Preview only show first 10 pages with watermark. For full document please download

Rcp2 Rca-sra / W W W . I N T E L L...

   EMBED


Share

Transcript

ROBO Cylinder Short Length Type RCP2/RCA-SRA www.intelligentactuator.com We have reduced the length by a maximum of 45% compared to the existing model 1 Significantly shortened length We have shortened the length of the actuator by up to 129mm compared to the current equivalent model. (*1) Customers can now use the actuator in narrow locations where there is very little space. (*1) Compared to RCA−RA3C � Length Comparison with Existing Model Compared to RCA-RA3C Compared to RCA-RA3R (   ) (   ) RCA-RA3C 50 stroke RCA−RA3R 50 stroke 50 50 (   ) (   ) 50 50 RCA-SRA4R 50 stroke 1 RCA−SRA4R 50 stroke Shortened by 129mm Shortened by 63.5mm 2 Choose between a pulse motor or servo motor Select between 2 types of motors: a Pulse motor: RCP2 Series pulse motor type suitable for push force and low-speed raising and Usage lowering operations, or a servo motor Low-speed raising and lowering operations, such as clamping and press fitting Servo Motor: RCA Series Us a g e Positioning during high-speed transfer type effective for stable transportation during high-speed operations 3 A guide type can be selected A guide type can be selected if a load is applied to the end of a rod, or if a straight motion is required. A single guide or a double guide can be selected, and for the single guide, there are 3 directions that it can be Single guide Installed on left Single guide Installed on bottom Single guide Installed on right Double-guide installed. 4 Flexible Installation method There are 5 installation surfaces on the actuator. We have also prepared optional front and rear flanges and foot brackets (bottom, side). Flange (Installed on front) Flange (Installed on rear) Foot bracket (Installed on bottom) Foot bracket (Installed on side) � Example of use Used to raise and lower the stopper Used with a clamp 2 � Product & Specification List List � Product & Specification Series Name Series Motor Name type Motor type Type MaximumMaximum load capacity (*) load capacity (*) Ball screw Ball screw MaximumMaximum Maximum Maximum speed Rated speed thrust Rated thrust lead lead pushing force pushing force Horizontal HorizontalVertical Vertical Stroke Stroke Type Standard Standard (no guide)(no guide) With With Pulse motor Pulse motor single guide single guide 35� RCP2 RCP2 35� With With double guide double guide 5 5 250 250 — — 10 to 25 10 to 25 2 to 9 90 90 2.5 2.5 125 125 — — 30 to 35 30 to 35 3 to 15 3 to 15 170 170 5 5 250 250 — — 90 90 2.5 2.5 125 125 — — 30 to 35 30 to 35 3 to 15 3 to 15 170 170 5 5 250 250 — — 90 90 2.5 2.5 125 125 — — 30 to 35 30 to 35 3 to 15 3 to 15 170 170 5 250 250 41 41 9 9 3 3 — — 2.5 2.5 125 125 81 81 18 18 6.5 6.5 — — 5 5 250 250 41 41 9 9 2 2 — — 2.5 2.5 125 125 81 81 18 18 5.5 5.5 — — 5 5 250 250 41 41 9 9 2 2 — — 2.5 2.5 125 125 81 81 18 18 5.5 5.5 — — 9 to 24 9 to 24 1 to 8 9 to 24 9 to 24 1 to 8 2 to 9 1 to 8 1 to 8 20 to 200mm 20 to 200mm 5 20 to 100 are 20 to 100 are set every 10mm. set every 10mm. Standard Standard (no guide)(no guide) 100 to 200100 areto 200 are set every 50mm. set every 50mm. With With Servo Motor Servo Motor single guide single guide 20W RCA RCA 20W With With double guide double guide � Model description � Model description Pulse motor type type Pulse motor RC PRC 2 P2 Series Series I Type Type I SRA4R I 3 5 P3 5 P P1 P1 Encoder type Motor type Motor typeBall screw lead Encoder type Ball screw lead Stroke Incremental I Incremental 5 5mm5 5mm 2.5 2.5mm 2.5 2.5mm Compatible Compatible Controllers Controllers Cable lengthCable length Option Stroke P1 PCON/RPCON PCON/RPCON P1 PSEL PSEL ReversingReversing Type Type SRA4R Short RodShort Type Rod Type ReversingReversing Type Type Short RodShort Type Rod Type SRGS4R SRGS4R with Single Guide with Single Guide 20 20mm 20 to toto ReversingReversing Type Type Short RodShort Type Rod Type SRGD4R SRGD4R with Double withGuide Double Guide35P 200 20mm Option B BrakeB (*) Brake (*) FL Flange (front) FL bracket Flange bracket (front) FLR Flange (rear) FLRbracket Flange bracket (rear) FT FootFT bracket Foot bracket FT2 Foot bracket on right) Foot bracket (Mounted on right) FT2 (Mounted N No cable N No cable FT4 Foot bracket on left)(Mounted on left) FT4 (Mounted Foot bracket P 1m P 1m GS2 SingleGS2 guide, mounted on right Single guide, mounted on right 35P35P pulse 35P motor, 35 motor, size    20 to 100 aretoset 10mm. pulse 35 size    20 100every are set every 10mm.S 3m S 3m GS3 SingleGS3 guide, mounted bottom Single on guide, mounted on bottom M 100 to 200100 aretoset 50mm. 200every are set every 50mm. 5m M 5m GS4 SingleGS4 guide, mounted on leftmounted on left Single guide, NM Reversed-home NM specification Reversed-home specification to 200mm 200 200mm X Length X Designation Length Designation *The brake *The specification can only becan usedonly withbeaused 70mm or higher brake specification with a 70mmstroke. or higher stroke. Ser vo Motor TypeType Ser vo Motor RC ARC A Series Series I Type Type I SRA4R I 20 20 A1 A1 Encoder type Motor type Motor typeBall screw lead Encoder type Ball screw lead Stroke Incremental I Incremental 5 5mm5 5mm 2.5 2.5mm 2.5 2.5mm Compatible Compatible Controllers Controllers Cable lengthCable length Option Stroke A1   ACON/RACON ACON/RACON A1 ASEL   ASEL ReversingReversing Type Type SRA4R Short RodShort Type Rod Type ReversingReversing Type Type Short RodShort Type Rod Type SRGS4R SRGS4R with Single Guide with Single Guide 20 20mm 20 to toto ReversingReversing Type Type Short RodShort Type Rod Type SRGD4R SRGD4R with Double withGuide Double Guide20 200 Servo 20WMotor 20W 20Motor Servo 20mm Option B BrakeB (*) Brake (*) FL Flange (front) FL bracket Flange bracket (front) FLR Flange (rear) FLRbracket Flange bracket (rear) FT FootFT bracket Foot bracket FT2 Foot bracket on right) Foot bracket (Mounted on right) FT2 (Mounted N No cable N No cable FT4 Foot bracket on left)(Mounted on left) FT4 (Mounted Foot bracket P 1m P 1m GS2 SingleGS2 guide, mounted on right Single guide, mounted on right 20 to 100 20 aretoset 10mm. 100every are set every 10mm. S 3m S 3m GS3 SingleGS3 guide, mounted bottom Single on guide, mounted on bottom 100 to 200100 aretoset 50mm. 200every are set every 50mm. M 5m M 5m GS4 SingleGS4 guide, mounted on leftmounted on left Single guide, NM Reversed-home NM specification Reversed-home specification to 200mm 200 200mm X Length X Designation Length Designation *The brake *The specification can only becan usedonly withbeaused 70mm or higher brake specification with a 70mmstroke. or higher stroke. 