Preview only show first 10 pages with watermark. For full document please download

Reactive Energy Management Low Voltage Capacitors Power Factor Correction

   EMBED


Share

Transcript

Power Factor Correction Reactive Energy Management Low Voltage Capacitors Complete reference of power ratings and application tables for 60 Hz networks Increase in Power Availability Enhanced safety Improve your Business Performance Make the most of your energy! Schneider Electric Capacitors Being a global specialist in Energy Management, Schneider Electric provides you the highest energy efficient, safest and most reliable Power Factor Correction solutions for your power distribution. Contents Product Overview 1 VarplusCan 2 - 9 • Range Overview & Technical Particulars • VarplusCan SDuty - Complete reference List • VarplusCan HDuty - Complete reference List • VarplusCan Dimension Details 2 3 5 8 VarplusBox 10 - 17 • Range Overview & Technical Particulars • VarplusBox HDuty - Complete reference List • VarplusBox Energy - Complete reference List • VarplusBox Dimension Details 9 11 13 14 Harmonic Application Tables 18 - 22 •Capacitor Selection Table with Detuned Reactor •VarplusCan HDuty + - Detuned Reactor + Contactor •VarplusCan Energy + - Detuned Reactor + Contactor •VarplusBox HDuty + - Detuned Reactor + Contactor •VarplusBox Energy + - Detuned Reactor + Contactor 18 19 20 21 22 Low Voltage Capacitors 60Hz Product Overview This document gives you the complete reference lists of LV Capacitors along with the Power ratings at different service voltages. Schneider Electric Power Factor Correction LV Capacitors For more detailed descriptions, VarplusCan VarplusBox VarplusCan SDuty VarplusBox HDuty Icontinous = 1.5 IN Life Exp. = 100,000 Hrs Icontinous = 1.8 IN Life Exp. = 130,000 Hrs VarplusCan HDuty VarplusBox Energy Low Voltage components Catalogue April 2011. Icontinous = 1.8 IN Life Exp. = 130,000 Hrs Icontinous = 2.5 IN Life Exp. = 160,000 Hrs 1 Low Voltage Capacitors 60Hz VarplusCan Aluminum can capacitors specially designed and engineered to deliver a long working life with low losses in standard, heavy-duty and severe operating conditions. Suitable for Fixed and Automatic PFC, real time compensation, Main features • Easy installation & maintenance • Optimized design for low weight, compactness and reliability to ensure easy installation. • Unique termination system that allows maintained tightening. • 1 point for mounting and earthing. • Vertical and horizontal position in case of Heavy Duty. Techinical Particulars Safety • Self-healing. • Pressure-sensitive disconnector on all three phases. PE90131 • • Finger-proof CLAMPTITE terminals to reduce risk of accidental • Compacity • Optimized geometric design (small dimensions and low weight). Features • High life expectancy up to 160,000 hours • Very high overload capabilities and good thermal and mechanical properties. • • Easy maintenance. • VarplusCan 2 PE90130 PE90131 PE90132 SDuty HDuty Construction Extruded aluminium can Voltage range 230 V -525 V 230 V -830 V Power range (three-phase) 1 - 30 kvar 5 - 50 kvar Peak inrush current Up to 200 x IN Up toN 250 x I Overvoltage 1.1 x UN As per IEC 60831- 1/2 Overcurrent 1.5 x IN 1.8 x IN Mean life expectancy Up to 100,000 h Up to 130,000 h Safety Self-healing + pressure-sensitive disconnector + discharge device (50V/1min) Dielectric Zn/Al alloy alloy with Wave cut & slope metallization Impregnation Non-PCB, Biodegradable soft resin Non-PCB, Biodegradable sticky resin (dry) Ambient temperature -25°C to max 55°C Protection IP20 Mounting 1- point mounting upright Terminals • Double fast-on + cable ( < 10 kvar) • CLAMPTITE - Three-phase terminal with electric shock • STUD TYPE for more than 30 kvar 1 - point mounting upright, horizontal VarplusCan SDuty Low Voltage Capacitors 50Hz Rated 240/260V Voltage Qn (kvar) Case Code Reference Number 260V @260V 230V 240V 260V @260V 2.1 2.7 4.2 5.4 6.3 8.3 10.9 2.5 3.2 4.9 6.4 7.4 9.7 12.8 5.5 2.3 2.5 3.3 5 6.5 7.5 10.0 13 3 3.8 6 7.7 8.8 11.7 15.3 6.6 38.7 HC BLRCS021A025B24 2.5 3.9 5.0 5.8 7.6 7.1 3.0 10.9 4.6 14 6.0 16.4 6.9 21.6 9.2 28.4 12 50Hz 0.9 1.5 1.8 2.3 2.7 3.8 4.5 5.6 6.8 7.5 13.5 9.4 11.3 13.5 13.5 15.1 18.1 18.8 22.6 22.6 22.6 400V 1 1.7 2 2.5 3 4.2 5 6.3 7.5 8.3 9.3 10.4 12.5 13.9 15 16.7 20 20.8 22.2 25 27.7 50Hz Qn (kvar) 3 5 7.5 10 12.5 14.3 15 16.9 18.2 20 25 26.8 28.5 30.3 In(A) Qn (kvar) 415V @400V 1.1 1.4 1.8 2.5 1.8 2.2 