boot up. To turn the Rapport III OFF, keep the OSD button depressed for at least 2 seconds and wait until a POWER OFF message is displayed on the Main Screen. Release the OSD button and turn off the ON/OFF slider switch; power is now turned off. The OSD menu changes whenever the key is pressed, and sequences through in the following order : VIDEO – METER – PTZ - CABLE - SETUP The MODE SELECT menu is displayed when the key is depressed and moves to the next menu whenever the keyy is pressed p When charging the battery, keep it on charge for more than 6 hours or until the unit is fully charged. On full charge the operational time is approximately 6 hours. (Max.8hrs) If the battery indication shows less than (Full recharge state: ) MODE MODE SETUP LOSS USER NAME : RAPPORT-III SLEEP TIME: 5Min BUZZER : ON you need to recharge the battery. Initial Screen en Display at Power On RAPPORT RAPPORT III FW Version : 0.30 After the power is applied the above on-screen message is displayed. Approximately 2 seconds later the screen switches to the last OSD before power was turned off. The Rapport III stores the last accessed OSD. The initial OSD message displays the Rapport's firmware level. Versions of the product change whenever new firmware is uploaded. 20 MODE MULTI FUNCTIONAL CCTV TESTER VIDEO METER PTZ CABLE SETUP Video Tester Mode : This function displays the image of an externally input video signal, or is used to output internally generated signals when in PATTERN GENERATOR mode. DVR MODE (Rapport III-PRO only) : Used to record (onto SD Card) and playback input video images. Digital Multimeter mode : Tests voltage, resistance, & continuity. PTZ Controller mode : This function allows up, down, right and left movements of a PTZ camera to be made. Also, zoom & manual focus can be adjusted. UTP Cable Tester mode : Tests UTP cable connectivity – tests for straight & crossed cables, for breaks and short circuits. Main Setup mode : This function allows changes to be made to the basic setup of the Rapport III (user name, auto power off time, beeper etc). MULTI FUNCTIONAL CCTV TESTER 21 FUNCTIONAL SPECIFICATION FUNCTIONAL SPECIFICATION VIDEO TESTER Connect the output terminal of video output system to the video input BNC of Rapport III. Connect the video output BNC of Rapport III to the video input terminal of system. Level VIDEO IRE: OSD Screen Setup LOSS C OmV BRIGHT CONTRAST 07 07 MODE COLORBAR VIDEO : Indicat Indicates that the Rapport III is in video test mode. Whene Whenever there is a video input, in video test mode, the vide video level is automatically displayed. CLR On PAL mode, On NTS NTSC mode, the video will be displayed in IRE. the video will w be displayed in mV. BACK VIDEO VIDEO NTSC IRE: B OmV PAL C VIDEO VIDEO NTSC COLOR BAR 07 BRIGHT CONTRAST IRE: B OmV COLOR BAR 07 BRIGHT CONTRAST 07 NTSC C FORMAT CLR BACK Go back to the Video mode 07 FORMAT BACK FORMAT Toggle the video type between NTSC and PAL NTSC CLR CLR Clear OSD Video and Testing : By default the Video will be displayed in the top portion of the screen. If there is no video signal at the VIDEO IN port of the Rapport III /Rapport III-PRO “LOSS” will be displayed. Depending on the type of camera connected to the tester the Video and Sync level will automatically change between IRE (Institute of Radio Engineers) and mV. NTSC signals that are used in North America are measured in IRE units, PAL signals that are common throughout the rest of the world are measured in mV (millivolts) 22 Understanding Video and Sync Level Rapport III / Rapport III PRO measures the combined Luminance and Burst levels of a composite video signal as the Video Level. The Sync signal is embedded between the