Transcript
NVLAP Lab Code 500089-0
Report Number:
RESTL-2014-0017
Model:
BXSPWA02FG-US
Date:
01/15/2014
Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Bernard Krauska Cree, Inc. 9201 Washington Avenue Racine, WI 53405
Prepared By:
Linjie Li, Photometric Technician
Approved By:
Steven Bowers, Photometric Test Engineer
Cree, Inc | 9201 Washington Avenue | Racine, WI 53406 Test Report Number: RESTL-2014-0017 This report contains data that are not covered by the NVLAP accreditation.
Page 1 of 12 RESTL-R010 Rev D
NVLAP Lab Code 500089-0 Product Information Manufacturer Model Number (SKU) Serial Number LED Type
Cree, Inc. BXSPWA02FG-US PL02962-001 MDA
Product Description Cast gray painted metal housing. One circuit board with four LEDs and white plastic trim plate. One clear plastic non-integral optic below each LED. Driver Information (Where Applicable) Integral Length
Width
Height
9.0”
12.0”
4.0”
Sample The following sample was submitted for evaluation
Cree, Inc | 9201 Washington Avenue | Racine, WI 53406 Test Report Number: RESTL-2014-0017
Page 2 of 12 RESTL-R010 Rev D
NVLAP Lab Code 500089-0 Key Photometric Data
Sphere Output
Goniophotometer
2766
2738.8
lm
113.13
112.15
lm/W
Luminous Flux Efficacy Correlated Color Temperature (CCT)
K
3839
Color Rendering Index (CRI)
72
R9
-20
Duv
0.005
S/P Ratio*
1.44
Sphere
Goniophotometer
Electrical Measurements
120V
277V
120V
277V
Input Wattage
24.45
24.47
24.42
24.46
W
Input Current
0.20
0.098
0.21
0.10
A
Input Voltage
120.13
277.14
119.96
277.11
V
Power Factor
0.991
0.901
0.991
0.903
0
0
0
0
W
Total Harmonic Distortion (Voltage)
0.11
0.14
0.10
0.09
%
Total Harmonic Distortion (Amperage)
6.43
15.25
6.54
14.37
%
Off-State Power
Note: All photometric measurements taken at 120VAC.
Luminous Intensity Distribution Max Candela
Goniophotometer 2302.4
Cd
Angle of Max Candela (Horizontal)
60
˚
Angle of Max Candela (Vertical)
60
˚
Key Test Parameters
Sphere Output
Goniophotometer
Stabilization Time
43
43
min
Total Operating Time (Stabilization + Test)
47
63
min
24.1
24.0
˚C
Ambient Temperature
Cree, Inc | 9201 Washington Avenue | Racine, WI 53406 Test Report Number: RESTL-2014-0017
Page 3 of 12 RESTL-R010 Rev D
NVLAP Lab Code 500089-0 500089 Chromaticity Coordinates ** x
y
u
v
u’
v’
Duv
0.3918
0.3946
0.2254
0.3406
0.2254
0.5109
0.005
Color Rendering Index Details ** Ra
R1
R2
R3
R4
R5
R6
R7
R8
R9
R10
R11 11
R12
R13
R14
72
70
77
83
73
69
67
82
56
-20
45
69
40
70
90
Chromaticity Diagram **
Cree, Inc | 9201 Washington Avenue | Racine, WI 53406 Test Report Number: RESTL-2014-0017
Page 4 of 12 RESTL-R010 Rev D
NVLAP Lab Code 500089-0 500089 Spectral Distribution ** λ(nm) 360 370 380 390 400 410 420 430 440 450 460 470 480 490 500 510 520
W/nm 0.000175 0.000099 0.000102 0.000035 0.000043 0.000738 0.004596 0.015384 0.037063 0.041866 0.016044 0.007378 0.004795 0.005909 0.012290 0.022214 0.031328
λ(nm) 530 540 550 560 570 580 590 600 610 620 630 640 650 660 670 680 690
Dominant Wavelength ** Peak Wavelength **
W/nm 0.037114 0.040292 0.042383 0.044405 0.046178 0.047367 0.047517 0.046057 0.043081 0.038672 0.033638 0.028203 0.023007 0.018393 0.014246 0.010952 0.008298
λ(nm) 700 710 720 730 740 750 760 770 780 790 800 810 820 830
577 446
W/nm 0.006224 0.004669 0.003507 0.002593 0.001919 0.001409 0.001065 0.000795 0.000578 0.000412 0.000297 0.000223 0.000161 0.000118
nm nm
Spectral pectral Power Distribution (W/nm) **
Cree, Inc | 9201 Washington Avenue | Racine, WI 53406 Test Report Number: RESTL-2014-0017
Page 5 of 12 RESTL-R010 Rev D
NVLAP Lab Code 500089-0 Zonal Lumen Summary Zone 0-5 5-10 10-15 15-20 20-25 25-30 30-35 35-40 40-45 45-50 50-55 55-60 60-65 65-70 70-75 75-80 80-85 85-90
Lumens 11.6 37.7 68.3 102.4 135.4 162.6 183.7 196.1 228.8 304.7 353.4 315.0 268.5 185.8 112.6 50.2 18.0 3.8
