Transcript
F650-CK In-motion check weighing indicator
Actual size F650-CK is a weighing indicator designed for in-motion check weigher. With high-performance filter to attenuate noise and vibration, stable and accurate weight measurement can be achieved. All necessary functions for check weighers like over/under evaluation, ranking or sorting, various weighing modes, conveyor controls, statistics, and so on are packed into this model. Implement H, L comparison
Rank division (5 grades)
Rank division (11 grades) Load cells Weight signal
Control signal Buzzer F650-CK
Sorter Warning light
F650-CK
In-motion check weighing indicator
High-performance filter to attenuate vibration Cut-off frequency for low-pass filter with steep property can be adjusted in fine increment for in-motion check weighers.Stable and accurate weighing can be achieved even in an environment with a lot of vibration.
Specifications Analog Section
Excitation voltage : DC5V±5% Output current: within 90mA Ratiometric method (Up to 6 load cells at 350Ω can be connected in parallel.) Signal input range : −0.3 to 3.0mV/V Zero adjustment range : −0.2 to 3.0mV/V Automatic adjustment by digital computation Gain adjustment range : Automatic adjustment by digital computation Accuracy Non-linearity : within 0.01%/FS ±1digit (when 3.0mV/V is input) Zero drift : 0.025μV/℃RTI Typ. Gain drift : 1ppm/℃ Typ A/D converter Conversion rate : 1000 times/sec Resolution : 24bit (binary) Theoretical calibration Equivalent input calibration : accuracy when theoretical calibration is performed : 1/1,000
Filter
Digital filter Low-pass filter
Moving average (common for all modes) : OFF, 2 to 999 times Variable : 2.0 to 10.0Hz
Display section
Display unit Weight display Unit Decimal place
TFT color LCD module 3.5inch (320×240dot) Display area : 71(W) x 53(H) mm ×53(H)mm 5-digits (signs: minus sign on the highest numerical digit) NONE, kg, t, g, N, or lb (selectable)
Waveform display Waveform can be constantly monitored.Since the effect of filter can be visually checked (simulated), the adjustment of filter settings can be performed easily.
Status display Setting section
Waveform display
The effect of filter can be checked visually (display waveform before and after the filter setting is changed).
Over/under evaluation and ranking functions Check if the weight is over or under the target weight, and/or sorting into preset grades or classes (sorting into 11 grades or classes at the most).
Useful weighing modes to improve efficiency and accuracy Auto sorting mode is useful when conveyor speed, size, and weight are not constant. Reduction of processing capacity can be prevented as zero adjustment can be performed during operation.
Detect the situation where two cartons are on the scale. Even if two cartons are on scale, weight of each individual carton will be weighed and judged (OK/NG).
Total Function
External
Setting method
Setting by analog touch panel operation (with a key click buzzer)Setting can be performed by external devices as well via RS-232C interface and so on. Setting value memory Initial values : F.RAM (nonvolatile RAM), other values : lithium-battery-backed-up C-MOS RAM Settings protection Setting operation can be prohibited to prevent changes by miss-operation (LOCK 1, LOCK 2, LOCK 3). Setting item ・Standard mode (COMP MODE SEL.: COMP): CODE/STANDARD/OVER/UNDER/UPPER/LOWER ・Standard mode (COMP MODE SEL.: RANK.1): CODE/BOUNDARY 0/BOUNDARY 1/BOUNDARY 2/BOUNDARY 3/UPPER/LOWER ・Standard mode (COMP MODE SEL.: RANK.2): CODE/BOUNDARY 0/BOUNDARY 1/BOUNDARY 2/BOUNDARY 3/BOUNDARY 4/ BOUNDARY 5/BOUNDARY 6/BOUNDARY 7/BOUNDARY 8/BOUNDARY 9/UPPER/LOWER ・Checker mode: CODE/TAKING MODE/TRIGGER MODE/TAKING COUNT/TAKING RATIO/EMPTY COUNT/NEAR ZERO/DIGITAL LPF /MOV. AVE. FILTER/GROSS RATIO/HISTOGRAM TARGET/HISTOGRAM RANGE ・State output: CODE/OUTPUT SEL. 0/OUTPUT SEL. 1※/OUTPUT SEL. 2※/OUTPUT SEL. 3※/OUTPUT SEL. 4※ ※Selectable from OUTPUT, COMP, NZ, TAKING, ERROR, LOWER, STAB, RUN ・Graph: CODE/GRAPHIC MODE/TRIGGER LEVEL/X END POINT/Y START POINT/Y END POINT/DRAWING WEIGHT/ PRE TRIG.VALUE/FRONT OF FILTER ・Result: CODE/AVE.WEIGHT/MAX.WEIGHT/MIN.WEIGHT/CNT.OF DATA/GEN.STAN.DEV./SMP.STAN.DEV./MAX. - MIN./LATEST DATA ・Comparison: COMP MODE SEL./STAND. CMP SEL./COMPLETE OUT T./NEAR ZERO COMP./HI/LO COMP. SEL./PRESET TARE WGT.1 /PRESET TARE WGT.2/HOLD SELECT ・Operation: MD (PERIOD)/MD (RANGE)/ZT (PERIOD)/ZT (RANGE)/INDICATE COLOR/BACKLIGHT LOW TM/BACKLIGHT ON TM/ AUTO ACCUMULAT./OUTPUT MODE/OUTPUT COMP. MODE/WGT CODE INPUT/ZT MODE/AUTO ZERO AVE./B4 FUNC. SELECT/TAKING SPEED ・Communication: COMM. MODE/BAUD RATE/LENGTH/PARITY BIT/STOP BIT/TERMINATOR/FLOW CONTROL/ SI/F OUT1 SELECT/SI/F OUT2 SELECT ・System: INITIALIZATION/LOCK1/LOCK2/LOCK3/PASSWORD/LANGUAGE/[GROSS/NET] KEY/[DZ] KEY/[TARE ON] KEY/ SELF CHECK DSP1/SELFCHECK DSP2/SELFCHECK MEM/SELF CHECK KEY/SELF CHECK EXT/SELF CHECK COM ・Calibration: ZERO CAL./SPAN CAL./EQUIV. CAL./BALANCE WEIGHT/MIN. SCALE DIV./NET OVER/GROSS OVER/UNIT DISPLAY/ DECIMAL PLACE/DZ REGULATION VAL.
