Preview only show first 10 pages with watermark. For full document please download

Retrofit Kit 4

   EMBED


Share

Transcript

Retrofit Kit 4 BlueRidge Technologies Project Part Number Ref. Data Sheet : Catalog Page 30 Overview Retrofit Kit (RK) replaces existing relay panel electronics. RK installation retains the original relays, line voltage wire, conduit, and enclosure reducing labor as well as material cost. Retrofit Kit 4 (RK4) is designed to convert existing relay panels which utilize 4-Wire relays. The kit includes a Controller, two 30-Relay Interface Boards (RIB), as well as two ribbon and two power cables. Each board is mounted on a single aluminum plate for installation. Features Compatible with : • MicroLite Panels (MLR-020) • Johnson Controls ILC Panels (JCI-ILC) • Touch-Plate Panels (3000-PL and 4000-PL) Retains relays, line voltage wire, conduit, and enclosure Control up to 60 relays BACnet MS/TP and N2 communication to BAS network Sub network for Capacitive Touch Stations (CTS-DDN) Install in less than 4 hours Available options: • LEXP Digital Input Expansion Card • PT4 4-Wire Relay Interface Pigtail General Specifications Construction: PCB’s mounted to 14ga aluminum plates Dimensions: Controller: 11.00”(279mm)H x 4.50”(113mm)W x1.56”(40mm)D RIB: 9.00”(229mm)H x 3.75”(94mm)W x 1.25”(32mm)D 14pin Ribbon Cable: 18”(457mm)L 20pin Ribbon Cable: 32”(812mm)L Power Cable: 18”(457mm)L Weight: 2lbs(1kg) Mounting: Panel back plate with self-tapping screws (not included) Operating Environment: 32-125°F (0-50°C), 20-95%RH, non-condensing Certifications Electronics meet or exceed IEC Level 3 CEC Title 24 Warranty Two (2) year limited manufacturer warranty from date of shipment (extended warranty optional). Controller Specifications Power In: 24VAC +/-10%, 30VA, 50-60 Hz Auxiliary Out: 24VAC Full Wave Rectified Digital Input: 24 two-wire inputs Software Configuration: Maintained, state change, momentary on/off, momentary on, or momentary off Jumper Configuration: 8 input segments, dry contact (N) or 24VDC externally powered (R) Wire Requirement / Maximum Length: 18AWG (Solid or Stranded) / Dry Contact 500’(152m) or externally powered 1,000’(304m) Analog Input: 6 three-wire 0-5VDC inputs Wire Requirement / Maximum Length: 18AWG (Solid or Stranded) / 250’(76m) BAS Network Specifications BACnet MS/TP Baud Rate: DIP switch selectable 9.6K, 19.2K, 38.4K, or 76.8K Device Profile: BACnet Advance Application Controller (AAC) Address Range: 1 – 99 selectable with rotary dials Unit Load: Full unit load, 32 devices per MS/TP segment N2 Baud Rate: DIP switch selectable 9.6K Address Range: 1 – 255 selectable with rotary dials and DIP switch BACnet MS/TP and N2 Topology: RS-485, 3 conductor (+, -, and shield), daisy chain wiring (no stars or t-taps) Wire Requirement / Maximum Length: Belden 8760 / 4000’(1216m) Points: See Application Guide and PIC Statement DDN Network Specifications Compatible with CTS-DDN and DDN devices. See data sheet for details. RIB Specifications RIB-A: 30 relay outputs, drives relays 1-30 RIB-B: 30 relay outputs, drives relays 31-60 Relay Output Rating: 24VDC Relay Output Compatibility: 1 3000-PL or equal per, no external power / switches Relay Output Connection: 3 pin header, keyed for PT4 4-Wire Relay Interface Pigtail connection Wire Requirement / Maximum Length: 18AWG / 50’(15m) Optional Equipment Specifications LEXP Specifications Description: Digital Input Expansion Card Digital Input: 32 two-wire inputs Software Configuration: Maintained, state change, momentary on/off, momentary on, or momentary off Jumper Configuration: 8 input segments, dry contact (N) or 24VDC externally powered (R) Wire Requirement / Maximum Length: 18AWG (Solid or Stranded) / Dry Contact 500’(152m) or externally powered 1,000’(304m) Dimensions: 6.00”(152mm)H x 4.50”(113mm)W x1.13”(29mm)D PT4 4-Wire Relay Interface Pigtail: Description:18”(457mm)L,18AWG, 3-wire Pin/Color Code: 1/Yellow, 2/Red, 3/Brown RIB Connection: Keyed 3pin plug-on connector Relay Connection: 4 Insulation Displacement Connectors (IDC), 2216AWG, UL Listed BAS BAS Router 20A 1θTerminations Controller Field Devices Satellite/Station Network 20A 1θ RIB-A Terminations 20A 1θ Field Devices Rotary Switch 10’s Baud Rate / Protocol Network DDNAddress Network Dip Switch Network Address Relay Panel (RP) Rotary Switch 1’s Relays 1-16 DDN Network Zone Control (ZC) ON 5 6 7 78 78 4 456 3 8 456 2 23 1 2 3 1 BT485 S B- A+ SW1 SW3 SW4 OVER AUTO DDN Network Retrofit Interior (RI) DDN Network 901 901 23 BAS (+) In BAS (-) In Satellite/Station Network Shield 20A 1θ Field Devices Field Devices 1 Relay Output 1 RIB-B Terminations 20A 1θ Telephone Line POTS Relays 17-32 Retrofit Kit (RK) Retrofit Kit 4 Relay OutputField 2 Devices 2 Relay Output 17 BACnet Telephone Override Module (BTOM) 1 2 Relay Output 18 BT485 3 4 3 4 Terminator Plug Satellite (if applicable) 20A 1θ www.BRTint.com : 800-241-9173 Blue Ridge Technologies® © 2012 Blue Ridge CTS-DDN International, LLC All Rights LVS Reserved. BRT-RK4-DS-V11.01 5 Technologies 6 5 OCC 6 Control CTS Override Controls (SC) Field Devices 20pin Ribbon Cable J26 LEXP RIB-A / RIB-B Relays 33-60 20A 1θ LEXP Port DDN Network N ZoneG Control 17 18 19 20 21(ZC) 22 23 24 17-24* 1-8 9-16 DI Jumper R R Satellite/Station Network N N 1-8* 24VAC(+) Power In 24VAC(-) Power In G 1 2 Satellite 10 11 12 13 14 15 16 G Control (SC) 3 4 5 6 7 8 9 Field Devices 20A 1θ Switch 1’s Rotary Field Devices 7 78 78 6 456 5 8 SW4 DDN Network OVER SW1 SW3 AUTO 1 2 3 BT485 S B- A+ Relay Panel (RP) Yellow Yellow* Black Red Blue 14pin Ribbon Cable LS5 OCC Original RR8*, RR9, 2R9, or HDR5P Relay / Wiring IDC (Insulation Displacement Connector) IP *The yellow wire (RIB connector Pin 2) is capped when using RR8 relays. BACnet MS/TP RIB-B Terminations 2 3 4 Retrofit Interior (RI)5 6 CTS-DDN 7 8 9 10 11 12 13 14 15 CTS-DDN (Capacitive Touch Station for RI/RK/RP) Internet LEXP Port R Relays 31-60 RO 1 1 AC OUT RCS 1 2 3 4 5 6 7 8 LVS LVS (Low Voltage Switch) / OCC (Occupancy Sensor) / LS5 (Light Sensor) IDC (2) P BACnet Telephone Override Module (BTOM) Field Devices CTS-DDN ON OFF S 20A 1θ Telephone Line POTS Retrofit Kit (RK) Terminations J26 LEXP 16 17 18 19 20 21 22 23 20A 1θ RO 2 Field Devices DDN Network RO 31 20A 1θ 1 Telephone Line POTS 3 P Retrofit Kit (RK) RO 32 2 4 BACnet Telephone Override Module 6 5 (BTOM) Field Devices LVS OCC 7 8 9 10 11 12 13 14 LS5 15 16 LVS (Low Voltage Switch) / OCC (Occupancy Sensor) / LS5 (Light Sensor) 17 18 19 20 21 22 24 23 24 25 26 25 26 27 28 27 28 29 30 IP BACnet MS/TP G 17 18 19 20 21 22 23 24 9-16 R N N 24VAC(+) Power In 20A 1θ 24VAC(-) Power In Field Devices Power Cable DDN Network AUX VAC Zone Control (ZC) Satellite CTS Control AI (Analog (SC) Input) / DI (Digital Input) / GND (Ground) *DI Jumper Position N(Dry Contact) / R(Externally Powered) CTS (Capacitive Touch Station) General Architecture P G DDN Network 20A 1θ Field Devices CN8 DDN Network Retrofit Interior (RI) (1) DDN NetworkPT4 3 4 5 6 7 8 9 10 11 12 13 14 15 16 G GND DI 1 DI 2 DI 3 DI 4 DI 5 DI 6 DI 7 DI 8 GND DI 17 DI 18 DI 19 DI 20 DI 21 DI 22 DI 23 DI 24 (1) Relay Panel (RP) DI 9 DI 10 DI 11 DI 12 DI 13 DI 14 DI 15 DI 16 GND Satellite/Station Network 20A 1θ Field Devices Terminations Pin 1 Pin 2 Pin 3 20pin Retrofit Kit (RK) Ribbon Cable Field Devices