RH Series Compact Power Relays SPDT through 4PDT, 10A contacts Compact power type relays The RH series are miniature power relays with a large capacity. The RH relays feature 10A contact capacity as large as the RR series but in a miniature package. The compact size saves space.
Part Number Selection Part Number Contact
Blade Terminal
Model Basic
DPDT
3PDT
4PDT
RH1B-U
Coil Voltage Code (Standard Stock in bold)
RH1V2-U
With Indicator
RH1B-UL
—
With Check Button
RH1B-UC
—
With Indicator and Check Button
RH1B-ULC
—
Top Bracket Mounting
RH1B-UT
—
With Diode (DC coil only)
RH1B-UD
RH1V2-UD
DC6V, DC12V, DC24V, DC48V, DC110V DC12V, DC24V, DC48V, DC110V
AC6V, AC12V, AC24V, AC110V, AC120V, AC220V, AC240V DC6V, DC12V, DC24V, DC48V, DC110V
With Indicator and Diode (DC coil only)
RH1B-ULD
—
Basic
RH2B-U
RH2V2-U
With Indicator
RH2B-UL
RH2V2-UL
With Check Button
RH2B-UC
—
With Indicator and Check Button
RH2B-ULC
—
Top Bracket Mounting
RH2B-UT
—
With Diode (DC coil only)
RH2B-UD
RH2V2-UD
With Indicator and Diode (DC coil only)
RH2B-ULD
—
Basic
RH3B-U
RH3V2-U
With Indicator
RH3B-UL
RH3V2-UL
With Check Button
RH3B-UC
—
With Indicator and Check Button
RH3B-ULC
—
Top Bracket Mounting
RH3B-UT
—
With Diode (DC coil only)
RH3B-D*
RH3V2-D*
With Indicator and Diode (DC coil only)
RH3B-LD*
—
Basic
RH4B-U
RH4V2-U
With Indicator
RH4B-UL
RH4V2-UL
With Check Button
RH4B-UC
—
With Indicator and Check Button
RH4B-ULC
—
Top Bracket Mounting
RH4B-UT
—
With Diode (DC coil only)
RH4B-UD
RH4V2-UD
With Indicator and Diode (DC coil only)
RH4B-LD*
—
1. *Carries no UL recognition mark. 2. PCB terminal relays are designed to mount directly to a circuit board without any socket.
Circuit Breakers
Terminal Blocks
Timers
Relays & Sockets
SPDT
PCB Terminal
AC6V, AC12V, AC24V, AC110-120V, AC220-240V DC6V, DC12V, DC24V, DC48V, DC100-110V
DC6V, DC12V, DC24V, DC48V, DC100-110V
AC6V, AC12V, AC24V, AC110V, AC120V, AC220V, AC240V DC6V, DC12V, DC24V, DC48V, DC110V
DC6V, DC12V, DC24V, DC48V, DC110V
AC6V, AC12V, AC24V, AC110V, AC120V, AC220V, AC240V DC6V, DC12V, DC24V, DC48V, DC110V
DC6V, DC12V, DC24V, DC48V, DC110V
Ordering Information When ordering, specify the Part No. and coil voltage code: (example) RH3B-U Part No.
726
AC120V Coil Voltage Code
www.idec.com
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Relays & Sockets
RH Series
Sockets (for Blade Terminal Models) Standard DIN Rail Mount 1
Finger-safe DIN Rail Mount 1
Through Panel Mount
PCB Mount
RH1B
SH1B-05
SH1B-O5C
SH1B-51
SH1B-62
RH2B
SH2B-05
SH2B-05C
SH2B-51
SH2B-62
RH3B
SH3B-05
SH3B-05C
SH3B-51
SH3B-62
RH4B
SH4B-05
SH4B-05C
SH4B-51
SH4B-62
Switches & Pilot Lights
Relays
1. DIN Rail mount socket comes with two horseshoe clips. Do not use unless you plan to insert pullover wire spring. Replacement horseshoe clip part number is Y778-011.
