Preview only show first 10 pages with watermark. For full document please download

Relays & Sockets Rh Series Spdt Through 4pdt, 10a Contacts

   EMBED


Share

Transcript

Relays & Sockets RH Series Display Lights Switches & Pilot Lights RH Series Compact Power Relays SPDT through 4PDT, 10A contacts Compact power type relays The RH series are miniature power relays with a large capacity. The RH relays feature 10A contact capacity as large as the RR series but in a miniature package. The compact size saves space. Part Number Selection Part Number Contact Blade Terminal Model Basic DPDT 3PDT 4PDT RH1B-U Coil Voltage Code (Standard Stock in bold) RH1V2-U With Indicator RH1B-UL — With Check Button RH1B-UC — With Indicator and Check Button RH1B-ULC — Top Bracket Mounting RH1B-UT — With Diode (DC coil only) RH1B-UD RH1V2-UD DC6V, DC12V, DC24V, DC48V, DC110V DC12V, DC24V, DC48V, DC110V AC6V, AC12V, AC24V, AC110V, AC120V, AC220V, AC240V DC6V, DC12V, DC24V, DC48V, DC110V With Indicator and Diode (DC coil only) RH1B-ULD — Basic RH2B-U RH2V2-U With Indicator RH2B-UL RH2V2-UL With Check Button RH2B-UC — With Indicator and Check Button RH2B-ULC — Top Bracket Mounting RH2B-UT — With Diode (DC coil only) RH2B-UD RH2V2-UD With Indicator and Diode (DC coil only) RH2B-ULD — Basic RH3B-U RH3V2-U With Indicator RH3B-UL RH3V2-UL With Check Button RH3B-UC — With Indicator and Check Button RH3B-ULC — Top Bracket Mounting RH3B-UT — With Diode (DC coil only) RH3B-D* RH3V2-D* With Indicator and Diode (DC coil only) RH3B-LD* — Basic RH4B-U RH4V2-U With Indicator RH4B-UL RH4V2-UL With Check Button RH4B-UC — With Indicator and Check Button RH4B-ULC — Top Bracket Mounting RH4B-UT — With Diode (DC coil only) RH4B-UD RH4V2-UD With Indicator and Diode (DC coil only) RH4B-LD* — 1. *Carries no UL recognition mark. 2. PCB terminal relays are designed to mount directly to a circuit board without any socket. Circuit Breakers Terminal Blocks Timers Relays & Sockets SPDT PCB Terminal AC6V, AC12V, AC24V, AC110-120V, AC220-240V DC6V, DC12V, DC24V, DC48V, DC100-110V DC6V, DC12V, DC24V, DC48V, DC100-110V AC6V, AC12V, AC24V, AC110V, AC120V, AC220V, AC240V DC6V, DC12V, DC24V, DC48V, DC110V DC6V, DC12V, DC24V, DC48V, DC110V AC6V, AC12V, AC24V, AC110V, AC120V, AC220V, AC240V DC6V, DC12V, DC24V, DC48V, DC110V DC6V, DC12V, DC24V, DC48V, DC110V Ordering Information When ordering, specify the Part No. and coil voltage code: (example) RH3B-U Part No. 726 AC120V Coil Voltage Code www.idec.com Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Relays & Sockets RH Series Sockets (for Blade Terminal Models) Standard DIN Rail Mount 1 Finger-safe DIN Rail Mount 1 Through Panel Mount PCB Mount RH1B SH1B-05 SH1B-O5C SH1B-51 SH1B-62 RH2B SH2B-05 SH2B-05C SH2B-51 SH2B-62 RH3B SH3B-05 SH3B-05C SH3B-51 SH3B-62 RH4B SH4B-05 SH4B-05C SH4B-51 SH4B-62 Switches & Pilot Lights Relays 1. DIN Rail mount socket comes with two horseshoe clips. Do not use unless you plan to insert pullover wire spring. Replacement horseshoe clip part number is Y778-011. Appearance Description Pullover Wire Spring For DIN Mount Socket RH1B SY2S-02F1 2 RH2B SY4S-02F1 2 RH3B SH3B-05F1 2 RH4B SH4B-02F1 2 RH1B, RH2B, RH3B, RH4B SFA-202 3 For Through Panel & PCB Mount Socket Min Order Qty SY4S-51F1 2. Must use horseshoe clip when mounting in DIN mount socket. Replacement horseshoe clip part number is Y778-011. 