% of Total 0.4% 1.4% 2.5% 3.7% 4.9% 5.9% 6.7% 7.2% 8.4% 11.1% 12.9% 11.5% 9.8% 6.8% 4.1% 1.8% 0.7% 0.1%
Zone 90-95 95-100 100-105 105-110 110-115 115-120 120-125 125-130 130-135 135-140 140-145 145-150 150-155 155-160 160-165 165-170 170-175 175-180 Total
Lumens 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2738.8 lm
Cree, Inc | 9201 Washington Avenue | Racine, WI 53406 Test Report Number: RESTL-2014-0017
% of Total 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 0% 100%
Page 6 of 12 RESTL-R010 Rev D
NVLAP Lab Code 500089-0 500089 Candela Plot
Roadway Utilization
Illuminance Plot
Roadway Summary
Lumens
Cutoff Classification Distribution Downward Street Side Downward House Side Downward Total Upward Street Side Upward House Side Upward Total Total Lumens
Full Cutoff Type II, Short 2,083.2 76.1% 655.7 23.9% 2,738.9 100% 0 0% 0 0% 0 0% 2,738.9 100%
Cree, Inc | 9201 Washington Avenue | Racine, WI 53406 Test Report Number: RESTL-2014-0017
% Lamp
Page 7 of 12 RESTL-R010 Rev D
NVLAP Lab Code 500089-0 Luminaire Classification System
Cree, Inc | 9201 Washington Avenue | Racine, WI 53406 Test Report Number: RESTL-2014-0017
Page 8 of 12 RESTL-R010 Rev D
NVLAP Lab Code 500089-0 Candela Tabulations 0
5
15
25
35
45
55
60 62.5
65 67.5
70 72.5
75 77.5
80 82.5 85 87.5
90
95
105 115 125 135 145 155 165 175 180
0 461 461 461 461 461 461 461 461 461 461 461 461 461 461 461 461 461 461 461 461 461 461 461 461 461 461 461 461 461 461 2.5 534 536 535 530 524 514 501 494 492 490 487 485 482 480 477 474 472 469 466 463 460 452 443 438 435 434 432 429 428 427 5 606 607 606 602 594 580 560 548 543 538 532 526 521 515 509 503 496 490 483 477 468 452 437 429 425 423 420 417 415 415 7.5 662 664 663 660 651 638 616 601 596 590 582 575 567 558 549 540 529 519 509 500 484 457 435 425 419 416 412 409 406 406 10 710 714 712 710 704 694 671 654 646 639 630 622 612 603 591 580 566 552 539 526 503 463 434 422 414 412 410 406 405 405 12.5 742 744 746 754 757 750 733 713 703 694 681 669 656 643 629 616 601 585 569 552 522 470 436 423 418 417 417 415 414 415 15 770 771 774 785 794 800 799 783 771 759 741 723 704 686 668 651 632 614 595 576 539 481 446 430 422 423 423 420 418 419 17.5 796 799 807 817 829 847 854 847 838 829 806 784 758 733 708 683 659 636 615 594 555 498 461 433 420 421 420 415 413 413 20 832 835 844 859 864 878 890 883 874 865 842 820 789 758 728 698 671 645 625 604 570 523 480 435 411 408 412 407 404 404 22.5 868 875 895 906 897 894 888 879 868 856 832 809 776 744 713 683 662 642 627 613 588 552 485 433 402 392 400 400 398 398 25 900 910 952 929 909 892 866 852 842 833 810 787 756 725 697 669 654 640 633 626 614 571 483 428 392 376 387 393 392 393 27.5 921 933 965 927 899 878 840 824 816 809 788 767 739 712 686 660 653 646 645 644 632 575 474 422 383 364 370 380 378 378 30 938 944 951 905 886 867 831 807 800 793 775 756 731 706 681 657 655 652 649 646 629 567 465 416 377 359 358 370 363 363 32.5 956 962 949 883 874 848 829 798 788 779 764 748 728 707 678 648 642 636 634 633 616 553 460 410 380 368 350 349 336 333 35 956 963 934 873 869 830 818 789 779 768 755 742 723 704 670 635 623 612 613 614 601 545 455 410 397 338 286 276 266 264 37.5 924 935 909 864 870 821 792 781 767 754 745 737 720 703 663 622 604 585 590 596 587 541 454 424 350 262 228 221 218 216 40 1002 992 918 852 870 828 769 768 758 748 740 732 719 706 678 651 635 619 635 651 646 530 450 387 265 219 194 183 178 176 42.5 1279 1279 1181 1040 882 858 792 778 769 760 760 760 774 788 781 774 740 706 711 716 699 507 422 301 223 187 163 148 141 139 45 1320 1336 1330 1229 1134 900 848 803 821 838 880 922 946 969 944 919 862 805 782 760 702 474 365 242 192 158 134 118 109 106 47.5 1302 1331 1365 1418 1303 1226 1256 1241 1235 1228 1228 1228 1198 1167 1119 1071 997 922 864 806 660 430 300 210 165 131 108 50 1040 1113 1292 1519 1692 1685 1939 1986 1909 1832 1728 1624 1498 1371 1293 1215 1120 1025 924 822 606 390 248 179 139 106