Appearance
Description
Pullover Wire Spring
For DIN Mount Socket
RH1B
SY2S-02F1 2
RH2B
SY4S-02F1 2
RH3B
SH3B-05F1 2
RH4B
SH4B-02F1 2
RH1B, RH2B, RH3B, RH4B
SFA-202 3
For Through Panel & PCB Mount Socket
Min Order Qty
SY4S-51F1
2. Must use horseshoe clip when mounting in DIN mount socket. Replacement horseshoe clip part number is Y778-011. 3. Two required per relay.
10
Relays & Sockets
Leaf Spring (side latch)
Relay
Display Lights
Hold Down Springs & Clips
SFA-302 3 20
Leaf Spring (top latch)
RH1B, RH2B, RH3B, RH4B
SFA-101 3
SFA-301 3
AC Coil Ratings Rated Current (mA) ±15% at 20°C Voltage (V)
AC 50Hz SPDT
DPDT
3PDT
Coil Resistance (Ω) ±10% at 20°C
AC 60Hz 4PDT
SPDT
DPDT
3PDT
4PDT
SPDT
DPDT
3PDT
Operation Characteristics (against rated values at 20ºC) 4PDT
240
330
387
150
200
280
330
330
9.4
6.4
5.4
86
121
165
196
75
100
140
165
165
39.3
25.3
21.2
24
42
60.5
81
98
37
50
70
83
83
153
103
84.5
110
9.6
—
18.1
21.6
8.4
—
15.5
18.2
18.2
—
2,200
1,800
110-120
—
9.410.8
—
—
—
8.0-9.2
—
—
—
—
—
—
120
8.6
—
16.4
19.5
7.5
—
14.2
16.5
16.5
—
10,800
7,360
9.1
9.1
—
10,800
7,360
—
18,820
—
—
8.3
—
12,100
9,120
220
4.7
—
8.8
10.7
4.1
—
7.7
220-240
—
4.7-5.4
—
—
—
4.0-4.6
—
240
4.9
—
8.2
9.8
4.3
—
7.1
8.3
Dropout Voltage
110%
80% maximum
30% minimum
Terminal Blocks
170
Pickup Voltage
Timers
6 12
Max. Continuous Applied Voltage
DC Coil Ratings Voltage (V)
Coil Resistance (Ω) ±10% at 20°C
Rated Current (mA) ±15% at 20°C SPDT
DPDT
3PDT
4PDT
SPDT
DPDT
3PDT
Operation Characteristics (against rated values at 20ºC) 4PDT
128
150
240
250
47
40
25
24
64
75
120
125
188
160
100
96
24
32
36.9
60
62
750
650
400
388
48
18
18.5
30
31
2,660
2,600
1,600
1,550
100-110
—
8.2-9.0
—
—
—
12,250
—
—
110
8
—
12.8
15
13,800
—
8,600
7,340
USA: 800-262-IDEC
Pickup Voltage
Dropout Voltage
Circuit Breakers
6 12
Max. Continuous Applied Voltage
Standard coil voltages are in BOLD.
