Preview only show first 10 pages with watermark. For full document please download

Refs. 554501 554601

   EMBED


Share

Transcript

Refs. 554501 554601 EN DVB-T Modulators User´s Manual w w w. t e l e v e s . c o m Index 1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.1 Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.2 Blocks diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.3 Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2. Product description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2.1 Indicators and controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2.2 Installation precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 3. Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 3.1 Button introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 3.2 Initial status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 3.3 General setting for main menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 4. Encoders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 4.1 Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 5. Web nms operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 5.1 Login . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 5.2 Configuration setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 6. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 7. Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 7.1 Ordering guideline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 7.2 Application example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 7.3 Configuration example for more than one unit in the same installation . . . . . . . . . . . . . . . . 13 ENGLISH EN DVB-T Modulator 4 1.3 Technical specifications 1. Introduction 1.1 Product overview The product is presented for two types of mounting: onto the wall (Ref. 554501), and 19 inch cabinet mounting (Ref. 554601). The modulator converts the HD A/V baseband signals into a DVB-T multiplex of RF within the range 30 ~ 960 MHz. It features 2 encoders, which are accessed by F-type connectors, and 1 additional RF input. The signals can come from satellite receivers, CCTV cameras, Bluray players, antennas, ... etc. Its output is a DVB-T TV multiplex which can be received with the corresponding DTT STB. The device can be used for monitoring, training courses and presentations, schools, universities, hospitals, ..., in addition to being the best choice for public premises which offer sporting events, VIP entertainment channels,.. and other. 1.2 Blocks diagram     DVB-T modulator section Standard EN300744 FFT mode 2K, 8K Bandwidth 6M, 7M, 8M Constellation QPSK, 16QAM, 64QAM Guard Interval 1/4, 1/8, 1/16, 1/32 FEC 1/2, 2/3, 3/4, 5/6, 7/8 MER ≥42dB RF frequency 30~960MHz, 1KHz step RF output level -30~ -10dBm (81~97 dBμV), 0.1dB step Interface Front panel buttons, LCD display Remote management Web NMS Language English, French General      Mains AC 100V~240V Dimensions 360 x 280 x 50 mm (554501) 480 x 300 x 44 mm 1U rack 19” ( 554601) Weight 2.6 kgs Operating temperature 0~45 ºC Configurations LCN config Yes NIT Table config Yes Settings  Network Name Yes Network ID Yes Transport Stream ID (TSID) Yes Original Network ID (ONID) Yes Hierarchy Information Yes 5 2. Product Description 2.1 Indicators and controls 554501 14 15 2 3 12 13 EN 1 5 4 9 8 6 7 10 554601 11 2 1 10 3 4 11 5 6 7 8 9 12 13 14 15 1 LCD display 6 Up/Down and Left/Right buttons 11 Encoder 2 slot (with tap) 2 NMS port 7 ENTER button 12 RF input 3 IP port 8 MENU button 13 RF output 4 ON LED and alarm LED 9 Locking button 14 ON/OFF switch 5 Locking LED 10 Encoder 1 slot (open) 15 Mains socket DVB-T Modulator 6 2.2 Installation precautions 3.2 Initial Status This section to explain the cautions the users must have to avoid any injures when using or installing the product. For this reason, please read all details here before installing or using the product. Switch On, then below status will be displayed, few seconds’ initialization then open startup picture  General Precautions Must be operated and maintained free of dust or dirty. T he cover should be securely fastened, do not open the cover of the products with the power on. After use, securely stow away all loose cables, external antenna, and others.         