Transcript
MINIMUM STARTING TE
REFRIGERATION SOLUTIONS
Operates T8, T10 & T
IceHorse ballasts automatically adjust in cold temperatures to provide optimal light output
® temperature For best results in low applications, you need products that are specifically designed to perform well in the cold. Fulham offers a wide variety of cold-start lighting solutions to choose from, such as LED, Fluorescent, and Induction lighting systems.
Recommended applications include refrigeration cases, freezer cases, cold storage warehouses, coolers, vending machines and outdoor lighting.
)
ICEHORSE 1
ICEHORSE 2
120V-277V Model No. FLUORESCENT ELECTRONIC ± 10% LOW TEMPERATURE Max. Current FLUORESCENT BALLASTS 50/60Hz 120-277 50/60 Hz ELECTRONIC BALLASTS High Power Factor > 0.98 Max. Power • Fulham’s “smart” reactive circuitry APPLICATIONS adjusts in cold temperatures FEATURES ATHD < 10% to provide optimal light output Case Size Circuit temperature Deactivated Lamp Protection •Re-Lamping Minimum starting of -30˚C/-22˚F for T8, T10 and T12 lamps Protection ANSI C62.41-A7 Strikes and EN6100-4-5 •Surge Pre-heat circuit ensures lamp start in low temperature applications Protection Fuseline voltage variations •Current Consistent light output with Weight Lamp Operation Mode Programmed Start Lamp Connection Parallel Case Qty Ignition Method Programmed Pre-Heat Start Lamp Current Crest Factor < 1.7 COMMON SPECIFICATIONS Voltage Transients ANSI 62.41 ICEHORSE 1 ICEHORSE 2 ICEHORSE 3 LAMP OPERATION INDUCTION 120V-277V< 600 VAC LIGHTING SYSTEMS Model No. Model Number # of Lamps Lamp Type / Des Input Voltage Range ± 10% UL / cULus Listed Type 1 Outdoor Current Line Frequency 50/60Hz in tubular, circular and Max. •Power Induction lighting systems bulb varieties Type “CC” Rated High Power Factor > 0.98 Anti-Arch Max. Power •ATHD System options available that operate in temperatures as low as -40˚C < 10% Class “P” Thermal Protection Caselots, Size gas stations, •Re-Lamping Ideal forCircuit large outdoor applications such as parking Deactivated Lamp Protection EMI/RFI Compliance FCC Part 18 non-consumer Surge Protection ANSI C62.41-A7 Strikes and EN6100-4-5 cold storage warehouses, walkways, etc. SoundProtection Rating A Current Fuse Weight Lamp Operation Mode Programmed Start (-22°F) Minimum Operating -30°C Lamp Connection Parallel Temperature Case Qty Ignition Method Programmed Pre-Heat Start Maximum Case Temperature 70°C (158°F) Lamp Current Crest Factor < 1.7 ANSI 62.41Painted Steel LAMP OPERATION < 600 VACWire Leads + Connectors Model Number # of Lamps Lamp Type / Designation Type 1 Outdoor Yes nti-Arch LED DRIVERS Warranty Thermal Protection Class “P” 3 years FCC Part 18 non-consumer •EMI/RFI LEDCompliance drivers with -30˚C minimum operating temperatures Sound Rating A Minimum Operating -30°C (-22°F) Temperature Case Temperature 70°Cmachines, (158°F) •Maximum Designed for vending freezer/refrigerator Ballast Case Construction Painted Steel Input/tput Connections Wire Leads + Connectors Yes Warranty 3 years
UL 600V Wire
UL 600V Wire
cases and more UL
Parallel Wiring
Fulham’s reputation for superior quality is unsurpassed in the refrigeration lighting 1 or 2 Lamp Operat UL 600V Wire (See chart above) segment based on the great lengths we take to ensure reliability. For example, Painted Steel pictured at left is a unique, custom-built refrigeration case specifically designed Low Profile Case by Fulham’s Engineering & Reliability Testing Department to monitor and test performance of Fulham’s lamps and ballasts Parallel in coldWiring conditions.
STANDARD MOLEX CONNECTORS
1 or 2 Lamp Operation (See chart above)
Painted Steel Low Profile Case
STANDARD MOLEX CONNECTORS
See Fulham Catalog or www.fulham.com for Ordering Instructions
order APP-REF-1211