Remote Control Unit
KLASSE
PRCU 12
English
CLASS
GSS Grundig SAT Systems GmbH Beuthener Strasse 43 D-90471 Nuremberg
Phone: Fax: E-mail: Internet:
+49 (0) 911 / 703 8877 +49 (0) 911 / 703 9210
[email protected] http://www.gss.de
Contents 1 Safety regulations......................................................................................................3 2 General information..................................................................................................3 2.1 Packing contents...........................................................................................3 2.2 Meaning of the symbols used.........................................................................3 2.3 Technical data..............................................................................................4 2.4 Description..................................................................................................5 2.5 PC / laptop system requirements....................................................................6 3 Installation................................................................................................................7 3.1 Installing the management system...................................................................7 3.2 Assembling connection cables........................................................................8 4 Connecting components.............................................................................................9 4.1 Connecting the basic units.............................................................................9 4.2 Connecting a PC/Laptop...............................................................................9 4.3 Connecting a PC/Laptop via a modem...........................................................9 4.4 Connecting a PC/Laptop via Ethernet.............................................................9 5 Installing the software on a PC or laptop..................................................................10 5.1 Key number (activation code) for the software................................................10 5.2 Installing the software..................................................................................10 6 Operating the Software...........................................................................................12 6.1 Configuring the management system.............................................................13 Configuring the management system via direct connection "Com"....................15 Configuring the management system via "Ethernet"........................................16 6.2 Connection establishment at configured basic unit..........................................17 6.3 Alarm messages via SNMP traps..................................................................18 7 Software update via the BE-Flash software...............................................................20
- 2 -
PRCU 12
1
Safety regulations • Assembly, installation and servicing should be carried out by authorised electricians. • Observe the safety regulations and notes in the assembly instructions for the cassettes and head-end station used as well as the relevant safety instructions e.g the standards IEC/EN/DIN EN 50083 and IEC/EN/DIN EN 60728. Take action to prevent static discharge when working on the device!
2
General information
2.1
Packing contents
1 1 14 2
1
Expert Power Control NET 8X – mains cable (multiple extension lead switchable via ethernet) 8 IEC-320 AC power cordsets 1 m 15 RS-232 plugs ( 9-pin Sub D ) 15 RS-232 sockets ( 9-pin Sub D ) 1 9-pin ribbon cable ca. 30 m 1 CD (Software PSW 1000 and Assembly Instructions)
2.2
Meaning of the symbols used
MOXA ThinkCore DA-662 Linux PC - mains cable 19" panel RJ45 to RS232 network cables 60 cm network cables 2 m
Important note
—>
General note
•
Performing works
- 3 -
PRCU 12
2.3
Technical data
The devices meet the following EU directives: 2006/95/EC, 2004/108/EC The product fulfils the guidelines and standards for CE labelling.
Implemented Simple Network Management Protocol for GSS basic units: The following items are signalled: – Level of the output signal measured via PSCU 6000 – BIT – error rate at QAM output signals – Present line synchronizing signal at analogous PAL output signals – Present RDS signal at FM output signals – Quality of the input signal (good, poor and no signal) at QPSK-PAL double transmodulators as well as QPSK- QAM transmodulators
Remote software updates: – Software updates are done via the BEflash software. – Remote software updates are possible at all current Profi Line basic units.