3. Two required per relay. 10 Relays & Sockets Leaf Spring (side latch) Relay Display Lights Hold Down Springs & Clips SFA-302 3 20 Leaf Spring (top latch) RH1B, RH2B, RH3B, RH4B SFA-101 3 SFA-301 3 AC Coil Ratings Rated Current (mA) ±15% at 20°C Voltage (V) AC 50Hz SPDT DPDT 3PDT Coil Resistance (Ω) ±10% at 20°C AC 60Hz 4PDT SPDT DPDT 3PDT 4PDT SPDT DPDT 3PDT Operation Characteristics (against rated values at 20ºC) 4PDT 240 330 387 150 200 280 330 330 9.4 6.4 5.4 86 121 165 196 75 100 140 165 165 39.3 25.3 21.2 24 42 60.5 81 98 37 50 70 83 83 153 103 84.5 110 9.6 — 18.1 21.6 8.4 — 15.5 18.2 18.2 — 2,200 1,800 110-120 — 9.410.8 — — — 8.0-9.2 — — — — — — 120 8.6 — 16.4 19.5 7.5 — 14.2 16.5 16.5 — 10,800 7,360 9.1 9.1 — 10,800 7,360 — 18,820 — — 8.3 — 12,100 9,120 220 4.7 — 8.8 10.7 4.1 — 7.7 220-240 — 4.7-5.4 — — — 4.0-4.6 — 240 4.9 — 8.2 9.8 4.3 — 7.1 8.3 Dropout Voltage 110% 80% maximum 30% minimum Terminal Blocks 170 Pickup Voltage Timers 6 12 Max. Continuous Applied Voltage DC Coil Ratings Voltage (V) Coil Resistance (Ω) ±10% at 20°C Rated Current (mA) ±15% at 20°C SPDT DPDT 3PDT 4PDT SPDT DPDT 3PDT Operation Characteristics (against rated values at 20ºC) 4PDT 128 150 240 250 47 40 25 24 64 75 120 125 188 160 100 96 24 32 36.9 60 62 750 650 400 388 48 18 18.5 30 31 2,660 2,600 1,600 1,550 100-110 — 8.2-9.0 — — — 12,250 — — 110 8 — 12.8 15 13,800 — 8,600 7,340 USA: 800-262-IDEC Pickup Voltage Dropout Voltage Circuit Breakers 6 12 Max. Continuous Applied Voltage Standard coil voltages are in BOLD. 110% 80% maximum Canada: 888-317-IDEC 10% minimum 727 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Relays & Sockets RH Series UL Ratings Switches & Pilot Lights Contact Ratings Model Continuous Current SPDT DPDT 3PDT 4PDT Display Lights Resistive Maximum Contact Capacity Allowable Contact Power 10A Resistive Load Inductive Load 1540VA 300W 990VA 210W 1650VA 300W 10A 1100VA 225W Voltage RH3 Ind. Load RH1 RH2 240V AC 10A Rated Load RH2 RH4 RH3 RH4 RH1 RH2 RH3 RH4 7.5A 7.5A 7A 6.5A 5A 1/3 HP 1/3 HP — Res. Load 110 AC 10A 7A 120V AC — 10A 10A — 7.5A 7.5A 1/6 HP 1/6 HP — 220 AC 7A 4.5A 30V DC 10A 10A — 7A — — — — — 28V DC — — 10A — — — — — — 30 DC 10A 7A 110 AC 10A 7.5A 220 AC 7.5A 5A 30 DC 10A 7.5A RH3 CSA Ratings Resistive Voltage Horse Power Rating General Use RH1 RH2 RH3 RH4 RH1 RH2 RH3 RH4 RH1, 2, 3 240V AC 10A 10A — 7.5A 7A 7A 7A 5A 1/3 HP RH4 120V AC 10A 10A 10A 10A 7.5A 7.5A — 7.5A 1/6 HP 30V DC 10A 10A 10A 10A 7A 7.5A — — — TÜV Ratings RH1 Horse Power Rating Voltage (V) Note: Inductive load for the rated