Transcript
P8.1.7
RECESSED DOWNLIGHT 1-3/4” REGRESSED PINHOLE APERTURE
PRODUCT DESCRIPTION Recessed PAR20/PAR16 downlight luminaire with 1¾” square regressed pinhole aperture. Fixture has 50° visual cutoff to lamp and lamp image. Sealed Air-Loc housing eliminates leak-paths to ensure maximum energy savings and controls plenum sound transmission. IC rated housing for use in direct contact with insulation.
PRODUCT SPECIFICATIONS Reflector .040” aluminum parabolic reflector in black Alzak finish shields housing interior. Trims Style Die cast Self Flanged and Flush Mount trims utilize precision wound double torsion springs for tight, secure fit to ceiling • Flush mount trim creates a truly trimless aperture • For flush mount installations in drywall ceilings use the FMASQ4 flush mount adapter • For flush mount installations in wood, stone, or tile ceilings the FMASQ4-SC*** must be used (specify ceiling thickness and adapter finish).
IC Rated, 50W PAR20 or 45W PAR16 IC13SQ, 4307SQ TRIM Project: Fixture Type: Location: Contact/Phone:
Socket Medium base porcelain socket with nickel plated copper screw shell. Lamp One 50W PAR20 or 45W PAR16. Codes/Labels UL and cUL listed for direct contact with insulation, through branch wiring, damp locations •Meets energy code Air Leakage requirements per ASTM E283 • Product thermally protected • Union made. Proprietary Bar Hanger System Patent pending Pro-VI™, telescoping bar hanger system with locking set screws, permits quick placement of housing within 24” O.C. joists or suspended ceilings • Robust bar eliminates flexing regardless of fixture position • Integral T-bar notch with locking tabs secures housing to suspended ceiling grid • Captive bugle-headed ring shank nail for quick one-step installation • Bar Hanger foot aligns to bottom of construction joist and breaks away for use in suspended ceilings. Junction Box Rated for 4 No. 12 AWG 90° C through branch circuit conductors and includes (6) ½”, (1) ¾”, and (4) Nonmetallic sheathed cable knock-outs • Push-In electrical connectors for field connections. Housing/Mounting Frame Steel plaster frame and aluminum housing painted black for visually dark interior • V-Notch in plaster frame aids fixture alignment during installation • Patent Pending Tru-Line™ Adjustment Mechanism featuring +/- ½” translation and +/- 45° aperture rotation aids fixture alignment after installation, prior to drywall.
DIMENSIONS 13 3/4" Will expand to 24 3/8" (Reduces to 10 3/4" with breakaway feature)
15 1/8" 19 5/8"
Ceiling Thickness 1/2” – 7/8” ceiling standard • For thicker ceilings, order CTA4SQ-125 (7/8”-1 1/4”), CTA4SQ-163 (1 1/4”1 5/8”) or CTA4SQ-200 (1 5/8” – 2”) • CTA4SQ not required for wood, stone, or tile flush mount applications.
8 15/16"
1 3/4" A
4 1/8” CEILING CUTOUT
(REFER TO INSTRUCTION SHEET FOR FLUSH MOUNT CEILING CUTOUT)
REV-8/13
Self Flanged Flush Mount
A
4 1/2” 3 5/8”
P8.1.7
RECESSED DOWNLIGHT 1-3/4” REGRESSED PINHOLE APERTURE IC Rated, 50W PAR20 or 45W PAR16 IC13SQ, 4307SQ TRIM 1 3/4” Regressed Downlight Pinhole
Housings Catalog #
Description
IC13SQ
Line Voltage Recessed, 120V
Self Flanged Flush Mount1
Description
4307SQ-WH 4307SQ-WH-FM White Trim 4307SQ-BL 4307SQ-BL-FM Black Trim Flush Mount trims must be used with Flush Mount Adapter, ordered separately. 1
Product specifications subject to change without notice.