95
87
85
89
80
73
72
52.5 584 639 848 1260 1780 1982 2112 2144 2146 2147 1981 1814 1674 1533 1411 1290 1171 1052 938 823 584 360 217 151 115
89
77
72
65
64
55 233 248 376 638 1136 1882 2213 2054 2065 2077 1918 1759 1642 1526 1443 1360 1255 1150 1024 898 657 396 234 149 104
81
71
64
60
60
57.5 180 185 214 424 753 1512 2196 2182 2113 2044 1926 1809 1721 1633 1567 1501 1398 1295 1174 1052 809 424 247 152 103
82
69
61
59
60
60 144 148 168 236 591 1106 2149 2302 2204 2106 1938 1770 1699 1627 1565 1504 1389 1274 1138 1001 903 447 230 130
91
79
68
62
60
64
62.5 118 121 131 176 376 820 1914 2190 2129 2069 1876 1684 1599 1513 1437 1361 1242 1122 997 873 789 367 160 102
84
81
75
66
61
63
98
97
86
65 81
84
101 133 202 530 1509 1930 1899 1868 1634 1401 1335 1270 1225 1180 1090 1000 874 749 612 231 120
88
88
73
74
67.5 52
54
67
91
109 129 132 118 100
98
97
142 292 1112 1464 1461 1458 1281 1104 1096 1087 1060 1033 947 860 727 593 436 160
96
70 44
43
45
63
96
138 770 1079 1098 1116 1004 891 890 889 861 832 756 680 566 451 324 120
81
105 139 158 148 122 102
98
72.5 49
47
41
44
66
100 487 798 805 813 746 679 678 677 659 642 592 542 451 360 239
81
77
125 151 135
96
68
59
57
75 40
39
37
37
46
78
266 529 523 517 490 463 462 460 433 406 372 338 300 263 165
59
82
136 104
60
43
34
30
29
77.5 29
28
25
25
34
63
153 315 296 278 272 266 260 255 243 231 211 191 179 167 107
54
102
91
44
27
24
23
19
18
80 21
20
19
16
25
54
82
144 132 121 127 133 142 150 151 152 136 119 108
97
67
55
90
39
19
15
15
13
10
10
82.5 11
10
11
10
16
39
43
60
59
59
69
79
87
95
98
100
88
75
64
52
42
67
46
15
9
8
7
5
4
3
85
5
5
6
5
8
22
24
26
27
28
36
44
50
56
58
61
52
44
35
25
25
48
12
4
2
0
0
0
0
0
87.5
1
1
1
1
3
10
11
10
10
11
16
20
24
28
29
30
26
21
15
9
12
10
1
0
0
0
0
0
0
0
90
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Cree, Inc | 9201 Washington Avenue | Racine, WI 53406 Test Report Number: RESTL-2014-0017
Page 9 of 12 RESTL-R010 Rev D
NVLAP Lab Code 500089-0 Candela Tabulations (Continued) 0
5
15
25
35
45
55
92.5
0
0
0
0
0
0
0
60 62.5 65 67.5 70 72.5 75 77.5 80 82.5 85 87.5 90 0
0
0
0
0
0
0
0
0
0
0
0
0
95 105 115 125 135 145 155 165 175 180 0
0
0
0
0
0
0
0
0
0
95
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
97.5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
100
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
102.5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
105
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
107.5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
110
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
112.5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
115
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
117.5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
120
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
122.5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
125
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
127.5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
130
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
132.5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
135
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
137.5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
140
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
142.5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
145
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
147.5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
150
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
152.5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
155
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