3 � System Configuration Field Network DeviceNet CC-Link ProfiBus PLC 5 7 2 1 3 (Positioner type) (Program Type) PCON/ACON PCON/ACON PCON/ACON PCON/ACON RPCON/RACON PSEL C/CG type CY type PL/PO type SE type (ROBONET) ASEL 6 8 10 4 9 Actuator Controller connector between cables No. Title 1 2 for use with C/CG Type I/O Cable 3 4 5 6 7 8 9 10 Ty p e Actuator Controller connector between cables Program Type Teaching Pendant Program Type PC Software DC24V Power supply simple absolute unit Remar k s CB-PAC-PIO020 for use with CY Type CB-PACY-PIO020 for use with PL/PO type (pulse train) CB-PACPU-PIO020 A motor/encoder integrated cable for use with RCP2 (PCON/RPCON/PSEL) CB-PCS-MPA A motor/encoder integrated cable for use with RCA (ACON/RACON/ASEL) CB-ACS-MPA Standard Teaching Pendant CON-T Positioner Type Simple Teaching Pendant Teaching Pendant Positioner Type PC software Mo del RCM-E Data Setting Unit RCM-P RS232 Connection Type RCM-101-MW USB Connection Type RCM-101-USB See pag e (*) Cable length 2m (fitting for controller) for both PCON/ACON (*) (*) Cable lengths 1m/3m/5m (required option for actuator) P19 P19 P22 Cable length 5m for PCON/ACON/ROBONET P22 P22 Auxillary cable for PC connection (5m) for PCON/ACON/ROBONET Cable length 5m for both PSEL/ASEL 3 position enable switch for both PSEL/ASEL P22 P22 Standard specification SEL-T-J ANSI compatible specification SEL-TD-J RS232 Connection Type IA-101-X-MW-J USB Connection Type IA-101-X-USB 100-V input PS-241 (*) 200-V input PS-242 (*) for PCON PCON-ABU (*) for ACON ACON-ABU (*) Auxillary cable for PC connection (5m) for both PSEL/ASEL P22 P22 P22 P22 (*)Refer to ROBO Cylinder General Catalog 2008. 4 RCP2 ROBO Cylinder RCP2-SRA4R n Model Description RCP2 Series SRA4R     Type   I Encoder type I: Incremental specification ROBO Cylinder, Short Rod-Type, Actuator Diameter 45mm, Pulse Motor, Motor Reversing Specification 35P      P1               Lead Stroke       Compatible Controllers    Motor type Cable length 20:20mm P1: PCON to RPCON 200:200mm PSEL (10mm pitch setting) *Every 50mm for strokes over 100mm. 35P: Pulse motor 35oSize * See P3 for model descriptions. Option    Options below See Pricing Table N: None P: 1m S: 3m M: 5m Xoo: Length designation 5: 5mm 2.5: 2.5mm 40 Speed vs. Payload Graph n Lead 2.5 リード2.5 Load capacity (kg) Load capacity (kg) uses a pulse motor, the 35Since the RCP2 Series Horizontal payload decreases as speed increases. Use the 30table below to confirm that there is sufficient Lead 5 25payload at the desired speed. 40 20 リード2.5 Lead 2.5 35 15 30 10 Lead 5 25 5 20 0 50 150 Horizontal 100 150 200 Speed (mm/s) 250 300 50 100 150 200 Speed (mm/s) 20 18 Vertical 16 15 14 Lead 2.5 リード2.5 12 20 10 9 Lead リード55 18 Vertical 8 16 15 6 14 Lead 2.5 リード2.5 4 12 3 2 10 9 リード55 Lead 0 50 100 150 200 80 Speed (mm/s) 6 250 300 250 300 50 100Maximum 150 200 250 and Speed nStroke 300 10 5 NT OI Notes for selection Load capacity (kg) Load capacity (kg) P 0 0 (1) The RCP2 series uses a pulse motor so the load capacity decreases at high speeds. Confirm the payload at the desired speed in the Speed vs. Payload graph at right. (2) The payload is the value when operated at 0.3G acceleration (0.2G acceleration in vertical operation with lead 2.5). The above values are maximum acceleration. (3) The horizontal load capacity assumes use of an external guide.Take note that the interlock may get damaged if external force is applied from any direction other than the moving direction of the rod. 4 2 0 (Note 1) Note that the maximum load capacity decreases as the speed increases. 0 Actuator Specification Table nLeads and Payloads Lead Model RCP2-SRA4R-I-35P-5--P1-- ③ ② ① RCP2-SRA4R-I-35P-2.5--P1-- ③ ② ① Legend Stroke Cable Length Option (mm) Horizontal (kg) Vertical (kg) Maximum pushing force (N) (Note 2) 5 25 9 90 Maximum payload (Note 1) 2.5 35 15 RCP2-SRA4R 5 250 170 (Note 3) 2.5 125 (Unit = mm/s) Cable symbol P (1m) S (3m) M (5m) X06 (6m) – X10 (10m) X11 (11m) – X15 (15m) Special length X16 (16m) – X20 (20m) *A built-in motor-encoder cable is standard, and meets the robot cable specification. *See P19 for maintenance cables. Actuator Specification Optio n co de B FL FLR FT FT2/FT4 *The brake can be used at 70 stroke or above. 5 20 to 200 Standard type ③ Option Price List Foot brackets 2 (Mounted on right or left side) (every 10mm) Lead Type — — — — Foot bracket 1 (mounted on bottom) (mm) Speed (mm/s) 20 to 200 ② Cable Length Price List 20 to 5 0 6 0 to 1 00 150 200 Brake Flange bracket (front) Flange bracket (rear) Stroke (Note 2) Refer to the push force graph on P17. (Note 3) Every 50mm stroke at over 100mm. ③ ② ① Type code SRA4R Enco der type Incremental Title Stroke (every 10mm) ① Price List by Stroke ①Stroke (mm) 3 Se e p a ge − →P19 →P19 →P19 →P19 Item Drive System Positioning Repeatability Backlash Rod diameter Non-rotary Rod Precision Ambient operating temperature, humidity Service life De sc r i p ti on Ball screw φ8mm rolled C10 ±0.05mm 0.1mm or less φ22mm − 0 to 40°C, 85% RH or less (without condensation) 5000km RCP2 ROBO Cylinder Dimensions Drawing CAD drawings can be downloaded from the website. (*1) Connect the motor and encoder cable. See P19 for cable details. www.intelligentactuator.com 31.5 22 2-dimensional (*2) During home return, the slider moves to the mechanical end and then reverses. Pay attention to prevent contact between the slider and surrounding parts. 4.8 4.2 7.5 (2D width area) Cable joint connector (*1) Secure at least 100 㱢32 㱢22 㱢20 CAD 50 (210) 㪤10×1.25 4-M6, depth 12 22.5 34 34 4-M6, depth 12 45 34 14 95 E-M4, depth 10 (Opposite side is same) 14 34 45 ME 3 Home SE ME( 2) 3 40.5 17 C D×50 15 34 22 B A L st 6 17 M10×1.25 (19.6) E-M4, depth 10 Dimensions of provided nut 34 * The brake specification does not effect the external dimensions. However, 70 is the minimum stroke for the brake specification. (The brake is not compatible at 60 strokes and under.) 24 C D×50 ST: stroke SE: stroke end ME: mechanical end 8 nDimensions and Weight by Stroke Stroke (If the unit has a brake, add 0.2kg) L A B C D E 20 124.5 84 62 30 0 4 30 134.5 94 72 40 0 4 40 144.5 104 82 50 0 4 50 154.5 114 92 60 0 4 60 164.5 124 102 70 0 4 70 174.5 134 112 30 1 6 80 184.5 144 122 40 1 6 90 194.5 154 132 50 1 6 100 204.5 164 142 60 1 6 150 254.5 214 192 60 2 8 200 304.5 264 242 60 3 10 Weight (kg) 0.83 0.89 0.96 1.02 1.08 1.14 1.21 1.27 1.33 1.64 1.95 Compatible Controllers The RCP2 Series actuators can be operated with the following controllers. Select the type that is compatible with your application. Title Positioner Type External View Model PCON-C-35PI-NP-2-0 Features Maximum number of positioning points Up to 512-point positioning possible 512 points 3 points Safety category compatible Positioner type PCON-CG-35PI-NP-2-0 Solenoid valve type PCON-CY-35PI-NP-2-0 Same as solenoid valve Controlled operation enabled Pulse series input type (Differential line driver specification) PCON-PL-35PI-NP-2-0 Differential line driver compatible Pulse series input type Pulse series input type (Open collector specification) PCON-PO-35PI-NP-2-0 Open collector compatible Pulse series input type Serial communication type Field network type(*1) Program control type (−) PCON-SE-35PI-N-0-0 Serial communications Special Type 64 points RPCON-35P Field Network Dedicated type 768 points Programmed operation enabled Maximum biaxial operation enabled 1500 points PSEL-C-1-35PI-NP-2-0 Input power Power-supply capacity See page DC24V Maximum 2A →P20 (*1) In addition to the controller, the field network type also requires a Gateway unit (sold separately). 