load — cos ø = 0.3, L/R = 7 ms Voltage General Use RH1 RH2 240V AC 10A 10A 7.5A 7.5A 30V DC 10A 10A 10A 10A Timers Relays & Sockets AC: cos ø = 1.0, DC: L/R = 0 ms Socket Specifications Sockets DIN Rail Mount Sockets Finger-safe DIN Rail Mount Through Panel Mount Socket Circuit Breakers Terminal Blocks PCB Mount Socket Terminal Electrical Rating Wire Size Torque SH1B-05 (Coil) M3 screws (contact) M3.5 screws with captive wire clamp 250V, 10A Maximum up to 2–#12AWG 5.5 - 9 in•lbs 9 - 11.5 in•lbs SH2B-05 SH3B-05 SH4B-05 M3.5 screws with captive wire clamp 300V, 10A Maximum up to 2–#12AWG 9 - 11.5 in•lbs SH1B-05C (coil) M3 screws 250V, 10A (contact) M3.5 screws with captive wire clamp, fingersafe Maximum up to 2–#12AWG 5.5 - 9 in•lbs 9 - 11.5 in•lbs SH2B-05C SH3B-05C SH4B-05C M3.5 screws with captive wire clamp, fingersafe 300V, 10A Maximum up to 2–#12AWG 9 - 11.5 in•lbs SH1B-51 SH2B-51 SH3B-51 SH4B-51 Solder 300V, 10A — — SH1B-62 PCB mount 250V, 10A — — SH2B-62 SH3B-62 SH4B-62 PCB mount 300V, 10A — — Accessories Description Use with Part No. Remarks Aluminum DIN Rail (1 meter length) All DIN rail sockets BNDN1000 IDEC offers a low-profile DIN rail (BNDN1000). The BNDN1000 is designed to accommodate DIN mount sockets. Made of durable extruded aluminum, the BNDN1000 measures 0.413 (10.5mm) in height and 1.37 (35mm) in width (DIN standard). Standard length is 39” (1,000mm). DIN Rail End Stop DIN rail BNL5 9.1 mm wide. Replacement Hold-Down Spring Anchor DIN mount sockets and hold down springs. Y778-011 For use on DIN rail mount socket when using pullover wire hold down spring. 2 pieces included with each socket. 728 Appearance www.idec.com Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Relays & Sockets RH Series Specifications Silver cadmium oxide Contact Resistance 1 50mΩ maximum Minimum Applicable Load 24V DC, 30 mA; 5V DC, 100 mA (reference value) Operate Time 2 Release Time 2 20ms maximum 3PDT 4PDT 25ms maximum SPDT DPDT 20ms maximum 3PDT 4PDT 25ms maximum SPDT AC: 1.1VA (50Hz), 1VA (60Hz) DC: 0.8W DPDT AC: 1.4VA (50Hz), 1.2VA (60Hz) DC: 0.9W 3PDT AC: 2VA (50Hz), 1.7VA (60Hz) DC: 1.5W 4PDT AC: 2.5VA (50Hz), 2VA (60Hz) DC: 1.5W Insulation Resistance 3 100MΩ minimum (500V DC megger) SPDT Between live and dead parts: 2,000V AC, 1 minute Between contact and coil: 2,000V AC, 1 minute Between contacts of the same pole: 1,000V AC, 1 minute DPDT 3PDT 4PDT Between live and dead parts: Between contact and coil: Between contacts of different poles: Between contacts of the same pole: 2,000V AC, 1 minute 2,000V AC, 1 minute 2,000V AC, 1 minute 1,000V AC, 1 minute Electrical: Mechanical: 1,800 operations/hour maximum 18,000 operations/hour maximum Vibration Resistance Damage limits: Operating extremes: 10 to 55Hz, amplitude 0.5 mm 10 to 55Hz, amplitude 0.5 mm Shock Resistance Damage limits: Operating extremes: 1,000m/s2 (100G) 200m/s2 (20G - SPDT, DPDT) 100m/s2 (10G - 3PDT, 4PDT) Mechanical Life 50,000,000 operations minimum