Preview only show first 10 pages with watermark. For full document please download

Release Notes Inca 7.0.0 Hotfix 25

   EMBED


Share

Transcript

Release Notes INCA V7.0.0 Hotfix 25 Copyright (c) 2014 ETAS GmbH All Rights Reserved =============================================================== Release: August 12, 2014 =============================================================== Thank you for using our products. This file contains important information. We strongly recommend that you read the entire document. For additional important information read the corresponding readme documents and INCA documentation. We welcome your comments and suggestions. _______________________________________________________________ Important Information This hotfix supports the efficient usage of INCA. It contains the most current bug fixes for INCA. The functionality of the bug fixes has been thoroughly tested. However, this hotfix has not been subject to the complete release tests of INCA. Therefore, it is not possible to guarantee the usual high quality standards for this hotfix. ETAS GmbH accepts no further obligation in relation to this hotfix. _______________________________________________________________ Installation - Minimum requirement: INCA V7.0.0 installed - Shutdown all running applications (especially all ETAS applications have to be closed) - Start the hotfix installation - After the installation a reboot is required. _______________________________________________________________ Update to the “System Requirements” with INCA V7.0.0HF1 Windows 7 SP1 is supported and recommended. Release Notes INCA V700 HF25.docx Seite 1 von 55 ____________________________________________________________________________ Bug fixes The following issues have been fixed in hotfixes as listed below. All hotfix software updates are cumulative. The most recent hotfix incorporates any changes introduced by previous hotfixes. Often used abbreviations within EHI calls KIR: Known Issue Report: For severe Problem Reports which occur after a release, ETAS has introduced the Known Issue Report to inform affected customer immediately. The current Known Issues of former versions can be found on the ETAS website: http://www.etas.com/kir CDM: Calibration Data Manager EE: INCA Experimental Environment EHI: ETAS Helpdesk International LiMa:ETAS License Manager HF: Hotfix MDA: INCA Measure and Data Analysis MIP: Matlab Integration Package MR: Multi-Recorders OS: Operating System OHI: Open Hardware Integration VSD: Variable Selection Dialog WB: Walkback, Inca system error ___________________________________________________________________ INCA V7.0.0 HF25 New features and improvements ===================================== - Support of ES581.4 - New ETAS ETK Tools package ETK Drivers & Tools V3.12.0 was replaced by ETK Tools V4.0 * The Tools part it now shipped with ETK Tools. * The ETK drivers of V3.12.0 are now part of INCA 7.0.0HF25 and will be updated/installed automatically. * For the first time the ETK Tools V4.0.0 can be installed with help of the INCA V7.0 Sevice Pack installer (new function, select check box for installation): Select ETK Tools and Install (see also ETK_Tools_V4.0.0 -Whats-new.pdf). Known issues and important hints ===================================== - see HF24 (and HF23) Release Notes INCA V700 HF25.docx Seite 2 von 55 ___________________________________________________________________ INCA V7.0.0 HF24 Known issues and important hints ===================================== - see HF23 EHI #380601 Connection of ASAP3 to INCA from within the Experiment does not work if .NET V4.5.0 is installed (no issue with .NET V4.5.1) Note: Workaround implemented with INCA V7.0.0 HF24 and INCA V7.1.3 Bug fixes and improvements ============================ EHI #367304 Communication error (CCP) during automated write/read test with powerfail (successor of #361536) EHI #368659 EE: The error message "Not Enough Memory" is thrown when opening EE for the second time EHI #368676 EE Performance: Time required to open EE got slower with INCA 7.0.0 HF22 with a specific workspace EHI #368979 CAN UDS: Freerunningmode Switch off/on during measurment leads to a stall of target server EHI #372722 Performance improvement for customer specific RAMScope: Performance during creation of generic measure device in case of more than 100 measurements EHI #375601 [WBID625331335] Flashing is not possible EHI #376561 Start INCA V7.0 after operation of INCA 7.1 without admin rights (side by side usage) Note: INCA V7.1 has to be installed EHI #376665 [WBID4188039756] Experiment could not be opened with HF23 EHI #376672 WBID668182908 system error on attempt to open EE EHI #376847 [WBID1123985822] when select ES610 in Hardware Configuration EHI #377572 Kvaser devices has no support for ES720 EHI #378046 [WBID4188039756] when open experiment that contains a VUI EHI #378054 ES610 measurement values are wrong when the workspace contains a ES595 with FlexRay Monitoring EHI #378338 INCA sends Tester Present while another service is pending EHI #380601 Connection of ASAP3 to INCA from within the Experiment does not work if .NET V4.5.0 is installed (no issue with .NET V4.5.1) EHI #382876 Pre-trigger-time cannot be saved in the measure file with XCPonEthernet EHI #2013401603 UDS flashing is not possible with ECU Release Notes INCA V700 HF25.docx Seite 3 von 55 ___________________________________________________________________ INCA V7.0.0 HF23 Known issues and important hints ===================================== Important hints for operation with ES581.3: To support multiple clients with ES581.3 a major/structural change of INCA, driver and firmware was required. - When upgrading any of the INCA Versions V7.0 or V7.1 with INCA V7.0 SP15 or V7.1 SP2 also the corresponding other version needs to be upgraded to the new version. - If J2534 is used (e.g. for 3rd party access on ES581.3), an update of the ES581-J2534 driver to V2.0.7 or higher (part of HSP V10.2.0) is required. - Ensure the USB driver is updated to the latest version (part of HSP V10.2.0) Note: The ES581.3 firmware is automatically updated from the driver (if required). Known issues with INCA 7.1HF23 and former hotfixes: - EHI #349083 Flashing with ES581.3 (and 3rd Party HW) fails - ST_MIN not respected Flashing via UDS/KWP with ES581.3 HW might fail, if a CAN frame separation time (STmin) > 0ms is used. In this case it might happen that the used separation time is sporadically lower than STmin. This is an issue with every 3rd Party HW (Vector, Kvasar, ES520). It is not issue with ES59x, ES910, ES511. - EHI #357577 ES581.3: UDS Flashing with ES581 fails Flashing with ES581.3 HW might fail, if the CAN bus load is high before flashing is started and the time from last HW initialization of ES581.3 till start of the flashing is too long. To avoid the failure, start flashing immediately. New feature - major bug fix ===================================== - Multiple client support of ES581.3. - Related ES581.3 calls solved - Known issue with ES581.3 solved: > EHI #347726 ES581.3: No measurement via IPETRONIK or CSM possible if both ES581.3 CAN ports are used. Bug fixes and improvements ============================ EHI #336147 ES581.3: USBLatency setting slow down flash performance EHI #344994 ES581.3: CCP Monitoring buffer oveflow at high busload EHI #347726 ES581.3: No measurement via IPETRONIK or CDM possible if both Release Notes INCA V700 HF25.docx Seite 4 von 55 ES581.3 CAN ports are used. Known issue with ES581.3 solved. EHI #349047 ES581.3: If 2 devices (CCP/Ipetronik) are used and Ipetronik is initialised as the second device then initialisation fails EHI #349384 ES581.3: No function of the CSM modules with the ES581.3 EHI #365841 ES581.3: Target Server crashes while measuring with ES581 over UDS EHI #368813 ES581.3: Gap in Timestamp after 5000 Sec. EHI #370391 ES581.3: Deterioration of CCP Flashing performance compared to INCA V700 HF8 EHI #372012 ES581.3: After Flashing of the ECU, the HW initializing do not respond if the CAN 2 is initialized EHI #351590 Raster information is not shown in INCA with connected Hardware Note: Solved with ETK D&T V3.11.0 (part of the SP) EHI #364983 Targetserver crash during flashing EHI #365264 Doubled display of ES921-device and not present ES920 in HWC-search if CSM AddOn installed EHI #365839 Error indication on ES1000 after installation Partner_addOn products EHI #367438 and #367690 EE: Measurement with abs(x) not updated in widgets EHI #367801 CSM Addon did not run properly with used INCA command updateFromSearchResultUseCase- Msg: Invalid use case EHI #368296 Difference in CDM compare is not detected EHI #371147 MPM actions for ETK S6.0 seem to do incorrect copy actions Note: Solved with ETK D&T V3.11.0 (part of the INCA SP) ___________________________________________________________________ INCA V7.0.0 HF22 Known issues and important hints ===================================== ES581.3: See HF19. Bug fixes and improvements ============================ EHI #97911 CSE: Wrong state in VSD after adding label with same name from different device to CSE EHI #323817 Hotline Contact Information outdated EHI #326587 ES690 - HW init issue with CANMon and CCP at one CAN bus if not ES690 default baud rate (500kBaud) is used EHI #347079 CAN-Monitoring does not change initial baud rate setting EHI #347178 Faulty slew icon displayed on the dataset after reading the Release Notes INCA V700 HF25.docx Seite 5 von 55 hex file. Note: Already solved with INCA V7.0.0HF21. EHI #347835 ES593: After disconnect and reconnect Ethernet, the CAN Monitoring on CAN1 is no longer possible EHI #348732 CDM: Dependent labels are unexpected computed