Histogram display: Numbers of data for each 9 weight ranges are displayed. Two set of data out of the range are displayed as well. Weighing results: results are displayed for each code. Statistics: display statistics data stored on F650-CK. Display average weight, maximum weight, minimum weight, number of data, population standard deviation, sample standard deviation, difference between maximum and minimum, latest data. External output : OVER or RANK1 or RANK20/GO or RANK2 or RANK21/UNDER or RANK3 or RANK22/ NONE or RANK4 or RANK23/NONE or (10 points) External input : (10 points)
Interface
Conveyor control Control signal is sent out for controlling conveyor.Inmotion check weigher can be designed only with F650-CK.
Real-time statistic function In order to process statistics in real time, you can constantly check and monitor the variation and distribution of data.
0, 0.0, 0.00, or 0.000 (selectable) BUSY, GO, EMP, SMP, COMP, NZ, STAB
RANK5 or STROBE/OUTPUT SEL. 0/OUTPUT SEL. 1/ OUTPUT SEL. 2/OUTPUT SEL. 3/OUTPUT SEL. 4 CODE0/CODE1/CODE2 or KEY LOCK/Graph drawing/D/Z ON/TARE ON/TARE OFF/Accumulation command/ Measurement start/Measurement reset
・SIF: 2-wire serial interface ・DAV: D/A converter(voltage output) (option) ・232: RS-232C communication interface ・DAI: D/A converter(current output) (option) ・485: RS-485 communication interface (option) ・CCL: CC-Link interface (option) ・BCO: BCD parallel data output interface (Sink type)(option) ・ODN: DeviceNet interface (option) ・BSC: BCD parallel data output interface (Source type)(option) ※Only one option can be installed.
Option ・ISC: I/O source board General Operating voltage・Power consumption 100 to 240 Vac ±10 to 15% (50/60Hz) 18W max performance Operating conditions Operation temperature range: −10 to 40℃ Storage temperature range: −20 to +60℃ Humidity: 80%RH or less (non-condensing) Dimension・Weight 96(W)×96(H)×138(D)mm (Projections excluded) approx. 1.0kg Attachments AC power cable (voltage resistance: 125 Vac ) (3m)・・・ 1, Jumper cable・・・ 2, Mini screwdriver (when D/A converter option is installed) ・・・1 FCN series I/O connector (with cover)・・・ 1, Operation manual・・・1, BCD output connector (when BCO option is installed)・・・ 1 DeviceNet connector (with ODN option is installed) ・・・ 1, CC-Link connector (when CCL option is installed)・・・1 Optional CA372-I/O: cable with FCN connector at one-end 3m accessories CA600-BCDCNV: FCN connector 32p-57・36p cabtyre cable 0.3m CA81-232X: miniDIN-D-Sub9p cross cable 1.5m CAAC2P-B3: AC power cable 3m CAAC3P-CEE7/7-B2: AC power cable (voltage resistance: 250 Vac) 2m CN50: FCN series I/O connector (with cover) CN51: BCD output connector
CN55: FCN series I/O connector (with diagonal cover) CN60: circular DIN 8p connector for RS-232C CN71: CC-Link connector CN80: analog I/O connector terminal CND01: DeviceNet connector DTC2-PSL: case for F650 GMP96×96: rubber seal
Histogram display
External dimensions (Front)
Unit: mm (Side)
(Rear)
Panel cutout size Panel thickness
* Please note that the specifications and design described in this catalog are subject to change without notice due to product improvements.
Unipulse Corporation International Sales Department 9-11 Nihonbashi Hisamatsucho, Chuo-ku, Tokyo 103-0005 Tel: +81-3-3639-6121 Fax:
Headquarter: Technical Center: Nagoya Sales Office: Osaka Sales Office: Hiroshima Sales Office:
9-11 Nihonbashi Hisamatsucho, Chuo-ku, Tokyo 103-0005 1-3 Sengendainishi, Koshigaya, Saitama 343-0041 CK16 Fushimi Bldg 1-24-25 Sakae, Naka-ku, Nagoya 460-0008 Sumitomo Seimei Shin Osaka Kita Bldg 4-1-14 Miyahara, Yodogawa-ku, Osaka 532-0003 Funairi Reiku Bldg 9-20 Funairihonmachi, Hiroshima 730-0843 Rev.1.02 2014 NOV.