Transcript
26.5 GHz max. Coaxial switches coming in SPDT, Transfer, and SP6T types
6GHz type
FEATURES
TYPICAL APPLICATIONS
1. Excellent high frequency characteristics (50Ω, to 26.5Ghz) 2. SPDT, Transfer and SP6T types are available. 3. High sensitivity Nominal operating power: 840 mW (SPDT/SP6T, Fail-safe type, with indicator) 1,540 mW (Transfer, Fail-safe type, with indicator)
Wireless and mobile communication • Cellular phone base station • Amplifier switching Digital broadcasting • Broadcasting relay station • Broadcasting equipment High frequency measuring market All types of inspection equipment
*Without 24V type
4. Long-lasting life: min. 5 × 106 5. With termination type is added. (SP6T) Thanks to the addition of termination, steady high frequency characteristics can be maintained when contacts are either open or closed and this contributes to increase system reliability.
RoHS compliant
RD COAXIAL SWITCHES (ARD)
If you consider using applications with low level loads or with high frequency switching, please consult us.
HIGH FREQUENCY CHARACTERISTICS (Impedance 50Ω) Frequency V.S.W.R. (max.) V.S.W.R. (SP6T With termination) (max.) Insertion loss (dB. max.) Isolation (dB. min.)
to 1 GHz 1.1
1 to 4 GHz 1.15 1.20 0.2
85
80
4 to 8 GHz*1 1.25 1.40 0.3 70
8 to 12.4 GHz 1.35 1.50 0.4 65
12.4 to 18 GHz 1.5 — 0.5 60
18 to 26.5 GHz*2 1.7 — 0.8 55
Notes: *1 The 6GHz type only has the above characteristics up to 6GHz. *2 18 to 26.5GHz characteristics can be applied 26.5GHz type only (SPDT, Transfer)
ORDERING INFORMATION ARD RD coaxial switches Frequency 1: to 18GHz (SPDT) 2: to 18GHz (Transfer) 3: to 13GHz (SP6T)
5: to 26.5GHz (SPDT) 6: to 26.5GHz (Transfer) 7: to 6GHz (SPDT)
Operating function 00: Fail-safe (with indicator) 20: Latching (with indicator) 51: Latching with TTL driver (SPDT, Transfer) (with self cut-off function) (with indicator)
02: Fail-safe (without indicator) 22: Latching (without indicator) 53: Latching with TTL driver (SPDT) (with self cut-off function) (without indicator)
Nominal operating voltage, V DC 4H: 4.5 (Fail-safe, Latching type only) 05: 5 (Latching with TTL driver type only)
12: 12 24: 24
Operation terminal Nil: Solder terminal C: Connector cable (SPDT type only) Termination (SP6T type only) Nil: No termination Z: With termination HF data attached Nil: No HF test data attached Q: HF test data attached Note: Sealed types also available, please consult us (SPDT only)
–1–
ASCTB103E 201411-T
RD (ARD) TYPES 1. SPDT 1) Solder terminal Operating function
Fail-safe (with indicator) Latching (with indicator) Latching with TTL driver (with self cut-off function) (with indicator) Fail-safe (without indicator) Latching (without indicator) Latching with TTL driver (with self cut-off function) (without indicator)
Nominal operating voltage
6GHz type No HF datasheet attached
18GHz type No HF datasheet HF datasheet attached attached
26.5GHz type No HF datasheet HF datasheet attached attached
4.5 V DC 12 V DC 24 V DC
ARD7004H ARD70012 ARD70024
ARD1004H ARD10012 ARD10024
ARD1004HQ ARD10012Q ARD10024Q
ARD5004H ARD50012 ARD50024
ARD5004HQ ARD50012Q ARD50024Q
4.5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC
ARD7204H ARD72012 ARD72024 ARD75105 ARD75112 ARD75124
ARD1204H ARD12012 ARD12024 ARD15105 ARD15112 ARD15124
ARD1204HQ ARD12012Q ARD12024Q ARD15105Q ARD15112Q ARD15124Q
ARD5204H ARD52012 ARD52024 ARD55105 ARD55112 ARD55124
ARD5204HQ ARD52012Q ARD52024Q ARD55105Q ARD55112Q ARD55124Q
4.5 V DC 12 V DC 24 V DC
ARD7024H ARD70212 ARD70224
—
—
—
—
4.5 V DC 12 V DC 24 V DC 5 V DC 12 V DC 24 V DC
ARD7224H ARD72212 ARD72224 ARD75305 ARD75312 ARD75324
—
—
—
—
—
—
—
—
Note: Standard packing; Carton: 1 pc. Case: 20 pcs.