Flush Mount Adapters FMASQ4 FMASQ4-SC100-WH FMASQ4-SC100-BL FMASQ4-SC138-WH FMASQ4-SC138-BL FMASQ4-SC175-WH FMASQ4-SC175-BL
Drywall Ceiling Adapter Wood, Stone, Tile, 1/2”-1” Thick Ceiling, Adapter, White Wood, Stone, Tile, 1/2”-1” Thick Ceiling, Adapter, Black Wood, Stone, Tile, 1”-1 3/8” Thick Ceiling, Adapter, White Wood, Stone, Tile, 1”-1 3/8” Thick Ceiling, Adapter, Black Wood, Stone, Tile, 1 3/8”-1 3/4” Thick Ceiling, Adapter, White Wood, Stone, Tile, 1 3/8”-1 3/4” Thick Ceiling, Adapter, Black
Optical Accessories Cat. # T741 T742 T743 T744 T745 T746 T7401 T7403 T7404
Description
Med. Pink Color Filter Warm Red Color Filter Daylight Blue Color Filter Med. Blue Color Filter Med. Amber Color Filter Med. Green Color Filter Red Dichroic Lens Med. Green Dichroic Lens Med. Blue Dichroic Lens
Misc. Accessories Cat. # T7405 T7406 T7411 T7416 T7420 T7422 T7477 T7478 T7459BL
Description
Yellow Dichroic Lens Magenta Dichroic Lens Blue Green Dichroic Lens Daylight Blue Correction Lens Diffuse Spread Lens UV Filter Lens Prismatic Lens Linear Spread Lens Hexcell Louver
CTA4SQ-125 CTA4SQ-163 CTA4SQ-200
1 1/4” Thick Ceiling Adapter 1 5/8” Thick Ceiling Adapter 2” Thick Ceiling Adapter
To order, specify catalog number.
1300 S. Wolf Road • Des Plaines, IL 60018 • Phone (847) 827-9880 • Fax (847) 827-2925 220 Chrysler Drive • Brampton, Ontario • Canada L6S 6B6 • Phone (905) 792-7335 • Fax (905) 792-0064 Visit us at www.junolightinggroup.com Printed in U.S.A. ©2013 Juno Lighting, LLC.
P8.1.7 PHOTOMETRIC REPORT Catalog Number: IC13SQ (4307SQ-WH) Test Number: PT02100304 Total Luminaire Efficiency: 60.4% Luminaire Spacing Criteria: 0.32 Luminaire: 1 3/4” square regressed pinhole trim. Clear glass lens. Lamps: One 45PAR16/SP10, rated at 420 total lumens.
90 85
250
75
500
65
750 1000
55
1250 45
1500 1750
35
2000 0
5
15
25
90 85 75
500
65
750 1000
55
1250 45
1500 1750
35
2000 0
5
15
25
Distance to Illuminated Footcandles Plane (Feet) Beam Center
Candlepower Distribution (Candelas) Angle Candela Lumens 0° 2221 5° 1370 131 15° 404 114 25° 107 49 35° 5 3 45° 3 2 55° 0 0 65° 0 0 75° 0 0 85° 0 0
6’ 7’ 8’ 9’ 10’ 11’ 12’ 13’ 14’ 15’
Footcandles Beam Edge
Beam Diameter
55.7 27.3 1.4’ 40.9 20.0 1.6’ 31.3 15.3 1.9’ 24.8 12.1 2.1’ 20.0 9.8 2.3’ 16.6 8.1 2.6’ 13.9 6.8 2.8’ 11.9 5.8 3.0’ 10.2 5.0 3.3’ 8.9 4.4 3.5’
Luminance Data Ang in Deg Footlamberts 45 1204 55 0 65 0 75 0 85 0
Candlepower Distribution (Candelas) Angle Candela Lumens 0° 2005 5° 1543 147 15° 238 68 25° 65 30 35° 7 5 45° 6 4 55° 0 0 65° 0 0 75° 0 0 85° 0 0
PHOTOMETRIC REPORT Catalog Number: IC13SQ (4307SQ-WH) Test Number: PT02100307 Total Luminaire Efficiency: 54.5% Luminaire Spacing Criteria: 0.26 Luminaire: 1 3/4” square regressed pinhole trim. Clear glass lens. Lamps: One 50PAR20/HAL/NSP10, rated at 550 total lumens.
