Transcript
Redundant Systems Outdoor SSPA Packages
150W Ku-Band Compact Outdoor 1:1 Redundant System
DESCRIPTION Teledyne Paradise Datacom’s Outdoor series of redundant amplifier systems provide the highest degree of earth station redundancy and reliability. Based on Teledyne Paradise Datacom’s family of rugged and robust SSPAs, these systems provide the highest MTBFs possible. These systems can be configured in either 1:1 or 1:2 redundant configurations using any of the Teledyne Paradise Datacom family of Outdoor SSPAs. The RCP2-1100/1200 Redundant Controller provides an extremely user-friendly interface for complete monitor and control of the high power amplifiers in either 1:1 or 1:2 configurations. The RCP front panel mimic display shows the on-line amplifiers and the current switch positions. Dedicated fault lights provide easy indication of system status. All RCP2-1X00 monitor and control is available locally, at the front panel LCD display, as well as remotely by the RS-232 or RS-485 interface ports. Teledyne Paradise Datacom LLC 328 Innovation Blvd., Suite 100 State College, PA 16803 Tel: (814) 238-3450 Fax: (814) 238-3829 1 OF 11
www.paradisedata.com
FEATURES • System Output Power to: 1000W S-Band; 800W C-Band; 800W X-Band; 400W Ku-Band • Universal Input, Power Factor Corrected Power Supply • Output Power Monitoring • Separate 1RU Redundant Controller or Controllerless configurations OPTIONS • System Output Power Monitor • Reflected Power Alarm • L-Band Input Operation • Cold Standby Amplifier Operation • Custom Configurations
Teledyne Paradise Datacom Ltd. 2&3 The Matchyns, London Road, Rivenhall End Witham, Essex CM8 3HA England Tel: +44(0) 1376 515636 Fax: +44(0) 1376 533764 203581 REV AE ECO 17962
Redundant Systems Outdoor SSPA Packages
High Power Outdoor Output Power Levels S-Band: C-Band: X-Band: Ku-Band:
500W - 1000W 400W - 800W 350W - 800W 200W - 500W
Compact Outdoor Output Power Levels S-Band: C-Band: X-Band: Ku-Band:
50W - 500W 30W - 400W 25W - 400W 10W - 250W
System Output Power Capacity Due to residual losses inherent in redundant system configurations (waveguide bends; switch and coupler losses), reduce the typical output power specification of a single amplifier by approximately 0.2 dB for 1:1 and by 0.4 dB for 1:2 systems. For example, a single thread 100W Ku-Band Compact Outdoor SSPA has a typical saturated output power of 50.0 dB (100W). Placing two of the above amplifiers in a 1:1 redundant system configuration would reduce the typical system saturated output by 0.2 dB to 49.8 dB (96W). Placing three of the above amplifiers in a 1:2 redundant system configuration would reduce the typical system saturated output by 0.4 dB to 49.6 dB (91W). Actual system losses will vary based on the system options.
2 OF 11
203581 REV AE ECO 17962
Redundant Systems Outdoor SSPA Packages General Specifications PARAMETER
NOTES
LIMITS
UNITS
minimum full band (all except Extended C-Band) Extended C-Band units per 40 MHz (C-, X-, Ku-Bands) per 10 MHz (S-Band) -40 to +60°C at constant temperature 0.1 dB resolution
70 ± 1.0 ± 1.5 ± 0.3 ± 0.2 ± 1.0 ± 0.25 20
dB dB dB dB/40 MHz dB/10 MHz dB dB/24 hours dB
3 dB back off relative to P1dB
-25
dBc
(@ rated P1dB) (@P1dB - 3 dB)
3.5 1.0
°/dB °/dB
(@ rated P1dB) (@ rated P1dB - 3 dB) (C-,X-,Ku-bands) (@ rated P1dB - 3 dB) (S-band)
-65 -50 -30
dBc dBc dBc
(Extended C-Band with 1.3:1 VSWR option)
1.50:1 1.30:1
at maximum gain (C-,X-,Ku-bands) at maximum gain (S-band)
10 8
dB dB
Linear Parabolic Ripple
0.01 0.003 1.0
ns/MHz ns/MHz2 ns p-p
Transmit Band Noise Output Power Density
