Data Sheet Resistance Thermometer MM 1600 Mineral insulated FRODE PEDERSEN Application Type Mineral insulated resistance thermometer are used for measuring temperature where MM 1 a flexible, rugged, corrosive resistant, and fast sensor is needed Operating range is in solid, fluid and gaseous medias up to 600°C Fields of application - Containers, pipelines, chemical apparatus - Process industry - f.inst. petrochemical and small furnaces - Machinery, in laboratories and experimental plants MM 3 MM 4 MM 5 Cable length MM 2 Technical features Pt100 resistance thermometer acc. to IEC 751 3-wire connection is standard A mineral resistance thermometer with 2, 3, 6 or 8 wires are housed in a thinwalled metal tube. The wires are insulated in firmly compacted ceramic powder. The resistance element (single or duplex) is connected to the inner wires, embedded in ceramic powder and closed with a steel cap Connected to the process by brazing, adjustable fittings or other mechanical brackets Nominal length Ordering The requested sensor is selected from the table below The colour code means: Standard: Built of standard modules (short delivery time) Variant: Modified standard modules Speciel: Special versions and material. We are specialist intemperature measurement. Please contact us and we will do our best to solve your specific measuring task Ordering information Specification number Sensor 1600- Type Cable length (meter) MM 1 With (Lemo) connector 1) 0 0 0 None (for type MM 1, MM 2, MM 3) MM 2 100 mm flying leads. PVC insulated 1 0 1 1 meter (for type MM 4, MM 5) MM 3 As MM 2, only 6mm OD 2 x x.x Special (Min 0.1 meter) MM 4 With cable 3 MM 5 With cable and connector (Lemo) 1) 4 Special: s Cable type 0 None (for type MM 1, MM 2, MM 3) Note 1: Female connector is ordered separately item no. 60D714 1 0.25mm 2. PVC insulated and inner braided screen 2 0.25mm 2. Silicone insulated Sheath diameter 3 0.382mm 2. Teflon (FEP) insulated, inner braided screen 0 4 0.5mm 2. Fibreglass insulated+steel braid 4.5mm 1 s Special: 6mm 2 Special: s 3mm Connection. Wiring configuration Sheath material Stainless, acid proof steel, W. no. 1.4571 (AISI 316Ti) 0 Special: s 0 3-wire (only 1xPt100) 1 4-wire (only 1xPt100) 2 2-wire (always for 2xPt100) Tolerance acc. to IEC 751 Nominal length (mm) 2) 150 0 300 0 500 0 0 0 0 1 3 5 5 0 0 0 0 0 1 0 0 0 Interim lengths ( Min. 100, max. 30.000) x x x x x Class B, i.e. ± (0.3°C + 0.005 x t actual )°C 1 Class A, i.e. ± (0.15°C + 0.002 x t actual )°C 2 1/3 Class B @ 0°C, i.e. ± (0.10°C + 0.005 x t actual )°C 3 0 1000 0 5 s 1/6 Class B @ 0°C, i.e. ± (0.05°C + 0.005 x t actual )°C Special, i.e. ± (0.05°C + 0.0013x t actual )°C) Special: Note 2: Length >800mm is delivered coiled Resistance value (ohm) acc. to IEC 751 Measuring range -50 +600°C (Only tolerance 0 og 1) 0 -50 +400°C (Only tolerance 2, 3, 4 or 5) 1 Special: s 0 1xPt100 1 2xPt100 2 1xPt1000 s Special Accesesories Customer information Process connection: See data sheet 9113 Name: Tel: TECHNICAL DATA All dimensions in mm Note 1: 36mm for 6mm OD sheath 60 (Not bendable) 43 1) 25-50 Temperature sensitive length Crimped 6 OD Crimped Crimped 6 OD Cable length MM 5 Cable length 100 36 25 7 OD Crimped 6 OD MM 4 Nominal length Type MM 3 MM 2 100 MM 1 43 1) Dimensions D Properties for cable Insulation PVC Silicone Teflon (FEP) GLGLO, Fibreglass+steel braid Temperature range - 5 + 70°C -50 +180°C -50 +200°C -20 +400°C Application General use Flexible, heat resistance Corrosion and heat resistance High temperature, not water tight Properties for mineral insualated cable Used in W.no. 1.4571 max. 800°C Recommended Recommended Suitable Suitable Recommended Not recommended Not recommended Liquids Acid Sulphur atmospheres Clorine atmospheres Oxidizing atmospheres Reducing atmospheres Carburizing atmospheres Bending radius Min. bending is 5 x D @ repeatable bendings 2 x D @ stationary bending Insulation resistance Depending of temperature, length and diameter Note: Diameter U Rmin The insulation resistance is dependent upon the length of the cable. mm Voltage M ohm x m Therfore, it is listed as a length related resistance in Mohm x m for length > 1 meter 100 3-6 100 and Mohm for length <1 meter Thermoelectric influence Thermoelectric voltage -< 10 µV @ 200°C Note: Response time Sheath diameter 3.0 4.5 6.0 Response time in seconds (guidelines) In water @ 0.4m/sec. In air @ 2m/sec. t 0.5 t 0.9 t 0.5 t 0.9 2 7 36 94 4 12 42 126 7 20 48 151 The 0.5/0.9 time is the time that it takes the sensor to reach 50%/90% of the final value of a temperature change of a medium. If media and velocity are different from the ones stated, the time can change significantly. Connection diagram - connector 1xPt100 3-wire 2-wire 4-wire 2xPt100 2-wire Connection diagram - cable White Brown White Brown AMETEK DENMARK A/S Teflon w/screen Screen connected to outer sheath 1xPt100 2xPt100 2- 3- 4-wire 2-wire Red Red Red/green Red/green White/green White Silicone 1xPt100 2- 3- 4-wire Blue Yellow White/green White GYDEVANG 32-34, DK - 3450 ALLERØD Red White GLGLO 2xPt100 2-wire Blue Yellow Red White TEL: +45 48168000 1xPt100 2- 3- 4-wire White White 2xPt100 2-wire White White White White FAX: +45 48168080 White White SS-FP-MM-1600-UK. Version 201109 PVC w/screen Screen connected to outer sheath 1xPt100 2xPt100 2- 3- 4-wire 2-wire Green Green Yellow Yellow