110%
80% maximum
Canada: 888-317-IDEC
10% minimum
727
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Relays & Sockets
RH Series UL Ratings
Switches & Pilot Lights
Contact Ratings
Model
Continuous Current
SPDT
DPDT 3PDT 4PDT
Display Lights
Resistive
Maximum Contact Capacity Allowable Contact Power
10A
Resistive Load
Inductive Load
1540VA 300W
990VA 210W
1650VA 300W
10A
1100VA 225W
Voltage
RH3
Ind. Load
RH1 RH2
240V AC
10A
Rated Load
RH2
RH4
RH3
RH4
RH1 RH2
RH3
RH4
7.5A
7.5A
7A
6.5A
5A
1/3 HP
1/3 HP
—
Res. Load
110 AC
10A
7A
120V AC
—
10A
10A
—
7.5A
7.5A
1/6 HP
1/6 HP
—
220 AC
7A
4.5A
30V DC
10A
10A
—
7A
—
—
—
—
—
28V DC
—
—
10A
—
—
—
—
—
—
30 DC
10A
7A
110 AC
10A
7.5A
220 AC
7.5A
5A
30 DC
10A
7.5A
RH3
CSA Ratings Resistive
Voltage
Horse Power Rating
General Use
RH1
RH2
RH3
RH4
RH1
RH2
RH3
RH4
RH1, 2, 3
240V AC
10A
10A
—
7.5A
7A
7A
7A
5A
1/3 HP
RH4
120V AC
10A
10A
10A
10A
7.5A
7.5A
—
7.5A
1/6 HP
30V DC
10A
10A
10A
10A
7A
7.5A
—
—
—
TÜV Ratings RH1
Horse Power Rating
Voltage (V)
Note: Inductive load for the rated load — cos ø = 0.3, L/R = 7 ms
Voltage
General Use RH1 RH2
240V AC
10A
10A
7.5A
7.5A
30V DC
10A
10A
10A
10A
Timers
Relays & Sockets
AC: cos ø = 1.0, DC: L/R = 0 ms
Socket Specifications Sockets DIN Rail Mount Sockets
Finger-safe DIN Rail Mount Through Panel Mount Socket
Circuit Breakers
Terminal Blocks
PCB Mount Socket
Terminal
Electrical Rating
Wire Size
Torque
SH1B-05
(Coil) M3 screws (contact) M3.5 screws with captive wire clamp
250V, 10A
Maximum up to 2–#12AWG
5.5 - 9 in•lbs 9 - 11.5 in•lbs
SH2B-05 SH3B-05 SH4B-05
M3.5 screws with captive wire clamp
300V, 10A
Maximum up to 2–#12AWG
9 - 11.5 in•lbs
SH1B-05C
(coil) M3 screws 250V, 10A (contact) M3.5 screws with captive wire clamp, fingersafe
Maximum up to 2–#12AWG
5.5 - 9 in•lbs 9 - 11.5 in•lbs
SH2B-05C SH3B-05C SH4B-05C
M3.5 screws with captive wire clamp, fingersafe
300V, 10A
Maximum up to 2–#12AWG
9 - 11.5 in•lbs
SH1B-51 SH2B-51 SH3B-51 SH4B-51
Solder
300V, 10A
—
—
SH1B-62
PCB mount
250V, 10A
—
—
SH2B-62 SH3B-62 SH4B-62
PCB mount
300V, 10A
—
—
Accessories Description
Use with
Part No.
Remarks
Aluminum DIN Rail (1 meter length)
All DIN rail sockets
BNDN1000
IDEC offers a low-profile DIN rail (BNDN1000). The BNDN1000 is designed to accommodate DIN mount sockets. Made of durable extruded aluminum, the BNDN1000 measures 0.413 (10.5mm) in height and 1.37 (35mm) in width (DIN standard). Standard length is 39” (1,000mm).
DIN Rail End Stop
DIN rail
BNL5
9.1 mm wide.
Replacement Hold-Down Spring Anchor
DIN mount sockets and hold down springs.
Y778-011
For use on DIN rail mount socket when using pullover wire hold down spring. 2 pieces included with each socket.
