Preview only show first 10 pages with watermark. For full document please download

Remote Controlling - Apw

   EMBED


Share

Transcript

REMOTE CONTROLLING Intelligent PDU, display, switch, KVM and electronic lock www.apw.eu.com 2 REMOTE CONTROLLING PDU PXE - IPDU The PXE family of intelligent power distribution units (iPDUs) offers real-time remote monitoring of power at the rack PDU inlet, or metering at the circuit-level. Integration with environmental sensors provides monitoring of rack temperature, humidity, floor pressure, and airflow. PXE is a great way to start monitoring to make informed capacity planning decisions, improve rack power availability, and save money through energy efficiency initiatives. PXE-1190R PXE-1392 PXE-1488 PXE-1493 PXE-1847 Single phase, 230-240V, 16A, 8 outlets: IEC C-13, plug: IEC 60309 16A, 3.7 – 3.8 kVA, 1U horizontal PDU, Ethernet, RS-485 serial, USB-B, and environment sensor ports. Single phase, 230-240V, 32A, 16 outlets: 16 x IEC C-13, plug: IEC 60309 32A, 7.4-7.7 kVA, 0U vertical PDU, Ethernet, RS-485 serial, USB-B, and environment sensor ports. Single phase, 230-240V, 16A, 24 outlets: 20 x IEC C-13 and 4 x IEC C-19, plug: IEC 60309 16A, 3.7 – 3.8 kVA, 0U vertical PDU, Ethernet, RS-485 serial, USB-B, and environment sensor ports. Single phase, 230-240V, 32A, 24 outlets: 20 x IEC C-13 and 4 x IEC C-19, plug: IEC 60309 32A, 7.4 – 7.7kVA, 0U vertical PDU, Ethernet, RS-485 serial, USB-B, and environment sensor ports, 2 x 16A circuit breakers. Single phase, 230-240V, 32A, 42 outlets: 36 x IEC C-13 and 6 x IEC C-19, plug: IEC 60309 32A, 7.4 – 7.7 kVA, 0U vertical PDU, Ethernet, RS-485 serial, USB-B, and environment sensor ports, 2 x 16A circuit breakers. Note: Three-phase voltage models are also available PX2000 - IPDU The PX-2000 family of high-quality, intelligent rack power distribution units (iPDUs) offers real-time remote unit-level power monitoring of current (amps), voltage, power (kVA, kW), power factor and energy consumption (kWh) with ISO/IEC +/- 1% billing-grade accuracy. The PX-2000 also supports plug-and-play environmental sensors. Users can define thresholds and receive alerts when thresholds are crossed for both power and environmental events. PX2-2486 1PH, 230V AC, 16A, 24 outlets: IEC C-13, plug: IEC60309 16A, 3.7kVA, Zero U vertical PDU, Ethernet, serial, USB-A, USB-B and sensor connections. PX2-2493 1PH, 230V AC, 32A, 24 outlets: 20 x IEC C-13, 4 x IEC C-19, plug: IEC60309 32A, 7.4kVA, Zero U vertical PDU, Ethernet, serial, USB-A, USB-B and sensor connections. PX2-2139R PX2-2190R PX2-2260 PX2-2297 PX2-2500 1PH, 230V AC, 16A, 8 outlets: BS1363, plug: IEC60309 16A, 3.7kVA, 2U horizontal PDU, Ethernet, serial, USB-A, USB-B and sensor connections. 1PH, 230V AC, 16A, 8 outlets: IEC C-13, plug: IEC60309 16A, 3.7kVA, 1U horizontal PDU, Ethernet, serial, USB-A, USB-B and sensor connections. 1PH, 230V AC, 16A, 12 outlets: IEC C-13, plug: IEC60309 16A, 3.7kVA, Zero U vertical PDU, Ethernet, serial, USB-A, USB-B and sensor connections. 1PH, 230V AC, 32A, 12 outlets: IEC C-13 x 8, IEC-C19 x 4, plug: IEC60309 32A, 7.4kVA, Zero U vertical PDU, Ethernet, serial, USB-A, USB-B and sensor connections. 1PH, 230V AC, 32A, 24 outlets: IEC C-13, plug: IEC60309 32A, 7.4kVA, Zero U vertical PDU, Ethernet, serial, USB-A, USB-B and sensor connections. Note: Three-phase voltage models are also available www.apw.eu.com REMOTE CONTROLLING PDU and smart rack controller PX5000 - IPDU The PX-5000 series of high-quality rack power distribution units (PDUs) offers real-time remote unit-level and individual outlet-level switching and power monitoring of current (amps), voltage, power (kVA, kW), power factor and energy consumption (kWh) with ISO/ IEC +/- 1% billing-grade accuracy. The PX-5000 also supports plug-and-play environmental sensors. Users can define thresholds and receive alerts when thresholds are crossed for both power and environmental events. The PX-5000 series is available in Zero U (vertical mount) and 1U and 2U (horizontal mount) form factors with a wide variety of NEMA, IEC and other plugs and receptacles, including models that support high power distribution such as 