Remote software update at following components:
BE-Remote PRCU 12
Remote update is possible from version V37 on Remote update is possible from version V 1 on
PSAP x000 PTAP x000 PTFF 2000 PTAF 2000 PSDQ x000
Update Update Update Update Update
PHDQ x003 TPS PSDQ x003 TPS PHDQ x002 BC PSDQ x002 BC PSDQ x004 MX
Remote update is possible from version V10/V17* on Remote update is possible from version V10/V17* on Remote update is possible from version V10/V17* on Remote update is possible from version V10/V17* on Remote update is possible from version V10/V17* on * FPGA part
PSDP x200 PTDP x200
Remote update is possible from version V15 on Remote update is possible from version V15 on
is is is is is
done done done done done
- 4 -
via via via via via
the the the the the
update update update update update
of of of of of
the the the the the
control control control control control
unit unit unit unit unit
PRCU 12
PSDF 2000
Remote update is not possible at the moment
PSCU 6000 PTDP x000 PSDP x000 PSRF 2000
Remote Remote Remote Remote
Required index levels for remote updates: PSW 1000 index level: V22 BeFlash index level: V30
Note on transmodulator cassettes PxDQx002BC with MTP functionality: When performing a service drop via remote or Ethernet all PIDs of the service which should be dropped and the corresponding PMT-PID must be dropped after selecting the related cassette in the PID drop list of PSW 1000. Then the related tables will be automatically adapted by the activated PSI/SI processing. Up to 10 services can be dropped at transmodulator cassettes PxDQx003(001) by changing the "+" symbol at the listed services to "-" in the corresponding submenu of the virtual control unit of the PSW 1000 using the buttons. The service drops are DVB conformable.
2.4
Description
Hardware concept:
update update update update
is is is is
possible from version V16 on not possible !! not possible !! not possible !!
PRCU 12
ACHTUNG! Vor dem Kassettenwechsel unbedingt denNetzstecker ziehen.
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
0°
Moxa DA 662
AUSGANG max. 90 dBµV
CAUTION! Before changing cassettes remove mains plug.
RS232 Panel
Grundig SAT Systems
Router
PC
ACHTUNG! Vor dem Kassettenwechsel unbedingt denNetzstecker ziehen.
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
0°
AUSGANG max. 90 dBµV
CAUTION! Before changing cassettes remove mains plug.
Internet
Grundig SAT Systems
ACHTUNG! Vor dem Kassettenwechsel unbedingt denNetzstecker ziehen. CAUTION! Before changing cassettes remove mains plug.
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
KASSETTE
0°
AUSGANG max. 90 dBµV
Power Control NET 8x
Grundig SAT Systems
Rosa System
- 5 -
PRCU 12
The PRCU 12 management system is equipped with the MOXA DA-662 industrial PC which is to connect to the internet via a router, a 19" connecting panel and LAN controlled 230V switching outlets. It has 12 interfaces to control up to 12 control units BE-Remote, the PSCU 6000 monitoring cassette or the backup system PRS 16/8. The units will be connected to 12 Sub-D connectors located at a 19" panel. The Sub-D plugs are connected by RJ45 cables to the interfaces on the rear side of the MOXA PC. In addition a Sub-D socket to connecting a PC and a Sub-D plug to connecting a modem are located at the 19" panel.
Error messages from the PSCU 6000 monitoring cassette can be forwarded by the PRCU 12 management system as SMS, fax or e-mail. Using SMS or fax transfer an analogous modem must be connected which must support SNMP.
The basic units can be configured and remote controlled with software PSW 1000, a remote controlled software update of the cassettes can be done with software BE-Flash.
A connected backup system PRS 16/8 can be configured by the software PSW 1000 via the PRCU 12.
Expert Power Control NET 8X is a LAN controlled 230V 8-fold switching outlet with timeshift switching on of the outlets at power blackout. As the basic units are operated via this power supply unit a remote controlled hardware reset can be done.
It is also suggested to operate the PRCU 12 via the Expert Power Control NET 8X. In this way a remote controlled reboot is possible.
2.5
PC / laptop system requirements
System requirements for the supplied PSW 1000 software: – PC or laptop with a Pentium processor, – Windows 95*/98*/ME/2000/Vista (*from Internet Explorer 5 on), – At least 32 MB RAM, at least 50 MB free space on hard drive, – CD-ROM drive, – Serial interface (RS-232 D-SUB socket) For PCs / laptops with a USB connection (and without a serial interface), please use a standard USB / RS-232 adapter.
