Transcript
RoHS Compliant
Gigabit Ethernet LC Bi-directional SFP Transceiver (120km) RBT12SVX
Applications
Gigabit Ethernet (1000BASE-BX10) 1X Fiber Channel
Features RoHS compliant Bi-directional GbE single / multi-rate optical data links over single fiber Compliant with SFP MSA Digital diagnostic SFF-8472 compliant Compliant with IEEE802.3ah 1000BASEBX10 PMD specifications other than transmitter output power and sensitivity 1490nm DFB laser transmitter for uplink/ 1590nm DFB laser transmitter for downlink InGaAsP APD receiver for high sensitivity Very low jitter Metal package for lower EMI Single power supply voltage: +3.3V Low power dissipation LC diplexer connector Three optional operating temperature ranges Option ST : -5°C to 75°C Option ET : -10°C to 85°C Option IT : -40°C to 85°C
Description OE Solutions’ Small Form Factor Pluggable (SFP) transceivers are compatible with the Small Form Factor Pluggable 20pin MultiSource Agreement (MSA). RBT12SVX complies with Gigabit Ethernet as specified in IEEE 802.3ah 1000BASE-BX10 other than optical output power and receiver sensitivity to transmit signals longer reach, Fast Ethernet and Fiber Channel FC-PI 13.0. Digital diagnostics functions are available via the 2-wire serial bus specified in the SFF-8472 rev.10.4. The transmitter features ac-coupled differential data inputs, and an LVTTL for Tx disable input and Tx fault output. The receiver features differential ac-coupled data outputs and LVTTL for LOS (Loss of Signal) output. Circuit ground is internally isolated from frame ground.
Rev. A.2, 02/17/2011
RBT12SVX LC Bi-directional SFP Transceiver Product Specifications
1. General Operating Conditions Parameter
Symbol
Min.
Typ.
Max.
Unit
Notes
Vcc_max
0
-
4.0
V
-
Operating Voltage
Vcc
3.135
-
3.465
V
-
Total Current
Icc
-
-
500
mA
-
Operating Case Temperature
Top
-40
-
85
°C
1,2
Storage Temperature
Tst
-40
-
85
°C
-
Absolute Supply Voltage
Notes:
1. Measured on top side front center of SFP module. 2. There are three options of operating maximum temperature: Option ST: standard temperature from -5oC to 75oC, Option ET: extended temperature from -10oC to 85oC and Option IT: Industrial temperature from 40oC to 85oC.
2. Transmitter Specifications (Over Operating Case Temperature Range, Vcc = 3.135V to 3.465V) Electrical Characteristics Parameter
Symbol
Min.
Typ.
Max.
Unit
Notes
B
-
1.25
-
Gb/s
-
Rin
-
100
-
Ω
-
Vin,pp
100
-
1000
mV
-
Tx Disable Voltage
Vd
2.4
-
-
V
-
Tx Enable Voltage
Ven
-
-
0.8
V
-
Optical Power
Pout
-1
-
4.0
dBm
1
Optical Extinction Ratio
ER
9
-
-
dB
-
1460
1490
1520
1560
1590
1620
tr/tf
-
-
260
ps
2
SMSR
30
-
-
dB
-
σ20
-
-
0.88
nm
-
-
-
-
-45
dBm
-
RIN
-
-
-113
dB/Hz
-
Deterministic Jitter
DJ
-
-
80
ps
-
Total Jitter
TJ
-
-
227
ps
-
Transmitter Output Eye
Compliant with Eye Mask Defined in IEEE802.3ah standard
Bit rate Input Differential Impedance Single Ended Data Input Swing
Optical Characteristics
Optical
Up Link
Wavelength
Down Link
Optical Rise/Fall Time Side Mode Suppression Ratio Spectral Width (-20dB) Transmitter off Output Power Relative Intensity Noise (OMA12RIN)
Notes:
λ
-
nm
-
1. Using 9/125 SMF 2. Unfiltered, 20%~80% values
Laser Safety: All transceivers in this datasheet are Class I Laser products per FDA/CDRH and IEC-825 standards. They must be operated under specified operating conditions. 1
Rev. A.2, 02/17/2011
RBT12SVX LC Bi-directional SFP Transceiver Product Specifications
3. Receiver Specifications (Over Operating Case Temperature Range, Vcc = 3.135V to 3.465V) Electrical Characteristics Parameter
Symbol
Min.
