Preview only show first 10 pages with watermark. For full document please download

Rd Coaxial Switches (ard) Features Typical Applications

   EMBED


Share

Transcript

26.5 GHz max. Coaxial switches coming in SPDT, Transfer, and SP6T types 6GHz type FEATURES TYPICAL APPLICATIONS 1. Excellent high frequency characteristics (50Ω, to 26.5Ghz) 2. SPDT, Transfer and SP6T types are available. 3. High sensitivity Nominal operating power: 840 mW (SPDT/SP6T, Fail-safe type, with indicator) 1,540 mW (Transfer, Fail-safe type, with indicator) Wireless and mobile communication • Cellular phone base station • Amplifier switching Digital broadcasting • Broadcasting relay station • Broadcasting equipment High frequency measuring market All types of inspection equipment *Without 24V type 4. Long-lasting life: min. 5 × 106 5. With termination type is added. (SP6T) Thanks to the addition of termination, steady high frequency characteristics can be maintained when contacts are either open or closed and this contributes to increase system reliability. RoHS compliant RD COAXIAL SWITCHES (ARD) If you consider using applications with low level loads or with high frequency switching, please consult us. HIGH FREQUENCY CHARACTERISTICS (Impedance 50Ω) Frequency V.S.W.R. (max.) V.S.W.R. (SP6T With termination) (max.) Insertion loss (dB. max.) Isolation (dB. min.) to 1 GHz 1.1 1 to 4 GHz 1.15 1.20 0.2 85 80 4 to 8 GHz*1 1.25 1.40 0.3 70 8 to 12.4 GHz 1.35 1.50 0.4 65 12.4 to 18 GHz 1.5 — 0.5 60 18 to 26.5 GHz*2 1.7 — 0.8 55 Notes: *1 The 6GHz type only has the above characteristics up to 6GHz. *2 18 to 26.5GHz characteristics can be applied 26.5GHz type only (SPDT, Transfer) ORDERING INFORMATION ARD RD coaxial switches Frequency 1: to 18GHz (SPDT) 2: to 18GHz (Transfer) 3: to 13GHz (SP6T) 5: to 26.5GHz (SPDT) 6: to 26.5GHz (Transfer) 7: to 6GHz (SPDT) Operating function 00: Fail-safe (with indicator) 20: Latching (with indicator) 51: Latching with TTL driver (SPDT, Transfer) (with self cut-off function) (with indicator) 02: Fail-safe (without indicator) 22: Latching (without indicator) 53: Latching with TTL driver (SPDT) (with self cut-off function) (without indicator) Nominal operating voltage, V DC 4H: 4.5 (Fail-safe, Latching type only) 05: 5 (Latching with TTL driver type only) 12: 12 24: 24 Operation terminal Nil: Solder terminal C: Connector cable (SPDT type only) Termination (SP6T type only) Nil: No termination Z: With termination HF data attached Nil: No HF test data attached Q: HF test data attached Note: Sealed types also available, please consult us (SPDT only) –1– ASCTB103E 201411-T RD (ARD) TYPES 1. SPDT 1) Solder terminal Operating function Fail-safe (with indicator) Latching (with indicator) Latching with TTL driver (with self cut-off function) (with indicator) Fail-safe (without indicator) Latching (without indicator) Latching with TTL driver (with self cut-off function) (without indicator) Nominal operating voltage 6GHz type No HF datasheet attached 18GHz type No HF datasheet HF datasheet attached attached 26.5GHz type No HF datasheet HF datasheet attached attached 4.5 V DC 12 V DC 24 V DC ARD7004H ARD70012 ARD70024 ARD1004H ARD10012 ARD10024 ARD1004HQ ARD10012Q ARD10024Q ARD5004H ARD50012 ARD50024 ARD5004HQ ARD50012Q ARD50024Q 4.5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC ARD7204H ARD72012 ARD72024 ARD75105 ARD75112 ARD75124 ARD1204H ARD12012 ARD12024 ARD15105 ARD15112 