Luminance and Colour Burst signals. See the following chart for a description of the levels that are expected. MULTI FUNCTIONAL CCTV TESTER PAL Luminance Level 100 ± 10 IRE Colour Burst Level 40 ± 5 IRE Video Level 140 ± 15 IRE Sync Level 40 ± 5 IRE Luminance Level 700 ± 140 mV Colour Burst Level 300 ± 35 mV Video Level 1000 ± 175 mV Sync Level 300 ± 35 mV MULTI FUNCTIONAL CCTV TESTER 23 FUNCTIONAL SPECIFICATION FUNCTIONAL SPECIFICATION The Video Level should be within the indicated range. Levels that are too low will result in a dim picture with reduced dynamic range. A Video Level that is too high will result in washed out pictures with decreased definition. The Sync Level controls the drawing of each line on the monitor. Sync Levels that are too low will cause the picture to breakup or roll while Sync Levels that are too high will result in a picture with reduced grey colours and dynamic range. In an installation with multiple cameras, the video and sync levels should be matched as closely as possible at the head-end to prevent noticeable picture quality differences when switching between cameras on a sigle monitor. Values outside the recommended tolerances can cause the operators to experience eye fatigue. VIDEO : Indicates if the input or output video signal system is NTSC or PAL. Input video signal is output onto the LCD screen and automatically switches to NTSC or PAL without using a special setup key. The output video signal when in Pattern Generator mode can be switched to NTSC or PAL, using the SET key. BRIGHT DVR VIDEO RapportIII-Pro supports the DVR function. NTSC C FILE : 1 DVR SD METER IN PTZ CABLE SETUP 1. Selecting the DVR mode causes the DVR (Rapport III- PRO) to initially boot up and after 2~3 seconds the start menu is displayed. DVR NTSC C DVR NTSC C FILE : 1 DVR Booting... ③ ① SD IN ④ ⑤ ② MODE ⑥ 07 Indicates screen brightness, and brightness increases by +1 when the key is pressed, and decreases by -1 when the key is pressed. It returns to the initial setup value when either of the two keys is depressed for more than 3 seconds. FAR NEAR CONTRAST Introduction to the DVR Function (Rapport III-Pro) ( 07 Indicates screen contrast, and contrast increases by +1 when the key is pressed, and decreases by -1 when the key is pressed. It returns to the initial setup value when either of the two keys is depressed for more than 3 seconds. TELE WIDE 24 MULTI FUNCTIONAL CCTV TESTER ① DVR MODE : Indicates DVR Mode. ② NTSC : Indicates NTSC or PAL System. ③ Indicates Screen Mode. Shows REC (●) when in record and PLAY (▶) when in playback, otherwise will display LIVE for real time images. ④ FILE NO : Idicates recoded file number. ⑤ EMPTY : No SD card installed. IN : SD card has been installed. ⑥ MODE : Change the mode. MULTI FUNCTIONAL CCTV TESTER 25 ) FUNCTIONAL SPECIFICATION FUNCTIONAL SPECIFICATION 2. Basic Operation PTZ MODE 1) Video Storing Function LOSS C PTZ ADDR :001 PROTOCOL : (01)PELCO-D BAUDRATE:19.2Kbps PARITY : NONE SPD GPST SPST 15 001 001 SETUP FUNC 01 MENU DATA Recording video : Support 8 files with 10minute each. DVR NTSC C FILE : 2 - Input SD card: Input a SD card pre-formatted to a FAT32 format. SD card slot SD IN OSD changes EMPTY IN MODE - Remove SD card : Remove the SD card after power off or move to another mode and remove it. - Select file number. (EX. FILE 2) - Lock SD card : When the SD card is locked, recording and playback functions are not supported. Press the DVR DVR NTSC C FILE : 1 SD NTSC C FILE : 1 IN DVR EMPTY button to stop recording. NTSC C FILE : 2 REC DVR Designate the file storage location using the Up & Down buttons. Pressing the REC button starts the recording process and REC is displayed. SD IN 00:00 NTSC C FILE : 1 SD LOCK MODE MODE MODE SD CARD IN SD CARD OUT MODE SD CARD LOCK Button Key for DVR function Record DVR NTSC C FILE : 2 SET : Confirm the setting of each function (=ENTER key). DIRECTION KEY ( ) :Set the file, speed of playback. STOP( ) : Stop recording & playback. FILE : To check the recorded video file. CLEAR : Delete the recorded video. REC : Record the video image. PLAY : Playback the recorded video. 