6 RCP2-SRA4R RCP2 ROBO Cylinder RCP2-SRGS4R n Model Description RCP2 Series SRGS4R   Type I     Encoder type I: Incremental specification 35P      ROBO Cylinder, Rod-Type with Short Single Guide, Actuator Diameter 45mm, Servo Motor, Motor Reversing Specification Motor type P1                 35P: Pulse motor 35oSize Lead 5: 5mm 2.5: 2.5mm Stroke   Compatible Controllers   20:20mm to 200:200mm (10mm pitch setting)   P1: PCON RPCON PSEL *Every 50mm for strokes over 100mm. * See P3 for model descriptions. Cable length Option    Options below See Pricing Table N: None P: 1m S: 3m M: 5m Xoo: Length designation nSpeed vs. Payload Graph Load capacity (kg)Load capacity (kg) 40 Since2.5 the RCP2 Series uses a pulse motor, the Lead リード2.5 35 payload decreases Horizontal as speed increases. Use the 30 table below to confirm that there is sufficient payload at the Lead 5 desired speed. 25 24 40 20 Lead 2.5 リード2.5 35 Horizontal 15 30 10 24 Lead 5 25 9 5 20 0 150 50 100 150 200 250 300 Speed (mm/s) 10 9 5 0 0 50 100 150 200 250 300 20 18 Vertical 16 15 14 Lead 2.5 リード2.5 12 20 10 18 Vertical (1) The RCP2 series uses a pulse motor so the load capacity decreases at high speeds. Confirm 168 15 リード5 Lead 5 the payload at the desired speed in the Speed vs. Payload graph at right. NT I 146 Lead 2.5 O リード2.5 (2) The payload is the value when operated at 0.3G acceleration (0.2G acceleration in vertical 124 3 Notes for operation with lead 2.5). 102 selection The above values are maximum acceleration. 1 08 (3) The horizontal load capacity assumes use of an external guide.See P.18 of the Technical 0 50 100リード5 150 200 250 Lead 5 Reference for the load capacities that can be used with the single guide that is provided. 6 Speed (mm/s) 4 3 2 1 Actuator Specification Table 0 0 50 100 150 200 250 (Note 1) Note that the maximum load capacity decreases as the speed increases. Leads and Payloads Stroke andSpeed Maximum Speed (mm/s) Stroke Maximum payload (Note 1) Maximum pushing Lead 20 to 200 Stroke force Model Load capacity (kg)Load capacity (kg) P Speed (mm/s) n n RCP2-SRGS4R-I-35P-5--P1-- ③ ② ① RCP2-SRGS4R-I-35P-2.5--P1-- ③ ② ① Legend Stroke Cable Length Option (mm) Horizontal (kg) Vertical (kg) (N) (Note 2) (mm) 5 24 8 90 20 to 200 2.5 ③ ② ① 35 15 ③ Option Price List Optio n co de S e e p a ge B Brake − FLR Flange bracket (rear) →P19 FT Foot bracket 1(mounted on bottom) →P19 FT2/FT4 Foot brackets 2 (Mounted on right and left sides) →P19 GS2 to GS4 Guide installation direction change →P8 *The brake can be used at 70 stroke or above. *Always input the direction the guide should be mounted on the model. *The guide and foot bracket cannot be used in the same direction. 7 RCP2-SRGS4R 5 250 170 (Note 3) 2.5 125 (Unit = mm/s) ② Cable Length Price List Type Cable symbol P (1m) S (3m) M (5m) X06 (6m) – X10 (10m) X11 (11m) – X15 (15m) Special length X16 (16m) – X20 (20m) *A built-in motor-encoder cable is standard, and meets the robot cable specification. *See P19 for maintenance cables. Standard type — — — — Title (every 10mm) Lead (Note 2) Refer to the push force graph on P17. (Note 3) Every 50mm stroke at over 100mm. Type code SRGS4 Enco der type Incremental 20 to 5 0 60 to 1 00 1 50 2 00 300 (every 10mm) ① Price List by Stroke ①Stroke (mm) 300 Actuator Specification Item Drive System Positioning Repeatability Backlash Rod diameter Non-rotary Rod Precision Ambient operating temperature, humidity Service life De sc r i p ti on Ball screw φ8mm rolled C10 ±0.05mm 0.1mm or less φ22mm ±0.05 degrees 0 to 40°C, 85% RH or less (without condensation) 5000km RCP2 ROBO Cylinder Dimensions Drawing CAD drawings can be downloaded from the website. (*1) Connect the motor and encoder cable. See P19 for cable details. www.intelligentactuator.com st 3 2-dimensional st+60 3 st 㱢10 3 (Amount the shaft moves from the ME position on the home side to the home position) Secure at least 100 90.5 45 50.5 2.5 45.5 20 䋨210䋩 5.5 80 45 㱢34 15 Cable joint connector (*1) 4 5 (Amount shaft pulls out at the SE position) 8 CAD (*2) During home return, the slider moves to the mechanical end and then reverses. Pay attention to prevent contact between the slider and surrounding parts. ME䋨 2䋩 42.5 Home SE ME E-M4, depth 10 (Opposite side is same) 4-M6, depth 12 34 34 20 30 (Visual A) 7.5 22.5 44 95 6-M5, depth 12 0.5 30 30 5 17 20 14.5 34.5 8 15 A 34 22 24 C GS2 Mounted on right D×50 8 * The brake specification does not effect the external dimensions. However, 70 is the minimum stroke for the brake specification. 34 Actuator D×50 B L E-M4, depth 10 GS4 Mounted on left C (The brake is not compatible at 60 strokes and under.) GS3 Mounted on bottom ST: stroke SE: stroke end ME: mechanical end Guide Mounting Direction (see Visual A) nDimensions and Weight by Stroke Stroke (If the unit has a brake, add 0.2kg) L A B C D E 20 126.5 84 62 30 0 4 30 136.5 94 72 40 0 4 40 146.5 104 82 50 0 4 50 156.5 114 92 60 0 4 60 166.5 124 102 70 0 4 70 176.5 134 112 30 1 6 80 186.5 144 122 40 1 6 90 196.5 154 132 50 1 6 100 206.5 164 142 60 1 6 150 256.5 214 192 60 2 8 200 306.5 264 242 60 3 10 Weight (kg) 1.2 1.27 1.34 1.41 1.48 1.54 1.61 1.68 1.75 2.09 2.43 Compatible Controllers The RCP2 Series actuators can be operated with the following controllers. Select the type that is compatible with your application. Title Positioner Type External View Model PCON-C-35PI-NP-2-0 Features Maximum number of positioning points Up to 512-point positioning possible 512 points 3 points Safety category compatible Positioner type PCON-CG-35PI-NP-2-0 Solenoid valve type PCON-CY-35PI-NP-2-0 Same as solenoid valve Controlled operation enabled Pulse series input type (Differential line driver specification) PCON-PL-35PI-NP-2-0 Differential line driver compatible Pulse series input type Pulse series input type (Open collector specification) PCON-PO-35PI-NP-2-0 Open collector compatible Pulse series input type Serial communication type Field network type(*1) Program control type (−) Serial communications Special Type 64 points RPCON-35P Field Network Dedicated type 768 points PSEL-C-1-35PI-NP-2-0 Programmed operation enabled Maximum biaxial operation enabled 1500 points PCON-SE-35PI-N-0-0 Input power Power-supply capacity See page DC24V Maximum 2A →P20 (*1) In addition to the controller, the field network type also requires a Gateway unit (sold separately). RCP2-SRGS4R 8 RCP2 ROBO Cylinder RCP2-SRGD4R n Model Description RCP2   SRGD4R Series    Type I   35P   Encoder type   I: Incremental specification ROBO Cylinder, Rod-Type with Short Guide, Actuator Diameter 45mm, Servo Motor, Motor Reversing Specification Motor type P1                 35P: Pulse motor 35oSize Lead   5: 5mm 2.5: 2.5mm Stroke    Compatible Controllers    Cable length P1: PCON RPCON PSEL 20:20mm to 200:200mm (10mm pitch setting) *Every 50mm for strokes over 100mm. * See P3 for model descriptions. Option    N: None P: 1m S: 3m M: 5m Xoo: Length designation Options below See Pricing Table nSpeed vs. Payload Graph 40 Since the RCP2 Series uses a pulse motor, the Lead 2.5 リード2.5 Load capacity (kg)Load capacity (kg) 35 payload decreasesHorizontal as speed increases. Use the 30 table below to confirm that there is sufficient payloadLead at the5 desired speed. 