2) Connector cable Operating function
Fail-safe
Latching
Latching with TTL driver (with self cut-off function)
Nominal operating voltage 4.5 V DC 12 V DC 24 V DC 4.5 V DC 12 V DC 24 V DC 5 12 24
V DC V DC V DC
18GHz type No HF datasheet attached HF datasheet attached ARD1004HC ARD1004HCQ ARD10012C ARD10012CQ ARD10024C ARD10024CQ ARD1204HC ARD1204HCQ ARD12012C ARD12012CQ ARD12024C ARD12024CQ ARD15105C ARD15112C ARD15124C
26.5GHz type No HF datasheet attached HF datasheet attached ARD5004HC ARD5004HCQ ARD50012C ARD50012CQ ARD50024C ARD50024CQ ARD5204HC ARD5204HCQ ARD52012C ARD52012CQ ARD52024C ARD52024CQ
ARD15105CQ ARD15112CQ ARD15124CQ
ARD55105C ARD55112C ARD55124C
ARD55105CQ ARD55112CQ ARD55124CQ
Note: Standard packing; Carton: 1 pc. Case: 10 pcs.
2. Transfer Operating function
Fail-safe
Latching
Latching with TTL driver (with self cut-off function)
Nominal operating voltage 4.5 V DC 12 V DC 24 V DC 4.5 V DC 12 V DC 24 V DC 5 12 24
V DC V DC V DC
18GHz type No HF datasheet attached HF datasheet attached ARD2004H ARD2004HQ ARD20012 ARD20012Q ARD20024 ARD20024Q ARD2204H ARD2204HQ ARD22012 ARD22012Q ARD22024 ARD22024Q ARD25105 ARD25112 ARD25124
26.5GHz type No HF datasheet attached HF datasheet attached ARD6004H ARD6004HQ ARD60012 ARD60012Q ARD60024 ARD60024Q ARD6204H ARD6204HQ ARD62012 ARD62012Q ARD62024 ARD62024Q
ARD25105Q ARD25112Q ARD25124Q
ARD65105 ARD65112 ARD65124
ARD65105Q ARD65112Q ARD65124Q
Note: Standard packing; Carton: 1 pc. Case: 10 pcs.
3. SP6T Operating function
Fail-safe
Latching
Nominal operating voltage 4.5 V DC 12 V DC 24 V DC 4.5 V DC 12 V DC 24 V DC
13GHz type No HF datasheet attached ARD3004H ARD30012 ARD30024 ARD3204H ARD32012 ARD32024
HF datasheet attached ARD3004HQ ARD30012Q ARD30024Q ARD3204HQ ARD32012Q ARD32024Q
Note: Standard packing; Carton: 1 pc. Case: 5 pcs.
–2–
ASCTB103E 201411-T
RD (ARD) 4. SP6T (with termination) Operating function
Nominal operating voltage 4.5 V DC 12 V DC 24 V DC 4.5 V DC 12 V DC 24 V DC
Fail-safe
Latching
13GHz type No HF datasheet attached ARD3004HZ ARD30012Z ARD30024Z ARD3204HZ ARD32012Z ARD32024Z
HF datasheet attached ARD3004HZQ ARD30012ZQ ARD30024ZQ ARD3204HZQ ARD32012ZQ ARD32024ZQ
Note: Standard packing; Carton: 1 pc. Case: 5 pcs.
