Preview only show first 10 pages with watermark. For full document please download

Redin45

   EMBED


Share

Transcript

Features • Universal AC Input (85-264VAC) • Long 7 Year Warranty • Protections: SCP, OVP, OCP, OLP, OTP • 100% Full Load burn-in test • DC OK Indicator LED (optional with relay output) • cooling by free air convection, 5000m operation • UL, CSA & CE certified with CB Report Description This DIN-rail mounted power supply uses high reliability components to give a long, trouble-free life. The power supply can be end mounted to save space or side mounted for use in low-profile cabinets. Relay contacts simplifyand the units can be deliver 60W start-up power. The REDIN series is fully certified for industrial use and carries a 7-year warranty. Selection Guide AC/DC Converter REDIN45 45 Watt DIN-Rail Power Supply YEA R 7 wa rranty Part Input Output Output Rated Efficiency Number Voltage Range Voltage Trimming Voltage Current typ. (VAC) (VDC) (VDC) (mA) (%) REDIN45-12 85-264 12 12-15 3.75 84 REDIN45-24 85-264 24 24-28 1.875 86 * add suffix /NR for versions without relay Specifications (measured at TA= 25°C, 230VAC, rated load) BASIC CHARACTERISTICS Parameter Condition Min. Input Voltage Range all operating conditions 85VAC 120VDC max. Input Voltage max. 1 second Output Voltage Adjustment (Factory Setting) (1) Typ. Max. 264VAC 250VDC 300VAC 375VDC 12Vout 24Vout 12-15VDC (12V±5%) 24-28VDC (24V±5%) Input Current full load, 115VAC full load, 230VAC 1.35A 0.75A Inrush Current cold start at 25°C, 115VAC cold start at 25°C, 230VAC 40A 60A standard (with Relay) /NR option (no Relay) <1000mW <500mW No Load Power Consumption Leakage Current 240VAC <1.0mA Start Up time cold start, 230VAC 500ms Rise time cold start, 230VAC 20ms Hold-up time full load, 115VAC full load, 230VAC 20ms 50ms Input Frequency 47kHz Efficiency CB-Report UL-60950-1 Certified UL-508 Certified IEC-60950-1 Certified EN-60715 Compliant EN-50022 Compliant CSA C22.2 No. 60950-1-07 Certified 63kHz see Selection Guide Output Ripple and Noise (2) Over Load Notes: Note1: Note2: 1000ms E314885 12Vout 24Vout all operating conditions 60mVp-p 75mVp-p 140% for 5 seconds max. For more details refer to Vadj. Derating Graph Ripple and Noise are measured at 20MHz bandwidth by using a 12” twisted pair-wire terminated with 0.1µF & 47µF parallel capacitor. continued on next page Refer to Applications Notes www.recom-international.com REV.: 0/2015 PA-1 REDIN45 AC/DC Converter Series Specifications (measured at TA= 25°C, 230VAC, rated load) Efficiency vs. Load REDIN45-24 Efficiency (%) Efficiency (%) 90 80 70 60 50 40 30 20 10 0 REDIN45-12 85VAC 115VAC 230VAC 264VAC 0 1 3 2 3.75 90 80 70 60 50 40 30 20 10 0 85VAC 115VAC 230VAC 264VAC 0 0.5 Load (A) 1.5 1 1.875 Load (A) 100 90 80 Load (%) 70 60 100 80 45W max. 80 12VDC 70 Vadj. 15 (28) 60 Output Voltage (V) 50 40 30 40 30 REGULATION 20 20 Parameter 10 Condition Line Regulation 0 -20 Load Regulation Transient Response 24VDC 90 12VDC 12 (24) 50 100 24VDC Load (%) Output Current (%) Vadj. Derating -10 10 30 50 0 -20 70 Value 10 ±0.1 typ. / ±1% max. -10 Ambient Temperature (°C) 12Vout (step load change: 1.875A - 3.75A) (3) 24Vout (step load change: 0.937A - 1.875A) Derating: 3W / 1000m or 5°C / 1000m Notes: Note3: Parameter Condition Short Circuit Protection (SCP) 3000 Ta= 50°C Hiccup Over Voltage Protection (OVP) 12Vout 24Vout 2000 Over Current Protection (OCP) Over Temperature Protection (OTP) Isolation Resistance Power OK LED PA-2 20 40 50 70 max. ±0.1 typ. / ±1% Ambient Temperature (°C) ±5% typ. ±5% typ. 100Hz & 1kHz 50% duty 0.5A / µs Derating: 1.5W / 1000m or 5°C / 1000m Ta= 55°C 5000 4000 PROTECTION Isolation Voltage 30 35°Cloading 3300µF. Other specs with resistive load only. Transient Response Ta= + E-CAP Altitude (m) 5000 Altitude (m) Dwell Time Slew Rate 10 detect on inside ambient I/P to O/P 100 I/P to FG Load (%) O/P to FG 500VDC, 70% RH, I/P to O/P; I/P to FG; O/P to FG 60 80 Relay Contacts LED/Relay 4000 Value auto-recovery fault condition Ta=after 40°C 18VDC max., shut-down latch-off o/p voltage, re-power on to recover 35VDC max., shut-down latch-off o/p voltage, re-power on to recover 2000 150% typ., auto-recovery after fault condition 3000 105°C±5%, shut-down latch-off o/p voltage, re-power