25 24 40 2.5 リード2.5 20 Lead 35 Horizontal 15 30 Lead 5 10 24 25 9 5 20 0 150 50 100 150 200 250 300 Speed (mm/s) 10 9 5 0 0 50 100 150 200 250 300 1 250 300 1 250 300 20 18 Vertical 16 15 14 Lead 2.5 リード2.5 12 20 10 18 Vertical 168 15 (1) The RCP2 series uses a pulse motor so the load capacity decreases at high speeds. Confirm the リード5 Lead 5 payload at the desired speed in the Speed vs. Payload graph at right. NT 146 Lead 2.5 リード2.5 OI (2) The payload is the value when operated at 0.3G acceleration (0.2G acceleration in vertical operation 124 3 with lead 2.5). Notes for 102 selection The above values are maximum acceleration. 0 8 (3) The horizontal load capacity assumes use of an external guide.See P.18 of the Technical Reference for 0 50 100Lead 200 リード5 5150 the load capacities that can be used with the double guide that is provided. 6 Speed (mm/s) 4 3 2 Actuator Specification Table 0 0 50 100 150 200 (Note 1) Note that the maximum load capacity decreases as the speed increases. Load capacity (kg)Load capacity (kg) P Speed (mm/s) nLeads and Payloads Lead Model RCP2-SRGD4R-I-35P-5--P1-- ③ ② ① RCP2-SRGD4R-I-35P-2.5--P1-- ③ ② ① Legend Stroke Cable Length Option (mm) Horizontal (kg) Vertical (kg) Maximum pushing force (N) (Note 2) 5 24 8 90 Maximum payload (Note 1) (mm) (every 10mm) Lead 20 to 200 5 250 2.5 35 15 170 (Note 3) 2.5 125 (Unit = mm/s) (Note 2) Refer to the push force graph on P17. (Note 3) Every 50mm stroke at over 100mm. ③ ② ① ② Cable Length Price List ①Stroke (mm) Type code SRGD4R Enco der type Incremental 20 to 5 0 60 to 1 00 1 50 2 00 — — — — Type Title Brake Foot bracket 1 (mounted on bottom) *The brake can be used at 70 stroke or above. *The foot bracket cannot be mounted on the side. Cable symbol P (1m) Standard type S (3m) M (5m) X06 (6m) – X10 (10m) X11 (11m) – X15 (15m) Special length X16 (16m) – X20 (20m) *A built-in motor-encoder cable is standard, and meets the robot cable specification. *See P19 for maintenance cables. ③ Option Price List Actuator Specification Optio n co de B FT Se e p a ge − →P19 Item Drive System Positioning Repeatability Backlash Rod diameter Non-rotary Rod Precision Ambient operating temperature, humidity Service life RCP2-SRGD4R 20 to 200 Stroke (every 10mm) ① Price List by Stroke 9 Speed nStroke and Maximum Speed (mm/s) Stroke De sc r i p ti on Ball screw φ8mm rolled C10 ±0.05mm 0.1mm or less φ22mm ±0.05 degrees 0 to 40°C, 85% RH or less (without condensation) 5000km RCP2 ROBO Cylinder Dimensions Drawing (*1) Connect the motor and encoder cable. See P19 for cable details. www.intelligentactuator.com (*2) During home return, the slider moves to the mechanical end and then reverses. Pay attention to prevent contact between the slider and surrounding parts. CAD SE st Home 3 ME䋨 2䋩 42.5 3 st+60 5 (Amount shaft pulls out at the SE position) 3 (Amount the shaft moves from the ME position on the home side to the home position) 7.5 15.5 45 45.5 50.5 15.5 7.5 䋨210䋩 45.5 Secure at least 100 45 5.5 45 Cable joint connector (*1) 4 st 㱢10 ME 2-dimensional 㱢34 CAD drawings can be downloaded from the website. E-M4, depth 10 (Opposite side is same) 4-M6, depth 12 30 105 126 136 30 34 34 20 30 22.5 0.5 30 7.5 44 34 95 4-M5 (for mounting to main unit) 8-M5, depth 12 (for mounting work piece) 17 20 14.5 34.5 8 C B L D×50 15 34 22 A E-M4, depth 10 34 * The brake specification does not effect the external dimensions. However, 70 is the minimum stroke for the brake specification. (The brake is not compatible at 60 strokes and under.) 24 C D×50 ST: stroke SE: stroke end ME: mechanical end 8 nDimensions and Weight by Stroke Stroke (If the unit has a brake, add 0.2kg) L A B C D E 20 126.5 84 62 30 0 4 30 136.5 94 72 40 0 4 40 146.5 104 82 50 0 4 50 156.5 114 92 60 0 4 60 166.5 124 102 70 0 4 70 176.5 134 112 30 1 6 80 186.5 144 122 40 1 6 90 196.5 154 132 50 1 6 100 206.5 164 142 60 1 6 150 256.5 214 192 60 2 8 200 306.5 264 242 60 3 10 Weight (kg) 1.47 1.55 1.62 1.7 1.77 1.84 1.92 1.99 2.07 2.44 2.81 Compatible Controllers The RCP2 Series actuators can be operated with the following controllers. Select the type that is compatible with your application. Title External View Model Features Maximum number of positioning points Up to 512-point positioning possible 512 points 3 points Positioner Type PCON-C-35PI-NP-2-0 Safety category compatible Positioner type PCON-CG-35PI-NP-2-0 Solenoid valve type PCON-CY-35PI-NP-2-0 Same as solenoid valve Controlled operation enabled Pulse series input type (Differential line driver specification) PCON-PL-35PI-NP-2-0 Differential line driver compatible Pulse series input type Pulse series input type (Open collector specification) PCON-PO-35PI-NP-2-0 Open collector compatible Pulse series input type Serial communication type Field network type(*1) Program control type (−) Serial communications Special Type 64 points RPCON-35P Field Network Dedicated type 768 points PSEL-C-1-35PI-NP-2-0 Programmed operation enabled Maximum biaxial operation enabled 1500 points PCON-SE-35PI-N-0-0 Input power Power-supply capacity See page DC24V Maximum 2A →P20 (*1) In addition to the controller, the field network type also requires a Gateway unit (sold separately). RCP2-SRGD4R 10 RCA ROBO Cylinder RCA-SRA4R n Model Description RCA Series SRA4R     Type   I ROBO Cylinder, Short Rod-Type, Actuator Diameter 45mm, Servo Motor, Motor Reversing Specification 20    Encoder type I: Incremental specification   A1               Motor type   20: Servo motor 20W Lead 5 : 5mm 2.5 : 2.5mm Stroke     Compatible Controllers 20:20mm to 200:200mm (10mm pitch setting)   A1: ACON RACON ASEL Cable length *Every 50mm for strokes over 100mm. * See P3 for model descriptions. Option    Options below See Pricing Table N: None P: 1m S: 3m M: 5m Xoo: Length designation P For low-power applications NT OI Notes for selection (1) The payload capacity acceleration is 0.3G acceleration (0.2G acceleration in vertical operation with lead 2.5). The above value is the maximum acceleration. (2) There is horizontal load capacity when external guides are used. Take note that if external force is applied in any direction other than moving direction the rod, the interlock may get damaged. Actuator Specification Table nLeads and Payloads