ARD15124 ARD1204HQ ARD12012Q ARD12024Q ARD15105Q ARD15112Q ARD15124Q ARD5204H ARD52012 ARD52024 ARD55105 ARD55112 ARD55124 ARD5204HQ ARD52012Q ARD52024Q ARD55105Q ARD55112Q ARD55124Q 4.5 V DC 12 V DC 24 V DC ARD7024H ARD70212 ARD70224 — — — — 4.5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC ARD7224H ARD72212 ARD72224 ARD75305 ARD75312 ARD75324 — — — — — — — — Note: Standard packing; Carton: 1 pc. Case: 20 pcs. 2) Connector cable Operating function Fail-safe Latching Latching with TTL driver (with self cut-off function) Nominal operating voltage 4.5 V DC 12 V DC 24 V DC 4.5 V DC 12 V DC 24 V DC 5 12 24 V DC V DC V DC 18GHz type No HF datasheet attached HF datasheet attached ARD1004HC ARD1004HCQ ARD10012C ARD10012CQ ARD10024C ARD10024CQ ARD1204HC ARD1204HCQ ARD12012C ARD12012CQ ARD12024C ARD12024CQ ARD15105C ARD15112C ARD15124C 26.5GHz type No HF datasheet attached HF datasheet attached ARD5004HC ARD5004HCQ ARD50012C ARD50012CQ ARD50024C ARD50024CQ ARD5204HC ARD5204HCQ ARD52012C ARD52012CQ ARD52024C ARD52024CQ ARD15105CQ ARD15112CQ ARD15124CQ ARD55105C ARD55112C ARD55124C ARD55105CQ ARD55112CQ ARD55124CQ Note: Standard packing; Carton: 1 pc. Case: 10 pcs. 2. Transfer Operating function Fail-safe Latching Latching with TTL driver (with self cut-off function) Nominal operating voltage 4.5 V DC 12 V DC 24 V DC 4.5 V DC 12 V DC 24 V DC 5 12 24 V DC V DC V DC 18GHz type No HF datasheet attached HF datasheet attached ARD2004H ARD2004HQ ARD20012 ARD20012Q ARD20024 ARD20024Q ARD2204H ARD2204HQ ARD22012 ARD22012Q ARD22024 ARD22024Q ARD25105 ARD25112 ARD25124 26.5GHz type No HF datasheet attached HF datasheet attached ARD6004H ARD6004HQ ARD60012 ARD60012Q ARD60024 ARD60024Q ARD6204H ARD6204HQ ARD62012 ARD62012Q ARD62024 ARD62024Q ARD25105Q ARD25112Q ARD25124Q ARD65105 ARD65112 ARD65124 ARD65105Q ARD65112Q ARD65124Q Note: Standard packing; Carton: 1 pc. Case: 10 pcs. 3. SP6T Operating function Fail-safe Latching Nominal operating voltage 4.5 V DC 12 V DC 24 V DC 4.5 V DC 12 V DC 24 V DC 13GHz type No HF datasheet attached ARD3004H ARD30012 ARD30024 ARD3204H ARD32012 ARD32024 HF datasheet attached ARD3004HQ ARD30012Q ARD30024Q ARD3204HQ ARD32012Q ARD32024Q Note: Standard packing; Carton: 1 pc. Case: 5 pcs. –2– ASCTB103E 201411-T RD (ARD) 4. SP6T (with termination) Operating function Nominal operating voltage 4.5 V DC 12 V DC 24 V DC 4.5 V DC 12 V DC 24 V DC Fail-safe Latching 13GHz type No HF datasheet attached ARD3004HZ ARD30012Z ARD30024Z ARD3204HZ ARD32012Z ARD32024Z HF datasheet attached ARD3004HZQ ARD30012ZQ ARD30024ZQ ARD3204HZQ ARD32012ZQ ARD32024ZQ Note: Standard packing; Carton: 1 pc. Case: 5 pcs. RATING 1. Coil data (1) SPDT 1) Fail-safe type Nominal operating voltage 4.5 V DC 12 V DC 24 V DC Nominal operating current (+10%/–15%) (at 20°C 68°F) With indicator Without indicator 186.7 mA 155.6 mA 70.0 mA 58.3 mA 38.8 mA 29.2 mA Nominal power consumption With indicator Without indicator Nominal operating current (+10%/–15%) (at 20°C 68°F) With indicator Without indicator 133.3 mA 111.1 mA 50.0 mA 41.7 mA 25.8 mA 16.7 mA Nominal power consumption With indicator Without indicator 600 mW 600 mW 500 mW 620 mW 840 mW 700 mW 930 mW 2) Latching type Nominal operating voltage 4.5 V DC 12 V DC 24 V DC 3) Latching with TTL driver type Nominal operating voltage 5 V DC 12 24 V DC V DC TTL logic level (see TTL logic level range) ON OFF 2.4 to 5.5 V 0 to 0.5 V Electronic self cut-off