RATING 1. Coil data (1) SPDT 1) Fail-safe type Nominal operating voltage 4.5 V DC 12 V DC 24 V DC
Nominal operating current (+10%/–15%) (at 20°C 68°F) With indicator Without indicator 186.7 mA 155.6 mA 70.0 mA 58.3 mA 38.8 mA 29.2 mA
Nominal power consumption With indicator Without indicator
Nominal operating current (+10%/–15%) (at 20°C 68°F) With indicator Without indicator 133.3 mA 111.1 mA 50.0 mA 41.7 mA 25.8 mA 16.7 mA
Nominal power consumption With indicator Without indicator 600 mW 600 mW 500 mW 620 mW
840 mW
700 mW
930 mW
2) Latching type Nominal operating voltage 4.5 V DC 12 V DC 24 V DC
3) Latching with TTL driver type Nominal operating voltage 5
V DC
12 24
V DC V DC
TTL logic level (see TTL logic level range) ON OFF 2.4 to 5.5 V
0 to 0.5 V
Electronic self cut-off
Switching frequency
Available
Max. 180 cpm (ON time : OFF time = 1 : 1)
(2) Transfer 1) Fail-safe type Nominal operating voltage 4.5 V DC 12 V DC 24 V DC
Nominal operating current (+10%/–15%) (at 20°C 68°F) 342.2 mA 128.3 mA 67.92 mA
Nominal power consumption
Nominal operating current (+10%/–15%) (at 20°C 68°F) 244.4 mA 91.7 mA 46.7 mA
Nominal power consumption 1,100 mW 1,100 mW 1,120 mW
1,540 mW 1,630 mW
2) Latching type Nominal operating voltage 4.5 V DC 12 V DC 24 V DC
3) Latching with TTL driver type (with self cut-off function) Nominal operating voltage 5
V DC
12 24
V DC V DC
TTL logic level (see TTL logic level range) ON OFF 2.4 to 5.5 V
0 to 0.5 V
Electronic self cut-off
Switching frequency
Available
Max. 180 cpm (ON time : OFF time = 1 : 1)
(3) SP6T and SP6T (with termination type) 1) Fail-safe type Nominal operating voltage 4.5 V DC 12 V DC 24 V DC
Nominal operating current (+10%/–15%) (at 20°C 68°F) 186.7 mA 70.0 mA 38.8 mA
Nominal power consumption
Nominal operating current (+10%/–15%) (at 20°C 68°F) SET: 133.3 mA / RESET (ALL): 800 mA SET: 50.0 mA / RESET (ALL): 300 mA SET: 25.8 mA / RESET (ALL): 155 mA
Nominal power consumption SET: 600 mW / RESET (ALL): 3,600 mW SET: 600 mW / RESET (ALL): 3,600 mW SET: 620 mW / RESET (ALL): 3,720 mW
840 mW 930 mW
2) Latching type Nominal operating voltage 4.5 V DC 12 V DC 24 V DC
–3–
ASCTB103E 201411-T
RD (ARD)
Voltage VDC
• Operating voltage range 1) Fail-safe type
2) Latching type
3) Latching with TTL driver type (with self cut-off function)
4.5 12 24 V V V 6 16 32
4.5 12 24 V V V 6 16 32
5 12 24 V V V 6.67 16 32
5.25 14 28
5.25 14 28
5.83 14 28
4.5 12 24
4.5 12 24
5 12 24
3.75 10 20
3.75 10 20 Nominal voltage
2.25
6 12
1.5
4 8
0.75
2 4 0 0 –55–40 –20
0
Allowable range for use Recommended operation voltage range Recommended release voltage range 20
40
60
Nominal voltage
3
8 16
2.25
6 12
1.5
4 8
Allowable range for use
1.67
4
8
Allowable range for use
0.75
2 4
Recommended set/reset voltage range
0.83
2
4
Recommended set/reset voltage range
0
0
0 –55–40 –20
0 0
4.17 10 20 Nominal voltage
8 16
3
85
Ambient temperature °C
0 0 –55–40 –20
0 20 40 60 Ambient temperature °C
85
3.33
8 16
2.5
6 12
0 20 40 60 Ambient temperature °C
85
4) TTL Logic level range 5.5
Voltage VDC
5
4
3 2.4 2 1
ON OFF
0.5 0 –55–40 –20
0 20 40 60 Ambient temperature °C
85
Note: Please consult us for use that is outside this range.