when using A2L and Data Transfer File EHI #349096 [WBID1309351448] System error during MCE label configuration Note: Requires INCA AddOn MCE V1.1.3 (part of INCA 7.0.0SP14) EHI #350243 INCA memory increases as run MCD3 tests causing PC to freeze and INCA to crash EHI #350908 Set the same serial number for two different ES581.3 devices EHI #351870 [WBID1811049737] System error during INCA session EHI #352649 CAN Monitoring data timestamp jumps during recording EHI #352708 [WBID3185843499] at opening experiment or when starting HWC dialog EHI #353955 [WBID4070127963] Walkback when open experiment EHI #354194 LCA: Cannot write StringArrayParamVar EHI #355040 If SEED_AND_KEY() was called twice, the second call always returns "0"(error). EHI #355604 After saving an experiment the modified values are getting lost EHI #356804 Data samples missing from ECU with XCPonCAN measurement in the mdf-file EHI #356922 [WBID2799303568] when search for HW in HW editor EHI #357188 IPM Server configures ETAS network in the last known CN subnet address range EHI #357387 [WBID669325502] System error during INCA session EHI #358113 Recorder file is not saved using ASAP3 EHI #359314 [WBID3087534066] Sporadic WB during INCA session EHI #359583 ErrorCode 517 when save database with INCA 7 type EHI #360410 [WBID3489611665] System Error during INCA session EHI #361536 [WBID3417850026] with SW bundle 24 during EEPROM writ e/read test with power fail EHI #362104 IPE Devices would not recognized due start the EE EHI #362942 INCA lock up when perform checksum routine after flash on Win 7 PC. EHI #363548 After an error in RCI2 interface, IncaGetLastError returns "No Error found", which is wrong Release Notes INCA V700 HF25.docx Seite 6 von 55 EHI #364161 Connection to ECU broken after automatic firmware check EHI #364177 Icon of OnlineFirmwareCheck incorrect in HWC for ES592/ES593/ES595/ES581 EHI #364514 [WBID59071569] while opening INCA Experiment via EE EHI #366195 INCA 7.0 HF20/21 VCRedist 2010++ 32bit needed Note: Solved with ETK D&T 3.9 and subsequent (part of SP14) EHI #366304 Opening HWC of a LIN device without an assigned project causes an OHI Error Message Note: Solved with INCA AddOn LIN V7.0.3(part of SP14) EHI #366579 Optional COM API Logging with time stamps - backport INCA V7.1 EHI #368402 Installation: If the "Tools" from ETK Drivers & Tools are installed and the .NET V4 package is missing, then the installation is no finished correctly EHI #368437 [WBID2799303568] when search for HW in HW editor EHI #368460 Redo does not work for Scalar Table Editor EHI #368561 ETK_D&T 3.10.0 Distab 17 wrongly configured in case of doubled addresses - KIR issue solved. Note: Requires INCA-AddOn ETK D&T V3.10.1 (Part of INCA 7.0 SP14) EHI #2012406038 [WBID3218871388] solved - backport from INCA V7.1.1 EHI #2013401387 INCA freezes after UDS flashing with ES581.3 ___________________________________________________________________ INCA V7.0.0 HF21 Known issues and important hints ===================================== ES581.3: See HF19. Bug fixes and improvements ============================ EHI #350411 ToolAPI issue: it is not possible to add ES581 device via GetDeviceDescription method Script adapted. No product change. EHI #350733 CDM comparison in Inca 7 with few labels is very slow EHI #352933 [WBID1068249489] Exit due to error: 60 - Exit due to walkback when a certain experiment is being selected in the database tree EHI #353786 MeasureCal shows wrong value if calibration was changed by EE instrument EHI #354101 Slews: Slew behavior changed and icon is not being displayed on the proper data set Release Notes INCA V700 HF25.docx Seite 7 von 55 EHI #354189 Additional CAN Transmit device is added when perform replace EHI #354344 INCA V7.0.0 [WBID2252893887] INCA V7.1.0 [WBID3914582808] when opening experiment Solved for both INCA versions. EHI #354573 Not possible to display the process point EHI #355071 When selecting BOA hardware in BUSMASTER, the HW is not found EHI #355263 MCD 3 MC V2.2 : Internal Error at IMCCollectors.Add EHI #355641 Wrong direction of changing phys value EHI #356052 Unexpected Monitor-log entry after using Convert Experiment --> Write Template EHI #356055 Conversion file uses wrong ASAP2_VERSION EHI #356199 Server Busy message and Walkback encountered when using UFE "Force Running Reset" EHI #357131 CDM WBs ([WBID2415885070], [WBID4035783185]) after API-Access EHI #358148 WBID3642544362 System Error reading from file in CDM EHI #358310 [WBID3269616446] Memory optimization message and walkback when open and close experiment multiple times EHI #358625 [WBID177740905] when opening experiment EHI #359167 [WBID23588784] INCA V7.0.0: System error opening Experiment EHI #359761 Undo from Calibration Actions in the Scalar Table Editor does not work for Grouped Devices EHI #362219 OHI Error Message when open EE with Lin Device Note: Requires INCA Add-On LIN V7.0.2 (part of INCA V7.0.0SP13) EHI #362574 FlexRay EE is not usable because no label is available Note: Requires INCA Add-On FlexRay V7.0.7 (part of INCA V7.0.0SP13) EHI #363688 In Asap3 every measurement loop creates old + new file (partly solved) EHI #87145 Performance improvement: INCA consumes too much RAM using MCD3 EHI #92245 System Error at copy and paste of folders EHI #2012405737 The name of raster is not displayed completely EHI #2012405982 [WBID585474223] System error when add Daisy chain device Already solved with INCA V7.0.0SP12.1 (together with the updated DaisyChain AddOn V1.3.4) ___________________________________________________________________ INCA V7.0.0 HF20 Release Notes INCA V700 HF25.docx Seite 8 von 55 Known issues and important hints ===================================== see INCA V7.0.0 HF19 Bug fixes and improvements ============================ EHI #356818 XCP-Download to working page (WP) is not possible ___________________________________________________________________ INCA V7.0.0 HF19 Note on May 06, 2013 - INCA V7.0.0HF19 was not released on the ETAS download page due to issue EHI #356818 XCP-Download to working page (WP) is not possible with INCA V7.0.0 HF19. This is solved with INCA V7.0.0 HF20. Known issues and important hints ===================================== - ES581.3: > EHI #347726 ES581.3: No measurement via IPETRONIK or CSM possible if both ES581.3 CAN ports are used. Multiple clients are not supported. Only one SW application can set the CAN configuration, e.g. baudrate, for the ES581.3. The application that accesses the ES581.3 first is able to configure each CAN channel independently. The application accessing the ES581.3 second, e.g. a third party SW or an INCA AddOn, can only reuse the settings made by the first application. If the HW module that the second application accesses needs a configuration that differs from the configuration already set, the use of that module will fail. Known issue solved ============================ EHI #351788 Time leap using ES580 During a measurement of long duration, a time stamp jump in the recorded measure file(s) may occur. The issue depends on the duration the HW is plugged into computer (and timer increasing). Affected HW: All supported Vector modules (e.g. ES580, VN7600, CANCase XL, CANCard XLe, CANLink, CANCard X, CANCard XL) Bug fixes and improvements ============================ EHI# 98564 It is not possible to initialize ES595 if only Ipetronik is configured EHI# 2010403395 Focus after deleting DB items missing, add elements icons active Already solved with INCA V7.0.0HF18 Release Notes INCA V700 HF25.docx Seite 9 von 55 EHI# 2011403903 A2L with more than 26 "RESERVED_DISTAB_MEMORY" entries cannot be assigned to ETK device EHI# 2012404400 Vertical scroll bars in EE are inactive EHI# 2012404872 Limited ERAM: If "output" component of a MAP is write protected, it is not possible to calibrate axises from the combined editor. EHI# 2012404949 [WBID906108180] when opening experiment Already solved with INCA V7.0.0HF18 EHI# 2012405549 [WBID1080142799] during INCA session EHI# 2012405759 Dependent parameter get not calculated correctly after copy action in CDM Already solved and shipped with INCA V7.1.0HF17 EHI# 2012405799 MCE-Error 0x80001003 when configuring the variables for EtherCAT communication. Message on the testbed side is "Unable to Toggle to SAFE-OP State on FULI Device" Same issue as in Call #348908. Solved with INCA-MCE V1.1.2 (required, part of SP12). EHI# 2012405806 Focus to select variables is lost when working with ALT -TAB EHI# 2012406004 Re-Init with CAN-Monitoring doesn't work EHI# 2012406315 [WBID4070127963] while open experiment Already solved with INCA V7.0.0HF18 EHI# 346634 No measure data displayed in INCA on a XCP on Flexray ECU Incorrect response to error assigning DAQ list slots EHI# 347695 INCA hangs during XCP init EHI# 347835 ES593: After disconnect and reconnect Ethernet, the CAN Monitoring on CAN1 is no longer possible EHI# 348002 Not possible to read a given Fibex file into INCA database INCA FlexRay AddOn V7.0.6 required. EHI# 348111 [WBID2758593614] during INCA session with given project EHI# 349123 FlexRay Monitoring loses PDUs Note: Solved with FlexRay AddOn 7.0.6 (required) EHI# 349506 [WBID4070127963] when opening the experiment EHI# 349616 CDM freezes or creates fatal error Solved with #350757 EHI# 349662 GPS data recorded by INCA V7.0.0 and ES720 (V7.0.0) respectively are incorrectly displayed in MDA EHI# 349770 [WBID977812319] if an output signal is assigned to the ES930 in the EE Already solved with INCA V7.0.0HF18 Release Notes INCA V700 HF25.docx Seite 10 von 55 EHI# 350230 If last used database is on a network share an error occurs on opening Inca EHI# 350406 INCA V7.0.0 HF18 beta 6 does not