400V. Precise power information can be monitored, and the PX-5000 configured, via a user-friendly Web browser GUI or command line interface. Power information is also displayed at the PDU locally. Security is ensured with up to 256-bit encryption, strong passwords and advanced authorization options, including permissions, LDAP/S and Active Directory®. Plus the PX-5000 series is fully compatible with Power IQ energy management software solutions. PX3-5190R PX3-5440R PX3-5466R PX3-5260V PX3-5440V PX3-5466V PX2-5493X Single phase, 230V AC, 16A, 8 outlets: 8 x IEC-C-13: IEC60309 16A, 3.8kVA, 1U horizontal PDU, Ethernet, serial, 2 x USB-A, USB-B and sensor connections. Single phase, 230V AC, 16A, 20 outlets: IEC C-13, plug: IEC60309 16A, 3.8kVA, 1U horizontal PDU, Ethernet, serial, 2 x USB-A, USB-B and sensor connections. Single phase, 230V AC, 32A, 20 outlets: IEC C-13, plug: IEC60309 32A, 7.36kVA, 2U horizontal PDU, Ethernet, serial and 2 x USB-A, USB-B and sensor connections. Single phase, 230V AC, 16A, 12 outlets: 12 x IEC-C-13: IEC60309 16A, 3.8kVA, Zero U Vertical PDU, Ethernet, serial, 2 x USB-A, USB-B and sensor connections. Single phase, 230V AC, 16A, 20 outlets: IEC C-13, plug: IEC60309 16A, 3.8kVA, Zero U vertical PDU, Ethernet, serial, 2 x USB-A, USB-B and sensor connections. Single phase, 230V AC, 32A, 20 outlets: IEC C-13, plug: IEC60309 32A, 7.36kVA, Zero U vertical PDU, Ethernet, serial and 2 x USB-A, USB-B and sensor connections. Single phase, 230V AC, 32A, 24 outlets: 20 x IEC C-13, 4 x IEC C-19, plug: AC Terminal, 7.36kVA, Zero U vertical PDU, Ethernet, serial, USB-A, USB-B and sensor connections. Note: Three-phase voltage models are also available EMX – Smart rack controller The EMX smart rack controller device is a central connection point for all of environmental sensors. The EMX smart rack controller offers up to eight sensor ports, eight feature ports for dynamic asset-tracking solution and eight RS-485 ports, all in a 1U form factor. Smart rack monitoring solution helps data center and facilities managers: • Minimize the hours needed to track IT assets. • Ensure uptime by monitoring racks for possible hot spots. • Save on cooling costs by confidently raising data center temperatures. • Maintain cabinet security w/ USB webcams and contact closure sensors. • Improve data center uptime by receiving environment alerts. • Make strategic decisions on environmental design and modification EMX2-111 Smart rack controller with 1 x RJ-12 sensor port, 1 x RJ-45 feature port for AMS, 1 x RJ-45 RS-485 port, 1 x USB-A port, 1 x USB-B port, 1 x RJ-45 Ethernet port, 1 x DB-9M console/ modem, LCD display. EMX2-888 Smart rack controller with 8 x RJ-12 sensor ports, 8 x RJ-45 feature ports for AMS, 8 x RJ-45 RS-485 ports, 2 x USB-A ports, 1 x USB-B port, 1 x RJ-45 Ethernet port, 1 x DB-9M console/ modem, 2 x contact closure, LCD display. 3 4 REMOTE CONTROLLING Environment sensors Environment sensors Environment sensors are deployed as plug-and-play options for PX intelligent rack PDUs, EMX rack controllers, PX inline meters and branch circuit monitors eliminating the need for a separate controller. Environment data is instantly sent to DCIM software. A simple web-based interface allows data center managers to see real-time environment data and report trends over time. Environment sensors enable data center managers to: • Ensure uptime by monitoring racks for potential hot spots. • Save on cooling by confidently raising data center temperatures. • Maintain cabinet security with contact closure sensors. • Improve data center availability by receiving environment alerts. • Make strategic decisions on cooling design and containment. • Set thresholds and alerts to monitor onsite or remote facilities. DPX-T1 Single temperature sensor - 10ft (3m) cable length - RJ-12 connector. DPX-T1H1 Single combo temperature and humidity sensors - 10ft (3m) cable length - RJ-12 connector. DPX-T1DP1 Dual combo temperature and humidity sensors - 10ft (3m) cable length and additional 10ft (3m) between combination sensors- RJ-12 connector. Combo of three temperature and one humidity sensors (T, T+H and T) - 10ft (3m) cable length and additional 