–4–
ASCTB103E 201411-T
RD (ARD) 2. Specifications 1) SPDT/Transfer Characteristics Contact
Item Arrangement Contact material Initial contact resistance Contact input power
Rating
Nominal operating power
Indicator rating (with indicator type only)
Fail-safe Latching
Contact rating Initial contact resistance Min. switching capacity (Reference value)
Specifications SPDT
Transfer Gold plating Max. 100mΩ (By voltage drop 6V DC 1A) 120W (at 3GHz) (V.S.W.R. 1.15 or less, no contact switching, ambient temperature 40°C 104°F [SPDT], 25°C 77°F [Transfer])*1 840mW (4.5V, 12V DC), 930mW (24V DC) 1,540mW (4.5V, 12V DC), 1,630mW (24V DC) 600mW (4.5V DC), 600mW (12V DC), 1,100mW (4.5V DC), 1,100mW (12V DC), 620mW (24V DC) 1,120mW (24V DC) Max. 30V 100mA Max. 1Ω (Measured by 5V 100mA) 3V DC, 0.1mA (5 × 106, Reliability level: 10% (3kΩ)) to 1 GHz
High frequency characteristics (Impedance 50Ω)
V.S.W.R. (max.) Insertion loss (dB, max.) Isolation (dB, min.) Insulation resistance (Initial)
Electrical characteristics
Time characteristics (at 20°C 68°F) Mechanical characteristics
Breakdown voltage (Initial)
Shock resistance
Functional Destructive
Vibration resistance
Functional Destructive
Mechanical
Electrical
4 to 8 GHz*2
8 to 12.4 GHz
12.4 to 18 GHz
1.15
1.25 0.3 70
1.35 0.4 65
1.5 0.5 60
1.1 0.2 85
80
High frequency contact (Hot switch)
500 Vrms for 1 min. (Detection current: 10mA) 500 Vrms for 1 min. (Detection current: 10mA) 500 Vrms for 1 min. (Detection current: 10mA) 500 Vrms for 1 min. (Detection current: 10mA) Max. 15ms (Nominal operating voltage applied to Max. 20ms (Nominal operating voltage applied to the coil, excluding contact bounce time.) the coil, excluding contact bounce time.) Min. 500 m/s2 (Half-wave pulse of sine wave: 11ms, detection time: 10μs.) Min. 1,000 m/s2 (Half-wave pulse of sine wave: 11ms.) 10 to 55 Hz at double amplitude of 3mm (Detection time: 10μs.) 10 to 55 Hz at double amplitude of 5mm 6GHz type: Min. 106 Min. 5 × 106 18 and 26.5GHz type: Min. 5 × 106 (at 180 cpm) (All types, at 180 cpm) 6GHz type: Min. 106 Min. 5 × 106 18 and 26.5GHz type: Min. 5 × 106 (5W to 3GHz, impedance 50Ω, V.S.W.R.; max. 1.2) (All types, 5W to 3GHz, impedance 50Ω, (at 20 cpm) V.S.W.R.; max. 1.2) (at 20 cpm)
Indicator (with indicator type only) Conditions Unit weight Notes: *1 *2 *3 *4
Conditions for operation, transport and storage*4
18 to 26.5 GHz*3 1.7 0.8 55
Min. 1,000 MΩ (at 500 V DC) Measurement at same location as “breakdown voltage (Initial)” section.
Between open contacts Between contact and coil Between contact and earth terminal Between coil and earth terminal
Operate time
Expected life
1 to 4 GHz
5 V DC, 10 mA, Min. 106 (at 20 cpm) Ambient temperature: –55°C to +85°C –67°F to +185°F Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Approx. 50g 1.76oz Approx. 110g 3.88oz
Factors such as heating of the connected connector influence the high frequency characteristics; therefore, please verify under actual conditions of use. The 6GHz type only has the above characteristics up to 6GHz. 18 to 26.5GHz characteristics can be applied 26.5GHz type only (SPDT, Transfer) The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to “AMBIENT ENVIRONMENT” in GENERAL APPLICATION GUIDELINES.
–5–
ASCTB103E 201411-T
RD (ARD) 2) SP6T Characteristics Contact
Rating
Indicator rating
High frequency characteristics (Impedance 50Ω)
Item Arrangement Contact material Initial contact resistance Contact input power
No termination With termination
Nominal operating power
Fail-safe
840mW (4.5V, 12V DC), 930mW (24V DC)
Time characteristics (at 20°C 68°F) Mechanical characteristics
120 W (at 3GHz) (V.S.W.R. 1.15 or less, no contact switching, ambient temperature 25°C 77°F)*1 2W (at 3GHz) (V.S.W.R. 1.15 or less, no contact switching, ambient temperature 25°C 77°F)*1
Latching
600mW (4.5V DC), 600mW (12V DC), 620mW (24V DC)
Contact rating Initial contact resistance Min. switching capacity (Reference value) No termination With termination Insertion loss (dB, max.) Isolation (dB, min.) V.S.W.R. (max.)
Insulation resistance (Initial)
Electrical characteristics
Specifications SP6T Gold plating Max. 100mΩ (By voltage drop 6V DC 1A)
Breakdown voltage (Initial)
Max. 30V 100mA Max. 1Ω (Measured by 5V 100mA) 3V DC, 0.1mA (5 × 106, Reliability level: 10% (3kΩ)) to 1 GHz
1 to 4 GHz
4 to 8 GHz
8 to 12.4 GHz
12.4 to 18 GHz
1.1
1.15
1.25 1.40 0.3 70
1.35 1.50 0.4 65
1.50 1.50 1.0 60
1.20 0.2 85
80
Min. 1,000 MΩ (at 500 V DC) Measurement at same location as “breakdown voltage (Initial)” section.