Operating Temperature 4 500,000 operations minimum (120V AC, 10A) SPDT 3PDT 4PDT 200,000 operations minimum (120V AC, 10A) SPDT –25 to +50°C (no freezing) DPDT 3PDT 4PDT –25 to +40°C (no freezing) Operating Humidity 45 to 85% RH (no condensation) Weight (approx.) SPDT: 24g, DPDT: 37g, 3PDT: 50g, 4PDT: 74g Terminal Blocks DPDT Timers Operating Frequency Electrical Life Relays & Sockets Dielectric Strength Display Lights Power Consumption (approx.) SPDT DPDT Switches & Pilot Lights Contact Material Note: Above values are initial values. 1. Measured using 5V DC, 1A voltage drop method 2. Measured at the rated voltage (at 20°C), excluding contact bouncing Release time of relays with diode: 40 ms maximum 3. Relays with indicator or diode: 1000V AC, 1 minute 4. For use under different temperature conditions, refer to Continuous Load Current vs. Operating Temperature Curve. The operating temperature range of relays with indicator or diode is –25 to +40°C. Circuit Breakers USA: 800-262-IDEC Canada: 888-317-IDEC 729 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Relays & Sockets RH Series Electrical Life Curves AC Load DC Load 1000 1000 (RH1) 120V AC resistive (RH1) 500 Life (× 10,000 operations) Life (× 10,000 operations) 500 100 50 Display Lights Switches & Pilot Lights Characteristics (Reference Data) 30V DC resistive 100 50 100V DC resistive 30V DC inductive 20 240V AC inductive 10 1 2 3 (RH2) 1000 20 240V AC resistive 120V AC inductive 4 5 6 7 Load Current (A) 8 9 100V DC inductive 10 10 1 2 3 4 5 6 Load Current (A) 7 8 9 10 7 8 9 10 7 8 9 10 (RH2) 1000 120V AC resistive 30V DC resistive 500 Life (× 10,000 operations) Relays & Sockets Life (× 10,000 operations) 500 100 50 100 50 240V AC resistive 120V AC inductive 240V AC inductive 100V DC resistive 100V DC inductive 20 20 10 1 2 3 4 5 6 7 Load Current (A) 8 9 10 10 1 120V AC resistive Life (× 10,000 operations) Life (× 10,000 operations) Timers Terminal Blocks 3 4 5 6 Load Current (A) 30V DC resistive 500 500 100 50 30V DC inductive 100 50 20 240V AC inductive 240V AC resistive 120V AC inductive 10 2 (RH3/RH4) 1000 (RH3/RH4) 1000 20 30V DC inductive 1 2 3 4 5 6 Load Current (A) 7 8 9 100V DC resistive 100V DC inductive 10 10 1 2 3 4 5 6 Load Current (A) Maximum Switching Capacity (RH1) (RH2/RH3/RH4) 10.0 10.0 AC resistive AC resistive 5.0 AC inductive Load Current (A) Circuit Breakers Load Current (A) 5.0 DC resistive 1.0 DC inductive 0.5 0.1 1 5 10 DC resistive 1.0 DC inductive 0.5 50 100 0.1 1 200 300 Load Voltage (V) 730 AC inductive 5 10 50 Load Voltage (V) 100 200 300 www.idec.com Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Relays & Sockets RH Series Continuous Load Current vs. Operating Temperature Curve (Basic Type, With Check Button, and Top Bracket Mounting Type) Note: The rated voltage is applied to the coil. 100 (RH2) 90 DC Coil 70 60 AC Coil 50 40 30 20 10 Operating Temperature (oC) 80 80 DC Coil 70 60 50 AC Coil 40 30 20 0 70 60 50 AC/DC Coil 