start EHI# 350503 IPETRONIK modules loses connection to INCA when ECU goes into power off EHI# 350757 Memory management - support of huge project improved EHI# 350950 INCA feature 'ETK Reset Security' does not work anymore for generic ETK EHI# 351063 [WBID2428229303] STRG+U RBDataVector does not understand axis Already solved with INCA V7.0.0HF18 EHI# 351310 CDM can not read DCM Lists Already solved with INCA V7.0.0HF18 EHI# 351582 [WBID2428229303] occurs when returning to reference values via "ctrl+u" shortcut Already solved with INCA V7.0.0HF18 EHI# 351624 [WBID518082257] when perform "Write Template" operation EHI# 351629 [WBID2428229303] error message when changing the calibration value via "ctrl+u" Already solved with INCA V7.0.0HF18 EHI# 351788 Time leap using ES580 "Known issue solved Details see "known issue solved" above. EHI# 351821 ES910: Non UTF-8 characters (Unicode) in configuration XML not supported by ES910 API Solved with INCA Add-On MCE V1.1.2 (required) EHI# 353161 Error "It is not allowed to wire values from FULI-LUNs into a recorder [60835]" ... in ASAP3 when adding values to INCA Recorder (not to FULI LUN) EHI# 353252 [WBID448902737] CDM: The setting ASAM2MC of the compare mode leads to WB during listing of different items EHI# 353255 Impossible to start INCA after installing SP10 or SP11 EHI# 353283 No Ethernet connection to HW possible, if the search for HW or init is started, during the windows 7 network identification task is active EHI# 353499 IPM: DHCP-Check when the DHCP Server provides IP addresses in the APIPA range reserved by Microsoft The check is switched off (like INCA V7.0.0HF14 and former versions). The pre-condition is, that the NIC used for IPM Server has the IP address in APIPA range (169.254.0.1 - 169.254.255.254). ___________________________________________________________________ INCA V7.0.0 HF18 Known issues and important hints Release Notes INCA V700 HF25.docx Seite 11 von 55 ===================================== New known issues: - ES581.3: > EHI #347726 ES581.3: No measurement via IPETRONIK or CSM possible if both ES581.3 CAN ports are used. - No measurement if 2 CANs are used, one for INCA (e.g. CCP), another for a CSM or IPETRONIC module. - Another issue if baud rate of two CAN channels is different. Currently only one baud rate supported. If a second CAN is initialized with a second baud rate, the baud rate of the first CAN might be overwritten. - Recommendation: Use only one CAN-channel - New ES581.3 devices with new Serial Numbers (S/N) and update of all ES581.3 devices - see important hints of INCA V7.0.0 HF17 (Note: update could be done with HSP V9.9.2 as well) EHI #347824 Adobe Reader V11.0.1 block the command ''Variable Documentation'' This is due to a missing/wrong registry setting with Acrobat 11. Workaround: Change corresponding Acrobat registry setting until the issue is solved by an Acrobat update. E.g. add the following to an acrobat11.reg file and execute it (double click) to change registry-setting or change it completely manually: Windows Registry Editor Version 5.00 [HKEY_CLASSES_ROOT\acrobat\shell\open\ddeexec\application] @=""AcroViewR11"" Known issue solved ============================ EHI #2012403746 [WBID2233574518] during CCP over ES910 measurement Known issues reported with INCA V7.0.0 SP7(HF13) and HSP V9.7.0 On high performance PCs (normally running Win 7 64Bit) some technical limitations could occur using ES910 and CCP concurrently on several CAN channels with high bus load. In case of ES910 and several CCP-ECUs it is still recommended to use INCA V7.0.0 SP6/HF12 together with HSP V9.6.1 It is planned to solve the issue with the next version. Bug fixes and improvements ============================ EHI #2011402629 Column width changes Already shipped with another solution with INCA V7.1.0 HF6 Release Notes INCA V700 HF25.docx Seite 12 von 55 EHI #2011404715 CDM Compare of data sets takes 15 minutes EHI #2011408826 WB [1330975451] while opening experiment from older INCA version V5.4.1 EHI #2012403455 Errors during import of a CDF file as a dataset EHI #2012403746 [WBID2233574518] during CCP over ES910 measurement Known issue reported with INCA V7.0.0 SP7(HF13) and HSP V9.7.0 solved. EHI #2012404097 Default recorder does not start after removing variables in the experiment Already solved with INCA V7.0.0 HF16. EHI #2012404162 [WBID1523572377] INCA stops completely during sending the stop during an automated sequence EHI #2012405160 Segment wise page switch leads to inconsistent data in ECU EHI #2012405281 Measurement values are irregularly updated in the EE during visualization and recording Already shipped with INCA V7.0.0 HF17. EHI #2012405301 Calculated Signals get not loaded in the yT oscilloscope EHI #2012405399 Invalid analog signal over ES595 EHI #2012405502 CDM: Copy of array shows no error even if hard bounds exceeded If a cell of an array exceeds the hard bounds, no error or warning is shown and the cell value is clipped to the hard bounds. EHI #2012405547 Wrong value is displayed in experiment EHI #2012405678 Experiments hangs during measurement EHI #2012405708 [WBID1789765672] During windows configuration in the experiment, moving a window with the courser EHI #2012405843 [WBID1931694180] when opening the EE EHI #2012405893 [WBID2637493711] while reading HEX file. EHI #2012405918 It is not possible to import Exp-file with dataset (created via ToolAPI) to the existing data base EHI #2012406003 Display of variables in GUI stops after some time when using "Timestamp_supported" in A2L file. EHI #2012406039 XPonEnt communication is not possible after switching between ECU-project - it is not possible to use WP and RP EHI #2012406095 [WBID3727437600] accessing or using the keyboard shortcut CTRL + T for changing view of a map editor EHI #2012406102 Measuring buffer overflow when using a special experiment on a laptop with XP SP3 EHI #2012406136 [WBID475944959] during a INCA session Release Notes INCA V700 HF25.docx Seite 13 von 55 EHI #2012406421 CSM module ADMM incorrectly represented in the hardware config editor with 8 channels instead of 4 channels EHI #2013400197 [WBID3920615049] walkback occurs while converting a dat file to an ASCII file Workaround: MDA can be used for convert to ASCII. EHI #279278 It is not possible to initialize ES595 if only Ipetronik is configured Note: Improved to the same behavior like with INCA V6.2.1HF21 and subsequent. But System-Mapping-Dialog still not provided automatically with ES690/ES910/ES5xx and Ipetronik-AddOn. Workaround: Execute SFH (search for hardware) manually. EHI #309455 Using a FORMULA CompuMethod leads to error on measurement start with MCE EHI #311239 A2L Parsing Error when using the expression "/include file.aml" EHI #323450 [WBID1845261986] OrderedCollection does not understand getDefaultPhysValueFor:formula EHI #326545 [WBID152773687] EtasEnhancedDatabaseDialog does not understand writeUserOptionsToIniFile EHI #330008 Variable find feature does not highlight the expected variable EHI #333431 Reading of A2l File with XCPplus(AML V2.0) definition not possible EHI #335928 ASAP2 LAYOUT ROW_DIR not supported Support of the ASAP2 keyword LAYOUT (for AUTOSAR project using Measure Arrays) EHI #337731 CDM copy reports no errors but variable is not copie d EHI #338471 ES581.3 Flash performance: Duration of the flashing action lies between 60 seconds and 480 seconds EHI #339019 [WBID2647750935] when open special workspace EHI #340883 [WBID1168902146] after changing "Overlay Properties" EHI #342186 ASAMMCD3MCV22: WriteReadRecoder.deactivated doesn't stop the running Recording. -> Error eRT_NOT_ALLOWED_IN_THIS_OBJECT_STATE at oLogicalLink.DisconnectFromModule() Solution was already shipped with former INCA V7.0.0 HF15/16 EHI #343832 [WBID3701453531] when open a special workspace EHI #344193 CAN Monitoring J2534 ES581 Timestamp not correct after about 4000 sec Requires also driver update for J2534 and ES581 with HSP V9.9.1 EHI #344560 [WBID3276210548] when clicking on special ECU EHI #345030 [WBID419512931] when open special EE EHI #345457 [WBID3169589889] when setting alias name via menu in HWC Release Notes INCA V700 HF25.docx Seite 14 von 55 EHI #345586 It is not possible to read a2l file with Unicode(UTF8) with BOM due to error EHI #346112 Cannot open database from "not connected" network share EHI #346266 COM API - CDM runs out of memory when compare is started via COM API EHI #346661 A2L file cannot read in with an additionally AML notation in the MEMORY_SEGMENT section. EHI #346758 Win7 (x64) 512 Data file loop detected INCA DB crashed EHI #347236 [WBID3335207883] when using CSE EHI #347321 Adaptive maps of given project not updated with SP V9.1 EHI #347388 ASAP3-crash using "GET USER DEFINED VALUE LIST" EHI #347399 [WBID2200047011] when open special EE with ASAP2 EHI #347411 VIRTUAL_MEASUREMENT - Back port of the support of IF_DATA CANAPE_EXT to INCA 7.0 EHI #347455 [WBID579070364] While open a HTML File in CDM a system error occurred EHI #347456 Crash solved: New method to display icons in case of corrupt a2l-file EHI #347458 The output configuration of FLOAT32 does not save phys bottom/top values - enhancement of #338687 EHI #347587 CDM shows always an message in the monitor-window if a filter is in use EHI #347973 [WBID579070364] EHI #348008 [WBID2601018573] while open a HTML file in CDM + [WBID2637493711] during loading of experiment EHI #348009 [WBID2637493711] while loading an ECU-Project(A2L+Hex) EHI #348378 [WBID1434558840] and [WBID272884890] when navigation in ECU EHI #348732 CDM: Dependent labels and Data Transfer File are unexpected computed when using A2L EHI #349123 FlexRay Monitoring looses PDUs Note: Solved