728
Appearance
www.idec.com
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Relays & Sockets
RH Series
Specifications Silver cadmium oxide
Contact Resistance 1
50mΩ maximum
Minimum Applicable Load
24V DC, 30 mA; 5V DC, 100 mA (reference value)
Operate Time 2
Release Time 2
20ms maximum
3PDT 4PDT
25ms maximum
SPDT DPDT
20ms maximum
3PDT 4PDT
25ms maximum
SPDT
AC: 1.1VA (50Hz), 1VA (60Hz)
DC: 0.8W
DPDT
AC: 1.4VA (50Hz), 1.2VA (60Hz)
DC: 0.9W
3PDT
AC: 2VA (50Hz), 1.7VA (60Hz)
DC: 1.5W
4PDT
AC: 2.5VA (50Hz), 2VA (60Hz)
DC: 1.5W
Insulation Resistance
3
100MΩ minimum (500V DC megger)
SPDT
Between live and dead parts: 2,000V AC, 1 minute Between contact and coil: 2,000V AC, 1 minute Between contacts of the same pole: 1,000V AC, 1 minute
DPDT 3PDT 4PDT
Between live and dead parts: Between contact and coil: Between contacts of different poles: Between contacts of the same pole:
2,000V AC, 1 minute 2,000V AC, 1 minute 2,000V AC, 1 minute 1,000V AC, 1 minute
Electrical: Mechanical:
1,800 operations/hour maximum 18,000 operations/hour maximum
Vibration Resistance
Damage limits: Operating extremes:
10 to 55Hz, amplitude 0.5 mm 10 to 55Hz, amplitude 0.5 mm
Shock Resistance
Damage limits: Operating extremes:
1,000m/s2 (100G) 200m/s2 (20G - SPDT, DPDT) 100m/s2 (10G - 3PDT, 4PDT)
Mechanical Life
50,000,000 operations minimum
Operating Temperature 4
500,000 operations minimum (120V AC, 10A)
SPDT 3PDT 4PDT
200,000 operations minimum (120V AC, 10A)
SPDT
–25 to +50°C (no freezing)
DPDT 3PDT 4PDT
–25 to +40°C (no freezing)
Operating Humidity
45 to 85% RH (no condensation)
Weight (approx.)
SPDT: 24g, DPDT: 37g, 3PDT: 50g, 4PDT: 74g
Terminal Blocks
DPDT
Timers
Operating Frequency
Electrical Life
Relays & Sockets
Dielectric Strength
Display Lights
Power Consumption (approx.)
SPDT DPDT
Switches & Pilot Lights
Contact Material
Note: Above values are initial values. 1. Measured using 5V DC, 1A voltage drop method 2. Measured at the rated voltage (at 20°C), excluding contact bouncing Release time of relays with diode: 40 ms maximum 3. Relays with indicator or diode: 1000V AC, 1 minute 4. For use under different temperature conditions, refer to Continuous Load Current vs. Operating Temperature Curve. The operating temperature range of relays with indicator or diode is –25 to +40°C.
Circuit Breakers
USA: 800-262-IDEC
Canada: 888-317-IDEC
729
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Relays & Sockets
RH Series
Electrical Life Curves AC Load
DC Load 1000
1000
(RH1)
120V AC resistive
(RH1)
500 Life (× 10,000 operations)
Life (× 10,000 operations)
500
100
50
Display Lights
Switches & Pilot Lights
Characteristics (Reference Data)
30V DC resistive 100
50 100V DC resistive 30V DC inductive
20
240V AC inductive
10
1
2
3
(RH2) 1000
20 240V AC resistive
120V AC inductive 4
5 6 7 Load Current (A)
8
9
100V DC inductive 10
10
1
2
3
4 5 6 Load Current (A)
7
8
9
10
7
8
9
10
7
8
9
10
(RH2) 1000
120V AC resistive
30V DC resistive 500 Life (× 10,000 operations)
Relays & Sockets
Life (× 10,000 operations)
500
100
50
100
50
240V AC resistive 120V AC inductive
240V AC inductive
100V DC resistive 100V DC inductive
20
20
10
1
2
3
4
5 6 7 Load Current (A)
8
9
10
10
1
120V AC resistive
Life (× 10,000 operations)
Life (× 10,000 operations)
Timers Terminal Blocks
3
4 5 6 Load Current (A)
30V DC resistive
500
500
100
50
30V DC inductive
100
50
20
240V AC inductive 240V AC resistive 120V AC inductive
10
2
(RH3/RH4) 1000
(RH3/RH4) 1000
20
30V DC inductive
1
2
3
4 5 6 Load Current (A)
7
8
9
100V DC resistive 100V DC inductive
10
10
1
2
3
4 5 6 Load Current (A)
Maximum Switching Capacity (RH1)
(RH2/RH3/RH4)
10.0
10.0 AC resistive
AC resistive 5.0
AC inductive
Load Current (A)
Circuit Breakers
Load Current (A)
5.0
DC resistive 1.0
DC inductive
0.5
0.1 1
5
10
DC resistive 1.0 DC inductive 0.5
50
100
0.1 1
200 300
Load Voltage (V)
730
AC inductive
5
10 50 Load Voltage (V)
100
200 300
www.idec.com
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Relays & Sockets
RH Series
Continuous Load Current vs. Operating Temperature Curve (Basic Type, With Check Button, and Top Bracket Mounting Type) Note: The rated voltage is applied to the coil.