TX Band RX Band (C- or Ku-bands) RX Band (X-Band) RX Band (S-Band)
-75 -150 -100 See options
dBW/4 KHz dBW/4 KHz dBW/4 KHz
Receive Band Noise Output Power Density
S-Band, with optional filter S-Band, without optional filter
-155 -95
dBW/4 KHz dBW/4 KHz
0 - 10 KHz 10 KHz - 500 KHz 500 KHz - 1 MHz
-45 -20 (1.25 + log F) -80
dBc dBc dBc
Offset frequency from carrier 10 Hz 100 Hz 1 KHz 10 KHz 100 KHz 1 MHz
-90 -100 -110 -120 -125 -130
dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz
Ambient
-40 to +60
°C
condensing
100
%
Integrated
Forced air
Size, High Power Outdoor, single
width X length X height
Size, Compact Outdoor, single
width X length X height
16.5 X 27.5 X 9.335 419 X 699 X 238 10.0 X 19.5 X 6.50 254 X 495 X 165 100 (45.5) 36 (16.4) ± 3% 44 (20.0) ± 3% 46.7 (21.1) ± 3% 54.9 (25.0) ± 3% +1.7 (0.8) Paint
Gain Gain Flatness Gain Slope Gain Variation vs. Temperature Gain Stability Gain Adjustment Intermodulation Distortion AM/PM Conversion Spurious Harmonics Input/Output VSWR Noise Figure Group Delay (per 40 MHz segment)
Residual AM Noise
Phase Noise
Environmental Operating Temperature Relative Humidity Cooling System
Mechanical
Weight, High Power Outdoor, single Weight, Compact Outdoor, single
Finish
3 OF 11
Base unit (<200W S/C-bands; <100W Ku) Base unit (≥200W S/C-bands; ≥100W Ku) Base unit (<200W X-Band) Base unit (≥200W X-Band) With Internal zBUC
inches mm inches mm lbs. (kg) lbs. (kg) lbs. (kg) lbs. (kg) lbs. (kg) lbs. (kg) White; powder coat
203581 REV AE ECO 17962
Redundant Systems Outdoor SSPA Packages L-Band Operation Teledyne Paradise Datacom offers C-, X-, and Ku-Band amplifiers with an integrated L-Band Block Up Converter. The L-Band units utilize Paradise Datacom’s proprietary ZBUC technology. The addition of a ZBUC® converter to an Outdoor SSPA typically increases the gain by 2-4 dB. The advantages of ZBUC technology include: • A ZBUC converter can detect and switch to an extenally supplied reference. • Optional internal high stability (10MHz) reference. • A ZBUC converter can lock to an externally supplied reference of 5, 10, 20, 25, or 50 MHz without modification. • A ZBUC converter can accept a wide range of external reference power (-10 to +5 dBm) • A ZBUC converter can accept FSK monitor and control signal via the IFL for complete amplifer remote control. Available Frequency Plans Band
Frequency Band
IF Input
LO Frequency
RF Output
Gain Change
C
Standard C-Band
950 - 1525 MHz
4.900 GHz
5.850 - 6.425 GHz
0-4 dB
C
Extended C-Band
950 - 1825 MHz
4.900 GHz
5.850 - 6.725 GHz
0-4 dB
C
Palapa Band
950 - 1250 MHz
5.475 GHz
6.425 - 6.725 GHz
0-4 dB
C
Insat Band
950 - 1250 MHz
5.775 GHz
6.725 - 7.025 GHz
0-4 dB
C
Extended C-Band 2
950 - 1675 MHz
4.800 GHz
5.750 - 6.475 GHz
0-4 dB
X
Standard X-Band
950 - 1450 MHz
6.950 GHz
7.900 - 8.400 GHz
0-2 dB
Ku
Standard Ku-Band
950 - 1450 MHz
13.050 GHz
14.00 - 14.50 GHz
0-2 dB
Ku
Extended Ku-Band
950 - 1700 MHz
12.800 GHz
13.75 - 14.50 GHz
0-2 dB
Electrical Specifications for Outdoor SSPA with ZBUC converter PARAMETER Gain Gain Flatness Gain Slope Gain Adjusted Range Gain Stability Phase Noise
Spurious
NOTES
LIMITS
UNITS
Nominal setting full band (C-,X-,Ku-bands) per 40 MHz (C-,X-,Ku-bands)
75 ± 2.0 ± 0.5 20 60 - 80 57 - 77 ±1.5
dB dB dB/40 MHz dB dB dB dB
Typical C-Band Adj. Range Typical Ku-Band Adj. Range -40 to +60 °C Offset frequency from carrier 10 Hz 100 Hz 1 KHz 10 KHz 100 KHz 1 MHz
Absolute max. -30 -60 -70 -80 -90 -90
C-band (typ.) -60 -80 -80 -85 -120 -125
In-Band Signal Related (C-/Ku-Band) (Extended C-Band) Close to Carrier Spurious (≤ 20 MHz) Local Oscillator