10ft (3m) between combination sensors- RJ-12 connector. Differential air pressure with temperature sensor. DPX-AF1 Single airflow sensor. DPX-ENVHUB4 4-port hub for Raritan DPX environmental sensors only; comes with mounting bracket and RJ12-to-RJ12 cable to connect to, and receive power from PX. DPX-CC2-TR Dual contact closure sensor - requires customer-provided Normally Closed (NC) or Normally Open (NO) switch like door open/close, door locked/unlocked, smoke (present or absent). Factory default is NC. Each of the two ports (channels) can be independently set to NC or NO. RJ-12 connection to the PX/PX2 PDU. Note: No support for water sensor. Requires firmware PX1.4.1 or PX2.1.5. DPX-WSF-KIT DPX-WSC-35-KIT DPX-WSC-70-KIT Floor water sensor plus contact closure sensor. 3.5M rope water sensor plus contact closure sensor. 7M rope water sensor plus contact closure sensor. DPX-T2H2 DPX-T3H1 Fire Protection Unit (FPU) Description Order code Unit Master FPU w/ smoke detector and GAS FM200 for 1,5m VA295-000000 Unit Slave FPU w/ smoke detector and GAS FM200 for 1,5m VA295-000001 3 3 www.apw.eu.com REMOTE CONTROLLING Fail-Safe Transfer Switch Fail Safe Transfer Switch The Fail-Safe Transfer Switch (FSTS) features two input power feeds, from separate AC circuits, to supply single-power supply equipment with dual, redundant power sources. A primary AC circuit provides power to the connected device(s). If that primary power sources becomes unavailable for whatever reason, then the FSTS auto-switches to the secondary power source to support the connected equipment. The transfer from one power source to the other is seamless to the connected equipment. When the secondary power source is available, an interruption of the primary power source will not affect the equipment’s uptime or performance. Unique to the FSTS is the ability to designate which power source is primary and which is secondary. With the Primary Select switch, a power engineer simply toggles the switch from primary to secondary, which transfers the load from one power feed to the other. Now, the “secondary” becomes “primary” and the power engineer can safely work on the first power source without dropping power to the connected equipment. Also exclusive to the FSTS is the ability to select the high voltage (208-230V) or low voltage (110-120V) operating range of the AC power source. Use the FSTS as a universal power transfer switch for all cabinets and servers, regardless of the voltage. Before applying power for the first time, just remove a panel and then choose the appropriate voltage range. Order code PTTS-H008-0-02M Fail-Safe Transfer Switch, 2 -20A power input feeds, 8 - C13 power outlet receptacles, Fail-safe redundancy between primary and secondary, Primary-Select switch to designate primary power source, Range-Select switch to designate operating range (voltage). VA390-787182 Key Features: • • • • • • • • • • • • Dimension: 1U 19”H x W x D: 44 x 437 x 178 mm 19” rack-mount brackets included. 8 IEC 60320/C13 outlets Sum of all 8 outlets must be less than or equal to 16A Each outlet rated by UL/CSA to 12A for 100-120V and 208-240V operation, and by TUV to 10A for 230V operation. Dual-brace cable retainer brackets on power input feeds Clip-style cable-retention retainer brackets at each power outlet Adjustable mounting for the front or rear flush panel 2 IEC 60329/C20 Inlets Primary Power Source Input Secondary Power Source Input Requires both power input feeds to be phase-synchronize International norms and approvals: • US & Canada (cTUVus mark) to UL 60950-1:2003 and CAN/CSA 22.2 No. 60950-1-03 • European Union (TUVGS mark) to EN 60950-1:2001, FCC Class A Part 15; CE; EMC - EN 55022 Class A, EN 55024 Order code Patch Cord Options: PTCORD-1 IEC 60320 / C19 NEMA L6-20P (20A Twist Lock) 10ft (3m) PTCORD-L2 IEC 60320/C19 - CEE 7/7 Schuko 10ft (3m) PTCORD-3 IEC 60320 / C19 IEC 60309 (BS4343, CEE17) 16 / 20A Blu (UK Commando) 10ft (3m) on request VA390-787636 on request PTCORD-4 IEC 60320 / C19 BS1363 13A (UK) 10ft (3m) on request PTCORD-5 IEC 60320 / C19 5-15P (15A Straight-Blade) 10ft (3m) on request PTCORD-6 IEC 60320 / C19 5-20P (20A Straight-Blade) 