Switching frequency Available Max. 180 cpm (ON time : OFF time = 1 : 1) (2) Transfer 1) Fail-safe type Nominal operating voltage 4.5 V DC 12 V DC 24 V DC Nominal operating current (+10%/–15%) (at 20°C 68°F) 342.2 mA 128.3 mA 67.92 mA Nominal power consumption Nominal operating current (+10%/–15%) (at 20°C 68°F) 244.4 mA 91.7 mA 46.7 mA Nominal power consumption 1,100 mW 1,100 mW 1,120 mW 1,540 mW 1,630 mW 2) Latching type Nominal operating voltage 4.5 V DC 12 V DC 24 V DC 3) Latching with TTL driver type (with self cut-off function) Nominal operating voltage 5 V DC 12 24 V DC V DC TTL logic level (see TTL logic level range) ON OFF 2.4 to 5.5 V 0 to 0.5 V Electronic self cut-off Switching frequency Available Max. 180 cpm (ON time : OFF time = 1 : 1) (3) SP6T and SP6T (with termination type) 1) Fail-safe type Nominal operating voltage 4.5 V DC 12 V DC 24 V DC Nominal operating current (+10%/–15%) (at 20°C 68°F) 186.7 mA 70.0 mA 38.8 mA Nominal power consumption Nominal operating current (+10%/–15%) (at 20°C 68°F) SET: 133.3 mA / RESET (ALL): 800 mA SET: 50.0 mA / RESET (ALL): 300 mA SET: 25.8 mA / RESET (ALL): 155 mA Nominal power consumption SET: 600 mW / RESET (ALL): 3,600 mW SET: 600 mW / RESET (ALL): 3,600 mW SET: 620 mW / RESET (ALL): 3,720 mW 840 mW 930 mW 2) Latching type Nominal operating voltage 4.5 V DC 12 V DC 24 V DC –3– ASCTB103E 201411-T RD (ARD) Voltage VDC • Operating voltage range 1) Fail-safe type 2) Latching type 3) Latching with TTL driver type (with self cut-off function) 4.5 12 24 V V V 6 16 32 4.5 12 24 V V V 6 16 32 5 12 24 V V V 6.67 16 32 5.25 14 28 5.25 14 28 5.83 14 28 4.5 12 24 4.5 12 24 5 12 24 3.75 10 20 3.75 10 20 Nominal voltage 2.25 6 12 1.5 4 8 0.75 2 4 0 0 –55–40 –20 0 Allowable range for use Recommended operation voltage range Recommended release voltage range 20 40 60 Nominal voltage 3 8 16 2.25 6 12 1.5 4 8 Allowable range for use 1.67 4 8 Allowable range for use 0.75 2 4 Recommended set/reset voltage range 0.83 2 4 Recommended set/reset voltage range 0 0 0 –55–40 –20 0 0 4.17 10 20 Nominal voltage 8 16 3 85 Ambient temperature °C 0 0 –55–40 –20 0 20 40 60 Ambient temperature °C 85 3.33 8 16 2.5 6 12 0 20 40 60 Ambient temperature °C 85 4) TTL Logic level range 5.5 Voltage VDC 5 4 3 2.4 2 1 ON OFF 0.5 0 –55–40 –20 0 20 40 60 Ambient temperature °C 85 Note: Please consult us for use that is outside this range. –4– ASCTB103E 201411-T RD (ARD) 2. Specifications 1) SPDT/Transfer Characteristics Contact Item Arrangement Contact material Initial contact resistance Contact input power Rating Nominal operating power Indicator rating (with indicator type only) Fail-safe Latching Contact rating Initial contact resistance Min. switching capacity (Reference value) Specifications SPDT Transfer Gold plating Max. 100mΩ (By voltage drop 6V DC 1A) 120W (at 3GHz) (V.S.W.R. 1.15 or less, no contact switching, ambient temperature 40°C 104°F [SPDT], 25°C 77°F [Transfer])*1 840mW (4.5V, 12V DC), 930mW (24V DC) 1,540mW (4.5V, 12V DC), 1,630mW (24V DC) 600mW (4.5V DC), 600mW (12V DC), 1,100mW (4.5V DC), 1,100mW (12V DC), 620mW (24V DC) 1,120mW (24V DC) Max. 30V 100mA Max. 1Ω (Measured by 5V 100mA) 3V DC, 0.1mA (5 × 106, Reliability level: 10% (3kΩ)) to 1 GHz High frequency characteristics (Impedance 50Ω) V.S.W.R. (max.) Insertion loss (dB, max.) Isolation (dB, min.) Insulation resistance (Initial) Electrical characteristics Time characteristics (at 20°C 68°F) Mechanical