on to recover 20 40 60 Load (%) 3.75kVAC / 1 minute 80 100 1.88kVAC / 1 minute 0.5kVAC / 1 minute 100MW min. 1A, 30VDC / 120VAC ON if Vout = 11-16V (12V) / 22-30V (24V) REV.: 0/2015 www.recom-international.com REDIN45 AC/DC Converter Series Specifications (measured at TA= 25°C, 230VAC, rated load) ENVIRONMENTAL Parameter Condition Value Operating Temperature Range with derating -20°C to +70°C (see graph) Storage Temperature Range -30°C to +85°C Operating Humidity non-condensing 20% - 90%RH Storage Humidity 10% - 90% RH Vibration 10-500Hz 2G, 60min. Shock 3 times each axis 10G / 11ms, along X, Y and Z axis Altitude see derating graph 5000m MTBF (+25°C) MIL-HDBK-217F, 115VAC, 60Hz, 75% load 200 x 10³ hours Design Lifetime (+40°C) 87.6 x 10³ hours Derating Graph Vin ≤ 100VAC Vin ≤100VAC > 100VAC VinVin>100VAC 100 90 80 24VDC 12VDC Load (%) Vin ≤100VAC12VDC 70 100 60 -10 10 30 50 70 Temperature (°C) 20 24VDC 90 50 80 40 70 30 60 20 50 10 40 0 30-20 12VDC -10 10 30 50 70 50 70 Temperature (°C) 10 10 30 Temperature (°C) 5000 50 REDIN60-24 (45W) 50°C (45W) 4000 2000 3000 60 80 20 40 60 www.recom-international.com (45W) 4000 2000 3000 40 60 80 100 80 100 Load (%) 20 Load (%) (45W) 40°C 20 100 40°C 35°C 5000 3000 2000 80 35°C 4000 100 Load (%) 2000 30 5000 50°C 35°C 40 10 Temperature (°C) 4000 20 -10 35°C REDIN60-12 5000 3000 0 -20 70 Altitude (m) Altitude (m) -10 Typical Characteristics Altitude (m) Altitude (m) Vin >100VAC12VDC 70 100 60 20 10 0 -20 24VDC 90 Load (%) Load (%) Load (%) 80 90 50 80 40 70 30 60 20 50 10 40 0 30-20 100 24VDC 40 60 Load (%) REV.: 0/2015 PA-3 REDIN45 AC/DC Converter Series Specifications (measured at TA= 25°C, 230VAC, rated load) SAFETY AND CERTIFICATIONS Certificate Type Report / File Number Standard UL General Safety E224736 UL-60950-1, 2nd Edition UL-508 UL-1310 C22.2 No. 60950-1-07, 2nd Edition IEC/EN General Safety E224736 IEC/EN-60950-1, 2nd Edition Chinese Safety Standard E224736 GB 4943.1-2011 Certificate Type (Environmental) Condition Standard / Criterion CSA EMI Standard EN-55011, Class B EN-55022, Class B EN55024 FCC, Class B ESD Radiated Immunity Fast Transient Surge Conducted Immunity Power frequency magnetic field immunity test Noise Immunity EN-61000-4-2, Criteria A EN-61000-4-3, Criteria A EN-61000-4-4, Criteria A EN-61000-4-5, Criteria A EN-61000-4-6, Criteria A EN-61000-4-8, Criteria A EN-61000-4-11, Criteria A EN-61000-4-11, Criteria B EN-61000-4-11, Criteria B EN-61000-3-2 EN-61000-3-3 ±8kV Contact & Air Discharge 10V/m, 80-3000MHz, 80% AM at 1kHz Level 2 ±2kV / L-N, ±4kV / L, N-FG 10Vrms, 0.15-80MHz, 80% AM at 1kHz Harmonic Immunity Voltage Flicker 40% reduction, 200ms 70% reduction, 500ms 90% reduction, 5s not applicable input below 75W DIMENSIONS and PHYSICAL CHARACTERISTICS Parameter Type Value Case Material UL94V-0 plastic Dimensions (WxHxD) 92.0 x 45.1 x 101.2m Weight 332g Packaging Dimensions (LxWxH) Cardboard Box Packaging Quantity 310 x 252 x 285mm Carton 30pcs Mechanical Dimensions 92.0 101.2 Front Side 45.1 continued on next page PA-4 REV.: 0/2015 DIN-RAIL mounting bracket www.recom-international.com Front Side REDIN45 AC/DC Converter Series 45.1 Specifications (measured at TA= 25°C, 230VAC, rated load) Mechanical Dimensions DIN-RAIL mounting bracket (75mm) included 7.5±0.2 75±0.3 6.3±0.2 35±0.1 25.0 18±0.2 1±0.05 25.0 END MOUNTING SIDE MOUNTING Front Side End Latch Release Side Latch Release Tolerance: ±0.5mm Mounting Instruction Releasing Mounting 1 Front Side Front Side 2 2 „Click“ 1 continued on next page www.recom-international.com REV.: 0/2015 PA-5 REDIN45 AC/DC Converter Series Specifications (measured at TA= 25°C, 230VAC, rated load) Mounting Multiple Power Supplies 0mm 0mm no spacers between supplies required Functional Diagram L N T2.5A Input Filter Power Stage E +V Output Filter -V DC Relay OTP ShutDown Protection OCP Limit OVP ShutDown OK LED Outoput Voltage Regulation Vadj. The product information and specifications are subject to change without prior notice. All products are designed for non-safety critical commercial and industrial applications. The buyer agrees to implement safeguards that anticipate the consequences of any failures that might cause harm, loss of life and/or property damage. PA-6 REV.: 0/2015 www.recom-international.com