Between open contacts Between contact and coil Between contact and earth terminal Between coil and earth terminal
Operate time
500 Vrms for 1 min. (Detection current: 10mA) 500 Vrms for 1 min. (Detection current: 10mA) 500 Vrms for 1 min. (Detection current: 10mA) 500 Vrms for 1 min. (Detection current: 10mA) Max. 20ms (Nominal operating voltage applied to the coil, excluding contact bounce time.)
Shock resistance
Functional Destructive
Vibration resistance
Functional Destructive
Min. 500 m/s2 (Half-wave pulse of sine wave: 11ms, detection time: 10μs.) Min. 1,000 m/s2 (Half-wave pulse of sine wave: 11ms.)
Mechanical Expected life
Electrical
High frequency contact (Hot switch)
No termination With termination
10 to 55 Hz at double amplitude of 3mm (Detection time: 10μs.) 10 to 55 Hz at double amplitude of 5mm Min. 5 × 106 (at 180 cpm) Min. 5 × 106 (5W to 3GHz, impedance 50Ω, V.S.W.R.; max. 1.2) (at 20 cpm) Min. 5 × 106 (2W to 3GHz, impedance 50Ω, V.S.W.R.; max. 1.2) (at 20 cpm)
Indicator (with indicator type only) Conditions Unit weight
Conditions for operation, transport and storage*2
5 VDC, 10 mA, Min. 106 (at 20 cpm) Ambient temperature: –55°C to +85°C –67°F to +185°F Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Approx. 320g 11.29oz
Notes: *1 Factors such as heating of the connected connector influence the high frequency characteristics; therefore, please verify under actual conditions of use. *2 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to “AMBIENT ENVIRONMENT” in GENERAL APPLICATION GUIDELINES.
–6–
ASCTB103E 201411-T
RD (ARD) REFERENCE DATA 1-(1). High frequency characteristics (SPDT) 6GHz type Sample: ARD70012 Measuring method: Measured with Agilent Technologies network analyzer (E8363B).
• Insertion loss
• Isolation
1.9
0
0
1.8
0.1
10
1.7
0.2
1.5 1.4
Standard value
20
0.3
Reference value
Standard value
0.4 0.5
Isolation, dB
1.6
Insertion loss, dB
V.S.W.R.
• V.S.W.R.
30 40 50
0.6
60
0.7
70
1.1
0.8
80
1.0
0.9
1.3
Reference value
1.2
30MHz 1GHz
4GHz 6GHz Frequency
Reference value
90
1.0 30MHz 1GHz
8GHz
Standard value
4GHz 6GHz Frequency
100 30MHz 1GHz
8GHz
4GHz 6GHz Frequency
8GHz
1-(2). High frequency characteristics (SPDT) 18, 26.5GHz type Sample: ARD10012 Measuring method: Measured with Agilent Technologies network analyzer (HP8510).
• Insertion loss
• Isolation
1.9
0
0
1.8
0.1
10
1.7
0.2
20
0.3
30
Standard value
1.5 1.4 Reference value
1.3
Reference value Isolation, dB
1.6
Insertion loss, dB
V.S.W.R.
• V.S.W.R.
0.4 0.5 Standard value
0.6
40
60
1.2
0.7
70
1.1
0.8
80
1.0
0.9
90
1.0
100
1GHz 4GHz 8GHz 12.4GHz 18GHz Frequency
26.5GHz
1GHz 4GHz 8GHz 12.4GHz 18GHz Frequency
Standard value
50
26.5GHz
Reference value 1GHz 4GHz 8GHz 12.4GHz 18GHz Frequency
26.5GHz
1-(3). High frequency characteristics (Transfer) Sample: ARD60012 Measuring method: Measured with Agilent Technologies network analyzer (HP8510).
• V.S.W.R.
• Insertion loss
0
1.8
0.1
10
1.6
Standard value
1.5 1.4 1.3
Reference value
Reference value
0.2
20
0.3
30
Isolation, dB
Insertion loss, dB
0
1.7 V.S.W.R.
• Isolation
1.9
0.4 0.5 0.6
Standard value
40 Standard value 50 60
1.2
0.7
70
1.1
0.8
80
1.0
0.9
90
1.0
100
1GHz 4GHz 8GHz 12.4GHz 18GHz Frequency
26.5GHz
1GHz 4GHz 8GHz 12.4GHz 18GHz Frequency
–7–
26.5GHz
Reference value
1GHz 4GHz 8GHz 12.4GHz 18GHz Frequency
26.5GHz
ASCTB103E 201411-T
RD (ARD) 1-(4). High frequency characteristics (SP6T) Sample: ARD30012 Measuring method: Measured with Agilent Technologies network analyzer (HP8510).