Typ.
Max.
Unit
Notes
B
-
1.25
-
Gb/s
-
Vout,pp
200
-
600
mV
-
tr/tf
-
-
260
ps
1
RSENS
-
-
-32
dBm
2
Pmax
-7
-
-
dBm
-
1460
1490
1520
nm
-
1560
1590
1620
nm
-
-
-
-
-12
dB
-
LOS Assert
LOS_A
-45
-
-
dBm
-
LOS De-assert
LOS_D
-
-
-32
dBm
-
LOS Hysteresis
-
0.5
2
5
dB
-
Deterministic Jitter
DJ
-
-
170
ps
-
Total Jitter
TJ
-
-
266
ps
-
Dispersion Penalty
DP
-
-
2
dB
-
Bit rate Single Ended Data Output Swing Data Output Rise/Fall Time Optical Characteristics
Average Rx Sensitivity Maximum Input Power (Overload) Wavelength
Down Link Up Link
Receiver Reflectance
Notes:
λc
1. 20%~80% values 2. Measured with a PRBS of 27-1 at 1 x 10-12 BER, and 9.0 dB extinction ratio at 1490nm or 1550nm.
4. Pin Descriptions SFP Transceiver Electrical Pad Layout 20
Tx GND
1
Tx GND
19
TD-
2
Tx Fault
18
TD+
3
Tx Disable
17
Tx GND
4
MOD-DEF(2)
16
VccT
5
MOD-DEF(1)
15
VccR
6
MOD-DEF(0)
14
Rx GND
7
Rate Select
13
RD+
8
LOS
12
RD-
9
Rx GND
11
Rx GND
10
Rx GND
Top of Board
Bottom of Board
2
Rev. A.2, 02/17/2011
RBT12SVX LC Bi-directional SFP Transceiver Product Specifications
5. Pin Descriptions (continued) Plug Seq. * 1
Notes
Transmitter Fault Indication
3
2
Tx Disable
Transmitter Disable
3
3
4
MOD-DEF2
Module Definition 2
3
4
5
MOD-DEF1
Module Definition 1
3
4
6
MOD-DEF0
Module Definition 0
3
4
7
Rate-Select
No User Connection
3
5
8
LOS
Los of Signal
3
6
9
Rx GND
Receiver Ground
1
1
10
Rx GND
Receiver Ground
1
1
11
Rx GND
Receiver Ground
1
1
12
RD-
Receiver Negative Data Out
3
-
13
RD+
Receiver Positive Data Out
3
-
14
Rx GND
Receiver Ground
1
1
15
VccR
Receiver Power
2
3.3V±5%
16
VccT
Transmitter Power
2
3.3V±5%
17
Tx GND
Transmitter Ground
1
1
18
TD+
Transmitter Positive Data In
3
-
19
TD-
Transmitter Negative Data In
3
-
20
Tx GND
Transmitter Ground
1
1
Pin
Symbol
Description
1
Tx GND
Transmitter Ground
2
Tx Fault
3
1
*Plug Seq.: Pin engagement sequence during hot plugging Notes: 1. Circuit ground is internally isolated from frame ground. Tx GND and Rx GND may be internally isolated within the TRx module. 2. Tx Fault is an open collector output that shall be pulled up with a 4.7kΩ ~ 10kΩ on the host board. Pull up voltage between 2.0V and VccT + 0.3V. When high, output indicates a laser fault of some kind. When low, output indicates normal operation. The LD output is not turned off in case of Tx Fault 3. Tx Disable is an input that is used to shut down the transmitter optical output. It is pulled up within the TRx with a 4.7kΩ ~ 10kΩ. 4. MOD-DEF 0, 1, 2 are the SFP module definition pins. They should be pulled up with a 4.7kΩ ~ 10kΩ on the host board. The pull-up voltage shall be VccT. MOD-DEF0 indicates that the module is present. MOD-DEF1 is the clock line of 2-wire serial interface for serial ID MOD-DEF2 is the data line of 2-wire serial interface for serial ID 5. OE Solutions RBT12SVX SFP transceivers operate at SONET /SDH data rates, 1x Fiber Channel, Gigabit Ethernet and Fast Ethernet data rates, and respective protocols without active control. 6. LOS is an open collector output. Shall be pulled up with a 4.7kΩ ~ 10kΩ on host board. Pull up voltage between 2.0 and VccR+0.3. Logic 0 indicates normal operation.