with FlexRay AddOn 7.0.6 (required; will be released soon) EHI #349251 Change markers missing for shared axis in "Combined Editor", if data is read in by calibration file EHI #349402 [WBID821851098] when double click on ECU of a INCA V7.1.0 project imported in INCA V7.0.0 EHI #349510 .Net crash of VSD if change variable to inactive EHI #349704 [WBID1200184091] Daimler Extensions: Moving Ctrl -F dialog in project causes WB Release Notes INCA V700 HF25.docx Seite 15 von 55 EHI #349839 After starting visualization, size of "Measure Table" i s changed and values are not visible EHI #349841 Long Name is not any longer copied when copy Measure Labels in ASAP2 Editor ___________________________________________________________________ INCA V7.0.0 HF17 Known issues and important hints ===================================== - New ES581.3 Devices with new Serial Numbers (S/N) and update of all ES581.3 devices Newly shipped ETAS ES581.3 devices (S/N >40000) have an extended range for the serial numbers. INCA V6.2.1 HF33 and INCA 7.0HF 13 and subsequent releases support these new devices (see EHI #332119 Serial number range for ES581.3 for recognition as ETAS device extended) !!! Important !!! There is an update with HSP 9.9.1 or higher required to support ES581.3 devices (new and old versions) and take advantage of the fixes shipped with this HF (INCA V7.0.0HF17) Please install the ES581 USB Drivers and J2534 Drivers shipped with HSP V9.9.1 Note: - New devices (S/N >40000) cannot be downgraded to a firmware version lower than HSPV9.6.1 - If the updated ES581 - drivers are not installed, INCA might not find or operate the new devices with extended serial numbers (all new shipped devices affected). - The devices might not operate correctly with INCA V7.0.0HF17 or higher, if the J2534 driver is not updated with HSP V9.9.1 or higher. Bug fixes and improvements ============================ EHI #2011404662 INCA generates inconsistent message counter on CCP communication EHI #2012402317 ECU connection breaks during Flash EHI #2012402379 Calibration of Mappings with several cells using ES581.3 leads to communication loss to ECU EHI #2012403687 INCA hangs when working with a huge datasets in CDM Partial solution shipped with INCA V7.0.0 HF15. Now further improved for Win XP and Win Win7. EHI #2012404058 LCO V5.1.2 / EE3.3.1/1: Crash - Index was out of range EHI #2012404162 [WBID1523572377] INCA stops completely during sending the stop during an automated seqence. Release Notes INCA V700 HF25.docx Seite 16 von 55 EHI #2012404266 [WBID4157865031] Opening EE EHI #2012404303 ProF compressed flashing via UDS not possible. To flash compressed data via UDS it is necessary to set the end address to 0. In this case Prof returned an error: Memory area 2 not defined in CNF file." EHI #2012404317 ES_I710.65: Replace System with ES520 by ES581.3 not possible EHI #2012404399 [WBID667152105] Inca crash on reimport saved csv Excel file with map EHI #2012404414 Flashing is not possible with ES581.3 EHI #2012404474 Flashing using ES581.3 failed EHI #2012404704 CCP inconsistency during CCP download EHI #2012405081 "Exception occurred" error after WriteReadRecorder. Deactivate() when the WriteReadCollector was activated only (start-stop commands were not used) EHI #2012405102 [WBID2986428855] INCA crashes on Win 7 PC when one tries to select the network drive via its letter (Registry Entry "EnableLinkedConnections=dword:00000000") EHI #2012405115 The output configuration of FLOAT32 does not save phys bottom/top values EHI #2012405273 [WBID1793154450] System error when loading CDFX file in CDM as source EHI #2012405341 ES580: INCA frozen for 2-3 sec. if switched between layers and notebook in use EHI #2012405372 No Flexray value shown in INCA EHI #2012405437 CCP inconsistency with ES581 device EHI #2012405471 Registration problem of INCA components if installation path includes spaces - No proper operation possible EHI #2012405552 PaCo files written with false SW-CS-ENTRY attribute The time attribute is written with "t" instead of "T". EHI #2012405608 [WBID3313097948] System error while variable selection EHI #2012405612 INCA does not start at all due to issue with Standard Dialogs used by ASCET and INCA on the same computer Same like #341837 " EHI #2012405683 [WBID1474063629] System error during INCA session EHI #2012405739 [WBID238867121] Opening the VSD EHI #2012405759 Dependent parameter get not calculated correctly after copy action in CDM EHI #2012405769 INCA crash at PARAMETER FOR VALUE ACQUISITION command of Release Notes INCA V700 HF25.docx Seite 17 von 55 ASAP3 session with the large experiment EHI #2012405778 [WBID3313097948] While variable selection EHI #2012405848 "Complexity validation" error on ES720 EHI #2012405860 XCPonEth + CCP+CAN-Mon: Time offset in the measure file EHI #2012405896 Time delay in Can-monitoring and XCP measurement via ES581.3 EHI #2012405945 ES720 - Stop-Trigger doesn't work . Blocking for ES720-UseCase EHI #2012405993 VUI: Order of variables when reading the file *,names is not be considered EHI #2012406026 [WBWBID3109871623] WB during start of EE EHI #2012406078 CDM shows "R" names but a user option = ""D" only" CDM - function view: If a user option "shows D variables only" is active and the function view is active and the function with "R" and "D" variables is selected INCA should display the "D" variables only but the axis ( --> "R" variable) is visible " EHI #2012406195 [WBID3754308073] CDM: WB after select all diff. signals EHI #329770 Already selected filter in VSD of Trigger Editor does not display signals in experiment EHI #335370 [WBID906108180] Walkback when auto remap rasters in experiment EHI #338050 ES581.3: Error Message: Queue event - the receive queue has overflown if you calibrate a big number of calibration values EHI #338884 .NET Framework error when change record state and sort in Variable Configuration dialog EHI #339723 ES720: CCP connection not being restored every time after ECU power cycle EHI #339793 ES591/ETK D&T V3.6.0: No measurement possible unsing all rasters Solved with INCA V7.0.0HF17 EHI #340377 CAN, CCP: No automatic reinit after multiple off on ECU KL15 EHI #340723 [WBID3269616446] CDM: WB when performing copying with large datasets and multiple destinations EHI #340827 ES6xx data drop outs after about 40 minutes of recording EHI #341031 When using "Display Mode" it is possible that after clicking into graphical area not the expected area is shown EHI #341050 ES590; COM: HWInit & Start Recording fails EHI #341177 Not possible to assign project to XCP device if a2l was read using Shift_JIS encoding EHI #341186 Unexpected behavior when using "Multi Selection" in the graphical area Release Notes INCA V700 HF25.docx Seite 18 von 55 EHI #341309 Performance: INCA VRAM consumption increased EHI #341784 ES415 Online Help: Extend map file for context sensitive mapping EHI #341792 [WBID823754594] when saving experiment after setting some variables in VUI->Osci inactive EHI #341797 When using a XCP ECU with a HWC with a Ipetronic device, the XCP data has time-jumps of about -2 seconds EHI #341837 Installation : INCA doesn't start Same like #341107 EHI #343673 Targetserver crash in a1b_CCPCan.dll EHI #343884 The Windows Timer may have a too low resolution for the targetserver Within the targetserver it is ensured that the time resolution used for the 'Sleep()' functionality is at least 2 ms. EHI #344285 ASAP3: PARAMETER FOR VALUE ACQUISITION returns with error "Unable to obtain a raster for the following variables (check your ASAP2 file): [60828]" by calculated Signals EHI #344355 [WBID626530968] after try to save EE (inactive) EHI #344939 Sub VUIs are not any longer used Side effect of INCA V7.0.0HF15 solved. ___________________________________________________________________ INCA V7.0.0 HF16 Note: INCA V7.0.0HF15 was not released at the ETAS Download Page due to found side effect EHI #2012405779. Known issues ===================================== See INCA V7.0.0 HF15, please. Bug fixes and improvements ============================ EHI #2012405882 EE form 100Mbit_ETK_AML cannot be used with XETK_AML -project The DAMC4 - compatibility-checks (8Mbit vs 100Mbit) in loading or saving the EE were removed. EHI #2012405779 Flash process fails after erasing the flash. Side effect introduced with INCA V7.0.0 HF15 solved. ___________________________________________________________________ INCA V7.0.0 HF15 Note: INCA V7.0.0HF15 was not released at the ETAS Download Page Release Notes INCA V700 HF25.docx Seite 19 von 55 due to found side effect EHI #2012405779. Known issue ============================ - KIR PR 2012404415 (also published on the ETAS Download Center) is solved with INCA V7.0.0 HF15 - see also known issues of the SP9 release notes - New ES581.3 Devices with new Serial Numbers Newly shipped ETAS ES581.3 devices (S/N >40000) have an extended range for the serial numbers. INCA V6.2.1 HF33 and INCA 7.0HF13 and subsequent releases support these new devices (see EHI #332119 Serial number range for ES581.3 for recognition as ETAS device extended) !!! Important !!! There is also an firmware-update with HSP 9.7.0 or higher required to support new ES581.3 devices. Please install the ES581 USB Drivers (V2.4.16) and J2534 Drivers (V2.0.1) or higher versions. New devices (S/N >40000) cannot be downgraded to a former firmware version with HSPV9.6.1 Note: If the updated ES581 - drivers are not installed, INCA will not find or operate the new devices with extended serial numbers (all new shipped devices affected). Bug fixes and improvements ============================ ____________________________ KIR Issue solved: - EHI #2012404415 Calibration