2.9 2.2 2.7 3.6 2.7 3.2 4.3 3.2 4.5 6.1 4.5 5.4 7.2 5.4 6.8 9.1 6.8 8.1 10.8 8.1 8.9 12 9 10.0 13.4 10.1 11.2 15 11.3 13.5 18 13.5 15.0 20.1 15.1 16.1 21.7 16.2 18 24.1 18.1 21.5 28.9 21.7 22.4 30 22.5 23.9 32.0 24.0 26.9 36.1 27.1 29.8 40.0 30.0 In(A) 3.9 6.6 9.8 13.1 16.4 18.8 19.7 22.2 23.9 26.2 32.8 35.2 37.4 39.8 8.5 50.1 HC BLRCS027A033B24 13.1 77.3 HC BLRCS042A050B24 17.0 100 LC BLRCS054A065B24 19.5 116 NC BLRCS063A075B24 26.1 152 NC BLRCS083A100B24 34.1 200 SC BLRCS109A130B24 µF Case Reference Number (X3) Code 60Hz Qn (kvar) 380V 380/400/415V µF (X3) 240V Voltage 440V In(A) 1.9 Rated Voltage Qn (kvar) 230V 10 Rated 60Hz In(A) 60Hz Qn (kvar) 3.6 6 9 12 15 17.2 18 20.3 21.8 24 30 32.2 34.2 36.4 380V 1.1 400V 1.2 2 2.4 3 3.6 5 6 7.5 9 10 11 12.5 15 17 18 20 24 25 27 30 33 In(A) 415V @400V 1.3 1.7 6.6 EC BLRCS010A012B40 2.2 2.9 11.3 DC BLRCS017A020B40 2.6 3.5 13.3 DC BLRCS020A024B40 3.2 4.3 16.6 DC BLRCS025A030B40 3.9 5.2 19.9 DC BLRCS030A036B40 5.4 7.3 27.8 HC BLRCS042A050B40 6.5 8.7 33.1 HC BLRCS050A060B40 8.1 10.8 41.8 HC BLRCS063A075B40 9.7 13 49.7 LC BLRCS075A090B40 10.7 14.4 55.0 LC BLRCS083A100B40 12.0 16 61.6 MC BLRCS093A111B40 13.4 18 68.9 MC BLRCS104A125B40 16.1 21.7 82.9 NC BLRCS125A150B40 18.0 24 92.1 NC BLRCS139A167B40 19.4 26 99.4 NC BLRCS150A180B40 21.6 28.9 111 SC BLRCS167A200B40 25.8 34.6 133 SC BLRCS200A240B40 26.9 36 138 SC BLRCS208A250B40 28.7 38.5 147 SC BLRCS222A266B40 32.3 43.3 166 SC BLRCS250A300B40 35.8 48.0 184 VC BLRCS277A332B40 µF Case In(A) (X3) Code 4.7 16.4 DC Reference Number BLRCS030A036B44 7.9 27.4 HC BLRCS050A060B44 11.8 41.1 HC BLRCS075A090B44 15.7 54.8 LC BLRCS100A120B44 19.7 68.5 NC BLRCS125A150B44 22.5 78.3 NC BLRCS143A172B44 23.6 82.2 NC BLRCS150A180B44 26.6 92.6 SC BLRCS169A203B44 28.7 99.7 SC BLRCS182A218B44 31.5 110 SC BLRCS200A240B44 39.4 137 SC BLRCS250A300B44 42.2 147 SC BLRCS268A322B44 44.9 156 SC BLRCS285A342B44 47.7 166 SC BLRCS303A364B44 3 Rated 480V Voltage Rated 525V Voltage 4 50Hz Qn (kvar) 4.2 5.2 6.7 7.5 8.8 10.4 12.5 15.5 17 18.6 20.8 25.8 28.8 31.5 33.9 50Hz Qn (kvar) 5 10.6 12.5 15.4 20 25 27.5 In(A) 5.1 6.3 8.1 9.0 10.6 12.5 15 18.6 20.4 22.4 25.0 31.0 34.6 37.9 40.8 In(A) 5.5 11.7 13.7 16.9 22 27.5 30.2 60Hz Qn (kvar) 5 6 8 9.0 10.6 12.5 15 18.6 20.4 22.3 25 31 34.6 37.8 40.7 60Hz Qn (kvar) 6 12.7 15 18.5 24 30 33 µF Case Reference Number In(A) (X3) Code 6.1 19.3 DC BLRCS042A050B48 7.5 23.9 HC BLRCS052A063B48 9.7 30.8 HC BLRCS067A080B48 10.8 34.5 HC BLRCS075A090B48 12.7 40.5 LC BLRCS088A106B48 15 47.9 MC BLRCS104A125B48 18 57.5 NC BLRCS125A150B48 22.4 71.4 NC BLRCS155A186B48 24.5 78.3 NC BLRCS170A204B48 26.8 85.6 SC BLRCS186A223B48 30 95.7 SC BLRCS208A250B48 37.2 119 SC BLRCS258A310B48 41.6 133 VC BLRCS288A346B48 45.5 145 VC BLRCS315A378B48 48.9 156 XC BLRCS339A407B48 µF Case Reference Number In(A) (X3) Code 6.6 19.2 HC BLRCS050A060B52 14.0 40.8 MC BLRCS106A127B52 16.5 48.1 NC BLRCS125A150B52 20.3 59.3 NC BLRCS154A185B52 26.4 77 SC BLRCS200A240B52 33 96.2 SC BLRCS250A300B52 36.3 106 SC BLRCS275A330B52 VarplusCan HDuty Low Voltage Capacitors 50Hz Rated 240/260V Voltage Qn (kvar) HC BLRCH021A025B24 240V 260V @260V 1.9 2.1 4.2 6.3 8.3 10.9 11.7 13.1 2.5 4.9 7.4 9.7 12.8 13.7 15.4 5.5 2.3 38.7 4.6 13.1 77.3 LC BLRCH042A050B24 16.4 6.9 19.5 116 RC BLRCH063A075B24 21.6 9 26.1 152 RC BLRCH083A100B24 28.4 12 34.1 200 TC BLRCH109A130B24 30.4 12.9 36.5 215 TC BLRCH117A140B24 34.1 14.4 3 6 8.8 11.7 15.3 16.4 18.4 6.6 10.9 2.5 5 7.5 10.0 13 14 15.7 40.9 241 TC BLRCH131A157B24 3.9 5.8 7.6 10 10.7 50Hz 60Hz Qn (kvar) 2.7 4.5 5.7 6.8 380/400/415V Code 230V 2.3 7.5 9.4 11.3 13.5 15.1 18.1 18.8 22.6 27.1 30.1 36.1 37.6 45.1 440V (X3) @260V 380V Voltage Reference Number 260V Voltage Rated In(A) Case 240V Rated Rated Qn (kvar) µF 230V 12 Voltage In(A) 60Hz 400V 2.5 3 5 6.3 7.5 8.3 10.4 12.5 15 16.7 20 20.8 25 30 33.3 40 41.7 50 50Hz Qn (kvar) 5 7.5 10 12.5 14.3 15 16.9 18.2 20 23.8 25 28.5 30.3 31.5 33.5 40 47.6 50 57.1 50Hz Qn (kvar) In(A) Qn (kvar) 415V @400V 2.7 3.6 3.2 4.3 3.2 5.4 7.2 5.4 6.8 9.1 6.8 8.1 10.8 8.1 8.9 12 9 11.2 15 11.3 13.5 18 13.5 16.1 21.7 16.2 18 24.1 18.1 28.9 21.7 22.4 30 22.5 26.9 36.1 27.1 32.3 43.3 32.5 35.8 48.1 36.1 43.1 57.7 43.3 44.9 60.2 45.2 53.8 72.2 --- 60Hz Qn (kvar) 6.6 6 9 12 15 17.2 18 20.3 21.8 24 28.6 30 34.2 13.1 16.4 18.8 19.7 22.2 23.9 26.2 31.2 32.8 37.4 39.8 41.3 44.0 52.5 62.5 65.6 74.9 In(A) 2.7 21.5 In(A) 9.8 380V 400V 3 4 6 7.5 9 10 12.5 15 18 20 24 25 30 36 40 48 