X-band (typ.) -60 -75 -75 -100 -110 -122
Ku-band (typ.) -50 -65 -72 -90 -110 -120
-50 -40 -50 -30
dBc dBc dBc dBm dB
Noise Figure
At 75 dB gain setting
20
Input VSWR
L-Band
1.5 : 1
Aging per day (after 30 days) Aging per year (after 30 days) Reference Stability over Temperature (-20 to +85 °C)
± 1 • 10-9 ± 6 • 10-8 ± 3 • 10-8
Internal Reference Option
4 OF 11
dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz dBc/Hz
203581 REV AE ECO 17962
Redundant Systems Outdoor SSPA Packages Amp 1
RF OUT-POL 1
RF IN-POL 1 Amp 2
RF IN-POL 2
1:1 Redundant HPA System
Amp 3
RF OUT-POL 2
1:2 Redundant HPA System
Teledyne Paradise Datacom’s Outdoor Packaged Redundant Systems are designed with built -in redundancy for 1:1 systems. All system-level monitor and control is internal and no separate controller is required, although an optional RCP2-1100 1:1 Redundant System Controller is available. Either Ethernet or RS-485 communications are selectable for user monitor and control. All 1:2 redundant systems require a separate RCP2-1200 Redundant System Controller.
RCP2-1100 1:1 Redundant System Controller
RCP2-1200 1:2 Redundant System Controller
The RCP2-1200 1:2 Redundant System Controller is the heart of the 1:2 redundant system. It provides an extremely user friendly interface for complete monitor and control of the high power amplifiers. The front panel mimic display shows the on-line amplifiers and the current switch positions. Dedicated fault lights are provided for easy indication of system status. All Redundant System Controller monitor and control is available locally, at the front panel LCD display, as well as remotely by the RS-232, RS-485 or Ethernet interface ports. Audible alarms and a full compliment of parallel I/O signal are available at the rear panel.
5 OF 11
203581 REV AE ECO 17962
Redundant Systems Outdoor SSPA Packages Outline Drawing, 1:2 C-Band Compact Outdoor SSPA System with RCP2-1200
6 OF 11
203581 REV AE ECO 17962
Redundant Systems
MODEL: XXXXXXXXXXXX S/N: XXXX
P/N: LXXXXXX-X
J2
RF OUT J2
Outdoor SSPA Packages
PARADISE DATACOM RCP2-1100 1:1 REDUNDANT SYSTEM CONTROLLER
Outline Drawing, 1:1 C-Band Compact Outdoor SSPA System with RCP2-1100
7 OF 11
203581 REV AE ECO 17962
Redundant Systems Outdoor SSPA Packages Part Number Configuration Matrix, GaAs High Power Outdoor Systems HPA C 2 4 0 0 A H M X S X X Band C-Band C X-Band X Ku-Band K
Configuration Modifier 3 X None (Standard) Generation Second 2
X R1 V W2 Y1 Z2
Power Level (Watts) C-Band 400, 500, 600 X-Band 350, 500 Ku-Band 200, 250 1 2
Configuration Modifier 2 Standard Receive Band Reject Filter Reflected Power Monitor Waveguide Pressure Window R + V (see above) V + W (see above)
X-Band units only Ku-Band standalone units only
Frequency Sub Band C-Band 5.850 to 6.425 GHz 5.850 to 6.725 GHz 5.750 to 6.670 GHz 6.425 to 6.725 GHz 6.725 to 7.025 GHz 5.750 to 6.475 GHz 5.715 to 5.790 GHz 5.740 to 6.650 GHz X-Band 7.90 to 8.40 GHz 7.70 to 8.40 GHz Ku-Band 14.00 to 14.50 GHz 13.75 to 14.50 GHz 12.75 to 13.25 GHz
A1 B1 C E1 F1 G H J 1
A D
A1 B1 F1 1
Configuration Modifier 1 X Standard S Input Sample Port System Configuration 1
A B
1:1 System, Input Switching, Internal control 1:1 System, Input Splitter, Internal control
C1
1:2 System, Input Switching, RCP2-12002
D1 F
1:2 System, Input Switching, Internal control 1:1 System, Input Splitter, RCP2-11002
H1
1:1 System, Input Switching, RCP2-11002
1
Input switching with an external reference BUC requires a reference distribution box. 2 Standard cable length of 100 ft. (30m) with RCP unit.
Available with optional BUC
H
Package High Power Outdoor SSPA
M P X
Block Up Converter Internal Reference BUC External Reference BUC No BUC
Example - A standalone 400W GaAs C-Band High Power Outdoor SSPA an optional input sample port and optional internal reference block up converter is part number: HPAC2400AHMXSXX.
8 OF 11
203581 REV AE ECO 17962
Redundant Systems Outdoor SSPA Packages Part Number Configuration Matrix, GaN High Power Outdoor Systems HPA C 2 8 0 0 A H M B X X X G Band S-Band C-Band X-Band Ku-Band
S C X K
GaN Device Designator G GaN Technology Configuration Modifier 3 X None (Standard)
Generation Second 2
Power Level (Watts) S-Band 600, 800, 1000 (10K) C-Band 650, 800 X-Band 650, 800 Ku-Band 300, 400, 500
X R1 V Y1 1
Configuration Modifier 2 Standard Receive Band Reject Filter Reflected Power Monitor R + V (see above)
S-Band and X-Band units only
Frequency Sub Band A B G
S-Band 2.02 to 2.12 GHz 2.20 to 2.30 GHz 1.75 to 2.12 GHz
A1 B1 C D1 H L
C-Band 5.850 to 6.425 GHz 5.850 to 6.725 GHz 5.750 to 6.670 GHz 6.425 to 7.025 GHz 5.715 to 5.790 GHz 4.400 to 5.000 GHz
1
A D F
A1 B1 C1 D1 F1 G1 1
X-Band 7.90 to 8.40 GHz 7.70 to 8.40 GHz 7.10 to 7.40 GHz Ku-Band 14.00 to 14.50 GHz 13.75 to 14.50 GHz 14.50 to 14.70 GHz 15.10 to 15.40 GHz 12.75 to 13.25 GHz 14.75 to 15.25 GHz
Available with optional BUC
Configuration Modifier 1 X Standard S Input Sample Port System Configuration A
1:1 System, Input Switching, Internal control
B
1:1 System, Input Splitter, Internal control
C D
1:2 System, Input Switching, RCP2-1200 1:2 System, Input Switching, Internal control
F
1:1 System, Input Splitter, RCP2-1100
H
1:1 System, Input Switching, RCP2-1100
1
Input switching with an external reference BUC requires a reference distribution box. 2 Standard cable length of 100 ft. (30m) with RCP unit.
M P X
H
Block Up Converter Internal Reference BUC External Reference BUC No BUC Package High Power Outdoor SSPA
Example — A 800W C-Band (5.85 to 6.425 GHz) 1:1 Redundant High Power Outdoor SSPA System with input splitting, an internal reference block up converter and internal redundancy control is model number: HPAC2800AHMBXXXG.