nStroke and Maximum Speed Lead Model RCA-SRA4R-I-20-5--A1-- ③ ② ① RCA-SRA4R-I-20-2.5--A1-- ③ ② ① Legend Stroke Cable Length Option Maximum payload (Note 1) (mm) Horizontal (kg) Vertical (kg) Rated thrust (N) 5 9 3 41 (every 10mm) Lead 20 to 200 5 250 2.5 18 6.5 81 (Note 1) 2.5 125 (Unit = mm/s) (Note 1) Every 50mm for strokes over 100mm. ③ ② ① ② Cable Length Price List ①Stroke (mm) Type code SRA4 Enco der type Incremental 20 to 5 0 6 0 to 1 00 150 200 — — — — Type Title Brake Flange bracket (front) Flange bracket (rear) Foot bracket 1 (mounted on bottom) Foot brackets 2 (Mounted on right or left sides) for energy saving *The brake can be used at 70 stroke or above. Cable symbol P (1m) Standard type S (3m) M (5m) X06 (6m) – X10 (10m) X11 (11m) – X15 (15m) Special length X16 (16m) – X20 (20m) *A built-in motor-encoder cable is standard, and meets the robot cable specification. *See P19 for maintenance cables. ③ Option Price List RCA-SRA4R 20 to 200 Stroke (mm) (every 10mm) ① Price List by Stroke 11 Stroke Actuator Specification Optio n co de B FL FLR FT FT2/FT4 LA Se e p a ge − →P19 →P19 →P19 →P19 − Item Drive System Positioning Repeatability Backlash Rod diameter Non-rotary Rod Precision Ambient operating temperature, humidity Service life De sc r i p ti on Ball screw φ8mm rolled C10 ±0.05mm 0.1mm or less φ22mm − 0 to 40°C, 85% RH or less (without condensation) 5000km RCA ROBO Cylinder Dimensions Drawing CAD drawings can be downloaded from the website. (*1) Connect the motor and encoder cable. See P19 for cable details. www.intelligentactuator.com (*2) During home return, the slider moves to the mechanical end and then reverses. Pay attention to prevent contact between the slider and surrounding parts. 31.5 22 2-dimensional CAD 4.8 4.2 7.5 (2D width area) Secure at least 100 㱢32 㱢22 㱢20 Cable joint connector (*1) 50 (210) 㪤10×1.25 4-M6, depth 12 22.5 34 34 4-M6, depth 12 45 34 14 95 E-M4, depth 10 (Opposite side is same) 14 34 45 ME 3 Home SE ME( 2) 3 40.5 17 C D×50 15 34 22 B A L st 6 E-M4, depth 10 17 M10×1.25 (19.6) * The brake specification does not effect the external dimensions. However, 70 is the minimum stroke for the brake specification. Dimensions of provided nut 34 (The brake is not compatible at 60 strokes and under.) 24 C D×50 ST: stroke SE: stroke end ME: mechanical end 8 nDimensions and Weight by Stroke Stroke (If the unit has a brake, add 0.2kg) L A B C D E 20 124.5 84 62 30 0 4 30 134.5 94 72 40 0 4 40 144.5 104 82 50 0 4 50 154.5 114 92 60 0 4 60 164.5 124 102 70 0 4 70 174.5 134 112 30 1 6 80 184.5 144 122 40 1 6 90 194.5 154 132 50 1 6 100 204.5 164 142 60 1 6 150 254.5 214 192 60 2 8 200 304.5 264 242 60 3 10 Weight (kg) 0.78 0.84 0.9 0.96 1.03 1.09 1.15 1.21 1.27 1.59 1.9 Compatible Controllers RCA Series actuators can be operated with the following controllers.. Select the type that is compatible with your application. Title Positioner Type External View Model ACON-C-20I①-NP-2-0 Features Maximum number of positioning points Up to 512-point positioning possible 512 points 3 points Safety category compatible Positioner type ACON-CG-20I①-NP-2-0 Solenoid valve type ACON-CY-20I①-NP-2-0 Same as solenoid valve Controlled operation enabled Pulse series input type (Differential line driver specification) ACON-PL-20①-NP-2-0 Differential line driver compatible Pulse series input type Pulse series input type (Open collector specification) ACON-PO-20I①-NP-2-0 Open collector compatible Pulse series input type Serial communication type Field network type (*1) Program control type (−) Serial communications Special Type 64 points RACON-20① Field Network Dedicated type 768 points ASEL-C-1-20I①-NP-2-0 Programmed operation enabled Maximum biaxial operation enabled 1500 points ACON-SE-20I①-N-0-0 (*1) In addition to the controller, the field network type also requires a Gateway unit (sold separately). Input power Power-supply capacity See page (Standard) Rated 1.3A Peak 4.4A DC24V (energy-saving) Rated 1.3A Peak 2.5A →P20 (*2) *ASEL is for uniaxial specification. (*2) is entered as the code (LA) when designating for low-power applications.  12 RCA-SRA4R RCA ROBO Cylinder RCA-SRGS4R n Model Description RCA Series I SRGS4R     Type   20    Encoder type I: Incremental specification ROBO Cylinder, Rod-Type with Short Single Guide, Actuator Diameter 45mm, Servo Motor, Motor Reversing Specification Motor type   A1                 20: Servo motor 20W Lead 5 : 5mm 2.5 : 2.5mm Stroke     Compatible Controllers 20:20mm to 200:200mm (10mm pitch setting) A1: ACON RACON ASEL    *Every 50mm for strokes over 100mm. * See P3 for model descriptions. Cable length    N: None P: 1m S: 3m M: 5m Xoo : Length designation Option Options below See Pricing Table P For low-power applications NT OI Notes for selection (1) The payload capacity acceleration is 0.3G acceleration (0.2G acceleration in vertical operation with lead 2.5). The above value is the maximum acceleration. (2) There is horizontal load capacity when external guides are used. See P.18 of the Technical Reference for the load capacities that can be used with the single guide that is provided. Actuator Specification Table nLeads and Payloads nStroke and Maximum Speed Lead Model (mm) Horizontal (kg) Vertical (kg) Rated thrust (N) 5 9 2 41 RCA-SRGS4R-I-20-5--A1-- ③ ② ① RCA-SRGS4R-I-20-2.5--A1-- ③ ② ① Legend Stroke Cable Length Option Maximum payload (Note 1) 2.5 18 5.5 81 (Note 1) 5 250 2.5 125 (Unit = mm/s) Type Title Brake Flange bracket (rear) Foot bracket 1 (mounted on bottom) Foot brackets 2 (Mounted on right and left sides) Cable symbol P (1m) S (3m) M (5m) X06 (6m) – X10 (10m) X11 (11m) – X15 (15m) Special length X16 (16m) – X20 (20m) *A built-in motor-encoder cable is standard, and meets the robot cable specification. *See P19 for maintenance cables. Standard type — — — — Actuator Specification Optio n co de B FLR FT FT2/FT4 GS2 to GS4 LA Guide mounting direction For low-power applications *The brake can be used at 70 stroke or above. *Always input the direction the guide should be mounted on the model. *The guide and foot bracket cannot be used in the same direction. RCA-SRGS4R 20 to 200 ② Cable Length Price List ③ Option Price List 13 (every 10mm) Lead (Note 1) Every 50mm for strokes over 100mm. ③ ② ① Type code SRGS4R Enco der type Incremental 2 0 to 5 0 6 0 to 1 00 150 200 20 to 200 Stroke (mm) (every 10mm) ① Price List by Stroke ①Stroke (mm) Stroke Se e p a ge − →P19 →P19 →P19 →P14 − Item Drive System Positioning Repeatability Backlash Rod diameter Non-rotary Rod Precision Ambient operating temperature, humidity Service life De sc r i p ti on Ball screw φ8mm rolled C10 ±0.05mm 0.1mm or less φ22mm ±0.05 degrees 0 to 40°C, 85% RH or less (without condensation) 5000km RCA ROBO Cylinder Dimensions Drawing CAD drawings can be downloaded from the website. (*1) Connect the motor and encoder cable. See P19 for cable details. www.intelligentactuator.com ME䋨 2䋩 42.5 Home SE ME 2-dimensional st 3 st+60 3 㱢10 3 (Amount the shaft moves from the ME position on the home side to the home position) Secure at least 100 90.5 45 50.5 2.5 45.5 20 䋨210䋩 5.5 80 45 㱢34 15 Cable joint connector (*1) 4 st 5 (Amount shaft pulls out at the SE position) 8 CAD (*2) During home return, the slider moves to the mechanical end and then reverses. Pay attention to prevent contact between the slider and surrounding parts. E-M4, depth 10 (Opposite side is same) 4-M6, depth 12 34 34 20 30 (Visual A) 7.5 22.5 44 95 6-M5, depth 12 0.5 30 30 5 17 20 14.5 34.5 8 15 A 34 22 24 C GS2 Mounted on right D×50 8 * The brake specification does not effect the external dimensions. However, 70 is the minimum stroke for the brake specification. (The brake is not compatible at 60 strokes and under.) 