characteristics Breakdown voltage (Initial) Shock resistance Functional Destructive Vibration resistance Functional Destructive Mechanical Electrical 4 to 8 GHz*2 8 to 12.4 GHz 12.4 to 18 GHz 1.15 1.25 0.3 70 1.35 0.4 65 1.5 0.5 60 1.1 0.2 85 80 High frequency contact (Hot switch) 500 Vrms for 1 min. (Detection current: 10mA) 500 Vrms for 1 min. (Detection current: 10mA) 500 Vrms for 1 min. (Detection current: 10mA) 500 Vrms for 1 min. (Detection current: 10mA) Max. 15ms (Nominal operating voltage applied to Max. 20ms (Nominal operating voltage applied to the coil, excluding contact bounce time.) the coil, excluding contact bounce time.) Min. 500 m/s2 (Half-wave pulse of sine wave: 11ms, detection time: 10μs.) Min. 1,000 m/s2 (Half-wave pulse of sine wave: 11ms.) 10 to 55 Hz at double amplitude of 3mm (Detection time: 10μs.) 10 to 55 Hz at double amplitude of 5mm 6GHz type: Min. 106 Min. 5 × 106 18 and 26.5GHz type: Min. 5 × 106 (at 180 cpm) (All types, at 180 cpm) 6GHz type: Min. 106 Min. 5 × 106 18 and 26.5GHz type: Min. 5 × 106 (5W to 3GHz, impedance 50Ω, V.S.W.R.; max. 1.2) (All types, 5W to 3GHz, impedance 50Ω, (at 20 cpm) V.S.W.R.; max. 1.2) (at 20 cpm) Indicator (with indicator type only) Conditions Unit weight Notes: *1 *2 *3 *4 Conditions for operation, transport and storage*4 18 to 26.5 GHz*3 1.7 0.8 55 Min. 1,000 MΩ (at 500 V DC) Measurement at same location as “breakdown voltage (Initial)” section. Between open contacts Between contact and coil Between contact and earth terminal Between coil and earth terminal Operate time Expected life 1 to 4 GHz 5 V DC, 10 mA, Min. 106 (at 20 cpm) Ambient temperature: –55°C to +85°C –67°F to +185°F Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Approx. 50g 1.76oz Approx. 110g 3.88oz Factors such as heating of the connected connector influence the high frequency characteristics; therefore, please verify under actual conditions of use. The 6GHz type only has the above characteristics up to 6GHz. 18 to 26.5GHz characteristics can be applied 26.5GHz type only (SPDT, Transfer) The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to “AMBIENT ENVIRONMENT” in GENERAL APPLICATION GUIDELINES. –5– ASCTB103E 201411-T RD (ARD) 2) SP6T Characteristics Contact Rating Indicator rating High frequency characteristics (Impedance 50Ω) Item Arrangement Contact material Initial contact resistance Contact input power No termination With termination Nominal operating power Fail-safe 840mW (4.5V, 12V DC), 930mW (24V DC) Time characteristics (at 20°C 68°F) Mechanical characteristics 120 W (at 3GHz) (V.S.W.R. 1.15 or less, no contact switching, ambient temperature 25°C 77°F)*1 2W (at 3GHz) (V.S.W.R. 1.15 or less, no contact switching, ambient temperature 25°C 77°F)*1 Latching 600mW (4.5V DC), 600mW (12V DC), 620mW (24V DC) Contact rating Initial contact resistance Min. switching capacity (Reference value) No termination With termination Insertion loss (dB, max.) Isolation (dB, min.) V.S.W.R. (max.) Insulation resistance (Initial) Electrical characteristics Specifications SP6T Gold plating Max. 100mΩ (By voltage drop 6V DC 1A) Breakdown voltage (Initial) Max. 30V 100mA Max. 1Ω (Measured by 5V 100mA) 3V DC, 0.1mA (5 × 106, Reliability level: 10% (3kΩ)) to 1 GHz 1 to 4 GHz 4 to 8 GHz 8 to 12.4 GHz 12.4 to 18 GHz 1.1 1.15 1.25 1.40 0.3 70 1.35 1.50 0.4 65 1.50 1.50 1.0 60 1.20 0.2 85 80 Min. 1,000 MΩ (at 500 V DC) Measurement at same location as “breakdown voltage (Initial)” section. Between open contacts Between contact and coil Between contact and earth terminal Between coil and earth terminal Operate time 500 Vrms for 1 min. (Detection current: 10mA) 500 Vrms for 1 min. (Detection current: 10mA) 500 Vrms for 1 min. (Detection current: 10mA) 500 Vrms for 1 min. (Detection current: 10mA) Max. 20ms (Nominal operating voltage applied to the coil, excluding contact bounce time.) Shock resistance Functional Destructive Vibration resistance Functional Destructive Min. 500 m/s2 (Half-wave pulse of sine wave: 11ms, detection time: 10μs.) Min. 1,000 m/s2 (Half-wave pulse of sine wave: 11ms.) Mechanical Expected life Electrical High frequency contact (Hot switch) No termination With termination 10 to 55 Hz at double amplitude of 3mm (Detection time: 10μs.) 10 to 55 Hz at double amplitude of 5mm Min. 5 × 106 (at 180 cpm) Min. 5 × 106 (5W to 3GHz, impedance 50Ω, V.S.W.R.; max. 1.2) (at 20 cpm) Min. 5 × 106 (2W to 3GHz, impedance 50Ω, V.S.W.R.; max. 1.2) (at 20 cpm) Indicator (with indicator type only) Conditions Unit weight Conditions for operation, transport and storage*2 5 VDC, 10 mA, Min. 106 (at 20 cpm) Ambient temperature: –55°C to +85°C –67°F to +185°F Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Approx. 320g 11.29oz Notes: *1 Factors such as heating of the connected connector influence the high frequency characteristics; therefore, please verify under actual conditions of use. *2 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to “AMBIENT ENVIRONMENT” in GENERAL APPLICATION GUIDELINES. –6– ASCTB103E 201411-T RD (ARD) REFERENCE DATA 1-(1). High frequency characteristics (SPDT) 6GHz type Sample: ARD70012 Measuring method: Measured with Agilent Technologies network analyzer (E8363B). • Insertion loss • Isolation 1.9 0 0 1.8 0.1 10 1.7 0.2 1.5 1.4 Standard value 20 0.3 Reference value Standard value 0.4 0.5 Isolation, dB 1.6 Insertion loss, dB V.S.W.R. • V.S.W.R. 30 40 50 0.6 60 0.7 70 1.1 0.8 80 1.0 0.9 1.3 Reference value 1.2 30MHz 1GHz 4GHz 6GHz Frequency Reference value 90 1.0 30MHz 1GHz 8GHz Standard value 4GHz 6GHz Frequency 100 30MHz 1GHz 8GHz 4GHz 6GHz Frequency 8GHz 1-(2). High frequency characteristics (SPDT) 18, 26.5GHz type Sample: ARD10012 Measuring method: Measured with Agilent Technologies network analyzer (HP8510). • Insertion loss • Isolation 1.9 0 0 1.8 0.1 10 1.7 0.2 20 0.3 30 Standard value 1.5 1.4 Reference value 1.3 Reference value Isolation, dB 1.6 Insertion loss, dB V.S.W.R. • V.S.W.R. 0.4 0.5 Standard value 0.6 40 60 1.2 0.7 70 1.1 0.8 80 1.0 0.9 90 1.0 100 1GHz 4GHz 8GHz 12.4GHz 18GHz Frequency 26.5GHz 1GHz 4GHz 8GHz 12.4GHz 18GHz Frequency Standard value 50 26.5GHz Reference value 1GHz 4GHz 8GHz 12.4GHz 18GHz Frequency 26.5GHz 1-(3). High frequency characteristics (Transfer) Sample: ARD60012 Measuring method: Measured with Agilent Technologies network analyzer (HP8510). • V.S.W.R. • Insertion loss 0 1.8 0.1 10 1.6 Standard value 1.5 1.4 1.3 Reference value Reference value 0.2 20 0.3 30 Isolation, dB Insertion loss, dB 0 1.7 V.S.W.R. • Isolation 1.9 0.4 0.5 0.6 Standard value 40 Standard value 50 60 1.2 0.7 70 1.1 0.8 80 1.0 0.9 90 1.0 100 1GHz 4GHz 8GHz 12.4GHz 18GHz Frequency 26.5GHz 1GHz 4GHz 8GHz 12.4GHz 18GHz Frequency –7– 26.5GHz Reference value 1GHz 4GHz 8GHz 12.4GHz 18GHz Frequency 26.5GHz ASCTB103E 201411-T RD (ARD) 1-(4). High frequency characteristics (SP6T) Sample: ARD30012 