outside from hard bounds possible if the defined range includes a singularity KIR PR 2012404415 (published on the ETAS Download-center) If within the A2L a COMPU_METHOD with a (possible) singularity (1) is defined (e.g. f(x)=1/x) AND this COMPU_METHOD is used to calculate the hex value out of phy values of a parameter AND the defined range (including boundaries) wrongly includes the singularity of this COMPU_METHOD (here x=0; e.g. a range [0, 2000]) AND the value (hex or phys) of the parameter is changed outside the defined boundaries within the experimental environment of INCA (here: e.g. x= -20) THEN INCA does not detect, that the value of the parameter is outside the boundaries and the value is wrongly transmitted to the ECU. Note: (1)Singularity respectively pole of the function is a point at which a given mathematical object (function) is not defined [e.g. division by zero]; infinity; f(x)=1/x at x=0) Release Notes INCA V700 HF25.docx Seite 20 von 55 Given: f(x)=A(x)/B(x)=(ax^2 + bx + c)/(dx^2 + ex + f); f(x) has singularities, if B(x)=dx^2 + ex + f=0 (B(x) is zero). The defined range (including boundaries) shall not include singularities (e.g. in the example [1, 2000]) Affected INCA Versions: V6.2.1 and V7.0.0 (checked) and lower versions. Workaround: Change the A2L file so that the valid input range, including boundaries, does NOT include a singularity(1) of the given function. As a result all output values of the function and the boundaries can be calculated and result is within a valid range of ECU (but not infinity). (1) Singularity: see description. ________________________________________________________ Extensions - Compatibility with INCA 7.1.0 EHI #2012403685 EE created in INCA V7.1.0 is indefined in INCA V7.0.0 EHI #328357 Suppress new osci VUIs in INCA V7.0.0 EHI #331076 Enable Import of Supported Objects in INCA V7.0 EHI #336734 Import of VUI having new osci in Sub-VUI ________________________________________________________ Bug fixes EHI #1004542 [WBID2751407788] Walkback when launch experiment environment EHI #1004565 CAN Mon stops calculating trigger conditions and uses wrong timestamps EHI #2010403553 Database does not contain all datasets after repair action Already solved with INCA 7.0.0 HF10. EHI #2011405953 If the background task is activated in CDM, the RAM consumption is high EHI #2012401139 Performance generating measure data files improve d EHI #2012402379 Calibration of Mappings using ES581.3 and CCP speed up shall work together EHI #2012402831 Start of Measuring Monitor from HWC with GPS mouse, resulted in blue screen EHI #2012402835 CCP download and upload memory size does not match Was already solved with INCA 7.0.0 SP8/HF14. EHI #2012402989 Automatically recognition (search for hardware) of HW of 3rd-party CAN - modules extended to all found system types (ES580, ES581, ES590, etc.) EHI #2012403110 [WBID3472338849] System error during INCA session. Follow up of #2012403110 (see HF13): Issue completely solved for another use case than reported. Release Notes INCA V700 HF25.docx Seite 21 von 55 EHI #2012403300 Adaptive maps are not updated EHI #2012403313 When a VAL_BLK is requested during a asap3 session, the asap3.exe crash. EHI #2012403674 Error message "Parsed file does not contain a valid ASAP2 project description" when adding ES1303 + Japanese language Error message appears when adding ES1303 at the hardware configuration window and channel setting tab is also blank in INCA V7 of Japanese environment. (After change the language setting to English, this error does not appear.) EHI #2012403687 INCA hangs when working with a huge datasets in CDM Solved for Win 7 (but currently not for Win XP). A complete solution planned for the next HF. EHI #2012403700 [WBID18069440] WB occurs when adding calibration on a new calibration scenario EHI #2012403738 Calibration change markers is not displayed after download for a single page CCP ECU EHI #2012403872 Adaptive characteristics not updated in INCA experiment after read from file EHI #2012404129 [WBID347956746] while opening experiment due to "Inactives" in the EE (Calibrations and Measurements) EHI #2012404193 Inconsistent CCP command counter received error if starting MPM window after opening EE and finishing initialisation (ES581) EHI #2012404334 [WBID987567384] WB occurs when opening EE with Japanese characters in measurement file path setting EHI #2012404373 Limited ERAM: A MAP should be write-protected if enough ERAM blocks are not available EHI #2012404375 Limited ERAM: A MAP data and axis data should be write -protected if enough ERAM blocks are not available EHI #2012404410 The ECU stops when calibrating a variable which is not located at current "ETK Emulation Rages". Note: Issue (with ETK D&T V3.4.2 and subsequent) is solved with ETK D&T V3.6.0 (also part of INCA V7.0.0 SP9) EHI #2012404415 Calibration outside the hard bounds is possible if the defined range includes a singularity EHI #2012404429 ProF: Flashing failed EHI #2012404508 If an OpenEE-instrument locks INCA, all instruments implemented by OpenEE are no longer served with data. EHI #2012404560 Logviewer not available for Win7 64 Bit EHI #2012404629 [WBID1789765672] INCA crashes when the calculated signal gets "out of range" EHI #2012404712 [WBID3717484010] while opening EE with option "Enable Release Notes INCA V700 HF25.docx Seite 22 von 55 Calibration of Measurements: Yes". WB if User Option "Experiment -> Calibration -> Enable Calibration of Measurements: Yes". Workaround: Enable Calibration of Measurements: No". EHI #2012404724 Communication between INCA and ODX link is f aulty EHI #2012404729 Used display identifier [Display ID] does not show inactive variables in EE All active/inactive variables with the option [Used display identifier] as [YES]/[NO] are now shown. EHI #2012404751 A2L reading: Setting for special encoding will be overwritten. EHI #2012404785 [WBID4293774349] Calibration Scenario Configuration: INCA crash while reading scenario EHI #2012404794 [WBID3202969049] INCA crash while loading an ECU-Project(A2L+Hex) EHI #2012404801 The 2D overlay editor in INCA 7.0 extended with zoom factors New feature for INCA 7.1.0 backported to INCA 7.0.0 EHI #2012404810 [WBID347956746] WB on opening an experiment Same WB like in the call 334777 EHI #2012404858 INCA hangs during XCPonCAN initialization EHI #2012404867 Limited ERAM: If a block(e.g, 0x20000-0x30000) was not emulated in the last session, it is not possible to calibrate a variable on EE. EHI #2012404869 Limited ERAM: If any component of MAP is write-protected, "Ctrl+U" operation should not be possible. EHI #2012404876 [WBID770727733] + [WBID1176513291] Walkbacks in EE when working with Combined Editors EHI #2012405020 Error message in MCD3 V2.2 when creating ASCII-file (MCDWriteReadRecorder.Deaktivate) EHI #2012405155 [WBID2097232047] WB when opening axis from CSV-file EHI #2012405255 Flashing cannot be started because ProF detects an error reading "convert" definition twice. The second "convert" procedure leads to the termination of th e flash process. But the second definition of the "convert" procedure is an allowed use case. EHI #2012405439 MCD3: Measurement are displayed as "0" or invalid measurements in case of remapping of rasters EHI #323593 INCA-MCE: Configuration does not fill open rasters (INCA Part) Note: Solution requires also an update to INCA-MCE V1.1.1 or subsequent. EHI #323971 ES581: TimeOut of CCP commands for USB based devices wrong EHI #324954 INCA - MCE Configuration fails if Japanese characters are in the A2L long name Release Notes INCA V700 HF25.docx Seite 23 von 55 EHI #328316 XCP on USB - New USBIO driver version V2.6 support EHI #329663 [WBID414940203] Potential walkback when virtual calibration measure device is created. EHI #329886 ES720 Unknown Software exception INCA part solved. Requires also an update of ES720. EHI #329934 INCA MCE : A2L with Japanese character fail to proceed fast ECU access. Message display after selecting specific variables, which includes Japanese character in long identifier of MEASUREMENT(or CALIBRATION). Test bed computer could not find ES910.3 and is unable to proceed fast ECU access. EHI #335335 [WBID3730233174] + [WBID1676339687] when opening EE via D BB when HWC is open in parallel EHI #335369 ES720: ER LED on CCP hardware is set after power cycle connected ECU multiple times. Solved in INCA. Requires an update of ES720 as well. EHI #336201 It is not possible to assign a project with ETK -XETK AMP (OHI) to a device (due to MMF error) EHI #336587 [WBID2405776931] WB when open experiment after clear index out of range warnings EHI #336724 MCD3 V1.01: ES650 - device->Set Raster1 failed on LogicalLink EHI #336726 VSD drops an 'System.ArgumentOutOfRangeException' when using the 'already selcted' filter button EHI #336754 SkipWriteProtectedBinaries does not allow to create link with default binary EHI #336923 Slew variable with BIT_MASK is not added properly to the experiment EHI #337059 [WBID2562174221] when open EE EHI #337099 [WBID1454947006] when open EE using Virtual Prototyping Device (X86 PC Controller) EHI #337700 [WBID4129849108] when try to add special label to EE EHI #337996 Timeout / error occurs if start of target server is delayed e.g. due to heavy load on computer EHI #339299 [WBID1222487598] WB reading project EHI #340063 IPM locks up when reinitialize hardware after perform IT update EHI #340720 [WBID847460348] When using Fill With Value in Overlay Mode ___________________________________________________________________ Release Notes INCA V700 HF25.docx Seite 24 von 55 INCA V7.0.0 HF14 Note: INCA V7.0.0 HF13 was not released at the ETAS Download Page due to found side