- 6 -
PRCU 12
3
Installation
3.1
Installing the management system
1
1
14
13
12
11
2
3
4
2
10
5
6
7
3
9
8
9
4
8
10
11
5
7
12
13
6
5
14
6
4
3
2
1
15
7
8
9
10
13
14
11
12
• The most proper position to install the Moxa DA662 PC is the top position in the 19" cabinet in which the basic unit is installed. Attention: Ensure that the management system is adequately ventilated! • Right below install the 19" panel "RJ45 to RS-232". • Connect the "control unit connectors" (connectors 1 – @) at the rear side of the Moxa PC to the RJ45 sockets (connectors 1 – @) of the 19" panel via the 12 supported network cables. • Connect the "modem connector" # at the rear side of the Moxa PC to the RJ45 socket # of the 19" panel via a supported network cable. • Connect the "PC connector" $ at the rear side of the Moxa PC to the RJ45 socket $ of the 19" panel via a supported network cable. • Connect the router to the LAN1 socket % at the rear side of the Moxa PC via the supported network cable (2m). —> The sockets LAN2, LAN3, LAN4 and Console are not used. • Install the 8-fold "Expert Power Control NET 8X" switching outlet at a free space of the 19" cabinet and connect it via the supported network cable (2m) to the router. Use the 8 supported power cords to connect the units to be switched to the power control.
.
- 7 -
PRCU 12
3.2
Assembling connection cables
External components are connected to the management unit with 1:1-RS-232 cables. You can assemble these cables in the required lengths by using the supplied RS-232 plugs, RS-232 sockets and ribbon cables. 9
9
5
5
1
1 6
1:1- RS-232 cable
Plug
Socket
• Cut off a section of cable to the required length. • Insert the ends of the cable into the openings on the RS-232 plug and RS232 socket, making sure they are pushed in all the way. • Firmly close the sliders on the blade contacts.
6
- 8 -
PRCU 12
4
Connecting components
4.1
Connecting the basic units
• Connect the RS-232 sockets of the control units using the self-made 1:1-RS232 cables to the RS-232 plugs 1 – @ at the front side of the 19" panel (page 7). • Connect the RS-232 socket of the PSCU 6000 monitoring cassette using a self-made 1:1-RS-232 cable to one of the RS-232 plugs 1 – @ at the front side of the 19" panel (page 7).
4.2
Connecting a PC/Laptop
• Connect the serial interface of the PC using a self-made 1:1-RS-232 cable to the RS-232 socket "PC" $ at the front side of the 19" panel (page 7). Optionally use a commercially available USB/RS-232 adapter at PCs / laptops with USB interface (without serial interface). 4.3
Connecting a PC/Laptop via a modem
The basic units connected to the management system can be configured remotely using a modem and a PC or laptop. Please find our analogous modem set on our webside “www.gss.de”.
• Connect the supported connection cable to the plug "MODEM / MOBILE PHONE" # at the front side of the 19" panel (page 7). • Connect the modem to a phone socket via a phone cable.
4.4
Connecting a PC/Laptop via Ethernet
For the first configuration the PC or laptop must be connected directly to the PRCU 12 (19" panel) as described in point 4.2 (RS-232 connection).
In situ operation of the PRCU 12 should be done via port 3 of the Cisco router 876 by DHCP.
To set the IP address of the router in the menu "Station data" of the PSW 1000 at the first configuration connect the PC/laptop to port 3 of the router and identify the IP address of the router.
- 9 -
PRCU 12
5
Installing the software on a PC or laptop
5.1
Key number (activation code) for the software
A key number is required for the activation of the PSW 1000 software. This can be obtained from your regional authorised distributor.
5.2
Installing the software
• Insert the enclosed CD in the appropriate drive of the PC / laptop. • Unzip the file “SETUP_PSW1000_Vxx.zip” located in the “Software/Fern/” directory on the CD and start the “setup_PSW1000_Vxx.exe” programme by a double click.