Measuring method: Measured with Agilent Technologies network analyzer (HP8510). • V.S.W.R. • Insertion loss 0 1.9 0.1 10 1.7 1.6 1.5 Standard value 1.4 20 0.3 30 0.4 0.5 Standard value 0.6 1.3 Reference value 1.2 Reference value 0.2 Isolation, dB Insertion loss, dB 0 1.8 V.S.W.R. • Isolation 2.0 40 50 0.7 70 0.8 80 1.1 0.9 90 1.0 1.0 100 1GHz 4GHz 8GHz 12.4GHz Frequency 18GHz 1GHz 4GHz 8GHz 12.4GHz Frequency 18GHz Standard value 60 Reference value 1GHz 4GHz 8GHz 12.4GHz Frequency 18GHz • Termination characteristics 2.0 1.9 V.S.W.R. 1.8 1.7 1.6 1.5 Standard value Reference value 1.4 1.3 1.2 1.1 1.0 1GHz 4GHz 8GHz 12.4GHz Frequency 18GHz –8– ASCTB103E 201411-T RD (ARD) DIMENSIONS (mm inch) The CAD data of the products with a CAD Data 1. SPDT 1) Solder terminal 3.5 .138 3.5 .138 2.0 .079 CAD Data 4.3 .169 mark can be downloaded from: http://industrial.panasonic.com/ac/e/ 11.2 .441 Solder terminal NC COM NO Indicator Coil GND + 40.0 1.575 7.0 .276 0.3 .012 3.5 .138 Serial No. 4.5 .177 2-3.1 dia. 2-.122 dia. 2-2.4 dia. 2-.094 dia. 7.2 .283 6GHz type 7.3 .287 2.1 .083 3-SMA connector 11.2 .441 22.4 .882 30.0 1.181 34.0 1.339 13.2 .520 18 and 26.5GHz types Tolerance: ±0.3 ±.012 Fail-safe Latching 1 COM NC COM NO 2 Latching with TTL driver (with self cut-off function) 1 COM 2 Indicator terminal GND + Coil terminal + V GND Logic 1 Logic 2 Coil 1 GND + Coil 2 NC COM NO GND + Serial No. Indicator Coil 1 COM 2 GND 1 2 Indicator Coil Serial No. 1 COM 2 V GND 1 Indicator 2 Coil Serial No. ∗ + COM type is available * The type without indicator terminals will not have the indicator terminals that are marked with the dotted box. –9– ASCTB103E 201411-T RD (ARD) 2) Connector cable CAD Data Pin No. Fail-safe Latching Latching with TTL driver 1 – – 2 NC 1 Indicator 3 COM COM 4 NO 2 5 – – 6 – – 7 GND GND Coil – 1 COM 2 – V GND 8 + 1 9 – 2 Logic 1 Logic 2 D-sub connector pin contact type 2345 Pin No. 1 6789 12.55 .494 3.05 dia. .120 dia. 25.0 .984 30.8 1.213 5.95 .234 1.2 .047 Vinyl chloride electric wire 110.0±10 4.331±.394 NC COM NO Indicator GND + 40.0 1.575 Serial No. 4.5 .177 Coil 2-3.1 dia. 2-.122 dia. 2-2.4 dia. 2-.094 dia. 7.3 2.1 .287 .083 11.2 .441 22.4 .882 30.0 1.181 3-SMA connector 7.2 .283 13.2 .520 Tolerance: ±0.3 ±.012 Fail-safe NC COM NO Latching Latching with TTL driver (with self cut-off function) 1 1 COM 2 Indicator terminal COM 2 Indicator terminal Indicator terminal Coil terminal Coil terminal Coil terminal GND V GND Logic 1 Logic 2 GND Coil 1 Coil 2 ∗ + COM type is available –10– ASCTB103E 201411-T RD (ARD) 2. Transfer CAD Data 5.08 .200 45.70 1.799 15.24 .600 Max. 5.0 .197 5.08 .200 2.00 .079 0.30 .012 5.08 .200 Solder terminal 3-3.80 dia. 3-.150 dia. Coil 20.3 .799 GND + Indicator NC COM NO 10.15 .400 9.65 40.0 .380 1.575 Serial No. J1 J3 9.65 .380 J2 J4 4-SMA connector 32.0 1.260 16.2 .638 7.2 .283 J2 J1 32.0 1.260 16.2 .638 1 to 1.5 .039 to .059 J3 J4 Tolerance: ±0.3 ±.012 55.5 2.185 J1 J2 J3 J4 NC: J1-J2, J3-J4 NO: J1-J3, J2-J4 POS1: J1-J2, J3-J4 POS2: J1-J3, J2-J4 POS1: J1-J2, J3-J4 POS2: J1-J3, J2-J4 Fail-safe Latching Latching with TTL driver Fail-safe Coil terminal GND Latching Indicator terminal NC Coil terminal GND COM 1 NO 2 Latching with TTL driver (with self cut-off function) Indicator terminal 1 COM 2 Coil terminal V GND Logic 1 Logic 2 Indicator terminal 1 COM 2 ∗ + COM type is available –11– ASCTB103E 201411-T RD (ARD) 3. SP6T CAD Data 80.0 3.150 66.0 2.598 7-5.08 7-.200 a. di a. 5 di 4. 