effect: - EHI #2012404482 [WBID2390152117] WB opening EE in case of EE with VUI and HWC changed As of August 24, 2012, it is recommended to install (at the lowest) the products/add-ons shipped with INCA V7.0.0 Service Pack V08: For details read the corresponding release notes, please. Please check the ETAS download center for updated versions. Known issue ============================ Same like with INCA V7.0.0 HF13. Please read carefully. Especially KIR PR 2012404415 (also published on the ETAS Download Center) Bug fixes and improvements ============================ EHI #2012404482 [WBID2390152117] WB opening EE in case of EE with VUI and HWC changed Side effect introduced with INCA V7.0.0 HF13 solved. EHI #2012404149 [WBID3932541479] WB on attempt to open experiment EHI #336435 Possible to have widgets with unexpected names after automatic inactivation from labels ___________________________________________________________________ INCA V7.0.0 HF13 As of July 19, 2012, it is recommended to install (at the lowest) the products/add-ons shipped with INCA 7.0.0 Service Pack V07: For details read the corresponding release notes, please. Please check the ETAS download center for updated versions. Known issue ============================ - ES581.3 ECU Flashing Flash-issues with ES581.3 are not solved completely. It is planned to solve the issue with the next version. - EHI #2012404415 Calibration outside from hard bounds possible if the defined range includes a singularity KIR PR 2012404415 (published on the ETAS DL-center) Release Notes INCA V700 HF25.docx Seite 25 von 55 If within the A2L a COMPU_METHOD with a (possible) singularity (1) is defined (e.g. f(x)=1/x) AND this COMPU_METHOD is used to calculate the hex value out of phy values of a parameter AND the defined range (including boundaries) wrongly includes the singularity of this COMPU_METHOD (here x=0; e.g. a range [0, 2000]) AND the value (hex or phys) of the parameter is changed outside the defined boundaries within the experimental environment of INCA (here: e.g. x= -20) THEN INCA does not detect, that the value of the parameter is outside the boundaries and the value is wrongly transmitted to the ECU. Note: (1)Singularity respectively pole of the function is a point at which a given mathematical object (function) is not defined [e.g. division by zero]; infinity; f(x)=1/x at x=0) Given: f(x)=A(x)/B(x)=(ax^2 + bx + c)/(dx^2 + ex + f); f(x) has singularities, if B(x)=dx^2 + ex + f=0 (B(x) is zero). The defined range (including boundaries) shall not include singularities (e.g. in the example [1, 2000]) Affected INCA Versions: V6.2.1 and V7.0.0 (checked) and lower versions. Workaround: Change the A2L file so that the valid input range, including boundaries, does NOT include a singularity(1) of the given function. As a result all output values of the function and the boundaries can be calculated and result is within a valid range of ECU (but not infinity). (1) Singularity: see description. It is planned to solve the issue with the next version. Bug fixes and improvements ============================ EHI #312025 [WBID550393319] Walkback when read in csv file with wrong format EHI #314344 Suppressing "View Elements" in EE not possible for measurements in MCD3 use case EHI #328391 ES581 - CCP: The progress bar in upload progress window shows more than 100%. EHI #329329 ES581.3 CCP upload fails due to "Inconsistent CCP command counter received" error EHI #330050 ES581 Performance XCP: Recording/visualization stopped after 10Sec EHI #331416 MCD3 MCE Autoconfiguration - AlwaysUseFuli option is now supported for MCD-3MC V1.0.1 und V2.2 EHI #331434 Search in online help locks up INCA if use non-default installation path. Note: Same like #2012403673 Release Notes INCA V700 HF25.docx Seite 26 von 55 EHI #331744 Some slew variables can no longer be displayed in a Measure Window with INCA V7.0.0 EHI #332146 Data reduction delay does not work with pre start trigger time configured EHI #2011400409 Inactive variables get deleted from EE if the window contains only inactiv variables EHI #2012400847 HIL-System: INCA data logging - Window pops during automated I/O-test EHI #2012401221 ProF freezes while flash programming EHI #2012401395 INCA stucks if initializing HW subsequent to a power fail on the ECU EHI #2012401397 Flashing only data with configuration not possible if commands EXTENDED_MESSAGE and DISPLAY_MESSAGE in the [info] section don't have return values. EHI #2012401409 CCP connection break down using ES581.3 EHI #2012401603 No values for 2nd CAN using ES581.3 on different baud rates EHI #2012401611 [WBID1885463622] when adding a new label to the EE EHI #2012402132 Offset on CAN monitoring in dat file if 2 ES581.3 used Same problem like call #2012401374. Solved with INCA 7HF11. EHI #2012402163 Communication breakdown using USB Device on Panasonic CF5x EHI #2012402305 ES580 Puffer goes full during stopped experiment EHI #2012402379 Calibration of Mappings with several cells using ES581.3 leads to communication loss to ECU EHI #2012402409 Flashing over ES581 not successful EHI #2012402501 Add ECU project via COM-API is too slow EHI #2012402761 Flash over ES581 fails with timeout while waiting for a CAN-frame from ECU EHI #2012402803 ES581 CAN - Performance: Delay in transmission EHI #2012402913 [WBID2659564884] occurs repeatable during ASAP3 connection when recording job is started EHI #2012402980 [WBID2942607086] WB if closing ASAP2-Editor window before content is visible EHI #2012403084 Measure Calibrations are calculated from the RP if the calibration page is switched automatically after init to the WP EHI #2012403085 Adding project files via COM-API takes 10 times longer than manual adding the project EHI #2012403110 [WBID3472338849] System error during INCA session (part I) Release Notes INCA V700 HF25.docx Seite 27 von 55 Workaround is to set the option #Strictly increasing#=No Solved for one of the use cases which lead to this WB. Solution for another use case is tracked with call #335271. EHI #2012403164 Escape characters are not interpreted in INCA Monitor EHI #2012403298 ASAM MCD 3MC Error #60217 with command SWITCHING OFFLINE/ONLINE: Calibration can't be turned off EHI #2012403314 [WBID3801010369] system error when working with OHI editor EHI #2012403335 COM_API Error: If the name of the top folder contains a special character it cannot be deleted EHI #2012403370 [WBID1828090018] during long-lasting LCA tests EHI #2012403454 The metadatas of the CDF file are lost during the association of a CDF file with an A2L file EHI #2012403529 COM-API: "SetDoublePhysValue(0)" returns false, although calibration access was successful EHI #2012403568 Log file "SystemInfo.log" is not aded to ZIP EHI #2012403635 [WBID579070364] While open a HTML File in CDM a WB occurred EHI #2012403662 Comment of the measurement file has "%H" in the time setting instead of a value EHI #2012403673 Inca crashes on online help search Same like #331434 EHI #2012403684 [WBID1126647506] Initialize Experiment causes WB EHI #2012403704 [WBID1126647506] Walkback during the experiment opening EHI #2012403724 Connection loss to ES593_D CCP Driver EHI #2012403731 There is no symbol showing characteristics dependency in CDM EHI #2012403745 HSP: Targetserver failure during CCP session over ES593 Solved with HSP V9.7.0 EHI #2012403802 HSP: CCP values are missing over ES593 Solved with HSP V9.7.0 EHI #2012404096 [WBID6660969] in the ASAP2 editor if attempt to extend dependent variable view EHI #2012404207 Checksum calculation interrupts dyno cycle with Asap3/CCP Note: Issue was already solved with HF11 (#2011409016) EHI #332119 Serial number range for ES581.3 for recognition as ETAS device extended EHI #332586 No ETK index is available in HWC if ES1232 is used with XAML ECU project EHI #333604 Walkback when trying to delete an [undef] experiment from INCA V7.1 Release Notes INCA V700 HF25.docx Seite 28 von 55 EHI #335346 ES720 Software exception due to invalid UTC time received from the GPS mouse sporadically EHI #331129 IP Manager: ES5xx device receive more than one IP address resulting in disconnections EHI #331384 ASAP3: Crash on SelectLookupTable after failed SelectDesAndBin EHI #331455 [WBID784145778] when try to delete a INCA V7.1 experiment EHI #335389 INCA 7 HF13beta2: Output-file after compare is empty EHI #97244 Known Issue PR 253197 (#97244): System becomes very slow, if running ES910 is disconnected If an ES910 is disconnected during a running EIP experiment, the INCA user interface becomes very slow. EHI #101150 ASAP3-Recorder: GetRecorderResults returns error if recorder file contains labels with CompuMethod "Verbal" EHI #312004 IncaDataBase.ImportFromFile() fails if option "import in selected folder" is active EHI #327825 With the ASAM MCD3 MC v2.2 Testclient it is not possible to delete the logical Link EHI #330057 Copy and paste value into VTab Scalar does not work with enumerations EHI #330653 [WBID2797344315] LCO - integration test: An error window appears during ECU measurement tests EHI #331191 GPS hardware configuration issue with GPS workspaces - signals listed twice EHI #334311 [WBID753788609] during replace system in HWC EHI #334629 MCD3 Test-Client opens the wrong INCA Version (V7.1.0) EHI #334675 J2534 - TestBlocking System Exception at initialization HW EHI #334884 ProF Flashing: Tgtsvr stops working on flashing WP->ECU via UDS from KWP device. Side effect of #2012401221 ___________________________________________________________________ INCA V7.0.0 HF12 Known issue ============================ No new issues. Bug fixes and improvements ============================ Known issue of HF11 solved: EHI #332207 Delay in start