• V.S.W.R.
• Insertion loss
0
1.9
0.1
10
1.7 1.6 1.5 Standard value
1.4
20
0.3
30
0.4 0.5
Standard value
0.6
1.3 Reference value
1.2
Reference value 0.2 Isolation, dB
Insertion loss, dB
0
1.8 V.S.W.R.
• Isolation
2.0
40 50
0.7
70
0.8
80
1.1
0.9
90
1.0
1.0
100
1GHz
4GHz
8GHz 12.4GHz Frequency
18GHz
1GHz 4GHz
8GHz 12.4GHz Frequency
18GHz
Standard value
60
Reference value
1GHz
4GHz
8GHz 12.4GHz Frequency
18GHz
• Termination characteristics 2.0 1.9
V.S.W.R.
1.8 1.7 1.6 1.5 Standard value Reference value
1.4 1.3 1.2 1.1 1.0
1GHz
4GHz
8GHz 12.4GHz Frequency
18GHz
–8–
ASCTB103E 201411-T
RD (ARD) DIMENSIONS (mm inch)
The CAD data of the products with a
CAD Data
1. SPDT 1) Solder terminal 3.5 .138 3.5 .138 2.0 .079
CAD Data 4.3 .169
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
11.2 .441
Solder terminal
NC COM NO
Indicator Coil
GND +
40.0 1.575
7.0 .276 0.3 .012
3.5 .138
Serial No.
4.5 .177
2-3.1 dia. 2-.122 dia. 2-2.4 dia. 2-.094 dia.
7.2 .283
6GHz type
7.3 .287
2.1 .083
3-SMA connector
11.2 .441 22.4 .882 30.0 1.181 34.0 1.339
13.2 .520
18 and 26.5GHz types Tolerance: ±0.3 ±.012
Fail-safe
Latching
1 COM
NC COM NO
2
Latching with TTL driver (with self cut-off function) 1
COM 2 Indicator terminal
GND
+
Coil terminal
+ V GND Logic 1 Logic 2
Coil 1
GND +
Coil 2
NC COM NO GND +
Serial No.
Indicator Coil
1 COM 2 GND 1
2
Indicator Coil
Serial No.
1 COM 2 V
GND 1
Indicator 2 Coil
Serial No.
∗ + COM type is available * The type without indicator terminals will not have the indicator terminals that are marked with the dotted box.
–9–
ASCTB103E 201411-T
RD (ARD) 2) Connector cable CAD Data Pin No. Fail-safe Latching Latching with TTL driver
1 – –
2 NC 1
Indicator 3 COM COM
4 NO 2
5 – –
6 – –
7 GND GND
Coil
–
1
COM
2
–
V
GND
8 + 1
9 – 2
Logic 1 Logic 2
D-sub connector pin contact type
2345 Pin No. 1 6789 12.55 .494
3.05 dia. .120 dia.
25.0 .984 30.8 1.213
5.95 .234
1.2 .047
Vinyl chloride electric wire
110.0±10 4.331±.394
NC COM NO
Indicator
GND +
40.0 1.575
Serial No.
4.5 .177
Coil
2-3.1 dia. 2-.122 dia. 2-2.4 dia. 2-.094 dia.
7.3 2.1 .287 .083
11.2 .441 22.4 .882 30.0 1.181
3-SMA connector
7.2 .283
13.2 .520
Tolerance: ±0.3 ±.012
Fail-safe NC COM NO
Latching
Latching with TTL driver (with self cut-off function) 1
1 COM 2 Indicator terminal
COM 2 Indicator terminal
Indicator terminal
Coil terminal
Coil terminal
Coil terminal GND V GND Logic 1 Logic 2
GND
Coil 1 Coil 2
∗ + COM type is available
–10–
ASCTB103E 201411-T
RD (ARD) 2. Transfer CAD Data 5.08 .200
45.70 1.799 15.24 .600
Max. 5.0 .197
5.08 .200 2.00 .079
0.30 .012
5.08 .200 Solder terminal
3-3.80 dia. 3-.150 dia. Coil
20.3 .799
GND +
Indicator NC COM NO
10.15 .400 9.65 40.0 .380 1.575
Serial No.