100
(RH2)
90
DC Coil
70 60 AC Coil
50 40 30 20 10
Operating Temperature (oC)
80
80 DC Coil
70 60 50
AC Coil
40 30 20
0
70 60 50
AC/DC Coil
40 30 20
0
1 2 3 4 5 6 7 8 9 10 Load Current (A)
1 2 3 4 5 6 7 8 9 10 Load Current (A)
Display Lights
1 2 3 4 5 6 7 8 9 10 Load Current (A)
80
10
10
0
Note: The rated voltage is applied to the coil.
100
90 Operating Temperature (oC)
Operating Temperature (oC)
90
(RH3/RH4)
Note: The rated voltage is applied to the coil.
100
Switches & Pilot Lights
(RH1)
Internal Connection (View from Bottom) Basic Type SPDT
DPDT
1
1
5 9
4
1
5
8
5
9
12
9
13( – )
14 (+)
( + )14
2
4PDT
With Check Button
4
1
6
8
5
6
7
8
10
12
9
10
11
12
13 ( – )
2
3
Contacts can be operated by pressing the check button.
( + )14
13( – )
( + )14
Front Pushbutton
4
Relays & Sockets
13 (–)
3PDT
With Indicator (-L type) SPDT
Below 100V AC/DC
3PDT 1
2
4
1
2
3
4
5
5
6
8
5
6
7
8
9
10
12
9
10
11
12
13 (–)
14 (+)
13 ( – )
( + )14
13( – )
( + )14
1
1
2
4
1
2
3
4
5
5
6
8
5
6
7
8
9
9
10
12
9
10
11
12
14 (+)
13( – )
( + )14
13( – )
1
Below 24V AC/DC
8
9
12
13( – )
1
24V AC/DC and over
( + )14
4
5
( + )14
4
5
8
9
12
13( – )
( + )14
When the relay is energized, the indicator goes on. • Relay coils less than 100V DC do not contain a protection diode (except DPDT). • Relay coils below 100V use LED indicator, coils above 100V use neon lamp indicator.
Timers
13 (–)
DPDT
1 9
100V AC/DC and over
4PDT
With Diode (-D type)
13 (–)
DPDT
1
1
5 9 14 (+)
3PDT 4
1
5
8
5
9
12
9
13( – )
( + )14
13 ( – )
4PDT 4
1
6
8
5
6
7
8
10
12
9
10
11
12
( + )14
13( – )
2
2
3
4
( + )14
Contains a diode to absorb the back emf generated when the coil is de-energized. The release time is slightly longer. Available for DC coil only. • Diode Characteristics Reverse withstand voltage: 1,000V Forward current: 1A
Terminal Blocks
SPDT
Circuit Breakers
USA: 800-262-IDEC
Canada: 888-317-IDEC
731
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Relays & Sockets
RH Series
Display Lights
Switches & Pilot Lights
With Indicator LED & Diode (-LD type) SPDT
3PDT
4PDT
DPDT
1
Below 100V DC
1
2
4
1
2
3
4
9
5
6
8
5
6
7
8
9
10
12
9
10
11
12
13 (–)
14 (+)
13( – )
( + )14
13( – )
( + )14
Below 24V AC/DC
4
5
8
9
12 ( + )14
13( – )
Contains an LED indicator and a surge absorber, and has the same height as the basic type.