measurement of CAN Values Release Notes INCA V700 HF25.docx Seite 29 von 55 ___________________________________________________________________ INCA V7.0.0 HF11 Known issue ============================ See HF12: EHI #332207 Delay in start measurement of CAN Values Therefore HF11 was never published on the ETAS download page. Bug fixes and improvements ============================ EHI #94408 ASAM MCD 3MC Editor: Problems with help menu EHI #99128 Variables are selectable, even if the performance calculation disables these variables EHI #100263 J2534 ES581: Baudrate 1MBaud initialized but not supported EHI #2011405072 LAB file not usable EHI #2011405074 Write out of LAB File ignores entry .Output EHI #2011407108 Asynchronization in the ASAP3 communication. EHI #2011407945 [WBID902711056] System error while repairing the database. EHI #2011408030 The IP Manager pops up at corporate network connection and asks for reconfiguration EHI #2011408422 Logical signals are not correctly interpreted and displayed in the experimentation EHI #2011408717 Experiment does not work on ES720 due to high RAM usage EHI #2011408981 No information about lost ES581 device with CAN-Monitoring. EHI #2011409016 Adjustment of checksum interrupts test bench cycle EHI #2012400248 Downloadig data to the WP fails with an ES581.3/CCP device EHI #2012401091 Experiment require too much RAM for ES720 EHI #2012401374 Timeshift in the Recording if two ES581.3 used in the HW configuration EHI #2012401376 Inconsistent CCP command counter EHI #2012401382 PC hung up during INCA session using ES59x devices. EHI #2012401385 EIP 7.0.2 [WBID2700811984] (ExCPMStackOverflow) A stack overflow has occurred. EHI #2012401394 The warning "DAQ_MODE_ALTERNATING" occures instantly in the experiment. INCA V6 showed the information only once. Release Notes INCA V700 HF25.docx Seite 30 von 55 EHI #2012401408 While work with Database repair Win XP generate a error message. EHI #2012401491 [WBID1727672009] due to wrong CAN DB definition files Solution: Prevent reading CAN DB files with wrong definitions. EHI #2012401568 [WBID4190502864] occurs sporadically when a label was inserted to the experiment EHI #2012401613 Read ECU ID fails if ECU sends the ASCII character % (0x25) EHI #2012401868 Japanese description in the Path Selection dialog (ProF installation) is garbled EHI #2012401908 [WBID2380438454] System Error performing HPT with reimport EHI #2012401910 Incomplete IPMD file of ES581.3 is not being validated on ES720 due to missing CAN monitoring EHI #2012402165 INCA-FlexRay: INCA can't read FIBEX V3 file Note: Update to INCA-FlexRay V7.0.3 required. EHI #2012402412 [WBID247455946] Exception is not resumable EHI #2012402628 CCP download is not Optimized EHI #2012402751 [WBID2780797359] and [WBID793658695] during long-lasting LCA tests EHI #2012402806 EW_I700: [WBID2700811984] when assigning INTECRIO project to ES910 EHI #2012402817 Error message when analysing the database EHI #2012402820 [WBID852245266] INCA Crash when adding Etarget project EHI #2012402895 Upload with ES581.3 (CCP) is not possible CCP command counter received - Inconsistent EHI #311692 [WBID138734720] Walkback on MCD3 look: EHI #326037 [WBID4129289469] (ExCPMStackOverflow) A stack overflow has occurred. EHI #328178 XETK: Incorrect display of serial number of XETK in HWC EHI #328286 Monitor message for experiments with new INCA V7.1 oscilloscope in older INCA versions EHI #328290 Hotfix to prevent import of *.ee files with new INCA 7.1 oscilloscope into INCA V6.2.1 and V7.0 EHI #328297 Getting Unexpected Error Message when Copy and Paste VTab Value with Data Representation = "Hex" and Conversion Method has a Default Value and label is used in Combined Editor EHI #328557 [WBID3892241955] Walkback encountered when reading in hex file EHI #328821 No filter for slewable variables in VSD Release Notes INCA V700 HF25.docx Seite 31 von 55 EHI #328858 INCA does not allow calibration of all values when all calibration handles are used EHI #329086 Getting Unhandled Exception when try to select Measure Array / Matrix in VSD EHI #329098 ASAP3: [MemoryAccessError]: Command Get Recorderresult Header -> ASAM MCD 3MC 4 INCA -> Memory Access Error EHI #329384 Project files take a long time to load EHI #329416 CAN, CCP Switch off / on ECU has at least no measurement EHI #329846 Backport of INCA 7.1.0 OCD ES581 solution for INCA 7.0 EHI #329909 ASAP3: Command "Get Recorder Results" returns "Invalid Measurement" with temp ASAP3.dat EHI #329910 ASAP3:Command "Define Recorder Parameter" failed if the wrong Datatype is used for the registrievalue "UseRasterCheckForMeasurement" EHI #329912 ASAP3_: Unknown Error ASAP3.exe at Command "PARAMETER fOR VALUE ACQUISITION" EHI #331002 INCA-EIP (INCA 7.0.0 part) Performance: There is first a "Verify WP and RP", than a FW check, and than again a "Verify WP and RP" Performance improvement for the upcoming INCA-EIP 7.0.3 Note: INCA-EIP 7.0.3 is requied. ____________________________________________________________________________ INCA V7.0.0 HF10 Known issue ============================ See KIR issue solved Bug fixes and improvements ============================ KIR issue solved: EHI #2012401578 Differences in CDM not detected if data exchange files are used for compare If INCA CDM is used for compare AND two data exchange files are used for compare AND the CDM "Compare" option "Use Precision for Compare" is set to "for data exchange files only" AND the INCA "User Option" "Data exchange" "Maximum precision" is set to "from ASAM-2MC file" AND Release Notes INCA V700 HF25.docx Seite 32 von 55 the CDM "Compare" option "Compare Mode" is set to "tolerant" OR "tolerant bi directional" AND Parameter of type VAlBlk is used AND No other type of parameter is compared before compare of a parameter of type VAlBlk AND Both parameters are >= 1 AND the difference between the parameters is smaller than 50% THEN there is no difference detected (wrong behavior) Note: Independent of the issue: Compare of address values should not be done in tolerant mode (but "exact"). Affected INCA Versions: INCA V6.2.1 and INCA V7.0.0 Solved with INCA V6.2.1HF31 and INCA V7.0.0HF10 EHI #100970 Number of Repetitions is not written to Comment s anymore EHI #312023 MIP not working with IncaGetRecords command EHI #323990 [WBID1588301702] Switching projects causes walkback when opening experiment EHI #326130 MCE configuration is carried over to new experiments EHI #326801 ASCET model in INCA-EIP causes ethernet disconnection error EHI #327012 Repeated "FullScan" parsing of INCA data base via MCD 3 leads to lack of accessable memory EHI #327012 "Deliver Project" via EE adds additional entry in A2L file EHI #327145 [WBID4249392081] when deleting an ASAP2 project EHI #327693 Rescale Axis issue with Reset to "Reset to Reference Page Value / Complete Map" EHI #327727 [WBID2886875596] when switching CDM compare option in CDM and label of type VALBlk is calibrated in label editor EHI #327750 After renaming Trigger Channel of ES1303 the Trigger is removed from the Experiment EHI #327805 [WBID4229974805] in CDM occures when file is linked to ASAP2 project in CDM EHI #328053 [WBID849430863] when dataset is removed from CDM source EHI #328529 The connect to ASAP file feature does not transfer the variable type attribute EHI #2011402222 [WBID1890870391] when using "Freeze working Dataset" command in Experiment Environment EHI #2011403940 Measurement window changes background colour Release Notes INCA V700 HF25.docx Seite 33 von 55 EHI #2011404284 DB is growing working with same workspace EHI #2011407670 Boolean labels can not be used with INCA-MCE EHI #2011407754 [WBID94158247] System Error during recording EHI #2011408016 Problem of communicaton with XCP on Ethernet using VECTOR vx1110 device EHI #2011408018 Not possible to add a2l in INCA 7.0 EHI #2011408777 Repeated moving action of variables in a table editor window parameters leads to corrupt window content EHI #2012400748 Address extension in CCP SET_MTA is not sent correctly if ES59x is used EHI #2012400909 [WBID1588301702] System error when opening EE EHI #2012401344 Gaps in measurement with ES595 EHI #2012401411 Recorder values are incorrect EHI #2012401612 Failed to start ECU documentation with Acrobat X - supported with HF9ff EHI #2012402203 Dependent parameter calculation results in a false value ____________________________________________________________________________ INCA V7.0.0 HF9 Known issue ============================ Known issue with ES9xx Add-on V7.0.3 and INCA-EIP V7.0.1 of INCA 7.0.0 SP1 is solved with INCA 7.0.0 SP2 and following. New features ============================ EHI #2012400694 ECU Docu Interface: Support of Acrobat X Bug fixes and improvements ============================ KIR issue solved: EHI #2012400625 CAN Monitoring measure values might be not visible and not recorded If INCA 6.2.1HF15 to 7.0.0HF8 is used OR the corresponding ES7xx versions (ES715v6.2.1/SP5; ES720v7.0 all versions) AND CAN-monitoring measurement/recording is executed AND HW is running longer than 71.3Min AND Measurement is stopped (via "Stop Measuring (F9)") for a period of longer Release Notes INCA V700 HF25.docx Seite 34 von 55 than 71.3Min (Recording "Pause" is not affected) AND Measurement is restarted again THEN CAN-monitor measurement is stopped / halted without any further information (no warning, no error message etc.). --> Experimental Environment: no further update are made (always the same value displayed); Not applicable for ES7xx --> Recording: measurements are no longer written into file. Note: There is no defect if the measurement is not stopped. KIR issue already solved with INCA 7HF8: EHI #2011407162 