Power precautions  hen you connect the power source, make sure it will not cause any overload. W Avoid operating on a wet floor in the open. Make sure the extension cable is in good condition. Make sure the power switch is off before you start to install the device. Grounding Requirement All function modules’ good grounding is the basis of reliability and stability of devices. Also, they are the most important guarantee of lightning arresting and interference rejection. Therefore, the system must follow this rule. Grounding conductor must be a copper conductor in order to reduce high frequency impedance, and the grounding wire must be as thick and short as possible. Users should make sure the both ends of grounding wire are electric conductor and antirust. It is prohibited to use any other device as part of grounding electric circuit. The area of the conduction between grounding wire and device’s frame should be no less than 25mm2    3. Operation  3.1 Button introduction LCD display window. Display window for setting menu Status display when power On.   Setting value up and moving up To move left To move right  VB-T: indicate the modulation standard of this device D XXX.XX MHz: indicate the output frequency, and the frequency range is 30~960MHz X.XX Mbps: indicate the encoding bit rate in slot 1 Y.YY Mbps: indicate the encoding bit rate in slot 2    3.3 General setting for Main Menu By pressing “Lock” key to enter the main   menu, the LCD will display the following pages:                             ­        User pressing UP or DOWN buttons to specified menu item, and then pressing ENTER to enter the submenus as below:     1) Alarm status --- the alarm indicator will light on if there is no A/V signals  ­  input. 2) Encoder setting --- choose this submenu, the LCD will show “input setting”, press the ENTER key and control the UP or Down key to move the arrow. User could find how to set the audio and video encoding bit rate.   3) Modulator setting     When the “modulator setting” submenu has been chosen, users can find below different parameters for setting. And the LCD   window would respectively show like these.                      ­€         -B  andwidth There are three possible options provided for selecting bandwidth: 6M, 7M, and 8M. When the display shows them, user just need swift LEFT and RIGHT key to ­€   choose and repressing “ENTER” for confirm. Setting value down and moving down Back step Confirm setting Lock button   -C  onstellation Three different constellations: QPSK, 16QAM, and 64QAM will be show on the LCD window when Constellation been entered. -Q  PSK: Quadrature Phase Shift Keying, Selecting this option indicates the device works as DVB-S modulation mode -1  6QAM: Quadrature Amplitude Modulation is 16 -6  4QAM: Quadrature Amplitude Modulation is 64   7 Setting method just the same, when the display shows them, user just need swift LEFT and RIGHT key to choose and repressing “ENTER” for confirm. -G  ateway If the device is in different net segment, you must set the gateway. - Transmission mode After entering Trans mode, the LCD would show the current working mode. User can move LEFT/RIGHT key and repress ENTER key to select and confirm. 2K and 8K are the options. - 2K: when the device works as current mode, the number of current carrier is 2048. - 8K: when the device works as current mode, the number of current carrier is 8192. -P  ort The UDP protocol port (like as 8001), you should use Output IP and new port to receive IP Output data (like as udp://224.2.2.2:8001). - Guard interval In communications, guard intervals are used to ensure that distinct transmissions do not interfere with one another. These transmissions may belong to different operators (as in TDMA) or same operator (as in OFDM). The purpose of the guard interval is to introduce immunity to propagation delays, echoes and reflections, to which digital data is normally very sensitive. There are four possible options provided to be selected. They are 1/4, 1/8, 1/16, 1/32. User can shift the LEFT/RIGHT key to select and press ENTER to confirm. - FEC Forward Error Correction (FEC) rates include 1/2, 2/3, 3/4, 5/6, and 7/8. After entering FEC submenu, and the LCD display would shows them, users just need press LEFT and RIGHT button to choose, and press ENTER button for confirm. - RF Frequency The RF output frequency range is from 30 to 1000MHz with 1K stepping. After entering the RF frequency setting submenu, users the can press LEFT, RIGHT, UP, and DOWN buttons to adjust the frequency and confirm by press ENTER button. - RF out level The RF attenuation range is from -30~-10dBm (81~97dBμV) with 0.1dB step. After entering this setting submenu, user can shift UP/DOWN/LEFT/RIGHT key to set the output level and press ENTER to confirm. 