34 Actuator D×50 B L E-M4, depth 10 GS4 Mounted on left C GS3 Mounted on bottom ST: stroke SE: stroke end ME: mechanical end Guide Mounting Direction (see Visual A) nDimensions and Weight by Stroke Stroke (If the unit has a brake, add 0.2kg) L A B C D E 20 126.5 84 62 30 0 4 30 136.5 94 72 40 0 4 40 146.5 104 82 50 0 4 50 156.5 114 92 60 0 4 60 166.5 124 102 70 0 4 70 176.5 134 112 30 1 6 80 186.5 144 122 40 1 6 90 196.5 154 132 50 1 6 100 206.5 164 142 60 1 6 150 256.5 214 192 60 2 8 200 306.5 264 242 60 3 10 Weight (kg) 1.15 1.21 1.28 1.35 1.42 1.49 1.56 1.62 1.69 2.03 2.38 Compatible Controllers RCA Series actuators can be operated with the following controllers.. Select the type that is compatible with your application. Title Positioner Type External View Model ACON-C-20I①-NP-2-0 Features Maximum number of positioning points Up to 512-point positioning possible 512 points 3 points Safety category compatible Positioner type ACON-CG-20I①-NP-2-0 Solenoid valve type ACON-CY-20I①-NP-2-0 Same as solenoid valve Controlled operation enabled Pulse series input type (Differential line driver specification) ACON-PL-20I①-NP-2-0 Differential line driver compatible Pulse series input type Pulse series input type (Open collector specification) ACON-PO-20I①-NP-2-0 Open collector compatible Pulse series input type Serial communication type Field network type (*1) Program control type (−) Serial communications Special Type 64 points RACON-20① Field Network Dedicated type 768 points ASEL-C-1-20I①-NP-2-0 Programmed operation enabled Maximum biaxial operation enabled 1500 points ACON-SE-20I①-N-0-0 (*1) In addition to the controller, the field network type also requires a Gateway unit (sold separately). Input power Power-supply capacity See page (Standard) Rated 1.3A Peak 4.4A DC24V (energy-saving) Rated 1.3A Peak 2.5A →P20 (*2) *ASEL is for uniaxial specification. (*2) is entered as the code (LA) when designating for low-power applications.  14 RCA-SRGS4R RCA ROBO Cylinder RCA-SRGD4R n Model Description RCA Series I SRGD4R     Type   Encoder type I: Incremental specification 20      ROBO Cylinder, Rod-Type with Short Double Guide, Actuator Diameter 45mm, Servo Motor, Motor Reversing Specification A1               Motor type   20: Servo motor 20W Lead 5 : 5mm 2.5 : 2.5mm   Stroke Compatible Controllers   20:20mm to 200:200mm (10mm pitch setting) A1: ACON RACON ASEL    *Every 50mm for strokes over 100mm. * See P3 for model descriptions. Cable length    N: None P: 1m S: 3m M: 5m Xoo : Length designation Option Options below See Pricing Table P For low-power applications NT OI Notes for selection (1) The payload capacity acceleration is 0.3G acceleration (0.2G acceleration in vertical operation with lead 2.5). The above value is the maximum acceleration. (2) There is horizontal load capacity when external guides are used. See P.18 of the Technical Reference for the load capacities that can be used with the double guide that is provided. Actuator Specification Table nLeads and Payloads nStroke and Maximum Speed Lead Model RCA-SRGD4R-I-20-5--A1-- ③ ② ① RCA-SRGD4R-I-20-2.5--A1-- ③ ② ① Legend Stroke Cable Length Option Maximum payload (Note 1) (mm) Horizontal (kg) Vertical (kg) Rated thrust (N) 5 9 2 41 Stroke 2.5 18 20 to 200 5 250 5.5 81 (Note 1) 2.5 125 (Unit = mm/s) (Note 1) Every 50mm for strokes over 100mm. ③ ② ① ② Cable Length Price List ①Stroke (mm) Type code SRGD4 Enco der type Incremental 20 to 5 0 60 to 1 00 150 200 — — — — Type Title Brake Foot bracket1(mounted on bottom) *The brake can be used at 70 stroke or above. *The foot bracket cannot be mounted on the side. Cable symbol P (1m) Standard type S (3m) M (5m) X06 (6m) – X10 (10m) X11 (11m) – X15 (15m) Special length X16 (16m) – X20 (20m) *A built-in motor-encoder cable is standard, and meets the robot cable specification. *See P19 for maintenance cables. ③ Option Price List Actuator Specification Optio n co de B FT Se e p a ge − →P19 Item Drive System Positioning Repeatability Backlash Rod diameter Non-rotary Rod Precision Ambient operating temperature, humidity Service life RCA-SRGD4R (every 10mm) Lead (every 10mm) ① Price List by Stroke 15 20 to 200 Stroke (mm) De sc r i p ti on Ball screw φ8mm rolled C10 ±0.05mm 0.1mm or less φ22mm ±0.05 degrees 0 to 40°C, 85% RH or less (without condensation) 5000km RCA ROBO Cylinder Dimensions Drawing (*1) Connect the motor and encoder cable. See P19 for cable details. www.intelligentactuator.com 2-dimensional SE st Home 3 3 (*2) During home return, the slider moves to the mechanical end and then reverses. Pay attention to prevent contact between the slider and surrounding parts. st+60 5 (Amount shaft pulls out at the SE position) 7.5 15.5 CAD ME䋨 2䋩 42.5 3 (Amount the shaft moves from the ME position on the home side to the home position) 45 45.5 50.5 15.5 7.5 䋨210䋩 45.5 Secure at least 100 45 5.5 45 Cable joint connector (*1) 4 st 㱢10 ME 㱢34 CAD drawings can be downloaded from the website. E-M4, depth 10 (Opposite side is same) 4-M6, depth 12 0.5 30 105 126 136 30 34 34 20 30 30 7.5 22.5 44 34 95 4-M5 (for mounting to main unit) 8-M5, depth 12 (for mounting work piece) 20 14.5 34.5 8 C 17 B L D×50 15 A 34 22 E-M4, depth 10 34 * The brake specification does not effect the external dimensions. However, 70 is the minimum stroke for the brake specification. (The brake is not compatible at 60 strokes and under.) 