CAN-Monitoring: Buffer full error displayed by mistake If INCA 7.0.HF4 to HF 7 is used AND HW integrated via BOA is used: ES520, ES580, ES511, ES910, ES921, ES592, ES593, ES595, Vector CANcardX, CANcardXL, CANcardXLe, CANcaseXL and VN7600 (not affected: ES715, ES581.x, ES590, ES690, ES1222) AND measurement is executed via CAN AND high bus load, slow computer, experiment with high number of measurement items, THEN an error indicating that the "buffer is full" and that the measurement should be aborted, may be erroneously displayed Note: - User is informed (via error message) that buffer is full and that the measurement should be aborted. But, measurement and error handling in the case of a real buffer overflow is not affected. - Solved with INCA 7HF8. But displayed buffer filling level is still only a rough indication. KIR Issue finally solved: EHI #2011402280 Working point is saved wrongly in the measure file - and working point display Display working point also with affected projects on demand EHI #2011405167 [WBID754229532] with array's solved EHI #2011405395 [WBID1841638718] Importing attached file with the option: Import into selected folder EHI #2011405655 Measure file from ASCET V5.2.2 is wrongly interpreted Release Notes INCA V700 HF25.docx Seite 35 von 55 EHI #2011405773 Two ES1303, each in a different ES1000, not usable EHI #2011407162 CAN-Monitoring: Buffer full error displayed by mistake EHI #2011407636 The Description information to a measurement signal in measurement files is not available EHI #2011407755 [WBID2746652332] while inserting new variabnle in the EE EHI #2011408059 A large measurement file, recorded with INCA V7.0.0 and with empty data groups, can not be used with MDA V7.0.0. EHI #2011408066 Disturbing output in control flow monitor EHI #2011408223 [WBID3465117962] when exchanging the axes EHI #2011408254 ASCII-Files cannot be used in MDA EHI #2011408758 [WBID1268797178] if attempt to start EE EHI #2011408778 [WBID4182064724] after ToolAPI command GetScenarioNames EHI #2011408813 Package information from Log-files and "Loaded packages" does not correspond to each other EHI #2011408977 CDM QM-Basic entries are lost when XML file is removed from "Destination" EHI #2012400105 A2L generator loses ETK version and type EHI #2012400310 [WBID579070364] in CDM if preview of MAP or table started with STRG+W EHI #2012400416 Not possible to establish ASAM3MC3 session with MCE Ethercat labels EHI #2012400694 ECU Docu Interface does not work with certain path name (...\xxxx.pdf\...) and support of Acrobat X EHI #2012400972 "Error" message in INCA-EE EHI #2012400979 Read checksum from .chk file does not work while flashing ECU EHI #2012401117 After ETK hardware initialization an automatic download occurs without popping up of the memory page window EHI #311184 INCA Crash During Morphee "Full Scan" EHI #311805 [WBID2635661307] during database access EHI #311808 [WBID776998434] EtasGenericHWItemSystemVersion3 does not understand checkVerification EHI #323807 Wrong result for XCPX_UNLOCK Command in PROF EHI #323896 No connection to ETAS hardware with Win7 if initialize before connect hardware EHI #323914 No blockmode flashing with XCP possible if the ECU doesn`t Release Notes INCA V700 HF25.docx Seite 36 von 55 support blockmode UP/DOWNLOAD EHI #324324 Recording appears to update periodically instead of constantly with oscilloscope in configuration EHI #324987 [WBID2879276672] after reading data exchange file via EE datasets read calibrations from file EHI #325868 INCA - ALIGNMENT for RESERVED in RecordLayout EHI #326406 Exception in ASAM MCD 3MC 4 INCA 2 Module when connecting to INCA by the MCD3 Client EHI #326407 Logical Links for FULI will not be listed if optimization options are set ( PROD77119 & PROD82279) EHI #326539 [WBID3508097936] after compare to ASCII in CDM EHI #326727 [WBID467667205] when open old Display Configuration EHI #326729 CDM shows error icon on all labels when DCM file linked to ASAP2 Project EHI #326745 TgtSvr leaking memory at HW-Init EHI #326858 ES581 CAN Monitoring timestamps are not correct ____________________________________________________________________________ INCA V7.0.0 HF8 Known issue ============================ The ES9xx Add-on V7.0.3 has to be installed after the INCA-EIP V7.0.1 installation to achieve correct functionality for the complete chain. (This is automatically respected if updated via Setup_ServicePack.) The upcoming INCA-EIP V7.0.2 solves this issue. New features ============================ EHI #2011400945 INCA support of CAN extended with 50.000, 666.666, 800.000 Baud INCA support of CAN was extended with 50.000, 666.666, 800.000 Baud rates for the following hardware. Hardware - Required Product/AddOn ---------------------------------ES511 ES5xx AddOn V7.0.2 ES592 ES5xx AddOn V7.0.2 ES593 ES5xx AddOn V7.0.2 ES595 ES5xx AddOn V7.0.2 ES910.2/.3 ES9xx AddOn V7.0.3 ES921 ES9xx AddOn V7.0.3 ES580 INCA V7.0.0 HF8 ES581.2/.3 INCA V7.0.0 HF8 ES520 INCA V7.0.0 HF8 Release Notes INCA V700 HF25.docx Seite 37 von 55 This requires an update of the corresponding INCA products/add-ons contained in INCA 7.0.0 Service Pack 01 EHI #325761 Support Service Packs - Setup Service Pack to install the INCA HF and the recommended INCA Add-Ons A - service pack (SP) is one single ZIP file containing Latest INCA hotfix Latest version of related Add-ons Installation routine, which automatically installs the hotfix and updates the add-ons installed on the users PC For more details see INCA Introduction of Service Pack (SP).pdf shipped together with the first SP Bug fixes and improvements ============================ - KIR Issue solved EHI #2011402280 Working point is saved wrongly in the measure file. EHI #100866 [WBID3465117962] WB solved EHI #100869 [WBID1858677281] Several WBs with same ID solved EHI #101087 [WBID3862466148] WB solved EHI #101290 ES581: ECU connection lost after stop Measurement using two ES581 on the same time EHI #1004566 [WBID667152105] Walkback when perform CDM copy with Copy curves and maps set to Expand EHI #1004568 ES581 communication drops out during measurements EHI #2011400945 INCA support of CAN extended with 50.000, 666.666, 800.000 Baud EHI #2011402280 KIR Issue solved: measure file. Working point is saved wrongly in the EHI #2011403190 XCP-issue if a CAN-monitoring is in use EHI #2011404115 Misleading warning after raster mapping EHI #2011404483 Checksum calculation with ES581.3 during every start -stop of Experiment EHI #2011404544 Inconsistent behaviour with equal measurement names EHI #2011404726 INCA re-initializes ECU connection after measurement stop EHI #2011404853 Bit is wrongly displayed in yt-ocilloscope EHI #2011406256 Walkback while reading cdfx file generated by EESY Release Notes INCA V700 HF25.docx Seite 38 von 55 EHI #2011406408 CDM- Action-List shows a names of parameters in wrong sequence. EHI #2011406855 Identical conversions get listed as differences EHI #2011406955 Type and version information of ETK_MAILBOX as defined by ASAP2 are missing after regenerating A2L EHI #2011407121 INCA 7 generates faulty MDF4 files EHI #2011407159 [WBID628375818] INCA crashes after comparing in CDM EHI #2011407162 ES580 buffer goes full during CAN-Monitoring EHI #2011407253 Value matrix nx1 not identified as valueblock EHI #2011408065 Background color of measure table changes EHI #2011408149 Not possible to start recording with attached EE if using an XETK aml for an ETKT2 EHI #2011408223 [WBID3465117962] WB solved. EHI #2011408421 Missing functionality for sorting parameter by function in CDM EHI #99185 Calls 92278, 95153 and 92768 solved EHI #311798 [WBID3244425468] WB solved EHI #312531 Wrong DAQ assigned after multiple reconfiguration EHI #322966 ES581 not works with CCP,UDS,KWP and XCP EHI #322969 [WBID3401309891] WB solved EHI #323258 CAN_MON first timestamps at CAN Monitoring are incorrect EHI #323302 ES581 CAN Monitoring via CAN1 and 2 with different baud rate has at start measurement no correct values EHI #323313 Timestamp Jumps on DaisyChain Devices connected on ES592 EHI #323339 ES581 CAN1 Monitoring has negative timestamps if CAN2 is used with KWP EHI #323374 Multiselect with Shift an Scroll in Display Configuration EHI #323388 ES581 CAN Monitoring Port disconnected during reinit HW EHI #323413 Wrong description in CDM online help EHI #323606 Backport Full Scan related Filter Options (PROD77119 & PROD82279) EHI #323932 No XCP Flashing possible if Init fails in INCA EHI #323973 Initialize CAN-Monitoring during start experiment fails EHI #323977 Possible that label with different values are shown as grouped EHI #324036 INCA-MCE V1.1: Support upload axis points Release Notes INCA V700 HF25.docx Seite 39 von 55 EHI #324361 ES581 Multi Client Backport: Second client terminates INCA communication EHI #324406 ES581 Multi Client Backport: INCA display no error message on access the Port as second client with other settings EHI #324416 INCA-MCE UploadAxisPoints: Number of axis points can be changed via API EHI #324554 Help for 3rdParty Hardware for INCA V7.0 updated EHI #324587 ImportExportHexFiles: ECU project not read in correctly any more EHI #324641 ES910.3, ES921: Lost of communication during measurement XCP EHI #324675 New Baud rates with ES520: Init XCP with 50 kBaud shows access violation EHI #324691 KWP2000 on CAN implementation for RENAULT NISSAN EHI #324829 [WBID144291448] WB when try to change multi selected Output Values in Combined Editor via F2 EHI #324846 [WBID1449895592] WB after List Action EHI #324847 [WBID1511931280] WB when opening CDM config EHI #324860 New Baud rates 800K CCP: New Commando for CCP does not work EHI #324935 CDM: List to CDFX incorrect - empty