4.3Output OutputIPIP 4.3 4.4Subnet SubnetMask Mask 4.4 5) Network setting After inter network setting, there are three  Submenu Items for setting, just EN show as the following LCD display pictures.                             User can press “UP/DOWN” to choose this    item. “Enter” and “LEFT/RIGHT” to set the    parameters.  Note: The MAC address is according to the factory setting, and it’s unique. The    display will respectively show as below:                      ­    6) Save config   Users enter save config submenu for saving    settings. Choose yes for confirm set. 4) IP Output Setting 4.1IPIPOutput Output 4.1 4.2Service ServiceIPIP 4.2       4.5Gateway Gateway 4.5 4.6Port Port 4.6    User can press “UP/DOWN” to choose this item. “Enter” and “LEFT/RIGHT” to      set the parameters.      If not set the following parameters will be no use, the IP Output will not work.                          - IP Output The    IP Output option, must be enable.  - Service IP The    IP Output Port address. The format is xxx.xxx.xxx.xxx (like as 192.168.2.137). IP - Output The   IP Output data receive address. The format is xxx.xxx.xxx.xxx (like as 224.2.2.2). After set the Output IP address , you must use the new address to receive IP Output data. - Subnet Mask General is 255.255.255.0, it is must the same in a local area network.             ­            7) Loading config At this menu, user can press UP/DOWN key  to select and repress ENTER to confirm. User can restore the device into the last saved configuration by choosing “7.1” and restore the device into factory configuration by choosing “7.2” the display will show as below:                                8) Version User can check the hardware version and software version of this equipment  when enter this submenu. EncoderModulator SW 5.13b HW 5.0 1 Conf Entrad 2 Conf ASI DVB-T Modulator 8 4.1 Specification 4. Encoders 554801 554802 554803 Video Compression MPEG-2 SD MPEG-2 SD H264 HD Audio Compression MPEG-2 SD MPEG-2 SD MPEG-2 SD Ref. Ref. 554801 – 1 A/V Input Encoding mode MPEG-2 / H264 / AVC SD / HD   Port 1 2 1 Option 1 Port 2 (1) CVBS input (video input) (2) Unbalanced audio input (left and right) Port 1 Option 2  Port 2  2 Unbalanced audio input  Unbalanced audio input Two channel CVBS input Unbalanced audio input One channel of HDMI input Port 2 One channel of HDMI input  RF input Port 1 4 3 Two channel CVBS input Port 1 Input port 1 One channel CVBS input RF input Option 3  Unbalanced audio input RF input Ref. 554802 – 2 A/V Inputs  One channel CVBS input (1) CVBS input (video input) –Channel 1 (2) Unbalanced audio input (left and right) –Channel 1 (3) CVBS input (video input) –Channel 2 (4) Unbalanced audio input (left and right) –Channel 2 Ref. 554803 – 1 HDMI Input Option 4 Port 2 Two channel CVBS input Unbalanced audio input One channel CVBS input Unbalanced audio input RF input Port 1 Option 5 Port 2 One channel of HDMI input Two channel CVBS input Unbalanced audio input RF input Port 1 Option 6  1  2 (1) HDMI input –Channel 1 (2) HDMI input –Channel 2 Input resolutions: 1280x720p60, 1280x720p50, 1920x1080i60, 1920x1080i50, 1920x1080p60, 1920x1080p50 Note: Is only possible to obtain on the output the signal of one input at a time. W  hen both input have signal at the same time, the signal on the output is the one of HDMI1(if HDMI input is set in automatic see chapter 5.2, otherwise the output will be from the input selected). Port 2 One channel of HDMI input One channel CVBS input Unbalanced audio input RF input IMPORTANT:  This equipment generates a delay of about 2 seconds between the signal at inputs A/V and HDMI, and their corresponding outputs in RF and IP. For this reason, the use of game consoles (eg PS3, XBox360 ...) as signal sources is not recommended, because only watching movies is achieved, not being able to really play.” 9 5. WEB NMS operation User not only can use front buttons for setting configuration, but also can control and set the configuration in computer by connect to web NMS Port. User should ensure that the computer’s IP address is different from the NDS3542’s IP address; otherwise, it would cause IP conflict. 