50 --- In(A) µF Case (X3) Code 415V @400V 3.2 4.3 16.6 DC BLRCH025A030B40 3.9 5.2 19.9 DC BLRCH030A036B40 6.5 8.7 33.1 HC BLRCH050A060B40 10.8 41.8 HC BLRCH063A075B40 8.1 9.7 13 49.7 LC BLRCH075A090B40 10.7 14.4 55.0 LC BLRCH083A100B40 13.4 18 68.9 RC BLRCH104A125B40 16.1 21.7 82.9 RC BLRCH125A150B40 19.4 26 99.4 RC BLRCH150A180B40 21.6 28.9 111 TC BLRCH167A200B40 25.8 34.6 133 TC BLRCH200A240B40 26.9 36 138 TC BLRCH208A250B40 32.3 43.3 166 TC BLRCH250A300B40 38.8 52 199 VC BLRCH300A360B40 43 57.7 221 VC BLRCH333A400B40 51.7 69.3 265 YC BLRCH400A480B40 53.9 72.2 276 YC BLRCH417A500B40 --- --- 331 YC BLRCH500A000B40 µF Case In(A) (X3) Code Reference Number 7.9 27.4 HC 11.8 41.1 LC BLRCH050A060B44 BLRCH075A090B44 15.7 54.8 RC BLRCH100A120B44 19.7 68.5 RC BLRCH125A150B44 22.5 78.3 RC BLRCH143A172B44 23.6 82.2 RC BLRCH150A180B44 26.6 92.6 TC BLRCH169A203B44 28.7 99.7 TC BLRCH182A218B44 31.5 110 TC BLRCH200A240B44 37.5 130 TC BLRCH238A286B44 39.4 137 TC BLRCH250A300B44 44.9 156 VC BLRCH285A342B44 --- --- 166 VC BLRCH303A000B44 37.8 40.2 48 57.1 49.6 173 VC BLRCH315A378B44 52.7 184 VC BLRCH335A401B44 63 219 YC BLRCH400A480B44 75.0 261 YC BLRCH476A571B44 --- --- 274 YC BLRCH500A000B44 --- --- 313 YC BLRCH571A000B44 µF Case Reference Number (X3) Code 60Hz Qn (kvar) In(A) Reference Number 5 480V Rated 525V Voltage Rated 575V Voltage Rated 600V Voltage 6 4.2 5 7.5 8.8 10.4 11.3 12.5 13.6 14.4 15.5 17 18 19.2 20.8 22.7 25.8 28.8 31.5 33.9 36 40 50Hz 5.1 6 9 10.6 12.5 13.6 15 16.4 17.3 18.6 20.4 21.7 23 25 27 31 34.6 37.9 40.8 43.3 48.1 5 6 9 10.6 12.5 13.6 15 16.3 17.3 18.6 20.4 21.6 23 25 27 31 34.6 37.8 40.7 43.2 48 60Hz 6.1 19.3 HC BLRCH042A050B48 7.2 23 HC BLRCH050A060B48 10.8 34.5 LC BLRCH075A090B48 12.7 40.5 LC BLRCH088A106B48 15 47.9 RC BLRCH104A125B48 16.3 52 RC BLRCH113A136B48 18 57.5 RC BLRCH125A150B48 19.6 62.6 RC BLRCH136A163B48 20.8 66.3 RC BLRCH144A173B48 22.4 71.4 RC BLRCH155A186B48 24.5 78.3 TC BLRCH170A204B48 26 82.9 TC BLRCH180A216B48 28 88.4 TC BLRCH192A230B48 30 95.7 TC BLRCH208A250B48 33 104.5 TC BLRCH227A272B48 37.2 119 TC BLRCH258A310B48 41.6 133 VC BLRCH288A346B48 45.5 145 VC BLRCH315A378B48 48.9 156 XC BLRCH339A407B48 52 166 XC BLRCH360A432B48 57.7 184 XC BLRCH400A480B48 µF Case Reference Number Code Qn (kvar) In(A) Qn (kvar) In(A) (X3) 5 10 10.6 12.5 13.5 15 15.4 17.2 18.5 20 25 27.5 30.9 34.4 37.7 40 41.2 5.5 6 12 12.7 15 16.2 18 18.5 20.6 22.2 24 30 33.0 37.1 41.3 45.2 48 49.4 6.6 19.2 HC 13.2 38.5 MC BLRCH100A120B52 14 40.8 RC BLRCH106A127B52 16.5 48.1 RC BLRCH125A150B52 17.8 51.9 RC BLRCH135A162B52 19.8 57.7 RC BLRCH150A180B52 20.3 59.3 RC BLRCH154A185B52 22.7 66.2 RC BLRCH172A206B52 24.4 71.2 TC BLRCH185A222B52 26.4 77 TC BLRCH200A240B52 33 96.2 TC BLRCH250A300B52 36.3 105.8 TC BLRCH275A331B52 40.8 119 VC BLRCH309A371B52 45.4 132 VC BLRCH344A413B52 49.8 145 VC BLRCH377A452B52 52.8 154 XC BLRCH400A480B52 54.4 159 XC BLRCH412A494B52 µF Case Reference Number Code 50Hz 11.0 11.7 13.7 14.8 16.5 16.9 18.9 20.3 22 27.5 30.2 34 37.8 41.5 44 45.3 60Hz BLRCH050A060B52 Qn (kvar) In(A) Qn (kvar) In(A) (X3) 6 12 15 29.2 6 7.2 14.4 18 35 7.2 19.2 LC BLRCH060A072B57 14.5 38.5 RC BLRCH120A144B57 18.1 48.1 TC BLRCH150A180B57 35.1 93.6 VC BLRCH292A350B57 µF Case Reference Number 50Hz 12 15.1 29.3 60Hz Qn (kvar) In(A) Qn (kvar) In(A) (X3) Code 8.3 10.4 12.5 16.7 20.8 8 10 12.5 15 20 25 9.6 24.5 RC BLRCH083A100B60 12 30.6 TC BLRCH104A125B60 14.4 36.8 TC BLRCH125A150B60 19.3 49.2 VC BLRCH167A200B60 24 61.3 VC BLRCH208A250B60 10 12 16.1 20 Rated 690V Voltage Rated 830V Voltage 50Hz 60Hz µF Case Qn (kvar) In(A) Qn (kvar) In(A) (X3) Code 5.5 10 11.1 12.5 13.8 15 20 25 27.6 30 4.6 5.5 12.3 MC BLRCH055A066B69 10 22.3 RC BLRCH100A120B69 11.1 24.7 RC BLRCH111A133B69 12.6 27.8 RC BLRCH125A150B69 13.8 30.6 TC BLRCH138A165B69 15.1 33.4 TC BLRCH150A180B69 20.1 44.6 TC BLRCH200A240B69 25.1 55.7 VC BLRCH250A300B69 27.7 61.4 VC BLRCH276A331B69 25.1 6.6 12 13.3 15 16.5 18 24 30 33.1 36 30.1 66.8 VC BLRCH300A360B69 µF Case Reference Number Qn (kvar) In(A) Qn (kvar) In(A) (X3) Code 17.1 11.9 20.5 14.3 26.3 VC 50Hz 8.4 9.3 10.5 11.5 12.6 16.7 20.9 23.1 60Hz Reference Number BLRCH171A205B83 7 VarplusCan Low Voltage Capacitors 60Hz Techinical Particulars Termination cable (300 mm length) 0.5 + a Torque T = 10 Nm Toothed washer M10/M12 Hex nut M10/M12 Terminal screw M5 Terminal assembly Ht. (t) 50 mm h h 1 TS Toothed washer Hex nut VarplusCan DC, EC, FC, HC & LC 3 3 + a (expansion) 