40 30 20 0 1 2 3 4 5 6 7 8 9 10 Load Current (A) 1 2 3 4 5 6 7 8 9 10 Load Current (A) Display Lights 1 2 3 4 5 6 7 8 9 10 Load Current (A) 80 10 10 0 Note: The rated voltage is applied to the coil. 100 90 Operating Temperature (oC) Operating Temperature (oC) 90 (RH3/RH4) Note: The rated voltage is applied to the coil. 100 Switches & Pilot Lights (RH1) Internal Connection (View from Bottom) Basic Type SPDT DPDT 1 1 5 9 4 1 5 8 5 9 12 9 13( – ) 14 (+) ( + )14 2 4PDT With Check Button 4 1 6 8 5 6 7 8 10 12 9 10 11 12 13 ( – ) 2 3 Contacts can be operated by pressing the check button. ( + )14 13( – ) ( + )14 Front Pushbutton 4 Relays & Sockets 13 (–) 3PDT With Indicator (-L type) SPDT Below 100V AC/DC 3PDT 1 2 4 1 2 3 4 5 5 6 8 5 6 7 8 9 10 12 9 10 11 12 13 (–) 14 (+) 13 ( – ) ( + )14 13( – ) ( + )14 1 1 2 4 1 2 3 4 5 5 6 8 5 6 7 8 9 9 10 12 9 10 11 12 14 (+) 13( – ) ( + )14 13( – ) 1 Below 24V AC/DC 8 9 12 13( – ) 1 24V AC/DC and over ( + )14 4 5 ( + )14 4 5 8 9 12 13( – ) ( + )14 When the relay is energized, the indicator goes on. • Relay coils less than 100V DC do not contain a protection diode (except DPDT). • Relay coils below 100V use LED indicator, coils above 100V use neon lamp indicator. Timers 13 (–) DPDT 1 9 100V AC/DC and over 4PDT With Diode (-D type) 13 (–) DPDT 1 1 5 9 14 (+) 3PDT 4 1 5 8 5 9 12 9 13( – ) ( + )14 13 ( – ) 4PDT 4 1 6 8 5 6 7 8 10 12 9 10 11 12 ( + )14 13( – ) 2 2 3 4 ( + )14 Contains a diode to absorb the back emf generated when the coil is de-energized. The release time is slightly longer. Available for DC coil only. • Diode Characteristics Reverse withstand voltage: 1,000V Forward current: 1A Terminal Blocks SPDT Circuit Breakers USA: 800-262-IDEC Canada: 888-317-IDEC 731 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Relays & Sockets RH Series Display Lights Switches & Pilot Lights With Indicator LED & Diode (-LD type) SPDT 3PDT 4PDT DPDT 1 Below 100V DC 1 2 4 1 2 3 4 9 5 6 8 5 6 7 8 9 10 12 9 10 11 12 13 (–) 14 (+) 13( – ) ( + )14 13( – ) ( + )14 Below 24V AC/DC 4 5 8 9 12 ( + )14 13( – ) Contains an LED indicator and a surge absorber, and has the same height as the basic type. 1 1 2 4 1 2 3 4 1 5 5 6 8 5 6 7 8 5 8 9 10 12 9 10 11 12 9 12 9 100V DC and over 1 5 14( + ) 13 ( – ) 13( – ) ( + )14 13( – ) 24V AC/DC and over ( + )14 4 13 (–) 14 (+) Dimensions (mm) RH2B-U/RH2B-UL/RH2B-UD/RH2B-ULD Total length from panel surface including relay socket SH3B-05: 61.5 (63.5) max., SH3B-51: 39.6 (41.6) max. Dimensions in the ( ) include a hold-down spring. Dimensions in the ( ) include a hold-down spring. ø2.6 hole 4.7 4.7 Dimensions in the ( ) include a hold-down spring. ø2.6 hole 1 4 5 8 9 12 13 14 13 14 6.4 0.5 35.6 max. 6.4 21 8 10 11 14 6.4 RH1B-UT 31 RH2B-UT Dimensions in the ( ) include a hold-down spring. ø2.6 hole 4.7 ø2.6 hole 0.5 10 4.7 Total length from panel surface including relay socket SH4B-05: 61.5 (63.5) max., SH4B-51: 39.6 (41.6) max. 4.7 Timers RH4B-U/RH4B-UL/RH4B-UD/RH4B-LD 