5.1 Login A login interface will pop up firstly when user entered the IP address: http://192.168.0.136 (or shown in 5.1 IP Address menu), the interface shows as follow picture. Both of the default user name and password are admin. User will face welcome interface after login, and all setting options are been listed on the left side. And the main window at the right shows version information and status information. (All the example pictures been showed here just window captures pictures when the device connected in our test room, status shows on the picture just for reference, they are not fixed value). 5.2 Configuration setting 1) HDMI input setting  DMI Input: Display which HDMI port is used (Only for HDMI Band Input). H H.264 Profile: user can set the H.264 Profile in this area, there are four possible options provided to be selected: Automatic, High Profile, Main Profile and Baseline Profile. H.264 Level: user can set the H.264 Level in this area, there are twelve possible options provided to be selected: Automatic, Level 1.2, Level 1.3, Level 2, Level 2.1, Level 2.2, Level 3, Level 3.1, Level 3.2, Level 4, Level 4.1 & Level 4.2. Video bit rate: user can set the video bit rate in this area, the range is 1~19.5Mbps. Audio bit rate: user can set the audio bit rate in this area, there are five possible options provided to be selected: 64kbps, 96kbps, 128kbps, 192kbps, 256kbps EN and 320kbps. The default value is 128kbps. Program name: it shows current program information. User can select and type the program name to be played as needed. PMT/Video/Audio/PCR PID: in this area, user can set program PIDs as needed, usually system will automatically select the default values. Encoding and video light: the light should show green colour normally HDMI input: it shows if there is real-time HDMI signal inputting Video format: the current video format of the device Bit rate: the current encoding bit rate 2) 1 A/V input setting  ideo Bit Rate: The range of values from 1.000 to 19.500 Mbps. For SD signal, V 3.000 Mbps is ok, HD signal at least need 6.000 Mbps. Audio Bit Rate: Audio encode bit rate configuration. You can select the suitable audio bit rate from list. Brightness: The range of values from 0 to 255 (Only for SD signal). Contrast: The range of values from 0 to 255 (Only for SD signal). Saturation: The range of values from 0 to 255 (Only for SD signal). Hue: The range of values from -127 to 127 (Only for SD signal). Aspect Ratio: User can set the Aspect ratio. There are 4 possible options to be selected: 1:1, 4:3, 16:9 and 2.21:1. Program Out Enable: Enables / Disables the program out. Program Name: Only support character and number. The length can not over 32 byte Service ID: Also called program number, it is must different from other program. If you change it,you should modify the LCN. PMT PID: Program Mapping Table PID Video: Green is normal, red means signal input error, please check signal input and video format. Encoding: Green is normal, red means encoder is not work, please check signal input and video format. Norm: Display the video format of the input (Only for SD signal). Video Format: Display the video format of the input (Only for HD signal). Bit rate: Display the current encoder Bit rate. DVB-T Modulator 10 3) 2 A/V input setting  ideo Bit Rate: The range of values from 1.000 to 19.500 Mbps. For SD signal, V 3.000 Mbps is ok, HD signal at least need 6.000 Mbps. Audio Bit Rate: Audio encode Bit rate configuration. You can select the suitable audio Bit rate from list. Brightness: The range of values from 0 to 255 (Only for SD signal). Contrast: The range of values from 0 to 255 (Only for SD signal). Saturation: The range of values from 0 to 255 (Only for SD signal). Hue: The range of values from -127 to 127 (Only for SD signal). Sharpness: There are 4 possible options to be selected: Off, Smooth, Medium and Sharp. Aspect Ratio: User can set the Aspect ratio. There are 4 possible options to be selected: 1:1, 4:3, 16:9 and 2.21:1. Program Name: Only support character and number. The length can not over 32 byte. Service ID: Also called program number, it is must different from other program. If you change