3+t 1 Finger proof CLAMPTITE terminal In-built resistor type 16 + 1 Toothed washer Hex nut Tightening Torque = 2.5 Nm 15 15 M12 M VarplusCan MC, NC, RC & SC 8 TS TH M10 10 mm Ø 63 M12 13 mm Ø 70 M12 16 mm Case code DC EC FC HC LC Diameter d (mm) 50 63 63 63 70 Height h (mm) 195 90 115 195 195 Height h+t (mm) 245 140 165 245 245 Weight (kg) 0.7 0.5 0.6 0.9 1.1 Creepage distance Clearance Expansion (a) 13 mm 13 mm max.12mm Mounting details (for M10/M12 mounting stud) h h h d Size (d) Ø 50 Case Code: RC & SC 1+5 (t) d 16 mm 16 mm max.10mm Mounting details (for M10/M12 mounting stud) TH d Creepage distance Clearance Expansion (a) 19 2 2+t FAST-ON Terminal 6.35 x 0.8 Case Code: DC, HC & LC Torque T = 10 Nm Toothed washer J12.5 DIN 6797 Hex nut BM12 DIN 439 Terminal screw M5 Terminal assembly Ht. (t) 30 mm Case code RC SC Height h (mm) 212 278 Diameter d (mm) 90 90 Height h+t (mm) 242 308 Weight (kg) 1.6 2.3 VarplusCan Low Voltage Capacitors 60Hz Case Code: TC, UC & VC 1+5 Finger proof F CLAMPTITE terminal C In-built resistor type 13 mm Clearance 13 mm Expansion (a) max.12mm 3 3 + a (expansion) 3+t 1 Mounting details (for M10/M12 mounting stud) Torque T = 10 Nm Toothed washer J12.5 DIN 6797 Hex nut BM12 DIN 439 Terminal screw M5 Terminal assembly Ht. (t) 30 mm Case code TC Diameter d (mm) 116 Height h (mm) 212 Height h+t (mm) 242 Weight (kg) 2.5 UC 116 278 308 3.5 VC 136 212 242 3.2 M12 M M12 Toothed washer Hex nut 15 16 + 1 d Creepage distance h h h (t) d Mechnanical characteristics 15 5 Tightening Torque = 2.5 Nm VarplusCan TC, UC & VC d Case Code: XC & YC 1+5 M10 3+t h 3 + a (expansion) 1 16 + 1 d Creepage distance Clearance Expansion (a) 60 mm 34 mm max.12mm Mounting details (for M10/M12 mounting stud) h h 3 t 2 STUD type terminal In-built resistor type M12 Toothed washer Hex nut Torque Toothed washer Hex nut Terminal screw Terminal assembly Ht. (t) T = 10 Nm J12.5 DIN 6797 BM12 DIN 439 M10 43 mm Case code XC Diameter d (mm) 116 Height h (mm) 278 Height h+t (mm) 321 Weight (kg) 4.1 YC 136 278 321 5.3 Tightening Torque = 2.5 Nm 47 1 VarplusCan XC & YC 9 VarplusBox Low Voltage Capacitors 60Hz Techinical Particulars VarplusBox capacitors deliver reliable performance in the most severe application conditions, in Fixed & Automatic PFC systems, in networks with frequently switched loads and harmonic disturbances. Robustness • Double metallic protection. • Mechanically well suited for “stand-alone” installations. Safety • Its unique safety feature electrically disconnects the capacitors PE90135 safely at the end of their useful life. • The disconnectors are installed on each phase, which makes the capacitors very safe, in addition to the protective steel enclosure. Flexibility • These capacitors can be easily mounted inside panels or in a • • Unique foot print upto 20 kvar (VarplusBox HDuty Compact) Features • Metal box enclosure. • High power ratings up to 100 kvar. • Easy repair and maintenance. • Up to 70°C temperature. • High continious current withstand up to 2.5 x I . • Stand-alone PFC equipment. • Direct connection to a machine, in harsh environmental condiN VarplusBox tions. PE90135 PE90137 PE90164 HDuty Construction Steel sheet enclosure Voltage range 230 V - 830 V Power range (three-phase) 5 - 100 kvar Peak inrush current Up to 250 x IN Overvoltage 1.1 x UN As per IEC 60831- 1/2 400 V - 525 V Up to 350 x IN Overcurrent 1.8 x IN 2.5 x IN Mean life expectancy Up to 130,000 h Up to 160,000 h Safety Self-healing + pressure-sensitive disconnector + discharge device (50V/1min) Dielectric 10 Energy alloy with wave cut & slope metallization Double metallized paper Impregnation Non-PCB, Biodegradable sticky resin (dry) Non-PCB, oil Ambient temperature -25°C to max 55°C/Class D -25°C to 70°C Protection IP20 Mounting Upright, Horizontal Terminals Terminals designed for large cable termination and direct busbar mounting for banking Upright VarplusBox Hduty Low Voltage Capacitors Rated 50Hz Voltage 380V 2.3 4.5 6.8 7.5 9.4 11.3 13.6 18.1 18.8 22.6 37.6 45.1 400V 2.5 5 7.5 8.3 10.4 12.5 15.1 20.1 20.8 25 41.7 50 Rated 440V Voltage Rated 480V Voltage Rated Voltage 525V 380/400/415V 60Hz QN (kvar) IN(A) QN (kvar) 415V @400V 2.7 3.6 5.4 7.2 5.4 8.1 10.8 8.1 8.9 12.0 9.0 11.2 15.0 11.3 13.5 18.0 13.5 16.3 21.8 16.3 21.6 29.0 21.8 22.4 30.0 22.6 26.9 36.1 27.1 44.9 60.2 45.1 53.8 72.2 --- 50Hz 380V 2.7 400V 3 6 9 10 12.5 15 18 24 25 30 50 --- 60Hz IN(A) µF Case (X3) Code Reference