157.5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
160
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
162.5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
165
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
167.5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
170
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
172.5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
175
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
177.5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
180
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Cree, Inc | 9201 Washington Avenue | Racine, WI 53406 Test Report Number: RESTL-2014-0017
Page 10 of 12 RESTL-R010 Rev D
NVLAP Lab Code 500089-0 Integrating Sphere Equipment List Description
Manufacturer
Model
Serial Number
2M Sphere
Everfine
2M
1004156T
CCD Array Spectrometer
Labsphere
MC-9801
98010360
Programmable AC Source
Adaptive
FC200
2280220
Power Analyzer
Chroma
66202
66202 0005018
Model
Serial Number
Goniophotometer Equipment List Description
Manufacturer
AC Power Source
Chroma
61602
616020002300
Type C Goniophotometer
LSI / UL
6440T
6440PN2028
Spectroradiometer
Gooch & Housego
770VIS/NIR
12415189
Power Meter
Yokogawa
WT210
91M945458
Test Methods Used: Title
Description
ANSI C82.77:2002
Harmonic Emission Limits- Related Power Quality Reqt’s for Lighting Equipment
CIE Pub. 13.3:1995
Method of Measuring and Specifying Color Rendering of Light Sources
CIE Pub. 15:2004
Colorimetry
IES LM-58:1994
Spectroradiometric Measurements
IES LM-65:2001
Single-Ended Compact Fluorescent Lamps – Life Test Performance
IES LM-79:2008
Electrical and Photometric Measurements of Solid-State Lighting Products
Reference Standard Used: Equipment
Description
2m Sphere
Tungsten Halogen Omni-Directional 75W Calibration Lamp, Serial Number F119
Type C Goniophotometer and Spectrometer
Tungsten Halogen Omni-Directional 500W Calibration Lamp, Serial Numbers 13C069. 13C070, 13C071. For color calibration of spectrometer, 13C074.
Cree, Inc | 9201 Washington Avenue | Racine, WI 53406 Test Report Number: RESTL-2014-0017
Page 11 of 12 RESTL-R010 Rev D
NVLAP Lab Code 500089-0 Disclaimers: This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of the federal government. The results contained in this report pertain only to the tested sample. This report shall not be reproduced, except in full, without written approval of the CESTL. Items marked with a single asterisk are not covered by the NVLAP accreditation. In the event that the recorded temperature is outside of 25 + 1˚C, this is considered a non-standard condition. ** In the event that testing is subcontracted, test results in this report marked with the symbol **, or noted as “Sphere” or “Integrating Sphere”, were performed by the subcontracted laboratory identified in the footer on the first page of this report. Subcontracted testing is strictly integrating sphere based. All other tests are performed using a Type C goniophotometer. The integrating sphere information in the equipment list, report items marked with **, or results specifically identified as “Sphere” or “Integrating Sphere”, are the actual equipment used, and test results produced, by the subcontracted laboratory when subcontracting is indicated on the cover page.
Additional Comments: The photos below are intended to show the orientation and fixturing/set-up of the units under test. These are critical to understanding the results of the test given the sensitivity of many products and measurement systems to orientation and set-up considerations, and also for reproducing the conditions of the test. Goniophotometer
Integrating Sphere
Cree, Inc | 9201 Washington Avenue | Racine, WI 53406 Test Report Number: RESTL-2014-0017
Page 12 of 12 RESTL-R010 Rev D