10ft (3m) on request PTCORD-7 IEC 60320 / C19 5-20P (20A Straight-Blade) 10ft (3m) on request - IEC 60320 C-13/C-14 (1,8m) VA386-200705 5 6 REMOTE CONTROLLING KVM Switch MATRIX KVM Simultaneous Multi user KVM switch MU Series MU-IP Series M Series M-IP Series 1U Cat6 KVM switch to connect 16 - 32 server up to 40 meters. Remote console up to 300 mt 1U Cat6 KVM switch to connect 16 - 32 server up to 40 meters. Remote console via IP 1U DB15 KVM to connect 16 - 32 server up to 40 meters. Remote console up to 300 mt 1U DB15 KVM switch to connect 16 - 32 server up to 40 meters. Remote console via IP Matrix Cat6 KVM COMBO Cat6 KVM Combo Cat6 KVM switch U Series - XX01 U Series - XX02 U-IP Series 1U KVM switch to connect 8, 16, 32 servers up to 40 meters 1U KVM switch to connect 8, 16, 32 servers up to 40 meters - local console up to 300 meters 1U KVM switch to connect 8, 16, 32 servers up to 40 meters - remote console via IP COMBO Cat6 KVM COMBO DB15 KVM Combo DB-15 KVM switch CV-S Series CV-X Series IP Series 1U DB-15 KVM to connect 8, 16, 32 servers up to 40 meters - DB-15 connection 1U DB-15 KVM switch to connect 8, 16, 32 servers up to 40 meters - local console up to 300 meters 1U DB-15 KVM switch to connect 8, 16, 32 servers up to 40 meters - remote console via IP COMBO DB-15 KVM KVM Extender CV-S101 Series IP-101 Series Combo KVM extender - remote console up to 300 meters Combo KVM extender - remote console via IP COMBO KVM Extender Keyboard drawer RK-1 1U keyboard drawer w/ 8 - 16 - 32 KVM ports RK-2 1U keyboard drawer 440 mm depth RK-2GOB230USB 1U keyboard drawer 237 mm depth RK-2GOB230USB www.apw.eu.com REMOTE CONTROLLING Rackmount display and KVM LCD drawer LCD Display - Widescreen Drawers versions RP-W119 1U drawer w/ 19” widescreen LCD display * QUAD version available LCD Display - Widescreen Rackmount versions RP-F821 RP-W719 RP-F617 8U rackmount - 21” widescreen LCD display 7U rackmount - 19” widescreen LCD display 6U rackmount - 17” widescreen LCD display RP-W719 * QUAD version available 4:3 LCD display Drawers versions RP-120 RP-119 RP-117 1U drawer with 20” LCD display 1U drawer with 19” LCD display 1U drawer with 17” LCD display RP-120 4:3 LCD display Rackmount versions RP-920 RP-819 RP-717 9U rackmount - LCD Display 20” 8U rackmount - LCD Display 19” 7U rackmount - LCD Display 17” LCD keyboard drawer w/ optional KVM switch 1U keyboard drawer L120 1U drawer w/ 20” display, 1600 x 1200 - 16 - 32 ports integrated KVM D119 1U keyboard drawer with 19” widescreen display option for 16 - 32 KVM D117 1U keyboard drawer with 17” widescreen display option for 16 - 32 KVM L120 2U keyboard drawer RKP-2419 RKP-2417 2U keyboard drawer with 19” display - optional 8 - 16 - 32 KVM ports - 480 mm depth 2U keyboard drawer with 17” display - optional 8 - 16 - 32 KVM ports - 480 mm depth RKP-2417 7 8 REMOTE CONTROLLING Electronic lock As information technology takes on increased importance the protection of data and asset becomes even more critical. The access management solutions available offer a local or remote control for a single cabinet or a full datacenter. Local control: the cabinet is equipped with a special handle with integrated keypad or smart card or biometric reader. The stand alone version is suitable for small stand-alone solutions, which do not require network ability. This system is easy to install and 19” Module Module Operating Module S E N S OR S Numeric Keypad Access Badge Access Biometric Access maintain and can be managed by an user with “master code number” Remote control: a modular and scalable system to centralize the management of datacenters in remote locations across the network. A simple graphic user interface that centralize the access management. A friendly user interface reports the status of each cabinet and shows any alarm. The SNMP interface can be easily integrated with the existing network infrastructure. Box Module Kit Module Module Operating Module R E L A Y S GOMA ELETTRONICA SpA 10146 Torino - Italy Via Carlo Capelli, 89 Tel: +39 011 7725024 Fax: +39 011 712298 www.gomaelettronica.it All trademarks are the property of their respective owners GOMA ELETTRONICA SpA • MKA-CTG-EN 0517