J1 J3
9.65 .380
J2 J4
4-SMA connector 32.0 1.260 16.2 .638
7.2 .283
J2
J1
32.0 1.260
16.2 .638 1 to 1.5 .039 to .059 J3
J4
Tolerance: ±0.3 ±.012
55.5 2.185
J1
J2
J3
J4
NC: J1-J2, J3-J4 NO: J1-J3, J2-J4 POS1: J1-J2, J3-J4 POS2: J1-J3, J2-J4 POS1: J1-J2, J3-J4 POS2: J1-J3, J2-J4
Fail-safe Latching Latching with TTL driver
Fail-safe
Coil terminal GND
Latching
Indicator terminal NC
Coil terminal GND
COM
1
NO
2
Latching with TTL driver (with self cut-off function)
Indicator terminal 1 COM 2
Coil terminal V GND Logic 1 Logic 2
Indicator terminal 1 COM 2
∗ + COM type is available
–11–
ASCTB103E 201411-T
RD (ARD) 3. SP6T CAD Data 80.0 3.150 66.0 2.598 7-5.08 7-.200
a. di a. 5 di 4. 7 4- -.17 4
25.4 66.0 80.0 1.000 2.598 3.150
Max. 4.5 Max. .177
78.0 dia. 3.071 dia.
J2 J3
3.0 .118
COM1 2 3 4 5 6
Serial No.
Ind Coil
MADEIN JAPAN
40.50 1.594
J4
J1
COM GND 1 2 3 4 5 6
J6 J5
(Bottom view)
7.2 .283
J2
J3
56 .0 2.2 dia. 05 dia .
J1
7-SMA jack connector
J4
COM
J6
J5 Tolerance: ±0.3 ±.012
Fail-safe type Coil terminal GND 1 Indicator terminal COM 1
Latching type
2
6
2
COM J1
Coil terminal GND 1 Indicator terminal COM 1
6
2
J2
J6
6
COM J1
J2
J6 *RESET (ALL)
COM 1 2 3 4 5 6
Indicator terminal Coil terminal
GND 1 2 3 4 5 6
GND 1 2 3 4 5 6 R
J2 J3
J2 J3
Serial No.
MADE IN JAPAN
Ind Coil
*R
6
COM 1 2 3 4 5 6
Indicator terminal Coil terminal
2
J4
COM1 2 3 4 5 6
J1
GND1 2 3 4 5 6
(Bottom view)
Serial No.
COM J6 J5
MADE IN JAPAN
Ind Coil
J4
COM1 2 3 4 5 6
J1
GND1 2 3 4 5 6 R
(Bottom view)
COM J6
J5
∗ + COM type is available.
–12–
ASCTB103E 201411-T
RD (ARD) 4. SP6T (with termination) CAD Data 80.0 3.150 66.0 2.598 7-5.08 7-.200
a. di ia. 5 d 4. 77 4 -.1 4
25.4 66.0 80.0 1.000 2.598 3.150
Max. 4.5 Max. .177
J2 J3
Serial No.
3.0 .118
MADE IN JAPAN
40.50 1.594
J4
J1
COM 1 2 3 4 5 6 Ind Coil GND 1 2 3 4 5 6
COM J6 J5
(Bottom view)
7.2 .283
J3
J2 56.0 2.20 dia. 5 dia .
7-SMA jack connector 6-termination
J1
J4
COM
J6
J5
Tolerance: ±0.3 ±.012
Fail-safe type Coil terminal GND 1 Indicator terminal COM 1
Indicator terminal Coil terminal
2
6
2
COM J1
Latching type Coil terminal GND 1 Indicator terminal COM 1
2 2
6 6
6
J2
J6
COM J1
COM 1 2 3 4 5 6
Indicator terminal Coil terminal
GND 1 2 3 4 5 6
J2
Ind Coil
GND 1 2 3 4 5 6 R
J2 J3
J4
COM1 2 3 4 5 6
J1
GND 1 2 3 4 5 6
(Bottom view)
COM J6 J5
J6
COM 1 2 3 4 5 6
J2 J3
Serial No.
MADE IN JAPAN
R
Serial No.