24 C D×50 ST: stroke SE: stroke end ME: mechanical end 8 nDimensions and Weight by Stroke Stroke (If the unit has a brake, add 0.2kg) L A B C D E 20 126.5 84 62 30 0 4 30 136.5 94 72 40 0 4 40 146.5 104 82 50 0 4 50 156.5 114 92 60 0 4 60 166.5 124 102 70 0 4 70 176.5 134 112 30 1 6 80 186.5 144 122 40 1 6 90 196.5 154 132 50 1 6 100 206.5 164 142 60 1 6 150 256.5 214 192 60 2 8 200 306.5 264 242 60 3 10 Weight (kg) 1.42 1.49 1.56 1.64 1.71 1.79 1.86 1.94 2.01 2.38 2.75 Compatible Controllers RCA Series actuators can be operated with the following controllers. Select the type that is compatible with your application. Title Positioner Type External View Model ACON-C-20I①-NP-2-0 Features Maximum number of positioning points Up to 512-point positioning possible 512 points 3 points Safety category compatible Positioner type ACON-CG-20I①-NP-2-0 Solenoid valve type ACON-CY-20I①-NP-2-0 Same as solenoid valve Controlled operation enabled ACON-PL-20I①-NP-2-0 Differential line driver compatible Pulse series input type ACON-PO-20I①-NP-2-0 Open collector compatible Pulse series input type Pulse series input type (Differential line driver specification) Pulse series input type (Open collector specification) Serial communication type Field network type (*1) Program control type (−) Serial communications Special Type 64 points RACON-20① Field Network Dedicated type 768 points ASEL-C-1-20I①-NP-2-0 Programmed operation enabled Maximum biaxial operation enabled 1500 points ACON-SE-20I①-N-0-0 Input power Power-supply capacity See page (Standard) Rated 1.3A Peak 4.4A DC24V (energy-saving) Rated 1.3A Peak 2.5A →P20 (*2) (*1) In addition to the controller, the field network type also requires a Gateway unit (sold separately). *ASEL is for uniaxial specification. (*2) is entered as the code (LA) when designating for low-power applications.  RCA-SRGD4R 16 Technical Reference Diagram Showing Relationship Between Push Force & Current-Limiting The push force applied in push-motion operation can be changed freely by changing the current-limiting value in the controller. Use the graph below to check the required push force. Caution for Use • The relationships of push force the and current-limiting value represent reference values and may differ slightly from actual values. • If the current-limiting value is less than 20%, the push force may fluctuate. Keep the current-limiting value to 20% or above. • The travel speed is fixed to 20 mm/s during push-motion operation. • For applications requiring the use of push operation, please use the RCP2. (Pulse Motor) RCP2-SRA4R/SRGS4R/SRGD4R Drawing Showing Correlation Between Push Force & Current Limitations 200 Push Force (N) 150 䊥䊷䊄2.5 Lead 2.5 100 Lead 5 50 0 0 10 20 30 40 50 Current Limitations (Percentage %) Allowable Rotating Torque If rotating torque is to be applied, keep the torque within the range specified below. Take note that standard and single-guide types cannot receive rotating torque. Allowable Rotating Moment (N·m) Allowable Rotating Moment 2.5 2.0 1.5 1.0 0.5 0.0 17 0 20 40 60 80 100 120 Stroke (mm) 140 160 180 200 60 70 Technical Reference Relationship Between Allowable Load at Tip & Traveling Life The greater the load at the guide tip, the shorter the traveling life becomes. Select an appropriate model by considering an optimal F↓ F balance between load and life. Double guide type (vertical and horizontal) F Single guide type Relationship Between Load on the Tip and Service Life by Stroke Single Guide Relationship Between Load on the Tip and Service Life, by Stroke Double Guide 50 40 45 35 40 20 50 100 150 200 25 20 15 Radial Load (N) Radial Load (N) 30 10 35 20 50 100 150 200 30 25 20 15 10 5 5 0 10 100 1000 Service Life (km) 0 10000 10 100 1000 Service Life (km) 10000 Radial Load & Deflection at Tip The diagrams below show how the load applied at the tip of the guide correlates with the deflection that results. Single guide type Radial Load & Deflection on the Tip, Single Guide 2.0 1.8 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 0 5 10 15 20 25 30 Load (N) 35 40 45 50 Double guide type (vertical) 1.2 Deflection (mm) 1.0 0.8 0.6 0.4 0.2 0 5 10 15 20 25 30 Load (N) F↓ F F Double guide type (horizontal) Radial Load & Deflection on the Tip, Double Guide (Vertical) 0.0 35 40 40 50 Home 20st 30st 40st 50st 60st 70st 80st 90st 10st 11st 12st 13st 14st 15st 16st 17st 18st 19st 200st Radial Load & Deflection on the Tip, Double Guide (Horizontal) 1.2 1.0 Deflection (mm) Deflection (mm) 1.6 Home 20st 30st 40st 50st 60st 70st 80st 90st 100st 110st 120st 130st 140st 150st 160st 170st 180st 190st 200st 0.8 0.6 0.4 0.2 0.0 0 5 10 15 20 25 Load (N) 30 35 40 45 50 Home 20st 30st 40st 50st 60st 70st 80st 90st 100st 110st 120st 130st 140st 150st 160st 170st 180st 190st 200st 18 RCP2/RCA-Compatible Controllers Actuator options (flange/foot brackets) Model Options [FL] Single Model, RCP2-FL-SRA4 Model Options [FLR] Single Model, RCP2-FL-SRA4 4-φ6.6, through When flange bracket (front) is mounted Model Options [FT] Single Model, RCP2-FT-SRA4 When flange bracket (rear) is mounted Model Options [FT2 (mounted on right side/FT4 (mounted on left side)] Single Model, RCP2-FTS-SRA4 4-φ6.6, through 71 57 20 60 75 10 10 (40.5) 5.25 0.25 60 75 5.25 0.25 34 44.5 34 44.5 4-φ6.6, through st+10 4-φ6.6, through 10 95 105 121 107 20 10 When foot bracket (bottom) is mounted 45 55 st+10 When foot bracket (side) is mounted Maintenance parts (motor-encoder cable) Motor-encoder cable for RCP2 Model *Enter the cable length (L) for □□□, up to a maximum compatible length of 20m. Example: 080=8m CB-PCS-MPA□□□ Signal Pin No. B1 A A2 VMM A1 /A B3 B B2 VMM A3 /B L (φ12) (20) (18) (30) (5) (18) (15) (8) (23) (Front view)(8) (Front view) Actuator Side Controller side BK+ BK− LS+ LS− A+ A− B+ B− NC VPS VCC GND NC FG 14 13 16 15 12 11 10 9 8 7 6 5 4 1 (Wire color) Black White Red Green Yellow Brown Pink (Red�) Pink (Blue�) White (Red�) White (Blue�) Orange (Red�) Orange (Blue�) Gray (Red�) Gray (Blue�) Orange (Blue� consecutive) Gray (Red� consecutive) Gray (Blue� consecutive) Shield Signal A1 B1 A2 B2 A3 B3 A4 B4 A5 B5 A6 B6 A7 B7 A8 B8 A9 B9 A10 B10 A11 B11 Pin No. A VMM /A B VMM /B NC NC BK+ BK− LS+ LS− A+ A− B+ B− NC VPS VCC GND NC FG Motor-encoder cable for RCA *Enter the cable length (L) for □□□, up to a maximum compatible length of 20m. Example: 080=8m CB-ACS-MPA□□□ Model Signal U V W Pin No. 1 2 3 (Wire color) Red Yellow Black BK+ BK− LS+ LS− A+ A− B+ B− Z+ Z− − /PS VCC GND NC FG 16 15 18 17 14 13 12 11 10 9 8 7 6 5 Yellow (Red�) Yellow (Blue�) Pink (Red�) Pink (Blue�) White (Red�) White (Blue�) Orange (Red�) Orange (Blue�) Gray (Red�) Gray (Blue�) Orange (Red� consecutive) Orange (Blue� consecutive) Gray (Red� consecutive) Gray (Blue� consecutive) 1 Shield L (10) (φ12) (8) (30) (12) (18) (5) (18) (23) (Front view) (8) Controller side 19 (Front view) Actuator Side Pin No. A1 B1 A2 B2 A3 B3 A4 B4 A5 B5 A6 B6 A7 B7 A8 B8 A9 B9 A10 B10 A11 B11 Signal U V W NC NC NC BK+ BK− LS+ LS− A+ A− B+ B− Z+ Z− − /PS VCC GND NC FG RCP2/RCA-Compatible Controllers Controllers for RCP2/RCA Model List PCON/ACON C CG CY PL/PO SE RPCON RACON (ROBONET) Positioner type Safety category compatible type Solenoid valve type Pulse in-line control type Serial Communication Type Field Network type Program Type Serial Communication Dedicated Controller (*1) Can be operated through DeviceNet CC-Link ProfiBus Programmable, Built-in Sequence Function . Model Name PSEL/ASEL Appearance Features Positioner can be positioned for up to 512 points. Can be operated Safety category using the same control compatible specification as an air cylinder. An in-line pulse can be used to control as desired (*1) A