26 MULTI FUNCTIONAL CCTV TESTER SD IN UPDATE FILE : 2 YES NO There is a option for recording a video file. Press the REC button and "UPDATE FILE" is displayed. Select YES and press the SET button to start video recording. MODE ※ If another video clip has already been stored in the selected file location the message "UPDATE FILE" is displayed. The existing file is deleted and the location updated with the new video clip when the quick menu is selected. MULTI FUNCTIONAL CCTV TESTER 27 FUNCTIONAL SPECIFICATION FUNCTIONAL SPECIFICATION 2) Video Playback 4) Check Recorded File DVR NTSC C FILE : 2 SD DVR IN NTSC C FILE : 2 SD IN Shows the SD Card files, and their recorded file size. DVR SD CARD MODE NTSC C FILE INFORMATION FILE1 : 12MB FILE5 : FILE2 : 19MB FILE6 : FILE3 : FILE7 : FILE4 : FILE8 : MODE MODE - Designate the file storage location by using the Up & Down keys and press the PLAY button. The play mode ( ▶ ) is shown with the video. To stop playback press the button. - Use the Left and Right keys Options are 2x, 4x, 8x or 16x . to adjust playback speed. 3)Delete Recorded File DVR NTSC C FILE : 2 SD DVR IN NTSC C FILE : 2 SD IN CLEAR FILE : 2 YES MODE Press the button, Select YES or No using the delected. NO MODE is shown on the LCD Screen with a Clear File message. keys and press the SET button. The recorded file is * CL E A R F I L E : 5 YES NO The file deletion can be checked by pressing the FILE button (If the file has been deleted, "Empty" is displayed). 28 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 29 FUNCTIONAL SPECIFICATION How to playback the video file on a PC FUNCTIONAL SPECIFICATION 3. Installation (Setup) Please contact the manufacturer or your local agent to obtain the download details for the Rapport III-Pro PC playback software program. Supported PC spec. & O/S ITEM Min. Requirements Recommended Specifications CPU Pentium III 800 Above Pentium IV 2.0G Main Memory 256 MB Above 256MB O/S* Windows 2000 Window 2000 or XP, VISTA, WINDOWS 7 Web Browser I.E 5.0 Above I.E 5.0 Resolution 1,024 X 768 1,152 X 864 Network 100Base - T Ethernet 100Base - T Ethernet 2. Supported O/S ① Select language => Click NEXT ② Setup the program ③ License => Select agree ④ Setup Status Windows 2000 Professional Windows XP Windows 2000 Server Windows VISTA Windows 7 (32 bit only) ⑤ Setup Complete => Click Finish button 30 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 31 FUNCTIONAL SPECIFICATION FUNCTIONAL SPECIFICATION Precautions 4. AKR Player Screen You will find the icon on your PC desktop after program set up. Insert SD Card as shown in the picture. Click the icon and AKR Play Screen starts. Click the icon and find the video file you want. ① ② ④ ⑤ ► Please make sure power is off before inserting the SD Card. ► The SD Card label should be on the reverse side when inserted into the Rapport III-Pro. ► The SD Card could be damaged if incorrectly inserted. SD Insert SD card ③ ① Select file. ② Click the file. ③ The file will playback. ④ Use the right mouse button to define the image size. 32 MULTI FUNCTIONAL CCTV TESTER MULTI FUNCTIONAL CCTV TESTER 33 FUNCTIONAL SPECIFICATION FUNCTIONAL SPECIFICATION Description of Meter Function LCD Window WARNING 1. DO NOT unplug the SD card during recording. 2. Stop recording or playback before powering off the system. 