Preview only show first 10 pages with watermark. For full document please download

Recessed Laboratory Units

   EMBED


Share

Transcript

Recessed Laboratory Units FF GBF1671 Recessed Emergency Shower, Recess Mounted Shower Head Application: Recessed emergency shower with ceiling mounted recessed shower head. Recessed shower conserves valuable floor space, while eliminating the clutter and obstruction created by conventional shower equipment. Unit can be installed in either a corridor or a lab room, close to where accidents might occur. ADA Compliance: When installed at recommended mounting heights, unit complies with ADA requirements for accessibility by handicapped persons. Shower Head: 10” diameter stainless steel with 20 GPM flow control and flange for flush mounting in ceiling. Valve: 1" IPS brass stay-open ball valve with stainless steel “panic bar.” Pulling bar down activates shower; shower remains in operation until bar is returned to original closed position. Furnished with stainless steel access panel and 1" IPS unions for valve. Supply: 1" NPT female inlet. Sign: ANSI-compliant identification sign. U.S. Patent 5,768,721 NOTE: ANSI Z358.1-2014 specifies that shower heads be installed no more than 96" above the finished floor. This unit should therefore not be installed in ceilings over 8 feet. For higher ceiling heights, we recommend either the GBF1670 or GBF1672 showers. Available Options FF AP250-065 Modesty curtain for wall mounting. FF AP280-235 Electric strobe light and alarm horn unit for recess mounting in finished wall. Light illuminates and horn sounds when shower is activated. Includes additional leads for remote monitoring. FF G3800LF Thermostatic mixing valve precisely blends hot and cold water to deliver warm (tepid) water as required by ANSI Z358.1-2014. Refer to “Tempering Valves” section for complete technical and product selection information. Guardian Equipment 1140 N North Branch St Chicago, IL 60642 312 447 8100 TELEPHONE 312 447 8101 FACSIMILE gesafety.com Note: Shown with optional AP280-235 electric light and alarm horn unit (sold separately). Listed 8116. Units have been tested to and comply with ANSI Z358.1-2014 and the Uniform Plumbing Code. Recessed Laboratory Units FF GBF1671 Recessed Emergency Shower, Recess Mounted Shower Head NOTES: 1. A MINIMUM OF 4 1/8" IS REQUIRED FROM FINISHED WALL SURFACE TO REAR OF WALL CAVITY TO ACCOMODATE UNIT. 2. U.S. PATENT NO. 5,768,721. 3. PROVIDE 7 1/4" X 14 1/2" CUTOUT IN WALL FOR HOUSING INSTALLATION. PIPE SUPPORT BY OTHERS PIPING AND FITTINGS SHOWN IN DOTTED SUPPLIED BY OTHERS 36" (915mm) RECOMMENDED 82"-96" (2083-2438mm) TO FINISHED FLOOR 10" (254mm) MOUNTING HOLE 11 3/4" (299mm) SEE NOTE STAINLESS STEEL FLANGED SHOWER HEAD WITH 20 GPM FLOW CONTROL 3 5/16" (84mm) TO PIPE CETERLINE HEAVY DUTY STAINLESS STEEL "PANIC BAR" WITH BLACK VINYL FOAM GRIP (PULL TO ACTIVATE SHOWER) 9" (229mm) 8" (203mm) REMOVABLE ACCESS PANEL 7 1/4" (184mm) STAINLESS STEEL CABINET 2 3/4" (60mm) FROM FINISHED WALL SURFACE TO CENTERLINE OF PIPING 1 7/16" (37mm) 1 3/4" (45mm) 1" NPT FEMALE UNION OUTLET 2 1/2" (64mm) 10 1/4" (260mm) 14 3/8" (365mm) 16 1/4" (413mm) 48"MAX. (1219mm) TO FINISHED FLOOR 90° SWING 1" IPS BRASS STAYOPEN BALL VALVE 1" NPT FEMALE UNION INLET THIS SPACE FOR ARCHITECT/ENGINEER APPROVAL Due to continuing product improvement, the information contained in this document is subject to change without notice. All dimensions are ± 1/4" (6mm). rev. 0517 Guardian Equipment 1140 N North Branch St Chicago, IL 60642 312 447 8100 TELEPHONE 312 447 8101 FACSIMILE gesafety.com Sign Included Emergency Shower Keep Area Clear Test All Emergency Equipment Weekly Listed 8116. Units have been tested to and comply with ANSI Z358.1-2014 and the Uniform Plumbing Code.