Yellow Red Brown Yellow CTS-DDN CTS-DDN (Capacitive Touch Station for RI/RK/RP) RIB Connector (A) IDC LVS 20A 1θ 29 Telephone Line P G POTS AC IN 1-8 R INPUT POWER 24VAC AC IN N G 1 2 Field Devices 16 20A 1θ Field Devices CPU Power LED Run LED CTS BAS 17-24 Router Satellite/Station DI Jumper Network 9-16* 20A 1θ 15 (A) DDN Network CTS (Capacitive Touch Station) DI Jumper 17-24* 20A 1θ DI Jumper Field Devices 1-8* 16 AUTO OVERRIDE Satellite Control (SC) RUN General Architecture 5VDC AI 6 AI 5 AI 4 AI 3 AI 2 AI 1 BAS GND 15 DDN Network Override Controls PWR 5V A6 A5 A4 A3 A2 A1 G 14 Internet Power LED 456 4 23 3 Zone Control (ZC) DDN/CAN 13 20A 1θ Field DevicesAUX OUT 901 901 2 23 1 Satellite/Station Network 24VDC 20A 1θ DDN Network(-) DDN FieldNetwork(+) Devices GND 14 PT5 Override Controls ON Terminator Plug (if applicable) 12 13 DDN Network Relays 1-30 Baud Rate / Protocol Network Address Rotary Switch 10’s Dip Switch Network Address IP 10 BACnet MS/TP RIB-A Terminations BAS Router Satellite/Station BT485 Network 11 RIB Connector Controller Terminations BAS20A (+) 1θ In (-) In FieldBAS Devices Shield 12 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 AI (Analog Input) / DI (Digital Input) / GND (Ground) *DI Jumper Position N(Dry Contact) / R(Externally Powered) BAS 11 CTS-DDN (Capacitive Touch Station for RI/RK/RP) DI 9 DI 10 DI 11 DI 12 DI 13 DI 14 DI 15 DI 16 GND GND DI 1 DI 2 DI 3 DI 4 DI 5 DI 6 DI 7 DI 8 GND DI 17 DI 18 DI 19 DI 20 DI 21 DI 22 DI 23 DI 24 DDN NetworkPT5 CTS CTS (Capacitive Touch Station) General Architecture 9 Retrofit Interior (RI) 24VAC(+) Auxiliary Out 24VAC(-) Auxiliary Out AUX VAC Internet 10 DDN Network Relay Panel (RP) INPUT POWER 24VAC DI Jumper 9-16* 20A 1θ 20A 1θ Field Devices Field Devices RELAYS 33-60 9 Power LED 1 2 3 4 5 6 7 8 Satellite/Station DI Jumper Network 7 8 LVS (Low Voltage Switch) / OCC (Occupancy Sensor) / LS5 (Light Sensor) CN2 Power LED Run LED RELAYS 1-32 5V 5VDC A6 A5 AI 6 BAS BASA4 Router A3 AI 5 A2 A1 AI 4 G AI 3 20A 1θ AI 2 AI 1 Field Devices 17-24 GND R Data Sheet : Catalog Page 31 7 8 CTS-DDN (Capacitive Touch Station for RI/RK/RP) CN1 CTS (Capacitive Touch Station) PWR 24VDC RUN DDN Network(-) General Architecture DDN/CAN DDN Network(+) GND LS5 30 BACnet TelephoneRO Override (2) (Relay Module Output) (BTOM) OCC LS5 LVS (Low Voltage Switch) / OCC (Occupancy Sensor) / LS5 (Light Sensor) PT4 Original Touch-Plate or MicroLite Relay / Wiring IDC (Insulation Displacement Connector) IP Internet Controller Terminations BACnet MS/TP Baud Rate / Protocol Network Address Rotary Switch 10’s BAS Router Dip Switch Network Address BAS Ordering Information BAS (+) In Rotary Switch 1’s 20A 1θ SW1 SW3 SW4 Devices A+ BT485 S BKit for 4-wire relays, 3000-PL orField equal, 60 RO, 24 DI, 6 AI AUTO OVER 3 4 5 6 7 8 901 78 78 901 2 456 1 456 ON 23 1 2 3 BT485 Description 23 BAS (-) In Part Number 20A 1θ Shield Field Devices BRRK4 20A 1θ Field Devices Satellite/Station Network Network Terminator Plug Kit for 4-wire relays, 3000-PL orDDN BRRK4-L equal, 60 RO, 56 DI, 6 AI, LEXP (Card,DDN Mounting Plate, and Ribbon Cable) Zone Control (ZC) Relay Panel (RP) Retrofit Interior (RI) (ifNetwork applicable) BRPT4 4-Wire Relays, 18 Inches, Includes Insulation Displacement Connectors Override Controls Satellite/Station Network DDN Network 24VDC DDN Network(-) 20A 1θ DDN Network(+) GND Field Devices PWR DDN/CAN RUN Satellite Control (SC) RELAYS 1-32 Power LED Run LED CTS 20A 1θ Telephone Line POTS 20A 1θ Field Devices CTS-DDN DDN Network Retrofit Kit (RK) BACnet Telephone Override Module (BTOM) Field Devices RO (Relay Output) / DI (Digital Input) / AI (Analog Input) LVS OCC LS5