3. DO NOT use the DVR function when there's a Low Battery warning. LOSS OHM VOLT BUZZ ① METER DC AC ② DCV -0.000V ⑥ ④ ⑤ DCV--0.001V MODE STORE Digital Multimeter Voltage, resistance and continuity can be tested. WARNING To prevent electric shocks, injury, or damage to the Rapport III, disconnect the power supply to the circuit under test, and discharge all high-voltage capacitors before testing resistance and continuity. When using the meter function of the Rapport III, make sure the unit is switched on and set to the appropriate test mode before connecting the test lead set to the circuit under test. Setup Keys Press the button to measure resistance; pressing the / / button changes from the OHM scale to BUZZER (for continuity testing). CLOSE CLEAR Part Function ① Type of Test Set Up ② Test value Displayed ③ Measured Graph Value ④ Measured Value on Hold ⑤ MODE Display Description - Resistance Test - Continuity Test - DC and AC Voltage - Unit of resistance Test - Indicates either the AC or DC Voltage Range - AC Voltage is indicated as RMS (Root Mean Square) Values - The Measured Input value is Displayed in the Form of a Graph - The Graph is Changed Automatically and is Equal to the Measured Value - OVER is Displayed When the Measured Value is Higher Than the Setup Value The Measured Value is Stored and Displayed Here When the SET Key is pressed Digital Multimeter Mode is displayed AC DC Press the button to measure voltage; pressing the / / button causes the measurement range to toggle between ACV and DCV. OPEN CLEAR AC DC V 34 MULTI FUNCTIONAL CCTV TESTER ⑥ DC DC Voltage Test AC AC Voltage Test OHM Resistance Test ( Measuring Unit : Ω ) VOLT Voltage Test ( Measuring Unit : V ) BUZZ Continuity Test ( Starts to beep when below 80Ω ) MULTI FUNCTIONAL CCTV TESTER 35 FUNCTIONAL SPECIFICATION FUNCTIONAL SPECIFICATION Measuring Resistance The unit of resistance is the Ω. The meter sends a low current into the circuit so that the resistance can be measured. This current runs along all paths between the two probes and enables the total resistance to be calculated. How to measure : Connect the red lead to and the black lead to , as shown in the figure to the left, and measure the resistance and measure the resistance directly. 3 3 3 METER DC AC LOSS C OHM VOLT BUZZ OHM OVER MODE STORE Measuring AC & DC Voltage Voltage is the difference in electrical potential between two points. The polarity of an AC voltage varies with time, while DC polarity is constant. The meter displays AC voltage as RMS values (root mean square readings). The RMS value is the equivalent DC voltage measured in a time varying sinusoidal signal. METER DC AC LOSS C OHM VOLT ACV 0.018V METER BUZZ DC LOSS C AC OHM VOLT BUZZ DCV+ 12.23mV Continuity Testing Continuity means the presence of a complete path for current to flow. The continuity test features a beep that sounds when a circuit is complete. The beep allows users to quickly test continuity without having to watch the display. How to test : Resistance mode changes to continuity mode, OHM OVER OHM OVER when the is pressed. The beeper is activated when the resistance between the red and black probes is less than 80Ω. METER DC AC MODE LOSS C OHM VOLT METER BUZZ DC STORE OHM VOLT 3 MODE STORE 36 3 STORE 3 3 3 3 3 STORE 3 3 MODE BUZZ 3 3 STORE LOSS C AC MODE 3 MODE Change Mode Fix and show the current value. MULTI FUNCTIONAL CCTV TESTER How to measure : Press the voltage measuring button, and then select AC or DC by pressing the button. When DCV is being measured, place the red lead on +ve side and the black lead on -ve side of the voltage source. MULTI FUNCTIONAL CCTV TESTER 37 FUNCTIONAL SPECIFICATION FUNCTIONAL