Number 415V @400V 3.2 4.3 16.6 AB BLRBH025A030B40 6.5 8.7 33.1 AB BLRBH050A060B40 9.7 13.0 49.7 AB BLRBH075A090B40 10.8 14.4 55.0 AB BLRBH083A100B40 13.5 18.0 68.9 AB BLRBH104A125B40 16.1 21.7 82.9 AB BLRBH125A150B40 19.5 26.1 100.1 GB BLRBH151A181B40 25.9 34.8 133 GB BLRBH201A241B40 26.9 36.1 138 GB BLRBH208A250B40 32.3 43.3 166 GB BLRBH250A300B40 53.8 72.2 276 IB BLRBH417A500B40 --- --- 331 IB BLRBH500A000B40 µF Case QN (kvar) IN(A) QN (kvar) IN(A) (X3) Code 10 12.5 25 50 13.1 12 15 30 15.7 54.8 AB BLRBH100A120B44 19.7 68.5 AB BLRBH125A150B44 39.4 137 GB BLRBH250A300B44 --- 274 IB BLRBH500A000B44 µF Case Reference Number 50Hz 16.4 32.8 65.6 --- 60Hz Reference Number QN (kvar) IN(A) QN (kvar) IN(A) (X3) Code 8.3 8.8 10.4 12.5 10.0 10 10.6 12.5 15 12.0 38.2 AB BLRBH083A100B48 12.7 40.5 AB BLRBH088A106B48 15.0 47.9 AB BLRBH104A125B48 18.0 57.5 AB BLRBH125A150B48 15.6 17.1 19.3 20.8 21.6 22.7 25.8 28.8 31.5 33.9 41.7 51.6 56.6 61.9 18.8 18.7 20.5 23 25 25.9 27.2 31 34.6 37.8 40.7 50 61.9 67.9 22.5 71.8 GB BLRBH156A187B48 24.7 78.7 GB BLRBH171A205B48 27.9 88.8 GB BLRBH193A231B48 30.0 95.7 GB BLRBH208A250B48 31.2 99.4 GB BLRBH216A259B48 32.8 104 GB BLRBH227A272B48 37.2 119 GB BLRBH258A310B48 41.6 133 GB BLRBH288A346B48 45.5 145 GB BLRBH315A378B48 48.9 156 GB BLRBH339A407B48 60.2 192 IB BLRBH417A500B48 74.5 238 IB BLRBH516A619B48 81.7 261 IB BLRBH566A679B48 285 IB BLRBH619A000B48 Reference Number 50Hz 10.6 12.5 15.0 20.6 23.2 25.0 26.0 27.3 31.0 34.6 37.9 40.8 50.2 62.1 68.1 74.5 60Hz µF Case QN (kvar) IN(A) QN (kvar) IN(A) (X3) Code 10 12.5 16.6 20 25 40 50 11.0 12 15 19.9 24.1 30 48 60 13.2 38.5 AB BLRBH100A120B52 16.5 48.1 AB BLRBH125A150B52 21.9 63.9 GB BLRBH166A199B52 26.5 77.3 GB BLRBH201A241B52 33.0 96.2 GB BLRBH250A300B52 52.8 153.9 IB BLRBH400A480B52 66.0 192 IB BLRBH500A600B52 13.7 18.3 22.1 27.5 44.0 55.0 11 Rated 690V Voltage Rated 830V Voltage 12 50Hz 60Hz µF Case QN (kvar) IN(A) QN (kvar) IN(A) (X3) Code 15.1 12.6 18.1 15.1 33.6 GB BLRBH151A181B69 20 16.7 24 20.1 44.6 GB BLRBH200A240B69 50 41.8 60 50.2 111 JB BLRBH500A600B69 µF Case Reference Number QN (kvar) IN(A) QN (kvar) IN(A) (X3) Code 34.1 23.7 40.9 28.5 52.5 GB 50Hz 60Hz Reference Number BLRBH341A409B83 VarplusBox Energy Low Voltage Capacitors Rated 50Hz Voltage QN (kvar) 380V 7.5 9.4 11.3 13.5 15.1 18.8 22.6 37.6 45.1 Rated 440V Voltage Rated 480V Voltage Rated Voltage 525V 380/400/415V 60Hz 400V 8.3 10.4 12.5 15 16.7 20.8 25 41.7 50 IN(A) QN (kvar) 415V @400V 380V 8.9 12.0 11.2 15.0 11.3 13.5 18.0 13.5 9.0 16.1 21.7 16.2 18 24.1 18.1 22.4 30.0 22.6 26.9 36.1 27.1 44.9 60.2 45.1 53.8 72.2 54.2 50Hz 60Hz 400V 10 12.5 15 18 20 25 30 50 60 IN(A) µF Case (X3) Code Reference Number 415V @400V 10.8 14.4 55.0 DB BLRBE083A100B40 13.5 18.0 68.9 DB BLRBE104A125B40 16.1 21.7 82.9 GB BLRBE125A150B40 19.4 26.0 99.4 GB BLRBE150A180B40 21.5 28.9 111 GB BLRBE167A200B40 26.9 36.1 138 GB BLRBE208A250B40 32.3 43.3 166 GB BLRBE250A300B40 53.8 72.2 276 IB BLRBE417A500B40 64.6 86.6 331 IB BLRBE500A600B40 µF Case Reference Number QN (kvar) IN(A) QN (kvar) IN(A) (X3) Code 10 12.5 15 20 25 50 13.1 15.7 54.8 DB BLRBE100A120B44 19.7 68.5 DB BLRBE125A150B44 23.6 82.2 GB BLRBE150A180B44 31.5 110 GB BLRBE200A240B44 39.4 137 GB BLRBE250A300B44 65.6 12 15 18 24 30 60 78.7 274 IB BLRBE500A600B44 µF Case Reference Number QN (kvar) IN(A) QN (kvar) IN(A) (X3) Code 8.8 10.4 11.3 12.5 13.6 15.5 17 20.8 25.8 28.8 31.5 33.9 41.7 10.6 10.6 12.5 13.6 15 16.3 18.6 20.4 25 31 34.6 37.8 40.7 50 12.7 40.5 DB BLRBE088A106B48 15.0 47.9 DB BLRBE104A125B48 16.3 52.0 DB BLRBE113A136B48 18.0 57.5 FB BLRBE125A150B48 19.6 62.6 FB BLRBE136A163B48 22.4 71.4 GB BLRBE155A186B48 24.5 78.3 GB BLRBE170A204B48 30.0 95.7 GB BLRBE208A250B48 37.2 119 GB BLRBE258A310B48 41.6 133 GB BLRBE288A346B48 45.5 145 IB BLRBE315A378B48 48.9 156 IB BLRBE339A407B48 60.2 192 IB BLRBE417A500B48 µF Case Reference Number 50Hz 50Hz 16.4 19.7 26.2 32.8 12.5 13.6 15.0 16.4 18.6 20.4 25.0 31.0 34.6 37.9 40.8 50.2 60Hz 60Hz QN (kvar) IN(A) QN (kvar) IN(A) (X3) Code 10 12.5 15.4 20 25 50 11.0 12 15 18.5 24 30 60 13.2 38.5 DB BLRBE100A120B52 16.5 48.1 FB BLRBE125A150B52 20.3 59.3 FB BLRBE154A185B52 26.4 77.0 GB BLRBE200A240B52 33.0 96.2 GB BLRBE250A300B52 66.0 192 IB BLRBE500A600B52 13.7 16.9 22.0 27.5 55.0 13 VarplusBox Low Voltage Capacitors 60Hz Mechnanical characteristics Case Code: AB DE90158 D Terminal cover Creepage distance Clearance Phase to phase Phase to earth 30 mm 25 mm (min.) 19 mm (min.) Mounting details: mounting screw M6, 2 Nos. H Enclosure Case code AB W1 (mm) 114 W2 (mm) 97 W3 (mm) 76.5 H D Weight (mm) (mm) (kg) 229.5 225.5 3 W3 W2 W1 192 Rubber grommet for cable entry Enclosure H W3 W1 W2 14 DE90159 D Case Code: DB, EB, FB, GB & HB Creepage distance Clearance Phase to phase Phase to earth 30 mm 25 mm (min.) 19 mm (min.) Mounting details: mounting screw M6, 2 Nos. Case code DB EB FB GB HB W1 (mm) 263 263 309 309 309 W2 (mm) 243 243 289 289 289 W3 (mm) 213 213 259 259 259 H (mm) 355 260 355 355 455 D (mm) 97 97 97 153 153 Weight (kg) 4.8 3.6 5.4 7.5 8.0 VarplusBox Low Voltage Capacitors 60Hz Mechnanical characteristics Case Code: IB DE90160 D Rubber grommet for cable entry Creepage distance Enclosure H 30 mm Clearance Phase to phase 25 mm (min.) Phase to earth 19 mm (min.) Mounting details: mounting screw M6, 2 Nos. Case code IB W1 (mm) 309 W2 (mm) 289 W3 (mm) 259 H (mm) 497 D Weight (mm) (kg) 224 10.0 W3 W1 W2 Top To cover Al Busbar M 10x35 Bolt Bolt Case Code: LB & SB Capacitor units Capaci pacitoru W1 250 DE90161 D H 125 Unit 1 Unit 2 Unit 3 Unit 4 Creepage distance Clearance Phase to phase Phase to earth 30 mm 25 mm (min.) 19 mm (min.) Mounting details: mounting screw M6, 4 Nos. Case code LB SB W1 (mm) 795 545 W2 (mm) 630 390 W3 (mm) 670 430 H (mm) 455 455 D (mm) 315 315 Weight (kg) 45 32.4 W2 W3 Cable entry plate Earthing ng Bolt 7x14 Slots 4 Nos 15 VarplusBox Low Voltage Capacitors 60Hz Mechnanical characteristics Case Code: JB To cover Top Al Busbar M 10x35 Bolt Capaci pacitor units u Capacitor Creepage distance W1 DE90162 250 Phase to phase 25 mm (min.) Phase to earth 19 mm (min.) Mounting details: mounting screw M6, 2 Nos. H Unit 1 125 Unit 2 W2 W3 Cable entry plate W1 (mm) 455 W2 (mm) 290 W3 (mm) 330 H (mm) 455 D Weight (mm) (kg) 315 22.5 Case Code: KB & RB To cover Top M 10x35 Bolt Case code JB 7x14 Slots 4 Nos ng Bolt Earthing Al Busbar Capaci pacitor units u Capacitor W1 250 DE90163 D Creepage distance Clearance Phase to phase Phase to earth 30 mm 25 mm (min.) 19 mm (min.) Mounting details: mounting screw M6, 4 Nos. H 125 Unit 1 Unit 2 Unit 3 W2 W3 Cable entry plate 16 30 mm Clearance D ng Bolt Earthing 7x14 Slots 4 Nos Case code KB RB W1 (mm) 625 435 W2 (mm) 460 280 W3 (mm) 500 320 H (mm) 455 455 D (mm) 315 315 Weight (kg) 32 24.3 VarplusBox Low Voltage Capacitors 60Hz Mechnanical characteristics Case Code: OB To Top cover Al Busbar M 10x35 Bolt Capaci pacitor units u Capacitor W1 Creepage distance D 30 mm 250 DE90164 Clearance Phase to phase 25 mm (min.) Phase to earth 19 mm (min.) Mounting details: mounting screw M6, 2 Nos. Case code OB H Unit 1 125 Unit 2 W2 W3 Cable entry plate Capacitor units Capaci Creepage distance Clearance D 250 DE90 DE90165 0165 0165 W1 H 125 Unit 1 Unit 2 Unit 3 Unit 4 W2 W3 Cable entry plate W3 (mm) 470 H (mm) 625 D Weight (mm) (kg) 315 30 Case Code: QB Top To cover M 10x35 Bolt W2 (mm) 430 7x14 Slots 4 Nos g Bolt Earthing Al Busbar W1 (mm) 595 Earthing g Bolt 30 mm Phase to phase 25 mm (min.) Phase to earth 19 mm (min.) Mounting details: mounting screw M6, 2 Nos. Case code QB W1 (mm) 1080 W2 (mm) 920 W3 (mm) 960 H (mm) 625 D Weight (mm) (kg) 315 60 7x14 Slots 4 Nos 17 Harmonic Application Tables Low Voltage Capacitors 60Hz PE90154 PE90131 VarplusCan and VarplusBox Capacitors when used along with Detuned Reactors have to be selected with a rated voltage higher the voltage across the capacitor is higher than the network service voltage (Us). The recommended Rated voltage of the capacitor to be used in + voltage (Us) & relative impedance is given in the table below. Capacitor Rated Voltage (UN) Network Service Voltage (US) 60Hz PE90154 PE90134 Reactive Impedance (%) + 18 60Hz 400 690 400 480 600 6% 480 830 480 575 690 13% 480 480 These values ensure a safe operation in the most stringent operating conditions. Less conservative values may be adopted, but a case by case analysis is necessary. VarplusCan HDuty + Detuned Reactor + Contactor Low Voltage Capacitors 60Hz Combination Table PE90154 PE90131 Network 400V, 60Hz PE90158 + Effective QN Capacitor Ref. Power @ (kvar) 480V 5.7% fr = 210Hz D.R Ref BLRCH075A090B48 × 1 LVR05065B40 × 1 6% / 7% Filter 7% fr = 190Hz D.R Ref. Capacitor Duty Contactor Ref. Power Contactor Ref. LVR07065B40 × 1 LC1-DFK11M7 × 1 LC1D12 × 1 6.5 9 10 13.6 BLRCH113A136B48 × 1 LVR05100B40 × 1 LVR07100B40 × 1 LC1-DFK11M7 × 1 LC1D12 × 1 12.5 17.3 BLRCH144A173B48 × 