Relay Panel 32

   EMBED


Share

Transcript

Relay Panel 32 BlueRidge Technologies Project Part Number Ref. Data Sheet Overview Relay Panel (RP) is a UL Listed lighting control panel. RP may be controlled from any BACnet BAS and is compatible with all low voltage switches. RP mounts near the circuit breaker panel to provide centralized control of branch lighting circuits. Relay Panel 32 (RP32) features 16, 24, or 32 Lighting Tough Relays (LTR) in a black powder coated steel enclosure with a hinged reversible door. Features UL Listed BACnet MS/TP and BACnet ARCnet communication to BAS network Sub network for Capacitive Touch Stations (CTS-DDN) Line and low voltage compartment separation Upgradable controller firmware Optional UL924 Emergency Bypass General Specifications Construction: 16ga steel with black powder coat finish Dimensions: Enclosure: 25.00”(635mm)H x 18.00”(457mm)W x 5.75”(146mm)D Door Surface Mount: 25.25”(641mm)H x 18.08”(459mm)W Door Recessed (Flush): 26.50”(673mm)H x 19.58”(497mm)W Weight: 47.5lbs(21.5kg) Mounting: Surface or recess mounted Operating Environment: 32-125°F (0-50°C), 20-95%RH, non-condensing, Type 1 (dry / indoor environment) Certifications UL Listed, UL916 Standard for Energy Management Equipment, US/Canada FCC Part 15 CEC Title 24 Electronics meet or exceed IEC Level 3 Warranty Two (2) year limited manufacturer warranty from date of shipment (extended warranty optional). Controller Specifications Power In: 24VAC +/-10%, 30VA, 50-60 Hz Auxiliary Out: 24VAC, 800mA (devices with full wave rectified power supply only) Digital Input (DI) and DDN Network Power Out: 24VDC, 200mA total Digital Input: 24 two-wire inputs Software Configuration: Maintained, state change, momentary on/off, momentary on, or momentary off Jumper Configuration: 8 input segments, dry contact (N) or 24VDC externally powered (R) Wire Requirement / Maximum Length: 18AWG (Solid or Stranded) / Dry Contact 500’(152m) or externally powered 1,000’(304m) Analog Input: 6 three-wire 0-5VDC inputs Power Out: 5VDC, 50mA total Wire Requirement / Maximum Length: 18AWG (Solid or Stranded) / 250’(76m) BAS Network Specifications BACnet MS/TP Baud Rate: DIP switch selectable 9.6K, 19.2K, 38.4K, or 76.8K Device Profile: BACnet Advance Application Controller (AAC) Address Range: 1 – 99 selectable with rotary dials Unit Load: Full unit load, 32 devices per MS/TP segment Topology: RS-485, half duplex, daisy chain wiring Wire Requirement / Maximum Length: CL3P, 22AWG, 2 conductor, shielded, low cap / 4000’(1216m) Points: See Integration Guide and PIC Statement See Automated Logic Corporation’s ARC156 Wiring Technical Instructions for the latest BACnet ARCnet specifications. DDN Network Specifications Compatible with CTS-DDN and DDN devices. See data sheet for details. LEXP Specifications Description: 1 Digital Input Expansion Card (standard) Digital Input: 32 two-wire inputs Software Configuration: Maintained, state change, momentary on/off, momentary on, or momentary off Jumper Configuration: 8 input segments, dry contact (N) or 24VDC externally powered (R) Wire Requirement / Maximum Length: 18AWG (Solid or Stranded) / Dry Contact 500’(152m) or