Rdh Series Specification Sheet

   EMBED


Share

Transcript

RDH Refrigerated Air Dryers Features: ● ● Built - in air-cooled aftercooler and 1 micron filter - seperator ● ● Dual programmable timer drains ● ● Aluminum cooling technology ● ● Constant pressure hot gas by pass valve ● ● Fan pressure switch on all models ● ● Solid state contrler ● ● Oversized condensers ● ● Easy Installation ● ● Quiet continuous operation ● ● Environmentally friendly ● ● R134a refrigerant Twin Tower Engineering RDH compressed air refrigerated dyers are designed to handle high inlet air temperatures (up to 210°F). Easy to install, these all-inone units eliminate the need for a separate aftercooler, moisture separator, and particulate filter. INLET AIR TREATMENT Due to the geometric configuration of the heat exchanger, a filter of at least 1.0 micron is required. This will prevent fouling from rust, scale or other solid particulates pollutants, resulting in prolonged life of the RDH heat exchanger module. “HOT GAS” BY-PASS VALVE An innovative design, new to the industry utilizes a thermostatic bulb to control suction pressure. This ensures dryer performance regardless of load conditions and eliminates freeze-up at low loads. Calibrated at the factory, the valve never needs adjustment in the field, resulting in simpler maintenance. Maximum heat transfer is achieved in the air-to-air heat exchangers cross-flow design. The large surface areas coupled with the cross-flow of the refrigerant gases in the air-to-refrigerant exchanger ensure no liquid is returned to the refrigeration compressor. Refrigerant Discharge Refrigerant Inlet The maintenance free separator is located in the heat exchanger module. The highly efficient coalescing separator provides superior moisture separation. The large cross-section flow channel results in low velocities, producing low-pressure drop and reduced energy costs. RDH Compressed Air Refrigerated Dryer Capacity +50 Capacity +37 Electrical Power Connection ˚F Outlet PDP ˚F Outlet PDP Supply Size Model scfm scfm Dryer Dimensions NPT A in B in C in Weight lbs RDH 20 27 20 115V / 1Ph ½” 25 17 16 82 RDH 30 41 30 115V / 1Ph ½” 25 17 16 88 RDH 40 56 40 115V / 1Ph ½” 25 17 16 90 RDH 50 68 50 115V / 1Ph ½” 25 17 16 93 RDH 75 100 75 115V / 1Ph 1” 45 16 18 112 RDH 100 135 100 115V / 1Ph 1” 52 20 20 134 Standard Equipment ● ● Solid State Controller ● ● Integrated Aftercooler ● ● Integrated 1 - micron Filter/Separator ● ● Dual Timed Electric Drains with Isolating Valve and Strainer ● ● Constant Pressure Hot Gas By-Pass and Capillary Tube Controls ● ● R134a Refrigerant RDH Compressed Air Refrigerated Dryer CORRECTION FACTORS DRYPOINT Operating Pressure psig Correction Factor Inlet Air Temperature ˚F Correction factor Ambient Air Temperature ˚F Correction Factor Pressure Dew points Correction Factor ˚F 60 80 100 120 140 160 180 200 0.79 0.91 1.00 1.07 1.13 1.18 1.23 1.27 140 160 175 180 195 210 1.25 1.14 1.02 1.00 .91 0.80 80 90 100 105 110 115 122 1.22 1.11 1.00 0.94 0.89 0.83 0.78 37 40 44 50 1.00 1.06 1.29 1.36 Outlet pressure dew point 37 ˚F Max. inlet air temperature 210 ˚F Min. / max. ambient temperature 35 ˚F / 122 ˚F Max. inlet pressure 200 psig Required Pre-Filtration included Recommended Post-Filter 0.01 µm For additional information please go to our Web site @ PUREGAS, LLC 226A Commerce St. Broomfield, CO 80020 Tel 800-700-8537 Fax 303-465-9294 [email protected] RDH Refrigerated Air Dryers 7/23/13