250
Initial Footcandles
Candela/M2 4124 0 0 0 0
Zonal Lumen Summary Zone Lumens %Lamp %Fixture 0-30° 245 58.3 96.4 0-40° 249 59.4 98.2 0-60° 254 60.4 100.0 0-90° 254 60.4 100.0 90-180° 0 0.0 0.0 0-180° 254 60.4 100.0 Initial Footcandles Distance to Illuminated Footcandles Plane (Feet) Beam Center
6’ 7’ 8’ 9’ 10’ 11’ 12’ 13’ 14’ 15’
Footcandles Beam Edge
Beam Diameter
61.7 30.4 1.3’ 45.3 22.3 1.5’ 34.7 17.1 1.7’ 27.4 13.5 1.9’ 22.2 10.9 2.1’ 18.4 9.0 2.3’ 15.4 7.6 2.5’ 13.1 6.5 2.7’ 11.3 5.6 2.9’ 9.9 4.9 3.1’
Luminance Data Ang in Deg Footlamberts 45 620 55 0 65 0 75 0 85 0
Candela/M2 2126 0 0 0 0
Zonal Lumen Summary Zone Lumens %Lamp %Fixture 0-30° 295 53.6 98.3 0-40° 297 54.1 99.2 0-60° 300 54.5 100.0 0-90° 300 54.5 100.0 90-180° 0 0.0 0.0 0-180° 300 54.5 100.0
AVERAGE INITIAL FOOTCANDLES Reflectances: 80% Ceiling, 50% Walls, 20% Floors Luminaire Room Cavity Ratio Spacing RCR1 RCR3 4’ x 4’ 18 17 5’ x 5’ 12 11 6’ x 6’ 8 7 7’ x 7’ 7 6 8’ x 8’ 5 5 9’ x 9’ 4 4 10’ x 10’ 3 3 12’ x 12’ 2 2
RCR5 16 10 7 6 4 3 3 2
COEFFICIENTS OF UTILIZATION – % (Zonal Cavity Method) Effective Floor Reflectance 20% PCC 80 70 50 30 10 PW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 72 72 72 72 70 70 70 70 67 67 67 64 64 64 62 62 62 1 70 69 68 67 68 67 67 66 65 64 64 63 62 62 61 60 60 2 68 66 64 63 67 65 64 62 63 62 61 61 61 60 60 59 59 3 66 64 62 60 65 63 61 60 61 60 59 60 59 58 59 58 57 4 65 62 60 58 64 61 59 58 60 58 57 59 58 57 58 57 56 5 63 60 58 56 62 60 58 56 59 57 56 58 56 55 57 56 55 6 62 59 56 55 61 58 56 55 57 56 54 57 55 54 56 55 54 7 60 57 55 54 60 57 55 53 56 54 53 56 54 53 55 54 53 8 59 56 54 52 59 56 54 52 55 53 52 55 53 52 54 53 52 9 58 55 53 51 58 55 53 51 54 52 51 54 52 51 53 52 51 10 57 54 52 50 57 54 52 50 53 51 50 53 51 50 53 51 50 AVERAGE INITIAL FOOTCANDLES Reflectances: 80% Ceiling, 50% Walls, 20% Floors Luminaire Room Cavity Ratio Spacing RCR1 RCR3 4’ x 4’ 21 20 5’ x 5’ 14 13 6’ x 6’ 9 9 7’ x 7’ 8 7 8’ x 8’ 6 6 9’ x 9’ 5 4 10’ x 10’ 3 3 12’ x 12’ 2 2
0 0 60 59 58 56 55 54 53 52 51 50 50
RCR5 18 12 8 7 5 4 3 2
COEFFICIENTS OF UTILIZATION – % (Zonal Cavity Method) Effective Floor Reflectance 20% PCC 80 70 50 30 10 PW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 65 65 65 65 63 63 63 63 61 61 61 58 58 58 56 56 56 1 63 62 61 60 62 61 60 59 58 58 57 56 56 55 55 54 54 2 61 59 58 56 60 58 57 56 57 55 54 55 54 53 54 53 52 3 59 57 55 54 58 56 54 53 55 53 52 54 52 51 52 52 51 4 58 55 53 51 57 54 52 51 53 52 50 52 51 50 51 50 49 5 56 53 51 49 55 53 51 49 52 50 49 51 50 48 50 49 48 6 55 51 49 48 54 51 49 48 50 49 47 50 48 47 49 48 47 7 53 50 48 46 53 50 48 46 49 47 46 49 47 46 48 47 46 8 52 49 47 45 51 48 46 45 48 46 45 47 46 45 47 46 45 9 51 47 45 44 50 47 45 44 47 45 44 46 45 44 46 45 44 10 50 46 44 43 49 46 44 43 46 44 43 45 44 43 45 44 43
1300 S. Wolf Road • Des Plaines, IL 60018 • Phone (847) 827-9880 • Fax (847) 827-2925 220 Chrysler Drive • Brampton, Ontario • Canada L6S 6B6 • Phone (905) 792-7335 • Fax (905) 792-0064 Visit us at www.junolightinggroup.com Printed in U.S.A. ©2013 Juno Lighting, LLC.
0 0 55 53 51 50 49 47 46 45 44 43 42