Gateway unit (sold separately) is required to use RPCON/RACON. Model PCON/ACON Controller PCON/ACON 0 Type C Positioner type Category CG Safety Compatible Type 20I PL PO I/O Type I/O Cable Length For RCP2-SRA4R/ NP (standard) NPN specification 0 No cable (*) For RCA-SRA4R/ SRGS4R/SRGD4R PN PNP specification 2 2m 3 3m 5 5m 35PI SRGS4R/SRGD4R CY Solenoid valve type Pulse in-line control type (differential receiver type) Pulse in-line control type (open collector type) Motor/Encoder Type The network specification (DV/CC/PR) is only compatible with the positioner type (C) and safety category compatible type (CG). SE Serial Communication Type N No I/O (SE type) DeviceNet connection DV specification connection CC CC-Link specification ProfiBus connection PR specification Power supply Simple absolute unit use with simple ABU For absolute unit Not for use with simple absolute unit 0 DC24V (*) The PCON/ACON-SE and PCON/ACON-C(CG)-DV/CC/PR types have no I/O. ROBONET Controller RPCON/RACON Motor type Simple absolute unit For RCP2-SRA4R/ ABU For use with simple 35P SRGS4R/SRGD4R 20 absolute unit Not for use with simple absolute unit For RCA-SRA4R/ SRGS4R/SRGD4R * A Gateway unit is required to connect a network when using the RPCON/RACON types. See the ROBONET catalog for details. PSEL/ASEL Controller PSEL/ASEL C 0 Number of axes for connection 1 2 35PI 35PIB *Information under “2-axis” is not required for a 1-axis specification. I/O Type I/O Cable Length NP NPN specification -a is specification 2-a is specification Motor/Encoder Type Motor/Encoder Type (first axis) (2-axis) 20I 20IB For RCP2-SRA4R/ SRGS4R/SRGD4R Use with the brake specifications in the above model For C -S 4 / S S4 /S D4 se with the brake specifications in the above model 35PI 35PIB 20I 20IB For RCP2-SRA4R/ SRGS4R/SRGD4R Use with the brake specifications in the above model For RCA-SRA4R/ SRGS4R/SRGD4R Use with the brake specifications in the above model 0 (standard) Power supply DC24V PN PNP specification DeviceNet connection DV specification 0 No cable (*) CC specification 2 2m PR specification 3 3m 5 5m CC-Link connection ProfiBus connection (*) The network specification (DV/CC/PR) types have no I/O. 20 RCP2/RCA-Compatible Controllers Specification Table Item Specification PCON/ACON Controller type C CG CY Maximum number of control axes PO RPCON/RACON (ROBONET) SE Positioner type 512 points 40-pin connector Number of I/O 16 input, 16 output Serial communications Peripheral Device Cables for communicating Solenoid valve type 3 points 12-pin connector 4 input 6 output PSEL/ASEL Pulse series input type − 14-pin connector Serial Communication Type 64 points − Up to 16-axis can be connected and operated. Field Network 768 points − 4 input, 4 output − − 34-pin connector 24 input 8 output RS232 CB-RCB-CTL002 − CB-DS-PIO 1-axis Operation method Number of positions I/O connector RS485 CB-PACY-PIO CB-PAC-PIO Command pulse input method Maximum input pulse frequency Position detection method Motor/Encoder cable Input power RCP2 (all models) Power-supply capacity RCA PL − − SRA4R SRGS4R SRGD4R CB-PACPU-PIO Differential line driver Open collector − 200kpps 60kpps − Incremental encoder CB-PCS-MPA��� (for PCON)/CB-ACS-MPA���(for ACON)(Max. length 20m) DC24V±10% Maximum 2A Max. 2A (*1) Rated 1.3A, max. 4.4A (standard specification) Rated 1.3A, max. 2.5A (low-power specification) Dielectric strength voltage Program 1500 points Max. 5.5A (*2) (*3) DC500V 10MΩ DC500V 1MΩ Ambient operating temperature, Ambient operating humidity. 2-axes 0 to 40°C 10 to 95% (free from condensation or corrosive gases) Ingress Protection Mass IP20 Approx. 130g Approx. 300g Approx. 450g Approx. 200g (*1) During use, the following amount of power is required: 2A x the number of units used, plus the power consumed by the Gateway unit (approx. 0.6A). (*2) The following power capacity is required for RACON: ACON power capacity x number of units used, plus the power consumed by the Gateway unit (approx. 0.6A). (*3) The following power capacity is required for ASEL: ACON power capacity x number of control axes, plus the power for the control unit (1.2A). Dimensional Outline Drawing 68.1 35 120 178.5 㱢5 170.5 35 PCON-CY/PL/PO/SE ACON-CY/PL/PO/SE 84 5 RPCON RACON PSEL ASEL 䋨160䋩 43 137 151 159 (50 from the center of the DIN rail) 35.4 100 110 䋨10䋩 5 (80) 㱢 *Can be mounted on the DIN rail (35mm) 34 (69.3 from the DIN rail surface) 73.3 21 68.1 5 5 䋨0.5䋩 㱢5 112 PCON-C/CG ACON-C/CG 5 3 RCP2/RCA-Compatible Controllers Controller Options This is a teaching device that provides information on functions such as position input, running tests, and monitoring. Teaching Pendant Item RCM-E RCM-P CON-T SEL-T-J SEL-TD-J Exterior dimensions Compatible controllers Position input Program input Actuator operation Display 3 position enabling switch Compatible with the ANSI standard Compatible with the CE mark Compatible with the UL standard PCON/ACON/RPCON/RACON � × × 16 characters x 2 lines, LCD display × × × × × × × × � × × × � × 5m 0 to 40°C temperature, 85% RH or less Cable length Ambient operating temperature, humidity Ingress Protection Mass PSEL/ASEL � � � 20 characters x 4 lines, LCD display × × � × � × � − Approx. 400g − Approx. 360g PC-compatible software (Windows only) IP54 Approx. 400g Approx. 400g Feature � � � � � � � Approx. 400g A startup support software program offering program/position input function, test operation function, monitoring function, and more. The functions needed for debugging have been enhanced to help reduce the startup time. PC-compatible software for PCON/ACON/RPCON/RACON (for RS232 connection) � Model RCM−101−MW � Configuration (comes with external device communication cable + RS232 conversion unit) RS232 conversion adapter RCB-CV-MW 5m External device communication cable CB-RCA-SIO050 0.3m PC software (CD) PC-compatible software for PCON/ACON/RPCON/RACON (for USB connection) � Model RCM−101−USB (comes with external device communication cable + USB conversion adapter + USB cable) USB conversion adapter RCB-CV-USB � Configuration PC software (CD) 1m 5m USB cable CB-SEL-USB010 External device communication cable CB-RCA-SIO050 PC-compatible software for PSEL/ASEL (for RS232 connection) � Model IA−101−X−MW−J (comes with RS232C cable + connector conversion cable) � Configuration 5m PC software (CD) RS232C cable: CB-ST-E1MW050-EB 0.2m Connector conversion cable: CB-SEL-SJ002 PC-compatible software (for USB connection) � Model IA−101−X−USB (for USB cable) � Configuration Dummy plug DP-3 1m PC software (CD) USB cable CB-SEL-USB010 22 Catalog Number CJ0131-1A (October, 2008) Catalog Number CJ0131-1A (October, 2008) Website: www.intelligentactuator.com Website: www.intelligentactuator.com Due to product improvements, the information presented in this catalog is subject to change without notice Due to product improvements, the information presented in this catalog is subject to change without notice