1
1
2
4
1
2
3
4
1
5
5
6
8
5
6
7
8
5
8
9
10
12
9
10
11
12
9
12
9
100V DC and over
1
5
14( + )
13 ( – )
13( – )
( + )14
13( – )
24V AC/DC and over
( + )14
4
13 (–)
14 (+)
Dimensions (mm) RH2B-U/RH2B-UL/RH2B-UD/RH2B-ULD
Total length from panel surface including relay socket SH3B-05: 61.5 (63.5) max., SH3B-51: 39.6 (41.6) max.
Dimensions in the ( ) include a hold-down spring.
Dimensions in the ( ) include a hold-down spring.
ø2.6 hole
4.7
4.7
Dimensions in the ( ) include a hold-down spring.
ø2.6 hole
1 4
5
8
9
12
13
14
13 14
6.4
0.5
35.6 max.
6.4
21
8
10
11
14
6.4
RH1B-UT
31
RH2B-UT
Dimensions in the ( ) include a hold-down spring.
ø2.6 hole
4.7
ø2.6 hole
0.5
10
4.7
Total length from panel surface including relay socket SH4B-05: 61.5 (63.5) max., SH4B-51: 39.6 (41.6) max.
4.7
Timers
RH4B-U/RH4B-UL/RH4B-UD/RH4B-LD
6
9 13
35.6 max.
4
5
1 1
3.5 14.5 2
3
5
6
7
8
9
10
11
12
13
2 35.6 max.
5.4 6.4
2 21.5
35.6 max.
12
13
14
6.4
14
6.4
41
RH4B-UT
ø2.6 hole 4 8
10
12 14
2
3
6
7
8
9
10
11
12
31.5
732
35.6 max.
6.4
35.6 max.
6.4
7.25
2
7.25
13
21.5
42 max.
4
5
28
1
6
9
5.9
2
5
44 38
43.2 38
5.9
1
13
3.5 0.5 4.7
2
28
ø2.6 hole
0.5 4.7
3.5
4.7
10
10
4.7 10 10
10
RH3B-UT Circuit Breakers
3.5
4
8
9
27.5
0.5
1
35.6 max.
5.9
6.6
Terminal Blocks
ø2.6 hole
4
5
7.25
13 14
4.7
9
43.2 38
27.5
43.2 38
5.9
5
27.5
35.6 max.
2
1
14
4.7
5.4
27.5
0.5
1
0.5
27.5
5
9
0.5
ø2.6 hole
RH3B-U/RH3B-UL/RH3B-D/RH3B-LD
Total length from panel surface including relay socket SH2B-05: 61.5 (63.5) max., SH2B-51: 39.6 (41.6) max.
4.7
Relays & Sockets
Total length from panel surface including relay socket SH1B-05: 61.5 (63.5) max., SH1B-51: 39.6 (41.6) max.
27.5
RH1B-U/RH1B-UL/RH1B-UD/RH1B-ULD
14
28 41.5
www.idec.com
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Relays & Sockets
RH Series Dimensions con’t (mm) Switches & Pilot Lights
RH1V2-U/RH1V2-UD
RH2V2-U/RH2V2-UL/RH2V2-UD 8-ø2.4 holes 4.7
0.5
3-ø2.4 holes
7.25
0.5
14
12 14
35.6 max.