SPECIFICATION PTZ Controller How to Control a PTZ Camera How to connect each terminal and LCD screen PTZ Operation Test : Performs basic operational PTZ movements; Up, Down, Left, Right, Zoom, and Manual Focus. It also tests various protocols and their transmission speeds. In order to control a PTZ, connect the PTZ communications cables to TX terminals of the Rapport III. PTZ LOSS C PTZ ADDR :001 PROTOCOL : (01)PELCO-D BAUDRATE:19.2Kbps PARITY : NONE SPD GPST SPST 15 001 001 MODE FUNC 01 SETUP Function Setup of the PTZ Use the SETUP keys to adjust GPST / SPST / FUNC / SPD and MENU settings (displayed on the lower part of the LCD screen) by pressing the SET key once. GPST (GO TO PRESET) : Moves the camera view to a designated preset location; Presets are numbered 000 to 255. The cursor moves to the GPST position when the key is pressed. Select the previously stored PRESET number using the & keys (move by+1, -1 step). Once selection is complete, press the key once more and the camera will move to the PRESET location. SPST (SET PRESET) : Sets and stores PRESET information in the range from 000 to 255. First, move the camera to the required view and press the key, and use the & keys to place the cursor at the location of the chosen preset. Then set up the address where the preset is to be stored by using the & keys, and press the key once more. The location information is now stored as a preset address. SET MENU RxRx+ DATA PTZ PTZ functions - Up, Down, Left, Right movements are carried out using the SETUP Buttons. Focus and Zoom adjustments are made using the FAR/NEAR (Focus) and TELE/WIDE (Zoom) buttons. - PTZ Control Setup Screen LOSS C Pressing this button displays the received PTZ data. DATA @Receive Data SET SET SET BACK CLEAR SET PTZ LOSS C PTZ ADDR :001 PROTOCOL : (01)PELCO-D BAUDRATE:19.2Kbps PARITY : NONE SPD GPST SPST 15 001 001 MODE FUNC 01 PTZ MENU OK MODE ADD Setup Screen PTZ LOSS C PTZ ADDR :001 PROTOCOL : (01)PELCO-D BAUDRATE:19.2Kbps PARITY : NONE SPD GPST SPST 15 001 001 FUNC 01 MENU OK Protocol Setup Screen LOSS C PTZ ADDR :001 PROTOCOL : (01)PELCO-D BAUDRATE:19.2Kbps PARITY : NONE SPD GPST SPST 15 001 001 MODE FUNC 01 MENU OK Communications Speed Setup Screen - Keyboard Controller Code Screen. PTZ LOSS C @Receive Data BACK - The controlling protocol from the keyboard or the DVR is displayed on this screen. More important, however is that the communications speeds are matched. CLEAR FUNC : Follows the FUNC set up using the SPST and MENU information. The Setup range is from 00 to 63. It can be set by +1, -1 step by using the & keys. SPD (SPEED) : Move the cursor to the SPD icon, using the procedures described above. A total of 16 increments in speed (1 to 16) are available for selection using the & keys. MENU : Place the cursor at the MENU location, using the procedures described above. The MENU of the PTZ can be displayed on LCD screen, using the key. SET ※ When set the above funtions, it can be set by +10, -10 steps by using the 38 MULTI FUNCTIONAL CCTV TESTER FAR , NEAR keys. MULTI FUNCTIONAL CCTV TESTER 39 FUNCTIONAL SPECIFICATION FUNCTIONAL SPECIFICATION CAUTION UTP CABLE TESTER 1. Make sure to check the communication protocol, transmission speed, and PTZ ID. 2. The input signal from the controller can be checked when the communication line is connected to the Rx terminal of the Rapport III. MODE CABLE Control Setup of PTZ The PTZ ADDR menu bar is accessed, on the top section of the LCD screen, when the key is depressed for more than 3 seconds. The activated menu can be changed to PROTOCOL and BAUDRATE by pressing the & keys. LOSS TEST NO CONNECTION Change the mode Check the cable type by pressing the SET button. SET PTZ PTZ ADDR : Setup the PTZ ID. The default value is 001. To change the PTZ ID use the & keys and it moves by +1, -1 steps. The available values are 001 through to 255. PROTOCOL : Used to set the PTZ PROTOCOL. The default value is set to PELCO-D. To change to another protocol, use the & keys to see the available protocols. keys. BAUDRATE : Sets the TRANSMISSION SPEED. The default value is 2.4Kbps. Use the & keys to alter the speed – the available options are from 2.4Kbps~ 115.2Kbps. PARITY : Set the parity to NONE, ODD and EVEN by using & keys. PTZ MENU Connect the UTP cable to be tested to the UTP port of the Rapport III, and connect the other end of the cable to the yellow UTP test dongle. LOSS C FUNC 01 MENU OK PTZ Once the connection is complete, the connectivity of the cable under test is checked by pressing the SET key. Straight through and crossed cables can be verified. Disconnections and short-circuits are also displayed. LOSS C PTZ ADDR :001 PROTOCOL : (01)PELCO-D BAUDRATE:19.2Kbps PARITY : NONE SPD GPST SPST 15 001 001 MODE FUNC 01 OK PTZ ADDR :001 PROTOCOL : (01)PELCO-D BAUDRATE:19.2Kbps PARITY : NONE SPD GPST SPST 15 001 001 MODE CABLE FUNC 01 MENU (1) XXXXX (X) (2) XXXXX (x) (3) XXXXX (X) (4) XXXXX (X) MODE Check the CAMERA ID, PROTOCOL and BAUDRATE settings prior to testing. A PTZ camera cannot be controlled unless all three settings are correct. 40 MULTI FUNCTIONAL CCTV TESTER CABLE LOSS CABLE LOSS STRAIGHT (5) XXXXX (X) (6) XXXXX (x) (7) XXXXX (X) (8) XXXXX (X) (1) (2) (3) (4) (1) (2) (3) (4) CROSS (5) (6) (7) (8) (5) (6) (7) (8) (1) (2) (3) (4) (3) (5) (7) (1) (5) (6) (7) (8) MODE TEST TEST MODE TEST LOSS C PTZ ADDR :001 PROTOCOL : (01)PELCO-D BAUDRATE:19.2Kbps PARITY : NONE SPD GPST SPST 15 001 001 MODE LOSS NO CONNECTION OK PTZ CAUTION TEST LOSS C PTZ ADDR :001 PROTOCOL : (01)PELCO-D BAUDRATE:19.2Kbps PARITY : NONE SPD GPST SPST 15 001 001 MODE MODE Short-circuit & Disconnection FUNC 01 Straight cable Cross cable MENU OK MULTI FUNCTIONAL CCTV TESTER 41 (2) (4) (6) (8) FUNCTIONAL SPECIFICATION SETUP SETUP Mode Select : To access this menu depress the MODE key and select the SETUP icon. LOSS USER NAME : RAPPORT-III SLEEP TIME: 5Min BUZZER VIDEO : ON METER SETUP PTZ CABLE SETUP Select a menu item by pressing the & keys. Each setup value can be changed by pressing the & keys SETUP SLEEP TIME: 5Min BUZZER : ON Description 1 IRE 60417 - 5031 Direct current 2 IRE 60417 - 5032 Alternating current 3 IRE 60417 - 5033 Both direct and alternating current 4 3 Three-phase alternating current 6 IRE 60417 - 5019 PROTECTIVE CONDUCTOR TERMINAL 7 IRE 60417 - 5020 Frame or chassis TERMINAL 8 IRE 60417 - 5021 Equipotentiality 9 IRE 60417 - 5007 On(Supply) SLEEP TIME: Select sleep time by using the & buttons. The options are OFF, 1, 5, 10, 30, 60 minutes. 10 IRE 60417 - 5008 Off(Supply) 11 IRE 60417 - 5172 Equipment protected throughout by DOUBLE INSULATION or REINFORCED INSULATION BUZZER: Select ON/OFF by using the & buttons. 12 CLEAR LOSS USER NAME : RAPPORT-III Reference Earth (ground) TERMINAL 0123456789()ABCDEFGHIJKLM NOPQRSTUVWXYZ!@#$% & +-+<> STORE Symbol IRE 60417 - 5017 RAPPORT III BACK Number 5 Selecting the USER NAME initiates an editing menu and shows the associated key strokes. LOSS USER NAME TABLE 1 - SYMBOLS 13 Caution, rick of electronic shock IRE 60417 - 5041 Caution, hot surface MODE SLEEP TIME makes the power go OFF automatically, unless button is pressed. MULTI FUNCTIONAL CCTV TESTER 42 **The equipment shall not be used for measurements of categories II, III and IV. **If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. MULTI FUNCTIONAL CCTV TESTER 43 DRAWING (mm) MULTI FUNCTIONAL CCTV TESTER MEMO 44 MULTI FUNCTIONAL CCTV TESTER 45