it, you should modify the LCN. PMT PID: Program Mapping Table PID. Video: Green is normal, red means signal input error, please check signal input and video format. Encoding: Green is normal, red means encoder is not work, please check signal input and video format. Norm: Display the video format of the input (Only for SD signal). Video Format: Display the video format of the input (Only for HD signal). Bit rate: Display the current encoder Bit rate. 4) NIT table setting  etwork ID: This is a 16-bit field which identifies the terrestrial network that N supports the service indicated. User can click “Add” to pop up a table, following is the interface: T ransport stream ID: This 16-bit field which serves as a label identifying the TS which contains the service, event or mosaic described by the cell. Original network ID: This is also a 16-bit field, a label which in conjunction with the following fields uniquely identifies a service, event or mosaic. RF Frequency: user can set the RF frequency in this menu. The range is 30~960MHz with 1 KHz step. Bandwidth: there are three possible options provided to be selected: 6M, 7M and 8M. Constellation: there also have three possible options to be selected: QPSK, 16QAM and 64QAM. Hierarchy information: this option only adopts ISDB-T standard device. Code rate: user can select the FEC value in the pull-down menu. There are five possible options provided to be chosen: 1/2, 2/3, 3/4, 5/6 and 7/8. Guard interval: user can select the guard interval value in the pull-down menu: 1/32, 1/16, 1/8 and 1/4. Transmission mode: user can decide transmission mode 2k or 8k. Service ID: unique identifier of a service within a TS. LCN: logical channel number. Add: User can add a logical number in system by clicking “Add” menu and typing the program information. The LCN can be added more than one by re-clicking “Add” option. The interface shows as below:  el: clicking “Del” to delete the added LCN information. D Save: clicking “Save” to save the current NIT parameters. Cancel: clicking “Cancel” to exit the edit interface. The display will show as below when user saved the NIT settings.  pdate NIT: clicking to update the NIT tables in system. U Save NIT: clicking to save the settings. Clear NIT: clicking to remove all the table have been inserted before. The location of the NIT is defined in the present document in compliance with ISO/IEC 13818-1 [1] specification, but the data format is outside the scope of ISO/IEC 13818-1 [1]. It is intended to provide information about the physical network. The syntax and semantics of the NIT are defined in the present document. Network name: The name of current network, user can change it as he likes. 11 5) IP out setting possible options provided to be chosen: 1/2, 2/3, 3/4, 5/6 and 7/8. RF frequency: the range is 30~1000MHz. RF output level: the range is -30~-10dBm. 7) Save/Restore EN 8) Reboot Follow the help guideline for set IP out configuration.  Output: The IP Output option, must be enable. IP Service IP: The IP Output Port address. The format is xxx.xxx.xxx.xxx (like as 192.168.2.137). Output IP: The IP Output data receive address. The format is xxx.xxx.xxx.xxx (like as 224.2.2.2). After set the Output IP address , you must use the new address to receive IP Output data. Subnet Mask: General is 255.255.255.0, it is must the same in a local area network. Gateway: If the device is in different net segment, you must set the gateway. Port: The UDP protocol port (like as 8001), you should use Output IP and new port to receive IP Output data (like as udp://224.2.2.2:8001). Note: The signal available at the IP Output is the same as the RF output. T he protocol used for the MUX stream is UDP, so to see the modulated channels you need a program that has this protocol, like VLC Media Player. I n recent versions of this particular program is necessary to put @ before the IP address, for example, “udp :/ / @ 224.2.2.2:1234”. Important: Not all computers have the ability to view a service provided by a 554803. 