9 OF 11
203581 REV AE ECO 17962
Redundant Systems Outdoor SSPA Packages Part Number Configuration Matrix, GaAs Compact Outdoor Systems HPA K 2 0 7 0 A C M C S X X Band C-Band C X-Band X Ku-Band K
Generation Second 2
Power Level (Watts) 030, 040, 050, 075, 100, C-Band 140, 200, 250, 300 025, 030, 060, 075, 100, X-Band 140, 200, 250 010, 020, 025, 035, 040, Ku-Band 050, 070, 100, 125
X
Configuration Modifier 3 None (Standard)
A
Side-mount AC Input, Location ‘A’
D
48 VDC Input
F
Side-mount 48 VDC Input, Location ‘A’
X M R1 S 1
Configuration Modifier 2 Standard MS-Connector Covers Receive Band Reject Filter M + R (see above)
X-Band units only
Configuration Modifier 1 X Standard
Frequency Sub Band 1
A B1 C E1 F1 G H J V1,2 1
A B D
A1 B1 1 2
C-Band 5.850 to 6.425 GHz 5.850 to 6.725 GHz 5.750 to 6.670 GHz 6.425 to 6.725 GHz 6.725 to 7.025 GHz 5.750 to 6.475 GHz 5.715 to 5.790 GHz 5.740 to 6.650 GHz 5.850 to 6.725 GHz X-Band 7.90 to 8.40 GHz 7.50 to 8.50 GHz 7.70 to 8.40 GHz Ku-Band 14.00 to 14.50 GHz 13.75 to 14.50 GHz
K
110 VAC Input
1
Available in C- and X-Band models ≥ 140W and Ku-Band models ≥ 100W
System Configuration A
1
B
1:1 System, Input Switching, Internal control 1:1 System, Input Splitter, Internal control
C D1
1:2 System, Input Switching, RCP2-12002 1:2 System, Input Switching, Internal control
F
1:1 System, Input Splitter, RCP2-11002
H1
1:1 System, Input Switching, RCP2-11002
1
1
Input switching with an external reference BUC requires a reference distribution box. 2 Standard cable length of 100 ft. (30m) with RCP unit.
Available with optional BUC With 1.3:1 VSWR
C
Package Compact Outdoor SSPA
Block Up Converter M Internal Reference BUC P External Reference BUC X No BUC
Example — A 70W (14.0 to 14.5 GHz) Ku-Band 1:1 Redundant Compact Outdoor SSPA System with input splitting, an internal reference block up converter, and internal redundancy control is model number: HPAK2070ACMBXXX. 10 OF 11
203581 REV AE ECO 17962
Redundant Systems Outdoor SSPA Packages Part Number Configuration Matrix, GaN Compact Outdoor Systems HPA X 2 3 0 0 A C M C S X X G Band S-Band C-Band X-Band Ku-Band
S C X K
GaN Device Designator G GaN Technology Generation Second 2
X A
Power Level (Watts) S-Band 050, 100, 200, 300, 400, 500 C-Band 300, 400 X-Band 300, 400 Ku-Band 100, 150, 200, 250
X M R1 S 1
Frequency Sub Band A B G
S-Band 2.02 to 2.12 GHz 2.20 to 2.30 GHz 1.75 to 2.12 GHz
A1 B1 C D1 H L
C-Band 5.850 to 6.425 GHz 5.850 to 6.725 GHz 5.750 to 6.670 GHz 6.425 to 7.025 GHz 5.715 to 5.790 GHz 4.400 to 5.000 GHz
A1 D F 1
A B1 F1 G1 1
Configuration Modifier 2 Standard MS-Connector Covers Receive Band Reject Filter M + R (see above)
S-Band and X-Band units only
Configuration Modifier 1 X Standard System Configuration A
1
B
1:1 System, Input Switching, Internal control 1:1 System, Input Splitter, Internal control
C D1
1:2 System, Input Switching, RCP2-12002 1:2 System, Input Switching, Internal control
F
1:1 System, Input Splitter, RCP2-11002
H1
1:1 System, Input Switching, RCP2-11002
1
X-Band 7.90 to 8.40 GHz 7.70 to 8.40 GHz 7.10 to 7.40 GHz Ku-Band 14.00 to 14.50 GHz 13.75 to 14.50 GHz 12.75 to 13.25 GHz 14.75 to 15.25 GHz
Available with optional BUC
Configuration Modifier 3 None (Standard) Side-mount AC Input, Location ‘A’
1
Input switching with an external reference BUC requires a reference distribution box. Standard cable length of 100 ft. (30m) with RCP unit.
2
C
Package Compact Outdoor SSPA
Block Up Converter M Internal Reference BUC P External Reference BUC X No BUC
Example — A 300W X-Band (7.9 to 8.4 GHz) 1:2 Redundant GaN Compact Outdoor SSPA System with input switching, an internal reference block up converter, and redundancy control with a RCP2-1200 controller is model number: HPAX2300ACMCXXXG. Use and Disclosure of Data The information contained herein is classified as EAR99 under the U.S. Export Administration Regulations. Export, re-export or diversion contrary to U.S. law is prohibited. Specifications are subject to change without notice. 11 OF 11
203581 REV AE ECO 17962