4.4
7.8
10
RH3V2-U/RH3V2-UL/RH3V2-D
21
4.6
14.2
RH4V2-U/RH4V2-UL/RH4V2-UD 10 10
14-ø2.4 holes
2
4.7
10
13.15
4
7
8
10
11
12 14
0.5
4.6
7.8
3
6
9 13
7.25
31
2
5
7.25
14
13
27.5
1
0.5
11
27.5
8
10
7.8
4
6
9
0.5 35.6 max.
2
5
13.15
2 0.5
1
Display Lights
30
11-ø2.4 holes
4.7
4.6
8
9
2
35.6 max.
4
5
13
27.5
1
5
14
12.5
0.5
9
6.6
27.5
5
13
13.15
1
0.5
7.15
2
4.7
2
1.5
2-ø2 holes 0.5
41
35.6 max.
4.6
Relays & Sockets
Standard DIN Rail Mount Sockets SH1B-05
SH2B-05 31.5
22 DIN Rail (BNDN)
18
M3.5 Terminal Screw
Terminal Arrangement 2-ø4.2 Mounting Holes (or M4 Tapped Holes)
47
(Top View) ø3.2 min.
ø3.6 min. 7.9 max.
5.9 max.
SH3B-05
14
13
12
14.5
9
30
25
(Top View)
7.9 max. ø3.6 min.
5
4
2
1
5.5 min.
14 12
M3.5 Terminal Screw
18
Terminal Arrangement 2-ø4.2 Mounting Holes (or M4 Tapped Holes)
5.5 min.
9
46
7.9 max.
50
7 3
6
5
2
1
11
10
14 12
(Top View) ø3.6 min.
8 4
46 4.4 max.
13 10
DIN Rail (BNDN)
47
6
67
47
8
36 4.4 max.
25
8
Terminal Arrangement 2-ø4.2 Mounting Holes (or M4 Tapped Holes)
14.5
31.5
42 DIN Rail (BNDN)
Terminal Blocks
67
26
4.2
18
4.2
M3.5 Terminal Screw
2.5
8
2.5
5.5 min.
SH4B-05 31.5
32
40
5 1
(For terminals 13 and 14)
(For terminals 1, 5, and 9)
36
8 4
26 4.4 max.
13
25
20
Terminal Arrangement 2-ø4.2 Mounting Holes (or M4 Tapped Holes)
9
4 max.
14.5
DIN Rail (BNDN)
18
Timers
2.5
67
4.4 max.
14
2.5
67
4.2
1
4.8 min.
5.5 min.
16
M3.5 Terminal Screw
5
16
M3 Terminal Screw
31.5
8
47
8
4.2
17
14.5 25
13
9
(Top View) 7.9 max. ø3.6 min.
Circuit Breakers
USA: 800-262-IDEC
Canada: 888-317-IDEC
733
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Relays & Sockets
RH Series
Finger-safe DIN Rail Mount Sockets SH1B-05C
SH2B-05C 36
22
17
36
M3.5 Terminal Screw
7
DIN Rail (BNDN)
Terminal Arrangement
ø5
1
Terminal Arrangement 2-ø4.2 Mounting Holes (or M4 Tapped Holes)
48
69
4.2
DIN Rail (BNDN)
ø5
5
2-ø4.2 Mounting Holes (or M4 Tapped Holes)
25
8
5
4
1
14
13
12
9
49
25
4.2
M3.5 Terminal Screw
7
69
Switches & Pilot Lights
Dimensions con’t (mm)
26
16 M3 Terminal Screw
14
13
18.7
20
(Top View)
29.5
(Top View)
29.5
SH3B-05C 7
M3.5 Terminal Screw
36 25
2-ø4.2 Mounting Holes (or M4 Tapped Holes)
6
5
4
2
1
DIN Rail (BNDN)
49
69
14 12
9
7 3
6
5
2
1
11
10
14 12
Ring terminals cannot be used.
18.7
46
1.7
29.5
40
8 4
46
13 10
(Top View)
Ring terminals cannot be used.