6) Modulator setting  andwidth: there are three possible options provided to be selected: 6M, 7M B and 8M. Constellation: there also have three possible options to be selected: QPSK, 16QAM and 64QAM. FFT: user can set the FFT (transmission mode) by selecting in the pull-down menu. Guard interval: user can select the guard interval value in the pull-down menu: 1/32, 1/16, 1/8 and 1/4. FEC: user can select the FEC value in the pull-down menu. There are five 9) Firmware This function is used to upgrade the device’s latest software program. If user wants to update the device to latest version, he should contact with manufacturer to get the latest version software. When upgrading it, user can click the “ ” button to select the program needs burned into system. Note: User should strictly follow the “Warning” information. DVB-T Modulator 12 10) Network This interface indicates the default IP address and network mask of this device. User can revise it and click “Apply” to confirm. 6. Troubleshooting Televés’ ISO9001 quality assurance system has been approved by CQC organization. For guarantee the products’ quality, reliability and stability. All Televés products have been passed the testing and inspection before ship out factory. The testing and inspection scheme already covers all the Optical, Electronic and Mechanical criteria which have been published by Televés. To prevent potential hazard, please strictly follow the operation conditions. Prevention Measure 11) Password User can revise the login password in this menu by type accordingly information as required and click “Apply” to confirm. I nstalling the device at the place in which environment temperature between 0 to 45 °C Making sure good ventilation for the heat-sink on the rear panel and other heat-sink bores if necessary Checking the input AC within the power supply working range and the connection is correct before switching on device Checking the RF output level varies within tolerant range if it is necessary Checking all signal cables have been properly connected Frequently switching on/off device is prohibited; the interval between every switching on/off must greater than 10 seconds. Conditions need to unplug power cord  ower cord or socket damaged. P Any liquid flowed into device. Any stuff causes circuit short Device in damp environment Device was suffered from physical damage Longtime idle. After switching on and restoring to factory setting, device still cannot work properly. Maintenance needed 7. Application 7.1 Ordering guideline Our design is individual module, for this series device the encoding module including three version for optional:  PEG2 SD encoding with 1 CVBS module M MPEG2 SD super encoding with 2 CVBS module MPEG4 AVC H.264 encoding with 1 HDMI module Modulation module including one version for optional: DVB-T COFDM RF out module 13 7.2 Application example Eventual roof antenna DVD EN Advertisement System HDMI Source Monitor TV and / or TV Camera CVBS Source Channel injection Hard Disk Sender TV Antenna Wall socket Blue DVD Pay Channel STB IP (optional) IRD STB Network Wireless router 7.3 Configuration example for more than one unit in the same installation Unit 1 Unit 2 TV DVB-T Modulator 14 7.3.1 NIT Configuration In this menu is possible to edit the LCN of each program (in order to be listed correctly the Hierarchy Information must be set to “a-1, a-2 or a-4”, the same on each unit of the same network). The LCN can be set by any order, in the image above it can be observed that the unit 2 will have program 1, 3 and 4 and unit 1 will have program 2. In this menu is possible to edit the Transport Stream ID, Original Network ID (each unit has to have a different TSID and ONID), assign a Network name (the same in all units of the same network) and more. After each change is necessary to press Update NIT. By pressing “Add” you will have access to the menu of the next images: 7.3.2 NIT, Hierarchy and LCN Configuration After pressing “save” on the previous menu, is necessary to press “Update NIT” again, and then in the “Save/Restore” menu press “Save config”. 15 7.3.3 List Aspect on TV/Receiver EN List aspect with LCN List aspect without LCN On these two images it can be seen the two possible ways to list the programs: • With LCN – the programs are listed in order according with the LCN configuration set above. • Without LCN – the programs list will depend on the TV/STB and it can be based on: - Alphabetic order - MUX frequency - First the HD programs, listed based on the MUX frequency - Then the SD programs, listed based on the MUX frequency DVB-T Modulator 16 17 EN DVB-T Modulator 18 19 EN televes.com 564501_564601_003_EN