3
Rev. A.2, 02/17/2011
RBT12SVX LC Bi-directional SFP Transceiver Product Specifications
6. Outline Drawings Dimensions are in millimeters (inches)
4
Rev. A.2, 02/17/2011
RBT12SVX LC Bi-directional SFP Transceiver Product Specifications
7. PCB layout and Bezel recommendation Dimensions are in inches (millimeters).
Notes:
1. Datum and basic dimensions established by customer. 2. Pads and vias are chassis ground, 11 locations 3. Thru holes, plating optional.
5
Rev. A.2, 02/17/2011
RBT12SVX LC Bi-directional SFP Transceiver Product Specifications
8. PCB layout and Bezel recommendation (continued)
Notes: Thru holes, plating optional.
Recommended Panel Opening 6
Rev. A.2, 02/17/2011
RBT12SVX LC Bi-directional SFP Transceiver Product Specifications
9. Power Supply Information 1 µH VccT 0.1µ 0.1µF 1µH 3.3V
VccR 0.1µ 0.1µF
10µ 10µF
0.1µ 0.1µF
10µ 10µF
HOST BOARD SFP MODULE
Recommended Host Board Supply Filtering Network
SFP Host Board Schematic
7
Rev. A.2, 02/17/2011
RBT12SVX LC Bi-directional SFP Transceiver Product Specifications
10. Diagnostics A2h address
Parameter
Calibration
Accuracy
Range
o
96-97
Temperature
External
+/- 3 C
Note 1
98-99
Vcc
External
+/- 3%
3.13 to 3.47
100-101
Tx bias
External
+/- 10%
Note 2
102-103
Tx power
External
+/- 3dB
-1 to 4 dBm
104-105
Rx Power
External
+/- 3dB
-32 to -7 dBm
Note: 1) Junction temperature of temperature sensing device. 2) Specified by nominal value
13. Ordering Information Model Name RBT12SVX-ST4 RBT12SVX-ET4
Operating Temperature
Nominal Wavelength
-5oC to 75oC -10oC to 85oC -40oC to 85oC -5oC to 75oC
RBT12SVX-IT4 RBT12SVX-ST5
-10oC to 85oC -40oC to 85oC
RBT12SVX-ET5 RBT12SVX-IT5
Optical Power Budget
Distance
1490nm
Latch Color Violet
31dB
120Km
1490nm
Violet
31dB
120Km
1490nm
Violet
31dB
120Km
1590nm
Red
31dB
120Km
1590nm
Red
31dB
120Km
1590nm
Red
31dB
120Km
Revision history
Date
Rev. #
Description
Author
09/11/2009
Rev. A.0
first release
JSYU
08/31/2010
Rev.A.1
new SFP master, min LOS assert at -45dBm
JSYU
02/17/2011
Rev.A.2
Photo changed new one.
JSYU
Contact Information: OE Solutions Co. Ltd. (Korea) Techno Park, 958-3, Daechon-Dong, Buk-Gu, Gwangju, Korea, 500-470. Tel: +82-62-602-7813, Fax: +82-62-602-7639, www.oesolution.com.
OE Solutions America, Inc.
560 Sylvan Avenue, 1st Floor, Englewood Cliffs, NJ 07632 Tel: 201-568-1188, Fax:201-568-1177
8
Rev. A.2, 02/17/2011