18.7
36
Terminal Arrangement 2-ø4.2 Mounting Holes (or M4 Tapped Holes)
ø5
4.2
4.2
8
25
7
Terminal Arrangement
36
1.7
36
42 DIN Rail (BNDN)
49
32
SH4B-05C
ø5
13
9
(Top View)
29.5
50
Through Panel Mount Socket SH2B-51
25.6 +0.2 0
11 18.7
3
27
N: No. of sockets mounted
0.3
0.3
(Bottom View)
5.4 min.∗
Timers
3
+0.5 0
1 4 5 8 9 12 13 14
13 14 18
[27 (N–1) + 21.4]
Terminal Arrangement
(Bottom View)
11 18.7
5.4 min.∗
1 5 9
25.4
31
Panel Thickness: 1 to 2
+0.2 0
[18 (N–1) +
Terminal Arrangement
31
Panel Thickness: 1 to 2
12.4] +0.5 0
25.6
SH1B-51
25.4
Relays & Sockets
Ring terminals cannot be used.
18.7
26 30
69
Display Lights
1.7
16
1.7
9
Ring terminals cannot be used.
N: No. of sockets mounted
∗ 10.4 min. when using hold-down springs
3.5
3.5
∗ 10.4 min. when using hold-down springs
2.4
21.2
12.2
SH4B-51
11 18.7
31
25.4
1 2 3 4 5 6 7 8 9 10 11 12
45
N: No. of sockets mounted
3 11 18.7
+0.2 0
+0.2 0
[45 (N–1) + 39.4] +0.5 0
Terminal Arrangement
13
14
(Bottom View)
0.3
0.3
3
25.6
1 2 4 5 6 8 9 10 12 13
36
Panel Thickness: 1 to 2
25.6
[36 (N–1) +
Terminal Arrangement
5.4 min.∗
25.4
31
Terminal Blocks
Panel Thickness: 1 to 2
30.4] +0.5 0
14
(Bottom View)
5.4 min.∗
SH3B-51
N: No. of sockets mounted
∗ 10.4 min. when using hold-down springs
3.5
3.5 39.2
Circuit Breakers
30.2
∗ 10.4 min. when using hold-down springs
734
www.idec.com
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Relays & Sockets
RH Series Dimensions con’t (mm) Switches & Pilot Lights
PCB Mount Sockets SH2B-62
15
(Bottom View)
15
(Tolerance p0.1)
5.65
10
2
8-ø2.4 holes
(Tolerance ±0.1)
∗ 34 min. when using hold-down springs
Display Lights
6.85
1 2 3 4 5 6 7 8 9 10 11 12
45
3
(Bottom View)
31 min.∗
6.6
15
11-ø2.4 holes 2
(Tolerance ±0.1)
∗ 36 min. when using hold-down springs
14-ø2.4 holes (Tolerance ±0.1)
Relays & Sockets
∗ 36 min. when using hold-down springs
10 10 10
14
11
39.2
45 min. 31.3
12.5
25.4
14
(Bottom View)
Terminal Arrangement
13
31 min.∗
2
31
4.7
10 10
11 15
21.3
0.3
0.3
13
3
36
7.35
12.5 6.65
25.4
31
1 2 4 5 6 8 9 10 12
4.7 6.65
SH4B-62 36 min.
Terminal Arrangement
6.6
SH3B-62
30.2
25.4
2-ø2 holes
15.5
14
11
36 min. when using hold-down springs
12.2
3
21.5 min.
2.85
6.6
31 min.
2 1.5
21.2
0.3
(Bottom View)
11
1 4 5 8 9 12 13
5.95
3
Terminal Arrangement
18 min. 4.4
11.85
0.3
13 14
18
6.8
29
1 5 9
4.7
3-ø2.4 holes 4.7 6.95
31
25.4
Terminal Arrangement
29 min.∗ 12.5
SH1B-62
Timers Terminal Blocks Circuit Breakers
USA: 800-262-IDEC