7 4- -.17 4 25.4 66.0 80.0 1.000 2.598 3.150 Max. 4.5 Max. .177 78.0 dia. 3.071 dia. J2 J3 3.0 .118 COM1 2 3 4 5 6 Serial No. Ind Coil MADEIN JAPAN 40.50 1.594 J4 J1 COM GND 1 2 3 4 5 6 J6 J5 (Bottom view) 7.2 .283 J2 J3 56 .0 2.2 dia. 05 dia . J1 7-SMA jack connector J4 COM J6 J5 Tolerance: ±0.3 ±.012 Fail-safe type Coil terminal GND 1 Indicator terminal COM 1 Latching type 2 6 2 COM J1 Coil terminal GND 1 Indicator terminal COM 1 6 2 J2 J6 6 COM J1 J2 J6 *RESET (ALL) COM 1 2 3 4 5 6 Indicator terminal Coil terminal GND 1 2 3 4 5 6 GND 1 2 3 4 5 6 R J2 J3 J2 J3 Serial No. MADE IN JAPAN Ind Coil *R 6 COM 1 2 3 4 5 6 Indicator terminal Coil terminal 2 J4 COM1 2 3 4 5 6 J1 GND1 2 3 4 5 6 (Bottom view) Serial No. COM J6 J5 MADE IN JAPAN Ind Coil J4 COM1 2 3 4 5 6 J1 GND1 2 3 4 5 6 R (Bottom view) COM J6 J5 ∗ + COM type is available. –12– ASCTB103E 201411-T RD (ARD) 4. SP6T (with termination) CAD Data 80.0 3.150 66.0 2.598 7-5.08 7-.200 a. di ia. 5 d 4. 77 4 -.1 4 25.4 66.0 80.0 1.000 2.598 3.150 Max. 4.5 Max. .177 J2 J3 Serial No. 3.0 .118 MADE IN JAPAN 40.50 1.594 J4 J1 COM 1 2 3 4 5 6 Ind Coil GND 1 2 3 4 5 6 COM J6 J5 (Bottom view) 7.2 .283 J3 J2 56.0 2.20 dia. 5 dia . 7-SMA jack connector 6-termination J1 J4 COM J6 J5 Tolerance: ±0.3 ±.012 Fail-safe type Coil terminal GND 1 Indicator terminal COM 1 Indicator terminal Coil terminal 2 6 2 COM J1 Latching type Coil terminal GND 1 Indicator terminal COM 1 2 2 6 6 6 J2 J6 COM J1 COM 1 2 3 4 5 6 Indicator terminal Coil terminal GND 1 2 3 4 5 6 J2 Ind Coil GND 1 2 3 4 5 6 R J2 J3 J4 COM1 2 3 4 5 6 J1 GND 1 2 3 4 5 6 (Bottom view) COM J6 J5 J6 COM 1 2 3 4 5 6 J2 J3 Serial No. MADE IN JAPAN R Serial No. MADE IN JAPAN Ind Coil J4 COM1 2 3 4 5 6 J1 GND 1 2 3 4 5 6 R (Bottom view) COM J6 J5 –13– ASCTB103E 201411-T RD (ARD) NOTES 1. For general cautions for use, please refer to the “General Application Guidelines”. 2. Coil operating power Pure DC current should be applied to the coil. The wave form should be rectangular. If it includes ripple, the ripple factor should be less than 5%. However, check it with the actual circuit since the characteristics may be slightly different. The nominal operating voltage should be applied to the coil for more than 50 ms to set/reset the latching type relay. Please use the latching type for circuits that are continually powered for long periods of time. 3. Coil connection When connecting coils, refer to the wiring diagram to prevent mis-operation or malfunction. 4. Connection of coil indicator and washing conditions 1) The connection of coil indicator terminal shall be done by soldering. Soldering conditions Max. 260°C 500°F (solder temp) within 10sec (soldering time) Max. 350°C 662°F (solder temp) within 3sec (soldering time) 2) This product is not sealed type, therefore washing is not allowed. 5. Conditions for operation, transport and storage conditions 1) Temperature: –55 to +85°C –67 to +185°F 2) Humidity: 5 to 85% RH (Avoid freezing and condensation.) The humidity range varies with the temperature. Use within the range indicated in the graph below. 3) Atmospheric pressure: 86 to 106 kPa Temperature and humidity range for usage, transport, and storage: Humidity, %RH 85 Tolerance range (Avoid freezing when (Avoid used at temperatures condensation when lower than 0°C 32°F) used at temperatures higher than 0°C 32°F) 5 –55 –67 0 +32 Temperature, °C °F +85 +185 4) Condensation Condensation forms when there is a sudden change in temperature under high temperature and high humidity conditions. Condensation will cause deterioration of the relay insulation. 