• Select the desired language “German”, “English” or “Français” and click the OK button to confirm.
• When the “Setup-PSW1000” menu appears, click the “Next >” button.
• Read the license agreement. • Select “I accept the agreement” and click the “Next >” button.
- 10 -
PRCU 12
• A table will appear which lists the software versions of the cassettes which are compatible with the PSW 1000 software.
Caution: After installing the PSW 1000 software, update the software for the cassettes if necessary.
• Click the “Next >” button.
• Specify the directory in which the PSW 1000 should be installed (e.g. C:\Programs\GSS\PSW1000).
• Click the “Next >” button. • Enter a name for the shortcut to the program which will be created in the start menu. • Click the “Next >” button.
- 11 -
PRCU 12
• Click on “Install” in order to proceed with the installation of the program, or on “Back” to make corrections or changes.
- 12 -
PRCU 12
6
Operating the Software
This describes only the entry in operation of the software PSW 1000 via Ethernet. The operation of the software PSW 1000 is described in the help file which is included in the software. For the first configuration the PC or laptop must be connected directly to the PRCU 12 (19" panel) as described at point 4.2 (RS-232 connection). A key number is required for the activation of the PSW 1000 software. This can be obtained from your regional authorised distributor.
Click the "OK" button when entered the 25 pin code (if more than one pc user need access to the software the pin must be entered for every user).
6.1
Configuring the management system
• Activate the submenu "Plant setting" by clicking the the menu "Edit"/"Plant setting".
- 13 -
button or selecting
PRCU 12
• Activate the pull down menu PRCU/HRCU in the "Station data" area and select "PRCU 12" (otherwise there is no access to the Ethernet settings).
• Enter the IP address which is needed to get a connection to the router from the internet in the field "Phone number of the plant" in the "Station data" area. —> Therefore you either need a "fixed", "static" external IP address, or you need to check the external IP address of the router before every remote maintenance via respective providers of dynamic DNS services (e.g. DynDNS.com). • Enter the port address behind the IP address separated by a colon. Via this channel the router communicates with the PRCU 12. —> For remote maintenance via internet "Port Forwarding" must be configured at the router.
• Enter any text for identifying the basic unit in the fields "Location of the plant" and "Street of the plant". —> In case of an alarm message by the PSCU 6000 this text is transmitted in the error log.
• Activate the check box " PSCU 6000 available" if a PSCU 6000 is present in your plant.
• Activate the menu "PRCU 12 Ethernet" in the window "Plant settings".
• Enter the IP address which the PRCU 12 shall get in your network (router) in field "IP address" in area "Settings".
- 14 -
PRCU 12
—> Use a free IP address of the static IP range of your network (router).
• In addition enter the port number (field "Port:"), the subnet mask (field "Mask:") and the IP address of the gateway (field "Gateway:"). This settings depend on the network and the router.
• Click on the button "Settings Take over".
—> The Ethernet password should be changed after the first configuration is done. The default password is "Grundig".
In the appearing menu "Connection settings" in area "Choice" you can select between: – "Com" for a "direct" connection with a PC (via RS-232 connector), – "Modem" for remote maintenance via modem and – "Ethernet" for remote maintenance via Ethernet.
- 15 -
PRCU 12
Configuring the management system via direct connection "Com"
• Select "Com" and set the corresponding COM interface in area "Settings".
• Connect the serial interface of the PC or laptop to the "PC connector" (RS-232 socket, page 7) of the 19" panel.
• Click the "OK" button.
The window "Connection will be activated" appears, the settings will be transmitted and after that the PRCU 12 will be rebooted.
• Click the "OK" button.
- 16 -
$
PRCU 12
Configuring the management system via "Ethernet"
• Select button "Ethernet" and enter the corresponding IP address and port.