externally powered 1,000’(304m) Transformer Specifications Type: 30VA Inherently Limited Primary: Dual Tap 120 or 277VAC +/-10%, 30VA, 50-60 Hz Secondary: 24VAC +/-10% Inherently Limited Wire Requirement: 18AWG Minimum (Solid or Stranded) LTR Specifications Type: UL Listed SPST latching with manual override lever Electrically operated mechanically held, pulse driven Short Circuit Current Rating (SCCR) 20,000A @ 277 VAC Ratings: Tungsten 20A @ 120VAC / Ballast 20A @ 277VAC / Ballast 20A @ 347VAC / Resistive 20A @ 277VAC / Resistive 20A @ 347VAC Load Terminal: Universal screw terminal, box type clamp Terminal Capacity (per side): (2) 14-10AWG or (1) 8AWG (Solid or Stranded copper wire) Optional Equipment Specifications UL924 Emergency Bypass provides energy management control of emergency lighting circuits during normal operation while maintaining emergency function during power loss. See the UL924 Data Sheet for details. Relay Panel 32 www.BRTint.com : 800-241-9173 Blue Ridge Technologies® Data Sheet H1 Earth Ground Retrofit Interior (RI) Relay Panel (RP) 4 5 6 7 8 SW1 SW3 1 2 3 AUTO 78 78 3 456 2 456 SW4 OVER Field Devices Relays 33-64 CTS-DDN (Capacitive Touch Station) RELAYS 33-64 17-24 R 24VAC(+) Auxiliary Out 24VAC(-) Auxiliary Out AUX VAC Field Devices DDN Network H2 H1 GND DI 56 DI 55 DI 54 DI 53 DI 52 DI 51 DI 50 DI 49 DI 33 DI 34 DI 35 DI 36 DI 37 DI 38 DI 39 DI 40 GND DI 25 DI 26 DI 27 DI 28 DI 29 DI 30 DI 31 DI 32 GND GND DI 56 DI 55 DI 54 DI 53 DI 52 DI 51 DI 50 DI 49 Address Controller Board Port Jumper Baud Rate / Protocol Network Address Rotary Switch 10’s Field Devices GND DI 48 DI 47 DI 46 DI 45 DI 44 DI 43 DI 42 DI 41 DI Jumper 41-48* DI Jumper 49-56* Power LED DI Jumper 25-32* DI Jumper 33-40* BAS Protocol *DI Jumper Position N(Dry Contact) / R(Externally Powered) DDN Network Retrofit Interior (RI) IP INPUTS 1-16 Lighting Load N R Normal Power Distribution Panel J4 UL924 Internet J5 DILighting JumperTough Relay 33-40* (LTR) POWER Relay Panel (RP) DDN Network Relay Panel (RP) LS5 J9 Power LED DI Jumper 25-32* Field Devices DDN Network G J13 DI 25 DI 26 DI 27 DI 28 DI 29 DI 30 DI 31 DI 32 GND OCC Earth Ground DI Jumper 41-48* DI Jumper LVS (Low Voltage Switch) / OCC (Occupancy Sensor) / LS5 (Light Sensor) Normal (Utility) Power 49-56* J18 J19 B D Controller Terminations Test Jumper Field Devices Terminations Generator 347VAC Brown Emergency Power NeutralEmergency Black LVS Transfer Switch Distribution Panel *DI Jumper Position N(Dry Contact) / R(Externally Powered) TEST JP2 Retrofit KitLEXP (RK) A C ADDRESS INPUTS 1-16 N R BAS Router Manual Override Lever Field Devices DDN Network R N POWER J4 J5 Wire Strip Length Indicator IP BAS Protocol * See Price List for Recessed (Flush) door panels. TO J26 OF Controller J9 J13 J18 J19 B D Relay Output A C ADDRESS Line In Earth Ground CTS-DDN (Capacitive Touch Station) TO J26 OF Controller LTR Terminations General Architecture R N Neutral Black Earth Ground Line Voltage Bay at Top of Panel with Dead Front Cover Internet XX = 0H None INPUTS 17-32 Neutral White 120V White CTS-DDN LS5 OCC Relay Panel (RP) Retrofit Interior (RI) Transformer Terminations 347 Transformer Terminations