1 LVR05125B40 × 1 LVR07125B40 × 1 LC1-DFK11M7 × 1 LC1D12 × 1 25 34.6 BLRCH288A346B48 × 1 LVR05250B40 × 1 LVR07250B40 × 1 LC1-DMK11M7 × 1 LC1D32 × 1 50 67.9 BLRCH288A346B48 × 2 LVR05500B40 × 1 LVR07500B40 × 1 LC1-DWK12M7 × 1 LC1D80 × 1 100 135.8 BLRCH288A346B48 × 4 LVR05X00B40 × 1 LVR07X00B40 × 1 --- Network 400V, 60Hz Capacitor Voltage 480V LC1D115×1 13% Filter Effective Power (kvar) QN @ 480V Capacitor Ref. 14% fr = 135Hz D.R Ref. Capacitor Duty Contactor Ref. Power Contactor Ref. 6.5 8 BLRCH067A080B48 × 1 LVR14065B40 × 1 LC1-DFK11M7 × 1 LC1D12 × 1 10 12.5 BLRCH104A125B48 × 1 LVR14010B40 × 1 LC1-DFK11M7 × 1 LC1D12 × 1 12.5 16.3 BLRCH136A163B48 × 1 LVR14125B40 × 1 LC1-DFK11M7 × 1 LC1D12 × 1 25 31 BLRCH258A310B48 × 1 LVR14250B40 × 1 LC1-DLK11M7 × 1 LC1D25 × 1 50 62.0 BLRCH258A310B48 × 2 LVR14500B40 × 1 LC1-DTK12M7 × 1 LC1D50 × 1 100 124.0 BLRCH258A310B48 × 4 LVR14X00B40 × 1 --- LC1D115 × 1 Network 400V, 60Hz Effective QN Capacitor Ref. Power @ (kvar) 525V Contactor LC1DPK Capacitor Voltage 480V Capacitor Voltage 525V 5.7% fr = 210Hz D.R Ref 6% / 7% Filter 7% fr = 190Hz D.R Ref. Capacitor Duty Contactor Ref. Power Contactor Ref. 6.5 10.6 BLRCH088A106B52 × 1 LVR05065B40 × 1 LVR07065B40 × 1 LC1-DFK11M7 × 1 LC1D12 × 1 10 16.2 BLRCH135A162B52 × 1 LVR05100B40 × 1 LVR07100B40 × 1 LC1-DFK11M7 × 1 LC1D12 × 1 12.5 20.6 BLRCH172A206B52 × 1 LVR05125B40 × 1 LVR07125B40 × 1 LC1-DFK11M7 × 1 LC1D12 × 1 25 41.3 BLRCH344A413B52 × 1 LVR05250B40 × 1 LVR07250B40 × 1 LC1-DMK11M7 × 1 LC1D32 × 1 50 82.6 BLRCH344A413B52 × 2 LVR05500B40 × 1 LVR07500B40 × 1 LC1-DWK12M7 × 1 LC1D80 × 1 100 165.2 BLRCH344A413B52 × 4 LVR05X00B40 × 1 LVR07X00B40 × 1 --- Network 400V, 60Hz Capacitor Voltage 525V LC1D115×1 13% Filter Effective Power (kvar) QN @ 525V Capacitor Ref. 14% fr = 135Hz D.R Ref. Capacitor Duty Contactor Ref. Power Contactor Ref. 6.5 9.6 BLRCH080A096B52 × 1 LVR14065B40 × 1 LC1-DFK11M7 × 1 LC1D12 × 1 10 14.8 BLRCH125A150B52 × 1 LVR14010B40 × 1 LC1-DFK11M7 × 1 LC1D12 × 1 12.5 18.5 BLRCH154A185B52 × 1 LVR14125B40 × 1 LC1-DFK11M7 × 1 LC1D12 × 1 25 37.1 BLRCH309A371B52 × 1 LVR14250B40 × 1 LC1-DLK11M7 × 1 LC1D25 × 1 50 74.2 BLRCH309A371B52 × 2 LVR14500B40 × 1 LC1-DTK12M7 × 1 LC1D50 × 1 100 148.4 BLRCH309A371B52 × 4 LVR14X00B40 × 1 --- LC1D115 × 1 Network 480V, 60Hz Effective QN Capacitor Ref. Power @ (kvar) 575V Capacitor Voltage 575V 5.7% fr = 210Hz D.R Ref 6% Filter Capacitor Duty Contactor Ref. Power Contactor Ref. 12.5 18 BLRCH150A180B57 × 1 LVR05125B48 × 1 25 35 BLRCH292A350B57 × 1 LVR05250B48 × 1 LC1-DLK11M7 × 1 50 70 BLRCH292A350B57 × 2 LVR05500B48 × 1 LC1-DTK12M7 × 1 LC1D50 × 1 100 140 BLRCH292A350B57 × 4 LVR05X00B48 × 1 --- Network 600V, 60Hz Effective QN Capacitor Ref. Power @ (kvar) 690V Capacitor Voltage 690V 5.7% fr = 210Hz D.R Ref LC1-DFK11M7 × 1 LC1D12 × 1 LC1D25 × 1 LC1D115×1 6% Filter Capacitor Duty Contactor Ref. Power Contactor Ref. 12.5 16.5 BLRCH138A165B69 × 1 LVR05125B60 × 1 25 33.1 BLRCH276A331B69 × 1 LVR05250B60 × 1 LC1-DFK11M7 × 1 LC1D12 × 1 LC1-DLK11M7 × 1 50 66.2 BLRCH276A331B69 × 2 LVR05500B60 × 1 LC1-DTK12M7 × 1 LC1D50 × 1 100 132.4 BLRCH276A331B69 × 4 LVR05X00B60 × 1 --- LC1D25 × 1 LC1D115×1 19 VarplusCan Energy + Detuned Reactor + Contactor Low Voltage Capacitors 60Hz Combination Table PE90154 PE90131 Network 400V, 60Hz PE90158 + Contactor LC1DPK 20 Capacitor Voltage 480V Effective QN Capacitor Ref. Power @ (kvar) 480V 5.7% fr = 210Hz D.R Ref 6% / 7% Filter 7% fr = 190Hz D.R Ref. Capacitor Duty Contactor Ref. Power Contactor Ref. 6.5 8.9 BLRCE075A090B48 × 1 LVR05065B40 × 1 LVR07065B40 × 1 LC1-DFK11M7 × 1 LC1D12 × 1 10 13.6 BLRCE113A136B48 × 1 LVR05100B40 × 1 LVR07100B40 × 1 LC1-DFK11M7 × 1 LC1D12 × 1 12.5 17.3 BLRCE144A173B48 × 1 LVR05125B40 × 1 LVR07125B40 × 1 LC1-DFK11M7 × 1 LC1D12 × 1 25 34.6 BLRCE144A173B48 × 2 LVR05250B40 × 1 LVR07250B40 × 1 LC1-DLK11M7 × 1 50 69.2 BLRCE144A173B48 × 8 LVR05500B40 × 1 LVR07500B40 × 1 LC1-DTK12M7 × 1 LC1D80 × 1 100 138.4 BLRCE144A173B48 × 8 LVR05X00B40 × 1 LVR07X00B40 × 1 --- Network 400V, 60Hz Capacitor Voltage 480V LC1D32 × 1 LC1D115×1 13% Filter Effective Power (kvar) QN @ 480V Capacitor Ref. 14% fr = 135Hz D.R Ref. Capacitor Duty Contactor Ref. Power Contactor Ref. 6.5 8 BLRCE067A080B48 × 1 LVR14065B40 × 1 LC1-DFK11M7 × 1 LC1D12 × 1 10 12.5 BLRCE104A125B48 × 1 LVR14010B40 × 1 LC1-DFK11M7 × 1 LC1D12 × 1 12.5 16.3 BLRCE136A163B48 × 1 LVR14125B40 × 1 LC1-DFK11M7 × 1 LC1D12 × 1 25 32.6 BLRCE136A163B48 × 2 LVR14250B40 × 1 LC1-DMK11M7 × 1 LC1D25 × 1 50 65.2 BLRCE136A163B48 × 4 LVR14500B40 × 1 LC1-DWK12M7 × 1 LC1D50 × 1 100 130.4 BLRCE136A163B48 × 8 LVR14X00B40 × 1 --- LC1D115 × 1 VarplusBox Hduty + Detuned Reactor + Contactor Low Voltage Capacitors 60Hz PE90154 PE90134 Combination Table PE90158 + Network 400V, 60Hz Effective Power (kvar) QN @ 480V Capacitor Ref. 25 34.6 50 100 Capacitor Voltage 480V 6% / 7% Filter 6% fr = 210Hz D.R Ref Capacitor Duty Contactor Ref. Power Contactor Ref. BLRBH288A346B48 × 1 or BLRBH144A173B48 × 1 LVR05250B40 × 1 LC1-DMK11M7 × 1 LC1D32 × 1 67.9 BLRBH566A679B48 × 1 or BLRBH192A230B48 × 3 LVR05500B40 × 1 LC1-DWK12M7 × 1 LC1D80 × 1 135.8 BLRBH566A679B48 × 2 or BLRBH192A230B48 × 6 LVR05X00B40 × 1 --- LC1D115×1 Network 400V, 60Hz Effective Power (kvar) QN @ 480V Capacitor Ref. 25 31 50 61.9 100 Capacitor Voltage 480V 13% Filter 13% fr = 135Hz D.R Ref. Capacitor Duty Contactor Ref. Power Contactor Ref. BLRBH258A310B48 × 1 or BLRBH136A163B48 × 2 LVR14250B40 × 1 LC1-DLK11M7 × 1 LC1D25 × 1 BLRBH516A619B48 × 1 or BLRBH172A206B48 × 3 LVR14500B40 × 1 LC1-DTK12M7 × 1 LC1D50 × 1 123.8 BLRBH516A619B48 × 2 or BLRBH172A206B48 × 6 LVR14X00B40 × 1 --- LC1D115 × 1 Network 480V, 60Hz Capacitor Voltage 575V Effective QN Capacitor Ref. Power @ (kvar) 575V 6% Filter 6% fr = 210Hz D.R Ref Capacitor Duty Contactor Ref. Power Contactor Ref. LC1D25 × 1 25 36 BLRBH300A360B57 × 1 or BLRBH150A180B57 × 2 LVR05250B48 × 1 LC1-DLK11M7 × 1 50 72 BLRBH300A360B57 × 2 or BLRBH150A180B57 × 4 LVR05500B48 × 1 LC1-DTK12M7 × 1 LC1D50 × 1 100 144 BLRBH300A360B57 × 4 or BLRBH150A180B57 × 8 LVR05X00B48 × 1 --- Contactor LC1DPK Network 600V, 60Hz Capacitor Voltage 690V LC1D115×1 6% Filter Effective QN Capacitor Ref. Power @ (kvar) 690V 5.7% fr = 210Hz D.R Ref Capacitor Duty Contactor Ref. Power Contactor Ref. 12.5 16.5 BLRBH138A165B69 × 1 LVR05125B60 × 1 LC1-DFK11M7 × 1 LC1D12 × 1 25 33.1 BLRBH276A331B69 × 1 or BLRBH138A165B69 × 2 LVR05250B60 × 1 LC1-DLK11M7 × 1 50 66.2 BLRBH276A331B69 × 2 or BLRBH138A165B69 × 4 LVR05500B60 × 1 LC1-DTK12M7 × 1 LC1D50 × 1 100 132.4 BLRBH276A331B69 × 4 or BLRBH138A165B69 × 8 LVR05X00B60 × 1 --- LC1D25 × 1 LC1D115×1 Note:Reference Numbers in Green font are VarplusBox HDuty Compact Dimension 21 VarplusBox Energy + Detuned Reactor + Contactor Low Voltage Capacitors 60Hz PE90154 PE90134 Combination Table PE90158 + Contactor LC1DPK 22 Network 400V, 60Hz Capacitor Voltage 480V Effective QN Capacitor Ref. Power @ (kvar) 480V 5.7% fr = 210Hz D.R Ref 6% / 7% Filter Capacitor Duty Contactor Ref. Power Contactor Ref. 25 34.6 BLRBE288A346B48 × 1 LVR05250B40 × 1 LC1-DMK11M7 × 1 LC1D32 × 1 50 69.2 BLRBE288A346B48 × 2 LVR05500B40 × 1 LC1-DWK12M7 × 1 LC1D80 × 1 100 138.4 BLRBE288A346B48 × 4 LVR05X00B40 × 1 none Network 400V, 60Hz Effective Power (kvar) QN @ 480V Capacitor Voltage 480V Capacitor Ref. 14% fr = 135Hz D.R Ref. LC1D115×1 13% Filter Capacitor Duty Contactor Ref. Power Contactor Ref. 25 31 BLRBE258A310B48 × 1 LVR14250B40 × 1 LC1-DLK11M7 × 1 LC1D25 × 1 50 62 BLRBE258A310B48 × 2 LVR14500B40 × 1 LC1-DTK12M7 × 1 LC1D50 × 1 100 124 BLRBE258A310B48 × 4 LVR14X00B40 × 1 none LC1D115 × 1 關 於 施 耐 德 電 機 全球能源管理專家施耐德電機為100多個國家提供整體解決方案,以世界領先地位涵跨多個市場行業:市場能源與基礎設施、工業及機械 製造、非住宅樓宇、資料中心與網路及住宅。致力於為客戶提供安全、可靠、高效能、高產能及環保的能源,施耐德電機擁有130,000+ 名員工,2011年的銷售額為224億歐元,積極致力於幫助個人和組織善盡其效•盡享其能。 www.schneider-electric.com About Schneider Electric As a global specialist in energy management with operations in more than 100 countries, Schneider Electric offers integrated solutions across multiple market segments, including leadership positions in Utilities & Infrastructures, Industries & Machine Manufacturers, Non-residential Buildings, Data Centres & Networks and in Residential. Focused on making energy safe, reliable, efficient, productive and green, the Group’s 130,000 plus employees achieved sales of 22.4 billion euros in 2011, through an active commitment to help individuals and organizations make the most of their energy. TWVARPLUS13CH Schneider Electric - All rights reserved / 施耐德電機-版權所有 www.schneider-electric.com 施耐德電機股份有限公司 台北總公司 林口服務事業部暨物流處理中心 台中機械自動化中心 高雄辦事處 台北市114內湖區基湖路37號2樓 桃園縣龜山鄉工四工業區頂湖路9號1樓 台中市公益路二段51號9樓B1室 高雄市前鎮區中山二路260號21樓A2 電話:02-8751-6388 電話:03-396-0633 電話: 04-2319-3328 電話:07-537-6798 傳真:02-8751-6398 傳真:03-318-4905 傳真: 04-2329-6389 傳真:07-537-6799 www.schneider-electric.com.tw 客戶服務專線:0800-886-399 As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. 由於標準與材料因時變更的可能性,如需確認型錄中產品之規格與圖像,請與施耐德電機相關部門確認。