5) Freezing Condensation or other moisture may freeze on the relay when the temperature is lower than 0°C 32°F. This causes problems such as sticking of movable parts or operational time lags. 6) Low temperature, low humidity environments. The plastic may become brittle if the relay is exposed to a low temperature, low humidity environment for long periods of time. 6. Other handling precautions. 1) The relay’s on/off service life is based on standard test conditions (temperature: 15 to 35°C 59 to 95°F, humidity: 25 to 75%) specified in JIS C5442-1996. Life will depend on many factors of your system: coil drive circuit, type of load, switching intervals, switching phase, ambient conditions, to name a few. 2) Use the relay within specifications such as coil rating, contact rating and on/ off service life. If used beyond limits, the relay may overheat, generate smoke or catch fire. 3) Be careful not to drop the relay. If accidentally dropped, carefully check its appearance and characteristics before use. 4) Be careful to wire the relay correctly. Otherwise, malfunction, overheat, fire or other trouble may occur. 5) The latching type relay is shipped in the reset position. But jolts during transport or impacts during installation can move it to the set position. It is, therefore, advisable to build a circuit in which the relay can be initialized (set and reset) just after turning on the power. 6) If a relay stays on in a circuit for many months or years at a time without being activated, circuit design should be reviewed so that the relay can remain non-excited. A coil that receives current all the time heats, which degrades insulation earlier than expected. A latching type relay is recommended for such circuits. –14– 7) For SMA connectors, we recommend a torque of 0.90±0.1 N·m for installation, which falls within the prescribed torque of MIL-C-39012. Please be aware that conditions might be different depending on the connector materials and how it interacts with surrounding materials. 8) Please do not use silicon based substances such as silicon rubber, silicon oil, silicon coatings and silicon fillings, in the vicinity of the relay. Doing so may cause volatile silicon gas to form which may lead to contact failure due to the adherence of silicon on the contacts when they open and close in this atmosphere. 9) Please note that when switching contacts (latching type only), you must apply reset (ALL) voltage and release all contacts first. (SP6T type) 10) Do not use multiple contacts simultaneously. (SP6T type) 11) The indicator terminal is the terminal that indicates the operation status of the MAIN contact. 12) For details about the drive method of the latching with TTL driver type, please refer to the RD coaxial switch catalog on the website. ASCTB103E 201411-T Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Panasonic: ARD10012 ARD10012C ARD10012Q ARD10024 ARD10024Q ARD1004H ARD12012 ARD12012Q ARD12024 ARD12024Q ARD1204H ARD15105 ARD15105C ARD15105Q ARD15112 ARD15112Q ARD15124 ARD15124Q ARD20012 ARD22012 ARD22012Q ARD25105Q ARD30012 ARD50012 ARD50012Q ARD50024 ARD50024Q ARD52012 ARD52012Q ARD52024 ARD52024Q ARD55112 ARD55112Q ARD55124 ARD55124Q ARD65124Q ARD3204H ARD3004H ARD25124Q ARD3004HQ