LEXP Terminations Emergency Bypass Structure DDN Network Field Devices 277V Brown INPUTS 17-32 Neutral Black Field Devices DDN Network 240V Orange 208V Red 277VAC Brown 120VAC Black 3 4 5 6 7 8 9 10 11 12 13 14 15 16 G DI 9 DI 10 DI 11 DI 12 DI 13 DI 14 DI 15 DI 16 GND 1 2 GND DI 1 DI 2 DI 3 DI 4 DI 5 DI 6 DI 7 DI 8 GND DI 17 DI 18 DI 19 DI 20 DI 21 DI 22 DI 23 DI 24 BAS Router G 347VAC Brown BAS 24VAC(+) Power In 24VAC(-) Power In N N GND DI 48 DI 47 DI 46 DI 45 DI 44 DI 43 DI 42 DI 41 1-8 R LVS Low Voltage Section at Bottom of Panel LVS (Low Voltage Switch) Sensor) / LS5 (Light Sensor) XX /=OCC 0L (Occupancy None LEXP Port INPUT POWER 24VAC G 17 18 19 20 21 22 23 24 9-16 R X0 UL924 - Last 16 relays only AI (Analog Input) / DI (Digital Input) / GND (Ground) *DI Jumper Position N(Dry Contact) / R(Externally Powered) CTS-DDN J26 LEXP Retrofit Kit (RK) XX = 00 None Field Devices Relays 1-32 DI Jumper 9-16* Earth Ground DDN Network Retrofit Interior (RI) Options Special DDN NetworkRELAYS 1-32 N BAS DDN Network GND DI 48 DI 47 DI 46 DI 45 DI 44 DI 43 DI 42 DI 41 Power LED Relay Panel (RP) Run LED DI 33 DI 34 DI 35 DI 36 DI 37 DI 38 DI 39 DI 40 GND DDN Network RUN 32 32 Relays Installed Field Devices Override Controls J2 DI Jumper General Architecture 17-24* DI Jumper 1-8* DI 25 DI 26 DI 27 DI 28 DI 29 DI 30 DI 31 DI 32 GND XX = 16 16 Relays Installed Address Controller Board Port Jumper DDN/CAN 5V A6 A5 A4 A3 A2 A1 G IP BAS Protocol 24 24 Relays Installed 1 2 3 4 5 6 7 8 5VDC AI 6 AI 5 AI 4 AI 3 AI 2 AI 1 GND Internet Actual Quantity of Relays Installed 901 901 23 1 BT485 S B- A+ PWR DDN Network Terminator Jumper DI Jumper 33-40* LC32P - XX - XX - XX - XX Rotary Switch 1’s ON Field Devices 24VDC DDN Network(-) DDN Network(+) GND Power LED DI Jumper 25-32* Ordering Information* Baud Rate / Protocol Network Address Rotary Switch 10’s Dip Switch Network Address BT485 BAS Router Terminator Plug (if applicable) INPUTS 1-16 Controller Terminations General Architecture BAS LS5 OCC DI Jumper 41-48* DI Jumper 49-56* Jumper Position N(Dry Contact) / R(Externally Powered) LVS (Low Voltage Switch) / OCC (Occupancy Sensor) / LS5*DI (Light Sensor) CTS-DDN (Capacitive Touch Station) BAS (+) In/Out BAS (-) In/Out Shield Out N R LVS J4 CTS-DDN J5 Wire Strip Length Indicator Manual Override Lever J18 J19 B D Field Devices Relay Output A C ADDRESS DDN Network Line In Retrofit Kit (RK) POWER Field Devices DDN Network J9 Field Devices DDN Network J13 LTR Terminations Field Devices DDN Network TO J26 OF Controller Earth Ground R N Neutral Black Earth Ground Neutral Black INPUTS 17-32 BAS BAS Protocol 347VAC Brown 120V White Neutral White BAS Router IP DI 33 DI 34 DI 35 DI 36 DI 37 DI 38 DI 39 DI 40 GND 120VAC Black H2 240V Orange 208V Red GND DI 56 DI 55 DI 54 DI 53 DI 52 DI 51 DI 50 DI 49 Internet 277V Brown 277VAC Brown LEXP Terminations 347 Transformer Terminations 23 H2 Transformer Terminations Address Controller Board Port Jumper Transformer Terminations General Architecture Transformer Terminations nsformer Terminations UL924 Terminations H1 © 2014 Blue Ridge Technologies International, LLC All Rights Reserved. LC-RP32-DS-V14.02 Retrofit Kit (RK)