IP address 192.168.0.123 and port 60003 is the default setting of the PRCU 12 (this settings can be checked by pressing the button "MENU" at the PRCU 12).
• Click the "OK" button. • Enter the password of the unit and click the "OK" button.
• Enter the Ethernet password and click the "OK" button.
—> The default setting of the Ethernet password is "Grundig" and should be changed after the first configuration.
—> The window "Connection will be activated" appears, the settings will be transmitted and after that the PRCU 12 will be rebooted. Now the basic unit is accessible via Ethernet.
• Click the "OK" button.
- 17 -
PRCU 12
6.2
Connection establishment at configured basic unit
By clicking the button or selecting the menu "Plat" / "Activate connection" the window "Connection settings" appears.
—> In the menu "Connection settings" in area "Choice" you can select bet ween: – "Com" for a "direct" connection with a PC (via RS-232 connector), – "Modem" for remote maintenance via modem and – "Ethernet" for remote maintenance via Ethernet. —> "Ethernet" is selected in the current example.
• Enter the IP address and separated by a colon the port. —> IP address 212.10.175.80 and port 60003 is used in this example. • Click the "OK" button.
The status indicator left below will change from to when the password is entered and the "OK" button is clicked. The PSW 1000 is connected to the basic unit.
- 18 -
PRCU 12
6.3
Alarm messages via SNMP traps
Alarm messages can be sent via SNMP (Simple Network Management Protocol).
• Activate the submenu "Plant setting" by clicking the the menu "Edit"/"Plant setting".
—> A PSCU 6000 for monitoring must be present in your plant and the check box "PSCU 6000 available" must be activated.
• Activate the submenu "Alarm SNMP-Traps".
—> Three IP addresses can be entered and activated by hooks.
- 19 -
button or selecting
PRCU 12
In case of an alarm message it will be sent to the activated IP addresses as a SNMP trap.
Below see an example of the structure of an alarm message:
Seq { Int =1; SNMP Version Str =public; Community String Inform { Int =6; RequestId Int =1; Error Int =0; ErrorIndex Seq { Seq { OID =1.3.6.1.4.1.29343.1.0.0.1 Str =Alarm report: 1 Channel in Nuremberg (Tel.: 212.20.172.90:60003) been cancelled } } } }
- 20 -
PRCU 12
7
Software update via the BE-Flash software
—> The PRCU 12 management system must already be configured for remote maintenance via Ethernet.
• Insert the enclosed CD in the appropriate drive of the PC / laptop.
• Start the “BEflash.exe” programme which is located in the directory BEflash of the CD by a double click.
• Set field "Serial Port:" in area "Configuration" to "Ethernet". • Select in field "Device:" in area "Configuration" the type of cassette which shall be updated. • Open menu "File"/"Open …" and select the corresponding data file.
- 21 -
PRCU 12
• After pressing the button or selecting the menu "Action" / "Program" the window "Select IP-Address" appears.
• Enter the IP address and the port separated by a colon. —> In the example the IP address 127.0.0.1 and port 60000 is used. —> IP address and port must be set to the same value as selected during the configuration of the PRCU 12, respectively the public IP address of the router and the port which must be forwarded to the PRCU 12.
• Enter the password and click the "OK" button.
—> The submenu "Select Box" shows the current software version of the cassette and the slot in which the cassette is fitted. In this menu the cassette to be updated can be selected. • Start the programming by clicking the "OK" button.
—> "Programming OK" is shown in a green status line when the programming is finished successfully.
At the following cassettes the programming starts not until the transmission is finished: PHDQ x003 TPS PSDQ x003 TPS PHDQ x002 BC PSDQ x002 BC PSDQ x004 MX PSDP PTDP x200 PSDF 2000
Round about 15 min. are needed for transmission and programming of one cassette. —> In case of an error, the error text is shown in a red status line.
- 22 -
PRCU 12
- 23 -
PRCU 12
Alterations reserved. Technical data E. & O.E.
© by GSS GmbH