MADE IN JAPAN
Ind Coil
J4
COM1 2 3 4 5 6
J1
GND 1 2 3 4 5 6 R
(Bottom view)
COM J6 J5
–13–
ASCTB103E 201411-T
RD (ARD) NOTES 1. For general cautions for use, please refer to the “General Application Guidelines”. 2. Coil operating power Pure DC current should be applied to the coil. The wave form should be rectangular. If it includes ripple, the ripple factor should be less than 5%. However, check it with the actual circuit since the characteristics may be slightly different. The nominal operating voltage should be applied to the coil for more than 50 ms to set/reset the latching type relay. Please use the latching type for circuits that are continually powered for long periods of time. 3. Coil connection When connecting coils, refer to the wiring diagram to prevent mis-operation or malfunction. 4. Connection of coil indicator and washing conditions 1) The connection of coil indicator terminal shall be done by soldering. Soldering conditions Max. 260°C 500°F (solder temp) within 10sec (soldering time) Max. 350°C 662°F (solder temp) within 3sec (soldering time) 2) This product is not sealed type, therefore washing is not allowed. 5. Conditions for operation, transport and storage conditions 1) Temperature: –55 to +85°C –67 to +185°F 2) Humidity: 5 to 85% RH (Avoid freezing and condensation.) The humidity range varies with the temperature. Use within the range indicated in the graph below. 3) Atmospheric pressure: 86 to 106 kPa Temperature and humidity range for usage, transport, and storage: Humidity, %RH
85 Tolerance range
(Avoid freezing when (Avoid used at temperatures condensation when lower than 0°C 32°F) used at temperatures higher than 0°C 32°F) 5 –55 –67
0 +32 Temperature, °C °F
+85 +185
4) Condensation Condensation forms when there is a sudden change in temperature under high temperature and high humidity conditions. Condensation will cause deterioration of the relay insulation. 5) Freezing Condensation or other moisture may freeze on the relay when the temperature is lower than 0°C 32°F. This causes problems such as sticking of movable parts or operational time lags. 6) Low temperature, low humidity environments. The plastic may become brittle if the relay is exposed to a low temperature, low humidity environment for long periods of time. 6. Other handling precautions. 1) The relay’s on/off service life is based on standard test conditions (temperature: 15 to 35°C 59 to 95°F, humidity: 25 to 75%) specified in JIS C5442-1996. Life will depend on many factors of your system: coil drive circuit, type of load, switching intervals, switching phase, ambient conditions, to name a few. 2) Use the relay within specifications such as coil rating, contact rating and on/ off service life. If used beyond limits, the relay may overheat, generate smoke or catch fire. 3) Be careful not to drop the relay. If accidentally dropped, carefully check its appearance and characteristics before use. 4) Be careful to wire the relay correctly. Otherwise, malfunction, overheat, fire or other trouble may occur. 5) The latching type relay is shipped in the reset position. But jolts during transport or impacts during installation can move it to the set position. It is, therefore, advisable to build a circuit in which the relay can be initialized (set and reset) just after turning on the power. 6) If a relay stays on in a circuit for many months or years at a time without being activated, circuit design should be reviewed so that the relay can remain non-excited. A coil that receives current all the time heats, which degrades insulation earlier than expected. A latching type relay is recommended for such circuits.
–14–
7) For SMA connectors, we recommend a torque of 0.90±0.1 N·m for installation, which falls within the prescribed torque of MIL-C-39012. Please be aware that conditions might be different depending on the connector materials and how it interacts with surrounding materials. 8) Please do not use silicon based substances such as silicon rubber, silicon oil, silicon coatings and silicon fillings, in the vicinity of the relay. Doing so may cause volatile silicon gas to form which may lead to contact failure due to the adherence of silicon on the contacts when they open and close in this atmosphere. 9) Please note that when switching contacts (latching type only), you must apply reset (ALL) voltage and release all contacts first. (SP6T type) 10) Do not use multiple contacts simultaneously. (SP6T type) 11) The indicator terminal is the terminal that indicates the operation status of the MAIN contact. 12) For details about the drive method of the latching with TTL driver type, please refer to the RD coaxial switch catalog on the website.
ASCTB103E 201411-T
Mouser Electronics Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Panasonic: ARD10012 ARD10012C ARD10012Q ARD10024 ARD10024Q ARD1004H ARD12012 ARD12012Q ARD12024 ARD12024Q ARD1204H ARD15105 ARD15105C ARD15105Q ARD15112 ARD15112Q ARD15124 ARD15124Q ARD20012 ARD22012 ARD22012Q ARD25105Q ARD30012 ARD50012 ARD50012Q ARD50024 ARD50024Q ARD52012 ARD52012Q ARD52024 ARD52024Q ARD55112 ARD55112Q ARD55124 ARD55124Q ARD65124Q ARD3204H ARD3004H ARD25124Q ARD3004HQ