6 9 13 35.6 max. 4 5 1 1 3.5 14.5 2 3 5 6 7 8 9 10 11 12 13 2 35.6 max. 5.4 6.4 2 21.5 35.6 max. 12 13 14 6.4 14 6.4 41 RH4B-UT ø2.6 hole 4 8 10 12 14 2 3 6 7 8 9 10 11 12 31.5 732 35.6 max. 6.4 35.6 max. 6.4 7.25 2 7.25 13 21.5 42 max. 4 5 28 1 6 9 5.9 2 5 44 38 43.2 38 5.9 1 13 3.5 0.5 4.7 2 28 ø2.6 hole 0.5 4.7 3.5 4.7 10 10 4.7 10 10 10 RH3B-UT Circuit Breakers 3.5 4 8 9 27.5 0.5 1 35.6 max. 5.9 6.6 Terminal Blocks ø2.6 hole 4 5 7.25 13 14 4.7 9 43.2 38 27.5 43.2 38 5.9 5 27.5 35.6 max. 2 1 14 4.7 5.4 27.5 0.5 1 0.5 27.5 5 9 0.5 ø2.6 hole RH3B-U/RH3B-UL/RH3B-D/RH3B-LD Total length from panel surface including relay socket SH2B-05: 61.5 (63.5) max., SH2B-51: 39.6 (41.6) max. 4.7 Relays & Sockets Total length from panel surface including relay socket SH1B-05: 61.5 (63.5) max., SH1B-51: 39.6 (41.6) max. 27.5 RH1B-U/RH1B-UL/RH1B-UD/RH1B-ULD 14 28 41.5 www.idec.com Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Relays & Sockets RH Series Dimensions con’t (mm) Switches & Pilot Lights RH1V2-U/RH1V2-UD RH2V2-U/RH2V2-UL/RH2V2-UD 8-ø2.4 holes 4.7 0.5 3-ø2.4 holes 7.25 0.5 14 12 14 35.6 max. 4.4 7.8 10 RH3V2-U/RH3V2-UL/RH3V2-D 21 4.6 14.2 RH4V2-U/RH4V2-UL/RH4V2-UD 10 10 14-ø2.4 holes 2 4.7 10 13.15 4 7 8 10 11 12 14 0.5 4.6 7.8 3 6 9 13 7.25 31 2 5 7.25 14 13 27.5 1 0.5 11 27.5 8 10 7.8 4 6 9 0.5 35.6 max. 2 5 13.15 2 0.5 1 Display Lights 30 11-ø2.4 holes 4.7 4.6 8 9 2 35.6 max. 4 5 13 27.5 1 5 14 12.5 0.5 9 6.6 27.5 5 13 13.15 1 0.5 7.15 2 4.7 2 1.5 2-ø2 holes 0.5 41 35.6 max. 4.6 Relays & Sockets Standard DIN Rail Mount Sockets SH1B-05 SH2B-05 31.5 22 DIN Rail (BNDN) 18 M3.5 Terminal Screw Terminal Arrangement 2-ø4.2 Mounting Holes (or M4 Tapped Holes) 47 (Top View) ø3.2 min. ø3.6 min. 7.9 max. 5.9 max. SH3B-05 14 13 12 14.5 9 30 25 (Top View) 7.9 max. ø3.6 min. 5 4 2 1 5.5 min. 14 12 M3.5 Terminal Screw 18 Terminal Arrangement 2-ø4.2 Mounting Holes (or M4 Tapped Holes) 5.5 min. 9 46 7.9 max. 50 7 3 6 5 2 1 11 10 14 12 (Top View) ø3.6 min. 8 4 46 4.4 max. 13 10 DIN Rail (BNDN) 47 6 67 47 8 36 4.4 max. 25 8 Terminal Arrangement 2-ø4.2 Mounting Holes (or M4 Tapped Holes) 14.5 31.5 42 DIN Rail (BNDN) Terminal Blocks 67 26 4.2 18 4.2 M3.5 Terminal Screw 2.5 8 2.5 5.5 min. SH4B-05 31.5 32 40 5 1 (For terminals 13 and 14) (For terminals 1, 5, and 9) 36 8 4 26 4.4 max. 13 25 20 Terminal Arrangement 2-ø4.2 Mounting Holes (or M4 Tapped Holes) 9 4 max. 14.5 DIN Rail (BNDN) 18 Timers 2.5 67 4.4 max. 14 2.5 67 4.2 1 4.8 min. 5.5 min. 16 M3.5 Terminal Screw 5 16 M3 Terminal Screw 31.5 8 47 8 4.2 17 14.5 25 13 9 (Top View) 7.9 max. ø3.6 min. Circuit Breakers USA: 800-262-IDEC Canada: 888-317-IDEC 733 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Relays & Sockets RH Series Finger-safe DIN Rail Mount Sockets SH1B-05C SH2B-05C 36 22 17 36 M3.5 Terminal Screw 7 DIN Rail (BNDN) Terminal Arrangement ø5 1 Terminal Arrangement 2-ø4.2 Mounting Holes (or M4 Tapped Holes) 48 69 4.2 DIN Rail (BNDN) ø5 5 2-ø4.2 Mounting Holes (or M4 Tapped Holes) 25 8 5 4 1 14 13 12 9 49 25 4.2 M3.5 Terminal Screw 7 69 Switches & Pilot Lights Dimensions con’t (mm) 26 16 M3 Terminal Screw 14 13 18.7 20 (Top View) 29.5 (Top View) 29.5 SH3B-05C 7 M3.5 Terminal Screw 36 25 2-ø4.2 Mounting Holes (or M4 Tapped Holes) 6 5 4 2 1 DIN Rail (BNDN) 49 69 14 12 9 7 3 6 5 2 1 11 10 14 12 Ring terminals cannot be used. 18.7 46 1.7 29.5 40 8 4 46 13 10 (Top View) Ring terminals cannot be used. 18.7 36 Terminal Arrangement 2-ø4.2 Mounting Holes (or M4 Tapped Holes) ø5 4.2 4.2 8 25 7 Terminal Arrangement 36 1.7 36 42 DIN Rail (BNDN) 49 32 SH4B-05C ø5 13 9 (Top View) 29.5 50 Through Panel Mount Socket SH2B-51 25.6 +0.2 0 11 18.7 3 27 N: No. of sockets mounted 0.3 0.3 (Bottom View) 5.4 min.∗ Timers 3 +0.5 0 1 4 5 8 9 12 13 14 13 14 18 [27 (N–1) + 21.4] Terminal Arrangement (Bottom View) 11 18.7 5.4 min.∗ 1 5 9 25.4 31 Panel Thickness: 1 to 2 +0.2 0 [18 (N–1) + Terminal Arrangement 31 Panel Thickness: 1 to 2 12.4] +0.5 0 25.6 SH1B-51 25.4 Relays & Sockets Ring terminals cannot be used. 18.7 26 30 69 Display Lights 1.7 16 1.7 9 Ring terminals cannot be used. N: No. of sockets mounted ∗ 10.4 min. when using hold-down springs 3.5 3.5 ∗ 10.4 min. when using hold-down springs 2.4 21.2 12.2 SH4B-51 11 18.7 31 25.4 1 2 3 4 5 6 7 8 9 10 11 12 45 N: No. of sockets mounted 3 11 18.7 +0.2 0 +0.2 0 [45 (N–1) + 39.4] +0.5 0 Terminal Arrangement 13 14 (Bottom View) 0.3 0.3 3 25.6 1 2 4 5 6 8 9 10 12 13 36 Panel Thickness: 1 to 2 25.6 [36 (N–1) + Terminal Arrangement 5.4 min.∗ 25.4 31 Terminal Blocks Panel Thickness: 1 to 2 30.4] +0.5 0 14 (Bottom View) 5.4 min.∗ SH3B-51 N: No. of sockets mounted ∗ 10.4 min. when using hold-down springs 3.5 3.5 39.2 Circuit Breakers 30.2 ∗ 10.4 min. when using hold-down springs 734 www.idec.com Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Relays & Sockets RH Series Dimensions con’t (mm) Switches & Pilot Lights PCB Mount Sockets SH2B-62 15 (Bottom View) 15 (Tolerance p0.1) 5.65 10 2 8-ø2.4 holes (Tolerance ±0.1) ∗ 34 min. when using hold-down springs Display Lights 6.85 1 2 3 4 5 6 7 8 9 10 11 12 45 3 (Bottom View) 31 min.∗ 6.6 15 11-ø2.4 holes 2 (Tolerance ±0.1) ∗ 36 min. when using hold-down springs 14-ø2.4 holes (Tolerance ±0.1) Relays & Sockets ∗ 36 min. when using hold-down springs 10 10 10 14 11 39.2 45 min. 31.3 12.5 25.4 14 (Bottom View) Terminal Arrangement 13 31 min.∗ 2 31 4.7 10 10 11 15 21.3 0.3 0.3 13 3 36 7.35 12.5 6.65 25.4 31 1 2 4 5 6 8 9 10 12 4.7 6.65 SH4B-62 36 min. Terminal Arrangement 6.6 SH3B-62 30.2 25.4 2-ø2 holes 15.5 14 11 36 min. when using hold-down springs 12.2 3 21.5 min. 2.85 6.6 31 min. 2 1.5 21.2 0.3 (Bottom View) 11 1 4 5 8 9 12 13 5.95 3 Terminal Arrangement 18 min. 4.4 11.85 0.3 13 14 18 6.8 29 1 5 9 4.7 3-ø2.4 holes 4.7 6.95 31 25.4 Terminal Arrangement 29 min.∗ 12.5 SH1B-62 Timers Terminal Blocks Circuit Breakers USA: 800-262-IDEC Canada: 888-317-IDEC 735 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com